82560/82570

2/2-way diaphragm valves

>> Port size: DN 10,


1/4” ... 1/2”
(ISO G/NPT)
>> Suitable for vacuum
>> Compact solenoid with
integrated core tube
>> Valve operates without
differential pressure
>> International approvals

Technical features
Medium: Flow direction: Fluid temperature: Material:
Slightly aggressive gases Determined –10° ... +90°C (+14° ... +194°F) Body: Stainless steel (1.4408),
and liquids Port size: Ambient temperature: PA66
Switching function: G1/4, G3/8, G1/2, 1/4 NPT, –10° ... +50°C (+14° ... +122°F) Seat seal: NBR
Normally closed 3/8 NPT, 1/2 NPT Internal parts: Stainless steel,
Operation: Operating pressure: PVDF, Sandvik 1802
Solenoid actuated, 0 … 10 bar (0 ... 145 psi)
with forced lifting For contaminated fluids insertion of
Mounting position: a strainer is recommended.
Optional, preferably solenoid
vertical on top

Technical data – standard models


Symbol Port size Orifice Valve length Flow kv value *1) Operating Weight Model Model
(mm) (mm) (m3/h) pressure *2) (kg) Solenoid in V d.c. Solenoid in V a.c.
(bar) (psi)
G1/4 10 44 1,5 0 ... 10 0 ... 145 0,5 8256000.8001.xxxxx 8256000.8004.xxxxx
1/4 NPT 10 44 1,5 0 ... 10 0 ... 145 0,5 8257000.8001.xxxxx 8257000.8004.xxxxx
A
G3/8 10 44 1,7 0 ... 10 0 ... 145 0,5 8256100.8001.xxxxx 8256100.8004.xxxxx
3/8 NPT 10 44 1,7 0 ... 10 0 ... 145 0,5 8257100.8001.xxxxx 8257100.8004.xxxxx
P
G1/2 10 60 1,7 0 ... 10 0 ... 145 0,6 8256200.8001.xxxxx 8256200.8004.xxxxx
1/2 NPT 10 60 1,7 0 ... 10 0 ... 145 0,6 8257200.8001.xxxxx 8257200.8004.xxxxx
xxxxx Please insert voltage and frequency codes
*1) Cv-value (US) ≈ kv value x 1,2
*2) For gases and liquid fluids up to 25 mm2/s (cSt)

[email protected]
www.basesistemas.com
976 587 019
Our policy is one of continued research and development. We therefore reserve the right to amend, 10/19
without notice, the specifications given in this document. (2014 - 5737o) © 2015 Buschjost GmbH en 5.8.106.01
82560/82570
2/2-way diaphragm valves

Option selector 825˙˙˙˙.800˙.˙˙˙˙˙


Thread form Substitute Frequency Substitute
ISO G 6 See table frequency codes xx
NPT 7 Voltage Substitute
Port size Substitute See Voltage codes xxx
1/4 0 Solenoid options Substitute
3/8 1 Solenoid in V d.c. 1
1/2 2 Solenoid in V a.c. 4
Valve options Substitute with rectifier plug

Seat seal FPM, 03


for fuel and oil,
Fluid temperature –5 ... +110°C
(+23 ... +230°F)
Seat seal EPDM, 14
for hot water,
Fluid temperature +110°C
Degreased version, 18
Seat seal FPM,
Fluid temperature –5 ... +110°C
(+23 ... +230°F),
with solenoid 8041:
Fluid temperature –5 ... +80°C
(+23 ... +176°F)
Operating pressure 22
0 ... 20 bar (0 ... 290 psi),
only for NBR and a.c. solenoid,
only ATEX category 3 possible
Seat seal HNBR, 51
for hot water and steam,
Operating pressure 0 ... 6 bar
(0 ... 87 psi),
Fluid temperature 0 ... +150°C
(32 ... +302°F)
Solenoid vertical underneath:
up to max. +60 °C ambient
temperature permitted

Standard solenoid systems Electrical details for all solenoid systems


Voltage and Frequency Solenoid 8001 / 8004 Design DIN VDE 0580
Code Code Voltage Frequency Power consumption Voltage range ±10%
Voltage Frequency Inrush Holding Duty cycle 100% ED
024 00 24 V d.c. - 12 W 12 W Protection class EN 60529 IP65
024 49 24 V a.c. *3) 40 … 60 Hz 13 VA 13 VA Socket Form A acc. to DIN EN 175301-803 (included)
110 49 110 V a.c. *3) 40 … 60 Hz 13 VA 13 VA According to DIN VDE 0580 at a solenoid temperature of +20°C.
120 49 120 V a.c. *3) 40 … 60 Hz 13 VA 13 VA At operating state temperature the input power of a coil decreases by up to
ca. 30% due to physical reasons.
230 49 230 V a.c. *3) 40 … 60 Hz 13 VA 13 VA

*3) A.c. only with rectifier plug


Further versions on request! Additional solenoid systems for hazardous areas
ATEX ATEX IP protec- Solenoid Standard
category protection class tion class voltages
II 2G Ex eb mb IIC T3 Gb IP66 6200 24 V d.c., 110 V a.c.,
II 2D Ex mb tb IIIB T150°C Db 230 V a.c.
Attention!
The conditions imposed on the Ex approvals lead to reduction of the permissible
standard temperature ranges in the cases of explosion protected solenoids.

[email protected]
www.basesistemas.com
976 587 019
Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.8.106.02 without notice, the specifications given in this document. (2014 - 5737o) © 2015 Buschjost GmbH 10/19