TCPT1200: Vishay Telefunken
TCPT1200: Vishay Telefunken
Vishay Telefunken
Applications
D Accurate position sensor for encoder,
D Detection for motion direction,
D Suitable for computer mouse and track-balls 14848
Features
D Gap 2 mm
A Coll
D Package height: 4 mm
D Parts shipped taped and reeled 2000 pcs/ reel
D Soldering method according to
CECC00802 table 1, class B or C Cath E
D Surface Mountable Technology (SMD) 13895
Order Instruction
Ordering Code Resolution (mm) / Aperture (mm) Remarks
TCPT1200 0.24 / 0.3
Output (Detector)
Parameter Test Conditions Symbol Value Unit
Collector emitter voltage VCEO 70 V
Emitter collector voltage VECO 7 V
Collector current IC 20 mA
Power dissipation Tamb ≤ 25°C PV 75 mW
Coupler
Parameter Test Conditions Symbol Value Unit
Total power dissipation Tamb ≤ 25°C Ptot 150 mW
Ambient temperature range Tamb –40 to +85 °C
Storage temperature range Tstg –40 to +100 °C
Soldering temperature t≤5s Tsd 230 °C
Output (Detector)
Parameter Test Conditions Symbol Min. Typ. Max. Unit
Collector emitter voltage IC = 1 mA VCEO 70 V
Emitter collector voltage IE = 100 mA VECO 7 V
Collector emitter cut-off VCE = 25 V, IF = 0, E = 0 ICEO 10 100 nA
current
Coupler
Parameter Test Conditions Symbol Min. Typ. Max. Unit
Collector current VCE = 5 V, IF = 15 mA IC 300 500 mA
Collector emitter IF = 15 mA, IC = 0.05 mA VCEsat 0.4 V
saturation voltage
200
Ptot – Total Power Dissipation ( mW )
IF = 15 mA + VC = 5 V
Sensor
150
100
74HCT14
50
Emitter / Detector
10 kW VE UQ
0
0 25 50 75 100 GND GND 13887
13664 Tamb – Ambient Temperature ( °C )
VF – Forward Voltage ( V )
I F – Forward Current ( mA )
100.0
1.1
10.0
1.0
1.0
0.9
0.1 0.8
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 –40 –20 0 20 40 60 80 100
13660 VF – Forward Voltage ( V ) 13661 Tamb – Ambient Temperature ( °C )
Figure 3. Forward Current vs. Forward Voltage Figure 6. Forward Voltage vs. Ambient Temperature
VCEsat – Collector Emitter Saturation Voltage ( V )
0.180 1.0
IF=15mA
0.160 0.9 VCE=5V
IC=50mA
0.8
IC – Collector Current ( mA )
0.140
0.7 IF=15mA
0.120
0.6
0.100
0.5
0.080
0.4
0.060
0.3
0.040 IF=5mA
0.2
0.020 0.1
0 0
–40 –20 0 20 40 60 80 100 –40 –20 0 20 40 60 80 100
13662 Tamb – Ambient Temperature ( °C ) 13663 Tamb – Ambient Temperature ( °C )
Figure 4. Collector Emitter Saturation Voltage vs. Figure 7. Collector Current vs. Ambient Temperature
Ambient Temperature
10.000 10000
VCE=5V VCE=10V
IF=0
IC – Collector Current ( mA )
1.000 1000
with open Base ( nA )
0.100 100
0.010 10
0.001 1
0.1 1.0 10.0 100.0 0 10 20 30 40 50 60 70 80 90 100
13665 IF – Forward Current ( mA ) 96 11875 Tamb – Ambient Temperature ( °C )
Figure 5. Collector Current vs. Forward Current Figure 8. Collector Dark Current vs. Ambient Temperature
1.25
s
I Crel – Relative Collector Current
1.00
0.75
0.50
0.25
0
–1.5 –1.0 –0.5 0.0 0.5 1.0 1.5
13658 s – Displacement ( mm )
Packing
Dampproof packing
Products will be packed in anti-humidity aluminium bags to prevent the products from moisture absorption
during transportation and storage. Each bag contains a desiccant with moisture indicators. In the event bags
absorb moisture, the indicators change their color from blue to pink.
Recommended method of storage
Dry box storage is recommended to prevent the parts from moisture absorption. The following conditions
should be preserved if dry boxes are not available.
Storage temperature: 10 to 30°C Storage humidity: 60% RH max
In case of moisture absorption the device will recover to the former condition by drying under the following
recommended conditions:
Taped version: 60°C/ 48 h Untaped version: 60°C/ 48 h
Aluminium bag
Label
Reel
14940
12899
13722
13721
1. Meet all present and future national and international statutory requirements.
2. Regularly and continuously improve the performance of our products, processes, distribution and operating
systems with respect to their impact on the health and safety of our employees and the public, as well as
their impact on the environment.
It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as
ozone depleting substances ( ODSs ).
The Montreal Protocol ( 1987 ) and its London Amendments ( 1990 ) intend to severely restrict the use of ODSs and
forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban
on these substances.
Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of
ODSs listed in the following documents.
1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively
2 . Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental
Protection Agency ( EPA ) in the USA
3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C ( transitional substances ) respectively.
Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting
substances and do not contain such substances.
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications. All operating parameters must be validated for each customer application
by the customer. Should the buyer use Vishay Telefunken products for any unintended or unauthorized application, the
buyer shall indemnify Vishay Telefunken against all claims, costs, damages, and expenses, arising out of, directly or
indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use.