1. EARTH WORK
1.1 Earthwork in excavation for foundations, in all types of soils like loose earth, moorum, over
burdens, etc., for depth up to 2.5m including of bottoms and disposal/stacking of the
excavated soil, within a dressing of sides and ramming lead of 100m as directed by
Engineer-in-Charge, providing temporary supports to existing service lines like water pipes,
sewers, cables, etc., including pumping subsurface and rainwater complete.
1.2 Earthwork in backfilling in/around foundations, below grade slabs etc., to proper grade and
level with selected materials from available excavated soil, including re-excavating the
excavated earlier, breaking clods, laying at all depths of thickness not exceeding 150mm,
watering, rolling and ramming by manual/ mechanical to achieve 90% laboratory max dry
density, dressing, trimming etc., all complete as per specifications, drawings and as directed
by the Engineer-in-Charge.
a) For Foundations Cum
d) Staircases (M 30)
i) Staircase 1 Cum
d) Staircases (M 30)
i) Staircase 1 Cum
v) Staircase 5 Cum
d) Staircases (M 30)
i) Staircase 1 Cum
v) Staircase 5 Cum
v) Staircase 5 Cum
d) Staircases (M 30)
i) Staircase 2 Cum
d) Staircases (M 30)
i) Staircase 2 Cum
v) Staircase 7 Cum
d) Staircases (M 30)
i) Staircase 2 Cum
v) Staircase 7 Cum
e) Lift Shear Walls (200mm thick) (M 45) Cum
d) Staircases (M 30)
i) Staircase 2 Cum
v) Staircase 7 Cum
d) Staircases (M 30)
i) Staircase 3 Cum
d) Staircases (M 30)
i) Staircase 3 Cum
d) Staircases (M 30)
i) Staircase 3 Cum
d) Staircases (M 30)
i) Staircase 3 Cum
d) Staircases (M 30)
i) Staircase 3 Cum
v) Staircase 11 Cum
d) Staircases (M 30)
i) Staircase 8 Cum
d) Staircases (M 30)
i) Staircase 8 Cum
d) Staircases (M 30)
i) Staircase 8 Cum
d) Staircases (M 30)
i) Staircase 8 Cum
d) Staircases (M 30)
ii) Staircase 8 Cum
v) Staircase 11 Cum
f) LMR Cum
i) Slab Cum
j) Wall Cum
d) RC Beams Sq m
e) Staircases
i) Staircase 1 Sq m
ii) Staircase 2 Sq m
iii) Staircase 3 Sq m
iv) Staircase 4 Sq m
v) Staircase 5 Sq m
vi) Staircase 6 Sq m
i) Ramp (Beams) Sq m
j) Ramp (Slab) Sq m
e) RC Beams Sq m
f) Staircases
i) Staircase 1 Sq m
ii) Staircase 2 Sq m
iii) Staircase 3 Sq m
iv) Staircase 4 Sq m
v) Staircase 5 Sq m
vi) Staircase 6 Sq m
i) Retaining wall Sq m
j) Ramp (Beams) Sq m
k) Ramp (Slab) Sq m
3.3 Basement 2 (3.5 m. Floor Height)
a) Columns Sq m
e) RC Beams Sq m
f) Staircases
i) Staircase 1 Sq m
ii) Staircase 2 Sq m
iii) Staircase 3 Sq m
iv) Staircase 4 Sq m
v) Staircase 5 Sq m
vi) Staircase 6 Sq m
i) Retaining wall Sq m
j) Ramp (Beams) Sq m
k) Ramp (Slab) Sq m
e) RC Beams Sq m
f) Staircases
i) Staircase 1 Sq m
ii) Staircase 2 Sq m
iii) Staircase 3 Sq m
iv) Staircase 4 Sq m
v) Staircase 5 Sq m
vi) Staircase 6 Sq m
i) Retaining wall Sq m
j) Ramp (Beams) Sq m
k) Ramp (Slab) Sq m
g) Staircases
i) Staircase 2 Sq m
ii) Staircase 3 Sq m
iii) Staircase 4 Sq m
iv) Staircase 5 Sq m
v) Staircase 7 Sq m
e) Drops Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 2 Sq m
ii) Staircase 3 Sq m
iii) Staircase 4 Sq m
iv) Staircase 5 Sq m
v) Staircase 7 Sq m
h) Lift Shear Walls (200 mm thick) Sq m
e) Drops Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 2 Sq m
ii) Staircase 3 Sq m
iii) Staircase 4 Sq m
iv) Staircase 5 Sq m
v) Staircase 7 Sq m
d) Drops Sq m
e) RC Beams Sq m
f) Staircases
i) Staircase 2 Sq m
ii) Staircase 3 Sq m
iii) Staircase 4 Sq m
iv) Staircase 5 Sq m
v) Staircase 7 Sq m
f) Drops Sq m
g) RC Beams Sq m
h) Staircases
i) Staircase 3 Sq m
ii) Staircase 4 Sq m
iii) Staircase 5 Sq m
iv) Staircase 7 Sq m
e) Drops Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 3 Sq m
ii) Staircase 4 Sq m
iii) Staircase 5 Sq m
iv) Staircase 7 Sq m
e) Drops Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 3 Sq m
ii) Staircase 4 Sq m
iii) Staircase 5 Sq m
h) Lift Shear Walls (200 mm thick) Sq m
e) Drops Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 3 Sq m
ii) Staircase 4 Sq m
iii) Staircase 5 Sq m
e) Drops Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 3 Sq m
ii) Staircase 4 Sq m
iii) Staircase 5 Sq m
d) Drops Sq m
e) RC Beams Sq m
f) Staircases
i) Staircase 5 Sq m
ii) Staircase 8 Sq m
iii) Staircase 9 Sq m
iv) Staircase 10 Sq m
v) Staircase 11 Sq m
g) Drops Sq m
h) RC Beams Sq m
i) Staircases
i) Staircase 8 Sq m
ii) Staircase 9 Sq m
iii) Staircase 10 Sq m
iv) Staircase 11 Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 8 Sq m
ii) Staircase 9 Sq m
iii) Staircase 10 Sq m
iv) Staircase 11 Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 8 Sq m
ii) Staircase 9 Sq m
iii) Staircase 10 Sq m
iv) Staircase 11 Sq m
f) RC Beams Sq m
g) Staircases
i) Staircase 8 Sq m
ii) Staircase 9 Sq m
iii) Staircase 10 Sq m
iv) Staircase 11 Sq m
b) Slab Sq m
c) RC Beams Sq m
d) Staircases
i) Staircase 8 Sq m
ii) Staircase 9 Sq m
iii) Staircase 10 Sq m
iv) Staircase 11 Sq m
f) LMR Sq m
h) Swimming Pool Sq m
i) Slab Sq m
j) Wall Sq m
TOTAL OF SHUTTERING
4. REINFORCEMENT STEEL
Collecting from the Owners stores at site, providing & fixing reinforcement for RCC work
with high yield strength, ribbed cold twisted tor steel (HYSD) bars of various diameters &
grade of steel as specified below, conforming to IS or equivalent BS specifications, including
cutting & waste, bending, hoisting, fabricating & placing in position according to the
drawings, & binding the reinforcement with galvanized annealed binding wire of double fold
of 18 gauge & providing, cover blocks for placing the reinforcement in position & maintaining
the cover specified and/or according to relevant IS or equivalent BS code. Note: Unless
noted otherwise, the measurements in according IS 1200 or equivalent BS. However,
reinforcement shall be measured in lengths of bars as actually placed in position on
standard weight basis, no allowances being made for the weight for rolling margin.
Authorized laps & splices will be measured, change in any shape & profile, spacers bars of
any shape and profile, cover blocks, wastage & binding wire will not be measured & shall be
included in the quoted rates.
Quoted rates to include lead & lift, placing at all levels & as directed.
4.1 Column Footings & Lift base M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
c) RC Beams M.T
d) Staircases M.T
b) Slab M.T
c) RC Beams M.T
d) Staircases M.T
g) LMR M.T
4.22 Providing and fixing Mechanical Splicing using threaded coupler to the reinforcement bars of
specified dia and grade using high yield strength standard couplers of specially produced
steel to join ribbed bearing bars machine cut end to end. Cost to include necessary supply
of threaded couplers of various diameters, reducing diameters,transportation,copling at site
by mechanical means, erection at site,testing of random samples,testing at site,protection of
threaded ends using PVC covers,etc., complete.Cost to include necessary testing of joints
at site using ultrasonic methods required by Consultants at intervals.Approved Makes
Moment/Dextra
(a) Y32 and Y32 to Y25 Nos
5.2 Extra over item No. 5.1 above for creating 200 mm wide cavity including providing and fixing Sq m
approved hot dip GI ties as anchors for cavtity wall at spacing of 900mm c/c horizontal and
450mm c/c vertical in the cavity
5.3 Providing and constructing 150mm thick light weight concrete block masonry (SIPOREX or Sq m
BILT or equivalent as approved), blocks conforming to IS 2185 (Part-III) in cement mortar
CM 1:4 (1 cement : 4 sand) mixed with approved non-shrinking compound as per
manufacturer’s instruction, including providing RCC patli beam of 150mm x 100mm at every
1.00m c/c with 2 nos. 8 mm dia Tor bars and 6 mm dia links at 300 c/c in cement concrete
of mix M 20, required formwork complete with raking out joints, curing, doing independent
double legged scaffolding as per specifications etc. at heights, depths and leads as directed
by EIC to his entire satisfaction. (Patli beam is part of the item)
5.4 Extra over item No. 5.3 above for providing RCC mullions 150mm x 150mm thick at Sq m
2000mm c/c with 4 Nos 10mm dia tor bars and 8mm dia tor rings @ 200mm c/c
5.5 Providing and constructing 100mm thick light weight concrete block masonry (SIPOREX or Sq m
BILT or equivalent as approved), blocks conforming to IS 2185 (Part-III) in cement mortar
CM 1:4 (1 cement : 4 sand) mixed with approved non-shrinking compound as per
manufacturer’s instruction, including providing RCC patli beam of 100mm x 100mm at every
1.00m c/c with 2 nos. 8 mm dia Tor bars and 6 mm dia links at 300 c/c in cement concrete
of mix M 20, required formwork complete with raking out joints, curing, doing independent
double legged scaffolding as per specifications etc. at heights, depths and leads as directed
by EIC to his entire satisfaction. (Patli beam is part of the item)
5.6 Extra over item No. 5.5 above for providing RCC mullions 100mm x 100mm thick at Sq m
2000mm c/c with 4 Nos 10mm dia tor bars and 8mm dia tor rings @ 200mm c/c
5.7 Providing and constructing 100mm thick solid concrete block masonry in sub and Sq m
superstructure with approved quality site made blocks having minimum crushing strength 35
Kg/Sq. cm and maximum water absorption 10%, in cement mortar mix ratio CM 1:4 (1
cement : 4 Sand) mixed with approved non-shrinking compound, doing masonry in specified
courses, also providing RCC patli beam of 100mm x 100 mm at about 1.00m C/C with 2
nos. 8 mm dia Tor bars and 6 mm dia links at 300 c/c in cement concrete of grade M 20,
required formwork, complete with raking out joints, curing, doing independent double legged
scaffolding, complete as per specifications etc. at all heights, depths and leads and as
directed by EIC to his entire satisfaction. (Patli beam is part of the item)
5.8 Providing and constructing solid concrete block masonry in sub and superstructure with
approved quality site made blocks having minimum crushing strength 35 Kg/Sq. cm and
maximum water absorption 10%, in cement mortar mix ratio CM 1:5 (1 cement: 5 Sand)
mixed with approved non-shrinking compound, doing masonry in specified courses,
complete with raking out joints, curing, doing independent double legged scaffolding,
complete as per specifications etc. at all heights, depths and leads and as directed by EIC to
his entire satisfaction.
a) 150mm thick Sq m
b) 200mm thick Sq m
5.9 Providing and constructing half brick (115mm thick) masonry with locally available approved Sq m
quality bricks having minimum crushing strength 35 Kg/Sq. cm and maximum water
absorption 20%, in cement mortar CM 1:4 (1 cement : 4 Sand) mixed with approved non-
shrinking compound as per manufacturer’s instruction in specified courses of approved
bond and including providing RCC patli beam of 115mm x 100 mm at every 1.00m c/c with 2
nos. 8 mm dia Tor bars and 6 mm dia links at 300 c/c in cement concrete of mix M 20,
required formwork complete with raking out joints, curing, doing independent double legged
scaffolding as per specifications etc. at heights and leads all as directed by EIC to his entire
satisfaction. (Patli beam is part of the item)
5.10 Providing and constructing 230mm or more thick masonry with locally available approved Cum
quality bricks having minimum crushing strength 35 Kg/Sq. cm and water absorption
maximum 20% in cement mortar CM 1:6 (1 cement : 6 Sand) mixed with approved non-
shrinking compound as per manufacturer’s instruction in specified courses of approved
bond and including raking out joints, curing, doing independent double legged scaffolding,
all complete as per specifications etc. at all heights, depths and leads all as directed by EIC
to his entire satisfaction.
TOTAL OF MASONRY WORK
6. PLASTERING WORK
6.1 Providing and applying 12mm thick plaster in cement mortar mix ratio CM 1:4 (1 cement : 4 Sq m
sand) mixed with approved polypropylene fibers; to internal surfaces of concrete and
masonry work; including raking out joints, hacking concrete surfaces and applying approved
chemical bonding agent for receiving scratch/dash coat palster & curing for creating a
possitive bond, preparing junctions of concrete/masonry by neat cleaning, pointing/grouting
using non-shrink mortar and further grouting junctions by pressing square crush aggregate;
also providing and fixing 26 gauge (20mm x 20mm size) chicken mesh @ 150mm wide to
junctions of concrete and masonry, preparing jambs, sills, grooves, pattas, wattas,
rounding of corners, etc. all complete as per architectural drawings, specifications and
finished smooth with wooden rundha etc. or as specified by the Architect/EIC; at all leads,
depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing,
etc. complete as per specification and to the approval of the EIC. (To internal walls)
6.2 Providing and applying 8mm to 10mm thick plaster in cement mortar mix ratio CM 1:4 (1 Sq m
cement : 4 sand) mixed with approved fibers as per recommendations of the approved
manufacturer, to internal surfaces of concrete work; including hacking concrete surfaces
then applying approved chemical bonding agent and applying scratch / dash coat plaster &
curing, for creating a possitive bond, preparing junction of concrete by neat cleaning ,
preparing grooves, pattas, wattas, rounding of corners, etc. all complete as per architectural
drawings, specifications and finished smooth with wooden rundha etc. or as specified; at all
leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces,
curing, etc. complete as per specification and to the approval of the EIC. (to internal
ceilings)
6.3 -Do- as per item no. 6.1 & 6.2 but to walls/ceilings of ducts and inside the boxing masonry Sq m
including adding approved waterproofing compound 2% by weight of cement or as directed
by the EIC to his entire satisfaction. (To ducts)
6.4 Providing and applying minimum 25 mm thick double coat cement sand plaster mixed with Sq m
approved fibers & non-shrinking compound as instructed by approved manufacturer, first
coat to be 15 mm thick cement sand mortar of mix ratio 1:4 (1 cement : 4 sand) including
adding 2% by weight of cement approved waterproofing compound. Second coat to be 10
mm thick in cement sand mortar of mix ratio 1:3 (1 cement : 3 sand) and sand face finished
or as required to receive specified architectural external finish, to correct line, plumb and
level to external faces of walls, sofits/ceiling if any, including racking out junctions of
masonry and concrete and other dissimilar materials, treated by pointing and grouting using
non-shrinking compound and further grouted with square cut stone at junction, then
providing 150 mm wide 26 gauge (20mm x 20mm size) GI chicken mesh at treated
junctions of masonry work, hacking closely concrete surfaces, apply chemical adhesive
coating to concrete surfaces and then apply a scratch coat plaster (prior to main plaster for
positive bond), independent double legged scaffolding etc.
Item also include plastering to precast concrete window sills, RCC cornices, making wattas,
drip moulds, pattas, grooves (other than specially listed hereunder),etc.,doing curing,
cleaning, etc. all complete to the approval of the EIC.
7.2 Providing, machine mixing and laying in approved panels of 50 mm thickness Indian patent Sq m
floor in cement concrete mix of 1:2:4 (1 cement :2 sand :4 aggregate 12.5 mm) well
vibrated, compacted including 45 x 3 mm thick glass dividing strip, fixed to correct level and
finished smooth and cured by keeping surfaces well- covered and protected against
excesses of any type. (The contractor will provide for preparation or surface by cleaning,
hacking and exposing aggregate to achieve the best bond, and any curling, lifting or
debonding noticed shall be rectified by the contractor at his cost), all complete at all heights
and leads to the satisfaction of the EIC.
7.3 Providing and laying 25mm thick machine cut, machine polished approved Kota stone Sq m
flooring in pattern and size as detailed in drawing or as directed by the EIC. Stone to be
bedded in cement sand mortar mix ratio 1:6 (1 cement : 6 sand) including cleaning and
preparing the surface for bedding, spreading neat cement slurry by using minimum cement
about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about
4.5 kg/sqm over bedding, joints to be cleaned and grouted with matching colour approved
quality readymade grout, curing, cleaning, etc. to required line, level, etc. machine polishing
all complete at all heights and leads to the satisfaction of the EIC. (Services areas, Stairs
landings, Basement Service Area)
7.4 Providing and fixing 19mm thick approved Kota stone skirting as shown in drawing or as
directed by the EIC. Stone fixed by approved tile adhesive (Bal or Laticrete or equivalent
approved) to correct line, level and plumb. Joints are well cleaned and grouted with
matching colour approved readymade grout and cured, cleaned, machine / hand polishing
(if required by the EIC) and including finishing junction of plaster etc. all complete at all
heights and leads to the satisfaction of the EIC.
a) 100mm high Rmt
7.5 - Do - as per item no. 7.4 but Kota stone skirting about 100mm high in perpendicular from Rmt
top of nosing in inclined profile parllel to the stair waist slab as detailed in drawing or as
directed by the EIC, skirting covering three steps with single piece stone etc all complete at
all heights and leads to entire satisfaction of the EIC.
7.6 Providing and fixing about 275mm wide and 30mm thick approved Kota stone treads in one Rmt
piece or as directed to full length of step and machine cut, machine polished. Treads to be
rounded at front and all exposed edges machine polished. Further treads to have 2 nos.
6mm x 3mm deep grooves on top at front or as detailed in drawing. Treads to be bedded in
cement mortar mix ratio 1:6 (1 cement : 6 sand) including preparing and cleaning surfaces,
spreading cement slurry using minimum cement 2 kg/sqm over prepared surface and 4.5
kg/sq m over bedding, joints to be cleaned and grouted with matching colour approved
readymade grout, curing, cleaning, mirror polishing (machine/hand polishing again if
required by EIC) etc. all complete at all heights and leads to the approval of the EIC.
7.7 Providing and fixing 19 mm thick and about 150mm high approved Kota stone risers Rmt
machine cut and machine polished in one piece or as directed, to full length of step, stone
fixed by approved adhesive on back, to correct line, level and plumb. Joints are well
cleaned grouted with matching colour approved readymade grout, curing, mirror polishing
(machine/hand polishing again if required by EIC) , cleaned and where specified or shown in
drawing exposed edge of stone rounded / chamfered and polished all complete to the
satisfaction of the EIC.
7.8 Providing and laying approved quality, colour, design and shade Anti-skid Ceramic tiles Sq m
(confirming to IS 13755) (Basic Rate - Rs. 450/- per Sqm) flooring in pattern as detailed in
drawing or as directed by the EIC. Tile to be bedded in cement sand mortar mix ratio 1:6 (1
cement : 6 sand) including cleaning and preparing the surface for bedding, spreading neat
cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading
cement paste using minimum cement about 4.5 kg/sqm over bedding, joints to be cleaned
and grouted with matching colour approved readymade grout, curing, cleaning, etc. to
required line, level, etc. all complete at all heights and leads to the satisfaction of the EIC.
(Toilets)
7.9 Providing and fixing approved quality, colour, design and shade Glazed Ceramic tiles,
confirming to IS 13753 , to walls fixed in pattern as per the architectural drawing or as
directed by the EIC. Tiles fixed by approved tile adhesive (Bal or Laticrete or equivalent
approved) to correct line, level and plumb. Joints are well cleaned and grouted with
matching colour approved readymade grout and cured, cleaned and including finishing
junction of plaster etc. all complete at all heights and leads to the satisfaction of the EIC.
a) Glazed Cetramic Tiles of size 200mm x 300mm (Basic Rate - Rs.350/Sqm) (Service Sq m
Corridor, Service Area toilets, Kitchen)
7.10 Providing and fixing wash basin counter with 19 mm thick machine cut, mirror polished of Rmt
approved Granite Stone (Basic Rate - Rs. 1650/- per Sqm) in approved design about 600
mm wide fixed over 25mm thick Cudduppa stone, 100mm high marble fascia, fixed with
required supports, pins, clamps, GI brackets if any, grouted in wall, including cutting and
finishing smooth and mirror polishing Cudduppa and Marble for wash basin, required
sealing with silicone sealant etc. all complete as detailed in drawing or as directed by the
EIC to his entire satisfaction.
7.11 Providing and fixing 19 mm thick about 450mm wide and 1200mm high, approved Granite Nos.
urinal partitions machine cut mirror polished on all exposed faces and edges polished and
semi rounded; fixed to wall including required pins, clamps, grouted and sealed etc.
complete as per detailed Architectural drawing to entire satisfaction of the EIC.
8.2 Supplying and installing MS fabricated gratings for storm water drains/ramp drains/catch Sq.M
basins using ISA 50x50x6mm angles for outer frames and MS flats of 40x6 @ 50mm c/c
bothways as per detailed drawings. The cost to include Zincalumion primer and two coats of
enamel /zinchrome paint etc complete.
8.3 Supplying and fixing MS Ladder for Lift machine, OHT using MS sections and angles with No.
necessary supports of same angle Iron as per design and drawing Including handrailing on
both sides and with angle Iron props at regular interval and required height including fixing
with CC 1:2:4 and two coats of non poisonous anticorrosive bituminous paint complete with
all leads & lift and as directed by Consultant.
9.3 Providing and filling Brick bat (40-60 mm) with cement mortar mixed in ratio 1:3:6 (1 cement Cu m
: 3 sand : 6 brick bats) including mixing of water proofing compound 4 % by weight of
cement to sunk portions of toilets, kitchen projection, terraces etc. complete to the entire
satisfaction of the EIC. Toilet / Sunk portion shall be tested by ponding water for 72 hrs.
9.4 Designing, providing and installing proprietary crystalline waterproofing system to inside Sq m
surfaces of the water retaining structures (U.G Water Tanks)
- System shall consist of preparation of surfaces including ‘V’ grooves at junctions and
joints, pressure grouting the same and curing.
- Applying crystalline waterproofing compound one / two coat at specified intervals and as
recommended by manufacturer and allowed to cure.
- Walls plastering and finished smooth with about 15mm thick with cement sand mortar 1:4
(1 cement : 4 sand) using 2% of waterproofing compound by weight of cement.
9.5 Providing and applying membrane water proofing to terrace through approved agencies Sq m
consisting of (Landscape terrace garden)
a) Cementious based chemical waterproofing coating (two / three coats) system including
preparation of surfaces to receive approved chemicals, curing
b) Perlite concrete of density 450 kg/cum and of minimum 75 mm thickness at draining point
and rest area sloped to drain water as detailed in drawing.
c) 3.2 mm thick APP Polymer modified polyester reinforced (Garden Moply FP 4) of Texsa
Ltd. or equivalent approved.
d) Membrane protected by 30 mm thick water proof screed in CM mix ratio (1:4) spread
over entire terrace area and finished to receive Architectural finish. Walls plastered with 12
mm thick CM 1:4. Work to include adding Polypropylene Fibermesh fibers with Microban to
mortar in proportion recommended by the manufacturer
with use of approved products and work carried out as per approved shop drawings,
instructions and specifications of the manufacturer of product. Also include required
preparation of the surface, etc. testing by pounding water for 72 hours and giving guarantee
for 10 years on Rs.100/- Stamp paper in approved proforma.
9.6 Designing, providing and installing average 110mm thick proprietary terrace waterproofing Sq m
consisting of brickbat coba in cement mortar mix in ratio of 1:5 (1 cement : 5 sand) with
approved waterproofing compound at the rate as specified by approved manufacturer to
terrace, chajjas etc. including applying to cleaned, grouted concrete base surface,
proprietary chemical water proofing system consisting of polymer modified acrylic base
composite coating (of one part or two part component) as approved by the EIC and as
recommended by the approved manufacturer of waterproofing coating, and laying brick bat
to required slope; outlet and rain water pipes grouted (minimum thickness 75mm), further
finished with China mosaic in pattern and size as approved by EIC, joints grouted with
waterproof jointing compound of approved colour and pattern all complete as per
specifications as detailed and as approved by the EIC;
system to be carried over parapet wall about 300mm high from finish floor level. testing by
ponding water about 200 mm high for 72 hrs. protecting till handover, testing for heat
insulation etc. all complete as per specifications or equivalent as approved by the EIC;
contractor to provide guarantee for 10 years on Rs.100/- stamp paper in approved proforma.
(At main terrace)
9.7 -Do- as per Item No. 9.6 above but finished with 50mm thick IPS in cement concrete 1:2:4, Sq m
finished smooth or as required ready to receive floor finish.
9.8 Extra over Item No. 9.6 above for average thickness more than 110mm Cu m
10.1.2 Supplying and installing MS fabricated gratings for storm water drains/ramp drains/catch Sq.M
basins using ISA 50x50x6mm angles for outer frames and MS flats of 40x6 @ 50mm c/c
bothways as per detailed drawings. The cost to include Zincalumion primer and two coats of
enamel /zinchrome paint etc complete.
10.2 Providing and laying 20mm grade aggregate for sub-soil drainage system to the specified Cu.M
width and depths as indicated in the drawing, cost shall include necessary lead and lift etc,
complete.
10.3.2 Filling and sealing the expansion joint with Silicon Sealant, necessary backer rod, sealing Rm
tape as per details/drawings. Sealant shall be of the Gun grade either single or two part
component capable of withstanding repeated extensions, compressions, vibrations, and
cyclic movements without loss of adhesion and resist deterioration by weathering, sunlight,
ozone, water, salt, oil, fuels, acids, and most of the commonly used chemicals etc complete
with min 50% movement capacity.
10.4 Providing and laying 600 micron guage Polythene paper / Polythene sheet below Grade Sq m
slab, PCC, Raft slab etc. to the required levels, including supply, loading and unloading,
storing, transportation, laying, sealing of junctions and overlaps, all leads and lifts etc
complete.
10.5 Installing open well dewatering system for both ground and surface water, removal of LS
slurry generated while excavation and keeping the water table always below the excavated
level, the excavated area free of water, dewatering to be continued till the completion of
Ground floor slab.
10.6 Providing Core cutting in slabs/beams/retaining walls and any other RC members to any Sq m
dia & depth by using diamond rilling machine with tolerance for any type of inserts, anchor
fasteners etc. Rate shall include for all charge, preperation of surface, cutting of
reinforcement, cleaning the surface, staging, scaffolding, application of necessary
chemical/foil as per manufacturers specification, with necessary tools and equipments,
water and power, removal of debris from the site, staging, scaffolding etc complete, as
directed.
10.8 Structural Steel Works: Providing, Fabricating and fixing in position structural steel M.T
conforming to IS 800 as Gusset Plates, Stiffener plates, Brackets, Bolts, Cleats, seating
angles, corner angles, insert plates wherever specified as per drawings. Cost to include
welding of members using structural steel welding electrodes as per IS 814/816/817, testing
as per IS 7307 (Part 1), necessary equipments , tools and tackles, staging, scaffolding
required, preparation of shop drawings & approval etc , complete including a coat of zinc
chromate primer painting.
10.9 Supplying and fixing MS Ladder for Lift machine, OHT using MS sections and angles with Nos.
necessary supports of same angle Iron as per design and drawing Including handrailing on
both sides and with angle Iron props at regular interval and required height including fixing
with CC 1:2:4 and two coats of non poisonous anticorrosive bituminous paint complete with
all leads & lift and as directed by Consultant.
10.11 Supplying, drilling and fixing MS anchor rod of 16mm dia into the hard rock for 200mm Nos.
below footing and 200mm anchoring into the footing. Rate shall include for material for
Cement grouting and labour etc complete.
10.12 Providing and doing 200mm thick dry rubble soling, voids filled with stone chips and Sq m
screened with stone dust / sand including compaction with mechanical vibratory compactor
complete to satisfaction of EIC.
10.13 Providing and injecting pre-construction chemical anti-termite treatment as per IS6313 that Sq m
shall create a chemical barrier under and around the foundation pits, below plinth, along
external perimeter of building (basement), surrounding of pipes, conduits, etc.; all complete
and conforming to specifications and as per approved manufacturer’s instructions and
recommendation, and installed by manufacturer’s approved agency with a guarantee of 10
years on Rs.100/- stamp paper in approved proforma, all to the satisfaction of the EIC. (Anti-
termite treatment should be carried out in number of steps and operation up to the plinth
level i.e. after getting the bottom level of foundation, at plinth level and at the time of back
filling around extra / work space of excavation for foundation, plinth beams, basements etc.
and plinth area in plan at ground level shall be measured once for payment of all necessary
operations).