August 12, 2019 CE 515 Assignment #2

The document provides load combination formulas for strength design, allowable stress design, and special seismic load combinations. For strength design, there are 7 load combination formulas listed using factors like 1.4, 1.2, 1.6, etc. For allowable stress design, there are 8 load combination formulas listed using factors like 0.6, 0.75, 1.0, etc. There are also 2 special seismic load combination formulas listed using factors like 1.2 and 0.9. The document defines symbols used in the load combination formulas like D for dead load, L for live load, W for wind load, and Em for estimated maximum earthquake force.

Uploaded by

Mj Cabanganan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views2 pages

August 12, 2019 CE 515 Assignment #2

The document provides load combination formulas for strength design, allowable stress design, and special seismic load combinations. For strength design, there are 7 load combination formulas listed using factors like 1.4, 1.2, 1.6, etc. For allowable stress design, there are 8 load combination formulas listed using factors like 0.6, 0.75, 1.0, etc. There are also 2 special seismic load combination formulas listed using factors like 1.2 and 0.9. The document defines symbols used in the load combination formulas like D for dead load, L for live load, W for wind load, and Em for estimated maximum earthquake force.

Uploaded by

Mj Cabanganan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

JOHN REY I.

ANDOYO BSCE5

August 12, 2019

CE 515

Assignment #2

 Load Combination using Strength Design or Load and Resistance Factor Design
o 1.4(D+F)
o 1.2(D+F+T) + 1.6(L+H) +(L1 or R)
o 1.2D + 1.6(L1 or R) + (f1L or 0.8W)
o 1.2D + 1.6W + f1L + 0.5(L1 or R)
o 1.2D 1.0E + f1L
o 0.9D + 1.6W + 1.6H
o 0.9D + 1.0E + 1.6H

 Load Combinations Using Allowable Stress Design


o D+F
o D+H+F+L+T
o D + H + F + 0.75[L + T + (L1 or R)]
o D + H + F + (W or E/1.4)
o D + H + F + 0.75[L + L1 + (W or E/1.4)]
o 0.60D + W + H
o 0.60D + E/1.4 + H
o D + L + L1(or R)
o D+L+W
o D + L + E/1.4

 Special Seismic Load Combination


o 1.2D + f1L + 1.0Em
o 0.9D (+ or -) 1.0Em

Symbols and Notations

D = dead load

F = earthquake load set forth in Section 208.5.1.1 (NSCP)

Em = estimated maximum earthquake force that can be developed in the structure as set forth in
section 208.5.1.1

H = load due to lateral pressure of soil and water in the soil


L = live load, except roof live load, including any permitted live load reduction

L1 = roof live load, including any permitted live load reduction

R = rain load on the undeflected roof

T = self-straining force and effects arising from constraction or expansion resulting from temperature
change, shrinkage, moisture change, creep in components materias, movement due to different
settlements, or comibinations thereof

W= load due to wind pressure

f1 = 1.0 for floors in places of public assembly, for live loads in excess of 4.8 kPa, and for garage live load

= 0.5 for other live loads.