0% found this document useful (0 votes)
38 views1 page

Spirometri

This document contains the results of a spirometry test performed on Abdul Malik, a 17-year-old male patient. The test results show moderate restriction in Abdul's lung function compared to predicted values, with forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) below the predicted ranges. A post-bronchodilator test did not significantly improve the values, indicating the restriction is not reversible. The unconfirmed report concludes that Abdul has moderate lung restriction that is not reversible, and he smokes 11-20 cigarettes per day.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views1 page

Spirometri

This document contains the results of a spirometry test performed on Abdul Malik, a 17-year-old male patient. The test results show moderate restriction in Abdul's lung function compared to predicted values, with forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) below the predicted ranges. A post-bronchodilator test did not significantly improve the values, indicating the restriction is not reversible. The unconfirmed report concludes that Abdul has moderate lung restriction that is not reversible, and he smokes 11-20 cigarettes per day.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

custo med GmbH Abdul Malik

Leibnizstr. 7 Pat. ID Gender Male


85521 Ottobrunn Date of birth 16.01.2001 Height 166 cm
Tel. +49 89 71098-00 Age 17 Weight 56.0 kg
Fax: +49 89 71098-10
e-Mail: [email protected] Spirometry
Web: http://www.customed.de Evaluation 03.01.2019 11:40 o’clock

Summary
Predicted Reference: 11:40 Post Test: 11:40
Zapletal Percent Predicted Percent Predicted Percent Ref.
IVC l 3.93 2.08 53 % 2.24 57 % 108 %
FVC l 3.93 2.45 62 % 1.81 46 % 74 %
FEV1 l 3.26 2.45 75 % 1.81 55 % 74 %
TV l 0.55 0.53 96 % 0.83 150 % 156 %
FEV1%VC % 84 100 119 % 81 96 % 81 %
PEF l/s 6.74 5.72 85 % 5.55 82 % 97 %
MEF25%FVC l/s 2.13 3.12 146 % 2.78 130 % 89 %
MEF50%FVC l/s 4.15 4.45 107 % 5.26 127 % 118 %
MEF75%FVC l/s 5.83 5.07 87 % 2.62 45 % 52 %

Spirometry measurement
Flow l/s
6 Reference
Post Test
5

-1

-2

1 2 3 4 5 6 7 8 9 10 Volume in l
Predicted
Reference
Post Test

Volume in l
8 Reference
6 Post Test

1 2 3 4 5 6 7 8 9 10 Time sec

Unconfirmed report Smoker11-20 cigarettes per day


Moderate Restriction, not reversible.

custo vit m Environment data: 20 °C / 1013.0 hPa / 50 % / 0 m 03.01.2019


3.8.8 Build 6525 LC00000000 Device: spiro mobilewithout bacterial filter Page 1/1