Non-Segregated Phase Bus Duct
Capabilities
■ Increased Reliability: ■ Field Measurement Assistance:
Product Offering Insulated segregated phase For large and complex projects, ■ 600 V through 38 kV construction with aluminum Eaton can provide factory mea- ■ 1200 A through 5000 A enclosures for a 50-year life cycle. surement assistance for busway layouts. Please contact your local ■ Copper bus bar ■ Increased Safety: Eaton sales office for price and Built per ANSI/IEEE Standard C37.23. availability. ■ 130 degree Class B epoxy insulation ■ Reduced Installation Cost: ■ Crate By Run: Lower total installed costs versus Eaton will crate and ship your ■ Silver-plated contact surfaces traditional cable and conduit order by run, floor or any other ■ Up to 63 kA short circuit withstand installations. special specified shipping splits. ratings, 170 kA peak Contact your local Eaton sales ■ Aluminum, steel and stainless General Description office for price and details. steel enclosures ■ Isometric Drawing Tool: ■ Indoor, outdoor and dust-tight Eaton’s Cutler-HammerT non-segre- Need quick approval drawings. construction gated phase bus runs are designed Contact your local Eaton for use on circuits which importance sales office. requires greater reliability than Standards power cables provide. Typical of such applications are the connections from ■ The metal-enclosed non-segregated transformers to switchgear assemblies phase bus runs are designed in unit substations, connections from for 600 V, 5 kV, 15 kV, 27 kV and switchgear assemblies to rotating 38 kV service in accordance with apparatus, and tie connections ANSI C37.23. between switchgear assemblies. ■ Bus run assemblies are designed Non-segregated phase bus is an to meet Uniform Building CodeT assembly of bus conductors with (UBC) and California Building Code associated connections, joints and Title 24 for Seismic Zones 4.3.2a.2b.1. insulating supports confined within and 0. Completed guidelines for a metal enclosure without interphase proper supports are provided barriers. The conductors are on each seismic specified order. adequately separated and insulated ■ Certain bus ratings can be supplied from each other and grounded by with CSAT listing. insulating bus supports. Each conduc- tor for 2400 volt service and above is insulated with a fluidized bed Customer Value epoxy coating throughout which ■ Improved Uptime: reduces the possibility of corona Quick installation versus cable and electrical tracking. bus and traditional cable and conduit installations. Services & Programs ■ Improved Maintainability: ■ Final Field Fit: Re-usable and moveable, making This program is designed to field equipment layout and changes easier. measure a chosen unshipped section in a run and ship it in 5 to 10 work days to ensure an exact fit. See SA01701004E for program details. Technical Data The metal-enclosed non-segregated phase bus runs are designed for 600 V, 5 kV, 15 kV, 27 kV and 38 kV service in accordance with ANSI C37.23. ■ Temperature Rise: The bus will be capable of carrying rated current continuously without exceeding a conductor temperature rise of 65ºC above an outside Optional Optional ambient temperature of 40ºC, as Ground Bus Ground Bus required by ANSI Standard C37.23. 3-Phase, 3-Wire 3-Phase, 4-Wire ■ Test: 1200 – 3200 Amps 1200 – 3200 Amps 600 V 5 kV – 15 kV 600 V 5 kV – 15 kV The design of non-segregated bus runs has been tested per ANSI C37.23. Certification of momentary current testing, impulse testing, and heat rise are available upon request. ■ Seismic Application: Bus run assemblies are designed to meet Uniform Building CodeT (UBC) and California Building Code Title 24 for Seismic Zones 4.3.2a.2b.1. Optional Optional and 0. Completed guidelines for Ground Bus Ground Bus proper supports are provided on each seismic specified order. 3-Phase, 3-Wire 3-Phase, 4-Wire 4000 – 5000 Amps 4000 – 5000 Amps ■ Short Circuit Force 600 V 5 kV – 15 kV 600 V 5 kV – 15 kV Withstand Ability: The metal-enclosed non-segregated phase bus runs are designed to withstand electrical and mechanical forces generated by momentary (10 cycle) and short-time (2 second) short circuit currents in accordance with the latest ANSI/IEEE Standard C37.23. For 600 V application, 4- cycle momentary current withstand Optional Optional rating up to 158 kA peak (98.8 kA Ground Bus Ground Bus rms asymmetrical) is also available. 3-Phase, 3-Wire 3-Phase, 4-Wire ■ Third-Party Certification: 1200 – 2000 Amps 1200 – 2000 Amps Certain bus ratings can be supplied 27 kV 38 kV with CSAT listing.
Cutler-Hammer is a federally registered trademark of
Eaton Corporation. CSA is a registered trademark of the Canadian Standards Association. Uniform Building Code (UBC) is a trademark of the International Conference of Building Officials (ICBO). Cutler-Hammer is a federally registered trademark of Eaton Corporation.
Eaton Electrical Inc.
1000 Cherrington Parkway Moon Township, PA 15108 United States tel: 1-800-525-2000 www.EatonElectrical.com