Chapter One 1.1 Background
Chapter One 1.1 Background
Chapter One 1.1 Background
INTRODUCTION
1.1 Background
In the modern age, we are trying to communicate with the outside of the world within a very short
duration as much as possible. In such manner, we are always not only to deal with the persons to fulfill
our correspondences but also to control the electrical and electronic machines, appliances, equipment’s
etc. Nowadays, the humidity control alarm system is widely used especially in warm countries. Usually
the conventional humidity is always keep cooling the room depending on the fixed humidity setting
and is not automatically adjusted for the comfort of the users. In the central humidity control field,
excellent real-time, high reliability, and good intelligence are proposed by many researchers. The
traditional PID algorithm is, in fact, still playing a main role in the control process. The humidity
control alarm system has becoming a field to be researched to improve the user convenience by
applying intelligent system such as Adaptive Fuzzy controller. to meet our daily requirements that
supports for comforts. The existing control system can be done manually by supplying the proper
manpower which becomes time & cost ineffective, disgusting and unsuitable as well. So the necessity
of automatic controlling is important.
Now a day's every system is automated in order to face new challenges. In the present days Automated
systems have less manual operations, flexibility, reliability and accurate. Due to this demand every
field prefers automated control systems. Especially in the field of electronics automated systems are
giving good performance.
The most existing automatic humidity control alarm systems are lagging to get precise and smooth
variation of output, and proper hysteresis. Otherwise, some are used to behave manually which is much
more hazardous. All of the alarm control systems, those are commercially available, are mostly
integrated to the high costly and sophisticated appliances and equipment. That deprives the people to
use this type of alarm control systems to their designs and daily necessary devices and appliances.
LED are simple way of circulating the humidity to maintain a humidity and comfortable humidity.
They in a wide range of different styles and sizes to suit your needs. Such as Speaker, LED. While the
enhanced Humidity control alarm system is being designed, the consideration of the type of control
alarm system must be included in a modeling design. In particular the controller must be able to avoid
the inefficiency of having the room operate all the time. Several control alarm system options were
considered at presence sensing circuit, which would turn the humidity control alarm system off when
people are not in the room with the humidity control alarm system and a humidity sensor input, which
would change the humidity operation depending on room humidity [1]. Based on the observation of
the using the present conventional humidity application, it always working all the time without a
systematic control. Therefore, the control of the humidity control alarm system is adjusted through a
feedback control system to monitor and maintain a constant humidity based on the data input from the
sensor.
Our main objective is to design an independent control alarm system which responses on the ambience
conditions. The proposed system is more reliable, easy to handle, cost effective that overcome the
drawbacks of existing systems. This alarm system provides the variation in output corresponding to
the change of surrounding humidity. It is more flexible, compatible and adjustable to any electrical
and electronic devices.
1|Page
1.2 Problem Statement
The existing automatic humidity controlling alarm system in market nowadays, is too complex
in term of its design and structure. Since the system is not tool complex, it needs regular
preventive maintenance to be carried out to make sure the system operates well. Meanwhile,
when the maintenance is being done to the existing system, it could raise the cost of using the
system. Therefore, the project is designed with a low cost and all level users can have one for
a safety purpose.
1.3 Objectives
To develop the production of company and low cost simple automatic humidity control alarm
system.
To achieve the company goal.
To help the operators.
Introducing a technology with nearby available resources.
Make our country by making the system affordable and accessible at individual level.
2|Page
CHAPTER TWO
METHODOLOGY
2.1Block Diagram
The block diagram of simple automatic humidity control alarm system:
MICRO LED
HUMIDTY CONTRO
POWER
SENSOR LLER
SPEAKER
SUPPLY
OPERATIONAL
AMPLIFIER
PIC16F877A perfectly fits many uses, from automotive industries and controlling home appliances to
industrial instruments, remote sensors, electrical door locks and safety devices. It is also ideal for smart
3|Page
cards as well as for battery supplied devices because of its low consumption. EEPROM memory makes
it easier to apply microcontrollers to devices where permanent storage of various parameters is needed
(codes for transmitters, motor speed, receiver frequencies, etc.). Low cost, low consumption, easy
handling and flexibility make PIC16F877A applicable even in areas where microcontrollers had not
previously been considered (example: timer functions, interface replacement in larger systems,
coprocessor applications, etc.). In System Programmability of this chip (along with using only two
pins in data transfer) makes possible the flexibility of a product, after assembling and testing have
been completed. This capability can be used to create assembly line production, to store calibration
data available only after final testing, or it can be used to improve programs on finished products.
2.3.2 Potentiometer
A potentiometer (pot) is very simple and cheap form of transducers and widely used. It converts
any number in measurement into a voltage.
potentiometers for the measurements of humidity and take numerous forms dependent on
intended application. The simplest and cheapest form is a single length of wire along which a slider
or other form of moving device contacts the wire. The humidity position of the slider determines
the effective number of the conductor. Hence a change in electrical resistance or voltage drop is
related to the measurement number of the slider.
CHAPTER THREE
CIRCUIT DIAGRAM DISCRIPTION
5|Page
3.1 Circuit Diagram
Humidity Sensor is the heart of this circuit. It supplies voltage to the circuit by converting the Humidity
it sensed into an electrical signal. And this generated voltage is given to the operational amplifiers.
These operational amplifiers are inverting and non-inverting amplifiers. The circuit operates between
40 and 60 %. The voltage generated by the sensor is given to the Op amp and the Op amp compares
between the voltage generated by the sensor and the offset voltage connected to the other terminal of
the Op amp.
When the Humidity is restored to where it is designed to be i.e. between 40 and 60 % the output starts
to decrease its speed and stops because it reached at Humidity Point which is pleasant to function in.
6|Page
the highly advanced micro C Code Editor and we use some of the library functions in micro C
compiler. The micro C libraries are used to speed up the development: data acquisition, memory,
displays and conversions function.
Start
Literature review
Material required
Simulation
NO
Hardware implementation
End
YES
7|Page
3.4.1 Hardware implementation
The hardware part of the work involves the circuitry design and implementation of real components
on bread board.
CHAPTER FOUR
RESULT AND DISCUSSION
8|Page
Fig 4.2 when humidity > 40 and < 60.
9|Page
CHAPTER FIVE
CONCLUSION, BUDGET AND RECOMMENDATION
5.1 Conclusion
The project’s main concern is developing system which can minimize the existing problems of the
company and developing such a system can minimize cost and easy use. The project is successful in
developing the prototypes proteus circuit simulation software. After rigorously working on the detail
analysis, results and discussion the following conclusion are drawn out:
The project presents successful means of controlling humidity controlling by using alarm
system automatically.
The project will have a capacity of solving multi socioeconomic problems witnessed in
society.
Finally, the project will have a promising technology transform for the coming works with
related and advanced transformation of technology.
5.2 Budget
This project used some material and we buy from electronics shop but we have not more many for
by those material so we estimated the value.
5.3 Recommendation
This project has already finalized, because of a great passion and devotion of the group members, in
manner expected to be accomplished on our premise. However, had it been some of the following
recommendation considered it will be more appealing to effectively use on our daily base where such
system is crucial and even can be marketed.
We recommend for future extent we recommend to develop a system that reject a false signal.
We recommend that it is more reliable to use microcontroller.
Reference
1. http://www.howstuffswork.com
2. http://www.EEEE.com
3. http://www.embedtronics.com
10 | P a g e