100% found this document useful (3 votes)
2K views69 pages

Operation Manual For XD-D12B Transceiver

This document provides operation and maintenance instructions for the XD-D12B 125W HF Digitalized Anti-jamming Transceiver. It describes the purpose, configuration, functions, specifications, installation, operation, troubleshooting, and storage of the transceiver system. The system consists of the XD-D12B transceiver, an automatic antenna tuner, power supply, antennas, handset, and cables. The manual guides the user on how to properly operate and maintain the transceiver to obtain optimal performance and prolonged system life.

Uploaded by

Jose Simoza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
2K views69 pages

Operation Manual For XD-D12B Transceiver

This document provides operation and maintenance instructions for the XD-D12B 125W HF Digitalized Anti-jamming Transceiver. It describes the purpose, configuration, functions, specifications, installation, operation, troubleshooting, and storage of the transceiver system. The system consists of the XD-D12B transceiver, an automatic antenna tuner, power supply, antennas, handset, and cables. The manual guides the user on how to properly operate and maintain the transceiver to obtain optimal performance and prolonged system life.

Uploaded by

Jose Simoza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 69

XD-D12B 125W

HF Digitalized Anti-jamming Transceiver

Operation Manual

2012.10
Contents

1 GENERAL DESCRIPTIONS.................................................................................................................... 3

1.1 PURPOSE........................................................................................................................................... 3
1.2 CONFIGURATION............................................................................................................................... 3
1.3 SYSTEM CONNECTING FIGURE........................................................................................................ 3
1.4 INSTALLATION OF THE ANTENNA.................................................................................................... 4
1.5 FUNCTIONS....................................................................................................................................... 5
1.6 OPERATING METHOD OF THE FUNCTIONS......................................................................................... 6
1.7 THE SYSTEM CAN BE MATCHED WITH THE FOLLOWING ANTENNAS.................................................. 6

2 MAIN TACTICAL TECHNICAL SPECIFICATIONS......................................................................... 6

2.1 GENERAL PERFORMANCE REQUIREMENTS :................................................................................. 6


2.2 ELECTRIC PERFORMANCES OF RECEIVER :................................................................................. 7
2.3 ELECTRIC PERFORMANCES OF TRANSMITTER :......................................................................... 7
2.4 AUTOMATIC CONTROL COMMUNICATION PERFORMANCES :...................................................... 7

3 DESCRIPTION ON THE FUNCTION INTERFACES OF THE SYSTEM...................................... 9

3.1 DESCRIPTION ON THE LAYOUT ON THE FRONT PANEL OF THE SYSTEM.......................................... 9


3.2 DESCRIPTION OF THE LAYOUT ON THE BACK PANEL OF THE SYSTEM.......................................... 12

4 SYSTEM INSTALLATION................................................................................................................ 13

4.1 CHECKING BEFORE INSTALLATION :......................................................................................... 13


4.2 INSTALLING THE SYSTEM :.................................................................................................... 14
4.3 CHECKING AFTER THE INSTALLATION:..................................................................................... 14
4.4 ADJUSTMENT AFTER THE INSTALLATION :............................................................................. 14

5 OPERATING THE SYSTEM................................................................................................................ 14

5.1 FIXED-FREQUENCY COMMUNICATION MODE :..................................................................... 16


5.2 AUTOMATIC CONTROLLING COMMUNICATION MODE :......................................................... 22
5.3 REMOTE CONTROL MODE :.................................................................................................... 38

6 USING NOTICING ITEMS : .................................................................................................... 39

7 COMMON MALFUNCTIONS OF THE DEVICE AND MAINTENANCE : ...................... 39

7.1 POWER SUPPLY INSPECTION AND ACCESSORIES INSPECTION :.............................................. 39


7.2 INSPECTIONS AND REPLACEMENT OF THE PARTS IN EACH OF THE UNITS :.......................... 40
7.3 JUDGMENT AND REPAIR OF THE FAMILIAR FAILURE OF THE SYSTEM :.................................. 40
7.4 SIMPLE FAILURES ARE SEARCHED AND REPAIRED URGENTLY :.......................................... 42

1
7.5 STORAGE AND MAINTENANCE IN STOREHOUSE :................................................................. 43

8 REQUIREMENT AND METHOD OF PACKING, TRANSPORTING AND STORING THE PRODUCT


FOR A SHORT TIME: .................................................................................................................... 47

8.1 PACKING AND TRANSPORTING.................................................................................................... 47


8.2 STORING REGULATIONS :........................................................................................................ 47
8.3 REQUIREMENTS OF THE STOREHOUSE :................................................................................. 48

9 OPERATION INSTRUCTION FOR DATA TRANSMISSION SOFTWARE.............................. 48

9.1 INSTALLATION OF SOFTWARE:........................................................................................................ 48


9.2 SYSTEM CONNECTION:................................................................................................................ 48
9.3 OPERATION OF SOFTWARE:............................................................................................................ 48

10 NOTICING ITEMS........................................................................................................................... 55

11 Y130A POWER SUPPLY.................................................................................................................... 56

11.1 BRIEF INTRODUCTION................................................................................................................ 56


11.2 OPERATION CONDITION................................................................................................................ 56
11.3 MAIN TECHNICAL SPECIFICATIONS............................................................................................ 56
11.4 DIMENSION, WEIGHT, AND COOLING MODE............................................................................. 58
11.5 WORK PRINCIPLES........................................................................................................................ 58
11.6 THE SKETCH MAP AND INTRODUCTION FOR THE FRONT AND BACK PANEL.............................. 60
11.7 DISPLAY AND SETTING................................................................................................................ 62
11.8 INSTRUCTION ABOUT INSTALLATION, OPERATION AND DISASSEMBLE...................................... 64
11.9 SOLUTION FOR COMMON FAULTS................................................................................................ 65
11.10 MAINTENANCE METHOD............................................................................................................ 66
11.11 PACKAGE, TRANSPORTATION AND STORAGE............................................................................. 66
11.12 Open-case Inspection Item........................................................................................................ 66

2
1 General Descriptions
This operation manual has mainly described the features, the purposes, the functions, the main
technical specifications, the operating principles, the installing methods, the maintenance, the
shipping and storing methods, the operating process and methods of the functions of Model XD-
D12B 125W HF Digitalized Anti-jamming Transceiver. Before you operate the system, you had better
read the operation manual carefully because it will guide you to operate Model XD-D12B 125W HF
Digitalized Anti-jamming Transceiver correctly so that you can obtain the best operating benefits
and the operating life of the system will be prolonged.
1.1 Purpose
XD-D12B 125W HF Digitalized Anti-jamming Transceiver can be used as the ground fixed
station and as the vehicle-borne transceiver for performing the mobile communication with the high
authority departments.
1.2 Configuration
The system consists of the following units :
a) XD-D12B 125W HF Digitalized Anti-jamming Transceiver------------------- 1 set ;
b) ZTX-4 automatic antenna tuner ------------------------------------------------ 1 set ;
c) Y130A 24V DC power supply ---------------------------------------------------- 1set;
d) Antennas :
1) 15m slant antenna------------------------------------------------------------ 1 set ;
2) 2×22m dipole antenna----------------------------------------------------- 1 set ;
e) OSB-3Q handset telephone transmitter ---------------------------------------- 1 set ;
f) Cables :
1) Data-transferring cable----------------------------------------------------- 1 set ;
2) 6m RF coaxial cable-------------------------------------------------------- 1 set ;
3) Y130A24VD DC power supply input cable (220V)-------------------1 set;
4) Y130A24VD DC power supply output cable---------------------------1 set;
g) Operating manual and fuse------------------------------------------------------ 1 copy.
1.3 System connecting Figure

Y130A24VD DC power

power supply output cable antenna

Data-transferring
data-transferring RF cable
terminal XD-D12B(24V) ZTX-4 automatic antenna tuner
cable
Figure 1.1
Before you operate the system, you should connect all the devices in the system as the Figure

3
above shown. When matched with antenna and connected with automatic antenna tuner, XD-D12B
can perform communication in long distance ; when connected with data terminal , you can
transfer data through data-transferring cable.
1.4 Installation of the Antenna
1.4.1 Vehicle-borne Antenna
There are lots of kinds of antennas for mobile communication. When you install the antenna,
make sure there is enough distance between the antenna and the mobile so that the wireless signal
can radiate. Additional, the wire connecting the output of the antenna tuner and antenna should be
short.
1.4.2 15m Slant Antenna
One end of the antenna is going to be connected to the automatic antenna tuner, and the other
is going to be pulled upwards. When you install the antenna, you should pay attention to that there is
an angel between the antenna and the ground. As the Figure 1.2 below shows :

Figure 1.2
1.4.3 44m Dipole Antenna
XD-D12B can be used as fixed transmitting-receiving set. Using 44m dipole antenna, the set can
make long distance communication. One end of the antenna is connected to the automatic antenna
tuner, and the other is connected to the ground of the tuner. The dipole antenna should be installed
regularly. It’s two legs must be horizontal, and it’s feedback rope should be vertical to the legs. The
direction of the biggest radiation of the antenna is vertical to the legs of the antenna. See the Figure
1.3 below :

4
Figure 1.3
1.5 Functions
1.5.1 Communication Modes
The system has the functions of the fixed-frequency operating mode and automatic control
communication mode.
1.5.2 Operating Types
The system can perform the operations of the analog voice, the digital voice, the data stream
and others.
1.5.3 Functions of clearing up the pulse interference
1.5.4 Self-Built–in Test Equipment (BITE) :
a) During being operated, the manual operation starts the Self-BITE.
b) The system has the function of self-testing the inner modules and of displaying the test
results.
1.5.5 Programmable Function of the System :
The software programs can be filled or modified via the outside filling gun.
1.5.6 The system has the function of presetting the parameters:
The system has the function of presetting the parameters. Although the system is powered
off , the preset information and parameters can be kept in the system for more than 5 years.
1.5.7 Short Message Function :
a) The system has the functions of editing, transmitting and receiving the short messages.
When a message is received, there is a prompting sound and pattern displayed on the displaying
window.
b) 100 common use military words have been preset in the system.
c) 10 newest short messages that are just received or transmitted already can be separately

5
stored in the system.
1.5.8 Display :
The system adopts the displaying method of the English character.
1.6 Operating Method of the Functions
The system adopts the English character display, the quick button and the drawing-down
manual to perform the simple operation and all the controlling functions.
1.7 The system can be matched with the following antennas
a) 6m HF whip antenna ;
b) 15m slant antenna ;
c) 44m dipole antenna;
d) length alterable antenna;
e) broad antenna ;

2 Main Tactical Technical Specifications


2.1 General Performance Requirements :
2.1.1 Frequency range : 1.6000MHz ~ 29.9999MHz
2.1.2 Frequency space : 100Hz
2.1.3 Frequency reliability :≤ 1×10-6/d
2.1.4 Relative maximum frequency error : ±30Hz
2.1.5 RX/TX converting time :≤ 200ms
2.1.6 Communication modes : Fixed-Frequency mode ; Automatic controlling
communication ; Remote control mode
2.1.7 Operation types : Analog voice ; Digital voice ; Data stream ; Data transmit
2.1.8 Modulation modes : USB , LSB , CW
2.1.9 Presetting communication parameter group : 10 groups ; The system has the manual
mode in the Fixed-Frequency operation.
2.1.10 Continuous Operation Capability of the System:
a) The main set is operated at the RX/TX converting time : 9min/1min. The continuous
operating time is not less than 24h.
b) The continuous transmitting time of the main set is not less than 15min.
2.1.11 Tuning Capability of the Automatic Antenna Tuner
a) Voltage standing wave ratio (VSWR) :≤ 2
b) Tuning time :≤ 8s
2.1.12 Power supply :
Rated voltage 24V DC
2.1.13 Reliability :
Mean time between failures (MTBF) (θ 1 ) : 1200h

6
Mean time to repair (MTTR): 20min
2.1.14 Environment condition :
a) Operating temperature: -20℃~ 55℃
b) Storage temperature: -25℃~ 65℃
c) Relative humidity : 95% (+40℃)
2.1.15 Dimension of the transceiver : 280 mm×108 mm×345 mm
2.1.16 Weight of the transceiver : ≤ 9.2kg
2.2 Electric Performances of Receiver :
2.2.1 Basic sensitivity :
a) SSB voice :≤ 1.0μV
b) USB CW:≤ 0.5μV
2.2.2 IF Selectivity :
a) 3dB bandwidth :≥ 2.7kHz
b) 40dB bandwidth :≤ 4kHz
2.2.3 Audio response :
Variation within the range 300Hz~ 3000Hz:≤ 3dB
2.2.4 Total distortion coefficient :≤ 5%
2.2.5 Audio output power : 125mW
2.2.6 IF rejection ratio :≥ 90dB
2.2.7 Imagine rejection ratio :≥ 90dB
2.2.8 AGC Character : input signal 2μV~ 20mV, audio output variation ≤ 3dB
2.3 Electric Performances of Transmitter :
2.3.1 Output power :
a) Low power : 50W allowing the change 1dB
b) High power: 125W allowing the change 1dB
2.3.2 Generated level in the relative audio inter-modulation :
1.6MHz ~ 29.9999MHz :≤ -25dB
2.3.3 Side band rejection:≤ - 50dB
2.3.4 Carrier rejection :≤ - 50dB
2.3.5 Voice line input level : 3mV ~ 20mV
2.3.6 Power consumption of the transmitter :≤ 480W
2.4 Automatic Control Communication Performances:
2.4.1 automatic control communication specifications :
a) Setting up the network :
1) Single set address : 200(100~ 299)
2) Network address : 20(300 ~ 319)
3) Group address : 10(600 ~ 609)

7
4) Whole calling address : 1(900)
b) Calling: Single call, group call, network call and whole call
c) Number of the preset channels : 256
d) Any time dynamic change of the scanning frequency ; The system can detect the preset
frequency collection in the active way and passive way.
e) Function of the operation type of the called transceiver can automatically track the
calling transceiver :
The system can select the excellent anti-interference mode according to the operation types
that are selected by the user and establish the reliable and quick automatic link establishment (ALE)
so that the called transceiver can automatically track the host calling transceiver.
f) The system has the function of protecting the automatic link establishment, the frequency of
the automatic link establishment (ALE) is separated from the communication frequency.
g) After the automatic link establishment ( ALE ) has been set up, the called system receives
the operation from the host calling system automatically. And according to the present error code
rates or the communication and the interference situations, the operation of the system can be
converted from the Fixed-Frequency communication to the Frequency-Hopping communication or
from the Frequency-Hopping communication to the Fixed-Frequency communication via the manual
operation.
h) After the Fixed-Frequency automatic link establishment (ALE) has been established, the
system can detect the preset operating channels and re-establish the new automatic link
establishment (ALE) in the excellent channels. After the Frequency-Hopping automatic link
establishment (ALE) has been established, the system can detect the Frequency-Hopping operating
channels and eliminate the interference channels.
2.4.2 Frequency-Hopping Character :
a) Frequency-hopping rate : 5Hops/s, 10Hops/s , 20Hops/s
b) Operation types: the digital voice , SMS and the data transmission
c) Frequency-hopping Bandwidth : Frequency table generated automatically by the center
frequency : 128kHz, 256kHz, 512kHz.
d) Channel converting time :≤ 2ms
e) Network establishing function : The system has the function of establishing the
asynchronous network and the late entering network.
f) Preset frequency-hopping secret key number : 100 groups
2.4.3 data transmission Communication Feature :
a) Clarity data:
1) The operation of the clarity data is suitable for the Fixed-Frequency data link and
Frequency-Hopping data link that are established for the single call, the group call, the network call
and the whole call in the automatic controlling communication mode as well as the data transmitting

8
mode at the lowest velocity operation in the Fixed-Frequency communication.
2) Fixed-Frequency transmitting rates :
75bps, 150bps , 300bps , 600bps , 1200bps , 2400bps ;
3) Frequency-Hopping transmitting rates :
75bps, 150bps , 300bps , 600bps , 1200bps ;
b) Automatic Error Request Equipment (ARQ) : The operation of the no error (ARQ) data is
suitable for the Fixed-Frequency no error (ARQ) data link and Frequency-Hopping no error (ARQ)
data link that are established for the single call in the automatic controlling communication mode.
2.4.4 Digital Voice Communication:
a) The digital voice communication is suitable for the single call , the network call , the
group call and the whole call in the automatic controlling communication mode after the fixed-
frequency digital voice link and the frequency-hopping digital voice link have been established. And
it is suitable for the digital voice operation in the fixed-frequency communication mode.
b) Error code gate threshold : When the error rate does not exceed 1×10-2 , the word
readability is more than 80% ;
c) Information ending : After the ended information has been received , the
synchronization operation of the system is lost.
d) The receiving system can automatically receive the digital voice operation.

3 Description on the function interfaces of the system


3.1 Description on the layout on the front panel of the system
The front panel of the system mainly consists of: audio socketⅠ , audio socketⅡ , 8Ω
trumpet , data socket , display window , key board , volume potentiometer with
switch and others
The front panel viewing diagram is please seen in the following Figure 3.1 :

9
Figure 3.1: Front Panel Viewing Diagram
3.1.1 Power supply switch/Volume potentiometer :
The power supply switch is used to control the switching ON / OFF of the power supply of
the system ; The volume potentiometer is used to adjust the high volume or low volume of the
earphone.
3.1.2 Displayer :
The displayer of the system can display the information of all the operating states.
3.1.3 Key board :
The key board is used to set and change all the operating parameters and the operating states
of the system.
3.1.4 Audio Socket :

Figure 3.2 Audio Socket


There are 2 same types of the audio sockets on the right side of the front panel whose pins are
in parallel connected together. These two sockets are used to out-connect the transmitter and receiver
set, the CW key and other audio devices. The pins of the sockets are seen in Figure 3.2. ; The
definitions of the pins are seen in Table 3.1.
Table 3.1 The definitions of the pins of the audio socket and the socket:
Pin Name Output/
No. Function Character Remark
No. (No.) Input
1 1 GND Grounded
Microphone audio
2 2 MIC Input
input
Earphone audio
3 3 PHN Output
output
Power supply +13.8V/20m
4 4 PWR Output
output A
CW transmitting Low level
5 5 CW-PTT Input
key PTT is effective
6 6

10
Low level
7 7 PTT Voice TX key PTT Input
is effective
3.1.5 Data Socket :
This socket is used to connect the outside data terminal. At the same time, it is also the socket
for the programs to be loaded, the remote control measurement and the security (crypto) device.
The pins of the socket are seen in Figure 3.3 ; The definitions of the pins are seen in
Table3.2.

Figure 3.3
Table 3.2 : Definitions of 19-pin Data Socket
Pi
No n OU
Name Features Remark
. N T/IN
o.
1 A GND GND
For nearby
2 B YKTXD External Data RXD OUT
remote control
For nearby
3 C YKRXD External Data TXD IN
remote control
For Data
4 D TXDB External Data TXD IN
communication
For Data
5 E RXDB External Data RXD OUT
communication
For nearby
6 F RTSB Sending Request IN
remote control
For Data
7 G CTSB TXD Clear OUT
communication
For Data
8 H CDB Carrier Checking OUT
communication
9 J 13.8V 13.8V OUT ≤20mA

11
10 K VPTT IN
11 L TDO Test Data OUT OUT For testing
12 M 3.3V
For Data
13 N TCB External CLK IN
communication
For built-in
14 P BMI/O Parameter IN IN
encrypt device
15 R RAF Audio OUT OUT
16 S TAF Audio IN IN
17 T TCK Test CLK IN For testing
18 U TMS Test Mode Select IN For testing
19 V TDI Test Data In IN For testing

When the system data socket is connected with the PC (computer) to perform the data
communication , the connecting relationship of the data cables of the system with the data cables
of the PC (computer) is seen in Table 4.3.
Table 3.3 : Connecting Relationship of Data Cables of System with the Data Cables of the PC
(computer)

Data interface 9-pin (Computer Serial


Definitions
(Equipment) Port)
F 7 RTS
E 2 RXD (Terminal RX)
D 3 TXD (Terminal TX)
A 5 GND
G 8 CTS
Note 1 : 19-pin Plug of Data Interface: YLH26N1219J03(Φ8)(Reference) ;
Note 2 : When transmitting, RTS is set to the effective position (high level). After CTS is
effective(high level) , the data can be transmitted via TXD.
3.2 Description of the layout on the back panel of the system
The back panel of the system consists of power input socket , RF input/output socket , K
interface , accessorial socket , grounding post , fuse and others.
The back panel view diagram is seen in the following Figure 3.4

12
Figure 3.4 the
back panel view diagram
3.2.1 Power input socket
Connect the “power input socket” and DC output socket of Y130A (24V) through power
supply’s output wire so that the whole system can be electrified with 24V DC.
3.2.2 RF input/output socket
The socket is “RF input/output”, meanwhile, it provides power supply for automatic antenna
and communicates with XD-D12B. When operating XD-D12B, you should connect this socket to RF
socket of automatic antenna tuner with RF cables which have been provided already.
3.2.3 Accessorial socket

Pin OU
No. Name Features Remark
No. T/IN
1 A MIC+ 220mV,150Ω IN
2 B +24V OUT 400mA
3 C +24V OUT 400mA
4 D +13.8V OUT 10mA
5 E NC
6 F GND GND
7 G MIC- 220mV,150Ω IN

13
8 H RAF 220mV,150Ω OUT
9 J PTT 0V/3.3V IN
10 K NC

3.2.4 Grounding post


The grounding post is used for the 125W system to be grounded in order to enhance the
communication distance or to be grounded together with automatic antenna tuner.
3.2.5 Fuse
The system adoptsφ6×25 fuse that endures 25A, which protect the system from big current.

4 System Installation
4.1 Checking before Installation:
Check if the transceiver and the accessories are all ready and good.
4.2 Installing the System :
4.2.1 Installing the battery group :
The volume potentiometer switch on the front panel should be set to Position “OFF”. The
conduct post of the transceiver and the positive post “+” and the negative post “-” should be
inosculated with the corresponding positions of the battery group. The moveable fibulas of the
battery group should be strictly fixed with the fixing clasp of the transceiver.
4.2.2 Installing the Antennas :
According to the different communication distances of the system, the different antenna can
be selected and connected with the antenna socket. The antenna types can be set via the key MENU.
4.2.3 Installing the Automatic Antenna Tuner
Connect the “RF input/output” socket of XD-D12B system and “RF input” of automatic
antenna tuner with RF cables.
4.2.4 Installing the Accessories:
The system can be connected with the earphone set, the handset, the Morse key and other
accessories. When the system is operated, they should be connected into the audio sockets on the
front panel and turned clockwise as well as clipped into the sockets.
4.2.5 Grounding:
If the communication distance of the system is expanded or the system is matched and
connected with the 125W system, it is necessary to ensure that the system should be well grounded.
4.3 Checking after the Installation :
After the installation is ended, it should be carefully checked if the antenna, the earphone set
(or the Morse key), the battery group and others have been well and correctly installed.

14
4.4 Adjustment after the Installation :
After the installation has been correctly checked and the power supply switch is powered
on , the displayer displays the present operating state of the system, there is some noise in the
earphone set and the system is set to the position of “Fixed-Frequency”. When the button “PTT” is
pressed, the TX voice should have the power indication. The other items can be checked according
to the “Operating Methods” as well as all the functions are normal. When the key CHK is
pressed , the system starts to check each of its modules in the system if each of its modules is
normal. If the unconventionality is found, the power supply should be immediately turned off and
the system should be sent to the special service center to be repaired.

5 Operating the System


After the cables, the antenna and the microphone set(the Morse key or other audio
equipment)have been connected well, the operation of the system can be performed. There are 16
buttons on the keyboard of the system. In the different operating states, there are the different
definitions. The names and positions of the buttons on the keyboard are seen in Figure 5.1.

Figure 5.1
Buttons Digit (0 ~ 9): The digit buttons (0 ~ 9) are used to edit the parameters of the
frequencies, the channels, the addresses and the time.
Buttons Alphabet (A~ Z) : The alphabet buttons (A ~ Z) are used to edit the words,
the characters and the interpunction.
Buttons ↑ , ↓ : The upward /downward moving cursor buttons are used to change the
numerical values at the positions and select the parameter group.
Buttons ← , → : The leftward/rightward moving cursor buttons are used to move the
cursor or enter the operation of manually programming the frequencies in the Fixed-Frequency
manual channels.
Button MENU : The MENU button is used to preset and program the parameters as well
as the frequencies of the system.

15
Button ENTR : The ENT button is used to ENT the selected items. When the icon of the
envelope is displayed, the system enters the contents of the unread short messages.
Button MODE : The mode button is used to select the operating mode of the system.
When the system is operated in establishing the link state of the automatic controlling
communication, the mode button is used to interconvert the operation between the Fixed-Frequency
link and the Frequency-Hopping link. When the system is operated in establishing the Frequency-
Hopping link, the mode button is used to Frequency-Hopping fixed call.
Button OPRT : The operation button is used to select the analog voice, the digital voice,
the data transmit and the ARQ operation.
Button SQUELCH : The squelch button is used to select the squelch mode.
Button CHK : The CHK button is used to start the self-built-in test equipment operation.
Button POWER : The power button is used to select the power grade.
Button DETECT : The detect button is used to detect the channel quality or to tune the
antenna when the system is operated in the frequency- fixed operating state.
Button RATE : The hop seed button is used to change the frequency- hopping velocity.
Button LATE ENT : The late enter button is used to request the late enter network or to
guide the late enter network.
Button SCAN : The scan button is used to enter the operating state of setting the calls when
the system is operated in the scanning state. When the system operated in the state of establishing
the link, the link is removed so as to return to the scanning state.
Button MSG : The short message button is used to drive the short message function of the
system.
After the system is powered on, the system displays the starting up MENU like Figure 5.2. A
moment later, the system displays the initial state of the operating mode last time when the system is
powered off.

Loading······

Figure 5.2
The system has 3 operating modes :
Fixed-Frequency communication(NOR) ;
Automatic controlling communication(AUTO) ;
Remote control mode
5.1 Fixed-Frequency Communication Mode:
If the system stayed in the Fixed-Frequency operating mode while the system is powered off
last time , the system stays in the Fixed-Frequency receiving state while the system is powered

16
on at present. If the system stay in the other communication operating mode , the button MODE
should be pressed and the menu Com-mode Set is popped, The buttons↑ ,↓ can be used to select
Fixed-freq and the button ENTR is pressed to ENT this operation. A moment later, the system is
changed into the Fixed-Frequency communication mode as shown in Figure5.3

Figure 5.3

Figure 5.4
●1 Squelch mode displaying section : Squelch displays SQU ; falling squelch
displays DP ; Remove squelch display NB. These modes can be combined.
●2 Operation displaying section : The analog voice operation displays APV ; The digit
voice operation displays DPV ; The data operation displays DATA ; The no-error data
operation displays ARQ (But the Fixed-Frequency operation has not this operation.)
●3 Channel displaying section : 00 ~ 99 expresses the pre-storing channel of the Fixed-
Frequency communication of the system.
●4 RX/TX power displaying : According to the grade of RX/TX power, this section
displays corresponding color.
●5 TX power grade displaying section : When the system is operated in the 125W power
output, it expresses that the system transmits PEP 125W ;
●6 Time displaying section : The system displays the present time. The time format is for
24 hours.
●7 Frequency displaying section : The unit of the frequency used in the present channel is
MHz.
●8 Communication mode displaying section : Communication Mode at present can be
changed by pressing the button MODE. NOR expresses that the system is under Fixed-Frequency

17
mode ; AUTO expresses that the system is under automatic controlling communication mode.
●9 Modulation mode displaying section: USB means the upper side band voice ; LSB
means the lower side band voice ; CW means the upper side band CW ;
●10 Antenna tuning state displaying section : this section displays the tuning state of the
frequency of present channel. FALL expresses that the system fail to tune up. OK expressed that the
system manages to tune up.
●11: Impedance displaying section : 8Ω expresses that the impedance of RX voice 8
ohm ; 600Ω expresses that the impedance of RX voice 600 ohm.
5.1.1 Frequency program and parameter set of the Fixed-Frequency communication.
When the system is operated in the receiving state of the Fixed-Frequency communication and
the button MENU is pressed, the interface is displayed the interface MENU SELECT as shown in
Figure 5.5. When the button MENU is pressed, the system returns to the previous operating state.
The buttons ↑ ,↓ are used to select the moving cursor.

Figure 5.5
The cursor is moved to select Frequency Set. The button ENTR is pressed to display the
information as shown in Figure 5.6. The channel number of the Fixed-Frequency communication of
the system has 100 pre-stored channels (Channel number00 ~ 99). The buttons ← ,→ are used
to move the cursor and the buttons↑ ,↓ or the button Digit are used to change the values where
the cursor stays. The button MENU is pressed to return to the previous operating state.

Figure 5.6
a) Channel frequency program of the Fixed-Frequency communication :
Under the interface of Figure 5.4, frequency of present channel can be changed, but the
RX/TX operation is in the synchronous frequency mode.
The button ENTR is pressed , the cursor shows up. The buttons ← ,→ , Digit are used
to move the cursor and change the values where the cursor stays. Press the button ENTR again, the
frequency is stored into the system. The button PTT or detect should be pressed in order to store and

18
tune this frequency.
If the system selects to set the RX/TX operation in the asynchronous frequency mode (see the
Figure 5.6.), the buttons ← , → , Digit are used to set the RX/TX frequencies of different
channels. After the receiving frequency has been preset and then the transmitting frequency should
be preset, the button ENTR is pressed , the RX/TX operation in the asynchronous frequency
mode is stored into the system. The cursor is automatically jumped to the digit place 0. The button
PTT should be pressed in order to store and tune this RX/TX asynchronous frequency.
b) Universal Parameters Preset :
The cursor is used to select the System Set and the button ENTR is pressed to display the
information as shown in Figure 5.7. After the button MENU has been pressed, the system returns to
its previous operating state. When the buttons ↑ , ↓ are pressed to move the cursor, the
following items can be selected : Antenna Select , Reset Default , Self-test
Set , Brightness Set , Date &Time , Data-trans Speed , Com speed , Dte
Mode , Int , CRE , CRE Set , D Voice. When button ENTR is pressed, the system
enters the operations of setting various parameters. The universal parameters are the basic
parameters of the system. The universal parameters can be set in all the communication modes. The
descriptions of the universal parameters can be seen in Table 5.1.

Figure 5.7
Table 5.1 : Universal Parameter Table
Parameter Default Clear up
Setting Range Description
Name Values Values
Whip Antenna, Slip
Antenna Antenna, Dipole Dipole
/
Selection Antenna, Broadband Antenna
Antenna
Inefficacy
Reset Default No, Yes No
present
Inefficacy
Self-test set No, Yes No
present
Date & Time / Present date, /

19
time

Data-trans
75 ~ 2400 1200 /
speed

75 ~ 9600 ;
Com Speed 9600 slip /
slip

Asynchronous, Asynchrono
Dte Mode /
Synchronous us
S : Short
No Interlace Mode, Short Interlace
Int Mode Short Interlace Mode, Interlace Mode; L : /
Long Interlace Mode, Mode Long Interlace
Mode
CRE No, Yes No

5.1.2 Display and Operation of Fixed-Frequency Communication :


When the system stays in the receiving state of the Fixed-Frequency communication, the
buttons ↑ ,↓ are pressed to modify the present using channel(manual channels 00 ~ 99).
When the button DETECT is pressed, the frequencies in the present channel are tuned. When
the frequencies are tuned, the word Being Tuned is displayed and a tone is accompanied. When the
tuning operation is not successful, the word FALL is displayed. If the tuning is successful, the
communication can be performed in the present channel.
When button MENU is pressed , the interface MENU is displayed.
When the buttons RATE,LATE ENT, SCAN are pressed, they are not effective.
When the button MODE is pressed , NOR , AUTO And remote control mode selected
is the present communication mode of the system.
The button OPRT is pressed, the interface Operation displaying section displays
APV , DATA , DPV alternately. And the operation selected is the present operation the
system works at.
The button Squelch is pressed, This Squelch mode is displayed in the interface, as shown in
the Figure 5.8. Press the button MENU, the interface returns to the previous operating section. You
can press the button↑ ,↓ to choose the squelch type. Press the button ENTR, and there is a symbol
“√” after the type you choose.
SQU SELECT
SQU √
NB
DP
20
Figure 5.8
When the button CHK is pressed, the system performs the Self-BITE operation in each of the
modules and displays the Self-BITE results. The Self-BITE order is the power supply module, the
frequency synthesizer module, the digit module, the RX channel module, the TX channel module
and the antenna tuner module. After all the modules have been self-inspected, any button is pressed,
the system returns to the previous operating section. When the system performs the Self-BITE
operation, the antenna or the load must be connected in order to protect the veracity of the self-
inspection of the system.
When the button POWER is pressed, the MENU Power Select is jumped out. At this section,
the power grade shows alternately. The corresponding information can be displayed in the TX Power
Grade Displaying Section.
5.1.3 RX/TX Operation of the Fixed-Frequency Communication :
When the system is converted to be operated in the TX state, the bars of the in-coordinate
width are displayed to indicate the practical transmitting powers.
The RX Party can receive the operations such as the analog voice, the digital voice, the data,
the data lowest velocity transmission at any operating place that are transmitted from the TX Party.
When the RX Party receives the digital voice from the transmitting Party, the RX SINAD
(=Signal to Noise and Distortion Ratio), the TX velocity and the interlaced grate transmitted from
the transmitting Party are alternately displayed at the bottom line of the screen such as +23dB ,
600Z(Note : Z means not being interlaced).
When the RX Party receives the data from the transmitting Party, the RX SINAD (Signal to
Noise and Distortion Ratio), the TX velocity and the interlaced grade transmitted from the
transmitting Party are alternately displayed at the bottom line of the screen such as +23dB , 2400S or
2400L (Note : S means the short interlaced grade, L means the long interlaced grade).
When the CW messages have been received, the envelope pattern is displayed at the bottom of
the screen and there is the prompt sound. The system automatically stores the short messages that
are not read into the content of the short messages in the RX box that are not read according to the
time order. (Max 10 short messages can be stored in the RX box. When the capability is not big
enough, the short message that was stored first will be automatically deleted).
When the system stays at the analog voice operating position, the button PTT is pressed to
transmit the analog voice immediately. When the system stays at the digital voice operating position,
the button PTT is pressed to transmit the digital voice immediately. At the moment , the squelch
function should not be started, otherwise the analog voice operation cannot be received. When the

21
system stays at the data operating position, the button PTT is pressed to transmit the analog voice
immediately. If the data terminal is connected, the data (short interlaced or long interlaced)
communications can be transmitted.
Remark :
1、 Figure 5.9: The current channel has not been tuned or it is unsuccessful tuning. Re-tune the
current channel, or re-tune after frequency change.
2 、 Figure 5.10: Tx VSW of current channel is high. Check that whether there is shorted circuit
among antenna, RF cable from antenna tuner to transceiver, internal cables of the transmitter.

Figure 5.9 Un-tuned TX Protecting

Figure 5.10 TX SWR Protecting

5.2 Automatic Controlling Communication Mode :


5.2.1 Term Definitions of Automatic Controlling Communication :
Detect : It means that the compositing sequence of the selected operating channel quality
has been realized. After the Fixed-Frequency link has been established, the used operating channel is
the selected channel of the excellent communication quality. After the Frequency-Hopping link has
been established, the channels of the bad communication quality shall be deleted from the frequency
tables of both the RX Party Transceiver and TX Party Transceiver.
Single Call : It means that the single call operation uses the address of the single
transceiver to perform the call and establish the link with one transceiver.
Network Call : It is means that the network call operation uses the network addresses to
perform the network calls and establish the links with all the transceivers that have been registered

22
and edited into this network. When the network call operations are performed, the calling transceiver
will try to communicate the member transceivers that have been registered and edited into this
network. If some of the transceivers do not reply the calling transceiver, the calling transceiver can
also establish the links with other transceivers. When all the member transceivers that have been
registered and edited into this network set the network call member transceivers, the members, the
member numbers and the member orders must be the same.
Group Call : It means that the host calling transceiver can establish several temporary
networks according to the requirements. The host calling transceiver can establish the links with all
the transceivers that have been registered and edited in this network group. When the group call is
set, the host calling transceiver should have the addresses of the called transceivers.
Whole Call : It means that when the whole call operation is performed, the host calling
transceiver can establish the links with all the transceivers that have the same channels. This is the
single broadcasting call.
Automatic Control Communication : It means that the automatic control communication
has the function of selecting the excellent anti-jamming modes and establishing the reliable and
quick automatic link establishment (ALE) according to the operation types and the conditions of the
channel interferences. The called party transceivers can automatically track the operation types of
the calling party transceiver. The automatic control communication can detect preset frequency
collection and select the excellent frequency collection according to the detected results. In the
scanning state, the automatic control communication has the lowest limit grade of the
communication function. The calling frequency is separated from the operating frequency. After the
link has been established, the operation can be converted from the Frequency-Hopping
communication into the frequency- fixed communication. When the ARQ data stream is transmitted,
the automatic control communication has the function of establishing the self-adaptive frequencies
and the function of automatically dodging the interfering signals.
Calling Channels : It means that the automatic control communication calls the channels
that will be called to establish the links. They are the channel sub-collections 000 ~ 255. The
channels to be scanning are determined by the parameter Calling Channel and Scanning Channel
Numbers. After the Calling Channels have established the links, they convert to the operation channels
to perform the communications. If the link is the Fixed-Frequency link, the communication operation
is performed in this channel. If the link is the Frequency-Hopping link, the communication operation is
switched onto the operating channels of the Frequency-Hopping communication (the Frequency-
Hopping frequency table).
Operation Channel : It means that after the link of the automatic control communication
has been established, the Fixed-Frequency communication can be performed,. The operation
channels are the channel sub-collections 000~ 255.
Group Operating Parameter : It means that the main preset contents include the calling

23
channels, the operation channels, the low velocity CW channels, the Frequency-Hopping frequency
tables, the secret key groups, the dynamic scanning set and the relative parameters. The group is
names as the operating parameter group(or the parameter group). During the practical use, the
system uses the different operating parameters to meet the requirements of configuring the battles in
the different areas. They must not only ensure that the various communicating parameters of each of
the communication systems are not jammed or interfered one another in the different communication
but also ensure that the equipment or systems realize the inter-communications in the
communication networks. The automatic control communication function can provide 10 sets of the
numbers 0~ 9of the operating parameters of the different groups.
If the system stays in the operating mode of the automatic control communication while the
system was powered off last time, after the system has been powered on, the system stays still in the
scanning state of the automatic control communication. If the system stays in the other
communication operation mode, the button MODE should be pressed to jump out the Menu Com-
mode Set. The buttons ↑ ,↓ are used to select Automation , the button ENTR is pressed to
confirm the selection. A moment later, the system is converted into the scanning state of the
automatic control communication as shown in Figure5.11.

Figure5.11
●Displaying Areas 1, 2, 4, 5, 6, 10,11 : The contents are seen in the same descriptions of
the Fixed-Frequency operating mode.
●3 Parameter Group Number Displaying Area : The displayed digits mean the parameter
group numbers that the system is using presently. The group number range is 0 ~ 9. The group
numbers can be modified by means of pressing the buttons ↑,↓ .
●7 Scanning Channel Number Displaying Area : The displayed digits mean the scanning
channel number that the parameter groups of the system have selected at present.
●8 Function Displaying Area: AUTO means that the system stays in the operating mode of
the automatic control communication.
●9 Modulation Mode and Hop Speed Displaying Area : The modulation modes are seen in
the same descriptions of the Fixed-Frequency operating mode ; 5/S display the system will jump
5 channels per second.
●12 Calling Other Address Displaying Area : It can be set to single call address(100 ~

24
299), network call address(300 ~ 319), group call address(600 ~ 609) and whole call address
900.
●13 State Displaying Area : Scan means that the system stays in the scanning state.
5.2.2 Frequency Program and Parameter Set of Automatic Control Communication :
When the system stays in the scanning state of the automatic control communication, the
button MENU is pressed to display the operating interface Menu as shown in Figure 5.16. When the
button MENU is pressed, the system returns to the
previous operating section.

Figure 5.12
a) Channel Frequency Program of Automatic Control Communication :
The buttons ↑ , ↓ are pressed to move the cursor and select Frequency set. The button
ENTR is pressed to display the information as shown in Figure 5.13. This system has 256 presetting
channels(Channel numbers 000 ~ 255)for the automatic control communication. The channel
frequencies can be filled into with the outside filling gun and also by the manual set. The buttons
← , → are pressed to move the cursor. The buttons ↑ ,↓ or Digit can be pressed to modify the
values where the cursor stays. The button ENTR can be pressed to store the information into the
system. The button PTT is pressed to store and tune this frequency. When the button MENU is
pressed, the system returns to the previous operating section.

CH 224 Center
13.6789 USB

Figure 5.13
The Calling Channels, the operation channels, the low velocity CW channels and the
Frequency-Hopping frequency tables in each of the parameter groups are generated in the 256
channels. Among them, Table 1 of the Frequency-Hopping frequency tables : channels 064 ~
127 ; Table 2 : channels 128 ~ 191 ; Table 3 : channels 192 ~ 255. The channels
096, 160, 224 are the channels of the center frequencies. The Center Frequency will be displayed in
the center frequency channels (096, 160, 224).
Presetting the center frequency channels (096, 160 or 224). The button ENTR is pressed.
Whether generate a new frequency table, you can choose. The button ENTR is pressed to select Yes.
The button ENTR is pressed , a copy of the frequency tables is automatically generated and

25
tuned. The spaces of the frequency tables : 2kHz below 9.9999MHz, 10 ~ 14.9999MHz :
4kHz, 15 ~ 30MHz : 8kHz. When No is selected and the button ENTR is pressed, the system
returns to the previous above operating section. When the button PTT is pressed, only this frequency
is tuned.
b) Presetting the Universal Parameters : The operation is the same as described in Para Set
of the Fixed-Frequency communication by seeing Item 5.1.1. 。
c) Presetting the Automatic Communication Parameters :
The cursor is moved to Para Set. The button ENTR is pressed to display the information as
shown in Figure 5.14. When the button MENU is pressed, the system returns to the previous
operating section. The buttons ↑ , ↓ are pressed to move the cursor and select the followings
such as Frequency-Hopping Tables, Secret Key Group Set, Secret Key Values Set, Detect Holding
Channel Number, Link Protection, ARQ Frequency Quick Variation, Inner Group Scanning Channel
Number . The button ENTR is pressed to enter the operation of presetting various parameters. The
parameter descriptions of the automatic control communication are seen in Table 5.2.

Figure 5.14

Table 5.2 Automatic Control Communication Parameter Table


Default Cleared up
Parameter Name Setting Range Description
Value Value
Parameter Group
Number: 0 ~ Max 64 in each
Call CH 9; See Notes Group , 00 , 01
Channels : Min 2 in each Group,
000~ 255
Operation CH Number: 0 ~ See Notes Max 64 in each 00 , 01
9; Group ,
Channels : Min 2 in each Group,

26
000~ 255
Parameter Group
Number: 0 ~
1 Channel in each
Low SMS CH 9; See Notes 255
Group
Channels
: 000~ 255
Parameter Group
Number: 0 ~
Hop Freq-table 9; See Notes 1 copy in each Group Table 1
Tables : Table
1 ~ Table 4
Parameter Group
Number: 0 ~ They are used for the
9; link protection and
Key Group 00 00
Secret Key Frequency-Hopping
Group : 00 Synchronization
~ 99
ADD See Notes
The scanning Channel
Scan 3~ 9 8 Numbers in the Group 8
is set.
Least channel number
Hold Min CH Num 32, 16, 8, 4, 2 32 to be held after the 2
detection has been set.
Line Protect No, Yes No No
ARQ Auto Ch No, Yes No No

Table 4 is the Frequency-Hopping frequency collection that is generated by the center


frequency in the operation channels for establishing the links.
1) Setting the Calling Channels used in a parameter group :
When Call CH is selected, the button ENT is pressed to display the information as shown in
Figure5.15

27
Figure 5.15
In the Figure above, there are 5 calling channels in Parameter Group 0, and the third is
channel 096.
The buttons ↑,↓ or Digit can be used to input the parameter group numbers(0 ~ 9). The
button ← ,→ are used to move the cursor to Num, the button ↑ ,↓ are used to look through the
channels edited by different numbers, but you can’t change the number by pressing the buttons.
Move the cursor to Add and press the button ENTR, write the channel number into the system, and
press the button ENTR again, and then there is a new calling channel in the present group.
Meanwhile, Num and Sum will automatically add one. Move the cursor to the button Del, press the
button ENTR, and you delete the channel of the present number in the present group successfully.
Sum will decrease one automatically, but Num will possibly not be continuous. Press the button
MENU, and it will return to the interface of Parameter Set.
2) Setting the operation channel used in a parameter group:
Press the button OPER, and the setting process is the same as described in above mentioned.
3) Setting the lowest velocity transmission channels used in a parameter group :
Press the button SMS, and then the button ENTR to show the information as shown in Figure
5.16.

Figure 5.16
The buttons ← , → are pressed to move the cursor. Digit can be used to input the
parameter group numbers(0 ~ 9)and lowest velocity transmission channel number at present
parameter group.
Note : the lowest velocity transmission Channel is set in each group. This channel is
automatically added into the scanning channels in this group as a calling channel.
4) Setting the Frequency-Hopping frequency table used in a parameter group :
Press the button HOP and then the button ENTR, and there will be information as shown in
Figure 5.17.

28
Figure 5.17
The cursor stays in the parameter group number automatically. The button ← ,→ are used
to move the cursor. Pressing the button Digit is to change the parameter group number, the
frequency table and key group which are used in present parameter group. If Table 4 is selected, it
means that the Frequency-Hopping frequency table used in a parameter group is extended by the
center frequency of the operation channel for establishing the link communication.
5) Address Set : The address setting is only suitable for the automatic control
communication. The address parameters are seen in Table 5.3.
Table 5.3 : Address Parameter Table
Parameter Default Cleared up
Setting Range Descriptions
Name Value Values
Now 3 places are
Local ID Set 100 ~ 299 / used,they can be extended /
later.

Network Addresses :
Network Call
Net member set 300 ~ 319 ; 101 ~ 104 /
Member Number≤20
Members: 100 ~ 299

Group Addresses : 600


Group Member ~ 609 ; Group Call Member Number
101 ~ 104 /
Set Members: 100 ~ ≤20
299
ADDR is selected and the button ENTR is pressed to display the information as shown in
Figure 5.18. The button MENU s pressed to returns to the previous operating section. The buttons
↑,↓ are pressed to move the cursor to perform the selection. The button ENTR is pressed to enter the
operation of setting various parameters.

Figure 5.18
(1) Local ID Set
Local ID Set is selected and the button ENTR is pressed to enter the Local ID Set, which is
seen as shown in Figure 5.19. The button ← , → are used to move the cursor, and the button

29
Digit is to change the value of the place where the cursor stays. Local ID should be set within 100
~ 299.

Figure 5.19
(2) Setting the Net Member
The buttons ← ,→ are used to move the cursor, and the button Digit can be used to write
into the Net member numbers(300 ~ 319).The button ← ,→ are used to move the cursor to
Num, the button ↑ ,↓ are used to look through the member addresses edited by different numbers,
but you can’t change the number by pressing the buttons. If you want add one member into the
present net, move the cursor to Add and press the button ENTR, write the channel number into the
system, and press the button ENTR again, and then there is a new member in present net. Num and
Sum will automatically add one. Move the cursor to the button Del , press the button ENTR ,and
you delete the net member of present net. Sum will decrease one automatically, but Num will
possibly not be continuous.
(3) The method of setting Group Member Set is the same as the above described method.
6) Setting the secret key values used in the secret key group :
Key is selected, the button ENTR is pressed to display the information as shown in Figure
5.20.The cursor stays at the secret key group number automatically. The buttons ← → are pressed
to move the cursor. The buttons Digit are pressed to modify the values at the place of the cursor.

Figure 5.20
7) Setting the scanning channel number used by some parameter group :
SCAN is selected to display information as shown in Figure 5.21. Press the button ENTR ,

30
← , → to move the cursor to the place, Group scan num. The values can be changed by the
button Digit, and then press the button ENTR to save the values.

Figure 5.21
The scanning channel used by some parameter group must be several ones in front of this
group. With one lowest velocity channel, the total number is coincident with the number of the
group scanning channel. For instance, 0 group’s Group Scanning Channel number is 5 ; 0
group’s Calling Channel number is 000 001 002 003 004 005 006 007 ; 0 group’s Lowest
Velocity Channel number is 010 ; 0 group’s Scanning Channel must be 010 000 001 002 003.
8) Line Protect and setting ARQ Auto Ch
OTHER is selected and there will be information seen as shown in Figure 5.22. Press the
button ENTR ,and move the cursor to Line protect by the button ← ,→ , choose NO or YES by
the button ↑ ,↓ .And then move the cursor to ARQ by the button ← ,→ to choose NO or YES.
Press the button ENTR to write into the process above.

Figure 5.22

ARQ Auto Ch selects Yes. When the Fixed-Frequency ARQ establishes the link and both the
calling transceiver and the called transceivers cannot ensure the effective communication because
the link established channels have many errors and been jammed in these bad quality channels so
that the transmitting velocity falls down, both the calling transceiver and the called transceivers can
automatically be switched to the good quality channels to continue to perform the ARQ data
transmission.
Operation and Display of All the Buttons in the Scanning State of the Automatic Control
Communication :
The operating methods of the buttons MODE, OPRT, CHK, SQUELCH,POWER are the

31
same as the operating methods in the Fixed-Frequency RX state. The operation of the button OPRT
has another item of the ARQ selection. The interfaces of the operation of the Call Set are changed
correspondingly. At the moment, the buttons LATE ENT ,←,→ are not effective.
The button MENU is pressed to enter the operating interface MENU , seeing Item
The button DETECT is pressed to display the interface Detect.(Note : The operation of the
point to point communication can use the detecting function.)as shown in Figure 5.23. The number
following is the address which is to be detected.
The button MENU is pressed to returns to the previous operating section. The button ENTR is
pressed to enter the detecting address set.

Figure 5.23
If Detect ID Set is selected, after the button ENTR has been pressed, the buttons is going
back to→ automatically, Digit is pressed to change the address which is to be detected(100 ~
299). Press the button ENTR, the cursor goes back to DETECT ID ; Press the button ← ,→
to choose Fixed detect and then press the button ENTR, the operation channel which is set by
present parameter group is to be detected. When establishing the link, it will use the best quality
operation channel to establish the link. If Hop detect is chosen, press the button ENTR, the system
starts to detect the operation channels that have been set in the present parameter group. When the
later link communication is operated, the best operating channels are used to establish the links.
Hop detection is selected. After the button ENTR has been pressed, the system starts to detect all the
channels in the Frequency-Hopping tables set the present parameter group and to delete the channels
of the bad quality in the tables in both the calling transceiver and the called transceiver. (If the ARQ
link establishment is performed, when the parameter group set is not Table 4)
When the system is detecting the channels, it will actively detect the condition of changing the
scanning state into the detecting state of the other transceiver. If the detecting operation is required
to be terminated, when the system stays in the transferring RX state, the button Scan is pressed to
return to the scanning state. After the detecting operation has been finished, the system returns to the
scanning state so that the word Detect is changed into the word Scan.
The button RATE , is pressed to display 5/S,10/S,20/S in the operating section Hop Speed
Select alternately.
The button Scan is pressed to enter the operating state Call Set and display the information as
shown in Figure 5.24. The digit 103 in” →103” means the address of the transceiver to be called.

32
The button MENU is pressed to return to the previous operating section. The button ENTR is
pressed to ENT the selected set.

Figure 5.24
How to change the calling address? Move the cursor by pressing the button ← ,→ or Digit
to Call ID set , press the button ENTR ,and change the calling address (single call100 ~ 299,
network call 300~ 319, group call600~ 609, whole call900). At the same the number after →
changes correspondingly.
Only the single call mode can perform Fixed-Frequency Link Establish ARQ and Frequency-
Hopping Link Establish ARQ 10hops.
When calling, the interface as seen in Figure 5.25 below shows up. If the calling is to be
finished, the button SCAN is pressed to turn back to scanning state.

Figure 5.25
Single Call : The system calls the called transceiver in the scanning channel. If the system
receives the reply from the replied transceiver, the system will go to the operation channel to shake
hands with the replied transceiver. After the handshaking is successful, the link communication has
been established. If the system cannot receive the reply from the called transceiver or the
handshaking with the called transceiver is failed, the system will continue to call the called
transceiver in the next scanning channels. After the system has called all the scanning channels and
the link has not been established, it will return to the scanning state so that the word Call is changed
into the word Scan.
Network Call : The system calls all the members in the network in the scanning channels
first in order to inform them to go to the operation channels. Then the system shakes the hands with
all the members in the operation channels. If the system is successfully shaking the hand with one of
the called transceivers, the system has established the link with this called transceiver. If the system
is not shaking the hand with any one of the called transceivers, the system will continue to call the
called transceiver in the next scanning channels. After the system has called all the scanning

33
channels and the link has not been established, it will return to the scanning state so that the word
Call is changed into the word Scan.
Group Call : The system calls all the members in the group in the scanning channels first
in order to inform them to go to the operation channels. Then the system shakes the hands with all
the members in the operation channels. If the system is successfully shaking the hand with one of
the called transceivers, the system has established the link with this called transceiver. If the system
is not shaking the hand with any one of the called transceivers, the system will continue to call the
called transceiver in the next scanning channels. After the system has called all the scanning
channels and the link has not been established, it will return to the scanning state so that Call is
changed into Scan.
Whole Call : The system wholly broadcast and calls all the members in the scanning
channels in order to inform them to go to the operation channels. Then the system will establish the
links with all the members in the operation channels.

5.2.3 Operations and Display of all the Buttons in the Link Establishing State of the Automatic
Control Communication :
If it is the Fixed-Frequency link establishment, there is a prompt sound of the link
establishment as displayed in Figure 5.26. 004 means that the channels where the link establishment
operation is performed. The operation of the called transceiver automatically tracks the operation of
the calling transceiver. When the Other Addresses of the calling transceiver display the channels 100
~ 299, they mean the single calls(300 ~ 319 are the network calls; 600~ 609 are the group
calls ; 900is the whole call). The Other Addresses of the called transceiver only display the
address of the calling transceiver. The SINAD (=Signal to Noise and Distortion Ratio), the
frequency offset, the time delay and others such as +23dB, +4Hz, 00ms of the link establishment are
alternately displayed in the bottom line on the screen ,

Figure 5.26
When the system stays in the link establishing state, the operations of the buttons OPRT ,
Squelch , Power are the same operation as in the frequency- fixed communication mode. The

34
receiving transceiver can receive the analog voice, the digital voice, the data, the data lowest
velocity transmission at any operating positions. The receiving transceiver can also receive the
displaying information of these operations in the Fixed-Frequency communication. The system can
transmit the Fixed-Frequency data lowest velocity transmission or the Frequency-Hopping burst
data lowest velocity transmission at any operating positions. When the system stays at the position
of the analog voice operation, the button PTT is pressed to transmit the analog voice. When the
system stays at the position of the digital voice operation, the button PTT is pressed to transmit the
digital voice. When the system stays at the position of the data operation, the button PTT is pressed
to transmit the analog voice. After the data terminal has been well connected with the system, the
system can transmit the parameters (the short interlaced parameter or long interlaced parameter).
If the system has established the Frequency-Hopping link communication with another
transceiver , there is a prompt sound of the automatic link establishment (ALE) as displayed in
Figure 5.27. 10 hops means that the hopping velocity after the automatic link establishment (ALE).
The hopping velocity of the called transceiver will automatically track the calling transceiver. And
the operation of the called transceiver will automatically track the operation of the calling
transceiver. The Other Address of the called transceiver are the same as the above mentioned one.
The displaying information of the Other Address of the called transceiver are the same as the above
mentioned information. The parameter information is alternately displayed in the bottom line on the
screen.

Figure 5.27
When the button Detect is pressed and the system stays in the Fixed-Frequency link
establishing state, the system can quickly detect the operation channels set tin the present parameter
group. The word Link Establish in the displaying interfaces changed into Detect. After the detection
is finished, the links will be re-established in the detected excellent channels. At the same time, there
is a prompt sound. The system returns to the link establishing state. In the Frequency-Hopping link
establishing state, the channels of the bad SINAD shall be deleted from the mutual Frequency-
Hopping frequency tables of the present communication of the calling transceiver and the
transmitting transceiver. After the detection has been finished, the system returns to the link
establishing state. There is a prompt sound. Note : During the process of the detections, the
calling transceiver and the transmitting transceiver that are performing the detecting operations
cannot perform any operations.

35
When the button Mode is pressed, the Fixed-Frequency link can be switched into the
Frequency-Hopping link (the Frequency-Hopping frequency tables that are selected in the present
parameter group). The display is changed into the Frequency-Hopping link establishing section.
There is a prompt sound. Or the Frequency-Hopping link is changed into the Fixed-Frequency link.
(in the link establishing operating channels). The display is changed into the Fixed-Frequency link
establishing section. There is a prompt sound.
When the button Late Ent is pressed , the system transmits the guiding signal of the late
entering network according to the displayed other address. After the guidance has been finished, the
system returns to the link establishing section. There is a prompt sound. The transceivers of the
corresponding addresses that are scanned can be drawn into the link.
Now the buttons CHK , RATE, MENU, ↑, ↓, ←, → are not effective and there are the
alarming sounds.
When the button Scan is pressed to remove the link, the system returns to the scanning state.
If the link is the Fixed-Frequency ARQ link establishment or the Frequency-Hopping ARQ
link establishment, the mutual parties can perform the RX/TX converting operation orderly. When
the data terminal is connected into the system, the system can perform the ARQ data transmit. In the
receiving state, the RX.TX information such as +23dB (SINAD),1200t (transmitting rate while no
data)or 1200T(transmitting rate while having data), 1200r(receiving rate while no data)or
1200R(receiving rate while having data)are alternately displayed in the bottom line on the screen.
When it is necessary to remove the link, the button Scan is pressed. When the system performs the
effective time order, it gives out the order of removing the link.
5.2.4 Short Message Operation in the Link Establishing State of the Automatic Control
Communication :
When the button MSG is pressed in the RX operating state at any operation position in the
Fixed-Frequency Communication, the MENUSMS Function is jumped out to display the
information as shown in Figure 5.28. The buttons ↑ , ↓ are pressed to get the cursor so as to
select the operation of the Short Message Function Operation. When the button MENU is pressed,
the system returns to the previous operating section. The button ENTR is pressed to display this
function section.

Figure 5.28
Short Message : The short message is the whole name of the various data lowest velocity

36
transmission operations, including the single call, the network call, the group call and the whole call
of the automatic link establishment( ALE ) in the operating modes of the Fixed-Frequency data
lowest velocity transmission and the Frequency-Hopping burst data transmission, the Fixed-
Frequency data lowest velocity transmission at the low velocity and the data lowest velocity
transmission at the low velocity in the scanning operating state of the automatic controlling
communication.
a) Selecting read SMS :
The button MENU is pressed, the system returns to the previous operating section. When the
buttons ↑,↓ are pressed to move the cursor, the information sections Clear RX SMS, Clear TX SMS
are displayed in order to select Read RX SMS or Read TX SMS. After the button ENTR is pressed,
all the short messages are displayed in this Box. When the buttons ↑,↓ are pressed to move the
cursor in order to look for the wanted short message to be read . After the button ENTR has been
pressed to display the detailed contents of the short message, the button ENTR has to be pressed
again so that the information interface SMS Operation is displayed as shown in Figure 5.29. The
buttons ↑,↓ are pressed to move the cursor in order to select the Modify operation. And the button
MENU pressed so that the system returns to the previous operating section.

Figure 5.29
1) Send should be selected and the button ENTR is pressed so that the lowest velocity CW
can be transmitted in the present channel and this information can be stored into the TX box.
Note : the lowest velocity transmission is the broadcasting communication mode without the
SMS Set.
2) Save should be selected and the button ENTR is pressed in order to store this short
message into the TX box. (Max. 10 short messages can be stored in the TX box. When the capacity
of the box is not big enough, the short message that was stored in to the RX box first is
automatically deleted. ), and the system can return to the previous reading section.
3) Clear should be selected and the button ENTR is pressed in order to delete this short
message and the system can return to the previous reading section.
4) Edit should be selected and the button ENTR is pressed and this short message is displayed
in the editing interface so that this short message can be reedited and modified.
b) Selecting Edit SMS :
The button ENTR is pressed again so that the editing interface is displayed as shown in Figure

37
5.30. When the button ↓ is pressed, the inputting modes(Spelling, Character, Digits, Interpunction)
can be changed. The button ↑ is used to delete the character on the left side of the cursor in the
editing area. ← ,→ are used to move the cursor. Press the button MENU the system returns to
the previous displaying section from the present editing state as shown in Figure 5.29,and then send
or store the edited SMS. When you write characters into the system, press the corresponding
character on the keyboard, and then on the right of the screen there will be the character sequence
you want, see as shown in Figure5.30. Default the first character, and you can press this key for
several times. When the cursor moves to the character wanted, press the button ENTR the character
is written to the system. The button 0 is used to select the interpunction.

B_

Char: ABCab
c

Figure 5.30
When you want to write number into the system, press the button which has the number you
want directly, as the Figure 5.31 is shown.

4_

Num: 4

Figure 5.31
c) Selecting SMS Set
The button ENTR is pressed to display the information as shown in Figure 5.32. The button
MENU is pressed to return to the previous operating section. The cursor will flash when the button
ENTR is pressed.
The buttons←,→ can be used to move the cursor and select Times Set. The key board sets
the retransmitting times (1 ~ 3); the button ← ,→ can be used to move the cursor to select
the receiver’s address, and the receiver’s address is corresponding to the number on the key board
you can set yourself. Press the button ENTR to make sure that the addresses are written to the
system. Press the button MENU to return to SMS Set interface.
The system can transmit the short messages to the single call link establishing transceivers
according to their addresses. After the system has received their return receipts, it means that those
transceivers have successfully received the short messages. If the system has not received their
return receipts, the system will retransmit the short messages according to the retransmitting times.

38
The calling host transceiver that has established the network call, the group call and the link will
wholly broadcast the short messages without receiving the return receipts.

Remark :
1 、 Figure 5.33: The current channel has not been tuned or it is unsuccessful tuning. Re-tune the
current channel, or re-tune after frequency change. The used channel includes calling channel,
operation channel, L-SMS channel, center frequency channel in hop frequency table.
2 、 Figure 5.34: Tx VSW of current channel is high. Check that whether there is shorted circuit
among antenna, RF cable from antenna tuner to transceiver, internal cables of the transmitter.

Figure 5.33 Un-tuned TX Protecting

Figure 5.34 TX SWR Protecting

5.3 Remote Control Mode :


Press“MODE”, and such an interface is shown :

Select“Remoting” , press“ENTER” , and such an interface is given :

39
Here, the radio is waiting for the commands from remote controller.
The operation of remote controller’s fixed frequency and auto control communication is same
with that of that of radio.
6 Using Noticing Items :

 Before the system is used, all devices in the system should be connected correctly. The
conduct post of the transceiver and the positive pose” +” and the negative post” -”
should be inosculated with the corresponding positions of the battery group. The voltage
should be checked carefully(21V ~ 29V).
 Before the system is used, all the frequencies to be used must be tuned. After the
environment where the system is used has been changed, all the frequencies to be used
should be tuned again.
 Before the system is used, the date, the time and the parameters should be corrected.
 During the operation, if the operation is failed, the transceiver should be restarted again.

7 Common Malfunctions of the device and Maintenance:


7.1 Power Supply Inspection and Accessories Inspection:
When the failures have been found in the system, it should first determine where the failures
happen. It should be checked if the connections and the operations of the system are correct. After
the above item inspections have been finished, the power supply voltage of the system should be
inspected. After the system has been powered on, the button “Self-BITE” is pressed so that the
power supply voltage of the systems displayed on the screen. When the displaying value of the
power supply voltage of the systems less than 22V , it means that the voltage of the battery is
not enough, the battery should be recharged or replaced with the new battery. When the system is set
to the Fixed-Frequency position and a frequency is selected as well as the volume potentiometer is
turned to the Maximum position, some noises can be heard in the earphone set. When the button
PTT is pressed, the switching sounds of the relays in the system should be heard. If these
requirements cannot be met, the earphone set may have some failures. Now it should be checked if
the sockets are well connected. Or another set of the earphone set should be replaced to remove the
failures so that it means that the earphone set has the failures.
After the above inspections have been finished and the transceiver still has the problems, the

40
rear cover of the transceiver should be opened to check if the contacts of the plugs and the sockets of
each of the parts connected well and all the cables are connected well as well as if they have the
flexible phenomena. All the plugs and socket of the cables should be pressed tightly again then the
transceiver can be tried to be used.
7.2 Inspections and Replacement of the Parts in Each of the Units :
a) When the system performs the “Self-BITE” operation and displays “Channel TX
Failures” , the unit “DSP”, the unit “Front Panel” or the unit “Channel” may have the failures.
They should try to be inspected by replacing the units one by one.
b) When the system performs the “Self-BITE” operation and displays “Frequency Synthesizer
Failures” , the unit “Frequency Synthesizer” may have the failures. It should try to be inspected
by replacing this unit.
c) If the Frequency-Hopping operation, the self-adaptive automatic link establishing operation
and the data operation are not normal, the unit “DSP” , the unit “Frequency Synthesizer” and the
main control unit may have the failures.
d) If the displaying operation of the system is not normal and all the functional buttons are not
operated effectively, the main control unit and the displaying unit may have the failures.
7.3 Judgment and Repair of the Familiar Failure of the System :
The judgment and repair of the familiar failure of the system can be seen in Table
Table 7.1 Judgment and Repair Table of the Familiar Failure of the System
Failure Phenomena Failure Causes Repairing Measures
The causes of the fired and
The fuse of the system is fired broken fuse of the system are
and broken. inspected, repaired and
replaced.
The connecting lines and
The fuse on the battery is
wires inside the system are
fired and broken.
There is no display on the checked and repaired.
front panel and there is no The power supply unit has no The power supply unit is
noise in the earphone set. voltage output. inspected and repaired.
The 24V power supply cable
The 24V power supply cable
inside the system should be
inside the system is broken
inspected and the switch of the
and the switch of the
potentiometer with the
potentiometer with the
switcher is replaced with a
switcher is not ON.
new one.

41
The power supply circuits of
The normal +8V and RX+8V
the normal +8V and RX+8V
of the system have the
of the system should be
failures.
inspected.
The channel unit is inspected
The RF pass path way has the
The display on the front panel if the RF plug and the socket
failures.
is normal but there is no noise are ON.
in the earphone set or the The DSP unit or RF unit has The DSP unit and synthesizer
noise is very small. the failures. unit should be inspected.
The audio unit has the The audio unit should be
failures. inspected.
The volume potentiometer and
The connection of the volume
the connecting cables and the
potentiometer has the failures.
line should be inspected.
The power amplifier and the
The TX pass way has no
band- dividing filter should be
output power.
inspected.
The channel unit has no The channel unit should be
output. inspected.
The DSP unit should be
When the system transmits The DSP unit has no output.
inspected.
the signal, the RF power has
The audio unit should be
no output indication. The audio unit has no output.
inspected.
The main control unit has the The main control unit should
failures. be inspected.
The voltages C+8V and T+8V
The power supply has the
of the power supply unit
failures.
should be inspected. 。
The Self-BITE of the system The Self-BITE of the system According to the displayed
displays that a module has the displays that a module has the results, the corresponding
failures. failures. modules should be inspected.
The function of the automatic
The DSP unit should be
control communication is not The DSP unit has the failures.
inspected.
normal.
The control function is not The main control unit has the The main control unit should
normal. And the display is not failures. be inspected.

42
The front panel unit has the The front panel unit should be
normal.
failures. inspected.
7.4 Simple Failures Are Searched and Repaired Urgently :
When the system has the failures but it is required to be used urgently in the simple and crude
conditions and without special repairing instruments and tools, the prompt decision must be made
that the system should be repaired urgently according to the skilled experiences without considering
if the standard of the product is accorded with so as to make the needs of the system. The practice
can prove that the power from 10W to 20W, the inter-modulation from 15dB to 30 dB of the
transmitter, the sensitivity from 1μV to 10μV and the distortion from 5% to 15% of the receiver shall
almost not affect the communication of the system obviously and some technical specifications shall
not affect the communication very little. So, in the urgent situation , the system has adopted the
connecting and inserting structures of the units so that the system has the interchangeable
characteristic and the unit boards or the unit boxes of the backup systems or transceivers can be
removed and inserted in the system which has the failures. And the units, the units and the parts and
systems that have the failures of several sets of the systems can be collected onto one set of the
backup system or transceiver. In the conditions of the allowed time and the complete system as well
as the more backup transceivers, the normalized maintenance and repair are performed or they are
sent to the relay grade station to be repaired.
7.4.1 Listening Method :
After the antenna has been connected with the main set of the normal product, some big
noises can be heard in the earphone set. If there is no noise, generally the audio unit and the DSP
unit have the failures. Although the noise is very small but there is some , generally the channel
unit and the frequency synthesizer unit have the failures. If the noise is basically normal but the
signal cannot be received, generally the channel unit and the band-dividing filter unit as well as the
antenna unit have the failures.
7.4.2 Seeing Method:
The place CW is observed if the level has the indication, the indication is small and big, the
total current output of the regulated power supply is small and big while the system is tuned. If the
receiving is basically normal, the total current output is very small while transmitting the signal, the
indication of the level is very small or no indication. When the pencil or screwdriver is used to touch
the antenna, there is no spark on the antenna(at the low frequency end) , the power amplifier unit,
the band-dividing filter unit or the antenna tuner unit have the failures.
7.4.3 Interference Inputting Method :
The human body is a very good interference source so that it can be used as the interference
source. When the metal screwdriver or the sharp forceps can be used to touch the relevant parts of
the system, the sound “Kala” in the earphone set can be heard to judge the failure places.

43
When the earphone set is connected, the power supply switch is turned on, the lower cover is
removed and the volume potentiometer is turned to the max position, the intermediate smooth
interference noise can be heard in the normal system at this time. When the metal screwdriver or the
acutilingual forceps can be used to touch the antenna seat, the output terminal of the filter unit, the
output terminal of the channel unit and the output terminal of the DSP unit in turn, some interference
sounds “Kala” can be heard in the earphone set. According to having or not having the interference
sounds “Kala”, it can be judged if the antenna tuner unit, the band-dividing filter unit, the channel
unit or the DSP unit has the failures.
7.5 Storage and Maintenance in Storehouse :
The storage and maintenance in the storehouse is also the important task of the life quality
management of the system. The storehouse where the system is stored should have the good
environment. The storing and repair in personnel should be familiar with the technical specifications
of the system and the inspecting methods. The storing and repair in personnel should understand the
changing conditions of the quantity and the quality of the systems during the storing periods. The
storage and maintenance of the storing period in the storehouse shall be divided into 4 kinds : the
check and accept of storing the system into the storehouse ; the storage and maintenance for a
long time ; the temporary storage and maintenance ; the inspection and maintenance before
the battle starts ;
7.5.1 Check and Accept of Storing the System into the Storehouse :
The system quality of leaving the factory and the quality of the systems after the
transportation should be the important tasks of delivering and accepting the system between the
manufacturing factory and the storehouse managing personnel. The storehouse managing personnel
shall accept the system and store them into the store house according to the contract of ordering and
storing the systems or the order from the high authority. The general check and accept working
procedure is described as the followings :
a) The quality inspection of the packing appearance :
The quantity of the systems is counted according to the quantity and the name of the
<<Good List of Delivering and Accepting the Goods>> ;
The Trade Mark quality of storing and transporting of the Goods on the packing cases should
be inspected;
The quality of the packing wooden cases of the system should be checked. The packing
wooden cases of the system are divided into two parts : the outside transporting wooden cases
and the inner packing cases that are accorded with the packing standards of the military
equipments ;
The lead realization of the wooden packing cases should be inspected if they are good and the
wooden cases are stable and firm.
b) Complete Set Inspection While Opening the Packing Case :

44
The case-opening inspection shall be performed according to the check and accept quantity of
the systems to be stored in the storehouse and the regulations of the storehouse.(5% of the total
quantity of the systems are selected and are inspected generally while opening the packing cases).
The items and contents listed in the packing lists should be checked with the practical goods. The
names, quantities, specifications of the main transceivers, the accessories, the backup parts and the
technical documents in the packing cases should be accorded with the packing lists. The main
transceivers, the accessories and the backup parts of each set of the systems are packed in their own
packing boxes (bags). The complete transceiver systems are packed in the wooden cases firmly and
accorded with the shockproof requirements. The surface qualities of the main transceiver and the
backup parts should have no obvious scars and moldy rusted and cankerous phenomenon as well as
no shorted parts.
c) Configuration Inspection :
When the system is normally operated, the usability, the interchangeable ability, of the main
transceiver, the attached accessories and the peripheral equipments that are matched and connected
with the main transceiver should be inspected. The antennas, the earphone set, the handset, the
transferring cables and the battery group and other attached accessories should be separately
connected according to the technical operation manuals
(When it is necessary, the crypto and the telephone set can be remotely connected.). The connecting
and inserting conditions of the antennas and other accessories should be inspected if they are well
matched , if the contacts are reliable and firm, if the fibulas are locked firmly, if the same types
of the accessories can be interchanged, if the potentiometer on the front panel of the main
transceiver can be smoothly circumrotated, if the hopping steps of all the switches are clear, if the
contacts are reliably touched and if there are the deadlocked phenomena as well as if the displaying
window and fastening parts are good. After the supporting connections of the complete transceiver
have been inspected, the system should be powered on and its operating abilities can be inspected as
well as the short distance communication can be performed.
d) Measurement of Electric Performances and Specifications:
The electric performances and item specifications, the measuring methods and the instrument
Applications can be performed according to the 《 Product Regulations of XD-D12B 24V 》 .
When the storehouse has no complete conditions, the main technical specifications can be measured.
Or all the functions of the inspected system can be inspected during the short distance
communication experiment.
e) Qualified Goods are sent into Storehouse after the Check and Accept are Completed :
After this batch of the systems is checked according to the quality standards of sending the
systems into the storehouse, the managing personnel of the storehouse should accept and sent the
goods into the storehouse. The opened and checked systems should be counted and cleaned
according to the items, the specification, the quantity listed in the packing lists and are repacked into

45
the wooden cases according to the packing requirements. Finally the packed wooden cases are lead-
sealed and sent into the storehouse.
f) Treatment of the Unqualified Systems :
When the systems are found to have the bid quality problems during the storehouse check and
accept and are refused to accept the systems, the storehouse managing personnel should quickly
inform the manufacturing factory to send the responsible representatives to the storehouse in order
to perform the quality cognizance. After the factory have repaired the systems and solved the big
quality problems and the managing personnel of the storehouse should check the systems once
again. The qualified systems can be stored into the storehouse. When a few of the systems are found
to have the quality problems, the managing personnel in the storehouse can repair them. The
managing personnel in the storehouse can inform the factory to send the technicians to come to
storehouse to repair the systems in the storehouse and send the systems that cannot be repaired in the
storehouse back to the factory. The factory will subjoin the shorted parts of the systems. The
storehouse will assist the factory to negotiate with the transporting department to solve the quality
problems caused during the transportation of the equipments.
7.5.2 Storage and Maintenance for a Long Time:
The managing personnel in the storehouse are responsible for storing and maintaining the
systems for a long time as well as performing the good quality tracking and maintaining work in
order to ensure the quality of the systems during the storing period so that the following items of the
work should be done:
a) Storing Work of the Systems:
The storehouse where the systems are stored should have the good environment conditions
such as the aeration, fireproofing, damp-proof, antisepsis, waterproofing measures. The packing
wooden cases should be placed on the pillow woods that are 30cm higher than the ground surface.
The packing wooden cases should be 1m far away from the walls so as to keep the ventilation in the
storehouse.
b) Quality Tracking and Maintaining Work in Storing Period:
The certain quantity of the systems that are stored for a long time can be taken out according
to the fixed date of the year so as to open the packing cases to inspect the systems. It is better to take
out the sampling quantity by prorating the systems into the batches of the year.
c) Quality Statistics and Feedback of the Systems in the Storing Period :
The managing personnel in the storehouse should perform the work of collecting the quality
data and the statistic work of the systems stored in the storehouse from the time when the systems
are sent into the storehouse to the time when they are delivered to the users from the storehouse so
that the quality files of the systems can be established for the higher authority departments and the
factory to evaluate and query the quality of the systems.
7.5.3 Temporary Management and Maintenance:

46
Because the systems are temporarily stored in the storehouse for a short time and will be sent
to the users very soon, the qualities of the systems will not be changed greatly in the normal
condition. If the systems are not be well stored in the bad environment conditions of the storehouse,
the quality problems will happen so that the special attention of the work of the temporary storing
systems should be paid. The storing requirements of the temporary storing systems are the same as
the long storing conditions. The quantity of the taken out systems to be inspected should be
determined according to the task property and the orders of the higher authority. Generally speaking,
when the systems are delivered to the stress army to shoulder the stress tasks, they should be wholly
inspected and maintained. When the systems are delivered to the common duty and training army
forces, the sampling inspection of the systems should be performed. The functional specifications,
the accessories, the backup parts of the systems should be strictly inspected so that the army forces
can use the systems of the best quality and the complete configuration. When the systems are
delivered to the army forces, the managing personnel in the storehouse shall make the recording
notes. The simple failures of the systems should be well repaired before delivering the systems to the
users. If the managing personnel in the storehouse cannot repair the systems or find that the
accessories and spare parts are shorted or have the problems, they should inform the factory to send
the technicians to repair the systems or subjoin the shorted and damaged parts or components. The
systems to be delivered to the users must be packed firmly and reliably so that the systems can make
the requirements for the long distance transportation.
7.5.4 Inspection and Maintenance before the Battle Starts :
The inspection and maintenance before the battle start is a urgent and important maintaining
task. When the storehouse accepts the order from the higher authority department, if the systems are
found to have the quality problems, the stored systems shall be inspected, repaired and sent to the
army forces quickly. 100% functional performances, the technical specifications, the complete
configuration, the matching property, the interchangeability of the systems should be urgently
inspected. The capability of the matched battery groups should be recharged and resumed so that
each set of the systems can have a good operating state and the reliable safe quality of the systems.
The maintaining descriptions should be noticed in the record manuals.
If the accessories and spare parts of the systems are shorted and the problems cannot be solved
immediately, it can be done that the accessories and spare parts can be collected from many sets of
the systems and combined into a set of the system to be used.
After the army forces have accepted the systems, the operators should open the system cases
to check the integrality of the main sets, the accessories and the spare parts of the systems. When the
voltages of the battery groups are not full enough, they should be charged immediately. The
antennas and the earphone sets should be connected with the main sets according to the operation
manuals so as to check and inspect if all the functions of the systems can be operated normally in the
short distance communication. If the quality problems have been found, they should be solved

47
immediately.

8 Requirement and Method of Packing, Transporting and Storing the


Product for a Short Time :
8.1 Packing and Transporting
a) The operations should be done strictly according to the storing and transporting marks on
the packing cases ;
b) In the loading and unloading operation, the special attention should be paid that the heavy
cases and big cases are placed at the lower layer. The center of the gravity cannot exceed 2m. The
stack of the cases should be piled up orderly and reliably. The loading weight cannot exceed the
rated weight of the truck ;
c) The cases are loaded onto the trucks according to the relevant regulations of the height and
the width. The packing parts shall be placed averagely. It is not allowed that the cases are leaned to
one side.
d) When the trucks are used to transport the good cases, the running speed shall be controlled
according to the road conditions so that the equipments cannot be damaged.
e) It is not allowed that the flammable, fiery and cankerous objects are loaded and transported
on the same trucks.
f) When the equipments are transported on the trucks, the waterproof, the dustproof, the solar
shining and shocking measures such as the tarpaulin of covering the equipments on the trucks
should be adopted.
g) When the equipments are transported on the train, the equipments should be loaded in the
vans or carriages.
h) The communication vehicles, the tow trucks and other vehicles on which the
communication equipments have been installed can be transported on the trains.
i) During the transportation and loading or unloading operations, if the equipments are found
to have been damaged, it is urgent to inform the relevant departments to handle them.
8.2 Storing Regulations:
a) The different models, types of the equipments should be separately stored, piled up orderly
and not conversely.
b) The equipments should be placed and stored separately with the causticity, flammability
and explosive goods.
c) The equipments should be placed on the instrument shelves.
d) The packed cases should be placed on the crossties that are 30cm higher than the ground
surface , the stow height cannot exceed 4.5m , the stows should be 1m far away from the
walls and the ventilation in the storehouse should be kept.
e) The simple packed antennas and others are not allowed to be stored in the open air.

48
8.3 Requirements of the Storehouse:
a) The storehouse should accorded with the following atmospheric conditions:
Temperature : 5℃~ 30℃ ;
Relative humidity : 50 % 70 %
b) The storehouse should have the horizontal cement ground surfaces in the storehouse. The
heights of the horizontal cement ground surfaces should be 40cm higher than the ground surface.
c) The storehouse should prevent various noxious gases and causticity chemical goods from
damaging the equipments.
d) The storehouse should have the good ventilation and dustproof measures as well as to keep
the clearness.
e) There should not be the strong mechanical vibrations and the electric field as well as the
strong magnetic field around the storehouse.

9 Operation Instruction for Data Transmission Software


9.1 Installation of Software:
Run the file “SlipData Setup.exe”, then click “NEXT” or “OK” button step by step, so that the
data transmission software will be installed into your computer.
9.2 System Connection:
After the transceiver has been connected with the power supply and the automatic antenna tuner
well, the transceiver should be connected with computer with the data transmission cable. One end
of the data cable is connected with the serial port of the computer. The other end of the data cable is
connected with the data access port of the transceiver. Set the transceiver to the“Data” mode.
9.3 Operation of Software:
After the software has been installed into the computer and the software has been run, the
software’s interface is displayed as the following (Figure 9.1).

49
Figure 9.1
a) Setting with Communication Protocol
Click the“Setting” button, the dialog box will be shown as following(Figure 9.2).

Figure 9.2
Click the “Modify” button , then input your own node address and node name into “User
ID”and ”User Name” .You must input 5 numbers for “User ID”, it means the user address of the
local computer. After these information have been input finish, click “OK” button.
Select the COM which the computer is communicated with the transceiver in the “Port”
frame.

50
Select the kind of communication protocol in the “Flow Control” frame.
It is used to select the information flow control when the computer is communicated with the
transceiver. After the selection has been finished, the information flow control that is the same as
that in the computer must be preset in the transceiver. When“Slip”is selected and the encrypted data
to be transmitted is preset, the “slip” and the encrypted data to be transmitted must be preset in the
transceiver.
All of the selection has been finished, click “OK” button to save the preset information. If
click“Cancel” button , all the preset information are given up.

(2) Receiving of Files and Short Messages (SMS):


The shown on the upper part is the saving path and sending path of the transmitted and
received file. The defaulted path is “C:\TEMP\” . If the path is necessary to be modified, click
the“Save path” button, then the dialog box will be shown in the following figure(Figure 8.3).

Figure 9.3

After the path has been modified, click the “OK” button, the file or the short message or the
picture to be saved through the path.
The left middle frame is the receive display (Figure 8.4). If the short message is received, it
will be displayed in the frame.

51
Figure 9.4

If the received content is the file(not sms), after the file has been received, the file will be
saved on the path“C:\TEMP\” or on the path that you have preset. When the received file is double
clicked, it can be opened with the corresponding software. If you want to clear the contents in the
receiving frame, click the“Clear” button under the receiving frame. If you want to save the contents
in the receiving frame, click the“Save” button. The contents in the receiving frame will be saved in
the format of the “TXT”file.
(3) Receiving Picture:
If the received content is picture, it will be displayed in the frame. With the increasing of the
received data, the received and displayed picture will become clearer and clearer (Figure 9.5). After
the picture received has completed, it will be automatically saved.

Figure 9.5

52
(4) Presetting of Communication Address and Node:

Figure 9.6
The number “99999” is the broadcast mode that has been defaulted in the system. It is the
communication mode of one point –to-multi-points. When one point transmits the information, if the
receiving frequencies of the other transceivers are the same ones, they all can receive the transmitted
information at the same time. If the addresses and names of the other transceivers are added into,
click the“Append” button as shown in the following (Figure 9.7).

Figure 9.7
For example ,in the figure 9.7, the number“22222” expresses the user node address. The 5
numbers can be input at this place in order to show the user node address. “station2”expresses the
name of the user node. The user name can be input at this place, it makes up of letters or numbers.
After the above two items have been input, click the“OK”button. The present user name and
node address can be added into.
(5) Transmitting Short Message, File and Picture:
Such as Figure 9.1, the right upper part is used to transmitting the file and the picture. Click
the “File send” button, then select the file which will be transmitted in the file selection box( Figure
9.8).

Figure 9.8
Selected the file and click the“OPEN”button to send it.

53
Click the “Picture send” button, the dialog box will be displayed such as the following figure.
(Figure 9.9)

Figure 9.9
Select the disk and the path and the file name on the left part, the picture will be displayed on
the source picture frame. Click the “Send Source” button to send the source picture.
If the bytes of the picture file are too large, it is necessary to compress the picture. The
operating method is: press the left button of the mouse and drag bar “Quality” to change the quality
of the compressed picture. Input the size scale of the picture after the “Scale” position. Click
the“Convert” button to finish(Figure 9.10).

54
Figure 9.10
The compressed picture has been shown in the “Destination Picture” frame on the right side.
If the bytes of the picture file become smaller, the required time for sending will become shorter.
Click the“Send Dest” button, and the compress picture will be sent.
If you want to sent one part of the picture, Click the“Clipping” button first .Draw a frame
round using the mouse on the picture which part you need. And then click the“OK” button to select.
Finally, click the “Send Dest” button to sent it (Figure 9.11).

Figure 9.11

Click the “Cancel” button to close the dialog box in order to cancel this operation (Figure 9.10
,Figure 9.11).
The short message sending form is as the following (Figure 9.12). The Figure 9.12 is incepted
from the right part of Figure 1. The displaying frame is used to edit the short message. And the user
can edit the short message here. After the edit operation has been finished, click the “Send”button to
send it out.

55
Figure 9.12
The other operation of sending short message is:
Import a“TXT”file into the editting frame, and click the “send” button.
Click the“Clear”button to clear the contents in the editing frame.
Click the “Cancel” button to abort the process of sending short message.
“Send[0%] ”and“Recv[0%]”are the process for sending and receiving the data that indicate
the sending and receiving process.
“Encryption”is a selected item of the file and the short message. It is used to encrypt the file and the
short message. Select the “Disable”, the file will be sent without encrypted. Contrarily, select the
“Enable”, the file will be sent in encrypted mode.

10 Noticing Items
10.1 Before the transceiver is operated, it should be checked if the antenna, the microphone and
other external equipment have been well connected. After the frequencies to be used must have been
tuned, the frequencies can be used. After the using environment has been changed, the frequencies
and channels should be retuned well so that the security of tuning the transceiver can be ensured.
When the transceiver is tuned, the long key should not be pressed. When the keys are pressed, any
switch should not be turned on or off.
10.2 When the transceiver is operated, if the failure condition of the operation happens the
transceiver should be re-started again. If it has been found that the transceiver has the abnormal
phenomena during the operation, the transceiver should be repaired in time.
10.3 When the transceiver stays at the place “TEST”, the consumer should not use the transceiver.
During the operation, the consumer should not press the key “TEST”, otherwise, the consumer

56
cannot normally use the transceiver.
10.4 After the transceiver has finished the operation of the transceiver, the volume switch should be
turned to the place “OFF”.
10.5 When the transceiver stays in the receiving state, it has some quantity of the combining
interference points. So during the operation, these quantity of the combining interference points
should be avoided.
10.6 When the battery is charged, it is found that the temperature of the battery box is quickly
increased, the charging should be stopped at once. It should be checked if the battery box has been
failing and the failing batteries should be taken off. When the normal temperature has been resumed,
the charging can be continued. If it is necessary to open the power supply, the special repairing
operator should be invited to do it.
10.7 The battery group should be checked and test in the regulated time. And the damaged batteries
should be taken off in time.

11 Y130A Power Supply

11.1 Brief Introduction

Model Y130A24V Power Supply, a kind of DC high frequency switch power supply, is designed for
the radio set especially. It is a high technology product which integrates the high frequency pulse
width modulation technology, soft switch technology, SCM control and battery management
technology. The power supply reaches to the advanced level in electric, calorific, machine and other
fields, because we adopt the advanced new type electric components and advanced craftwork
technology, also the circuit is elaborate designed and optimized. The power supply has the features
of small volume, light weight, high efficiency, low temperature rise, high reliability, superior electric
performance, beautiful appearance, easy maintenance and so on.

11.2 Operation Condition

Operation temperature: -25℃ ~ +70℃

Relative humidity: ≤95 % ±3 % (40℃±2℃)

11.3 Main Technical Specifications

11.3.1 AC input

57
AC input parameters, are seen in Table 11.1.

Table 11.1 AC input parameter

Single phase input


220V±20%
voltage

Frequency 45Hz ~ 65Hz

Efficiency ≥82 %

11.3.2 DC output
DC output parameters, are seen in Table 11.2.

Table 11.2 DC output parameter

24V( adjustable 24V ~


Power supply output voltage
27V)

Power supply output current 30A

11.3.3 Power system adjustment rate: ≤±0.1V


11.3.4 Load adjustment rate: ≤±0.5V
11.3.5 Peak value noise voltage: ≤50mV
11.3.6 Security performance
11.3.6.1 Insulation resistance

When the test voltage is DC 500V, the insulation resistance value which AC input and DC
output of the power supply to AC input and DC output of ground is not less than 10MΩ.

11.3.6.2 Insulation intensity

Power supply AC input to Ground, AC input to DC output can bear 2200V DC voltage
(Leakage current is less than 10mA), time is 1min, and no break through and no arcing
phenomena.

11.3.7 Reliability

MTBF is not less than 20 000h

11.3.8 Maintenance performance

58
MTTR is not larger than 30 minutes.

11.4 Dimension, Weight, and Cooling Mode

11.4.1 Dimension: 200mm×110mm×310mm(Width × Height ×Depth)


11.4.2 Weight: Not larger than 10kgs
11.4.3 Cooling mode: air blower for cooling.

11.5 Work Principles

11.5.1 Basic work principles

This power supply is consisted of AC input, high frequency transformation, pulse width modulation
control, high frequency filter, DC output, SCM monitor, front panel circuit and assistant power
supply. The basic work principle is shown in Figure 11.1.

Figure 11.1 Principle Block Diagram

11.5.2 AC input circuit

AC input circuit is consisted of EMI filter, high voltage rectifier, surge suppression, high voltage
filter, and other parts. Its function is changing AC 220V voltage to 310V DC voltage, supply the

59
noise separation between the power system and the power supply, and limit the surge charging
current when started the machine instantly.

11.5.3 High frequency transformation circuit

It is consisted of high voltage and high frequency switch pipe, high frequency transformer and other
components. Its function is to make the high voltage DC change to the wide AC pulse in the control
of pulse width modulation drive signal. Because of using the advanced zero voltage switch and zero
current switch technology (ZVS, ZCS), the voltage of the switch pipe, current stress and switch loss
are decreased effectively. The self-power consumption of the power supply is low, so the reliability
and efficiency of the complete set are improved. Also it can decrease the electromagnetism
interference.

11.5.4 Pulse width modulation control circuit

It is consisted of the pulse width modulation circuit, drive circuit, over current protection circuit,
limited current circuit, over voltage protection circuit, temperature inspection, protection circuit,
sampling circuit and other parts. Its function is to provide the pulse width modulation drive signal
which the power supply needed, provide the protection for the input, output, temperature and other
abnormal phenomena, in order to realize the safe operation of the power supply and load, also
realize the electric performance of power supply regulated voltage, limited current and other
performance.

11.5.5 DC output current

It is consisted of the high frequency rectifying filter, EMI filter and other circuit. Its function is to
make the high frequency AC pulse by the pulse width modulation changed to the high quality DC
voltage output with low noise, low electromagnetism interference.

11.5.6 Single Chip Microcomputer (SCM) monitoring circuit

It is consisted of SCM, SCM external circuit, simulation interface circuit, digital interface circuit,
display keyboard interface circuit and other parts. Its function is to finish the information transfer
between the pulse width modulation control circuit and the front panel, and the relative information
process. It inspects the analog quantity and switch quantity sent by the pulse width modulation
control circuit, and send the relative quantity to the front panel for display, other side it also receives
the signal sent by the front panel keyboard, to manage the pulse width modulation circuit, and

60
control the operation of output voltage and the power supply.

11.5.7 Front panel circuit

It is consisted of LED display circuit and keyboard, its function is to achieve the display of the
relative quantity, and receive the manpower key in information.

11.5.8 Assistant power supply

The assistant power supply is to provide the operation power supply for the high frequency
transformation circuit, pulse modulation control circuit, monitor circuit and display circuit.

11.6 The Sketch Map and Introduction for the Front and Back Panel

11.6.1 The sketch map of the front panel

The sketch map of the front panel is in seen in Figure 11.2.

Figure 11.2 The sketch map of the front panel

61
① : Handle-pull ②: Air inlet ③ : Current display
④ : Voltage or temperature display ⑤ : Rubber cushion
⑥: Red light when remove the battery ⑦ : Ship form switch
⑧ : Alarm red light for over voltage
⑨: Alarm red light for over current
⑩ : Key-press ⑾ : Alarm red light for over temperature

11.6.2 The sketch map of the back panel

The sketch map of the back panel is seen in Figure 11.3.

Figure 11.3 The sketch map of the back panel

① : Power supply output socket ② : Air outlet


③ : Charging output socket ④ : Ground pole ⑤ : AC input socket

11.6.3 Definition of the socket

11.6.3.1 AC 220V input interface socket: TJ20-03ZJH-1, pin definition is seen in Table11.3.

Table 11.3 AC 220V input interface

62
Sour
Pin Name To Electric performance
ce
- Phase line Phase line
+ Zero line Neutral line
T Casing Ground protection

11.6.3.2 Power supply output interface socket: YLDB20N1204aJA-1, pin definition is in Table 11.4.

Table 11.4 Power supply output interface

Sourc Electric
Pin Name To
e performance
1, 4 Output + Power amplifier + 24V/30A
2, 3 Output - Power amplifier - 24V/30A

11.6.3.3 Battery interface socket: YLDH20N1204aK-1, pin definition is seen in Table 11.5.

Table 11.5 Charging output interface

Sourc Electric
Pin Name To
e performance
1, 4 Output + Battery positive 20A

pole
2, 3 Output - Battery negative 20A

pole

11.7 Display and Setting

Cautions

If it is failed to maintain in accordance with regulation or there is problem which has not been
solved, the equipment can not work in “sick state”, except it is confirmed that there would not be
personal injury or equipment damage.

63
11.7.1 Button setting

There is 1 button on the front panel for output voltage setting and power supply information
query. It displays voltage of the power supply, current, internal temperature of power supply in
turn by button pressing. Press the button for about 5 seconds (green-lamp OUT is flashed once) to
enter to setting of output voltage state. Adjust the output voltage by button pressing until regulated
voltage value and holding on for about 5 seconds (OUT green-lamp is flashed once) to confirm
the voltage setting is valid. Meanwhile, exit from the state of output voltage setting. It is shown as
diagram 4. Remark: It is forbidden to press button for long time!

Diagram 4 Diagrammatic sketch of button operation

11.7.2 Digitron display and LED display

Switch on the AC power supply, set the switch on the panel at “open” position, and the green

64
indicator for power supply on the front panel is on. The LED displays voltage and current of the
power supply. The definition of Digitron and the state of corresponding indicator are shown as
table 11.6.

Table 11.6 Detailed information of PS display

Indicator Explanation
Red indicator of battery is on Switch off the battery state
Over-voltage red-indicator is The PS is in the state of over-
voltage while the equipment is shut
on
down
Over-current red-indicator is on The PS is in the state of over-
current while the equipment is shut
down
Over-heat red-indicator is on The PS is in the state of over-heat

while the equipment is shut down

11.8 Instruction about Installation, Operation and Disassemble

Attention

The practical operation environment of power supply should meet the requirements of
objective environment conditions from sub-system. If not available, necessary
measurements should be done to guarantee the operator safety and extend the operation
life-span of the equipment.

11.8.1 Installation, Connection

Input/output plugs connection of the power supply, the procedure is shown as followings:

The 1st step:Set the panel switch of the power supply in “off” position, inspect external AC
switch and confirm that connect the AC plug in the switch-off state.
The 2nd step:Connect the plugs of charger.
The 3rd step:Connect the plugs of power supply.

Otherwise, there is arc arcing discharging among insertion components during plugs

65
connection, so that the insertion components are easy to be damaged.

11.8.2 Operation

Before powered on, inspect the AC input, DC output of the power supply to guarantee stable
connection. Set the panel switch of power supply in “on” position, and the panel displayer shows
the voltage and current of the power supply. Internal temperature of power supply could be
displayed by panel button selection. The power supply mainly supplies power to load with
24V/30A output.

Caution!

Make sure that the power supply is well grounded in operation.

11.8.3 Disassembly

When there is fault of power supply or some other reasons, so that it is needed to be replaced,
the process is shown as followings:

a) Set the panel switch of power supply in “off” state ;

b) Switch off the external power switch of the power supply;

c) Take out the input plugs and output plugs

Caution!

It is forbidden that the power supply is on with power when transceiver is in repairing.

11.9 Solution for Common Faults

11.9.1 Over-voltage alarm while the equipment is shut down

When output voltage of power supply exceeds 29V±0.5V, the power supply would be shut
down for protection. At the moment, disassemble the power supply and maintain the transceiver.

11.9.2 Over-temperature alarm while the equipment is shut down

When it is high environmental temperature or radiating path is blocked, environmental

66
improvement measurements should be carried out. If it is still abnormal, disassemble the power
supply and maintain the transceiver.

11.9.3 Over-current alarm while the equipment is shut down

If it is load short-circuit or heavy load, inspect the load first. If the load is normal,
disassemble the power supply and maintain the transceiver.

Attention

The above solution is especially suitable for professional technician. About the
unprofessional person, please switch off the switch of fault power module immediately once
there is power fault. After it is switched off, replace it by spare power module and inform
nearest office or market departments of our company. Unprofessional people are not
allowed to disassemble power module for maintenance in avoid of danger.

11.10 Maintenance Method

This power should be operated in the clean and ventilation environment.

All power parameters have been adjusted well already before factory delivery. Generally
speaking, no need to re-adjust. Daily records about power system operation should be done well.
Maintenance test is necessary to be done one time for one year with good test records.

When there is power fault, the solution refers to “common fault solution” part of this
operation manual.

11.11 Package, Transportation and Storage

11.11.1 Package

This equipment adopts carton packing with internal shockproof pad and damp proof plaster
bag.

11.11.2 Transportation

The products transportation should be done with good package. During the transportation,
severe shock and collision should be avoided, as well as moisture condition and be caught in the

67
rain

11.11.3 Storage

The storage environment : 5℃ ~ 30℃, relative humidity 70%, no corrosive gas, good
ventilation, 12 months storage period.

11.12 Open-case Inspection Item

According to packing list to check technical documentation and accessories:

a) operation manual;

b) quality of certificate;

c) AC input cable (TJ20/3P-449DL-1800mm) 1 pc.

68