To Obtain Performance Characteristics For Variable Speed Centrifugal Pump Operating at Different Impeller Speeds
To Obtain Performance Characteristics For Variable Speed Centrifugal Pump Operating at Different Impeller Speeds
3 Motor Converts
electricity to
mechanical energy,
drive the
centrifugal pump
4 Discharge valve Control the flow of
water
1) Make sure the height of the water level inside the water tank is zero.
2) The pump discharge and suction valves were turned to fully open, and the motor
speed was set at zero.
3) The motor turned on and ready for testing.
4) Maximum pump speed, N1, was set to 50% (adjust the speed control).
5) The volume of flow indicator is noted and decides suitable increments in flow to give
adequate sample points about 15 points between zero and maximum flow).
6) Discharge valve closed, wait for the reading to be steady, and the reading was
collected.
7) The discharge valve is opened slightly, to give the first increment in volume flow.
When readings are steady, take the measurements.
8) Repeat step 7, the final measurements corresponding to the valve being fully open.
9) The experiment then was repeated at pump speed corresponding to speed control
position of 75% and 100%.