Enterprise Elec 1 MW 2017 Test Report OET
Enterprise Elec 1 MW 2017 Test Report OET
Enterprise Elec 1 MW 2017 Test Report OET
GENERAL REMARKS........................................................................................ 3
EUT SPECIFICATION ....................................................................................... 4
TEST SETUP INFORMATION ............................................................................. 4
TEST REPORT SUMMARY ................................................................................. 5
RF POWER OUTPUT ........................................................................................ 6
Test Data: Measurement Table.............................................................................. 6
MODULATION CHARACTERISTICS .................................................................... 7
Test Data: Measurement Table.............................................................................. 7
Test Data: 0.5 uS Pulse width Plot ......................................................................... 8
Test Data: 0.5 uS Rep Rate Plot ............................................................................ 9
Test Data: 0.8 uS Pulse width Plot ....................................................................... 10
Test Data: 0.8 uS Rep Rate Plot .......................................................................... 11
Test Data: 1 uS Pulse width Plot.......................................................................... 12
Test Data: 1 uS Rep Rate Plot ............................................................................. 13
Test Data: 2 uS Pulse width Plot.......................................................................... 14
Test Data: 2 uS Rep Rate Plot ............................................................................. 15
OCCUPIED BANDWIDTH ................................................................................ 16
Test Data: Measurement Table............................................................................ 16
Test Data: 0.5 uS 99% OBW Plot ........................................................................ 17
Test Data: 0.8 uS 99% OBW Plot ........................................................................ 18
Test Data: 1 uS 99% OBW Plot ........................................................................... 19
Test Data: 2 uS 99% OBW Plot ........................................................................... 20
SPURIOUS EMISSIONS AT ANTENNA TERMINALS (CONDUCTED) ....................... 29
Test Data: Measurement Table............................................................................ 29
FIELD STRENGTH OF SPURIOUS EMISSIONS ................................................... 30
Test Data: Measurement Table............................................................................ 30
FREQUENCY STABILITY ................................................................................. 31
Test Data Measurement Table ............................................................................ 31
EQUIPMENT LIST ......................................................................................... 32
GENERAL REMARKS
The attached report shall not be reproduced except in full without the written
permission of Timco Engineering Inc.
Summary
Attestations
This equipment has been tested in accordance with the standards identified in this
test report. To the best of my knowledge and belief, these tests were performed
using the measurement procedures described in this report.
All instrumentation and accessories used to test products for compliance to the
indicated standards are calibrated regularly in accordance with ISO 17025
requirements.
Tested by:
Name and Title: Cory Leverett, Project Manager/Testing Technician
Date: 04/17/2017
Date: 4/18/2017
The EUT was tested under normal temperature and humidity. The
Test Condition
temperature was 20-26ºC with a relative humidity of 35 - 55%.
Modifications None
The EUT was transmitting a modulated pulse with a 2 us pulse at a 500 Hz
Test Exercise rep rate, with the exception of frequency stability testing in which CW signal
was used.
Regulatory
FCC CFR 47 Part 2, 90
Standards
Measurement TIA_603-D:2010,
Standards ITU-R M.1177-4 (04/2011), CISPR 16-2-3 ED 3.1
Setup Diagram:
Notes: The EUT has 2 transmitters; all conducted measurement results are summed
and compared to the limit following the procedures listed above
Pa = Pm*DC
Setup Diagram:
Pulse
Pulse Pulse rep.
widths
Type rate (Hz)
(μs)
0.5 uS 0.57 950
0.8 uS 0.89 750
1.0 uS 1.02 750
2.0 uS 2.08 500
IN1
90 1MAX 1MA
1 1
80
P0
70
60
50
40
30 TR
25
Center 3.525 GHz 200 ns/
IN1
90 1 1 1MA
80
P0
70
60
50
40
30 TR
25
Center 3.525 GHz 130 æs/
1 1 IN1
80 1MA
70
P0
60
50
40
30
20 TR
15
Center 3.525 GHz 200 ns/
IN1
80 1MA
70
P0
60
50
40
30
20 TR
15
Center 3.525 GHz 150 æs/
TRG
70
IN1
60 1MA
50
P0
40
30
20
10
0 TR
-5
Center 3.55 GHz 300 ns/
IN1
60 1MA
50
P0
40
30
20
10
0 TR
-5
Center 3.55 GHz 300 æs/
TRG
70
IN1
60 1VIEW 1MA
50
P0
40
30
20
10
0 TR
-5
Center 3.55 GHz 500 ns/
IN1
60 1MA
50
P0
40
30
20
10
0 TR
-5
Center 3.55 GHz 300 æs/
OCCUPIED BANDWIDTH
Setup Diagram:
40
30
1
20
10
0
-5
Center 3.525 GHz 3.5 MHz/ Span 35 MHz
Date: 11.APR.2017 14:03:47
T1
50
P0
T2
40
30
1
20
10
0
-5
Center 3.525 GHz 2.5 MHz/ Span 25 MHz
Date: 11.APR.2017 14:11:18
T1
50 T2
P0
40
30
1
20
10
0
-5
Center 3.55 GHz 2.5 MHz/ Span 25 MHz
Date: 11.APR.2017 15:26:20
T1 T2
50
P0
40
30
20
10
0
-5
Center 3.55 GHz 2 MHz/ Span 20 MHz
Date: 11.APR.2017 15:29:52
Procedure: The spectrum was scanned from9 KHz - 40 GHz. The measurements
were made in accordance with standard that is listed above.
The mean power was calculated based on the standard formula for radar systems:
Pa = Pm* Td * fr. Where Td is pulse duration, Pm is peak power, and fr is pulse rep rate.
Setup Diagram:
Tuned
Peak Power Peak Power Limit
Frequency
(dBm) (W) (dBc)
(MHz)
3525 89.92 981747.94 102.92
Emission
Level Level Margin
Frequency
(dBm) (dBc) (dB)
(MHz)
7050 -27.93 117.85 14.93
10575 -46.35 136.27 33.35
14100 -45.16 135.08 32.16
17625 -46.51 136.43 33.51
21150 -38.43 128.35 25.43
24675 -35.86 125.78 22.86
28200 -27.16 117.08 14.16
35250 -38.61 128.53 25.61
31725 -32.56 122.48 19.56
Procedure: The tabulated data shows the results of the substitution measurement
of radiated field strength emissions test. The spectrum was scanned
from 9 KHz - 40 GHz.
Setup Diagram:
Tuned FCC
Power Mode Peak Peak Power Measured BW
Frequency Requirement
(Hi/Lo) Power(dBm) (Watts) (MHz)
(MHz) (dB)
3525 Hi 89.92 981747.94 102.92 8.91
Emission Ant.
ERP (dBm) Below Carrier (dBc) Margin
Frequency (MHz) Polarity
7,050.00 V -48.3 138.22 35.30
10,575.00 V -55.7 145.62 42.70
14,100.00 V -36.1 126.02 23.10
17,625.00 H -65.5 155.42 52.50
21,150.00 V -66.5 156.42 53.50
24,675.00 H -69.5 159.42 56.50
28,200.00 H -60.5 150.42 47.50
31,725.00 H -60.3 150.22 47.30
35,250.00 H -58.9 148.82 45.90
Procedure: The test procedures used are detailed in the standard that is listed
above.
Notes: The EUT was too large to fit inside Thermal chamber; the frequency
generating components only were placed inside the thermal chamber
for this test as shown in the test setup photo
Frequency
Temperature MHz Cycles PPM
25°C (reference) 3464.971172
-30°C 3464.971827 655 0.189
-20°C 3464.971708 536 0.155
-10°C 3464.971559 387 0.112
0°C 3464.971405 233 0.067
10°C 3464.971223 51 0.015
20°C 3464.971150 -22 -0.006
30°C 3464.970864 -308 -0.089
40°C 3464.970801 -371 -0.107
50°C 3464.970314 -858 -0.248
END OF REPORT