Load Combination using Strength Design or Load and Resistance Factor Design
o 1.4(D+F)
o 1.2(D+F+T) + 1.6(L+H) +(L1 or R)
o 1.2D + 1.6(L1 or R) + (f1L or 0.8W)
o 1.2D + 1.6W + f1L + 0.5(L1 or R)
o 1.2D 1.0E + f1L
o 0.9D + 1.6W + 1.6H
o 0.9D + 1.0E + 1.6H
Load Combinations Using Allowable Stress Design
o D+F
o D+H+F+L+T
o D + H + F + 0.75[L + T + (L1 or R)]
o D + H + F + (W or E/1.4)
o D + H + F + 0.75[L + L1 + (W or E/1.4)]
o 0.60D + W + H
o 0.60D + E/1.4 + H
o D + L + L1(or R)
o D+L+W
o D + L + E/1.4
Special Seismic Load Combination
o 1.2D + f1L + 1.0Em
o 0.9D (+ or -) 1.0Em
Symbols and Notations
D = dead load
F = earthquake load set forth in Section 208.5.1.1 (NSCP)
Em = estimated maximum earthquake force that can be developed in the structure as set forth in
section 208.5.1.1
H = load due to lateral pressure of soil and water in the soil
L = live load, except roof live load, including any permitted live load reduction
L1 = roof live load, including any permitted live load reduction
R = rain load on the undeflected roof
T = self-straining force and effects arising from constraction or expansion resulting from temperature
change, shrinkage, moisture change, creep in components materias, movement due to different
settlements, or comibinations thereof
W= load due to wind pressure
f1 = 1.0 for floors in places of public assembly, for live loads in excess of 4.8 kPa, and for garage live load