5.3 Design of Waste Heat Boiler: (13) : Data

This document summarizes the design of a waste heat boiler. It provides calculations to determine: 1) The heat load of 1772.29 kW based on gas flow rate and temperature change. 2) A heat transfer area of 30.7 m^2 based on the heat load and a assumed heat transfer coefficient. 3) Tube dimensions including 87 tubes of 0.2245 m diameter arranged in a triangular pitch to fit in a 0.31257 m diameter shell.

Uploaded by

moni bee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views7 pages

5.3 Design of Waste Heat Boiler: (13) : Data

This document summarizes the design of a waste heat boiler. It provides calculations to determine: 1) The heat load of 1772.29 kW based on gas flow rate and temperature change. 2) A heat transfer area of 30.7 m^2 based on the heat load and a assumed heat transfer coefficient. 3) Tube dimensions including 87 tubes of 0.2245 m diameter arranged in a triangular pitch to fit in a 0.31257 m diameter shell.

Uploaded by

moni bee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 7

5.

3 Design of Waste Heat Boiler: (13)

Data:

Flow rate of gas = mg = F7 = 679.8 kmol/hr

Flow rate of cooling water = mw =

F8 = 137.2648 kmol/hr

Temperature of gas at inlet T1 = 678 K


Temperature of gas at outlet T2 = 450K
Temprature at Cooling Water Inlet=333K
Temprature at cooling water outlet=503 K
o
Specific heat of gas = Cpg = 1775 J/Kg - C

1. Heat Load:
Q = mg × Cpg× ∆Tg

Putting all above values we have,

= 1772.29 KW

2. Log mean Temperature Difference:


− )

= 144.3128K

3. Correction Factor for Temperature: ( − )

R=1.4

S=.492

Ft=0.8
Corrected temperature difference:

∆Tm= ∆Tlm FT

∆Tm = 115.2 k

1. Area:

Let us assume:

U = Overall heat transfer Co efficient


2
= 500 W/m – K (6)

A = Q/(U∆Tm)
2
= 30.7m
2. Tube Dimensions:

Let,
D0 = outer diameter = 25 mm
Di =inner dia = 18 mm
Length of tube = 7m (Range 1.83 – 7.32m)
Thickness of tube = 0.2m

Corrected length:

Corrected length= selected length- thickness of tube sheets = 6.8 m


1. Surface Area of one tube:

At = πd0 l
2
= 0.379 m
2. Number of Tubes:

No. of Tubes = Nt= A/At

= 87 tubes

1. Pitch of Tube:

For triangular pitch:

Pt = pitch = 1.25d0
= 31.25 mm

2. Bundle Diameter:
Db= d0( Nt/K1)1/n )

K1 = 0.249

n1 = 2.207

1/2.207
Db = 19 (58/0.249)
= 224.57mm

= 0.2245 m

1. Shell Bundle Clearance:

Let pull through floating head type exchanger is selected because temperature
difference is sufficient

Clearance = dia of shell – dia of tube


bundle Clearance= 88mm

DS = Db + Clearance
= 224.57 +88

DS = 312.57 mm

= 0.31257 m

1. Tube Side
Cross sectional area of tube:
2
Cross sectional area of tube = At = (π/4) ×di

= 254.34 m2
Tube per pass:
Tube per pass = Nt/2

= 43.5

Total flow area:

Af= Total flow area = tubes per pass × Ai


2
= 11063.2 m
Water linear velocity:

3
δ (Density of water) = 947 kg/m ut
water linear Velocity = wt /ρ × Af
= 0.42 m/s

Inside coefficient of water:

hi = 4200(1.35 + 0.02t) ut0.8 / di0.2


2 0
= 5976.2 W/m - C
Shell side :
1/3
hs = jh×(k/de)×Re×(Pr ) …….. (i)
3
ρ = (Density of shell fluid side at T) = 1.1304 kg/m
CP = Specific heat of shell side fluid at T = 1775/Kg-C k

Thermal conductivity of shell side fluid at T = 0.19

2
μ = viscosity of shell side fluid at T = 0.00054 Ns / m
Equivalent diameter: )

2 2
de= (1.1/19 ) (23.75- 0.917× 19 )
= 13.49095 mm
= 0.01349 m
Baffle Spacing:
Lb= baffle spacing = 0.2 × Ds
= 0.06255 m
Cross flow area:
As= cross flow area = (pt –d0) × Ds× Lb/ Pt
2
= 0.0400m

Linear Velocity of shell side Fluid:

us = wg / (ρ × As)

= 75.85 m/s

Reynolds Number:

Re = ρ de us/ μ

Re=7432
Prandtl Number:

Pr = Cp × k /μ
= 5.044737

2. Overall Heat Transfer Coefficient:

2 0
kw= thermal conductivity of tube material = 45 W/m - C
2 0
h0d = fouling Co efficient of shell side fluid = 3000 W/m - C hid = fouling Co
2 0
efficient of tube side fluid = 3000 W/m - C
20
hi = inside fluid film Coefficient = 2759.94 W.m - C

1/ U0 = 0.0134

2 0
U0 = 745.48 W/m - C
3. Tube Side pressure Drop:
Np= no. of tube passes

3
ρ = Density = 968 kg/m
ut= tube side velocity = 0.42 m/s

2
μ= viscosity of fluid at tube side at t = 0.000785 Ns/m
2
μw = viscosity of fluid at wall temperature Ns/m significant only for viscous fluid,
otherwise leaves it

m= 0.25 for laminar flow Re˂2100, 0.14 for turbulent flow Re>2100
( ) = 1 (significant only for viscous fluids, otherwise equal to 1)

Re =7432.75

jf = Pressure factor = 0.0049 ........ from figure 12.24 (Coulson volume 6)

By putting all values in equation 12.20 for pressure drop it comes out to

∆P = NP(8jf ( )( )-m +2.5)


2
∆P = 413.55 N/m
= 4.13kPa(Sufficient)

3. Shell Side Pressure Drop:

∆P = NP(8jf ( )( )( )-0.14
for less viscous fluids, correction factor is 1.
Shell side Reynolds no = 2142.16

Jh= 0.06 at calculated Reynolds no. of shell side

putting all values in equation ∆P = 4.2 Pa

You might also like