Dishwasher With Easy UI & Connectivity: Serkan DEMİR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

E8

Dishwasher with Easy UI &


Connectivity

Serkan DEMİR
ARÇELİK BMİ- January / 2018
Sensitivity: Public
E8 PROJECT

EASY UI

Accessing programs and functions easily with one touch.

CONNECTIVITY

Control your dishwasher by using your mobile device

Sensitivity: Public
AIM & GOAL

AIM

The aim of the project; to create an ergonomic top controlled control card
with a separate key for each program and function.

GOAL

To increase quality perception of the product,


To gain connectivity feature to product.

Sensitivity: Public
NEW COMPONENTS

New Panel – New Facia

Sensitivity: Public
NEW COMPONENTS

WeMod (Connectivity) Boards

Simple (Distinct) Model


This model is mounted inside the
panel (like display and button
board) and does not require
external antenna to communicate.

Integrated Model
This model is used in dishwasher
with metal door and mounted into
door with handle. It requires
external antenna equipped with
copper wire to communicate.

Purple part covers external


antenna and yellow part covers
WeMod board.
Sensitivity: Public
E8-User Interface
( Button Board )

1 : Soft On/Off button


2 : HomeWhiz Activation / Deactivation Button
3 : Program Selection Buttons (# of programs depends on the model) – Max 9 programs
4 : Function Selection Buttons (# of functions depends on the model) – Max 5 functions
5 : Settings Menu Button
6 : Delay Time Selection / Menu Navigation Buttons
7 : Selection / Confirmation Button
8 : Program Start / Pause / Cancel Button

E8P Display

Sensitivity: Public
E8-User Interface
( Display Board )

1 : 3 in 1 (tablet) icon 9 : Buzzer volume level setting menu icon


10: «No Water» indicator
2 : Liquid detergent icon
3 : Automatic door open icon 11: 7-segment display for program remaining time and delay time
12: Delay icon
4 : Self cleaning filter function icon
13: «Program End» information icon
5 : Ionizer (odour removal) function icon 14: «Salt» indicator
6 : Wi-Fi Settings icon 15: «Shiner» indicator
7 : Wi-Fi connection icon
8 : Water hardness setting menu icon

Sensitivity: Public
E8
Service Menu

Press buttons #1 & #5 together at the same time in order to enter service functions
mode. After waiting countdown from 3 to 1, service menu will display the first item
H:Ft.

Sensitivity: Public
E8
Service Menu
Automated short function test used in production
lines in the Dishwasher Plant

Operator supported function test used in production


lines in the Dishwasher Plant

Functional short program test used by service users

Eeprom reset
(returns dishwasher into default factory setting)

Displays electronic board software versions respectively


Πb: Main (mother) board / db: Display Board
bb: Button Board
Sensitivity: Public
SETTINGS MENU

As desribed in user manual this menu is designed for customer prefferences setings:
•When the dishwasher is in program selection mode; Press Menu Key (button #5 shown in figure)
about 3sec to enter the settings menu.
•Press [<-] and [->] keys to navigate in service menu and display current settings.
•Press [SELECT] key to change settings
•Press [MENU] key to exit from the menu.

Sensitivity: Public
Settings Menu – Self Cleaning Filter( if available )

Will be available in settings menu if the dishwasher has self cleaning filter feature;

0 : filter cleaning function will not work.


1 : filter will get cleaned after each washing programme automaticaly to have a
better washing performance.

Sensitivity: Public
Settings Menu – Tablet Feature Enabling ( if available )

Will be available in settings menu if the dishwasher has 3 in 1 (tablet) feature;

• 0 : 3 in 1 (tablet) feature is disabled


• 1 : 3 in 1 (tablet) feature is enabled

Sensitivity: Public
Settings Menu - Regeneration Level Adjustment

As described in user manual regeneration level need


to be set according to the water hardness.
•Navigate through -> and <- buttons
•Press [SELECT] key to change regeneration setting
•Press [MENU] key to exit from the menu.

Level 5: Make regeneration in every 9lt water usage


Level 4: Make regeneration in every 30lt water usage
Level 3: Make regeneration in every 52lt water usage
Level 2: Make regeneration in every 105lt water usage
Level 1: Do not make regeneration any time

Sensitivity: Public
Settings Menu - Shiner Dosage Level Adjusting

As described in user manual shiner


dosage level need to be set according to
the user preferences.

•Navigate through -> and <- buttons


•Press [SELECT] key to change shiner
dosage level setting
•Press [MENU] key to exit from the menu.

P: 0  Do not use shiner


P: 1  Use 1,5cc shiner
P: 2  Use 3cc shiner
P: 3  Use 4,5cc shiner
P: 4  Use 6cc shiner

Sensitivity: Public
Settings Menu – Inner / Top Illumuniation ( if available )

Will be available in settings menu if the dishwasher has inner / top illumination
feature;

L:0 internal / top light always off.


L:1 internal / top light will be on for 2min. after openning the door.

Sensitivity: Public
Settings Menu – Sound Level Setting

This setting is used to set buzzer


sound level

• S:0 sound is OFF


• S:1 low sound level
• S:2 high sound level

Sensitivity: Public
Settings Menu – Auto Door Opening ( if available )

Will be available in settings menu if the dishwasher has auto door opening feature;
• 0 : auto door opening feature will be closed.
• 1 : the door will be opened at the end of each program to have a better drying
performance.

Sensitivity: Public
Settings Menu – Connectivity Enable / Disable
( if available )

Will be available in settings menu if the dishwasher has connectivity feature;


• 0 : disable connectivity.
• 1 : enable connectivity to control your machine via your mobile device.

Connectivity : Wi-Fi / Bluetooth

Sensitivity: Public
Settings Menu – Ionizer (Odor Removal) Feature
( if available )

Will be available in settings menu if the dishwasher has ionizer (odour removal)
feature;
• 0 : ionizer (odour removal) feature will be closed.
• 1 : ionizer (odour removal) feature is enabled to defeat bad odour when dishwasher
is not working. In stand by mode, ionizer is activated for 6 minutes in every 1 hour.

Sensitivity: Public
Settings Menu
Liquid Detergent Dosage Level Adjustment
( if available )

As described in user manual liquid detergent dosage


level need to be set according to the user
preferences.
•Navigate through -> and <- buttons
•Press [SELECT] key to change liquid detergent dosage
level setting
•Press [MENU] key to exit from the menu.

Level 1: default program value – 10cc


Level 2: default program value – 5cc
Level 3: do not change amount of liquid detergent
defined by the program itself
Level 4: default program value + 5cc
Level 5: default program value + 10cc

Sensitivity: Public
ACCESS POINT MODE (SETUP FOR CONNECTIVITY)

Press buttons #1 & #2 at the same time while


dishwasher is in standby mode.
In display 7-segment, it will countdown from 3
to 1 and will switch to the Access point mode.

In Access mode, 7-segment displays simple


animation as seen on the right…
Open homewhiz wizard at your mobile device
and register the product.

Sensitivity: Public
ENABLING / DISABLING HOMEWHIZ FEATURE

Press buttons #2 to enable / disable homewhiz


mode.
Related button led will be illuminated / off

Simple animation will be flashed as seen on the


left.
Dishwasher can be controlled via mobile device
which has homewhiz application.

Sensitivity: Public
REMOVING DISHWASHER from the CLOUD

Press buttons #1 & #6 (left or right navigation


button) at the same time while dishwasher is in
standby mode.

In this mode, 7-segment displays simple


animation as seen on the right… (leds seem to
be rotated clockwise)

When animation ends, dishwasher will be


removed from the cloud system that it was
already registered.

Sensitivity: Public
ERROR CODES
Errors diagnosed during the dishwasher usage will be
displayed on screen;
•[E:01] and [E:02] will be displayed also in normal use.
•Other error codes will be displayed only in service mode.

E : 01 Overflow
E : 02 No Water Fault
E : 03 Heater Fault
E : 04 Turbidity Fault
E : 05 Multiway Valve Fault
E : 06 NTC Fault
E : 07 Water Inlet Valve Fault
E : 08 External Board Comm. Fault
E : 09 Display Board Comm. Fault
E : 10 Conducto Board Comm.Fault
E : 11 Conducto Probe Fault
E : 12 Conducto Short Circuit Fault
E : 13 Dry Run Fault
E : 14
E : 15 Water Counter Fault
E : 16 Drain Pump Blocked Fault
E : 17 ADD Position Fault
E : 18 Low Voltage Error
Sensitivity: Public
TROUBLESHOOTING- General

E8 Dishwashers are electronically controlled and some faulty conditions can


be detected by the electronics. These errors are detected not only in the
functional test program but also during the washing cycles. The previously
detected errors are kept in memory and shown in display.

When the test programs are started, error date in memory will be cleared
which enables to understand if the same fault occurs during the functional
test again. At the end of the test diagnossed errors date will also be cleared.

Sensitivity: Public
TROUBLESHOOTING- OverFlow [Er:1]

If the control system senses an overflow signal for 20 seconds from the overflow switch
the system enters a standby state for 2 minutes. During the standby time the drain
pump automatically runs. After the standby duration is completed if the control system
still senses an overflow signal the machine gives “Call service” error message. The
system stops responding to any user input except the ON/OFF button.
If there is no overflow signal after 2 minute standby time the machine continue to
work normally.

Possible reasons:
•Broken components or torned hoses
•Malfunction of drain pump
•Malfunction of flowmeter
•Malfunction of water inlet valve
•Cable harness errors
•Faulty electronics

Sensitivity: Public
TROUBLESHOOTING- No Water [E:02]

Incoming water to the machine is monitored via a water counter (flow meter)
system. Water counter generates electronic pulses. During the “Water Inlet” step
(for any program including functional test) if no pulses could be sensed by the
electronics, No Water condition occurs. At this condition the dishwasher will wait
until water signal is detected. If necessary water signal is detected the machine
will continue its normal operation.

Possible reasons:

a.Malfunction of water inlet valve


b.No water
c.Insufficient water pressure
d.Cable harness errors
e.Faulty electronics

Sensitivity: Public
TROUBLESHOOTING- Heater Fault [E:03]

The water temperature in the machine is measured by an NTC (negative temperature


coefficient). NTC is simply a resistance value dependent on temperature.
At the Heating step, if the temperature rise is less than 1 C within 3 minutes heating
fault occurs. When the fault detected software skips the heating step and continues
the program with the next step.

Possible reasons:

a. Malfunction of heater
b. Malfunction of NTC (constant NTC resistance)
c. Cable harness errors
e. Faulty electronics

Note: During the first 3 minutes of a heating step the water temperature is not
controlled. The control system waits so that the temperature inside the machine reaches
balance.

Sensitivity: Public
TROUBLESHOOTING- Turbidity Fault [E:04]

Turbidity sensor is the component that measures the amount of dirt in the
water. The machine uses this data for the steps of Auto Program (if
applicable). If the proper data from the turbidity sensor cannot be received,
Turbidity Sensor Error occurs. When the error occurs, the software
continues the program as heavy dirt level.

Possible reasons:
a.Malfunction of Turbidity Sensor
b.Cable harness errors
c.Faulty electronics

Sensitivity: Public
TROUBLESHOOTING
Diverter Valve Pos. Fault [E:05]

3Way / Multi Valve is the component that diverts the water flow between the
upper and lower trays independently. It is driven by the electronics and the
position of the valve is measured by a feedback signal. Diverter Valve Position
Error occurs if the proper position signal could not be received from the valve.
When the error occurs, the electronics drives the valve until proper position
signal is achieved.

Possible reasons:

a.Malfunction of water diverter way valve


b.Cable harness errors
c.Faulty electronics

Sensitivity: Public
TROUBLESHOOTING- NTC Fault [E:06]

At the Heating step, if NTC resistance is measured beyond the specified resistance
values or if the NTC resistance is measured as open/short circuit NTC fault occurs.
When the fault is detected software skips the heating step and continues the
program with the next step.

Possible reasons:

a.Malfunction of NTC
b.Cable harness errors
c.Faulty electronics

Sensitivity: Public
TROUBLESHOOTING- Water Inlet Valve Fault [E:07]

The electronics of the machine monitors water counter pulses at every step of
the washing program. If pulses are received from the counter at any step other
than Water-Inlet; Water Inlet Error occurs. When the fault is detected, software
drives the drain pump 1 minute then check the counter signal again.
- If the signal exists, that means the faulty condition does still continue. Then
drain pump is activated with 1 minute intervals (1 min ON, 1 min. OFF)
- Instead if the signal is stopped, then software continues with the selected
program.

Possible reasons:

a.Malfunction of water inlet valve (stuck as open)


b.Faulty electronics

Sensitivity: Public
TROUBLESHOOTING
External Board Communication Fault [E:08]

During machine working cycle, if communication between main electronic board and
external electronic board is lost; this fault is encountered.

Possible reasons:

a. Cable harness errors


b. Faulty socket installation
c. Faulty electronics
External electronic board
Main electronic board

Sensitivity: Public
TROUBLESHOOTING
Display Board Communication Fault [E:09]

During machine working cycle, if communication between main electronic board and
display electronic board is lost; this fault is encountered.

Possible reasons:

a. Cable harness errors


b. Faulty socket installation
c. Faulty electronics
External electronic board
Display electronic board

Sensitivity: Public
TROUBLESHOOTING
Conducto Board Communication Fault [E:10]

During machine working cycle, if communication between main electronic board and
conducto electronic board is lost; this fault is encountered.
(This fault is encountered only in machines with conducto feature)

Possible reasons:

a. Cable harness errors


b. Faulty socket installation
c. Faulty electronics
External electronic board
Conducto electronic board

Sensitivity: Public
TROUBLESHOOTING
Conducto Probe / Short Circuit Faults [E:11 / E:12]

These errors are encountered when conducto probe cable harness occurs or cable
sockets installed in wrong direction.

Possible reasons:

a. Cable harness errors


b. Faulty socket installation

Sensitivity: Public
TROUBLESHOOTING
Pressure Switch Fault [E:13]

Machines with pressure switch feature, in washing cycle, after water inlet is completed
the pressure switch is clicked. If it is not, pressure swtch fault is encountered.

At the water inlet part of the programme, after enough amount of water is taken
into the sump (apprx 2,5 liter); pressure switch is expected to be clicked.

Possible reasons:

a. Faulty pressure switch


b. Faulty water inlet counter
c. Faulty electronics

Sensitivity: Public
TROUBLESHOOTING
Water Counter Fault [E:15]

At washing cycle water inlet step, if water counter does not increase but the pressure
switch clicks; main board software encounters «water counter» fault.

Possible reasons:

a. Cable between main board and water counter may be broken


b. Cable sockets may not be properly installed.
c. Faulty water counter
d. Faulty pressure switch
e. Faulty electronics

Sensitivity: Public
TROUBLESHOOTING
Drain Pump Blocked Fault [E:16]

At drain (evacuation) step, pressure switch position is controlled by the mainboard


while 5 seconds left to finish step. If pressure switch still stays «clicked», «drain pump
blocked» fault is encountered.

Possible reasons:

a. Faulty drain pump.


b. Faulty pressure switch
c. Faulty electronics

Sensitivity: Public
TROUBLESHOOTING
Automatic Detergent Dosage Motor Positioning
Fault [E:17]
At liquid detergent dosing step, dosage motor tries to find right position.
If position can not be found in specified time interval, position fault counter is
increased. After 2 unsuccessfull try, electronic board gives [E:17] error.

Possible reasons:

a. Faulty dosage motor


b. Misconnected or unconnected motor cable
c. Faulty electronics

Sensitivity: Public