Dishwasher With Easy UI & Connectivity: Serkan DEMİR
Dishwasher With Easy UI & Connectivity: Serkan DEMİR
Dishwasher With Easy UI & Connectivity: Serkan DEMİR
Serkan DEMİR
ARÇELİK BMİ- January / 2018
Sensitivity: Public
E8 PROJECT
EASY UI
CONNECTIVITY
Sensitivity: Public
AIM & GOAL
AIM
The aim of the project; to create an ergonomic top controlled control card
with a separate key for each program and function.
GOAL
Sensitivity: Public
NEW COMPONENTS
Sensitivity: Public
NEW COMPONENTS
Integrated Model
This model is used in dishwasher
with metal door and mounted into
door with handle. It requires
external antenna equipped with
copper wire to communicate.
E8P Display
Sensitivity: Public
E8-User Interface
( Display Board )
Sensitivity: Public
E8
Service Menu
Press buttons #1 & #5 together at the same time in order to enter service functions
mode. After waiting countdown from 3 to 1, service menu will display the first item
H:Ft.
Sensitivity: Public
E8
Service Menu
Automated short function test used in production
lines in the Dishwasher Plant
Eeprom reset
(returns dishwasher into default factory setting)
As desribed in user manual this menu is designed for customer prefferences setings:
•When the dishwasher is in program selection mode; Press Menu Key (button #5 shown in figure)
about 3sec to enter the settings menu.
•Press [<-] and [->] keys to navigate in service menu and display current settings.
•Press [SELECT] key to change settings
•Press [MENU] key to exit from the menu.
Sensitivity: Public
Settings Menu – Self Cleaning Filter( if available )
Will be available in settings menu if the dishwasher has self cleaning filter feature;
Sensitivity: Public
Settings Menu – Tablet Feature Enabling ( if available )
Sensitivity: Public
Settings Menu - Regeneration Level Adjustment
Sensitivity: Public
Settings Menu - Shiner Dosage Level Adjusting
Sensitivity: Public
Settings Menu – Inner / Top Illumuniation ( if available )
Will be available in settings menu if the dishwasher has inner / top illumination
feature;
Sensitivity: Public
Settings Menu – Sound Level Setting
Sensitivity: Public
Settings Menu – Auto Door Opening ( if available )
Will be available in settings menu if the dishwasher has auto door opening feature;
• 0 : auto door opening feature will be closed.
• 1 : the door will be opened at the end of each program to have a better drying
performance.
Sensitivity: Public
Settings Menu – Connectivity Enable / Disable
( if available )
Sensitivity: Public
Settings Menu – Ionizer (Odor Removal) Feature
( if available )
Will be available in settings menu if the dishwasher has ionizer (odour removal)
feature;
• 0 : ionizer (odour removal) feature will be closed.
• 1 : ionizer (odour removal) feature is enabled to defeat bad odour when dishwasher
is not working. In stand by mode, ionizer is activated for 6 minutes in every 1 hour.
Sensitivity: Public
Settings Menu
Liquid Detergent Dosage Level Adjustment
( if available )
Sensitivity: Public
ACCESS POINT MODE (SETUP FOR CONNECTIVITY)
Sensitivity: Public
ENABLING / DISABLING HOMEWHIZ FEATURE
Sensitivity: Public
REMOVING DISHWASHER from the CLOUD
Sensitivity: Public
ERROR CODES
Errors diagnosed during the dishwasher usage will be
displayed on screen;
•[E:01] and [E:02] will be displayed also in normal use.
•Other error codes will be displayed only in service mode.
E : 01 Overflow
E : 02 No Water Fault
E : 03 Heater Fault
E : 04 Turbidity Fault
E : 05 Multiway Valve Fault
E : 06 NTC Fault
E : 07 Water Inlet Valve Fault
E : 08 External Board Comm. Fault
E : 09 Display Board Comm. Fault
E : 10 Conducto Board Comm.Fault
E : 11 Conducto Probe Fault
E : 12 Conducto Short Circuit Fault
E : 13 Dry Run Fault
E : 14
E : 15 Water Counter Fault
E : 16 Drain Pump Blocked Fault
E : 17 ADD Position Fault
E : 18 Low Voltage Error
Sensitivity: Public
TROUBLESHOOTING- General
When the test programs are started, error date in memory will be cleared
which enables to understand if the same fault occurs during the functional
test again. At the end of the test diagnossed errors date will also be cleared.
Sensitivity: Public
TROUBLESHOOTING- OverFlow [Er:1]
If the control system senses an overflow signal for 20 seconds from the overflow switch
the system enters a standby state for 2 minutes. During the standby time the drain
pump automatically runs. After the standby duration is completed if the control system
still senses an overflow signal the machine gives “Call service” error message. The
system stops responding to any user input except the ON/OFF button.
If there is no overflow signal after 2 minute standby time the machine continue to
work normally.
Possible reasons:
•Broken components or torned hoses
•Malfunction of drain pump
•Malfunction of flowmeter
•Malfunction of water inlet valve
•Cable harness errors
•Faulty electronics
Sensitivity: Public
TROUBLESHOOTING- No Water [E:02]
Incoming water to the machine is monitored via a water counter (flow meter)
system. Water counter generates electronic pulses. During the “Water Inlet” step
(for any program including functional test) if no pulses could be sensed by the
electronics, No Water condition occurs. At this condition the dishwasher will wait
until water signal is detected. If necessary water signal is detected the machine
will continue its normal operation.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING- Heater Fault [E:03]
Possible reasons:
a. Malfunction of heater
b. Malfunction of NTC (constant NTC resistance)
c. Cable harness errors
e. Faulty electronics
Note: During the first 3 minutes of a heating step the water temperature is not
controlled. The control system waits so that the temperature inside the machine reaches
balance.
Sensitivity: Public
TROUBLESHOOTING- Turbidity Fault [E:04]
Turbidity sensor is the component that measures the amount of dirt in the
water. The machine uses this data for the steps of Auto Program (if
applicable). If the proper data from the turbidity sensor cannot be received,
Turbidity Sensor Error occurs. When the error occurs, the software
continues the program as heavy dirt level.
Possible reasons:
a.Malfunction of Turbidity Sensor
b.Cable harness errors
c.Faulty electronics
Sensitivity: Public
TROUBLESHOOTING
Diverter Valve Pos. Fault [E:05]
3Way / Multi Valve is the component that diverts the water flow between the
upper and lower trays independently. It is driven by the electronics and the
position of the valve is measured by a feedback signal. Diverter Valve Position
Error occurs if the proper position signal could not be received from the valve.
When the error occurs, the electronics drives the valve until proper position
signal is achieved.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING- NTC Fault [E:06]
At the Heating step, if NTC resistance is measured beyond the specified resistance
values or if the NTC resistance is measured as open/short circuit NTC fault occurs.
When the fault is detected software skips the heating step and continues the
program with the next step.
Possible reasons:
a.Malfunction of NTC
b.Cable harness errors
c.Faulty electronics
Sensitivity: Public
TROUBLESHOOTING- Water Inlet Valve Fault [E:07]
The electronics of the machine monitors water counter pulses at every step of
the washing program. If pulses are received from the counter at any step other
than Water-Inlet; Water Inlet Error occurs. When the fault is detected, software
drives the drain pump 1 minute then check the counter signal again.
- If the signal exists, that means the faulty condition does still continue. Then
drain pump is activated with 1 minute intervals (1 min ON, 1 min. OFF)
- Instead if the signal is stopped, then software continues with the selected
program.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
External Board Communication Fault [E:08]
During machine working cycle, if communication between main electronic board and
external electronic board is lost; this fault is encountered.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
Display Board Communication Fault [E:09]
During machine working cycle, if communication between main electronic board and
display electronic board is lost; this fault is encountered.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
Conducto Board Communication Fault [E:10]
During machine working cycle, if communication between main electronic board and
conducto electronic board is lost; this fault is encountered.
(This fault is encountered only in machines with conducto feature)
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
Conducto Probe / Short Circuit Faults [E:11 / E:12]
These errors are encountered when conducto probe cable harness occurs or cable
sockets installed in wrong direction.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
Pressure Switch Fault [E:13]
Machines with pressure switch feature, in washing cycle, after water inlet is completed
the pressure switch is clicked. If it is not, pressure swtch fault is encountered.
At the water inlet part of the programme, after enough amount of water is taken
into the sump (apprx 2,5 liter); pressure switch is expected to be clicked.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
Water Counter Fault [E:15]
At washing cycle water inlet step, if water counter does not increase but the pressure
switch clicks; main board software encounters «water counter» fault.
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
Drain Pump Blocked Fault [E:16]
Possible reasons:
Sensitivity: Public
TROUBLESHOOTING
Automatic Detergent Dosage Motor Positioning
Fault [E:17]
At liquid detergent dosing step, dosage motor tries to find right position.
If position can not be found in specified time interval, position fault counter is
increased. After 2 unsuccessfull try, electronic board gives [E:17] error.
Possible reasons: