Function Function Description Value


code
F00 - Basic Function Parameter Group
Drive Control mode:
1. V/F control
F00.01 2
2. SVC control (No encoder)
3. VFC control (with encoder)

Keypad control (0)


F00.02 1
Terminal control (1)
F00.04
Accelaration Time from 0 Hz to base
F00.14 40 s
frequency
Decelaration Time from base
F00.15 40 s
frequency to 0 Hz

Upper Limit Freq Control Options


0: Set through F00.18
1: AI1
2: AI2
F00.17 1
3: AI3
4: AI4 (Expansion Card)
5: High-Frequency Pulse Input (X7)
6: Communication Percentage

Running Direction
F00.20 0: Same 0
1: Opposite

Reverse Control
F00.21 0: Forward/Reverse allowed 0
1: Reverse not allowed
F01 - Motor Parameter

Motor Type
0: Induction Motor
F01.00 1: Inverter Induction Motor 1
2: Permanent Magnet Synchronous
Motor

F01.01 Motor Rated Power 250 kW


F01.02 Motor Rated Voltage 380 V
F01.03 Motor Rated Current 459 A
F01.04 Motor Rated Frequency 50 Hz
F01.05 Motor Rated Speed 1490 RPM
Motor Winding Connection
F01.06 0: Y 1
1: Δ
F01.07 Motor Rated Power Factor 0.87
F01.08 Motor Rated Effeciency 95.10%
F00.09 - F00.13 set through autotuning (F01.34)

Encoder Type
0: ABZ Incremental Encoder
1: UVW Incremental Encoder
F01.24 0
2: UVW Wire-Saving Encoder
3: Not Used
4: Rotary Transformer

F01.25 Encoder Resolution 1024


AB Pulse Phase Sequence
F01.27 0: Forward 1
1: Reverse
Speed Feedback Disconnection
F01.32 0.4 s
Detection Time

Motor Parameter Autotuning


0: No Autotuning Select required value
1: Stationary Autotuning of
F01.34 and press "RUN" on
Induction Motor keypad
2: Rotational Autotuning of
Induction Motor

F02 - Input Terminal Function Group


F02.31 0: Analog Input 0
F03 - Output Terminal Function Group
F03.00 Y1 Output (Inverter Running) 1
F03.31 Y2 Output (Inverter Fault) 7
F03.21 Analog Output M1 4 - Output Current
0 - Running Speed
F03.22 Analog Output M2 (Frequency)
F12 - Kwypad & Display Function Group

Parameter Copy
0: No operation
F12.03 0
1: Upload parameter to keypad
2: Download parameter to inverter

F12.14 Factory Reset 1