Micropile Design Report
Micropile Design Report
MICROPILE DESIGN
Introduction
Besides its high carrying capacity, less site constraint problems and self sustained
operation due to it light and compact drilling rigs and other ancillary
equipments. The sized of pile is vary from 100mm to 350mm with the capacity of
150kN to 2000kN respectively.
ii. Drill to hard layer, determine the rock founding level and drill to required
socket length
The independent tester was engaged by the Main Contractor and both BH7 and
BH9 were carried out by Advantage Geotest Services Sdn. Bhd after the working
platform ready at Reduced Level, RL 9.34m
The rock founding level is relatively 2.6 to 2.7m from the working platform. The
shallow rock layer had narrowed the selective of type of pile. Shallow follow (pad
Footing) will need to deep excavation to 3m depth. Non displacement pile such as
spun pile and R.C pile will not gain friction along the pile due to short pile with
soft layer silty Clay with SPT N value varies from 3 to 4.
Limestone was found after the soil layer, weather limestone with high Total Core
Recovery, TCR% which 100% for BH7 and BH9. The Rock Quality Designation,
QRD% values are varies which high at the top and gradually reduces to deeper
depth. Which the upper part of rock is high weathered rock and become moderate
strong after certain depth. Besides a cavity was found at BH 9 depth 4.04 to
4.42m which
ROCK QUALITY DESCRIPTION BASED ON RQD.
25-50 % Poor
50-75 % Fair
75-90 % Good
90-100 % Excellent
PROPOSED CONSTRUCTION AND COMPLETION OF THE PROPOSED KLINIK
KESIHATAN (JENIS 3) DENGAN KUARTES AT LOT 608, BLOCK 6, 17TH MILE,
SIBURAN KUCHING
Ultimate bond stress at the grout / rock is dependent on strength of grout , rock
and soil strength, quality of contact interface resulting from drilling, cleaning
and grouting operation.
Ultimate skin resistance is taken as 0.1 quc, using safety factor of 2, allowable
skin resistance is taken as 0.05quc however, value not exceeding 0.02 quc is
adopted in our design
minimum unconfine
Rock fsa, allowable rock friction fba,Allowable base rock compressive
resistance ( KN/m2) resistance ( KN/m2) = 0.2
=0.02quc quc strength(KN/m2), quc
type
1 Highly fractured and weak 500 5000 25000
limistone adopt 400 adopt 4000
type
2 Fractured and 800 8000 40000
moderately strong
limestone adopt 500 adopt 5000
type
3 Fractured and 1000 10000 50000
moderately strong
limestone adopt 750 adopt 6000
Therefore both structural and geotechnical design of the pile capacity of 500kN
with 6m > 4.85m required socket length for the highly weathered limestone
formation by assuming skin friction of 300N/mm.sq is SUFFICIENT