0% found this document useful (0 votes)
166 views14 pages

03 - Roof - 4 Loading Data

This document provides the geometrical design data and design loads for the sky light atrium 4 of the Tata Memorial Centre project in Visakhapatnam, India. It includes the atrium dimensions, roof slope, spacing of purlins, dead loads from the roofing sheet, live loads, and wind loads calculated according to Indian design standards. Wind pressure coefficients are also provided for different roof surfaces and wind directions.

Uploaded by

Mayank Agrawal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views14 pages

03 - Roof - 4 Loading Data

This document provides the geometrical design data and design loads for the sky light atrium 4 of the Tata Memorial Centre project in Visakhapatnam, India. It includes the atrium dimensions, roof slope, spacing of purlins, dead loads from the roofing sheet, live loads, and wind loads calculated according to Indian design standards. Wind pressure coefficients are also provided for different roof surfaces and wind directions.

Uploaded by

Mayank Agrawal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 14

Project : TATA MEMORIAL CENTRE

Aganampudi, Visakhapatnam

Project Consultants : CRN Architects, Chennai


Client : HINDUSTAN CONSTRUCTION COMPANY
Structural Consultants : Narnindi Consulting Engineers
Title : Design data for Sky Light -4

I ATRIUM - 4 GEOMETRICAL DESIGN DATA


Length of the Atrium = 8.55 M

Width of the Atrium = 7.20 M

F.D.L. To F.F.L. = 0.60 M


F.F.L. Level = 82.50 M
Terrace Level = 98.45 M

Eaves Height from F.D.L. = 16.55 M

Roof Slope = 17 Deg


Maximum Spacing of Purlins (North & South) = 1.20 M
Maximum Spacing of Purlins (East & West) = 1.154 M

II DESIGN LOADS
1 DEAD LOAD :

Roofing Sheet density as per Manufacturer's


= 1200.00 Kg/Cu.M
data sheet (Tuflite Top Seam)

Sheet thickness = 12.00 mm


Self weight of roofing sheet = 14.40 Kg/Sq.M

Design weight of roofing sheet including


= 20.00 Kg/Sq.M
accessories

= 0.20 Kn/Sq.M

Dead Load on North & South side Roofs = 0.240 Kn/M


Dead Load on East & West side Roofs = 0.231 Kn/M

IS:875- 2003 (Part 2) Table - 2, S.No


2 LIVE LOAD : = 0.75 Kn/Sq.M
Access not provided except for mainte

ii) Sloping roof with slope greater than 10


degrees For roof membrane sheets or purlins-
= 0.61 Kn/Sq.M
0.75 kN/mZ less 0.02 kN/m for every degree
increase in slope over 10 degrees

Live Load on North & South side Roofs = 0.732 Kn/M


Live Load on East & West side Roofs = 0.704 Kn/M
Design Data Ncoen Page 1
3 WIND LOAD : as per IS 875 Part-3, 2015

a Basic Wind Speed (Vb) = 50 m/sec

As per IS:875 -2015 - Basic wind speed Map of


= 180 KMPH
India

b Design Wind Speed (Vz) = Vb x K1 x K2 x K3 x K4

K1 = 1.08 As per IS:875 -2015, part 3 , Table 1, Sl.No. (iv)

As per IS:875 -2015, part 3 , Table 2, Terrain Cat


K2 = 1.0562
Height 16.55m

K3 = 1.0 As per IS:875 -2015, part 3 , Clause 6.3.3.1

K4 = 1.30 As per IS:875 -2015, part 3 , Clause 6.3.4, for Ho

Design Wind Speed (Vz) = 50 x 1.08 x 1.0562 x 1.00 x


= 74.15 m/Sec

c Wind Pressure Pz = 0.6 Vz2


= 3298.50997 N/Sq.m
= 3.30 Kn/Sq.m

d Design Wind Pressure Pd = Kd Ka Kc Pz

As per IS:875 -2015, part 3 , 7.2.1 Wind direction


Kd = 1.0
for the Cyclone affected regions

As per IS:875 -2015, part 3 , Table 4, Sl.No.3, Cla


Ka = 0.8
(b)

Kc = 0.9 As per IS:875 -2015, part 3 , Clause 7.3.3.13

Design Wind Pressure Pd 1.00 0.8 0.9 3.30 2.375 Kn/Sq.m

EXTERNAL PRESSURE CO-EFFICIENTS FOR ROOFS As per IS:875 -2015, part 3 , Table 6

Building
h/w = 2.299 3/2 £ h/w £ 6
& Roof

Wind flowing from West to east


EF (Wind ward) GH (Lee Ward)
Wind Perpendicular to Ridge 0 deg -0.77 -0.6
North
E G 7.2M (W
Design Data Ncoen Page 2
E G

8.55m
West
F H

South
10 Deg 20 Deg for 17 Deg
EF -0.7 -0.8
FOR 1 DEG -0.01 -0.77
GH -0.6 -0.6 -0.6
EG -0.8 -0.8 -0.8
FH -0.8 -0.8 -0.8

Hipped Slope M, N for 0 deg Incidence -0.8


-0.8

Hipped Slope M, N for 90 deg Incidence -0.77


0.6

Wind flowing from North to South

Building
h/w (h/l) = 1.936 3/2 £ h/w £ 6
& Roof

EF (Wind ward) GH (Lee Ward)


Wind Perpendicular to Ridge 0 deg -0.77 -0.6
North
E G 7.2M

West 8.55m (W)


F H

10 Deg 20 Deg for 17 Deg South


EF -0.7 -0.8
FOR 1 DEG -0.01 -0.77
GH -0.6 -0.6 -0.6
EG -0.8 -0.8 -0.8
FH -0.8 -0.8 -0.8

Hipped Slope M, N for 0 deg Incidence -0.8


-0.8

Design Data Ncoen Page 3


Hipped Slope M, N for 90 deg Incidence -0.77
-0.6
Internal pressure co-efficient as per Clause 7.3.2.2 ± 0.7

NET CO-EFFICIENTS FOR ROOF Wind flowing from West to east


Perpendicular to ridge with internal pressure
Wind Ward (West) = -0.77 - 0.7 = -1.47
Lee Ward (East) = -0.6 - 0.7 = -1.30

Perpendicular to ridge with internal suction


Wind Ward (West) = -0.77 - -0.7 = -0.07
Lee Ward (East) = -0.6 - -0.7 = 0.10

Parallel to ridge with internal pressure


Wind Ward (West) = -0.8 - 0.7 = -1.50
Lee Ward (East) = -0.8 - 0.7 = -1.50

Parallel to ridge with internal suction


Wind Ward (West) = -0.8 - -0.7 = -0.10
Lee Ward (East) = -0.8 - -0.7 = -0.10

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure
North = -0.8 - -0.7 = -0.1
South = -0.8 - -0.7 = -0.1

Perpendicular to ridge with internal Suction


North = -0.77 - 0.7 = -1.47
South = -0.6 - 0.7 = -1.3

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
North = -0.8 - -0.7 = -0.1
South = -0.8 - -0.7 = -0.10

Perpendicular to ridge with internal Suction


North = -0.77 - 0.7 = -1.47
South = -0.6 - 0.7 = -1.30

Design Data Ncoen Page 4


NET CO-EFFICIENTS FOR ROOF Wind flowing from North to South
Perpendicular to ridge with internal pressure
wind ward (North) = -0.77 - 0.7 = -1.47
Lee Ward (South) = -0.6 - 0.7 = -1.30

Perpendicular to ridge with internal suction


wind ward (North) = -0.77 - -0.7 = -0.07
Lee Ward (South) = -0.6 - -0.7 = 0.10

Parallel to ridge with internal pressure


wind ward (North) = -0.8 - 0.7 = -1.50
Lee Ward (South) = -0.8 - 0.7 = -1.50

Parallel to ridge with internal suction


wind ward (North) = -0.8 - -0.7 = -0.10
Lee Ward (South) = -0.8 - -0.7 = -0.10

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure
West = -0.8 - -0.7 = -0.10
East = -0.8 - -0.7 = -0.10

Perpendicular to ridge with internal Suction


West = -0.77 - 0.7 = -1.47
East = 0.6 - 0.7 = -0.10

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
West = -0.8 - -0.7 = -0.1
East = -0.8 - -0.7 = -0.10

Perpendicular to ridge with internal Suction


West = -0.77 - 0.7 = -1.47
East = 0.6 - 0.7 = -0.10
MAXIMUM PURLIN SPACINGS
FOR "N" & "S" = 1.200 M
FOR "E" & "W" = 1.154 M

Net Pressure Wind flowing from West to East

Perpendicular with Internal pressure Pd x Net co-efficient x spacing of purlin


wind ward (West) = -4.03 Kn/Rmt
Lee Ward (East) = -3.56 Kn/Rmt
Design Data Ncoen Page 5
Perpendicular with Internal Suction
Wind ward (West) = -0.19 Kn/Rmt
Lee Ward (East) = 0.27 Kn/Rmt

Parallel with Internal pressure


wind ward (West) = -4.11 Kn/Rmt
Lee Ward (East) = -4.11 Kn/Rmt

Parallel with Internal Suction


Wind ward (West) = -0.27 Kn/Rmt
Lee Ward (East) = -0.27 Kn/Rmt

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure 20% LESS
North = -0.28 Kn/Rmt -0.228 Kn/Rmt
South = -0.28 Kn/Rmt -0.228 Kn/Rmt

Perpendicular to ridge with internal Suction


North = -4.19 Kn/Rmt -3.351 Kn/Rmt
South = -0.28 Kn/Rmt -0.228 Kn/Rmt

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
North = -0.28 Kn/Rmt -0.228 Kn/Rmt
South = -0.28 Kn/Rmt -0.228 Kn/Rmt

Perpendicular to ridge with internal Suction


North = -4.19 Kn/Rmt -3.351 Kn/Rmt
South = -0.28 Kn/Rmt -0.228 Kn/Rmt

Net Pressure Wind flowing from North to South

Perpendicular with Internal pressure


wind ward (North) = -4.19 Kn/Rmt
Lee Ward (South) = -3.70 Kn/Rmt

Perpendicular with Internal Suction


wind ward (North) = -0.20 Kn/Rmt
Lee Ward (South) = 0.28 Kn/Rmt

Parallel with Internal pressure


wind ward (North) = -4.27 Kn/Rmt
Lee Ward (South) = -4.27 Kn/Rmt

Design Data Ncoen Page 6


Parallel with Internal Suction
wind ward (North) = -0.28 Kn/Rmt
Lee Ward (South) = -0.28 Kn/Rmt

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure 20% LESS
West = -0.27 Kn/Rmt -0.219 Kn/Rmt
East = -0.27 Kn/Rmt -0.219 Kn/Rmt

Perpendicular to ridge with internal Suction


West = -4.03 Kn/Rmt -3.223 Kn/Rmt
East = -3.56 Kn/Rmt -2.85 Kn/Rmt

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
West = -0.27 Kn/Rmt -0.219 Kn/Rmt
East = -0.27 Kn/Rmt -0.219 Kn/Rmt

Perpendicular to ridge with internal Suction


West = -4.03 Kn/Rmt -3.223 Kn/Rmt
East = -3.56 Kn/Rmt -2.85 Kn/Rmt

Design Data Ncoen Page 7


t 2) Table - 2, S.No. 1-(i) b -
ed except for maintenance

Design Data Ncoen Page 8


Table 1, Sl.No. (iv)

Table 2, Terrain Category - 2,

Clause 6.3.4, for Hospital Building

1.30

7.2.1 Wind directionality Factor


ns

Table 4, Sl.No.3, Clause 7.2.2.1

Building Height Ratio


& Roof Angle 17 Deg

North
7.2M (Width)
Design Data Ncoen Page 9
East

South 0 90
E -0.77 -0.8
F -0.77 -0.8
G -0.6 -0.8
H -0.6 -0.8

M,N WIND WARD -0.8 0 DEG


LEE WARD -0.8
Wind Ward
Lee Ward M,N WIND WARD -0.77 90 DEG

Wind Ward LEE WARD -0.6


Lee Ward

Building Height Ratio


& Roof Angle 17 Deg

North
7.2M

East

South 0 90
E -0.77 -0.8
F -0.77 -0.8
G -0.6 -0.8
H -0.6 -0.8
M,N WIND WARD -0.8 0 DEG
LEE WARD -0.8
Wind Ward
Lee Ward M,N WIND WARD -0.77 90 DEG

Design Data Ncoen Page 10


Wind Ward LEE WARD -0.6
Lee Ward

Design Data Ncoen Page 11


Resolving Forces

Gy Gx
-4.007 -0.421
-3.543 -0.372
Design Data Ncoen Page 12
-0.191 -0.020
0.273 0.029

-4.088 -0.430
-4.088 -0.430

-0.273 -0.029
-0.273 -0.029

-0.227 -0.024
-0.227 -0.024

-3.333 -0.350
-0.227 -0.024

-0.227 -0.024
-0.227 -0.024

-3.333 -0.350
-0.227 -0.024

Resolving Forces

Gy Gx
-4.166 -0.438
-3.685 -0.387

-0.198 -0.021
0.283 0.030

-4.251 -0.447
-4.251 -0.447

Design Data Ncoen Page 13


-0.283 -0.030
-0.283 -0.030

-0.218 -0.023
-0.218 -0.023

-3.205 -0.337
-2.835 -0.298

-0.218 -0.023
-0.218 -0.023

-3.205 -0.337
-2.835 -0.298

Design Data Ncoen Page 14