Technical Bulletin: Light Gauge Framing Section Properties
Technical Bulletin: Light Gauge Framing Section Properties
Nicholasville, KY 40356
Office: (859) 887-4406
Toll Free: (800) 877-8709
www.abcmetalroofing.com
TECHNICAL BULLETIN
LIGHT GAUGE FRAMING SECTION PROPERTIES
¹⁄₂” Sub-Girt
1 ¹⁄₂”
¹⁄₂”
4 ³⁄₄” 1⁵⁄₈”
SECTION PROPERTIES
TOP IN COMPRESSION BOTTOM IN COMPRESSION
NOM.
THICK WT. Fy Ix Sx Fb Ix Sx Fb
GAUGE (IN.) (PLF) (KSI) (in.4) (in.3) (KSI) (in.4) (in.3) (KSI)
1” Sub-Girt
1⁵⁄₈”
1”
4 ³⁄₄”
SECTION PROPERTIES
TOP IN COMPRESSION BOTTOM IN COMPRESSION
NOM.
THICK WT. Fy Ix Sx Fb Ix Sx Fb
GAUGE (IN.) (PLF) (KSI) (in.4) (in.3) (KSI) (in.4) (in.3) (KSI)
.049 Nom. Thk. Allow Int. Bearing @ 3” = 1.488 K/Ft. Allow End Bearing @ 2” = 0.873 K/Ft.
Notes: 1. Section Properties and allowable stresses are calculated in accordance with the 1980 AISI specification for light gauge structural members.
2. Steel minimum yield strength is 33 KSI conforming to ASTM A446, Grade A.
3. Allowable loads for wind have been increased by 33%. Panel weight has not been deducted. Minimum bearing length must be checked.
4. Above live loads are limited by stress and meet or exceed deflection ratio of L/180 of span.
9-02/5M
Hat Section
1 ¹¹⁄₁₆”
1 ¹⁄₂”
3”
SECTION PROPERTIES
TOP IN COMPRESSION BOTTOM IN COMPRESSION
NOM.
THICK WT. Fy Ix Sx Fb Ix Sx Fb
GAUGE (IN.) (PLF) (KSI) (in.4) (in.3) (KSI) (in.4) (in.3) (KSI)
Channel Section
1 ¹⁄₂”
1 ⁵⁄₈”
SECTION PROPERTIES
TOP IN COMPRESSION BOTTOM IN COMPRESSION
NOM.
THICK WT. Fy Ix Sx Fb Ix Sx Fb
GAUGE (IN.) (PLF) (KSI) (in.4) (in.3) (KSI) (in.4) (in.3) (KSI)
.049 Nom. Thk. Allow Int. Bearing @ 3” = 1.896 K/Ft. Allow End Bearing @ 2” = 1.107 K/Ft.
Notes: 1. Section Properties and allowable stresses are calculated in accordance with the 1980 AISI specification for light gauge structural members.
2. Steel minimum yield strength is 33 KSI conforming to ASTM A446, Grade A.
3. Allowable loads for wind have been increased by 33%. Panel weight has not been deducted. Minimum bearing length must be checked.
4. Above live loads are limited by stress and meet or exceed deflection ratio of L/180 of span.
9-02/5M