NR keeping the lights on

Practice, Improvement, Cooperation and Innovation

Copyright
Copyright © NR 2012.01. All rights reserved

We reserve all rights to this document and to the information contained herein. Improper use
in particular reproduction and dissemination to third parties is strictly forbidden except where
expressly authorized.

The information in this manual is carefully checked periodically, and necessary corrections
will be included in future editions. If the user nevertheless detects any errors, he is
appreciated any suggested correction or improvement.

We reserve the rights to make technical improvements without notice.

Manufacturer:
NR ELECTRIC CO., LTD.
69 Suyuan Avenue, Jiangning, Nanjing 211102, China
Tel: +86 25 8717 8888
Fax: +86 25 8717 8999
www.nrelect.com
E-mail: [email protected]
[email protected]

read more on www.nrelect.com 3


CONTENTS

COMPANY PROFILE 6

Company Profile ........................................................................... 6 RCS-9621 Transformer Management Relay .................................... 140

Product Portfolio ........................................................................... 7 RCS-9661 Transformer Auxiliary Relay ............................................. 144

RCS-9622 Transformer Management Relay ..................................... 147

SOLUTIONS 8 RCS-9624 Transformer Management Relay ..................................... 151

Solutions for Power Grid ..................................................................... 8

Solutions for Power Plant ................................................................... 11


Reactor Protection .............................................................. 155

Solutions for Industrial ........................................................................ RCS-917 Reactor Protection ............................................................. 156


14

Solutions for Integrated Secondary System ...................................... RCS-9647 Reactor Management Relay ............................................ 160
16

Solutions for Power Electronics ......................................................... 23

Solutions for HVDC & VSC-HVDC .................................................... 30


Circuit Breaker Protection ............................................ 164

PCS-921 Breaker Failure Protection ................................................. 165

RCS-921 Breaker Failure Protection ................................................. 169


ENGINEERING SERVICES & TRAINING 22
RCS-923 Breaker Failure Protection ................................................. 173

PCS-9830 Point-on-Wave Controller of CB ...................................... 177


PROTECTION & CONTROL 36

Transmission Line Protection ..................................... 36


Generator and Generator-Transformer
PCS-902 Line Distance Relay ........................................................... 37 179
Unit Protection ......................................................................
RCS-902 Line Distance Relay ........................................................... 42
PCS-985 Generator-Transformer Unit Protection ............................. 181
PCS-931 Line Differential Relay ....................................................... 47
RCS-985A/B/C Generator-Transformer Unit Protection ..................... 187
RCS-931 Line Differential Relay ....................................................... 53
RCS-985G Generator Protection ...................................................... 192
RCS-901 Line Directional Comparison Relay .................................. 58
RCS-985RS/SS Generator Protection .............................................. 197
RCS-941 Line Distance Relay ........................................................... 62
RCS-985T Transformer Protection .................................................... 201
RCS-943 Line Differential Relay ....................................................... 66
RCS-985TS Transformer Protection ................................................. 205
PCS-924 Stub Differential Relay ...................................................... 70
RCS-9659 Auto Synchronizer ........................................................... 209
RCS-924 Stub Differential Relay ...................................................... 74

RCS-922 Stub Differential Relay ....................................................... 78


Distribution Feeder Protection and Control ........ 213
RCS-925 Voltage Relay with Transfer Trip Supervision .................... 82
PCS-9611 Directional Overcurrent Protection ................................... 214

RCS-9611 Feeder Management Relay ............................................. 219


Busbar Protection ............................................................... 86 RCS-9613 Feeder Differential Relay ................................................. 223
PCS-915IC Centralized Busbar Protection ....................................... 87 RCS-9615 Feeder Management Relay ............................................. 227
PCS-915ID Distributed Busbar Protection ........................................ 92 RCS-9625 Feeder Management Relay ............................................. 231
RCS-915 Centralized Busbar Protection .......................................... 97
PCS-9651 Automatic Transfer Relay ................................................ 235
RCS-9628 Busbar Voltage Relay ...................................................... 101
RCS-9651 Automatic Transfer Relay ................................................ 239

RCS-9629 Automatic Transfer Relay ................................................ 243


Transformer Protection ................................................... 105 PCS-9655 Fast Transfer Devices ...................................................... 247
PCS-978 Transformer Protection ...................................................... 106 PCS-9691E Overcurrent Protection .................................................. 251
RCS-978 Transformer Protection ...................................................... 112

PCS-974 Transformer Auxiliary Relay ............................................... 116


Motor Protection .................................................................. 255
RCS-974 Transformer Auxiliary Relay ............................................... 120 RCS-9641 Motor Management Relay .............................................. 256
PCS-9671 Transformer Differential Relay ......................................... 124 RCS-9642 Motor Management Relay .............................................. 260
RCS-9671 Transformer Differential Relay ......................................... 128 RCS-9626 Motor Management Relay .............................................. 264
RCS-9679 Transformer Protection .................................................... 132 RCS-9627 Motor Management Relay .............................................. 268
RCS-9681 Transformer Overcurrent Relay ....................................... 136

4 read more on www.nrelect.com


Capacitor Protection ......................................................... 272 STABILITY CONTROL SYSTEM 335
RCS-9631 Capacitor Management Relay ......................................... 273 Power Stability Control System (PSCS) ........................................ 335

PCS-993 Out-of-Step Controller ....................................................... 337

Arc Protection ....................................................................... 277 RCS-993 Out-of-Step Controller ....................................................... 341

PCS-9656 Arc Protection System ..................................................... 277 PCS-994 Frequency & Voltage Controller ........................................ 345

RCS-994 Frequency & Voltage Controller ........................................ 349

AUTOMATION 337
SMART SUBSTATION SOLUTION 279
MEASUREMENT & RECORDING 353
PCS-221 Merging Unit ..................................................................... 279
PCS-996A Phasor Measurement Unit .............................................. 353
PCS-222 Circuit Breaker Controller ................................................. 282
PCS-9013 DFR Management System .............................................. 358
PCS-223 CB Online Monitoring Unit ................................................ 285
PCS-996R Disturbance Fault Recordor ............................................ 359
PCS-9250-EGI/EAI Electronic CT/VT .............................................. 286
PCS-996S Disturbance Fault Recordor ........................................... 363
PCS-9250-OAI Optic Current Transformer ...................................... 289
PCS-986 Disturbance Fault Recordor ............................................... 367

SUBSTATION AUTOMATION SYSTEM 290

PCS-9700 Substation Automation System ........................................ 290


ENERGY MANAGEMENT 371
PCS-9000 Energy Management System (EMS) .............................. 371
PCS-9700 HMI .................................................................................. 295
PCS-9002 Distribution Management System (DMS) ....................... 373
PCS-9705 Bay Control Unit (BCU) .................................................. 296

RCS-9700C Bay Control Unit (BCU) ................................................. 299

RCS-9698G/H Gateway .................................................................... 303

RCS-9794A/B Protocol Converter .................................................... 306 HVDC & VSC-HVDC 375

PCS-9881/9882 Ethernet Switch ..................................................... 309 PCS-9550 HVDC Control & Protection System ................................. 375

RCS-9785C/D GPS Synchronization Clock ..................................... 312 PCS-9250 DC Electronic CT/VT ....................................................... 378

RCS-9785E Time Pulse Extension Equipment .................................. 315

COMMUNICATIONS 380

POWER PLANT AUTOMATION SYSTEM 318 MUX-2M/MUX-64 Interface Unit ...................................................... 380

PCS-9100 Distribution Control System for Thermal Control (DCS) ... 318 PCS-912/913 Power Line Carrier Transceiver .................................. 382

PCS-9700 Electrical Control System for Motor Control (ECS) .......... 320

PCS-9700 Network Control System for Power Station (NCS) ........... 321

PCS-9400 Generator Excitation System ........................................... 322 ACCESSORIES 385

PCS-9575 Static Frequency Converter (SFC) ................................... 324 CJX/CZX-12R/CZX-22R Interposing Relay Set ............................... 385

NR0500 Operating Relay .................................................................. 388

RCS-9662 Auxiliary Relay Set ........................................................... 390

FLEXIBLE AC TRANSMISSION SYSTEM 325 Relay Connection Terminals ............................................................. 392

PCS-9580 Static Var Compensator (SVC) ........................................ 325 Installation Instruction ....................................................................... 395

PCS-9583 Static Synchronous Compensator (STATCOM) ............... 328

PCS-9590 DC De-Icer ....................................................................... 329

PCS-9570 Fixed Series Compensator (FSC) .................................... 330 SOFTWARE KIT 396
PCS-Explorer ...................................................................................... 396

POER STABILITY CONTROL SYSTEM PCS-PC Software Kit ........................................................................ 398

RENEWABLE ENERGY INTERCONNECTION 331 RCS-PC Software Kit ........................................................................ 400

PCS-9563 PV Grid-Interconnection system ...................................... 331 SCL Configuratiom Software Kit ....................................................... 402

PCS-9561 Doubly Fed Converter System ......................................... 333

APPENDIX ................................................................................ 404

read more on www.nrelect.com 5


Benefited by the wide use of our products and an extremely high
correct operation rate of NR's digital relays, the Chinese power
system stability level is largely heightened. The probability of
mal-operation under a fault or normal service condition in the
Chinese power systems has been significantly reduced.

NR has been developing rapidly and has become the largest


research and manufacturing-based enterprise of digital
protection, control and monitoring system in China. It has grown
steadily since its start and has built a good reputation for robust
hardware and well-designed software in our protective relays
and systematic solutions. NR can undertake turnkey engineering
projects for protection and control systems of substations and
power plants. Furthermore, we are dedicated to provide high-
quality and complete solutions for protection and control system
to customers, incorporating devices, design, installation, test
and after sale service. Additionally, NR offers customized
system solutions according to actual on-site conditions in order
to satisfy customers’ requirements.

In recent years, NR is continuously improving its localization


level to realize fast and professional pre-sale and after-sale
COMPANY services. So far, NR has founded subsidiaries and established
technical service centers in different regions all over the world.

PROFILE Call NR's qualified subsidiaries or technical service centers, our


technicians will perform in-depth diagnostics and professional
consultancy to quickly get your device back into service.

NR Electric Co., Ltd. (NR) is one of the leading manufacturers


in the world on the research and manufacturing of digital
protection, automation and control systems for both HVAC and
HVDC power systems. As an engineering-driven company, NR
is committed to serving electric of power utility and industrial
customers with a complete family of product lines.

With innovative and patented technologies such as Deviation of


Power Frequency Component(DPFC) method and power swing
blocking method, NR's digital protective relays have helped to
detect and clear faults quickly during the development of 220kV
to 1000kV transmission systems in China and other countries.
Information on current and voltage measurement, protection,
control, metering and monitoring in our digital relays can greatly
help power utilities to measure power status and improve power
quality accurately.

6 read more on www.nrelect.com


PRODUCT
PORTFOLIO

read more on www.nrelect.com 7


SOLUTIONS

Solutions
for Power Grid
With innovative technologies and years of operational faults within a sub-cycle time and is immunity to power swing,
experiences, NR offers practical solutions for power grid all heavy load and weak-infeed, and is capable to detect high
over the world, including engineered packages and turnkey resistance faults. During power swing, the Power Swing
solutions for new constructed and referbishment projects. The Blocking Logic can properly block distance elements, keep
scope ranges from transmission to distribution substations and stable to an external and quickly clear an internal fault.
systems from 10 kV to 1000 kV.
The PCS/RCS-9700 is an innovative automation solution for
substations, generations and industrials with many advanced
Transmission technologies and patents. It integrates the application of
NR protective relays are designed based on Deviation of Power protection, control, Ethernet, IT and communication technology
Frequency Component (DPFC) and power swing blocking based on international standard. The PCS/RCS-9700 adopts
principles which have successfully brought in a combination layered distributed architecture with bay-oriented and object-
of quick reaction time and reliability, thereby meeting the oriented structure to build a more reliable and easier system for
requirements of power system safety and stability. The unique the future extension and maintenance.
DPFC incremental-quantity distance element can clear internal

8 read more on www.nrelect.com


- Smart Substation with Process Bus
NR provides a complete smart substation solution for power
grid customers with leading technologies on Non-Conventional
Instrument Transformer, Merging Unit and Circuit Breaker
Controller.

NR's Smart Substation Solution consists of process bus and


station bus. The process bus employs IEC 61850-9-2 Sampling
Double-Star Ethernet Structure of PCS-9700 Automation Value, IEC 61850-8-1 GOOSE for time-critical message and
System Complied with IEC61850
IEEE 1588, supporting flexible network topologies including
Point-to-Point optical communication and Double-Star Ethernet.

The station bus employs IEC 61850-8-1 MMS, GOOSE


message and SNTP. It supports Double-Star Ethernet and
Single- or Double- Ring Ethernet.

NR offers a full range of Smart Substation products, including:

• 10kV-800kV Electronic CT/VT and Optical CT for GIS and


AIS
• M e r g i n g U n i t s u p p o r t i n g c o n v e n t i o n a l a n d N o n -
conventional CT/VT
• Circuit Breaker Controller executing binary inputs/outputs
for Breaker/Isolator/Earth Switch via GOOSE message
Double-Star Ethernet Structure of PCS-9700 Automation • Protection and Control complying with IEC 61850-9-2 and
System Complied with IEC61850
GOOSE message
• Gigabit Ethernet Switch for process bus and station bus
The integrated design of PCS/RCS-9700 considerably reduces • IEC 61850 Protocol Converter for third-party IED
the cost of multiple stand-along devices. Direct connections
• Clock Receiver providing IRIG-B/SNTP and IEEE1588
among bay-level devices and dual Ethernet networks enhance
clock signal
reliability of the substation automation system.
• Gateway supporting IEC 61850
- IEC 61850 • HMI Software for IEC 61850 substation
The IEC 61850 standard provides an internationally recognized
method targeted interoperability between IED from different - Energy Management System (EMS)
venders. NR’s substation automation system is fully compatible PCS-9000 energy management system(EMS) is a computer-
with IEC 61850 standard and has passed the IEC 61850 aided tool used by dispatchers of electric utility grids to monitor,
conformance test and obtained the level A certification issued by control, and optimize the performance of the generation and/or
KEMA. We also provide solutions that allow the migration from transmission system. It adopts advanced network management,
the conventional substation automation systems to the new object-oriented database and visualized cross-platform
standard. technology. The system operates based on the latest IEC61970
standard, providing a unified application platform for large scale
energy management of power enterprises.

The PCS-9000 energy management system includes SCADA,


Automatic Generation Control(AGC), Power Advanced
Software(PAS), Dispatching Training Simulator(DTS), AVC,
WAMS, OMS and WEB applications. It also can be easily
integrated with other systems conformed to IEC61970 standard
to protect the existing investments and reduce function
redundancy.

Smart substation system structure

read more on www.nrelect.com 9


Distribution
- Distribution Management System
NR’s PCS-9002 is a state-of-the-art Distribution Management
System intended for application in remote control center,
distribution networks and substations. It provides full scheme
protection, control and monitoring to ensure the reliable and
economical operation of distribution system.

The management stations communicate with sub-stations via


PCS-9882 Industrial Ethernet Switch using IEC 61970 and IEC
61968 protocol. The PCS-9002 manages the whole distribution
system and enhances economic benefits by introducing the
A typical power stability control system
integration of real-time data acquisition, distribution automation
and management, and places emphasis on the application
of distribution job management and related system data
interactions. The self-developed and customized working-flow - Power Stability Control System (PSCS)
management platform substantially improves management The power system is a highly nonlinear system in which a
disturbance can result in an unbalance state between loads and
efficiency.
generations. With the increase in the indispensability of electric
power in our daily life, power stability is always considered as
- Control & Monitoring an important factor for safe system operations.
• Distribution Terminal Unit (DTU)
Distribution Terminal Unit(DTU) can provide realtime SCADA NR's unique Power Stability Control System(PSCS) is based
control and monitoring, fault detection, distribution automation, on the three defense lines principle to guarantee the stability
VQC and communication management for 10kV switchyard and of power grids and effectively avoid severe large area outage.
main ring unit. A typical power stability control system consists of one master
station, several sub-master stations and execution stations.
• Feeder Terminal Unit (FTU) Communications between two stations adopt optical fibers.
Feeder Terminal Unit(FTU) is designed to provide monitoring The PSCS can provide realtime monitoring of power flow in the
and control of circuit breaker for 10kV distribution overhead entire power grid, and take measures under abnormal situations
lines. It can be installed directly on the outdoor tower. to maximally prevent the power grid from large area blackouts.
These emergency measures include voltage and frequency
• Transformer Terminal Unit (TTU) control, out-of-step islanding, load shedding and generator shut-
Transformer Terminal Unit(TTU) can provide realtime monitoring, down.
fault detection, data statistics, VQC and communication
management functions for distribution transformers and - RCS-992 Stability Controller
overhead distribution transformer. The RCS-992 stability controller is composed of one Central
Unit(CU) and up to 6 Bay Units(BU). Communications between
central unit and bay units are via dedicated point-to-point optic
fibers using IEC60870-5-103 or IEC61850 communication
System Protection Scheme (SPS) protocol. Communications between stability controllers can be
realized by dedicated optic fibers or SDH networks.
- Three Defense Line Principle
3-Defense-Line covers all stages of cascading progress: - RCS-993 Out-of-Step Controller
• First Defense Line: Clear faults by protective relays The out-of-step controller RCS-993 can effectively prevent
quickly and accurately system collapse by tripping the circuit breakers to separate
the power system into several smaller islands, shutting down
• Second Defense Line: Implement load-shedding and
generator shutting-down by Power Stability Control generators, shedding loads and/or starting synchronizer to
System (PSCS) prepare for the system synchronism after system islanding.

• Third Defense Line: Island regional power grid by


- RCS-994 Frequency & Voltage Controller
Out-of-Step relays or F/V control devices
The RCS-994 Frequency & Voltage controller can provide
emergency voltage and frequency control by starting up or
NR's provides system protection scheme(SPS) to save the shutting down generators to balance the generations and loads.
system from a blackout which may appear after the clearance
of a severe disturbance in a stressed operation situation or after
an extreme load growth.

10 read more on www.nrelect.com


Solutions
for Power Plant

With proven technologies and abundant operating experiences, - Generator & Generator-Transformer Unit
NR is dedicated to working on the protection and automation The microprocessor based generator-transformer unit protection
solutions for power plants with unit capacity up to 1000MW. provides comprehensive protection, control and monitoring
The scope ranges from conventional to renewable based power for small to large generators, generator-transformer units,
generation, covering thermal power plants, nuclear power plants, transformers, excitation transformers and exciters. Transformer
hydro power plants, wind power plants and solar power plants. auxiliary relays are provided to provide the mechanical signals
NR's innovative total solutuions and products help optimize such as thermal, gas, oil temperature, winding temperature,
performance, improve reliability, enhance efficiency and minimize pressure, oil level and so on.
environmental impact throughout the plant life cycle.
- Generating Station
Protection, Control & Monitoring NR offers PCS/RCS-900 series high integrated protection and
NR provides cost-effective solutions for the protection, control control devices to generating station in power plants to maintain
and monitoring of power plant assets, including electrical the best quality of service available and communication
protection and field excitation control for generators, mechanism capabilities.
protection for transformers and thermal control for rotors.

read more on www.nrelect.com 11


12 read more on www.nrelect.com
- Auxiliary Power power system with capacity up to 1000MW in a power plant. It
The PCS/RCS-9600 series devices are specially designed provides high performance control and monitoring for feeders,
for auxiliary power systems with capacity up to 1000MW. startup/standby transformers, auxiliary transformers and other
It is available along with a wide integration of protection, intelligent devices. The system adopts bay-oriented distributed
measurement, monitoring and control functions. It adopts GPS architecture to make system more reliable, easier to extend and
time synchronization which is compatible with second pulse, maintain.
minute pulse and IRIG-B.
- Network Control System (NCS)
- Motor Control for Power Plant Station
NR's PCS-9690 series digital protection and control devices The PCS/RCS-9700 network control system is an automation
are designed for PCC and MCC system from 380V to 600V system intended for the control of transmission lines, substations
(phase to phase), including protection, control, monitoring and and generators with capacity up to 1000MW in a power plant. It
communication. This series can be used as the protection and provides advanced automatic functionality including the safety
control of motors, feeders, bus sections and circuit breakers. monitoring of primary devices and the real-time monitoring of
electric parameters. The system adopts layered distributed
architecture to replace the traditional centralized structure to
Generator Excitation System enhance reliability and to easy maintainance. NR’s PCS/RCS-
The PCS-9400 Generator Excitation System provides excitation 9700 series NCS system is fully compatible with the IEC 61850
current and excitation regulations for high performance control standard and it has been used in power plants and put into
of all kinds of synchronous machines (motors and generators). service successfully already.
It integrates power system stabilizer, optimum control, adaptive
control and can be applied to synchronous machines with - Distributed Control System (DCS)
for Thermal Control
different excitation modes.
The PCS-9100 distributed control system provides process
control for all kinds of power plants. It integrates NR's

Automation technical advantages in power plant and thermal metering to


form a comprehensive control platform. It adopts distributed
- Electrical Control System (ECS) for
architecture and provides diagnosis in each branch circuit. So
Auxiliary Power System
far, the PCS-9100 has been put into service in many power
The PCS/RCS-9700 electrical control system is a cost-
plants with installed capacity up to 600MW.
effective automation system for the applications to auxiliary

read more on www.nrelect.com 13


Solutions
for Industrial

The rapid developed indutrial plants requires flexible, ease to to feeders, capacitor banks, reactors and motors in 380V power
use and high efficiency solutions with ability to withstand severe system of industrial enterprises. The PCS-9700M automation
environment. From reliable power generation to automation and system consists of 6kV/600V explosion-proof bay control unit,
remote monitoring, NR can help meet power demands, improve explosion-proof communication gateway, Ethernet switch,
power efficiency and protect plant assets, to achieve critical subsurface video monitoring system, ground monitoring master
demands and high operational efficiency. station and EMS for coal mine shaft.

Uninterrupted power supply is an critical requirement that


Metals and Mining unexpected power disruptions can cause complete loss of
NR provides reliable protection, control and monitoring to production and long stoppage time. NR's industrial solutions
safeguard metals and mining enterprises. Communications integrate fast transfer device and Power Stability Control
between protection rooms and control rooms are realized by System (PSCS), enabling the optimum safeguarding of energy
industrial fieldbus or Ethernet network. supply and stable system operation. The fast transfer device
ensures the continued supply through automatic transferring to
Overcurrent relays with auto-reclosing selective short-circuit a stand-by feeder to avoid expensive stoppage time. The power
protection functions are specially designed for the applications stability control system provides realtime monitoring of power

14 read more on www.nrelect.com


flows in the entire power networks in coal mining enterprise, and It also integrates automation functions such as disturbance fault
takes measures under abnormal situations to maximally prevent recording, to increase the reliability and safety of control and
the coal mining enterprise from blackouts. monitoring system.

Transportation
- Electrified Railway
NR’s PCS-9680 series devices feature the integration of
protection, monitoring and disturbance recording functions in
one rack, providing safeguard and guarantee of economical
operation for the entire electrified railway system. The PCS-
9680 series covers transformer protection, feeder protection,
capacitor protection and automatic transfer device. It introduces
harmonics blocking and self-adapting harmonics restraint Commercial Buildings
functions to solve the impact and harmonics caused by loads in NR’s power protection, process control and automation products
electric traction feeding system. can guarantee the uninterrupted supply during a power outage
for different mission-critical applications. NR’s customized
system solutions and complete products series provide highly
reliable safeguarding of business and public entities and have
been well proven in many world famous projects, such as 2008
Beijing Olympic Stadiums and 2010 World Expo in Shanghai.

- Metro Railway
As an important part of metro power supply system, the safe
operation of 110kV/35kV substation will affect the stability of
the entire metro system. The RCS-9600CS series are well
proven products that can provide protection and monitoring for
transmission line, feeders, and transformers in the 110kV/35kV
substation. The RCS-9700 substation automation system Electronics
integrates the protection, control, Ethernet and communication NR can provide reliable power protection, communications and

technology, enabling the implementation of unattended management systems to ensure the uninterrupted power supply

operation for 110kV/35kV metro substation. for electronic manufacturers. NR’s innovative protection devices
and fast transfer devices can quickly detect faults and trip the
faulty line to prevent severe disaster. The fast transfer devices

Oil and Petrochemical minimize production interruptions to save money.

NR’s provides highly reliable, economical and flexible solutions


are suitable for severe conditions of oil and petrochemical
industries, and are able to integrate into any existing systems.

The RCS-9600CS series and PCS/RCS-9700 products can


provide protection, monitoring and automation for expensive
equipments and increase the reliability of primary instruments.

Government & Military


As a trusted relay manufacturer, NR provides protection, power
management system, metering, communication and time
synchronization devices to many mission-critical national and
military projects.

read more on www.nrelect.com 15


With tens of years’ researches and operational
experiences in power secondary system, NR developed
the unified and integrated solutions of the whole
secondary system for power grid, including station
level, network level & communication infrastructure.
The utility consumers could benefit from the Integrated
Secondary System (ISS) to optimize energy generation,
transmission, distribution and consumption.

Solutions for Integrated Secondary System (ISS)

In station level, it integrates protection, control, monitoring, metering, recording and communication in substation.
In network level, it provides Energy Management System (EMS), Distributed Management System (DMS), Tele-
Meter Reading (TMR), Power Stability Control System (PSCS), Wide Area Measurement System (WAMS),
Disturbance Management System, Relay Management System and CCTV Management System. In addition, the
communication infrastructures between substations and
dispatching center are integrated in the system. Inside the
dispatching center and substations, the LAN is used for the
internal communication. WAN and/or SDH/SONET networks
are adopted for the inter-station communications according
to the specific application.

The utilities could obtain the unified management system


of the whole network from the dispatching center to the
substations. All the data is classified and shared by all points
in the utility level. The unified data format realizes the easy
extending of new applications. The cyber security is acquired
via the authorization and hardware security devices.

16 read more on www.nrelect.com


Protection & Control

NR’s is dedicated to providing diverse protection & control products with well-proven
technologies that has been widely used in thousands of projects worldwide. The
protection & control solution covers all primary assets, including generator, transformer,
transmission line, busbar, circuit breaker, reactor, capacitor, motor and beyond.

In the hardware platform, the innovative two-out-of-two logic is adopted to avoid the
mal-operation due to the failure of any component. Dependability and security are
obtained via the redundant scheme and the unique two-out-of-two logic. As well, NR has
a good understanding of protection theory and created many innovative technologies
or patents to improve the protection performances. The protection principle based on
Deviation of Power Frequency Component (DPFC) was firstly introduced by NR that it
can clear the short-circuit fault in an extreme short time. According to the field records,
the fast distance protection using DPFC operated in 3ms for the close-in fault of a
500kV transmission line. The unique power swing blocking logic can properly supervise
the distance protection as well as correctly trip the internal fault during power swing via
the independent detector element for the fault with power swing. In busbar protection,
the patented weighted anti-saturation algorithm is integrated in the current differential
protection to keep security to external fault and quickly clear internal fault during CT
saturation. The transformer protection adopts adaptive-blocking and cross-blocking
methods for inrush current to improve the performance.

For power generation, NR provides generator-transformer unit protection, generator


protection and transformer protection. The generator-transformer unit protection
provides “all-in-one” solution for generator-transformer unit, generator, main transformer,
up to 3 auxiliary transformers and excitation system.

read more on www.nrelect.com 17


Solutions for Integrated Secondary System (ISS)

Smart Substation Solution

With the development of information technology, the communication is extended to the switchyard
and the substation is evolving from Substation Automation System (SAS) to Smart Substation
Solution, becoming an important part of Smart Grid.

NR provides a complete smart substation solution for power grid customers with leading
technologies on Electronic and Optical CT/VT, Merging Unit and Circuit Breaker Controller. NR’s
Smart Substation Solution consists of process bus and station bus. The process bus employs
IEC 61850-9-2 Sampling Value, IEC 61850-8-1 GOOSE for time-critical message and IEEE 1588,
supporting flexible network topologies including Point-to-Point optical communication and Double-
Star Ethernet. The station bus employs IEC 61850-8-1 MMS, GOOSE message and SNTP. It
supports Double-Star Ethernet and Single- or Double- Ring Ethernet.

Communications between equipments can be


realized by fiber links in the entire substation.
The unique smart solution is suitable for new
constructed and refurbishment substations.
The merging units not only support connections
to electronic CT/VT and optical CT, but also
conventional CT/VT. NR also offers full products
series to support the implementation of smart
substation solutions, including 10kV-800kV
Electronic CT/VT and Optical CT for GIS and
AIS, Merging Unit supporting conventional
and Non-conventional CT/VT, Circuit Breaker
Controller executing binary inputs/outputs for
Breaker/Isolator/Earth Switch via GOOSE
message, Protection and Control complying with
IEC 61850-9-2 and GOOSE message, Gigabit
Ethernet Switch for process bus and station bus,
IEC 61850 Protocol Converter for third-party
IED, Clock Receiver providing IRIG-B/SNTP and
IEEE 1588 clock signal, Gateway supporting IEC
61850, HMI Software for IEC 61850 substation.

18 read more on www.nrelect.com


Substation Automation

Substation automation system is a mature method to manage substations and optimize the power
operation performance. Automation system is provided for assets management in substation,
power system status monitoring, remote/local control, fault analysis & evaluation, operators’
authorization, history data statistic & analysis and communication to load dispatching center. It
manages utility assets, monitors operation states and measures load profile. All the information is
collected and visually displayed in the control room. Operators can execute the remote control and
interlocking via the workstation.

NR provides the integrated automation solution for new substation or retrofit substation, covering
consulting, design, supply, installation, training, commissioning & trial operation. The solution is
totally complied with IEC 61850 over double-star LAN or ring LAN. NR has set up its own IEC
61850 Level B Laboratory which can help check the compliance with IEC 61850. As well, NR’s
IEDs has certified by KEMA for the IEC 61850 conformance. NR supplies the complete products
for substation automation system, including Bay Control Unit, Protective Relay, Fault Recorder,
PMU, Protocol Converter, Gateway, GPS Receiver, Gigabit Switch and HMI Software. NR can
also integrate the metering and CCTV into the automation system.

In NR’s solution, the redundant scheme is comprehensively considered, such as redundant server
& database, redundant network, redundant gateway, redundant GPS receiver and redundant
protocol converter. Standby system will be automatically switched to active state during the hot
system failure in a very short time.

read more on www.nrelect.com 19


Solutions for Integrated Secondary System (ISS)

Energy Management

Energy Management System (EMS) and Distribution Management System (DMS) monitor,
manage and optimize the energy generation, transmission, distribution and consumption to help
the utility or industrial customers to maximize efficiency and minimize cost. It supervises the whole
power network and produces the accurate control strategy to realize the energy optimization.

NR’s Energy Management System provides the versatile interfaces and protocols for connection
with RTU or Gateway in substations, such as IEC 61870-5-101, IEC 61870-5-104, DNP 3.0. The
redundant scheme of server, database and communication is adopted to improve the reliability. It
fully complies with IEC 61970 standard, providing a unified data platform based on CIM (Common
Information Model).

NR’s EMS solution provides diverse functions that are tailored according to the specific project
requirements. It provides the Supervisory Control and Data Acquisition (SCADA), Automatic
Generation Control (AGC), versatile Power Application Software (PAS), Dispatcher Training
Simulator (DTS), Wide Area Measurement System (WAMS) and Tele-Meter Reading (TMR).
Because all the data acquired from the substations is stored in the unified database with
standardized access interfaces, the application function is easily expandable to meet the specific
application.

20 read more on www.nrelect.com


Stability Control

Blackouts will cause serious impacts to the modern society from economy to life, particularly critical to the important
institutes, such as hospital, underground mine, gas station, sewage treatment plants, etc.

NR provides the well-proven three-defense-line solution to improve the power system stability and significantly
reduce the blackouts. The first defense line means the reliable and high-speed relays that can clear the faults
correctly and fast, especially the reasonable actions during system oscillation, unstable frequency and unstable
voltage.

The unique second defense line is the innovative Power Stability Control System (PSCS) that provides the system-
level solution for the whole power grid. Different from other System Protection Schemes (SPS), the PSCS is based
on instability prediction instead of instability measurement. Before the installation, the tactic table is pre-determined
and simulated according to the previous stability study and strategy analysis. After installation, PSCS acquires all
the necessary real-time data from the substations or power plants and seeks the appropriate remedy actions in the
tactic table to pull the power system back to stability state BEFORE the system goes into instability state. Other SPS
only detects the system parameters and take actions AFTER the system enters instability state.

The third defense line is the out-of-step controller and frequency/voltage controller. These controllers detect the
system parameters and take actions to prevent the expansion of instability. Generally a basic requirement for
these controllers is that they should not operate during short-circuit fault which would be cleared by the protective
relays. Vice versa, the relay should not operate during system instability and leave it for the controllers to take
measurement.

The after-disturbance analysis is important to discover the potential problems in power system and help customers
enhance the system reliability. Generally the disturbance recording function using the dedicated Disturbance &
Fault Record (DFR) or integrated in the protective relay is applied in the substations and power plants to collect the
disturbance data.

read more on www.nrelect.com 21


Recording & Measurement

NR provides the dedicated DFR to record the disturbance information including analog and
digital quantities to help verify the proper operation of protection & control devices and analyze
the potential problem in power system. To enhance the analysis capability, NR provides the
DFR management system based on the system-level data for the regional network and wide
area network. It connects with the DFRs in all substations and collects the disturbance data of
the whole power network. Engineers can analysis the disturbance cases using the data of the
complete network. The disturbance management system adopts IEC61850, FTP and IEC60870-5-
103 based on SDH/SONET or WAN.

Phasor Measurement Unit (PMU) installed in the substations measures and sends the phasor to
the remote control center. The operator could visually view the synchronized phasors of the whole
power grid via the Wide Area Measurement System (WAMS), as well it could help the operators
make a correct decision to take remedy actions for power stability.

NR provides the complete solution of WAMS including the PMU and PDC (Phasor Data
Concentrator). The WAMS software package installed in the dispatching center collects all the
pahsor data from PMU and PDC in all substations and shows all the synchronized phasors to
operators. The PMUs and PDCs communicate with the dispatching center via SDH/SONET or
WAN.

22 read more on www.nrelect.com


Power electronics technologies, such as valve banks and thyristor control,
are widely used in power systems in the areas of Flexible AC Transmission
System (FACTS) and renewable energy interconnection. The application
of power electronic can enhance power system controllability, playing an
important role in smart grid. Due to the power electronic features, these kind
of equipment applied in power system could control power flow, increase
transmission capability, reduce voltage fluctuation, compensate reactive
power, improve stability, improve power quality and implement interconnection
of renewable energy or distributed generation/storages.

Solutions for Power Electronics

As a comprehensive solutions provider, NR well introduces innovative power electronic


technologies in power system applications to present true break-through solutions to optimize
existing and new AC systems, increase system reliability & availability, improve dynamic system
stability both during and after faults and increase power quality for sensitive industries. The power
electronic can increase transfer capacity, reduce losses and maintain voltage profile under many
network operating conditions.

NR provides innovative power electronic products based on both Current-Sourced-Converter


(CSC) and Voltage-Sourced-Converter (VSC), including Static Var Compenstaor (SVC), Static
Synchronous Compensator (STATCOM), De-Icer with SVC function, Fixed Series Compensator
(FSC), wind energy converter for interconnection, photovoltaic inverter for interconnection, Static
Frequency Converter (SFC) and generator excitation system.

read more on www.nrelect.com 23


Solutions for Power Electronics

Static VAR Compensator (SVC)

Reactive power is necessary to power system and plenty of power components can generate
or absorb reactive power. The balance of reactive power is an important issue since it is relative
to the system voltage. Generally the reactive power should be locally compensated to avoid the
transmission in power network so as to reduce losses.

The installation points of SVC in the network will be determined based on the system study.
SVC at the suitable points will increase transfer capability, maintain voltage profile, reduce
voltage fluctuation and enhance voltage stability. As well, the SVC will help suppress the power
oscillations via voltage amplitude modulation.

NR provides Static VAR Compensator (SVC) solution to smoothly adjust reactive power in the
power grid or industrial to achieve the stable voltage profile. It is composed of thyristors, reactors,
capacitor banks and control system. Versatile technologies are integrated in NR’s SVC solution,
including Thyristor-Controlled Reactor (TCR), Thyristor-Switched Capacitor (TSC), Breaker-
Switched Capacitor (BSC) or Fixed Capacitor (FC).
Flexible schemes are designed to meet the specific
project requirement, including TCR and TSC, TCR and
BSC or TCR and FC.

NR's SVC solution adopts innovative valve


technologies, reliable thyristor triggering method,
efficient cooling system and advanced protection &
control system. It has extensively gained a significant
market value by supplying dynamic reactive power
with fast response time and low-cost maintenance
scheme. NR could provide the ‘all-in-one’ solution for
SVC system covering study, design, supply, installation,
training, commissioning & trial operation.

24 read more on www.nrelect.com


Static Synchronous
Compensator (STATCOM)

Modern society consistently relies on electrical power, requiring higher


demands of power stability and power quality. High-power rapid impact loads,
rapid growth of asymmetrical impact loads, e.g. electrified railway, increase in
distributed wind power generation equipment, and connections/disconnections
of large load and inevitable power system faults, are adverse factors which can
lead to considerable reactive disturbances in power system and affect power
stability, power quality and economy of power grid operation. The overcurrent
and overvoltage sequences caused by these disturbances may damage the
associated electrical apparatus.

To obtain a stable voltage conditions, the produced reactive power must be compensated. The most advanced solution to compensate the
reactive power is using high performance Insulated Gate Bipolar Transistor (IGBT) to provide fast and variable reactive power to the grid.
The STATCOM can be considered as an advanced static VAR compensator (Advanced SVC).

NR provides the Static Synchronous Compensator (STATCOM) based on Voltage-Sourced-Converter (VSC) for reactive power regulating
used on flexible AC transmission, renewable energy generation, heavy loads centers and industrial fields. It helps utilities and industrial
customers gain economical benefits through solving voltage unbalance and distortion, restraining system overvoltage, supplying damped
oscillations and improving power factor.

Compared to classical SVC, STATCOM has many advantages as following:

• Faster response
The output of STATCOM range from rated capacitive reactive power to rated inductive reactive power with a very short time delay.

• Better ability of restricting voltage fluctuation


The ratio of restricting voltage fluctuation of STATCOM can reach 5:1 or even higher, while the maximum of typical SVC is only 2:1.

• Wider compensation range


Reactive power generated or absorbed by SVC is influenced by system voltage. A lower system voltage will cause weaker
compensation capability of SVC. In contrast, STATCOM is not affected by system voltage, and thus the compensation capability is not
influenced.

• Better results
STATCOM can compensate reactive power, harmonic and unbalance
of load, while SVC only compensates the reactive power.

• Fewer harmonic
Compared to SVC, STATCOM generates fewer harmonic and also
has active filter function.

• Smaller floor space


STATCOM can provide compensation without using capacitors and
reactors, thereby the floor space of STATCOM is only approximately
50% of that for SVC with the same compensation capability.

read more on www.nrelect.com 25


Solutions for Power Electronics

De-Icer

Heavy ice covering on transmission lines may cause tower collapse, break transmission lines and destroy
power grid integrality, generating serious damages to power system, or even large-scale regional outage.

NR develops the innovative De-Icer system to help customer solve the dangerous problem caused by
serious climate. NR provides the fixed De-Icer and relocatable De-Icer to meet the different applications.
And during the normal state, the De-Icer could be used as SVC to compensate the reactive power in the
power grid. It could be switched into the de-Icing state according to the field requirement.

De-Icer adopts thyristor rectifier converting AC current into DC current and injects the DC current into the
conductors, and then realizes de-icing with the heat produced by DC current crossing the line resistance.
When de-icing a transmission line, the line should be out of service and the 3-phase conductor should be
connected with the De-Icer. At the opposite substation, the 3-phase conductor shall be short-circuited. The
DC current will be injected into the conductor via Phase Selecting Switches (PSS) integrated in De-Icer.
The controller of De-Icer controls the DC current via adjusting triggering angle of thyristor.

26 read more on www.nrelect.com


Fixed Series
Compensation (FSC)

Series compensation uses capacitive reactance connecting the transmission line


in series to change the line impedance. Usually it is used for the long transmission
line with bulk electricity. It can increase the power transfer capability as a result of
raising the transient stability limit, improve the voltage profile of the system, reduce
transmission losses by optimizing the sharing of active power between parallel lines
and reduce the cost of power transmission by making power transfer with fewer
parallel lines and less required shunt compensation.

NR provides the complete series compensation solution consisting of capacitor


bank, MOV, spark gap, damping reactor, bypass breaker and insulation platform. As
well, NR supplies the complete protection and control system and HMI management
software for the series compensation. In NR’s series compensation, the electronic
CT with merging unit is integrated providing the current measurement for protection
and control system. The redundant scheme is adopted in merging unit, protection
and control system. NR provides the ‘all-in-one’ solution for series compensation
covering design, supply, installation, training and commissioning. Appropriate design
and product will be selected according to the specific project.

read more on www.nrelect.com 27


Renewable Energy
Interconnection

To protect our environment, human beings should put more emphasis on the renewable energy. Compared to traditional
energy, renewable energy comes from natural resources such as sunlight, wind and geothermal heat, which are naturally
replenished and has minimum impact on environment. Nowadays renewable power generators are spreading across
many countries, providing a significant share of electricity in some areas. NR provides the innovative technologies for the
grid interconnection of renewable energy, including wind energy converter and photovoltaic (PV) inverter.

In solar power generation, power output of photovoltaic arrays


is direct current (DC), NR supplies the PV inverter solution
converting the direct current (DC) into alternative current (AC) and
connecting the solar energy into the power grid. It consists of DC
junction, advanced IGBT controlled converter, AC junction, step-
up transformer and protection & control system. NR also provides
the complete solution to solar generation, including the PV arrays,
DC combiner, DC-AC inverter, AC step-up transformer and SCADA
system of solar generation farm.

In wind power generation, the power output of a turbine is a function


of the cube of the wind speed, thus when wind speed increases or
decreases, the power output will change accordingly. To interconnect
wind energy into power grid, the double-fed scheme is designed. NR
is capable of providing the converter to over-compensate or under-
compensate the power output of wind turbine. The compensated
power output is complying with the grid interconnection.

28 read more on www.nrelect.com


Static Frequency
Converter (SFC)

Static Frequency Converter (SFC) could be used for the starting


and speed control of large capacity synchronous machine
(generator/motor) to improve efficiency and reduce cost.
Generally it is suitable for pumped storage power plant, gas
turbine power plant and some industrial enterprises.

NR provides the advanced SFC products for the power plant


and industrial customers. SFC injects the variable-frequency
current into the stator winding of the synchronous machine to
produce a varying magnetic flux. Simultaneously, the machine
excitation system will inject the exciting current into the rotor
winding, which will produce another magnetic flux. The SFC
can control the rotation speed of the stator magnetic flux by
changing the frequency of injecting current, and make the stator Generator
magnetic flux rotates faster than the rotor magnetic flux. Then
the rotor is driven to rotate and the machine will start until the
Excitation System
pre-set speed is reached. The SFC is composed of rectifier,
inverter and controller. It could detect the initial position of rotor
without any external sensor. And it provides diverse control Excitation system is an important part of generator that is used

mode, including pulse mode control for low frequency, load to inject the exciting current into rotor to estabilish the magnetic

commutation control for high frequency and excitation current field. The excitation system need to maintain the generator

control. voltage level and is required to act on power system static and
transient conditions.

NR provides microprocessor-based excitation system to


improve generator performance and reduce maintenance
costs. It offers the comprehensive control strategies for different
applications, such as power system stabilizer, optimum control
or adaptive control, etc. It also can be customized to meet the
various specifications of specific project. The current rating
is available from 100A up to 7000A and the voltage rating is
available from 100V up to 700V.

NR’s excitation system consists of numerical excitation


regulation system, thyristor rectifier, diode valve rectifier, de-
excitation equipment and auxilary cabinets. According to the
different requirements of each excitation mode, the above
equipments can be flexibly tailored to combine the compatible
solution.

read more on www.nrelect.com 29


A high-voltage, direct current (HVDC) electric power transmission system
may be less expensive and suffer lower electrical losses for long-distance
transmission. In addition, HVDC avoids the heavy currents required by the
cable capacitance for submarin power cables. HVDC also enables power
transmission between asynchronous AC power grids, and can supply power
to urban heavy load center.

Solutions for HVDC & VSC-HVDC

Modern HVDC power transmission asks for high efficient solution featuring
true reliability and flexibility. For this reason, NR is continuously improving
the solution to HVDC control and protection based on years’ of practical
experiences and the most leading-edge technologies. The outstanding
solution includes the control and protection for conventional HVDC
transmission through overhead lines or submarine cables, back-to-back
HVDC transmission and Voltage Source Converter (VSC) based HVDC
transmission.

The conventional HVDC transmission


technology is used for long distance bulk
power transmission through overhead
lines or submarine cables. It is also used
in asynchronous interconnection to AC
networks. NR’s solution to conventional
HVDC transmission focuses on the control
& protection system and DC electronic

Figure 1. Bulk electricity transmission over long distance lines transformer. The control and protection system
is built in redundant structure to ensure the
operation of HVDC system is immune to any
single failure.

Figure 2. Interconnection to AC grids Figure 3. Submarine or underground cables

30 read more on www.nrelect.com


Conventional HVDC
Transmission

The conventional HVDC transmission technology is


used for long distance bulk power transmission through
overhead lines or submarine cables. It is also used in
asynchronous interconnection to AC networks. NR’s
solution to conventional HVDC transmission focuses
on the control & protection system and DC electronic
transformer. The control and protection system is built
in redundant structure to ensure the operation of HVDC
system is immune to any single failure.

VSC-Based HVDC

VSC-based HVDC is a newly developed technology relying on


the self commutated voltage source converter with pulse width
modulation (PWM). It can be used in offshore power transmission,
urban load center infeed and asynchronous grid interconnection.
NR provides innovative solution to VSC-based HVDC transmission
covering control and protection system, DC electronic transformer
and converting valve banks.

DC Electronic CT/VT

Today, HVDC transmission requires high reliable and


efficient equipments to facilitate large capacity power
delivery via long distance lines. Conventional CTs/VTs
has saturation and ferromagnetic resonance problems
that can not keep in step with the rapid development
of HVDC transmission. NR’s DC electronic CT/VT is
applicable to HVDC converter station to measure the DC
current/voltage.

read more on www.nrelect.com 31


For many years, NR is dedicated to providing cost-effective
and high efficient engineering and procurement services and
delivers complete turnkey solutions to customers worldwide.
We can accommodate clients’ preferences for equipment and
design details, and supply them with tailored innovative system
solutions to facilitate and achieve reliable, well-controlled and
economical commercial operation.

Engineering Services

Consulting Service
NR's experienced engineering service teams provide a wealth of telecome consulting and on-site
commissioning for end users all over the world. Customers also can contact NR by hotline or by visiting
official website. NR is always dedicated in training professional engineers and technicians to serve
customers better. We believe that their abundant on-site experiences and expert skills will help users to
solve any emergencies and potential problems.

The dedicated services group offers a wide range of professional consultancy services to customers,
including:

• Power stability study

• Data migration from legacy systems

• On-site commissioning

• Solution and product customization to meet the needs of customer-specific requirements

• Software maintenance

Testing and Engineering Commissioning


NR has groups of qualified testing engineers and field commissioning engineers to accomplish different
kinds of factory tests and assist customers in field commissioning.

32 read more on www.nrelect.com


To ensure the performance and quality, NR has built up complete test laboratories to perform factory acceptance
tests, including HVAC analog simulation test, HVAC digital simulation test, HVDC analog test, HVDC digital test
and combined HVDC & HVAC analog test. NR also facilitated its EMC and type test laboratory and a IEC61850
level B testing laboratory used for device compatibility test. Based on specific requirement for difference
projects, our testing engineers can also complete site acceptance tests with external testers.

NR's regional engineering teams are always working in close cooperation with end users to reduce
commissioning time and cost. This service enables customers to work with our factory-trained technical staffs
on-site to support testing and commissioning efforts and provide hands-on training for your personnel.

Engineering Design
NR engineers design protection and automation scheme for transmission, distribution and generation systems,
and offer unique engineering design on power quality control and system study. The service includes system
settings calculation, complete design and drawing packages and Engineering studies. It enables NR to
promote awareness of detailed system situations of each specific case and to customize system solutions to fit
customers' demands.

The engineering design on power quality focuses on stabilizing weak systems and improving dynamic voltage
control in industrial system. NR's professional engineers will help users to perform system analysis and
valve design. Engineering design on system study is an essential step of power stability control. NR's expert
engineers are involved in the system analysis including studies on system structure, power flows, generation
and consumption, ect., to draw up the offline tactic table for power stability control.

read more on www.nrelect.com 33


To keep pace with the rapid developed technology and product
innovation, NR is committed to providing customers with the
numerous and comprehensive training courses throughout the
year as well as on-demand training at your facility. The training
is a combination of tutoring, factory training and "on-the-job"
training. This is to guarantee the sufficient competence level for
each task.

NR Training Program

NR Training Center
NR has founded a training center with the samples of all products to provide professional training
for domestic and oversea customers. At NR's advanced training center, we offer regularly scheduled
courses containing theoretical courses and hands-on interactions using relays & meters, relay test tools,
automation softwares, communication equipments and personal computers.

The key to the successful training program is qualified and expert instructors. At NR training center, a
group of well trained instructors with years of practical experience in the protection industry is dedicated
to bringing high quality technical topics in different languages, including English, Russan, French and
Spainish.

34 read more on www.nrelect.com


NR insists to keep the class sizes small so instructors can interact with each trainee. Trainees
receive theoretical course manuals and detailed lab exercises guidelines to ensure they can apply
this knowledge in their workplace. Debugging tools such as Omicron and HMI software are provided
to perform the static electrical test for further understanding. Trainees can manipulate and test the
protection and automation devices in laboratories to gain operating experiences.

On-site Training
To maximize customers' benefits from our training, NR offers the option of conducting training courses
at users' facility. These on-site courses can be tailored based on the specific engineering project and
requirements. All the necessary testers and literature will be provided on-site for operation practice.

read more on www.nrelect.com 35


PROTECTION & CONTROL
Transmission Line Protection
Function Index

RCS-902
PCS-902

RCS-931

RCS-901

RCS-941

RCS-943

RCS-922

RCS-924

RCS-925
PCS-931

PCS-924
Functional
Function
Code

Pilot DPFC directional comparison protection 85 √


Pilot distance protection 85 √ √ √
Pilot directional earth fault protection DEF √ √ √ √
Phase current differential protection 87P √ √ √ √ √ √
Zero sequence current differential protection 87G √ √ √
DPFC current differential protection 87D √ √
DPFC distance protection 21D √ √ √ √ √
Phase-to-phase distance protection 21P √ √ √ √ √ √ √
Phase-to-ground distance protection 21G √ √ √ √ √ √ √
Phase directional overcurrent protection 67P √ √ √ √ √ √ √
Phase overcurrent protection 50P/51P √ √ √ √ √ √ √ √ √ √
Zero sequence directional overcurrent protection 67N √ √ √ √ √ √ √
Zero sequence overcurrent protection 50N/51N √ √ √ √ √ √ √
Breaker failure protection for one and two breakers 50BF √ √ √ √
Stub Protection 50S √ √ √ √
Voltage control element for overcurrent √ √ √ √ √
Over-current protection during VT failure 51P VT √ √ √ √ √ √ √
Zero sequence overcurrent during VT failure 51N VT √ √ √ √ √ √ √
Over-voltage protection 59 √ √ √ √ √ √ √
Under-vlotage protection 27 √ √ √ √ √ √
Thermal overload element 49 √ √ √ √ √ √ √
Switch-on-to-fault logic SOTF √ √ √ √ √
Under/Over frequency protection 81 √ √ √ √ √ √
Broken conductor protection 46BC √ √
Dead zone protection √ √ √
Local supervision of DTT √
Fault Locator FL √ √ √ √ √ √ √
Synchronism check 25 √ √ √ √ √ √ √
Auto-reclosing 79 √ √ √ √ √ √ √
Power swing blocking 68 √ √ √ √ √ √ √
Out-of-step tripping 78 √ √
CT failure supervision CTS √ √ √ √ √ √ √ √ √ √
VT failure supervision VTS √ √ √ √ √ √ √ √
Configurable I/O and LED √ √ √
Programmable logic √ √ √
Circuit breaker monitoring √ √ √ √ √ √ √
GPS clock synchronization √ √ √ √ √ √ √ √ √
Fault Recorder √ √ √ √ √ √ √ √ √
IEC61850-8-1 MMS & GOOSE for station bus √ √ √ √ √ √ √ √ √
IEC61850-9-2 SV & IEC61850-8-1 GOOSE for process bus √ √ √
IEC60870-5-103 √ √ √ √ √ √ √ √ √ √ √
DNP 3.0 LAN √ √ √

36 read more on www.nrelect.com


PCS-902
Line Distance Relay

The PCS-902 relay provides numerical line protection


with pilot distance protection, stepped distance protection,
current protection, voltage protection, single and/or three
pole tripping and auto-reclosing functions. As a full-scheme
device, it integrates frequency protection, breaker failure
Functions protection and stub protection. The PCS-902 introduces an
extensive functional library, programmable LED, programable
Protection and Control logic and configurable I/O, intended for applications on
overhead lines and underground cables of all voltage levels,
• Pilot distance protection. (85/21) including series compensated lines, double-circuit lines,
It integrates independent distance zone with (PUTT, POTT, heavily loaded lines, weak infeed (WI), short lines and
Blocking, DTT & Zone Extension). extremely long lines. The PCS-902 adopts a wide range of
innovative patented technologies, such as DPFC (Deviation
• Pilot directional earth-fault protection. (DEF) Power Frequency Component) distance protection and
The relay includes directional zero sequence comparison unique power swing blocking logic, to guarantee its accurate
element for earth fault. and reliable operation.

• DPFC distance protection. (21D) Mho and quadrilateral characteristics are provided for
Innovative Deviation of Power Frequency Component both phase and ground distance protections. It provides
distance protection can quickly clear faults and is immune to the interfaces for station bus and process bus respectively
the load current, weak-infeed and power swing. and supports IEC 61850-8-1 MMS, GOOSE, IEC 61850-9-
2 Sampling Value. It provides the RJ-45 faceplate port for
• Four zones of phase-to-phase distance protection. (21P) testing and setting to make commissioning and maintenance
Four zones of phase-to-phase distance protection integrates easier.
the memorized positive sequence voltage polarization,
direction characteristic, load blinder and unique low-voltage
distance element. The fourth zone can be set as the reverse
directional protection.
Overcurrent protection can be supervised by voltage element
and directional element. IDMT curves complied with IEC and
• Four zones of phase-to-ground distance protection. (21G)
ANSI standard are available for selection.
Four zones of phase-to-ground distance protection integrates
the memorized positive sequence voltage polarization,
• Four stages of directional zero sequence overcurrent
reactance characteristic, direction characteristic, load blinder
protection. (67N, 50/51N)
and unique low-voltage distance element. The fourth zone is
Zero sequence overcurrent protection can be supervised
the reverse directional protection.
by voltage element and directional element. IDMT curves
complied with IEC and ANSI standard are present for
• Four stages of directional phase overcurrent protection. (67P,
selection.
50/51P)

• Breaker failure protection for one or two breakers (50BF)


Breaker failure protection can be applied to one breaker and
two breakers applications.

• Two stages of under voltage protection and two stages of


overvoltage protection (27/59)
Under/over phase voltage protection and negative/zero
sequence overvoltage protection are provided.

• Four stages of underfrequency protection and four stages of


over frequency protection. (81)
Frequency is calculated reference to the positive sequence
voltage. The protection can be supervised by the df/dt
element and the undervoltage element.

read more on www.nrelect.com 37


• Stub protection for T-Zone in a 1½ breaker arrangements. • VT failure supervision.
(50S) • Self diagnostic.
Stub protection is introduced to protect T-zone in a one-and-
• Auxiliary power supervision.
a-half breaker arrangement or a ring breaker arrangement.
• Event recorder including 1024 disturbance records, 1024
• Time phase overcurrent protection during VT failure. (51P binary events, 1024 supervision events and 1024 operating
VT) logs.
Time phase overcurrent protection will be enabled if the • Counter of circuit breaker operation (single-pole tripping,
phase-to-phase distance is blocked by VT failure. three-pole tripping and reclosing).
• Disturbance recorder including 64 disturbance records
• Time zero sequence overcurrent protection during VT failure. with waveforms (The file format of disturbance recorder is
(51N VT) compatible with international COMTRADE file.)
Time zero sequence overcurrent protection will be enabled
if the phase-to-ground distance protection is blocked by VT
failure. Communications

• Pilot communication schemes (PUTT, POTT, Blocking, DTT,


• Switch-onto-fault (SOTF) logic.
WI).
Switch-onto-fault logic is used to clear fault during manually-
closing and auto-reclosing. • Two 10Base-T/100Base-TX (RJ45) ports and two optional
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
• Unique power swing blocking logic. (68) non-time-critical message, IEC 60870-5-103 over TCP/IP or
The power swing blocking logic can prevent mal-operation DNP 3.0.
during external fault in power swing and clear the internal • Two RS-485 rear ports with IEC 60870-5-103.
fault quickly in power swing. • Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling
Value and GOOSE for time-critical message
• Out-of-step tripping (78)
• One RS-485 rear port for clock synchronization
The out-of-step status is detected in the relay and it can be
used to trip the transmission line. • One RS-232 rear port for printer
• One RJ45 front port for testing and setting
• Broken conductor protection (46BC) • Clock synchronization via Pulse-Per-Second, IRIG-B and
The ratio of negative to positive phase sequence current (Ι2/ SNTP
Ι1) is adopted to detect the broken conduct.

• Dead zone protection (50DZ)


It is provided to clear the dead zone fault between CT and Features
breaker.

• Thermal overload protection. (49) • The typical pickup time is 10 ms for a close-in fault, 15 ms
The output of thermal overload protection can be set to for a fault in the middle of a line, 25 ms for a remote fault.
tripping or alarm. • The relay is based on NR’s well established and proven
UAPC hardware platform with multi-processor architecture.
• Synchronism check. (25) The multi CPU technology supports parallel operating
Synchronism check and dead bus or dead line check are simultaneously.
both provided for auto-reclosing.
• The binary output can be used to initiate the power line
• Auto-reclosing (single and/or three-pole for one or two carrier transceiver or other signal channel, and the optical
breakers). (79) fiber is optional instead of carriers to realize the pilot
Single/three pole auto-reclosing is applicable to one or two scheme.
breakers. Priority logic is integrated for use on one-and-a- • The sensitive DPFC distance protection is integrated to
half breaker arrangement and ring breaker arrangement. target on the quick clearance of internal fault without being
affected by power swing.
• Voltage and current drift auto adjustment.
The relay continually and automatically traces the voltage • Phase-ground distance protection is provided with zero-
and current drifts and adjusts the zero point to the normal sequence compensation.
value. • The patented adaptive floating threshold is insensitive to
system imbalance and disturbance. The measuring element
• Frequency tracking. can achieve high security and high speed simultaneously.
Frequency tracking is provided to accommodate the
frequency shift in power system. • The unique built-in power swing blocking logic can properly
supervise the distance protection during a power swing. The
power swing blocking logic can prevent mal-operation for
Monitoring and Metering an external fault and quickly clear the internal fault during a
• CT failure supervision. power swing.

Read more on the web


38 read more on www.nrelect.com www.nrelect.com
• Up to four shots single and/or three pole auto-reclosing with • Users can select either Mho or quadrilateral characteristics
synchro-check and dead line/bus check are provided for for distance protection. The load blinder function is also
multi-breaker configuration. The priority logic of multi-breaker integrated.
auto-reclosing is integrated.
• The independent phase selection element can select the
• The relay is insensitive to the power source change and can faulty phase and make a phase trip correctly.
be applied to the weak infeed condition.
• The two independent data acquisition paths can prevent any
• Instantaneous, definite time and inverse time (IDMT) undesired trip caused by component failure. One works as a
characteristics are available in phase overcurrent protection fault detector and the other is designed for protection and its
and the zero sequence overcurrent protection which can logic. Tripping outputs are supervised by the fault detector to
be controlled by directional protection and/or under voltage prevent mal-operation.
protection through logic setting.
• The connector type is optional, one is the plug in/out terminal
• Independent distance protection is designed for pilot scheme connector and the other is the screw terminal connector. The
to realize PUTT, POTT, Blocking and DTT application. unique plug in/out terminal connectors are used to connect
Additional three zones of forward distance protection and the rear panel to the terminal blocks on the rack or cabinet,
one zone of reverse distance protection are provided. making on-site commissioning and replacement much easier
than using traditional screw terminals.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V

Read more on the web


www.nrelect.com read more on www.nrelect.com 39
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class: IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%,
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

Read more on the web


40 read more on www.nrelect.com www.nrelect.com
- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 41
RCS-902
Line Distance Relay

The RCS-902 is used as the main and back-up protection


for transmission lines with pilot distance element, stepped
distance elements, overcurrent elements, single-pole trip,
three-pole trip and auto-reclosing functions. The integrated
voltage protection, frequency protection, breaker failure
protection and stub protection upgrades the protection. The
RCS-902 is intended for application on overhead lines and
underground cables of all voltage levels, including series
compensated lines, double-circuit lines, weak infeed (WI),
short lines and extremely long lines. It fully supports IEC
61850 communication.

• Thermal overload protection (49)


• Overload alarm function.
• Synchronism check (25)
• Auto-reclosing (single-pole and/or three-pole (79)
• Voltage and current drift auto adjustment

Functions Monitoring and Metering


Protection and Control • CT failure supervision

• Pilot directional distance element. (PUTT, POTT, Blocking • VT failure supervision


and Direct Transfer Tripping) (85) • Tripping circuit supervision
• Pilot directional earth fault protection. (DEF) • Self diagnostic test
• DPFC distance protection (21D) • Fault Recorder
• Four zones of phase-to-phase distance protection (21P), • Fault Locator
• Four zones of phase-to-ground distance protection (21G) • Total 1280 SOE, including tripping, alarm, binary input
• Four stages of directional phase overcurrent protection (67P, change and human operation reports.
50/51P) • High resolution oscillography of last 24 oscillograms.
• Four stages of directional zero sequence overcurrent (Compatible with COMTRADE format)
protection (67N, 50/51N)
• Breaker failure protection (50BF) Communications
• Two stages of under voltage protection and two stages of
• Pilot communication schemes (PUTT, POTT, Blocking, DTT,
over voltage element (27/59)
WI) with fiber, carrier or other channels.
• Four stages of frequency protection (81)
• 2 optional Ethernet ports with IEC 61850 protocol
• Stub protection for T-Zone in 3/2 breaker and ring breaker
• 2 RS-485 communication rear ports with IEC 60870-5-103
arrangements. (50S)
protocol
• Time overcurrent protection during VT failure (51P VT)
• 1 RS-485 communication rear ports for clock synchronization
• Time zero sequence overcurrent protection during VT failure
• 1 RS-232 communication rear ports or RS-485 for printer
(51N VT)
• 1 RS-232 communication faceplate port for testing and
• Switch-onto-fault (SOTF) logic
setting
• Power swing blocking (68)
• GPS clock synchronization.

Read more on the web


42 read more on www.nrelect.com www.nrelect.com
Features
• The typical pickup time is 10 ms for a close-in fault, 15 ms Additional three zones of forward distance element and one
for a fault in the middle of the line, 25 ms for a remote fault. zone of backward distance element are provided.
• The unique DPFC distance element is integrated in the • The relay provides two principles for user selection with Mho
relay. It can quickly clear any internal fault. The sensitivity of or quadrangle with Mho characteristics.
the DPFC distance element is very high and the operation
• The relay integrates independent phase selection elements
speed is very fast. It is not affected by power swing.
and can select the faulty phase and make a phase trip
• The patented adaptive floating threshold method is adopted, correctly, even for a high resistance fault.
which is insensitive to system unbalance and disturbance.
• Innovative technology to prevent any undesired trip caused
The measuring element can get both high security and high
by any component failure is adopted. The relay has two
speed simultaneously.
independent data acquisition paths, one for a fault detector
• The built-in unique power swing blocking logic can properly and the other for protection and its logic. Tripping outputs
supervise the distance elements during a power swing. The are supervised by the fault detector to prevent any mal-
power swing blocking logic can keep the relay stable for an operation.
external fault and pickup for any internal fault during a power
• The connector type can be selected as plug in/out terminal
swing.
connector or crimp terminal connector. The unique plug in/
• The relay is insensitive to the power source change and can out terminal connectors from the relay rear panel to the
be applied to the weak infeed condition. terminal blocks on the rack or cabinet makes the on-site
commissioning and replacement much easier than the
• It provides stub current differential protection or overcurrent
traditional screw terminals when you do the commissioning.
protection for one-and-a-half breaker arrangement.
• The relay provides GPS clock synchronization, such
• Instantaneous, definite time and inverse time (IDMT)
as message, second pulse, minute pulse, and IRIG-B
characteristics are all provided for phase overcurrent
synchronization.
protection and zero sequence overcurrent protection which
can be controlled by directional element and/or voltage • The relay is compatible with multiple protocols- IEC61850
element by logic setting. and IEC 60870-5-103. The relay provides networking
interface such as RS485, RS232 and Ethernet port.
• Independent distance element is provided for pilot scheme
to realize PUTT, POTT, Blocking and DTT application.

Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V

Read more on the web


www.nrelect.com read more on www.nrelect.com 43
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level

Read more on the web


44 read more on www.nrelect.com www.nrelect.com
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

Read more on the web


www.nrelect.com read more on www.nrelect.com 45
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


46 read more on www.nrelect.com www.nrelect.com
PCS-931
Line Differential Relay

The PCS-931 relay provides a full-scheme numerical


line protection with phase-segregated current differential
protection, zero sequence current differential protection,
stepped distance protection, current protection and voltage
protection with single and/or three pole tripping and auto-
reclosing. It introduces an extensive functional library,
programmable logic and configurable I/O, intending for
Optionally, the PCS-931 incorporates two sets of CT input for the use on overhead lines and underground cables of all
dual-breaker application. The dual-breaker failure protection, Functional Block
voltage levels, Diagram
including series compensated lines, double-
dual-breaker auto-reclosing and stub protection are integrated circuit lines, three-terminal lines, heavily loaded lines, weak
for one-and-a-half breaker and ring breaker arrangements. To infeed (WI), short lines and extremely long lines. An extra
enhance the accuracy of data sampling, the frequency-tracking communication port is optional to provide dual protection
function is used to trace the real-time current/voltage value. The channels for three-terminal application and redundant
PCS-931 adopts the advanced UAPC multi-processor platform application. The PCS-931 adopts a wide range of innovative
which is fully complied with IEC 61850. It provides the interfaces patented technologies, such as DPFC (Deviation Power
for station bus and process bus respectively and supports IEC Frequency Component) distance protection and unique
61850-8-1 MMS, GOOSE, IEC 61850-9-2 Sampling Value. And power swing blocking logic, to guarantee accurate and
it provides the RJ-45 front port for testing and setting to make reliable operations.
commissioning and maintenance easier.

Functions Deviation of Power Frequency Component (DPFC) differen-


tial current protection is sensitive to high resistance fault and
Protection and Control is immune to load current variation.

• Phase-segregated current differential protection. (87) • DPFC distance protection. (21D)


Dynamic charging current compensation technology and CT Innovative Deviation of Power Frequency Component(DPFC)
saturation detection are integrated to realize a combination distance protection can quickly clear faults.
of both sensitivity and security of current differential protec-
tion. • Four zones of phase-to-phase distance protection. (21P)
Four zones of phase-to-phase distance protection integrates
• Zero sequence current differential protection. (87) the memorized positive sequence voltage polarization, di-
Zero sequence current differential protection integrates the rection characteristic, load blinder and unique low-voltage
dynamic charging current compensation technology and CT distance element. The fourth zone is the reversal directional
saturation detection, aiming at quickly detecting and clearing protection. Mho and quadrilateral characteristics are pro-
the ground fault. vided for selection.

• DPFC differential protection. (87) • Four zones of phase-to-ground distance protection. (21G)
Four zones of phase-to-ground distance protection inte-
grates the memorized positive sequence voltage polariza-
tion, reactance characteristic, direction characteristic, load
blinder and unique low-voltage distance element. The fourth
zone is the reversal directional protection. Mho and quadri-
lateral characteristics are provided for selection.

• Four stages of directional phase overcurrent protection. (67P,


50/51P)
Overcurrent protection can be supervised by voltage ele-
ment and directional element. IDMT curves complied with
IEC and ANSI standard are present for selection.

• Four stages of directional zero sequence overcurrent protec-


tion. (67N, 50/51N)

Read more on the web


www.nrelect.com read more on www.nrelect.com 47
Overcurrent protection can be supervised by voltage ele- Single/three pole auto-reclosing is applicable to one or two
ment and directional element. IDMT curves complied with breakers. Priority logic is integrated for use on one-and-a-
IEC and ANSI standard are present for selection. half breaker application and ring breaker application.

• Breaker failure protection for one or two breakers (50BF) • Voltage and current drift auto adjustment.
Breaker failure protection can be applied to one breaker and The relay continually and automatically traces the voltage
two breakers. and current drifts and adjusts the zero point to the normal
value.
• Two stages of under voltage protection and two stages of
over voltage protection (27/59) • Frequency tracking.
Under/over phase voltage protection and under/over (positive Frequency tracking is provided to accommodate the fre-
sequence, negative sequence or zero sequence) voltage quency shift in power system.
protection are provided.

Monitoring and Metering


• Four stages of underfrequency protection and four stages of
over frequency protection (81) • CT failure supervision.
Frequency is calculated reference to the positive sequence
• VT failure supervision.
voltage. The protection can be supervised by the df/dt ele-
ment and the undervoltage element. • Tripping circuit supervision.
• Self diagnostic.
• Stub protection for T-Zone in 3/2 breaker arrangement. (50S) • Auxiliary power supervision.
Stub protection is introduced to protect T-zone in a one-and-
• Event recorder including 1024 disturbance records, 1024
a-half breaker scheme or a ring breaker scheme.
binary events, 1024 supervision events and 1024 operating
logs.
• Time phase overcurrent protection during VT failure. (51P
VT) • Counter of circuit breaker operation (single-pole tripping,
Time phase overcurrent protection will be enabled if phase- three-pole tripping and reclosing).
to-phase distance protection is blocked by VT failure. • Disturbance recorder including 64 disturbance records
with waveforms (The file format of disturbance recorder is
• Time zero sequence overcurrent protection during VT failure. compatible with international COMTRADE file.)
(51N VT)
Time zero sequence overcurrent protection will be enabled if
Communications
phase-to-ground distance protection is blocked by VT failure.
• Single- or double- pilot channel based on dedicated optical
• Broken conductor protection (46BC) fiber or multiplex channel(C37.94 or G.703 with external
The ratio of negative to positive phase sequence current (Ι2/ converter).
Ι1) is adopted to detect the broken conduct. • Two 10Base-T/100Base-TX (RJ45) ports and two optional
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
• Switch-onto-fault (SOTF) logic. non-time-critical message, IEC 60870-5-103 over TCP/IP or
Switch-onto-fault logic is used to clear fault during manually- DNP 3.0.
closing and auto-reclosing.
• Two RS-485 rear ports with IEC 60870-5-103.

• Out-of-step tripping (78) • Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling
The out-of-step status is detected in the relay and it can be Value and GOOSE for time-critical message
used to trip the transmission line. • One RS-485 rear port for clock synchronization
• One RS-232 rear port for printer
• Unique power swing blocking logic. (68)
• One faceplate RJ45 port for testing and setting
The power swing blocking logic can prevent mal-operation
during external fault a power swing and clear the internal • Clock synchronization via Pulse-Per-Second, IRIG-B and
fault in power swing. SNTP

• Thermal overload protection. (49)


The output of thermal overload protection can be set to trip-
Features
ping or alarm.
• The PCS-931 can quickly clear the internal fault for the
whole line and the typical operation time is 10ms for a close-
• Dead zone protection (50DZ)
in fault and 25ms for a remote fault.
It is provided to clear the dead zone fault between CT and
breaker. • The relay is based on NR’s well established and proven
• Synchronism check. (25) UAPC hardware platform with multi-processor architecture.
Synchronism check and dead bus or dead line check are The multi CPU technology supports parallel operation
both provided for auto-reclosing. simultaneously.
• The PCS-931 adopts high restraint factor and self-adaptive
• Auto-reclosing (single and/or three-pole for one or two
floating restraint threshold to realize both high reliability and
breakers). (79)
sensitivity even in the CT saturation.
Read more on the web
48 read more on www.nrelect.com www.nrelect.com
• Data exchange between PCS-931 in different substations auto-reclosing is integrated.
can be achieved by dedicated optical fiber or G.703/C37.94
• Instantaneous, definite time and inverse time (IDMT)
communication interface. Error bit statistic and loss of
characteristics are available in phase overcurrent protection
communications detection are supplied to determine the
and the zero sequence overcurrent protection which can
health of communication channel, measure and continuously
be controlled by directional protection and/or under voltage
compensate channel delay.
protection through logic setting.
• The dynamic charging current compensation technology
• Three zones of forward distance element and one zone of
is integrated to acquire accurate differential current for
reverse distance element are provided.
application on long overhead lines or cables.
• Users can select either Mho or quadrangle with Mho
• The CT ratio of different terminals can be regulated by
characteristics for distance protection. The load blinder
setting the relevant configurable coefficients in software.
function is also integrated.
• The PCS-931 can receive/send the tripping commands
• The independent phase selection element can select the
from/to the protection at the opposite terminal via fiber optic
faulty phase and make a phase trip correctly, even for a high
channel.
resistance fault.
• Each zone of phase-ground distance protection is provided
• The two independent data acquisition paths can prevent any
with independent zero-sequence compensation.
undesired trip caused by component failure. One works as a
• The sensitive DPFC distance protection is less affected by fault detector and the other is designed for protection and its
power swing and thus is integrated to target quick clearance logic. Tripping outputs are supervised by the fault detector to
of internal fault. prevent any mal-operation.
• The patented adaptive floating threshold method is • Optional connector type: one is the plug in/out terminal
insensitive to system unbalance and disturbance. The connector and the other is the screw terminal connector. The
measuring element can achieve high security and high unique plug in/out terminal connectors are used to connect
speed simultaneously. the rear panel to the terminal blocks on the rack or cabinet,
making on-site commissioning and replacement much easier
• The unique built-in power swing blocking logic can properly
than using traditional screw terminals.
supervise the distance protection during a power swing. The
power swing blocking logic can prevent mal-operation for • The relay is compatible with IEC 61850-8-1 MMS, GOOSE
an external fault and quickly clear the internal fault during a and IEC 61850-9-2 Sampling Value and provides the
power swing. independent interfaces for station bus and process bus
respectively.
• Up to four shots single and/or three pole auto-reclosing with
synchro-check and dead line/bus check are provided for
multi-breaker configuration. The priority logic of multi-breaker

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Read more on the web


www.nrelect.com read more on www.nrelect.com 49
Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class: IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

Read more on the web


50 read more on www.nrelect.com www.nrelect.com
- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns

Read more on the web


www.nrelect.com read more on www.nrelect.com 51
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


52 read more on www.nrelect.com www.nrelect.com
RCS-931
Line Differential Relay

The RCS-931 relay is an advanced current differential


protection with stepped distance elements and overcurrent
elements intended for main and backup protection for
transmission lines with single-pole trip, three-pole trip
and auto-reclosing schemes. Phase segregated current
differential, zero sequence current differential and DPFC
differential are combined into the unique current differential
element. It also integrates voltage protection, frequency
protection, breaker failure protection and stub protection.
The relay can be used to protect the overhead lines and
underground cables of all voltage levels, including series
compensated lines, double-circuit lines, weak infeed (WI),
short lines and extremely long lines. It is fully compatible with
IEC 61850 communication. RCS-931 line differential relay is
also suitable for two-terminal and three-terminal applications.

• Time overcurrent protection during VT failure. (51P VT)


• Time zero sequence overcurrent protection during VT failure.
(51N VT)
• Switch-onto-fault (SOTF) logic.
• Power swing blocking (68)

Functions • Thermal overload protection. (49)


• Overload alarm function. (Optional)
Protection and Control • Synchronism check. (25)
• Phase current differential protection (87P) • Auto-reclosing (single-pole and/or three-pole). (79)
• Zero sequence current differential protection (87N) • Voltage and current drift auto adjustment.
• DPFC (Deviation of Power Frequency Component) differen-
tial protection (87D) Monitoring and Metering
• Pilot protection including PUTT, POTT, Blocking DTT and
• CT failure detection supervision.
directional earth fault element (DEF) (85) (Optional)
• VT failure detection supervision.
• DPFC distance protection. (21D)
• Tripping circuit supervision.
• Four zones of phase-to-phase distance protection. (21P),
• Self diagnostic.
• Four zones of phase-to-ground distance protection. (21G)
• Fault Recorder.
• Four stages of directional phase overcurrent protection. (67P,
50/51P) • Fault Locator.

• Stages of directional zero sequence overcurrent protection. • Total 1280 SOE, including tripping , alarm, binary input
(67N, 50/51N) change and human operation reports.

• Breaker failure protection. (50BF) • High resolution oscillography of last 24 oscillograms. (Com-
patible with COMTRADE format)
• Two stages of under voltage protection and two stages of
over voltage protection. (27/59)
• Four stages of frequency protection (81)
Communications

• Stub protection for T-Zone in 3/2 breaker and ring breaker • 1 or 2 communication channels with dedicated fiber or multi-
application (50S) plexer fiber for protection

Read more on the web


www.nrelect.com read more on www.nrelect.com 53
• 2 optional Ethernet ports with IEC 61850 protocol • The built-in reliable power swing blocking logic can properly
• 2 RS-485 communication rear ports with IEC 60870-5-103 supervise the distance elements during a power swing. The
protocol power swing blocking logic can make the relay untrip for an
external fault and pickup for an internal fault during a power
• 1 RS-485 communication rear ports for clock synchroniza-
swing.
tion
• 1 RS-232 communication rear ports or RS-485 for printer • Optical fiber data exchange between terminal equipment at
64 kBit/s or 2048kBit/s.
• 1 RS-232 communication faceplate port for testing and set-
ting • The CT ratio of two or three terminals could be different.
• GPS clock synchronization. Different ratio of various CT on each terminal could be regu-
lated by configurable coefficients in software.

• The teleprotection channel could be monitored automatically.


Features Bit error rate could be displayed online. Differential protec-
tion will be blocked during channel failure.
• Quickly clearing any internal fault for the whole line, the time • The relay could receive tripping command from the opposite
is less than 10 ms for faults which is near the busbar, less terminal protection and transmit tripping command to the op-
than 15ms for faults which is in the center of line and less posite terminal protection via a fiber optic channel.
than 25ms for faults which is in the remote end.
• Innovative technology to prevent any undesired trip caused
• The unique DPFC distance element is integrated in the re- by any component failure is adopted. The relay has two
lay. It can quickly clear the internal fault. The sensitivity of independent data acquisition paths, one for a fault detector
the DPFC distance element is very high and the operation and the other for protection and its logic. Tripping outputs
speed is very fast. It is not affected by power swing. are supervised by the fault detector to prevent any mal-
operation.
• The patented adaptive floating threshold method is adopted,
which is insensitive to system unbalance and disturbance. • The connector type can be selected as plug in/out terminal
The measuring element can get both high security and high connector or crimp terminal connector. The unique plug in/
speed simultaneously. out terminal connectors from the relay rear panel to the ter-
minal blocks on the rack or cabinet makes the on-site com-
• The relay provides stub overcurrent protection or overcurrent
missioning and replacement much easier than the traditional
protection for one-and-a-half breaker arrangement.
screw terminals when you do the commissioning.
• Instantaneous, definite time and inverse time (IDMT) char-
• The relay provides GPS clock synchronization, such as sec-
acteristics are all provided for phase overcurrent protection
ond pulse, minute pulse, and IRIG-B synchronization.
and zero sequence overcurrent protection which can be con-
trolled by directional element and/or under voltage element • The relay is compatible with multiple protocols- IEC61850
by logic setting. and IEC 60870-5-103. The RCS-931 provides networking
interface such as RS485, RS232 and Ethernet port.
• The RCS-931 adopts high restraint factor and self-adaptive
floating restraint threshold; it maintains high reliability and
sensitivity even in serious CT saturation cases.

Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In

Read more on the web


54 read more on www.nrelect.com www.nrelect.com
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
RS-485 (EIA) Electrical Transmission distance < 1000m@4800bps
Maximal capacity 32
Twisted Pair Screened twisted pair cable

Read more on the web


www.nrelect.com read more on www.nrelect.com 55
Protocol IEC60870-5-103:1997
RS-485 (EIA) Electrical
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


56 read more on www.nrelect.com www.nrelect.com
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 57
RCS-901
Line Directional Comparison Relay

The RCS-901 relay is a pilot directional protection used as


the main and backup protection for transmission lines with
stepped distance elements, overcurrent elements, single-pole
trip, three-pole trip and auto-reclosing functions. The relay
can be used to protect the overhead lines and underground
cables of all voltage levels, including series compensated
lines, double-circuit lines, weak infeed (WI), short lines,
extremely long lines, three-terminal lines. It fully supports IEC
61850 communication protocol.

Monitoring and Metering

• CT failure supervision.
• VT failure supervision.
• Synchro-check voltage failure supervision.
• Tripping circuit supervision.
• Fault Recorder.
• Fault Locator.
• 64 tripping reports, 64 alarm reports and 64 binary input
status change reports.
• High resolution oscillography of last 24 oscillograms.
Functions (Compatible with COMTRADE format)

Communications
• Pilot DPFC (Deviation Power Frequency Variation
Component) directional comparison line protection. (85) • Pilot communication schemes (PUTT, POTT, WI) with fiber,
• Pilot zero sequence directional comparison protection. (DEF) carrier or other channels.

• DPFC distance protection. (21D) • 2 optional Ethernet ports with IEC 61850 or IEC 60870-5-
103 over TCP/IP
• Phase-to-phase distance protection. (21P)
• 2 RS-485 communication rear ports conform to IEC 60870-
• Phase-to-ground distance protection. (21G)
5-103 protocol
• Directional phase overcurrent protection. (67P)
• 1 RS-485 communication rear ports for clock synchronization
• Phase overcurrent protection. (50/51P)
• 1 RS-232 communication rear ports or RS-485 for printer
• Directional zero sequence overcurrent protection. (67N)
• 1 RS-232 communication faceplate port for testing and
• Zero sequence overcurrent protection. (50/51N) setting
• Under/Over voltage protection. (27/59) • GPS clock.
• Time overcurrent protection during VT failure. (51P VT)
• Time zero sequence protection during VT failure. (51N VT)
• Switch-onto-fault (SOTF) logic. Features
• Power swing blocking (68)
• The typical operating time is 10 ms for a close-in fault, 15 ms
• Fault detection element under pole discrepancy condition
for a fault in the middle of the line, 25 ms for a remote fault.
• Overload alarm function.
• The protection principles of DPFC directional comparison
• Synchronism check. (25)
element and DPFC distance element are applied in the relay.
• Auto-reclosing (single-pole and three-pole). (79) It can significantly reduce the pickup time and clear the fault
• Voltage and current drift auto adjustment. fast. The DPFC directional pilot scheme is sensitive which
• Self diagnostict. makes the system reliable. The system adopting this pilot

Read more on the web


58 read more on www.nrelect.com www.nrelect.com
scheme is not affected by series compensated capacitors and • The built-in reliable power swing blocking logic can properly
doesn’t need a power swing blocking logic. supervise the distance elements during a power swing. The
power swing blocking logic can make the relay untrip for an
• The patented adaptive floating threshold method is adopted,
external fault and pickup for an internal fault during a power
which is insensitive to system unbalance and disturbance. The
swing.
measuring element can get both high security and high speed
simultaneously. • The relay can select the faulty phase and make a phase trip
correctly, even for a high resistance fault.
• The built-in reliable power swing blocking logic can properly
supervise the distance elements during a power swing. The • Innovative technology to prevent any undesired trip caused
power swing blocking logic can make the relay untrip for an by any component failure is adopted. The relay has two
external fault and pickup for an internal fault during a power independent data acquisition paths, one for a fault detector
swing. and the other for protection and its logic. Tripping outputs are
supervised by the fault detector to prevent a mal-operation.
• Definite time and inverse time characteristics are both provided
of zero sequence overcurrent protection. • The relay provides GPS clock synchronization, including
message, second pulse, minute pulse, and IRIG-B
• The relay can receive and transmit the remote tripping
synchronization.
commands from and to the opposite terminal via channel.
• The relay is compatible with multiple protocols- IEC61850
• The relay can select the faulty phase and make a phase trip
and IEC 60870-5-103. The RCS-901 provides networking
correctly, even for a high resistance fault.
interface such as RS485, RS232 and Ethernet port.

Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Read more on the web


www.nrelect.com read more on www.nrelect.com 59
Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class: IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Ethernet Safety level Isolation to ELV level
Port number 2
Connector type SC
Transmission Rate 100Mbits/s
Optical(optional)
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical Fiber Type Multi-mode or single-mode

Read more on the web


60 read more on www.nrelect.com www.nrelect.com
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Ethernet Optical(optional) Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 61
RCS-941
Line Distance Relay

The RCS-941 relay is a digital distance protection used as


the main and back-up protection for overhead transmission
lines and ungrounded cables, including phase-phase and
phase-ground distance element, overcurrent element with
three-pole tripping and auto-reclosing. Pilot scheme can be
comprised in the relay. It is fully compatible with IEC 61850
communication.

Monitoring and Metering

• Voltage auto-switching for double busbar application


• Circuit breaker monitoring.
• CT failure detection logic.
• VT failure detection logic.
• Tripping circuit supervision.
• Voltage and current drift auto adjustment.
• Self diagnostic.
• Fault Recorder.
• Fault Locator.
• GPS clock synchronization.
• 64 tripping reports, 64 alarm reports and 64 binary input sta-
Functions tus change reports.
• High resolution oscillography of last 24 oscillograms (Com-
Protection and Control
patible with international COMTRADE format).
• Optional Pilot distance protection(PUTT, POTT, blocking and
DTT). (85)
Communications
• Optional Pilot zero sequence directional comparison protec-
tion. (DEF) • Pilot communication schemes with fiber, carrier or other
channels.
• Phase-to-phase distance protection. (21P)
• 2 optional Ethernet ports with IEC 61850 protocol.
• Phase-to-ground distance protection. (21G)
• 2 RS-485 communication rear ports with IEC 60870-5-103
• Directional phase overcurrent protection. (67P)
protocol.
• Phase overcurrent protection. (50P, 51P)
• 1 RS-485 communication rear ports for clock synchroniza-
• Directional zero sequence overcurrent protection. (67N)
tion.
• Zero sequence overcurrent protection. (50N, 51N)
• 1 RS-232 communication rear ports or RS-485 for printer.
• Switch-onto-fault (SOTF) logic.
• 1 RS-232 communication faceplate port for testing and set-
• Under frequency protection. (81) ting.
• Under/over voltage protection. (27/59)
• Frequency rate-of-change element. (7F)
• Voltage rate-of-change element. (7V) Features
• Power swing blocking. (68)
• The relay integrates AC voltage auto-switching module. In
• Accelerated tripping for asymmetric faults.
the double-busbar scheme, when the transmission line is
• Accelerated tripping for double circuit faults. switched between the two busbars, the AC voltage inputs of
• Overload alarm function. the relay will be auto-switched according to the actual bus-
• Synchronism check. (25) bar VT based on the states of isolators.

• Auto-reclosing (three-pole). (79)


Read more on the web
62 read more on www.nrelect.com www.nrelect.com
• Unique accelerated trip for double-circuit line and acceler- and the other for protection and its logic. Tripping outputs are
ated trip for asymmetric fault can reduce the tripping time supervised by the fault detector to prevent a mal-operation.
during double-circuit line fault and asymmetric fault. The two
• The connector type can be selected as plug in/out terminal
schemes guarantee a fast clearance time even without pilot
connector or crimp terminal connector. The unique plug in/
protection.
out terminal connectors from the relay rear panel to the ter-
• The built-in reliable power swing blocking logic can properly minal blocks on the rack or cabinet makes the on-site com-
supervise the distance elements during a power swing. The missioning and replacement much easier than the traditional
power swing blocking logic can make the relay untrip for an screw terminals when you do the commissioning.
external fault and pickup for an internal fault during a power
• The relay provides GPS clock synchronization, including
swing.
message, second pulse, minute pulse and software IRIG-B
• The patented adaptive floating threshold method is adopted, synchronization.
which is insensitive to system unbalance and disturbance.
• The format of event report is compatible with international
The measuring element can get both high security and high
COMTRADE file.
speed simultaneously.
• The relay is compatible with multiple protocols- IEC61850
• Innovative technology to prevent any undesired trip caused
and IEC 60870-5-103. It provides networking interface such
by any component failure is adopted. The relay has two
as RS485, RS232 and Ethernet port.
independent data acquisition paths, one for a fault detector

Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms
Binary Outputs
Read more on the web
www.nrelect.com read more on www.nrelect.com 63
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class: IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Ethernet Safety level Isolation to ELV level
Port number 2
Connector type SC
Transmission Rate 100Mbits/s
Optical(optional)
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical Fiber Type Multi-mode or single-mode

Read more on the web


64 read more on www.nrelect.com www.nrelect.com
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Ethernet Optical(optional) Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 65
RCS-943
Line Differential Relay

The RCS-943 relay provides complete set of main and backup


protection for overhead transmission lines and underground
cables of all voltage levels, including current differential element,
stepped distance elements, stepped overcurrent element with
three-pole tripping and auto-reclosing. It is fully compatible with
IEC 61850 communication.

• Auto-switching module for AC voltage


• Circuit breaker monitoring.
• CT failure detection logic.
• VT failure detection logic.
• Tripping circuit supervision.
• Voltage and current drift auto adjustment.
• Self diagnostic.
• GPS clock synchronization.
• Fault Recorder.
• Fault Locator.
• 64 tripping reports, 64 alarm reports and 64 binary input sta-
tus change reports.
• High resolution oscillography of last 24 oscillograms. (Com-
patible with international COMTRADE format).

Communications
Functions
• High-speed optical fiber channel for protection data ex-
Protection and Control changing.

• Phase current differential protection (87P) • 2 optional Ethernet ports with IEC 61850 protocol

• Zero sequence current differential protection (87N) • 2 RS-485 communication rear ports with IEC 60870-5-103
protocol.
• DPFC (Deviation Power Frequency Component) differential
protection (87D) • 1 RS-485 communication rear ports for clock synchroniza-
tion.
• Phase-phase distance protection (21P)
• 1 RS-232 communication rear ports or RS-485 for printer.
• Phase-ground distance protection (21G)
• 1 RS-232 communication faceplate port for testing and set-
• Four-stage directional phase overcurrent protection (67P,
ting.
50P, 51P)
• Four-stage directional zero sequence overcurrent protection
(67N, 50N, 51N)
• Power swing blocking function (68) Features
• Overload alarm function (49)
• Circuit breaker monitoring • The relay integrates AC voltage auto-switching module. In
the double-busbar scheme, when the transmission line is
• Voltage and current drift auto regulation
switched between the two busbars, the AC voltage inputs of
• Synchro-checking (25) the relay will be auto-switched according to the actual bus-
• Auto-reclosing (three-pole) function (79) bar VT based on the states of isolators.
• Monitoring and Metering • The patented adaptive floating threshold method is adopted,
which is insensitive to system unbalance and disturbance.

Read more on the web


66 read more on www.nrelect.com www.nrelect.com
The measuring element can get both high security and high • The relay can receive tripping command from the opposite
speed simultaneously. terminal protection and transmit tripping command to the op-
posite terminal protection via fiber a optic channel.
• The RCS-943 adopts high restraint factor and self-adaptive
floating restraint threshold, it will keep the high reliability and • Innovative technology to prevent any undesired trip caused
sensitivity even in serious CT saturation cases. by any component failure is adopted. The relay has two
independent data acquisition paths, one for a fault detector
• The built-in reliable power swing blocking logic can properly
and the other for protection and its logic. Tripping outputs are
supervise the distance elements during a power swing. The
supervised by the fault detector to prevent a mal-operation.
power swing blocking logic can make the relay untrip for an
external fault and pickup for an internal fault during a power • The connector type can be selected as plug in/out terminal
swing. connector or crimp terminal connector. The unique plug in/
out terminal connectors from the relay rear panel to the ter-
• Optical fiber data exchange between terminal equipment at
minal blocks on the rack or cabinet makes the on-site com-
64 kBit/s or 2048kBit/s.
missioning and replacement much easier than the traditional
• The CT ratio of two or three terminals could be different. Dif- screw terminals when you do the commissioning.
ferent ratios of various CT on each terminal can be regulated
• The relay provides GPS clock synchronization, such as mes-
by configurable coefficients in software.
sage, second pulse, minute pulse, and IRIG-B synchroniza-
• The teleprotection channel could be monitored automatically. tion.
Bit error rate could be displayed online. Differential protec-
• The relay is compatible with multiple protocols- IEC61850
tion will be blocked during channel failure.
and IEC 60870-5-103. It provides networking interface such
as RS485, RS232 and Ethernet port.

Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un

Read more on the web


www.nrelect.com read more on www.nrelect.com 67
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Protection class: IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Ethernet
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Optical(optional) Connector type SC
Transmission Rate 100Mbits/s

Read more on the web


68 read more on www.nrelect.com www.nrelect.com
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Ethernet Optical(optional) Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 69
PCS-924
Stub Differential Relay

The PCS-924 numerical relay provides current differential


protection, sum overcurrent protection and feeder end fault
protection for the T-zone in breaker-and-a-half arrangement
and ring breaker arrangement. It integrates the three groups
of CT input and provides both 3-terminal and 2-terminal
current differential protections for T-zone according to the
binary input of feeder breaker auxiliary contact. The feeder
end fault protection based on the feeder CT is adopted
to avoid the trip of local breakers and send transfer trip
command to the remote end when the feeder isolator is open.
In addition, the overcurrent protection based on the sum of
two breaker CTs is used as the feeder backup protection
or energizing protection. The PCS-924 relay employs the
programmable logic, configurable I/O and definable 3-color
LEDs to provide the flexibility for the specific application.
Frequency tracking is used to minimize the sampling error
due to system frequency fluctuation. The PCS-924 relay
adopts the advanced UAPC multi-processor platform which
is fully complied with IEC 61850. It provides the interfaces
for station bus and process bus respectively and supports
IEC 61850-8-1 MMS, GOOSE, IEC 61850-9-2 Sampling
Value. And it provides the RJ-45 faceplate port for testing and
setting to make commissioning and maintenance easier.

Functions
Protection and Control

• Current differential protection (87S) Monitoring and Measurement


3-terminal and 2-terminal current differential protection can be
automatically switched according to the binary input of feeder • CT circuit supervision (CTS)
isolator status. If the feeder is open by the isolator, the feeder • Self diagnostic.
CT will automatically quit from the current differential protection. • Auxiliary power supervision
• Event recorder including 1024 disturbance records, 1024
• Feeder end fault protection (50FLE)
binary events, 1024 supervision events and 1024 operating
This element will be valid when the feeder isolator is open. Due
logs.
to the fault between isolator and feeder CT, the fault current only
flows through the feeder CT and no fault current passes the two • Disturbance recorder including 64 disturbance records
breaker CTs. Thus the relay will send the transfer trip command with waveforms (The file format of disturbance recorder is
to the remote end and keep the local breakers closed. compatible with international COMTRADE file.).
• Counter of circuit breaker operation (single-pole tripping,
• Sum overcurrent protection (50P) three-pole tripping and reclosing).
The overcurrent protection adopts the sum of phase currents
from two breaker CTs. It can be used as the energizing
Communication
protection or feeder backup protection.
• Two 10Base-T/100Base-TX (RJ45) ports and two optional
• Current drift auto adjustment 100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
The relay continually and automatically traces the current drifts non-time-critical message, IEC 60870-5-103 over TCP/IP or
and adjusts the zero point. DNP 3.0
• Two RS-485 rear ports with IEC 60870-5-103
• Frequency tracking
Frequency tracking is provided to accommodate the frequency • Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling
shift in power system. Value and GOOSE for time-critical message

Read more on the web


70 read more on www.nrelect.com www.nrelect.com
• One RS-485 rear port for clock synchronization • The fault detector element consists of the pickup of differ-
• One RS-232 rear port for printer ential current and the pickup of the sum current from two
breaker CTs.
• One faceplate RJ45 port for testing and setting
• Clock synchronization via Pulse-Per-Second, IRIG-B and • The differential current is monitored continuously. If the dif-
SNTP ferential current exists for a long time, an alarm will be is-
sued to awake the operators.

• The connector type is optional, one is the plug in/out terminal


Features connector and the other is the screw terminal connector. The
unique plug in/out terminal connectors are used to connect
• The relay is designed based on NR’s well established and the rear panel to the terminal blocks on the rack or cabinet,
proven UAPC hardware platform with multi-processor archi- making on-site commissioning and replacement much easier
tecture. The multi CPU technology supports parallel operat- than using traditional screw terminals.
ing simultaneously.
• The relay is compatible with IEC 61850-8-1 MMS, GOOSE
• The two independent data acquisition paths can prevent any and IEC 61850-9-2 Sampling Value and provides the inde-
undesired trip caused by component failure. One works as a pendent interfaces for station bus and process bus respec-
fault detector and the other is designed for protection and its tively.
logic. Tripping outputs are supervised by the fault detector to
prevent a mal-operation.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC

Read more on the web


www.nrelect.com read more on www.nrelect.com 71
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class: IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32

Read more on the web


72 read more on www.nrelect.com www.nrelect.com
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 73
RCS-924
Stub Differential Relay

The RCS-924 relay provides current differential protection


with overcurrent elements for one-and-a-half breaker and
ring breaker applications. It integrates 3 or 4 CT inputs for
three-terminal or four-terminal system. It provides overcurrent
elements for energizing a faulty bus or energizing a faulty
line. It is fully compatible with IEC 61850 communication.

automatically become a 2-terminal or a 3-terminal differential


protection.

• The patented adaptive floating threshold method is adopted,


which is insensitive to system unbalance and disturbance.
The measuring element can get both high security and high
speed simultaneously.

Functions • Overcurrent protection is provided in the relay for energizing


a faulty bus or energizing a faulty line.
• 3-terminal or 4-terminal current differential protection. (87) • Innovative technology to prevent any undesired trip caused
• Two-level phase overcurrent protection. (50P/51P) by any component failure is adopted. The relay has two
• Overcurrent protection for energizing a faulty bus or a faulty independent data acquisition paths, one for a fault detector
line. (50E) and the other for protection and its logic. Tripping outputs are
supervised by the fault detector to prevent any mal-operation.
• CT failure detection logic.
• Tripping/Closing circuit supervision. • The connector type can be selected as plug in/out terminal
connector or crimp terminal connector. The unique plug in/
• Current drift auto adjustment.
out terminal connectors from the relay rear panel to the
• Self diagnostic test. terminal blocks on the rack or cabinet makes the on-site
• GPS clock synchronization. commissioning and replacement much easier than the
• Fault Recorder. traditional screw terminals when you do the commissioning.

• 64 tripping reports, 64 alarm reports and 64 binary input • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a


status change reports. measurement, calculation and logic discrimination could be
• High resolution oscillography of last 24 oscillograms. done within one sampling period. The event recording and
(Compatible with international COMTRADE format) protection logic calculation are completed simultaneously.

• Rear communication ports: Ethernet with IEC 61850 or 2 • The relay provides GPS clock synchronization, including
RS-485 with IEC 60870-5-103 protocol, 1 RS-485 with clock message, second pulse, minute pulse and IRIG-B
synchronization, 1 RS-232 or RS-485 with printer. synchronization.
• Front communication port: 1 RS-232 for testing and setting. • The format of event report is compatible with international
COMTRADE file.

• The relay is compatible with multiple protocols- IEC61850


Features and IEC 60870-5-103. It provides networking interface such
as RS485, RS232 and Ethernet port.

• Current differential protection for 3-terminal or 4-terminal


connections. When one of the terminals is open, the relay will

Read more on the web


74 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class; IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Read more on the web


www.nrelect.com read more on www.nrelect.com 75
Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV

76 read more on www.nrelect.com


Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

read more on www.nrelect.com 77


RCS-922
Stub Differential Relay

The RCS-922 relay is a current differential protection for


a stub between two breakers in one-and-a-half breaker
arrangements or ring breaker arrangements. The function
is activated when the line isolator is open. It can also be
applied as current differential protection for short lines. It
provides overcurrent elements for energizing a faulty bus or
energizing a faulty line. It is fully compatible with IEC 61850
communication.

Features
• The patented adaptive floating threshold method is adopted,
which is insensitive to system unbalance and disturbance.
The measuring element can get both high security and high
speed simultaneously.

• Overcurrent protection is provided in the relay for energizing


a faulty bus or energizing a faulty line.

• Innovative technology to prevent any undesired trip caused


by any component failure is adopted. The relay has two
independent data acquisition paths, one for a fault detector

Functions and the other for protection and its logic. Tripping outputs
are supervised by the fault detector to prevent any mal-
• Current differential protection. (87) operation.
• Two-stage overcurrent protection for energizing a bus or a • The connector type can be selected as plug in/out terminal
line (50E) connector or crimp terminal connector. The unique plug in/
• CT failure open detection logic. out terminal connectors from the relay rear panel to the ter-
minal blocks on the rack or cabinet makes the on-site com-
• Tripping circuit supervision.
missioning and replacement much easier than the traditional
• Current drift auto adjustment. screw terminals when you do the commissioning.
• Self diagnostic.
• On the premise of 24 samples per cycle, all data measure-
• Fault Recorder. ment, calculation and logic discrimination can be done within
• GPS clock synchronization. one sampling period. The event recording and protection
• 64 tripping reports, 64 alarm reports and 64 binary input sta- logic calculation are completed simultaneously.
tus change reports. • The relay provides GPS clock synchronization, including
• High resolution oscillography of last 24 oscillograms. (Com- message, second pulse, minute pulse and IRIG-B synchro-
patible with international COMTRADE format) nization.
• Rear communication ports: Ethernet with IEC 61850 or 2 • The format of event report is compatible with international
RS-485 with IEC 60870-5-103 protocol, 1 RS-485 with clock COMTRADE file.
synchronization, 1 RS-232 or RS-485 with printer.
• The relay is compatible with multiple protocols- IEC61850
• Front communication port: 1 RS-232 for testing and setting.
and IEC 60870-5-103. It provides networking interface such
as RS485, RS232 and Ethernet port.

Read more on the web


78 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class; IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Read more on the web


www.nrelect.com read more on www.nrelect.com 79
Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level
Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV

Read more on the web


80 read more on www.nrelect.com www.nrelect.com
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 81
RCS-925
Voltage Relay with DTT Supervision

The RCS-925 relay provides overvoltage and fault detector


protection for transmission lines. It can receive tripping
commands from the relay at the opposite end of line via
communication channel(direct transfer trip). Transfer trip
associates with local auxiliary criterion can improve the
security of protective device and not decrease the reliability
of protective device. Additionally, the RCS-925 can also
provide overvoltage protection and initiate transfer trip when
overvoltage element operates.

485 difference level and IRIG-B synchronization


• High-speed 64 Kbit/s PCM channel or 2048 Kbit/s dedicated
optical fiber channel for differential protection data
exchanging
• VT circuit failure detection logic

Communications
Functions
• 2 RS-485 communication rear ports conform to IEC 60870-5-
Protection and Control 103 protocol

• Overvoltage protection (59) • 1 RS-485 communication rear ports for clock synchronization

• Direct transfer trip (DTT) • 1 RS-232 or RS-485 (can be set by jumper) communication
• Overvoltage element with compensation rear ports for printer

• Undervoltage element with compensation • 1 RS-232 communication faceplate port for testing and
• DPFC overcurrent element setting

• Zero-sequence and negative sequence overcurrent element • 2 optional Ethernet ports, IEC 61850, or IEC 60870-5-103
over TCP/IP
• Undercurrent element
• Low power factor element
• Low active power element
Features
Monitoring and Metering • High compensation accuracy since the influence of distributed
capacitance on protective device is considered adequately
• Voltage and current drift auto regulation
in overvoltage with compensation and undervoltage with
• Self diagnostic compensation.
• Circuit breaker supervision
• The RCS-925 can provide completed local auxiliary criterion
• Event Recorder including 128 binary input change reports, which can reflect all fault types so as to improve the reliability
128 miscellaneous reports and of transfer trip.
• 128 self-supervision reports. • The self-adaptive floating threshold only reflects the deviation
• Disturbance recorder including 128 fault reports, and 24 of power frequency component and thus can defend system
oscillograms (The file format of disturbance recorder is unbalance and system disturbance.
compatible with international COMTRADE file.) • The connector type can be selected as plug in/out terminal
• GPS clock synchronization - second pulse, minute pulse, RS- connector or crimp terminal connector. The unique plug in/

Read more on the web


82 read more on www.nrelect.com www.nrelect.com
out terminal connectors from the relay rear panel to the m e s s a g e , s e c o n d p u l s e , m i n u t e p u l s e a n d IR I G - B
terminal blocks on the rack or cabinet makes the on-site synchronization.
commissioning and replacement much easier than the
• The relay is compatible with multiple protocols- IEC61850
traditional screw terminals when you do the commissioning.
and IEC 60870-5-103. It provides networking interface such
• The relay provides GPS clock synchronization, including as RS485, RS232 and Ethernet port.

Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms

Read more on the web


www.nrelect.com read more on www.nrelect.com 83
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class: IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level

Read more on the web


84 read more on www.nrelect.com www.nrelect.com
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 85
Busbar Protection
Busbar Protection Applications
How our products provide reliable, fast and accurate protection through our patented techniques are described in this section. Technical data of
different devices are provided in the each relaying description.

Function Index

RCS-915AB

RCS-915CD
RCS-915AS
PCS-915IC

PCS-915ID

RCS-915E

RCS-9628
Functional
Function
Code

Centralized busbar protection √ √ √ √ √


Distributed busbar protection √
Restraint current differential protection 87P √ √ √ √ √ √
DPFC current differential protection 87D √ √ √ √ √ √
Check zone and discrimination zone for bus selection √ √ √ √ √ √
Voltage control element √ √ √ √ √ √
Breaker failure protection for feeders 50BF √ √ √ √ √
Breaker failure protection for bus coupler and bus section 50BF √ √ √ √ √
Dead zone protection for feeders 50D √ √ √ √ √
Dead zone protection for bus coupler and bus section 50D √ √ √ √ √
Pole discrepancy protection for feeders 62PD √ √ √ √ √
Pole discrepancy protection for bus coupler and bus section 62PD √ √ √ √ √
Switch-onto-fault protection for bus coupler and bus section SOTF √ √ √ √ √
Phase and neutral overcurrent protection for feeders 50/51 √ √
Phase and neutral overcurrent protection for bus coupler and
50/51 √ √ √ √ √
bus section
Undervoltage protection 27 √
Overvoltage protection 59 √
Zero sequence overvoltage protection 59N √
Negative sequence overvoltage protection 47 √
Mechanical protection MR √
CT saturation detection logic √ √ √ √ √ √
Different CT ratio regulation √ √ √ √ √ √
CT failure detection supervision CTS √ √ √ √ √ √
VT failure detection supervision VTS √ √ √ √ √ √
GPS clock synchronization √ √ √ √ √ √ √
Fault Recorder FR √ √ √ √ √ √ √
IEC60870-5-103 √ √ √ √ √ √ √
IEC61850-8-1 MMS & GOOSE for station bus √ √ √ √ √ √
IEC61850-9-2 SV & GOOSE for process bus √ √
DNP3.0 LAN √ √
Application for single-busbar √ √ √ √
Application for double-busbar √ √ √ √
Application for double busbar with transfer bus √ √ √ √
Application for double busbar with bus section √ √ √ √
3/2 breaker and ring-breaker arrangements √ √ √ √
Configurable I/O and LED √ √
Programmable logic √ √

86 read more on www.nrelect.com


PCS-915IC
Centralized Busbar Protection

The PCS-915IC centralized busbar protection provides


comprehensive and scalable busbar and breaker failure
protection of single busbar with/without section, double
busbar with/without sections, double busbar with transfer
Functions bus, breaker-and-a-half arrangement and ring-breaker
arrangement. It provides fast and secure low impedance
Protection and Control busbar protection with sub-cycle tripping time. Check zone
and discrimination zone of differential protection are equipped
• Busbar current differential protection (87B)
in the relay to guarantee reliability. Advanced and patented
It composites phase current differential protection and DPFC
features are incorporated to improve sensitivity and security,
differential protection. Voltage control element and CT
such as innovative DPFC current differential protection and
saturation blocking element are available to supervise this
unique weighted CT saturation detection method. The relay
current differential protection.
adopts scalable and expandable architecture to protect up
- Percentage restraint phase current differential protection to 24 bays, including bus coupler/section. The integrated
Dual restraint coefficients are provided to enhance the sensitivity frequency-tracking algorithm is used to acquire accurate
of weak-sourced bus with opened bus coupler/section. current/voltage value. It provides the interfaces for station
- Percentage restraint DPFC differential protection bus and process bus respectively and supports IEC 61850-8-
DPFC differential protection is sensitive to high resistance fault 1 MMS, GOOSE, IEC 61850-9-2 Sampling Value.
and is immune to load current variation.
- Voltage control element
The voltage could be selected to use phase voltage, residual
voltage and/or negative sequence voltage. bus coupler/bus section tripping and bay breaker tripping are
executed sequentially.
- CT saturation inhibit
Two principles for CT saturation detection are provided: patented - Dead zone protection (50DZ)
adaptive weighted anti-saturation algorithm and harmonics. It It is provided to clear the dead zone fault between CT and
keeps the current differential protection stable to external fault breaker for all feeder bays.
and quickly clears internal fault and external-to-internal evolving - Pole disagreement protection (62PD)
fault during CT saturation. Pole discrepancy detection element is used to protect pole
- Check zone and discrimination zone position disagreement
Check zone differential element and discrimination zone - Overcurrent protection (50/51)
differential element are both provided to enhance the reliability. Overcurrent protection consists of phase overcurrent element
• Bus coupler/section protection and neutral overcurrent element, each can be set as inverse-
- Breaker failure protection (50BF) time or definite-time.
It can be supervised by voltage control element. Re-tripping, bus • Voltage and current drift auto adjustment.
coupler/bus section tripping and bay breaker tripping are issued The relay automatically traces the drift and adjusts zero point
sequentially. to normal value for voltage and current.
- Dead zone protection (50DZ)
It is provided to clear the dead zone fault between CT and • Frequency tracking.
breaker for bus coupler/section bays. Frequency tracking is provided to accommodate the
- Pole disagreement protection (62PD) frequency shift in power system.
Pole discrepancy detection element is used to protect pole
position disagreement Monitoring and Metering
- Switch-onto-fault protection (50SOTF)
• CT failure supervision
Switch-onto-fault logic of bus coupler/section is used for bus
energizing.
• VT failure supervision

- Overcurrent protection (50/51)


• Dynamic busbar replica
Phase and neutral overcurrent protection with time delay are • Isolator contact discrepancy alarm
both provided. • Self diagnostic test
• Feeder protection • Event recorder including 1024 disturbance records, 1024
- Breaker failure protection (50BF) binary events, 1024 supervision events and 1024 operating
It can be supervised by voltage control element. Re-tripping, logs.

read more on www.nrelect.com 87


• Disturbance recorder including 64 disturbance records • The ratio of CT on each bay could be differential and could
with waveforms (The file format of disturbance recorder is be regulated by configurable coefficients in software.
compatible with international COMTRADE file.)
• The relay detects dynamic connection status of each bay
• Fault Recorder in order to dynamically introduce the current input into the
differential calculations or not.
Communications
• The relay provides isolator monitoring function responding to
• Two 10Base-T/100Base-TX (RJ45) ports and two optional both normally open and normally closed auxiliary contacts.
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
• Traditional harmonics and patented adaptive weighted anti-
non-time-critical message, IEC 60870-5-103 over TCP/IP or
saturation algorithm are provided for CT saturation detection.
DNP 3.0
• Two RS-485 rear ports with IEC 60870-5-103 • DPFC differential protection is integrated to coordinate with
percentage restraint phase current differential protection and
• Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling
improve the sensitivity and tripping speed.
Value and GOOSE for time-critical message
• One RS-485 rear port for clock synchronization • Innovative technology to prevent any undesired trip caused
by any component failure is adopted. The relay has two
• One RS-232 rear port for printer
independent data acquisition paths, one for fault detector
• One faceplate RJ45 port for testing and setting and the other for protection and its logic. Tripping outputs
• Clock synchronization via Pulse-Per-Second, IRIG-B and are supervised by the fault detector to prevent any mal-
SNTP operation.

• The connector type can be selected as plug in/out terminal


connector or screw terminal connector. The unique plug
Features in/out terminal makes the on-site commissioning and
replacement much easier than the traditional screw terminals
• The typical pickup time of current differential protection is when you do the commissioning.
less than 15 ms.
• The relay is compatible with IEC 61850-8-1 MMS, GOOSE
• The relay is based on NR’s well established and proven and IEC 61850-9-2 Sampling Value and provides the
UAPC hardware platform of multi-processor. independent interfaces for station bus and process bus
respectively.
• The relay can select the faulty bus and make a selective
trip correctly via check zone and discrimination zone of
differential protection.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<25W (4U)
Quiescent condition
<45W (8U)
Burden
<35W (4U)
Operating condition
<60W (8U)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 100In
for half a cycle 250In
Burden <0.15VA/phase < 0.25VA/phase

Read more on the web


88 read more on www.nrelect.com www.nrelect.com
Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V
linear to 1~170V
continuously 200V
Thermal withstand capability 10s 260V
1s 300V
Burden < 0.20VA/phase @Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 48V 110V 125V 220V 250V
Rated current 1.2mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 55%~70% of rated voltage
Dropout voltage <55% of rated voltage
Maximum permissive voltage 120% of rated voltage
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
482.6mm×177mm×291mm(4U),
Enclosure dimensions (W×H×D)
482.6mm×354.8mm×285mm (8U)
Mounting Flush mounted
450mm×179mm(4U), M6 screw
Trepanning dimensions (W×H)
450mm×356.8mm(8U), M6 screw
Housing color Silver grey
Protection class: IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

Read more on the web


www.nrelect.com read more on www.nrelect.com 89
- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Optical fiber port For Station Level For Process Level For Synchronization Port
Characteristic Glass optical fiber Glass optical fiber Glass optical fiber
Terminal ST, SC LC ST
Fibre size Multi mode Multi mode Multi mode
Transmission distance <2km <2km <2km
Wave length 1310nm 1310nm 820nm
Transmission power Min. -20.0dBm Min. -20.0dBm
Minimum receiving power Min. -30.0dBm Min. -30.0dBm Min. -25.0dBm
System reserve Min +3dB Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns

Read more on the web


90 read more on www.nrelect.com www.nrelect.com
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 91
PCS-915ID
Distributed Busbar Protection

The PCS-915ID distributed busbar protection is used for


protecting and monitoring various busbar arrangement
with all voltage levels, including single busbar with/without
section, double busbar with/without sections, double busbar
with transfer bus, breaker-and-a-half arrangement and
ring-breaker arrangement. It adopts distributed structure,
consisting of one Central Unit (CU) and a number of Bay
Units (BU). The central unit is linked to bay units via optical
fibers in point-to-point communication mode. The central
unit is responsible for the protection calculation and relay
management, the bay unit acquires and transmits the analog
and binary data and executes the trip/close command issued
from Central Unit.

The device provides fast and secure low impedance busbar


protection with sub-cycle tripping time. It integrates advanced
and patented features to improve its sensitivity and security,
such as innovative DPFC current differential protection and
Functions unique weighted CT saturation detection method. It also
provides breaker failure protection for all bays. The integrated
Protection and Control frequency-tracking algorithm is used to acquire accurate
current/voltage value. It provides the interfaces for station
• Busbar current differential protection (87B)
bus and process bus respectively and supports IEC 61850-
It composites phase current differential protection and DPFC
8-1 MMS, GOOSE, IEC 61850-9-2 Sampling Value.
differential protection. Voltage control element and CT
saturation blocking element are available to supervise this
current differential protection.
- Percentage restraint phase current differential protection
Dual restraint coefficients are provided to enhance the sensitivity - Dead zone protection (50DZ)
It is provided to clear the dead zone fault between CT and
of weak-sourced bus with opened bus coupler/section.
breaker for bus coupler/section bays.
- Percentage restraint DPFC differential protection
DPFC differential protection is sensitive to high resistance fault - Pole disagreement protection (62PD)

and is immune to load current variation. Pole discrepancy detection element is used to protect pole
position disagreement
- Voltage control element
The voltage could be selected to use phase voltage, residual - Switch-onto-fault protection (50SOTF)

voltage and/or negative sequence voltage. Switch-onto-fault logic of bus coupler/section is used for bus
energizing.
- CT saturation inhibit
Two principles for CT saturation detection are provided: patented - Overcurrent protection (50/51)

adaptive weighted anti-saturation algorithm and harmonics. It Phase and neutral overcurrent protection with time delay are

keeps the current differential protection stable to external fault both provided.

and quickly clears internal fault and external-to-internal evolving • Feeder protection
fault during CT saturation. - Breaker failure protection (50BF)

- Check zone and discrimination zone It can be supervised by voltage control element. Re-tripping,

Check zone differential element and discrimination zone bus coupler/bus section tripping and bay breaker tripping are

differential element are both provided to enhance the reliability. executed sequentially.
- Dead zone protection (50DZ)
• Bus coupler/section protection It is provided to clear the dead zone fault between CT and
- Breaker failure protection (50BF) breaker for all feeder bays.
It can be supervised by voltage control element. Re-tripping, bus - Pole disagreement protection (62PD)
coupler/bus section tripping and bay breaker tripping are issued Pole discrepancy detection element is used to protect pole
sequentially. position disagreement

92 read more on www.nrelect.com


- Overcurrent protection (50/51)
Overcurrent protection consists of phase overcurrent element
Features
and neutral overcurrent element, each can be set as inverse- • The typical pickup time of current differential protection is
time or definite-time. less than 15 ms.
• Voltage and current drift auto adjustment.
• The relay adopts the distributed structure based on multi-
The relay automatically traces the drift and adjusts zero
processor platform. The optical fiber communication between
point to normal value for voltage and current.
Central Unit and Bay Units are continuously monitored. If a
failure occurred in the communication of Central Unit to any
• Frequency tracking.
Bay Unit, the current differential protection will be blocked to
Frequency tracking is provided to accommodate the
prevent mal-operation.
frequency shift in power system.
• The relay can select the faulty bus and make a selective
trip correctly via check zone and discrimination zone of
Monitoring and Metering differential protection.
• CT failure supervision • The ratio of CT on each bay could be differential and could
• VT failure supervision be regulated by configurable coefficients in software.
• Dynamic busbar replica • The relay detects dynamic connection status of each bay
• Isolator contact discrepancy alarm in order to dynamically introduce the current input into the
• Self diagnostic differential calculations or not.

• Event recorder including 1024 disturbance records, 1024 • The relay provides isolator monitoring function responding to
binary events, 1024 supervision events and 1024 operating both normally open and normally closed auxiliary contacts.
logs
• Traditional harmonics and patented adaptive weighted anti-
• Disturbance recorder including 64 disturbance records saturation algorithm are provided for CT saturation detection.
with waveforms (The file format of disturbance recorder is
compatible with international COMTRADE file.) • DPFC differential protection is integrated to coordinate with
percentage restraint phase current differential protection and
• Fault Recorder
improve the sensitivity and tripping speed.

• Innovative technology to prevent any undesired trip caused


Communications
by any component failure is adopted. The relay has two
• Point-to-point optical fiber communication between Central independent data acquisition paths, one for fault detector
Unit and Bay Unit and the other for protection and its logic. Tripping outputs
• Two 10Base-T/100Base-TX (RJ45) ports and two optional are supervised by the fault detector to prevent any mal-
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for operation.
non-time-critical message, IEC 60870-5-103 over TCP/IP or • The connector type can be selected as plug in/out terminal
DNP 3.0 connector or screw terminal connector. The unique plug
• Two RS-485 rear ports with IEC 60870-5-103 in/out terminal makes the on-site commissioning and
• Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling replacement much easier than the traditional screw terminals
Value and GOOSE for time-critical message when you do the commissioning.

• One RS-485 rear port for clock synchronization • The relay is compatible with IEC 61850-8-1 MMS, GOOSE
• One RS-232 rear port for printer and IEC 61850-9-2 Sampling Value and provides the
independent interfaces for station bus and process bus
• One faceplate RJ45 port for testing and setting
respectively.
• Clock synchronization via Pulse-Per-Second, IRIG-B and
SNTP

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
Quiescent condition <25W (4U)
Burden
Operating condition <35W (4U)

read more on www.nrelect.com 93


Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 100In
for half a cycle 250In
Burden <0.15VA/phase < 0.25VA/phase

Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V
linear to 1~170V
continuously 200V
Thermal withstand capability 10s 260V
1s 300V
Burden < 0.20VA/phase @Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 48V 110V 125V 220V 250V
Rated current 1.2mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 55%~70% of rated voltage
Dropout voltage <55% of rated voltage
Maximum permissive voltage 120% of rated voltage
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
Burden 300mW 240mW
Making capacity 2000VA 3040VA
6A@3s 10A@3s
Short duration current
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177mm×291mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450mm×179mm(4U), M6 screw
Housing color Silver grey
Protection class: IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Read more on the web


94 read more on www.nrelect.com www.nrelect.com
Ambient Temperature and Humidity Range
Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Optical fiber port For Station Level For Process Level For Synchronization Port
Characteristic Glass optical fiber Glass optical fiber Glass optical fiber
Terminal ST, SC LC ST
Fibre size Multi mode Multi mode Multi mode
Transmission distance <2km <2km <2km
Wave length 1310nm 1310nm 820nm
Transmission power Min. -20.0dBm Min. -20.0dBm
Minimum receiving power Min. -30.0dBm Min. -30.0dBm Min. -25.0dBm
System reserve Min +3dB Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC
- Electromagnetic Compatibility

Read more on the web


www.nrelect.com read more on www.nrelect.com 95
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


96 read more on www.nrelect.com www.nrelect.com
RCS-915
Centralized Busbar Protection

The RCS-915 series busbar protection devices provide main


and back-up protection of busbars for all kinds of busbar
wiring configurations, such as single busbar, double busbar,
double busbar with transfer bus, double busbar with section,
one-and-a-half breaker, etc. It is fully compatible with IEC
61850 communication with an additional communication unit.

• 32 latest fault reports, 32 latest self-supervision reports and


32 latest status change of binary input reports
• 8 latest fault waveforms (The file format of disturbance
recorder is compatible with international COMTRADE file)
• 2 RS-485 communication rear ports (option optical fibre
interface)
• 1 RS-485 communication rear ports for time synchronization
• 1 RS-232 communication rear ports for printer
• 1 RS-232 communication front port for debugging
• Support IEC60870-5-103 protocol
• Support ModBus protocol
• Support IEC61850 protocol (through external auxiliary
device) and IEC 60870-5-103 communication protocol

Functions
Features
• Busbar differential protection. (87B)
- Steady-state percentage differential protection • The RCS-915 provides less than 20ms typical trip time for
- DPFC percentage differential protection busbar differential protection.
• Bus coupler/section protection.
• The CPU system adopts parallel calculation.
- SOTF protection (50)
- Dead zone protection (51/62EF) • Independent fault detector element is equipped.
- Breaker failure protection (50BF)
- Overcurrent protection (51P/51N)
• The device integrates high sensitive percentage differential
- Pole discrepancy protection (51/62PD)
protection.
• Feeder protection. • It is matching to different CT ratios and settable CT
- Breaker failure protection (50BF) adjustment coefficient.
- End fault protection (51/62EF)
- Pole discrepancy protection (51/62PD) • Busbar differential element can be supervised by voltage
- Transfer trip (TT)
elements.

• CT circuit failure supervision. • The sensitive and high-speed DFPC current differential
element is integrated in the relay.
• VT circuit failure supervisionCT failure detection logic.
• Disconnected position alarm. • A fully-fledged adaptive weighted anti-saturation algorithm.
• Busbar voltage switching. • The breaker failure protection of all feeders, bus coupler and
• Receiving PPS (pulse per second) and PPM (pulse per bus section is integrated in the RCS-915 relay.
minute) via external contact
• Various GPS clock synchronizations are provided: second/
• Receiving PPS, PPM and IRIG-B signal via RS-485 minute pulse via binary input or RS-485, message via
• Receiving time synchronization message from substation communication ports and IRIG-B synchronization.
automation system

Read more on the web


www.nrelect.com read more on www.nrelect.com 97
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
< 40 W (RCS-915AB, RCS-915E, RCS-915AS)
Quiescent condition
< 45 W (RCS-915CD)
Burden
< 70 W (RCS-915AB, RCS-915E, RCS-915AS)
Operating condition
< 60 W (RCS-915CD)
Backup battery type 1/2AA, 3.6V, 60mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 5A 8A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 4ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×353.6×285 (unit: mm)
Trepanning dimensions (W×H) 450×355 (unit: mm) M6 screw
Mounting Flush mounted

Read more on the web


98 read more on www.nrelect.com www.nrelect.com
Housing material Aluminum
Housing color Silver grey
Protection class: IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
RS-485 (EIA) Connector type ST
Baud rate 4800 ~ 38400bps
Transmission standard 100Base-FX,
Optical Transmission distance <1500m
(Optional) Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local human-machine communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800 ~ 9600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 99
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


100 read more on www.nrelect.com www.nrelect.com
RCS-9628
Busbar Voltage Relay

The RCS-9628 busbar voltage relay is designed for the


voltage protection, control and monitoring of busbar
in impedance grounded, Peterson coil grounded and
ungrounded system. The relay is suitable to be flush mounted
into a control panel.

check alarm elements, protection elements and binary input


elements.
• Circuit breaker operating counter

Auxiliary Testing
• Virtual SOE records generation
• Virtual measurement values generation
• Virtual tripping reports generation
• Virtual fault wave records generation

Features
• On the premise of 24 samples per cycle, all data
measurement, calculation and logic discrimination can be
Functions finished within one sampling period. The event recording and
protection logic calculation can be finished simultaneously.
Protection and control • Definite time overvoltage protection and residual overvoltage
• Undervoltage protection. (27) protection are both provided.
• Overvoltage protection. (59)
• Negative sequence overvoltage element is provided in this
• Residual overvoltage protection (59N) relay.
• Negative sequence overvoltage element (47)
• The relay constantly measures and calculates a large
• Mechanical protection (MR) amount of analog quantities, such as phase-to-phase
• Voltage drift automatic adjustment voltage, phase voltage, neutral voltage and system
frequency.
• Self supervision
• Voltage transformer supervision (VTS) • Multiple GPS clock synchronization, including message,
pulse per second, and IRIG-B synchronization.

Management and Mertering • The relay is equipped with two EIA RS-485 standardized
• Tripping circuit supervision interfaces and two Ethernet interfaces. Two optional Ethernet
interfaces are provided: electrical or optical.
• Remote control and measurements.
• 64 Trip records • The relay can communicate with SAS or RTU using
IEC60870-5-103 or modbus.
• 64 Operating alarm records
• 64 Self-check alarm records • Perfect fault and disturbance record function: 64 latest fault
reports, 8 latest fault waves(up to 15s), 64 user operating
• 64 User operating records
records, and 256 records of time tagged sequence of event
• 8 Disturbance records can be recorded.
• 256 SOE records, latest records of following elements
state changing: operating abnormality alarm elements, self-

Read more on the web


www.nrelect.com read more on www.nrelect.com 101
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6, 1988
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs:
Rated Voltage 110VDC 220VDC 125VDC 250VDC
Pickup voltage 77VDC 154VDC 87.5VDC 175VDC
Dropout voltage 60.5VDC 121VDC 68.8VDC 137.5VDC
Maximum permitted voltage 150V 300V 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000Vac rms for 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

DC Output
Output range 4 ~ 20mA
Max load resistance 500ohm
Max output voltage 10V

Atmospheric Environment
Standard IEC60255-6:1988
Operating temperature range -25 °C ~ +55 °C
Transport and storage temperature range -40 °C ~ +70 °C
Permissible humidity 5% ~ 95%, condensation not permissible

Mechanical Specifications
Enclosure dimensions (W×H×D) 142.4×266.0×203.0 (unit: mm)
Trepanning dimensions (W×H) 154×268.0 (unit: mm), M5 screw
Mounting Way Flush mounted

Read more on the web


102 read more on www.nrelect.com www.nrelect.com
Local control panel Small control module: 3 LED indicators, a 9-key keypad and a 160×80-dot LCD
Housing material Aluminum
Housing color Silver grey
Protection class: IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Communication Interfaces:
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Ethernet
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Optical Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Fiber Type Multi-mode
Wavelength 1300nm
Ethernet Optical
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2007 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz /450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2008 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns

Read more on the web


www.nrelect.com read more on www.nrelect.com 103
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m for 1 minute
1000A/m for 3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:1974, 16 hours at +55°C
Dry cold test IEC60068-2-1:1990, 16 hours at -25°C
IEC60068-2-30:1980, two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

104 read more on www.nrelect.com


Transformer Protection
Transformer Protection Applications
How our products provide reliable, fast and accurate protection through our patented techniques are described in this section. Technical data of
different devices are provided in each relaying description.

Function Index

RCS-9621

RCS-9661

RCS-9671

RCS-9679

RCS-9681

RCS-9622

RCS-9624
PCS-9671
RCS-978

RCS-974
PCS-978

PCS-974
Functional
Function
Code

Unrestraint current differential protection for transformer 87UT √ √ √ √ √ √


Restraint current differential protection for transformer 87PT √ √ √ √ √ √
DPFC differential protection for transformer 87DT √ √
Unrestraint current differential protection for reactor 87UR √
Restraint current differential protection for reactor 87PR √
DPFC differential protection for reactor 87DR √
Winding differential protection for transformer 87W √ √
Restricted earth fault protection REF √ √ √ √ √ √ √
Inter-turn fault protection 32G/21G √
Overexcitation protection 24 √ √ √
Mechanical protection MR √ √ √ √ √ √ √ √ √
Directional phase overcurrent protection 67P √ √ √
Non-directional phase overcurrent protection 50/51P √ √ √ √ √ √ √ √ √
Directional zero-sequence overcurrent protection 67N √ √ √
Non-directional zero-sequence overcurrent protection 50/51N √ √ √ √ √ √ √ √
Negative-sequence overcurrent protection 50/51Q √ √ √
Phase overvoltage protection 59P √
Ground overvoltage protection 59G √ √ √ √ √
Undervoltage protection 27P √ √
Voltage rate-of-change blocking element √
Thermal overload protection 49 √ √ √ √ √ √ √
Breaker failure protection 50BF √ √ √
Pole disagreement protection 62PD √ √
Phase overcurrent alarm element √
Phase-to-phase impedance protection 21P √ √
Phase-to-ground impedance protection 21G √ √
Power swing blocking element PSB √ √
CT ratio compensation √ √ √ √ √ √
Vector group compensation √ √ √ √ √ √
CT failure supervision CTS √ √ √ √ √ √ √ √ √ √
VT failure supervision VTS √ √ √ √ √ √ √
On-load-tap-change(OLTC) blocking element √ √ √ √
Configurable I/O and LED √ √ √
Programmable logic √ √ √
GPS clock synchronization √ √ √ √ √ √ √ √ √ √ √
Remote/local control √ √ √ √ √ √ √ √
IEC 61850-8-1 MMS & GOOSE for station bus √ √ √ √ √ √ √ √ √ √ √
IEC 61850-9-2 SV & IEC 61850-8-1 GOOSE for
√ √ √
process bus
IEC 60870-5-103 √ √ √ √ √ √ √ √ √ √ √ √
DNP 3.0 LAN √ √ √

read more on www.nrelect.com 105


PCS-978
Transformer Protection

The PCS-978 numerical protection system can provide


full-scheme protection and control in one rack for various
transformer applications, including two-winding transformers,
three-winding transformers and auto-transformers. It also
can be used to protect shunt reactors. Up to 36 analog input
channels including current and voltage inputs are provided.
The extensive functional library, programmable logic and
configurable I/O are integrated to meet flexible applications.
Functions The unique current differential protection includes the
unrestraint current differential element, percentage restraint
Protection and Control current differential element and DPFC differential element.
• Transformer restrained current differential protection. (87PT)
Three slopes are provided for the restraint characteristic of The PCS-978 reserves two sets of CT input for dual-breaker
percentage current differential protection. It also integrates protection in one-and-a-half breaker and ring breaker
the inrush current blocking, CT saturation discrimination, arrangements. To enhance the accuracy of data sampling,
over excitation blocking, CT ratio compensation and unique the frequency-tracking function is used to trace the real-time
vector group compensations. current/voltage value.

• Unrestrained current differential protection. (87UT)


The unrestraint current differential protection instantaneously
Biased current differential protection consists of CT
responds and clears a serious fault immediately.
saturation and harmonic blocking elements
• DPFC baised current differential protection. (87DT)
• Reactor DPFC biased current differenital protection.
Deviation of Power Frequency Component (DPFC)
(7/87DR)
differential current protection is sensitive to turn-to-turn fault
DPFC biased current differential protection is regardless of
and high resistance fault and is immune to load current.
the load current and is sensitive to small internal fault current
within the reactor.
• Reactor restraint current differential protection. (87R)
Inrush current can be distinguished to avoid maloperation of
• Restricted Earth Fault Protection. (REF)
current differential protection by detecting harmonic
Zero sequence differential protection is used as REF for
each Wye-connection winding to detect sensitive ground
• Reactor unrestrained current differential protection.
fault. Up to 3 REF protections are provided.
(50/87UR)

Read more on the web


106 read more on www.nrelect.com www.nrelect.com
• Winding differential protection. (87W/87N) • Phase overcurrent alarm element. (50PAlm)
Winding differential protection has high sensitivity to internal The output could be used for the initiation of cooling system
earth faults. Up to 3 winding differential protections are and this element is not supervised by General Fault Detector
provided. element.

• Inter-turn fault protection. (32G/21G) • Phase-to-phase impedance protection for HV and MV side.
Inter-turn protection consists of zero-sequence power (21P)
directional element and zero-sequence impedance element. Users have options to select the forward direction or
backward direction by logic setting, and power swing
• Overexciation protection. (24) blocking logic is integrated to improve the safe operation.
Overexcitation protection based on the ratio of voltage and
frequency is provided. • Phase-to-ground impedance protection for HV and MV side.
(21G)
Users have options to select the forward direction or
• Underfrequency and overfrequency protection. (81U/81O)
backward direction by logic setting, and power swing
Under frequency protection with df/dt blocking and over
blocking logic is integrated to improve safe operation.
frequency protection are both provided. The frequency is
derived from positive-sequence voltage.
• Power swing blocking. (68)
The unique power swing blocking logic is integrated to
• Mechanical protection. (MR)
improve the safe operation of impedance protection.
Under frequency protection with df/dt blocking and over
frequency protection are both provided. The frequency
• Voltage and current drift auto adjustment.
is derived from positive-sequence voltage. Up to eight
The relay continually and automatically traces the voltage
channels of mechanical protection are provided for tank.
and current drifts and adjusts the zero point to the normal
value.
• Four stage phase overcurrent protection (50P/51P/67P)
Overcurrent protection can be supervised by voltage
• Frequency tracking.
element, harmonic element and directional element. IDMT
Frequency tracking is provided to accommodate the
curves complied with IEC and ANSI are provided for
frequency shift in power system.
selection. Up to four overcurrent protections are provided.

• Four stage zero sequence overcurrent protection for each Monitoring and Metering
side. (50N/51N/67N) • CT saturation detection.
Overcurrent protection can be supervised by voltage
• Inrush current detection.
element, harmonic element and directional element. IDMT
curves complied with IEC and ANSI are provided for • Overexcitation detection.
selection. Up to four zero-sequence overcurrent protections • Harmonic blocking function.
are provided. • CT failure detection supervision.
• VT failure detection supervision.
• Two-stage residual overvoltage protection. (59G)
IDMT curves complied with IEC and ANSI are provided for • Tripping circuit supervision.
selection. • Self diagnostic.
• Fault Recorder.
• Two-stage definite-time and inverse-time phase overvoltage
protection. (59P)
IDMT curves complied with IEC and ANSI are provided for Communications
selection. • Two 10Base-T/100Base-TX (RJ45) ports and two optional
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
• Four-stage undervoltage protection. (27) non-time-critical message, IEC 60870-5-103 over TCP/IP or
Rate-of-change of voltage is provided for the blocking. DNP 3.0
• Two RS-485 rear ports with IEC 60870-5-103
• Thermal overload protection. (49)
Thermal overload protection based on fundamental current • Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling
or harmonic current is provided for tripping and alarm. Value and GOOSE for time-critical message
• One RS-485 rear port for clock synchronization
• Breaker failure protection. (50BF) • One RS-232 rear port for printer
Breaker failure protection for each breaker is supplied to
• One faceplate RJ45 port for testing and setting
initiate re-tripping and adjacent breaker tripping.
• Clock synchronization via Pulse-Per-Second, IRIG-B and
• Pole disagreement protection. (62PD) SNTP
External binary input and zero-sequence/negative-sequence
current are used to detect the pole disagreement state of the
circuit breaker.

Read more on the web


www.nrelect.com read more on www.nrelect.com 107
Features
• CT transient detection element based on the ratio of • The restraint current differential protection with initial restraint
zero-sequence current to positive-sequence current is slope consists of sensitive and conventional differential
provided for REF to eliminate the influence of CT transient elements as well as independent CT saturation criterion.
characteristic difference.
• Maximum 4 group CT and 1 neutral CT inputs for REF
• The PCS-978 provides RTD input module and DC mA input protection are provided.
module to detect the oil-temperature.
• The CT saturation detection function based on 2nd and 3rd
• Maximum six groups of CT inputs for differential protection harmonics is adopted to avoid maloperation.
are provided.
• The amplitude of residual voltage is compensated to ensure
• 24 vector groups are available for the application to two- that the zero-sequence power directional element can
winding transformer. distinguish the direction correctly when system impedance is
too small.
• 288 vector groups are available for the application to
3-winding transformer. • Voltage for overexcitation protection calculation is the RMS
value of three phase voltages which is not affected by
• Optional inrush current distinguished principle is provided:
frequency fluctuation.
harmonic criterion (second harmonic and third harmonic) or
waveform distortion. • Directional element can be selected to control each stage
phase overcurrent protection with three options: none
• There are two optional modes for harmonic criterion:
direction, forward direction and reverse direction.
self-adaptive blocking mode and phase-to-phase cross
blocking mode. Self-adaptive blocking mode can prevent • Disturbance records are composed of 64 fault reports and
maloperation during transformer energization effectively and 64 disturbance waveforms. The file format of waveform
ensure high speed for internal faults under normal operation. is compatible with international COMTRADE91 and
COMTRADE99 file. Up to 80 analog inputs and 200 binary
• Fifth harmonic or third harmonic criterion applied to detect
inputs can be recorded, and three oscillograph triggering
overexciation condition.
mode are supported.
• The Δ→Y vector group compensation is used to adjust
• The relay is compatible with IEC 61850-8-1 MMS, GOOSE
the phase angle of secondary current and the inrush
and IEC 61850-9-2 Sampling Value and provides the
current feature is reserved in each phase to realize phase-
independent interfaces for station bus and process bus
segregated inrush current restraint for percentage differential
respectively.
protection.

• The DPFC restraint current differential protection is immune


to load current but sensitive to small internal fault current
within the transformer.

Technical data

Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Read more on the web


108 read more on www.nrelect.com www.nrelect.com
Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Transducer Input
Standard IEC 60255-1:2009
Input range 0-20mA 0-10V 0-250V
Input resistance 235Ω 8.8kΩ 248kΩ
Accuracy 0.5 class 0.5 class 0.5 class

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class: IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Read more on the web


www.nrelect.com read more on www.nrelect.com 109
Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Temperature range -5°C ~+55°C -5°C ~+55°C
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV

Read more on the web


110 read more on www.nrelect.com www.nrelect.com
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 111
RCS-978
Transformer Protection

The RCS-978 relay is a full scheme protection used for


the main and backup protection for various transformer
applications, including two-winding transformers, three-
winding transformers, and auto-transformers. Up to 6 CT
inputs can be integrated in the current differential protection.
The RCS-978 is recommended to be applied to transformers
of high voltage level. The device is fully compatible with IEC
61850 communication with an additional communication unit.
Functions
• Percentage restraint differential protection. (87T)
• Unrestrained instantaneous differential protection. (50/87UT)
• DPFC current differential protection. (7/87DT)
• Common-and-serial-windings differential protection only for
• Voltage controlled directional overcurrent protection of MV
autotransformer (87ST)
side. (50P/51P/67P)
• Restricted Earth Fault Protection. (REF)
• Inverse-time overcurrent protection of MV side. (51P)
• Definite-time and inverse-time overexciation protection. (24)
• Zero sequence overcurrent protection for MVside.
• Voltage controlled directional overcurrent protection of HV (50N/51N/67N)
side. (50P/51P/67P)
• Ground overcurrent protection for MV. (50G/51G/67G)
• Inverse-time overcurrent protection of HV side. (51P)
• Voltage controlled directional overcurrent protection of LV
• Zero sequence overcurrent protection for HVside. side 1. (50P/51P/67P)
(50N/51N/67N)
• Inverse-time overcurrent protection of LV side 1. (51P)
• Ground overcurrent protection for HV. (50G/51G/67G)
• Voltage controlled directional overcurrent protection of LV
• Zero-sequence overvoltage protection of HV side. (59N) side 2. (50P/51P/67P)
• Inverse-time overcurrent protection of LV side 2. (51P)
• Z e r o s e q u e n c e o v e r c u r r e n t p r o t e c t i o n f o r LV s i d e .
(50N/51N/67N)
• Thermal overload protection. (49)
• Overload alarm functions of each side. (49)
• Overload initiating cooling function of HV side. (49)
• Block on-load tap changing during overload of HV side. (49)
• Definite-time and inverse-time overexciation alarm function.
(24)
• Zero-sequence overvoltage alarm functions of two branches
of LV side. (59N)
• Breaker failure initiation for HV side and MV side. (50BF)
• VT circuit failure supervision VTS
• CT circuit failure supervision CTS
• CT saturation detection
• Inrush current detection
• Overexcitation detection
• Voltage and current drift auto adjustment.
• 64 latest fault reports, 8 latest fault waveforms, 256 latest
abnormality reports and 1024 latest binary status input
change reports.
• GPS clock synchronization.

Read more on the web


112 read more on www.nrelect.com www.nrelect.com
Features more reliable due to the combination of voltage and current
value method.
• Main and backup protections are integrated in one set • The maximum requirements of backup protection of all sides
of protection equipment. Protection information such as of transformer are provided. The tripping output circuit can
sampled data and binary inputs is shared by all elements. be configured by tripping matrix and suitable to any mode of
tripping.
• Δ→Y transfer method is used to adjust phase angle
of secondary current on each side of the transformer. • The built-in reliable power swing blocking logic can properly
Therefore, the restraint current and differential current supervise the impedance protection during a power swing.
can be phase-segregated to distinguish the faulty phase The power swing blocking logic can make the relay stand
only with inrush current characteristic when transformer is aside for an external fault during a power swing and pickup
energized. for an internal fault.
• Two discrimination principles for inrush current are provided: • The RCS-978 relay is designed based on NR’s well
harmonics restraint and waveform distortion restraint. established and proven hardware platform of multi-
processor. Two CPU modules are adopted in the relay. Each
• The DPFC percentage differential protection is immune to
CPU module has one microprocessor and two digital signal
load current and is sensitive to small internal fault current in
processors (DSP). All CPUs can operate in parallel.
the transformer.
• The connector type can be selected as plug in/out terminal
• The calculated zero sequence current is used in zero
connector or screw terminal connector. The unique plug
sequence differential protection (or called restricted earth
in/out terminal connectors from the relay rear panel to
fault protection) and common-and-serial-windings differential
the terminal blocks on the rack or cabinet makes the on-
protection to avoid mal-operation resulting from mistaken
site commissioning and replacement much easier than the
polarity of zero sequence CT of each side of transformer.
traditional screw terminals when you do the commissioning.
Moreover CT ratio compensation of secondary zero
sequence current is realized by software. • Various GPS clock synchronizations are provided: second/
minute pulse via binary input or RS-485, message via
• The positive sequence current restraint element is
communication ports and IRIG-B synchronization.
adopted to eliminate the influence of difference of transient
characteristic and saturation of various CT on zero sequence • The relay is equipped with Ethernet ports with IEC 61850
percentage differential protection. (one additional communication unit is required) and RS-485
ports with IEC 60870-5-103.
• Distinguishing open and short circuit of CT against fault is

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 35 W
Burden
Operating condition < 45 W
Backup battery type 1/2AA, 3.6V, 60mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

Read more on the web


www.nrelect.com read more on www.nrelect.com 113
AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×353.6×285 (unit: mm)
Trepanning dimensions (W×H) 450×355 (unit: mm) M6 screw
Mounting Flush mounted
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level

Read more on the web


114 read more on www.nrelect.com www.nrelect.com
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local human-machine communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800 ~ 9600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 115
PCS-974
Transformer Auxiliary Relay

The PCS-974 relay provides mechanical protection for


transformer tanks. The source of mechanical protection can
be designed from non-electrical quantities, such as gas, oil
temperature, winding temperature, pressure and oil level. It
receives the mechanical inputs from transformer tank and
issues the tripping or alarm command with or without time
delay. The mechanical inputs employ the inputs with large
pickup power instead of common binary inputs.

• Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling


Value and GOOSE for time-critical message
• One RS-485 rear port for clock synchronization
• One RS-232 rear port for printer
• 1 faceplate RJ45 port for testing and setting
• Clock synchronization via Pulse-Per-Second, IRIG-B and
SNTP

Functions Features
Protection and Monitoring • The relay is designed based on NR’s well established and
• Mechanical protection (26: oil and winding temperature; 63: proven hardware platform with multi-processor architecture.
gas, pressure; 71: oil level; etc) The multi CPU technology supports the parallel operation of
CPU modules.
• Self diagnostic
• Auxiliary power supervision • The relay provides GPS clock synchronization, including
second pulse, IRIG-B and SNTP.
• Event recorder including 1024 disturbance records, 1024
binary events, 1024 supervision events and 1024 operating • The connector type is optional, one is the plug in/out terminal
logs connector and the other is the screw terminal connector. The
unique plug in/out terminal connectors are used to connect
the rear panel to the terminal blocks on the rack or cabinet,
Communication
making on-site commissioning and replacement much easier
• Two 10Base-T/100Base-TX (RJ45) ports and two optional
than using traditional screw terminals.
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
non-time-critical message, IEC 60870-5-103 over TCP/IP or • The relay is compatible with IEC 61850-8-1 MMS, GOOSE
DNP 3.0 and IEC 61850-9-2 Sampling Value and provides the
• Two RS-485 rear ports with IEC 60870-5-103 independent interfaces for station bus and process bus
respectively.

Technical data

Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage

Read more on the web


116 read more on www.nrelect.com www.nrelect.com
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 117
- Optical Fiber Port
Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I
- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV

Read more on the web


118 read more on www.nrelect.com www.nrelect.com
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 119
RCS-974
Transformer Auxiliary Relay

The RCS-974 provides auxiliary protection for transformers


including mechanical protection, pole disagreement
protection and breaker failure protection. The source of
mechanical protection can be designed from non-electrical
quantities such as gas, oil temperature, winding temperature,
pressure and oil level. It is fully compatible with IEC 61850
communication.

Features
• Seven (7) channels of mechanical quantity inputs are for
signaling. Five (5) channels of mechanical quantity inputs
are for instantaneous tripping. Three (3) channels of
mechanical quantity inputs are for tripping with time delay.

• Innovative technology to prevent any undesired trip caused


by any component failure is adopted. The relay has two
independent data acquisition paths, one for a fault detector
and the other for protection and its logic. Tripping outputs are
Functions supervised by the fault detector to prevent a mal-operation.

• The connector type can be selected as plug in/out terminal


• Mechanical protection. (26: oil and winding temperature; 63:
connector or cirmp terminal connector. The unique plug in/
gas, pressure; 71: oil level; etc)
out terminal connectors from the relay rear panel to the
• Breaker failure initiation. (50BF)
terminal blocks on the rack or cabinet makes the on-site
• Pole disagreement protection. commissioning and replacement much easier than the
• Fault and disturbance recorder. traditional screw terminals when you do the commissioning.
• 64 pieces of tripping reports. • On the premise of 24 samples per cycle, all data
• 64 pieces of alarm reports. measurement, calculation and logic discrimination could be
done within one sampling period. The event recording and
• 64 pieces of binary input status change reports.
protection logic calculation are completed simultaneously.
• High resolution oscillography of last 24 oscillograms
(Compatible with international COMTRADE format) • The relay provides GPS clock synchronization, including
message, second pulse, minute pulse and IRIG-B
• Rear communication ports: Ethernet (Optional) with IEC
synchronization.
61850 or 2 RS-485 with IEC 60870-5-103 protocol, 1 RS-
485 for clock synchronization, 1 RS-232 with printer. • The relay is compatible with multiple protocols- IEC61850
• Front communication port: 1 RS-232 for testing and setting. and IEC 60870-5-103. It provides networking interface such
as RS485, RS232, and Ethernet and optical-fiber port.

Technical data

Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008

Read more on the web


120 read more on www.nrelect.com www.nrelect.com
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Read more on the web


www.nrelect.com read more on www.nrelect.com 121
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


122 read more on www.nrelect.com www.nrelect.com
Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 123
PCS-9671
Transformer Differential Relay

The PCS-9671 is a microprocessor-based relay designed


for the protection of two-winding or three-winding power
transformers with maximum three CT inputs. It also can be
used to protect reactors or applied as an stub differential
Functions protection. The restraint current differential protection,
unrestraint differential protection and restricted earth fault
Protection and Control protection are provided.
• Restraint current differential protection. (87T)
Two stages with low-setting and high-setting are provided for The relay is capable of sampling the analog signals from
this protection. And the low-setting stage could be blocked conventional transformers, or receiving the sampled values
by CT saturation, inrush current, overexcitation and CT from electronic CTs/VTs via merging units. The programmable
circuit failure. As well the high-setting stage could be blocked logic, LEDs, binary inputs and outputs can be configured
by inrush current and CT circuit failure. according to the specific requirements through software tool.
It provides the interfaces for station bus and process bus
• Unrestraint current differential protection. (50/87UT) respectively and supports IEC 61850-8-1 MMS, GOOSE, IEC
It is used to clear the serious internal fault quickly. 61850-9-2 Sampling Value.

• Restricted earth fault protection. (REF)


Up to 3 REF protections based on zero-sequence current
differential element are provided.

• Phase overcurrent protection for each side.(50/51P) Management


Up to 3 overcurrent protections are provided. • 64 protection operation reports, 1024 supervision alarm
records, 1024 control operation records and 1024 user
• Mechanical protection. (MT) operation records.
Up to 8 mechanical channels are provided. • 64 Fault and disturbance records.
• 1024 latest SOE records, latest records of the following
• CT circuit supervision. (CTS)
elements state changing.
CT circuit supervision consists of two elements: CT circuit
abnormality without fault detector pickup and CT circuit • Up to four 10Base-T/100Base-TX (RJ45) ports or two
failure with fault detector pickup. 100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
non-time-critical message, IEC 60870-5-103 over TCP/IP or
• Inrush current blocking by 2nd harmonic. DNP 3.0
Phase-segregated blocking, cross blocking and composited • Two RS-485 rear ports with IEC 60870-5-103
blocking are provided for selection. • Up to Six 100Base-FX ports with IEC 61850-9-2 Sampling
Value and GOOSE for time-critical message
• Overexcitation blocking by 5th harmonic.
• One RS-485 rear port for clock synchronization
Overexcitation is detected via the ratio of 5th harmonic
current and fundamental current. • One RS-232 rear port for printer
• 1 faceplate RJ45 port for testing and setting
• CT saturation detection • Clock synchronization via pulse, IRIG-B and SNTP
CT saturation is distinguished via composited 2nd and 3rd
harmonics.
Auxiliary Testing Functions
• Virtual tripping report generation and communication testing
• Virtual self-supervision report generation and communication
testing.
• Virtual binary input state change report generation and
communication testing.
• Binary output testing.
• Manual triggering fault recording.

Read more on the web


124 read more on www.nrelect.com www.nrelect.com
Features • Powerful fault and disturbance recording function is
supported: 64 latest fault or disturbance waves, the duration
of a wave recording is configurable.
• This device is designed based on 32-bit high performance
dual-core processor, internal high speed bus and intelligent • Wye→Delta transfer method is used to compensate phase
I/O ports. The hardware adopts module design and can be angle of secondary current, and correction coefficients are
configured flexibly. adopted to complete amplitude compensation.
• The unique hardware design with two independent data • Vector group of each side transformer is settable, and 24
acquisition paths can prevent the maloperation due to the vector groups available for two-winding transformer, and 288
hardware component failure. It will significantly enhance the vector groups available for 3-winding transformer.
reliability.
• Unrestraint instantaneous differential protection does not be
• This device can sample the analog values from conventional blocked by any condition to ensure fast tripping in case of
transformers, or receive the sampled values from electronic serious faults inside transformer.
CT/VT. It supports IEC60044-8, IEC61850-9-2 and GOOSE.
• Three slopes biased differential protection is adopted to
• Various methods of GPS time synchronization are supported avoid mal-operation caused by unbalance current during
in this relay, including SNTP, IEEE1588 (V2), pulse per external fault.
second (PPS) and IRIG-B synchronization.
• 2nd , 3rd and 5th harmonic blocking function for biased
• The device can communicate with SAS or RTU via different differential protection is available. 2nd harmonic and 3rd
communication intermediates: Ethernet network, RS-485 harmonic is selectable to identify inrush current, and 5th
serial ports. The communication protocol of this device is harmonic is used to detect overexcitation condition. Besides,
optional: IEC61850, IEC60870-5-103 or DNP3.0. phase segregated blocking mode or crossing blocking mode
is selectable.
• Complete event recording function is provided: 64 latest
protection operation reports, 1024 latest supervision, 1024 • CT transient detection element based on the ratio of
latest control operation records, 1024 latest user operation residual current to positive current is adopted to eliminate
records and 1024 latest records of time tagged sequence of the influence on REF due to the CT transient characteristic
event (SOE) can be recorded. difference.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<10W (for conventional substation application)
Quiescent condition
<15W (for smart substation application)
Burden
<15W (for conventional substation application)
Operating condition
<20W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Application object For protection For metering
Rated current (In) 1A 5A 1A 5A
Linear to 30In 30In 2In 2In
continuously 3In 3In 2In 2In
for 10s 30In 30In 12In 12In
Thermal withstand capability
for 1s 100In 100In 30In 30In
for half a cycle 250In 250In 75In 75In
Burden <0.1VA/phase <0.2VA/phase <0.2VA/phase <0.4VA/phase

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 48V 110V 125V 220V 250V
Rated current 1.2mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 55% rated voltage
Maximum permissive voltage 120% rated voltage
Withstand 2000Vac, 2800Vdc
Resolving time for logic input <1ms
Read more on the web
www.nrelect.com read more on www.nrelect.com 125
Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
Max system voltage 380Vac, 250Vdc 380Vac, 250Vdc
Voltage across open contact 1000V RMS for 1 minute 1200V RMS for 1 minute
5.0A @ 380Vac 8.0A @ 380Vac
Continuous carry
5.0A @ 250Vdc 8.0A @ 250Vdc
Pickup time <8ms <10ms
Drop-off time <5ms <8ms
6A for 3000ms 10A for 3000ms
Short duration current
15A for 500ms 20A for 500ms
0.6A @ 48Vdc, L/R=40ms 0.6A @ 48Vdc, L/R=40ms
Breaking capacity (L/R=40ms) 0.1A @ 110Vdc, L/R=40ms 0.3A @ 110Vdc, L/R=40ms
0.05A @ 220Vdc, L/R=40ms 0.2A @ 220Vdc, L/R=40ms
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 225.00×177.00×224.80 (unit: mm)
Trepanning dimensions (W×H) 226.00×178.00, M5 screw (unit: mm)
Mounting Flush mounted
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- Serial Port for RTU/SCADA
Port number 0 or 2
Baud rate 4800 ~ 115200bps
Protocol IEC60870-5-103:1997 or DNP3.0
Maximal capacity 32
Transmission distance <1000m @ 4800bps
Safety level Isolation to ELV level

- Ethernet Port for RTU/SCADA


Medium Parameters
Port number 2 or 4
Connector type RJ-45
Transmission rate 100Mbits/s
Ethernet Electrical Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Ethernet Optical
Optical fiber type Multi-mode
Wavelength 1300
Transmission distance <1500
Protocol IEC60870-5-103:1997 or IEC61850

- Process Level Interface


Characteristic Glass optical fiber
Optical fiber type Multi-mode
Connector type LC ST
Wave length 820nm 1310nm

Read more on the web


126 read more on www.nrelect.com www.nrelect.com
Transmission distance <2000m
Minimum transmission power -20dBm
Reception sensitivity -30dBm

- Print Port
Port number 1
Type RS-232
Baud Rate 4800 ~ 115200bps
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Port number 1
Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 127
RCS-9671
Transformer Differential Relay

The RCS-9671 is a microprocessor-based relay designed


for the protection of two-winding or three-winding power
transformers with maximum four CT inputs. The protection
relay is recommended to be applied to power transformers,
short feeders or reactors.

The percentage restraint differential protection and


instantaneous differential protection are the main protection
elements of RCS-9671.

Features
• The typical operating time of unrestraint current differential
protection is 35ms.

• The percentage restraint differential element and unrestraint


current differential elements are provided as the main
protection of transformer.

• Current differential protection could be supervised by second


Functions harmonics to distinguish inrush current.

• The ratio of CT on each side can be different. Different ratio


• Unrestraint current differential protection. (87UT)
of various CT on each side can be regulated by configurable
• Percentage restraint current differential protection. (87PT) parameters in the relay.
• Phase overcurrent protection for each side.(50P/51P)
• Various transformer and CT connection types at each side
• Neutral overcurrent protection for each side. (50/51N) can be compensated by configuring logic settings in the
• Inrush current detection. relay.
• Restricted earth fault protection for each side.(REF) • On the premise of 24 samples per cycle, all data
• 2nd harmonic blocking for differential protection. measurement, calculation and logic discrimination can be
• CT circuit failure supervision.(CTS) finished within one sampling period. The event recording and
protection logic calculation are completed simultaneously.
• Self diagnostic.
• GPS clock synchronization. • The relay provides GPS clock synchronization, including
message, second pulse and IRIG-B synchronization.
• Fault recorder.
• 64 tripping reports and 256 SOE(Sequence of Events) • The relay is equipped with Ethernet ports with the IEC 61850
records. protocol and RS-485 ports with IEC 60870-5-103 protocol.

• High resolution oscillography of last 8 oscillograms


(Compatible with international COMTRADE format)
• Rear communication ports: Ethernet with IEC 61850,
2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.
• Optional OPT-103 E/O converter module for optical
communication with SCADA.

Read more on the web


128 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted

Read more on the web


www.nrelect.com read more on www.nrelect.com 129
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns

Read more on the web


130 read more on www.nrelect.com www.nrelect.com
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 131
RCS-9679
Transformer Protection

TThe RCS-9679 relay is a microprocessor-based relay


designed for the protection of two-winding power transformers
with various kinds of connect groups. Up to three CT inputs
can be provided.

• Self diagnostic.
• Fault and disturbance recorder.
• Rear communication ports: Ethernet with IEC 61850,
2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.

Features
• The typical operating time of unrestraint current differential
protection is 35ms.

• Current differential protection could be supervised by second


harmonics to distinguish inrush current.

• The ratio of CT on each side could be different. Different


Functions ratio of various CT on each side could be regulated by
configurable parameters in software.
• Unrestraint current differential protection. (87UT)
• Various transformer and CT connection types at each side
• Percentage restraint current differential protection. (87PT) could be compensated by configuring logic setting in the
• Second harmonic blocking for differential protection. relay.
• Three-stage voltage controlled overcurrent protection for HV • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
side. (50P/51P) measurement, calculation and logic discrimination can be
• Three-stage voltage controlled overcurrent protection for LV finished within one sampling period. The event recording and
side. (50P/51P) protection logic calculation are completed simultaneously.
• Zero sequence overvoltage protection. (50N/51N) • The relay provides GPS clock synchronization, including
• Thermal overload protection. (49) message, second pulse and IRIG-B synchronization.
• Overload initiating cooling function. (49) • The relay can communication with SAS or RTU based on
• Blocking OLTC (on-load tap change) function during IEC 61850 and IEC60870-5-103.
overload. (49)
• Fault and disturbance recording function: 64 latest tripping
• Restricted earth fault protection. (REF) records, 8 latest fault wave (up to 15s), 64 latest equipment
• Zero sequence overvoltage alarm function. (59N) self-check alarm records, 64 latest alarm records of
• 8 (up to 10) channels of mechanical protection. (MR) equipment operating abnormality, 64 user operating records
and 256 records of time-tagged sequence of event can be
• Remote control and measurements.
recorded.
• VT circuit failure supervision.(VTS)
• CT circuit failure supervision.(CTS)
• Tripping circuit supervision.

Read more on the web


132 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 284.2×266.0×203.0 (unit: mm)
Trepanning dimension (W×H) 296.2×268.0, M5 screw
Mounting Flush mounted

Read more on the web


www.nrelect.com read more on www.nrelect.com 133
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns

Read more on the web


134 read more on www.nrelect.com www.nrelect.com
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 135
RCS-9681
Transformer Overcurrent Relay

The RCS-9681 is a digital protection, control and monitoring


unit for power transformer in solidly grounded, impedance
grounded, Peterson coil grounded and ungrounded system.
It provides complete backup protection of each side of
power transformer. It is fully compatible with IEC 61850
communication.

• Current drift auto adjustment.


• Self diagnostic.
• GPS clock synchronization.
• Fault and disturbance recorder.
• 64 tripping reports and 256 SOE (Sequence of Events)
records.
• Rear communication ports: Ethernet port for IEC 61850,
2 RS-485 port for IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.

Functions Features
• Voltage controlled directional phase overcurrent protection. • The overcurrent protection can be supervised by voltage
(67P) control elements.

• Voltage controlled phase overcurrent protection. (50P/51P) • The overvoltage protection can be supervised by zero
• Directional neutral overcurrent protection. (67N) sequence current element.

• Neutral overcurrent protection. (50N/51N) • The RCS-9681 relay constantly measures a large amount
• Ground overcurrent protection. (50G/51G) of analog quantities, such as phase voltage, phase-to-
phase voltage, zero sequence voltage, phase current, zero
• Ground overvoltage protection. (59G)
sequence current, active power, reactive power, power factor
• Over excitation protection. (24) and frequency.
• Thermal overload protection. (49)
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Cooler initiation function during overload. (49) measurement, calculation and logic discrimination can be
• On-load-tap-change (OLTC) blocking function during finished within one sampling period. The event recording and
overload. (49) protection logic calculation are completed simultaneously.
• Remote control and measurements. • The relay provides GPS clock synchronization, including
• CT circuit failure supervision. (CTS) message, second pulse and IRIG-B synchronization.
• VT circuit failure supervision. (VTS) • The format of event report is compatible with international
• Tripping circuit supervision. COMTRADE file.

Read more on the web


136 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted

Read more on the web


www.nrelect.com read more on www.nrelect.com 137
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns

Read more on the web


138 read more on www.nrelect.com www.nrelect.com
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 139
RCS-9621
Transformer Management Relay

The RCS-9621 transformer management relay provides fast


and selective short-circuit protection, control and monitoring
of transformers(substation-used or grounding transformers) in
impedance grounded, Peterson coil grounded or ungrounded
system. The relay is suited to be flush mounted into a control
panel.

• GPS clock synchronization.


• Fault and disturbance recorder.
• 64 tripping reports and 256 SOE (Sequence of Events)
records.
• High resolution oscillography of last 8 oscillograms
(compatible with international COMTRADE format)
• Rear communication ports: Ethernet with IEC 61850,
2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.

Features
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
measurement, calculation and logic discrimination can be
finished within one sampling period. The event recording and
Functions protection logic calculation are completed simultaneously.

• Three-stage voltage controlled overcurrent protection. • Overcurrent protection can be supervised by voltage control
(50P/51P) elements.
• Two- stage negative sequence overcurrent protection. • Definite time of negative sequence overcurrent protection is
(50Q/51Q) provided for high voltage side of the transformer.
• Three-stage zero sequence overcurrent protection for HV
side. (50N/51N) • Definite time and inverse time of negative sequence
• Three-stage zero sequence overcurrent protection for LV overcurrent protection are both provided for the low voltage
side. (50N/51N) side of transformer.
• Ground overcurrent protection for HV side. (50/51G) • The RCS-9621 relay constantly measures a large amount
• Ground overvoltage protection for HV side. (59G) of analog quantities, such as phase voltage, phase-to-
• Under voltage protection. (27) phase voltage, zero-sequence voltage, phase current, zero-
• Mechanical protection. (26: oil and winding temperature; 63: sequence current, active power, reactive power, power factor
gas, pressure; 71: oil level; etc) and frequency.
• Thermal overload protection. (49) • The relay can monitor the status of the circuit breaker.
• Remote control and measurement
• CT circuit failure supervision. (CTS) • The relay provides GPS clock synchronization, including
• VT circuit failure supervision.(VTS) message, second pulse and IRIG-B synchronization.
• Tripping circuit supervision. • The relay is equipped with Ethernet ports with the IEC 61850
• Voltage and current drift auto adjustment. protocol and RS-485 ports with IEC 60870-5-103 protocol.
• Self diagnostict.

Read more on the web


140 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs:
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted

Read more on the web


www.nrelect.com read more on www.nrelect.com 141
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns

Read more on the web


142 read more on www.nrelect.com www.nrelect.com
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 143
RCS-9661
Transformer Auxiliary Relay

The RCS-9661 is a transformer auxiliary relay, which provides


mechanical protection and relay paralleling or switchover
functions (optional). The signals of mechanical protection
can be configured from non-electrical quantities, such as gas
signal, oil over-temperature signal, winding over-temperature
signal, pressure signal and oil level signal etc.

2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock


synchronization, 1 RS-232 for communication to printer.

Features
• On the premise of 24 samples per cycle, all data
measurement, calculation and logic discrimination can be
done within one sampling period. The event recording and
protection logic calculation are completed simultaneously.
Functions • Power supply of mechanical quantity input circuit is
monitored.
• Mechanical protection. (26: oil and winding temperature; 63:
gas, pressure; 71: oil level; etc) • Mechanical protection and other auxiliary relay circuit are
• 8 (up to 12 by configuring No.9 IO module) channels of independent to each other.
mechanical quantity input are provided for trip or alarm. • The relay provides GPS clock synchronization, including
• Voltage switchover relays message, second pulse and IRIG-B synchronization.
• Remote control and measurement • The relay is equipped with two EIA RS-485 standardized
• AC voltage auto-switching function. interfaces and two Ethernet interfaces. The Ethernet
• Tripping circuit supervision. interfaces are optional: electrical or optical.

• Self diagnostic. • The relay is compatible with IEC 61850 protocol and IEC
• GPS clock synchronization. 60870-5-103 protocol.

• Fault and disturbance recorder. • Fault and disturbance recording function: 64 latest tripping
• 64 tripping reports and 256 SOE (Sequence of Events) records, 6 latest fault wave (up to 15s), 64 latest equipment
records. self-check alarm records, 64 latest alarm records of
equipment operating abnormality, 64 user operating records
• Rear communication ports: Ethernet with IEC 61850,
and 256 records of time-tagged sequence of event can be
recorded.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11

Read more on the web


144 read more on www.nrelect.com www.nrelect.com
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 284.2×266.0×203 (unit: mm)
Trepanning dimensions (W×H) 296.2×268.0, M5 screw
Mounting Flush mounted
Front side: IP40, up to IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +60°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Ethernet Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Connector type SC
Optical
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX

Read more on the web


www.nrelect.com read more on www.nrelect.com 145
Optical Fiber Type Multi-mode
Wavelength 1300nm
Ethernet Optical Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


146 read more on www.nrelect.com www.nrelect.com
RCS-9622
Transformer Management Relay

The RCS-9622 transformer management relay is designed


for the fast and selective short-circuit protection, control and
monitoring of transformers (substation-used or grounding
transformers) in impedance grounded or Peterson coil
grounded or ungrounded- system. The relay is suited to be
flush mounted into a control panel.

Management
• Circuit breaker status monitoring.
• Remote control and measurements.
• Tripping/Closing circuit supervision.
• Multiple setting groups.
• 64 Trip records.
• 64 Self-check alarm records.
• 64 Operating alarm records.
• 64 User operating records.
• 8 Disturbance records FR.
• 256 SOE records, latest records of following elements state
changing: operating abnormality alarm elements, self-check
alarm elements, protection elements, binary input elements
• Circuit breaker operating time monitoring.

Auxiliary Testing
Functions • Virtual SOE records generation.

Protection and control • Virtual measurement values generation.

• Current differential protection. (87T) • Virtual tripping reports generation.

• Unrestrained current differential protection. (87UT) • Virtual fault wave records generation.

• Zero-sequence differential current protection. (87GT)


• Non-directional overcurrent protection. (50P/51P)
• Time zero sequence overcurrent protection. (50N) Features
• Negative sequence overcurrent protection. (51Q)
• On the premise of 24 samples per cycle, all data
• Voltage control element. (VCE)
measurement, calculation and logic discrimination can be
• Earth fault protection. (64) finished within one sampling period. The event recording and
• Thermal overload supervision. (49) protection logic calculation can be finished simultaneously.
• Mechanical protection. (MR) • Definite time and inverse time of overcurrent protection are
• Voltage and current drift auto adjustment. both provided.
• Self diagnostic. • Definite time of negative sequence overcurrent protection is
• Voltage transformer supervision. (VTS) provided for the high voltage side of transformer.
• Current transformer supervision. (CTS) • Definite time and inverse time of negative sequence
• Rear communication ports: printer. overcurrent protection are both provided for the low voltage
• Rear communication ports: RS-485/Ethernet. side of transformer.

• Time synchronization port. • Overcurrent protection can be controlled by voltage element.

Read more on the web


www.nrelect.com read more on www.nrelect.com 147
• It constantly measures and calculates a large amount of • It is equipped with two EIA RS-485 standardized interfaces
analog quantities, such as phase-to-phase voltage, phase and two Ethernet interfaces. Two alternative designs of
current, neutral current, active power, reactive power, power Ethernet interfaces are provided: electrical or optical.
factor and frequency.
• It can communicate with SAS or RTU using IEC60870-5-103
• It can monitor and record the operating times of opening/ and MODBUS communication protocols.
closing circuit breakers.
• Fault and disturbance record function: 64 latest fault reports,
• Multiple GPS clock synchronization, including message, 8 latest fault wave (up to 15s), 64 user operating records
pulse per second, and IRIG-B synchronization. of users to equipment, and 256 records of time tagged
sequence of event can be recorded.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6, 1988
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs:
Rated Voltage 110VDC 220VDC 125VDC 250VDC
Pickup voltage 77VDC 154VDC 87.5VDC 175VDC
Dropout voltage 60.5VDC 121VDC 68.8VDC 137.5VDC
Maximum permitted voltage 150V 300V 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000Vac rms for 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
Dropout time(Typical/Max) 8ms/10ms 4ms/10ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Read more on the web


148 read more on www.nrelect.com www.nrelect.com
DC Output
Output range 4 ~ 20mA
Max load resistance 500ohm
Max output voltage 10V

Atmospheric Environment
Standard IEC60255-6:1988
Operating temperature range -25 °C ~ +55 °C
Transport and storage temperature range -40 °C ~ +70 °C
Permissible humidity 5% ~ 95%, condensation not permissible

Mechanical Specifications
Enclosure dimensions (W×H×D) 142.4×266.0×203.0 (unit: mm)
Trepanning dimensions (W×H) 154×268.0 (unit: mm), M5 screw
Mounting Way Flush mounted
Local control panel Small control module: 3 LED indicators, a 9-key keypad and a 160×80-dot LCD
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Ethernet
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Optical Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Fiber Type Multi-mode
Wavelength 1300nm
Ethernet Optical
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 149
Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2007 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz /450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2008 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m for 1 minute
1000A/m for 3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:1974, 16 hours at +55°C
Dry cold test IEC60068-2-1:1990, 16 hours at -25°C
IEC60068-2-30:1980, two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


150 read more on www.nrelect.com www.nrelect.com
RCS-9624
Transformer Management Relay

The RCS-9624 transformer management relay is designed


for fast and selective short-circuit protection, control and
monitoring of transformers (substation-used or grounding
transformers) in impedance grounded or Peterson coil
grounded or ungrounded system. The relay is suited to be
flush mounted into a control panel.

• Multiple setting groups.


• 64 Trip records.
• 64 Self-check alarm records.
• 64 Operating alarm records.
• 64 User operating records.
• 8 Disturbance records FR
• 256 SOE records, latest records of following elements state
changing: operating abnormality alarm elements, self-check
alarm elements, protection elements, binary input elements
• Circuit breaker operating time monitoring.

Auxiliary Testing
• Virtual SOE records generation
Functions • Virtual measurement values generation
• Virtual tripping reports generation
Protection and control
• Virtual fault wave records generation
• Non-directional overcurrent protection. (50P/51P)
• Non-directional earth fault protection. (50G/51G)
• Instantaneous zero sequence overcurrent protection. (50N)
• Negative sequence overcurrent protection. (51Q) Features
• Voltage controlled element. (VCE) • On the premise of 24 samples per cycle, all data
• Earth fault protection. (64) measurement, calculation and logic discrimination can be
finished within one sampling period. The event recording and
• Thermal overload supervision. (49)
protection logic calculation can be completed simultaneously.
• Mechanical protection. (MR)
• Definite time and inverse time of overcurrent protection are
• Voltage and current drift auto adjustment.
both provided.
• Self diagnostic.
• Definite time of negative sequence overcurrent protection is
• Voltage transformer supervision. (VTS)
provided for high voltage side of transformer.
• Current transformer supervision. (CTS)
• Definite time and inverse time of negative sequence
• Rear communication ports: printer.
overcurrent protection are both provided for low voltage side
• Rear communication ports: RS-485.
of transformer.
• Time synchronization port.
• Overcurrent protection can be controlled by voltage element.
Management • It constantly measures and calculates a large mount of
• Circuit breaker status monitoring. analog quantities, such as phase-to-phase voltage, phase
• Remote control and measurements. current, neutral current, active power, reactive power, power
• Tripping circuit supervision. factor and frequency.

Read more on the web


www.nrelect.com read more on www.nrelect.com 151
• It can monitor and record the operating times of opening/ • It can communicate with SAS or RTU using IEC60870-5-103
closing circuit breakers. and MODBUS communication protocols.

• Multiple GPS clock synchronization, including message, • Fault and disturbance record function: 64 latest fault reports,
pulse per second, and IRIG-B synchronization. 8 latest fault wave (up to 15s), 64 user operating records
of users to equipment, and 256 records of time tagged
• This relay is equipped with two EIA RS-485 standardized
sequence of event can be recorded.
interfaces and two Ethernet interfaces. Two alternative
designs of Ethernet interfaces are provided: electrical or
optical.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6, 1988
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Input
Rated Voltage 110VDC 220VDC 125VDC 250VDC
Pickup voltage 77VDC 154VDC 87.5VDC 175VDC
Dropout voltage 60.5VDC 121VDC 68.8VDC 137.5VDC
Maximum permitted voltage 150V 300V 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000Vac rms for 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
Dropout time(Typical/Max) 8ms/10ms 4ms/10ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Read more on the web


152 read more on www.nrelect.com www.nrelect.com
DC Output
Output range 4 ~ 20mA
Max load resistance 500ohm
Max output voltage 10V

Atmospheric Environment
Standard IEC60255-6:1988
Operating temperature range -25 °C ~ +55 °C
Transport and storage temperature range -40 °C ~ +70 °C
Permissible humidity 5% ~ 95%, condensation not permissible

Mechanical Specifications
Enclosure dimensions (W×H×D) 142.4×266.0×203.0 (unit: mm)
Trepanning dimensions (W×H) 154×268.0 (unit: mm), M5 screw
Mounting Way Flush mounted
Local control panel Small control module: 3 LED indicators, a 9-key keypad and a 160×80-dot LCD
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Ethernet
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Optical Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Fiber Type Multi-mode
Wavelength 1300nm
Ethernet Optical
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 153
Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2007 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz /450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2008 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m for 1 minute
1000A/m for 3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:1974, 16 hours at +55°C
Dry cold test IEC60068-2-1:1990, 16 hours at -25°C
IEC60068-2-30:1980, two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


154 read more on www.nrelect.com www.nrelect.com
Reactor Protection
Reactor Protection Applications
How our products provide reliable, fast and accurate protection through our patented techniques are described in this section. Technical
data of different devices are provided in each relaying description.

Function Index

Functional
Function RCS-917 RCS-9647
Code
Main protection
Unrestraint current differential protection 87U √ √
Percentage current differential protection 87P √ √
DPFC current differential protection 87D √
Zero sequence current differential protection REF √
Inter-turn fault protection √
Back-up protection
Phase overcurrent protection 50P, 51P √ √
Zero sequence overcurrent protection 50N, 51N √ √
Ground overcurrent protection 50G, 51G √
Thermal overload protection 49 √ √
Miscellaneous
Mechanical protection √ √
CT circuit failure supervision CTS √
VT circuit failure supervision VTS √
Tripping/Closing circuit supervision TCS/CCS √
GPS clock synchronization √ √
Remote control √
Analog quantity measurements √
Fault and disturbance recorder √ √
Self diagnostic test √ √
Voltage and current drift auto adjustment √ √
IEC 60870-5-103 protocol √ √
IEC 61850 protocol √ √

Read more on the web


www.nrelect.com read more on www.nrelect.com 155
RCS-917
Reactor Protection

The RCS-917 relay is used for the main and back-up


protection and mechanical protection of shunt reactors. It is
fully compatible with IEC 61850 communication.

• 64 pieces of binary input status change reports.


• Rear communication ports: Ethernet (Optional) with IEC
61850, 2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.
• Front communication port: 1 RS-232 for testing and setting.

Features
• Main and backup protections are integrated in one set
of protection equipment. Protection information such as
sampled data and binary inputs are shared by all elements.

• The DPFC percentage differential protection is immune to


Functions load current but sensitive to small internal fault current within
the reactor.
• Percentage restraint differential protection. (87R)
• The patented adaptive floating threshold method is adopted,
• Unrestrained instantaneous differential protection. (87UR)
which is immune to system unbalance and disturbance.
• DPFC (Deviation Power Frequency Variation Component) The measuring element can get both high security and high
current differential protection. (7/87DR) speed simultaneously.
• Zero sequence current differential protection. (87NR)
• Innovative technology to prevent any undesired trip caused
• Inter-turn fault protection. (32G/21G) by any component failure is adopted. The relay has two
• Two-stage definite time and one-stage inverse time independent data acquisition paths, one for a fault detector
overcurrent protection. (50P/51P) and the other for protection and its logic. Tripping outputs
• Two-stage overcurrent protection for grounded reactor. (50G are supervised by the fault detector to prevent any mal-
/51G) operation.

• Two-stage zero sequence overcurrent protection. (50N/51N) • The connector type can be selected as plug in/out terminal
• Thermal overload protection. (49) connector or crimp terminal connector. The unique plug in/
out terminal connectors from the relay rear panel to the
• Thermal overload protection for grounded reactor. (49G)
terminal blocks on the rack or cabinet makes the on-site
• Mechanical protection. commissioning and replacement much easier than the
• CT circuit failure supervision. (VTS) traditional screw terminals when you do the commissioning.
• VT circuit failure supervision. (CTS) • On the premise of 24 samples per cycle, all data
• Voltage and current drift auto adjustment. measurement, calculation and logic discrimination can be
• Self diagnostic. finished within one sampling period. The event recording and
protection logic calculation are completed simultaneously.
• Fault and disturbance recorder.
• GPS clock synchronization. • The relay provides GPS clock synchronization, including
message, second pulse, minute pulse and IRIG-B
• 64 pieces of tripping reports
synchronization.
• 64 pieces of alarm reports
• The relay is compatible with multiple protocols- IEC61850
and IEC 60870-5-103. It provides networking interface such
as RS485, RS232 Ethernet and optical-fiber port.

Read more on the web


156 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Read more on the web


www.nrelect.com read more on www.nrelect.com 157
Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Temperature range -5°C ~+55°C -5°C ~+55°C
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

Read more on the web


158 read more on www.nrelect.com www.nrelect.com
- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 159
RCS-9647
Reactor Management Relay

The RCS-9647 reactor management relay is designed for


fast and selective protection, control and monitoring of
reactors in impedance grounded or Peterson coil grounded
or ungrounded system.

• Self diagnostic.
• GPS clock synchronization.
• Fault and disturbance recorder.
• 64 tripping reports and 256 SOE (Sequence of Events)
records.
• High resolution oscillography of last 8 oscillograms
(compatible with international COMTRADE format)
• Rear communication ports: 2 Ethernet interfaces with IEC
61850, 2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.

Features
• Definite time and inverse time characteristics of overcurrent
and zero sequence overcurrent protections are both provided
respectively.

Functions • The RCS-9647 relay constantly measures a large amount of


analog quantities, such as phase voltage, phase-to-phase
• Unrestraint current differential protection. (87UR) voltage, phase current, active power, reactive power, power
factor and frequency.
• Percentage current differential protection. (87PR)
• Two-stage definite time overcurrent protection and one-stage • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
inverse definite time overcurrent protection. (50P/51P) measurement, calculation and logic discrimination could be
done within one sampling period. The event recording and
• Two-stage zero sequence overcurrent protection and one
protection logic calculation are completed simultaneously.
stage can be configured as inverse definite time overcurrent
protection. (50N/51N) • The relay provides GPS clock synchronization, including
• 6 channels of mechanical quantity protection. (MR) message, second pulse and IRIG-B synchronization.

• Thermal overload protection. (49) • This relay can communication with SAS or RTU using IEC
• Remote control and measurements. 61850 and IEC60870-5-103.

• CT circuit failure supervision.(CTS) • The format of event report is compatible with international
• VT circuit failure supervision.(VTS) COMTRADE file.

• Tripping circuit supervision. • The relay is equipped with Ethernet ports with the IEC 61850
• Voltage and current drift auto adjustment. protocol and RS-485 ports with IEC 60870-5-103 protocol.

Read more on the web


160 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted

Read more on the web


www.nrelect.com read more on www.nrelect.com 161
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns

Read more on the web


162 read more on www.nrelect.com www.nrelect.com
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 163
Circuit Breaker Protection
Circuit Breaker Protection Applications
How our Circuit Breaker Protection products provide reliable, fast and accurate protection through our patented techniques are described in this
section. Technical data of different devices are provided in each relaying description.

Function Index

Function Functional Code PCS-921 RCS-921 RCS-923

Phase overcurrent protection 50P/51P √ √


Zero sequence overcurrent protection 50N/51N √ √
Breaker failure protection 50BF √ √ √
Energizing protection 50E √ √
Dead zone protection 50D √ √
Pole discrepancy protection √ √ √
Synchronism check 25 √ √ √
Auto-reclosing function 79 √ √ √
CT failure supervision CTS √
VT failure supervision VTS √ √ √
Circuit breaker monitoring √ √ √
GPS clock synchronization √ √ √
Fault Recorder FR √ √ √
IEC61850-8-1 MMS & GOOSE for station bus √ √ √
IEC61850-9-2 SV & IEC61850-8-1 GOOSE for process bus √
IEC60870-5-103 protocol √ √ √
IEC61850 protocol √

164 read more on www.nrelect.com


PCS-921
Circuit Breaker Protection

The PCS-921 numerical relay provides the protection


of circuit breakers with breaker failure protection, pole
discrepancy protection, dead zone protection, phase/
neutral overcurrent protection, single and/or three-pole
auto-reclosing and synchronism check functions. The PCS-
921 relay employs the programmable logic, configurable I/
O and definable 3-color LEDs to provide flexibility for the
specific applications. Frequency tracking is used to minimize
the sampling error caused by system frequency fluctuation.
The PCS-921 relay adopts the advanced multi-processor
platform, providing the interfaces to station bus and process
bus respectively and supporting IEC 61850-8-1 MMS,
GOOSE, IEC 61850-9-2 Sampling Value. In addition, RJ-45
faceplate port for testing and setting to make commissioning
and maintenance easier.

Second harmonic element could be selected to block the


neutral overcurrent element.

• Synchronism check (25)


The criteria could be set as frequency difference, voltage
Functions difference, and phase angle difference. And the checking
condition could be selected as live-bus to dead-line, dead-
Protection and Control bus to live-line or dead-bus to dead-line.

• Breaker failure protection (50BF) • Single and/or three-pole auto-reclosing (79)


Re-tripping the own breaker and tripping the adjacent Up to 4 shots could be selected for the single-/three- pole
breakers will be issued if the external tripping command is auto-reclosing.
received but the overcurrent element does not drop off. To
improve the sensitivity of generator/transformer protection, • Voltage and current drift auto adjustment
the neutral and negative-sequence overcurrent elements are The relay continually and automatically traces the voltage
provided besides phase overcurrent element. and current drifts and adjusts the zero point.

• Pole discrepancy protection (62PD) • Frequency tracking


The pole discrepancy is detected using the breaker auxiliary Frequency tracking is provided to accommodate the
contacts, and the asymmetrical current element could be frequency shift in power system.
selected as an additional criteria.

• Dead zone protection (50DZ) Monitoring and Measurement


The adjacent breakers will be tripped if the fault between CT • VT circuit supervision (VTS)
and breaker (dead zone) is detected via the initiating binary
• CT circuit supervision (CTS)
input from external protection, breaker auxiliary contacts and
overcurrent element. • Self diagnostic
• Auxiliary power supervision
• Two stages of phase overcurrent protection (50/51P) • Event recorder including 1024 disturbance records, 1024
Second harmonic element could be selected to block the binary events, 1024 supervision events and 1024 operating
overcurrent element to avoid the maloperation due to logs
transformer inrush current.
• Disturbance recorder including 64 disturbance records
with waveforms (The file format of disturbance recorder is
• Two stages of neutral overcurrent protection (50/51N)
compatible with international COMTRADE file.)

read more on www.nrelect.com 165


• Counter of circuit breaker operation (single-pole tripping,
three-pole tripping and reclosing)
Features
• The relay is based on NR’s well established and proven
UAPC hardware platform with multi-processor architecture.
Communication The multi CPU technology supports parallel operating
• Two 10Base-T/100Base-TX (RJ45) ports and two optional simultaneously.
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for • The two independent data acquisition paths can prevent any
non-time-critical message, IEC 60870-5-103 over TCP/IP or undesired trip caused by component failure. One works as a
DNP 3.0 fault detector and the other is designed for protection and its
• Two RS-485 rear ports with IEC 60870-5-103 logic. Tripping outputs are supervised by the fault detector to
• Six or Eight 100Base-FX ports with IEC 61850-9-2 Sampling prevent a mal-operation.
Value and GOOSE for time-critical message • The sensitive DPFC fault detector element is integrated to
• One RS-485 rear port for clock synchronization target on the quick response to short-circuit fault.
• One RS-232 rear port for printer • The relay is compatible with IEC 61850-8-1 MMS, GOOSE
• One faceplate RJ45 port for testing and setting and IEC 61850-9-2 Sampling Value and provides the
• Clock synchronization via Pulse-Per-Second, IRIG-B and independent interfaces for station bus and process bus
SNTP respectively.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V

Read more on the web


166 read more on www.nrelect.com www.nrelect.com
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm

Read more on the web


www.nrelect.com read more on www.nrelect.com 167
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


168 read more on www.nrelect.com www.nrelect.com
RCS-921
Breaker Failure Protection

The RCS-921 relay is a breaker failure relay with automatic


reclosing used for the protection of circuit breakers in all
kinds of busbar arrangement. It integrates breaker failure
protection, overcurrent protection, pole discrepancy protection
and automatic reclosing function.

• 1 RS-232 communication faceplate port for testing and


setting
• 1 RS-232 communication rear ports for printer

Features
• High-performance hardware platform and modularized
design(MCU+DSP). MCU manages general fault detector
element and DSP manages protection and metering.
The data acquisition system is completely independent
Functions of electronic circuit. The DC power supply of output relay
is switched on only if the general fault detector element
• Breaker failure protection (50) operates so as to avoid maloperation resulting from damage
• Pole discrepancy protection (52) of any apparatus.

• Two stages overcurrent protection (67P) • Up to 0.01Hz accurate frequency metering, wide range of
• Two stages zero-sequence overcurrent protection (67G) frequency tracing. Frequency can be accurately traced within
the range of 40Hz~65Hz.
• Automatic reclosure (AR) function (79)
• Synchronism check (25) • The self-adaptive floating threshold only reflects the
deviation of power frequency component, thus is immune to
• Frequency tracking
system imbalance and system disturbance.
• VT circuit supervision
• 24 samples per cycle, all task including data measurement,
• CT circuit supervision
protection calculation, logic discrimination, event recording
• Self diagnostic and protection logic calculation can be completed within one
• DC power supply supervision sampling period.
• Event recorder, including 256 binary input change reports, • Flexible automatic reclosure mode supporting multiple
256 self-supervision reports and 256 control reports initiation mode and check mode.
• Disturbance recorder, including 256 fault reports and 6 fault
• Overcurrent protection is provided in the relay for energizing
waveforms
a faulty bus or energizing a faulty line.
• GPS clock synchronization – PPS (pulse per second), PPM
(pulse per minute) and IRIG-B signal • The connector type can be selected as plug in/out terminal
connector or crimp terminal connector. The unique plug in/
• 2 RS-485 communication rear ports conform to IEC 60870-
out terminal connectors from the relay rear panel to the
5-103 protocol
terminal blocks on the rack or cabinet makes the on-site
• 1 RS-485 communication rear ports for clock synchronization commissioning and replacement much easier than the
• 2 or 4 optional Ethernet ports, IEC 61850, or IEC 60870-5- traditional screw terminals when you do the commissioning.
103 over TCP/IP

Read more on the web


www.nrelect.com read more on www.nrelect.com 169
Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001

Read more on the web


170 read more on www.nrelect.com www.nrelect.com
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 171
Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


172 read more on www.nrelect.com www.nrelect.com
RCS-923
Breaker Failure Protection

The RCS-923 is designed to provide breaker failure initiation


and auxiliary protection for circuit breakers. It also can be
used as the overcurrent protection of bus coupler or bus
section. The RCS-923 integrates breaker failure protection,
pole discrepancy protection, two stages phase overcurrent
protection, two stages zero-sequence overcurrent protection
and SOTF protection.

• 4 optional Ethernet ports, IEC 61850, or IEC 60870-5-103


over TCP/IP
• 1 RS-232 communication faceplate port for testing and
setting
• 1 RS-232 communication rear ports or RS-485 for printer

Features
• Overcurrent protection is provided in the relay for energizing
a faulty bus or energizing a faulty line.

• The self-adaptive floating threshold only reflects the


deviation of power frequency component, thus is immune to
system imbalance and system disturbance.
Functions
• The data acquisition system is completely independent
• Breaker failure initiation. (50BF) of electronic circuit. The DC power supply of output relay
• Two-stage phase overcurrent protection. (50P/51P) is switched on only if the general fault detector element
operates so as to avoid maloperation resulting from damage
• Phase directional overcurrent protection. (67P)
of any apparatus.
• Two stages zero-sequence overcurrent protection (50/51N)
• The connector type can be selected as plug in/out terminal
• Zero sequence directional overcurrent protection. (67N)
connector or crimp terminal connector. The unique plug in/
• Overcurrent protection for faulty bus or faulty line energizing. out terminal connectors from the relay rear panel to the
(50/51E) terminal blocks on the rack or cabinet makes the on-site
• Pole discrepancy protection. commissioning and replacement much easier than the
• Switch onto fault. (SOTF) traditional screw terminals when you do the commissioning.

• Self diagnostic test. • On the premise of 24 samples per cycle, all data
• Current drift auto regulation. measurement, calculation and logic discrimination can
be completed within one sampling period. The event
• Event Recorder including 128 binary input change reports,
recording and protection logic calculation are completed
128 self-supervision reports and 128 operating reports.
simultaneously.
• Disturbance recorder including 128 fault reports, and 24
waveforms. • The relay provides GPS clock synchronization, including
message, second pulse, minute pulse and IRIG-B
• Self diagnostic.
synchronization.
• 2 RS-485 communication rear ports conform to IEC 60870-
5-103 protocol • The relay is compatible with multiple protocols- IEC61850
and IEC 60870-5-103. It provides networking interface such
• 1 RS-485 communication rear ports for clock synchronization
as RS485, RS232 and Ethernet port.

Read more on the web


www.nrelect.com read more on www.nrelect.com 173
Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001

Read more on the web


174 read more on www.nrelect.com www.nrelect.com
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 175
Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

176 read more on www.nrelect.com


PCS-9830
Point-on-Wave Controller of CB

The PCS-9830 point-on-wave controller is a three-phase


control device for circuit breakers (CBs) to open or close at

Functions the specified phase angle on voltage waveform to minimize


the impulse caused by switching. The controlled switching
technology significantly eliminates harmful electrical
• Phase segregated closing function
transients upon planned switching, and thereby extending
• Phase segregated tripping function CB's service life and improving the stability of entire power
system.
• Self-adaptive compensation function

- Self-adaptive compensation function based on current


feedback
• Complete self-adaptive compensation function is provided.
- Self-adaptive compensation function based on position
feedback • Complete real-time status compensation function is provided.

• Realtime compensation functions • Opto-isolated binary inputs are provided.

- Realtime compensation function based on control circuit • Measurement of current and voltage, as well as monitoring of
voltage operation status are realized.

- Realtime compensation function based on mechanism • 32 operation records, 64 self-check records, and 64 binary
ambient temperature quantity/status change records are provided.

- Compensation function based on resting time • RS232 debugging serial port is provided. Software (PC end)
can be used for communication with the device, facilitating
• Current zero-drift automatic calibration function setup of settings, display of sampling, display of message,
and fault recording.

• Software and hardware can be selected flexibly according to


Features applications.

• 32-bit microprocessor is adopted to have faster calculation • Friendly HMI allows easy operation and commissioning.
and more reliable performance.
• Elaborate anti-interference assembly design with fully
• Complete phase selection closing/tripping function is enclosed chassis provide strong resistance to vibration and
provided and can be freely enabled or disabled. EM interference.

Technical data-
Item Description
Pole-segregated switching Open, Close
Auxiliary Power Supply 80% ~ 120% of rated voltage
Rated Voltage:
30Vdc/110Vdc/220Vdc;
110Vac ~ 220Vac
Rated Frequency (50 Hz or 60Hz) ± 5%
Power Consumption Steady state: <10W
Transient: <15W
Burden < 0.5 VA/Phase @ 1A
<1.0 VA/Phase @ 5A
Open/Close Circuit Current Adaptive
AC current Rated: 1 A or 5 A
Thermal withstand: 3In, Continuously
30In, 10 sec
100In, 1 sec
250In, half cycle

read more on www.nrelect.com 177


Temperature Transducer Selective:
4~20mA
0~10Vdc
0~250Vdc
Pressure Transducer Selective:
4~20mA
0~10Vdc
0~250Vdc
Adaptive Channels 6
Temperature Compensation Step & range is configurable.
Adaptive 6-point & 8-point curves
Adaptive mode Yes
Compensation mode Pressure compensation
Temperature compensation
Operating voltage compensation
Operating frequency compensation
1/3 Pole 1-pole or 3-pole, selective
Binary Output Relay paralleled with IGBT
Binary Input Dry contact
Event & wave record Yes

178 read more on www.nrelect.com


Generator and Generator-Transformer Unit Protection
Generator and Generator-Transformer Unit Protection Applications
How our products provide reliable, fast and accurate protection through our patented techniques are described in this section. Technical
data of different devices are provided in each relaying description.

Function Index

RCS-985RS

RCS-985SS
RCS-985TS
RCS-985G
RCS-985B

RCS-985C
RCS-985A

RCS-985T
PCS-985
Functional
Function
Code

Main protection for generator-transformer unit


Unrestraint current differential protection 87U √ √ √ √
Percentage restraint current differential protection 87P √ √ √ √
Main protection for generator
Unrestraint current differential protection 87UG √ √ √ √ √ √
Percentage restraint current differential protection 87PG √ √ √ √ √ √
DPFC current differential protection 87DG √ √ √ √ √
Split phase transverse differential protection 87SG √ √
Inter-turn fault protection
Sensitive transverse differential protection 87 √ √ √ √ √ √
Zero sequence overvoltage protection 59G √ √ √ √ √ √
Directional DPFC power protection 32D √ √ √ √ √ √
Back-up protection for generator
Phase-to-phase impedance protection 21P √ √ √ √ √
Voltage supervised overcurrent protection 50P/51P √ √ √ √ √ √
Stator ground fault protection 64S √ √ √ √ √ √
Basic frequency zero sequence voltage protection 59G √ √ √ √ √ √
Third harmonic neutral voltage protection 27TN √ √ √ √ √ √
Third harmonic voltage differential protection 87TH √ √ √ √ √
Phase-to-ground impedance protection (external 20Hz source) 21G √
Zero sequence overvoltage protection (external 20Hz source) 59G √
Axis current protection
Axis fundamental frequency current protection 51FF √ √
Axis third harmonic current protection 51TH √ √
Miscellaneous protection for generator
Rotor ground protection (one point and two point) 64R √ √ √ √ √ √
Stator overload protection 49S √ √ √ √ √ √
Rotor overload protection (negative sequence) 49R √ √ √ √ √ √
Loss of excitation protection 40 √ √ √ √ √ √
Out-of-step protection 78 √ √ √ √ √
Under/over voltage protection 27/59 √ √ √ √ √ √
Over excitation protection 24 √ √ √ √ √
Reverse power protection 32 √ √ √ √ √ √
Low forward power protection 32 √ √ √ √ √
Under/over frequency protection 81 √ √ √ √ √ √
Inadvertent energizing protection 50/27 √ √ √ √
Start/stop generator protection SS √ √ √ √ √
Voltage balance protection 60 √ √ √ √ √
Phase sequence protection 47 √ √ √ √ √
Low frequency overcurrent protection 50LF √ √ √ √ √
Main protection for main transformer
Unrestraint current differential protection 87UT √ √ √ √ √ √
Percentage restraint current differential protection 87PT √ √ √ √ √ √
DPFC current differential protection 87DT √ √ √ √
Back-up protection for main transformer HV side
Restricted earth fault protection REF √
Voltage supervised phase directional overcurrent protection 67P √ √
Voltage supervised phase overcurrent protection 50P/51P v √ √ √ √ √

read more on www.nrelect.com 179


Zero sequence directional overcurrent protection 67G √ √
Zero sequence overcurrent protection 50N/51N √ √ √ √ √ √
Phase-to-phase impedance protection 21P √ √ √ √
Ground overcurrent protection 50G/51G √ √ √ √ √ √
Gound overvoltage protection 59G √ √ √ √ √ √
Back-up protection for main transformer MV side
Restricted earth fault protection REF √ √
Voltage supervised phase directional overcurrent protection 67P √
Voltage supervised phase overcurrent protection 50P/51P √ √
Zero sequence directional overcurrent protection 67G √
Zero sequence overcurrent protection 50N/51N √ √
Phase-to-phase impedance protection 21P √
Ground overcurrent protection 50G/51G √ √
Ground overvoltage protection 59G √ √
Back-up protection for main transformer LV side or LV side branch
Voltage supervised phase overcurrent protection 50P/51P √ √
Zero sequence overcurrent protection 50N/51N √ √
Zero sequence overvoltage protection 59G v √ √ √ √ √
Miscellaneous protection for main transformer
Over excitation protection 24 √ √ √ √ √
Blocking on-load tap changer (OLTC) during overload √ √ √ √ √ √
Overload protection 49 √ √ √ √ √ √
Activating cooling equipment 49 √ √ √ √ √ √
Pole discrepancy function √ √ √ √ √ √
Main protection for auxiliary transformer
Unrestraint current differential protection 87UT √ √ √ √
Percentage restraint current differential protection 87PT √ √ √ √
Back-up protection for auxiliary transformer HV side
Voltage supervised phase overcurrent protection 50P/51P √ √ √ √
Back-up protection for auxiliary transformer LV side branch A
Voltage supervised phase overcurrent protection 50P/51P √ √ √ √
Zero sequence overcurrent protection 50N/51N √ √ √
Zero sequence overvoltage protection 59G √
Current differential protection for branch cable 87C √
Back-up protection for auxiliary transformer LV side branch B
Voltage supervised phase overcurrent protection 50P/51P √ √ √ √
Zero sequence overcurrent protection 50N/51N √ √ √
Zero sequence overvoltage protection 59G √
Current differential protection for branch cable 87C √
Miscellaneous protection for auxiliary transformer
Overload protection 49 √ √ √ √
Activating cooling equipment 49 √ √ √ √
Excitation transformer or exciter protection
Current differential protection for excitation transformer 87E √ √ √ √ √
Current differential protection for exciter 87E √ √ √ √ √
Phase overcurrent protection 50P/51P √ √ √ √ √ √
Thermal overload protection 49 √ √ √ √ √
Miscellaneous
Mechanical protection MR √ √ √ √ √ √
CT failure detection logic √ √ √ √ √ √ √ √
VT failure detection logic √ √ √ √ √ √ √
Tripping/Closing circuit supervision √ √ √ √ √ √ √ √ √
GPS clock synchronization √ √ √ √ √ √ √ √ √
Fault Recorder √ √ √ √ √ √ √ √ √
IEC61850 MMS & GOOSE for station bus √
IEC61850-9-2 SV & IEC61850-8-1 GOOSE for process bus √
IEC60870-5-103 protocol √ √ √ √ √ √ √ √ √
MODBUS protocol √ √ √ √ √ √ √ √ √
DNP 3.0 LAN √

180 read more on www.nrelect.com


PCS-985
Generator-Transformer Unit Protection

The PCS-985 provides the complete main and backup


protection of generator-transformer units which usually
comprises generator, main transformer, auxiliary transformer
and exciter or excitation transformer.It supports connections
to conventional CTs/VTs and Electronic CTs/VTs, and is
widely used in large capacity turbo-dynamo, gas-turbine
generator and nuclear power generator with different
connection modes.
Functions
For a vital generator-transformer unit, two sets of PCS-985
Generator protection can be used to achieve duplicated protection configuration.
• Differential protection. (87G) Two PCS-985 use different CT groups, and main and backup
• DPFC differential protection. (87G) protection in one PCS-985 share one CT group.

• High sensitive transverse differential protection. (87G)


• Longitudinal zero-sequence overvoltage protection for inter-
turn fault. (59N/60)
• Third harmonic overvoltage differential protection for stator
• DPFC directional protection for inter-turn fault. (67) earth fault. (64S)
• Voltage controlled overcurrent protection. (50) • 100% stator earth-fault protection with voltage injection. (64R)
• Phase-to-phase impedance protection. (21G) • Rotor one-point earth-fault protection. (64R1)
• Extreme current blocking function at generator terminal. • Rotor two-point earth-fault protection. (64R2)
• Fundamental zero-sequence voltage protection for stator • Definite-time stator overload protection. (50S)
earth fault . (64S)
• Inverse-time stator overload protection. (51S)
• Third harmonic overvoltage ratio protection for stator earth
• Definite-time negative-sequence overload protection. (50Q)
fault. (64S)
• Inverse-time negative-sequence overload protection. (51Q)

Typical Applications

read more on www.nrelect.com 181


• Loss-of-excitation protection. (40) • Voltage controlled overcurrent protection of branch 1 at LV
• Out-of-step protection. (78) side. (50P)

• Overvoltage protection. (59) • Voltage controlled overcurrent protection of branch 2 at LV


side. (50P)
• Definite-time over-excitation protection. (24)
• Zero-sequence overcurrent protection of branch 1 at LV side.
• Inverse-time over-excitation protection. (24)
(50G)
• Reverse-power protection. (32R)
• Zero-sequence overcurrent protection of branch 2 at LV side.
• Low-power protection. (37G) (50G)
• Sequential tripping reverse-power protection. (32R) • Overload alarm. (49)
• Underfrequency protection. (81U) • Initiating cooling. (49)
• Overfrequency protection. (81O) • Blocking on-load tap change. (OLTC)
• Startup/shutdown protection of differential current. • VT circuit supervision. (VTS)
• Startup/shutdown protection of zeros-equence voltage. • CT circuit supervision. (CTS)
• Low-freuquency overcurrent protection. (50)
• Inadvertent energization protection. (50/27) Miscellaneous
• Breaker failure protection. (50BF) • Mechanical protection.
• Voltage balance function. (60) • Voltage and current drift auto adjustment.
• VT circuit supervision. (VTS) • Self diagnostic.
• CT circuit supervision. (CTS) • GPS clock synchronization.
• Fault Recorder.
Excitation Transformer/Excitor Protection
• Differential protection. (87ET)
• Overcurrent protection. (50) Features
• Definite-time overload protection. (50)
• Inverse-time overload protection. (51) • High-performance unified hardware and realtime calculations
This relay adopts high performance CPUs and DSPs,
Main Transformer Protection internal high-speed bus, and intelligent I/O. Both hardware
and software adopt modular design, which can be flexibly
• Generator-transformer unit differential protection. (87GTU)
configured.
• Differential protection. (87T)
• DPFC differential protection. (87T)
• Independent fault detector elements
• Restricted earth-fault protection. (64REF) The unique hardware design with two independent data
• Phase-to-phase impedance protection at HV side. (21P) acquisition paths can prevent the maloperation due to
• Voltage controlled overcurrent protection at HV side. (50) the hardware component failure. The tripping output is
continuously supervised by the independent fault detector
• Overload alarm. (49)
element executed in the separated CPU. It will significantly
• Initiating cooling. (49)
enhance the reliability.
• Directional zero-sequence overcurrent protection at HV side.
(67G)
• Variable slope percentage differential protection
• Inverse-time zero-sequence overcurrent protection at HV Variable slope percentage characteristic is adopted for
side. (51G) current differential protection. If the pickup slope and
• Gap zero-sequence voltage protection at HV side. maximum slope are reasonably set, high sensitivity can be
• Gap zero-sequence current protection at HV side. gained during internal fault, while transient unbalance current
• Zero-sequence voltage alarm at LV side. can be avoided during external fault.
• Definite-time over-excitation protection. (24)
• DPFC percentage differential protection
• Inverse-time over-excitation protection. (24)
DPFC percentage differential protection reflects only
• Pole discrepancy protection at HV side. (62PD) deviation components of differential current and restraint
• Breaker flashover protection. current, it is not effected by load current. It can detect
• VT circuit supervision. (VTS) slight fault within transformer and generator. Besides, it is
• CT circuit supervision. (CTS) insensitive to CT saturation since its restraint coefficient is
set comparatively high.

Auxiliary Transformer
• Detect CT Saturation by asynchronous method
• Differential protection. (87T)
For external fault, waveform discrimination of phase current
• Voltage controlled overcurrent protection at HV side. (50P)
and differential current is adopted. Maloperation will not occur

Read more on the web


182 read more on www.nrelect.com www.nrelect.com
if the CT correct transfer time from primary to secondary side rotor winding voltage, rotor ground resistance and earthing
is not less than 5ms. For internal fault, the device will operate position on real time and display these information on LCD.
quickly.
• Rotor earth-fault with external voltage injection principle
• High-sensitive transverse differential protection The protection method is adaptive to various lead-out mode
By adopting frequency tracking, digital filter and Fourier of rotor windings, and both single-end injection and double-
transformation, the filtration ratio of third harmonic component ends injection can be selected. The fault location can be
can reach more than 100. All these countermeasure measured if double-ends injection is selected.
guarantees the reliability of protection in all occasions.
• Loss-of-excitation protection
• Percentage restraint interturn protection Loss-of-excitation protection optionally combines stator
The device adopts new criteria of generator current impedance criteria, reactive power criteria, rotor voltage
percentage restraint technique to ensure the accurate criteria and busbar voltage criteriato meet various demands
operation during inter-turn fault occurs in stator winding of different generator units.
and prevent maloperation during external asymmetric fault
occurs. • Out-of-step protection
Out-of-step protection adopts three-impedance element
• Stator earth-fault protection (gains from positive-sequence current and positive sequence
Through the realtime adjustment of coefficient of amplitude voltage of generator) to distinguish out-of-step from steady
value and phase, the PCS-985 makes differential voltage oscillation. In addition, the protection can accurately locates
between generator terminal and neutral point 0 in a normal the position of oscillation center and record the oscillation slid
operation condition. When stator earth fault occurs, the numbers of external and internal oscillation respectively in
criteria tend to operate reliably and sensitively. real-time.

• Stator earth-fault protection with external voltage injection • Powerful communication function
principle 2 independent Ethernet interfaces and 2 independent RS-
The protection adopts digital technology to calculate the 485 communication interfaces are provided. Power industry
earth fault resistance accurately. The protection is adaptive communication standard IEC60870-5-103, Modbus protocol
for various operation conditions, such as stillness, no-load, and new generation substation communication standard
shutdown, startup and connected to power grid. IEC61850 are supported.

• Rotor earth-fault protection with ping-pong principle • Complete event recording function
DC current is input by high-performance isolated amplifier. 64 faults and operation sequence, 64 fault waveforms,
Via switching two different electronic switches, the PCS- results of 256 self-supervision reports, and 1024 binary
985 solves four different ground-loop equations to compute signal change reports can be recorded.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
Quiescent condition <50W
Burden
Operating condition <70W

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 100In
for half a cycle 250In
Burden <0.15VA/phase < 0.25VA/phase

Read more on the web


www.nrelect.com read more on www.nrelect.com 183
Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V
linear to 1~170V
continuously 200V
Thermal withstand capability 10s 260V
1s 300V
Burden < 0.20VA/phase @Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 48V 110V 125V 220V 250V
Rated current 1.2mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 55%~70% of rated voltage
Dropout voltage <55% of rated voltage
Maximum permissive voltage 120% of rated voltage
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current
[email protected] [email protected]
0.4A resistance 0.2A resistance
Breaking capacity (L/R=40ms)
0.2A inductive(L/R=40ms) 0.05A inductive (L/R=40ms)
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×354.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×354.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

Read more on the web


184 read more on www.nrelect.com www.nrelect.com
- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 185
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


186 read more on www.nrelect.com www.nrelect.com
RCS-985A/B/C
Generator-Transformer Unit Protection

The RCS-985A/B/C generator-transformer unit protection


provides comprehensive protection, control and monitoring
of small to large generators, generator-transformer units,
main transformers, auxiliary transformers, excitation
transformers and exciters. Hardware inputs and outputs
have been designed in a modular format allowing easy
upgrade from simple to complicated applications. For
Functions large generator-transformer units, two devices installed in
separated panels are required for duplicated protection using
different independent CT groups. The RCS-985A/B/C is fully
Protection for Generator
compatible with IEC 61850 communication with an additional
• Differential protection. (87G)
communication unit.
• Unrestrained instantaneous differential protection. (87UG)
• DPFC differential protection. (87G)
• Spilt-phase transverse differential protection. (87G)
• High sensitive transverse differential protection. (87G)
• DPFC directional protection for turn-to-turn fault fault. (67)
• Longitudinal zero-sequence overvoltage protection for inter-
• Voltage controlled overcurrent protection. (51V)
turnReverse power protection. (32G
• Two stages phase-to-phase impedance protection. (21G)
• Sequent-tripping reverse power protection. (32G)
• Terminal high-current blocking function.
• Four stages underfrequency protection. (81G)
• Fundamental zero sequence overvoltage protection for stator
• Two stages overfrequency protection. (81O)
earth fault. (64G1)
• Startup/shutdown protection of generator.
• T h i r d h a r m o n i c p r o t e c t i o n f o r s t a t o r e a r t h f a u l t .
• Accidental energization protection. (50/27) (27/59TN,64G2)
• Pole disagreement function. (92PD) • Two stages of one-point-earth fault protection of rotor. (64R)
• Voltage balance function. (60) • Rotor two-point earth fault protection (Optional). (64R)
• Voltage transformer supervision. (47,60G) • Definite and inverse time stator thermal overload protection.
• Current transformer supervision 50/74 fault. (59N/60) (49S)

Read more on the web


www.nrelect.com read more on www.nrelect.com 187
• Definite and inverse time negative sequence overload • Cooling initiation function. (49)
protection of rotor. (46/50, 46/51, 49R) • Zero-sequence voltage alarm of branches at LV side. (59G)
• Loss-of-excitation protection. (40) • VT circuit failure supervision
• Out-of-step protection. (68/78) • CT circuit failure supervision
• Two stages phase-to-phase overvoltage protection. (59G) • CT saturation detection
• Phase-to-phase undervoltage protection. (27G)
• Two stages definite time over-excitation protection. (24) Miscellaneous
• Inverse time over-excitation protection. (24) • Mechanical protection.
• Voltage and current drift auto adjustment.
Protection for Excitation • Self diagnostic.
• Current differential protection for excitation transformer. (87T) • GPS clock synchronization.
• Current differential protection of AC exciter. (87G) • Fault Recorder.
• Overcurrent protection. (50P/51P) • 32 latest fault reports, 8 latest fault waveforms, 32 latest
• Definite and inverse time thermal overload protection for abnormality reports and 32 latest binary status input change
exciting windings. (87G) reports
• Current transformer supervision of excitation set. (50/74) • four RS-485 ports(two can be configured as fiber port)
compatible with IEC 60870-5-103/MODBUS
Protection for stepdown transformer • one RS-485 or RS-232 port for communication with printer
• Differential protection. (87T)
• Composite-voltage-blocking overcurrent protection. (51V)
• Under voltage blocking overcurrent protection of branch 1.
Features
(51/27G) • The hardware of each CPU system comprises one
• Under voltage blocking overcurrent protection of branch 2. microprocessor and two digital signal processors (DSP).
(51/27G) Two CPU systems can operate in parallel acompanied by a
• Zero sequence overcurrent protection of branch 1. (50P, 51P) fast A/D converter. The 32-bit microprocessor performs logic
calculation and the DSPs perform the protection calculation.
• Zero sequence overcurrent protection of branch 2. (50P, 51P)
High performance hardware ensures real time calculation of
• Zero-sequence voltage alarm of LV side branch 1. all protection relays within a sampling interval.
• Zero-sequence voltage alarm of LV side branch 2.
• Main and backup protection are integrated in one package.
• Overload alarm. (49) Protection information such as sampled data and binary
• Cooling pickup. (49) inputs are shared by all protective elements.
• Overcurrent output function. • The percentage differential protection adopts variable slope
• Voltage transformer supervision. (47,60G) restraint characteristic and the actual unbalanced differential
• Current transformer supervision. (50/74) current effect can be simulated. In order to prevent
maloperation of differential protection due to CT saturation,
waveform distortion detection of phase current at each side
Protection for Main Transformer are provided to discriminate CT saturation.
• Generator-transformer unit current differential protection
.87GT • The DPFC percentage differential protection is immune
to load current that it reflects the deviation components of
• Transformer current differential protection. (87T)
differential current and restraint current only. Besides, it is
• Unrestrained differential protection. (50/87UT) insensitive to CT saturation since its restraint coefficient is
• DPFC current differential protection. (87T) set comparatively higher than that of conventional differential
• Impedance protection at HV side. (21T) protection.

• Voltage controlled overcurrent protection at HV side. (50P/ • Two discrimination principles for inrush current are provided:
51P) harmonics restraint and waveform distortion restraint.
• Voltage controlled zero-sequence overcurrent protection at • Based on the operation sequence of DPFC restraint current
HV side. (50N/ 51N) element and DPFC differential current element of differential
• Voltage controlled directional zero-sequence overcurrent protection, external fault with CT saturation or internal fault
protection at HV side. (67N) can be distinguished correctly.
• Zero-sequence overvoltage protection at HV side (Gap • The transverse differential protection adopts percentage
overvoltage). (59N) phase current restraint and floating threshold to achieve high
• Zero-sequence overcurrent protection at HV side (Gap sensitivity in internal fault and high security in external fault.
overcurrent). (50N/51N)
• The loss-of-excitation protection adopts optimizing protection
• Overexcitation protection. (24) scheme in which stator impedance criteria, reactive power
• Thermal overload protection. (49) criteria, rotor voltage criteria, busbar voltage criteria and

Read more on the web


188 read more on www.nrelect.com www.nrelect.com
criteria of stator active power decrement, can be optionally • Two groups of VT inputs are equipped at generator terminals.
combined to meet various demands of operation of the unit If one group fails, the equipment will issue an alarm and
for different generator. switch over to the healthy one automatically.

• Out-of-step protection adopts three-impedance element • Percentage differential principle is used to enhance the ability
to distinguish out-of-step from steady oscillation. The to detect CT circuit failure and to avoid maloperations.
protection can accurately locate the position of oscillation
• Various GPS clock synchronizations: second/minute pulse
center and record theoscillation slide numbers of external
via binary input or RS-485, message via communication
and internal oscillation respectively in realtime.
ports and IRIG-B synchronization.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 40 W
Burden
Operating condition < 70 W
Backup battery type 1/2AA, 3.6V, 60mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
40In (Transformer related) 40In (Transformer related)
Linear to (non-offset AC current) 20In (Generator related) 20In (Generator related)
2In (for metering CT) 2In (for metering CT)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Continuous carry 8A 5A

Read more on the web


www.nrelect.com read more on www.nrelect.com 189
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×532.6mm×285 mm
Trepanning dimensions (W×H) 450mm×534mm M6 screw
Mounting Flush mounted
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
RS-485 (EIA) Connector type ST
Baud rate 4800 ~ 38400bps
Transmission standard 100Base-FX,
Transmission distance <1500m
Optical (Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Rear interface for local HMI with personal computer via RCSPC software
Port number 1
Local human-machine communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800 ~ 9600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


190 read more on www.nrelect.com www.nrelect.com
Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 191
RCS-985G
Generator Protection

The RCS-985G is a generator protection intended for the


application to sophisticated generators, including turbo-
generators, hydro-generators, gas turbine generators and
pumped-storage generators. It supports wall surface mounted
and flush mounted in a control panel. The RCS-985G is fully
Functions compatible with IEC 61850 communication with an additional
communication unit.

Protection for Generator


• Current differential protection. (87G)
• Unrestrained instantaneous differential protection. (87UG)
• DPFC current differential protection. (87G) • Phase-to-phase undervoltage protection. (27G)
• High sensitive transverse differential protection. (87G) • Two stages definite time over-excitation protection. (24)
• Longitudinal zero sequence overvoltage protection for turn- • Inverse time over-excitation protection. (24)
to-turn fault. (59N/60)
• Reverse power protection. (32G)
• DPFC directional protection for turn-to-turn fault. (67)
• Reverse power protection during generator shutting down.
• Two stages phase-to-phase distance protection. (21G) (32G)
• Voltage controlled overcurrent protection. (51V) • Three stage underfrequency protection. (81G)
• Current blocking element at generator’s terminal. • Two-stage overfrequency protection. (81O)
• Fundamental zero sequence overvoltage protection for stator • Startup/shutdown protection of generator.
earth fault. (64G1)
• Accidental energization protection. (50/27)
• Third harmonic protection for stator earth fault. (27/59TN,
• Voltage balance function. (60)
64G2)
• Under-frequency overcurrent protection.
• Two stages of one-point-earth fault protection of rotor. (64R)
• Voltage transformer supervision. (47/60G)
• Two-point earth fault protection of rotor. (64R)
• Current transformer supervision. (50/74)
• Definite and inverse time stator thermal overload protection.
(49S) • Mechanical protection.
• Definite and inverse time negative sequence overload
protection of rotor. (46/50, 46/51, 49R) Excitation System
• Loss-of-excitation protection. (40) • Current differential protection for exciting-transformer. (87T)
• Out-of-step protection. (68/78) • Current differential protection of AC exciter. (87G)
• Two stages phase-to-phase overvoltage protection. (59G) • Overcurrent protection. (50P/51P)
• Definite and inverse time thermal overload protection for
exciting windings. (87G)
• Current transformer supervision of excitation set. (50/74)

Monitoring and Metering


• Automatic self-supervision
• Fault recording
• Event recording
• Present recording
• Front communication port (RS232)
• Rear communication ports to host
• Rear communication port to printer
• Time synchronization
• Voltage and current drift auto-adjustment.

Read more on the web


192 read more on www.nrelect.com www.nrelect.com
Features
• The CPU hardware comprises of one microprocessor and 1500 internal data of equipment can be supervised by the
two digital signal processors(DSP). The two CPU systems dedicated auxiliary software which enables users to be aware
can operate in parallel with a fast A/D converter. The logic of the operational status of RCS-985G.
calculations are processed by microprocessor and the
• The stator ground fault protection adopts the proportion of
protection calculations are carried out by DSP, ensuring
third harmonic voltages of generator output and neutral point.
that the real time calculation of all protection relays can be
This criterion ensures that no unwanted alarm can be sent
completed in a sampling interval.
during startup/shutdown process of the generator.
• The fault detectors in CPU processor are used to supervise
• The rotor earth fault protection adopts ping-pong principle.
tripping outputs. The relay drives the tripping output only
Its DC input uses high performance isolated amplifier. Real-
when the fault detectors in CPU module and MON module
time display of voltage and insulation resistance of the rotor
operate simultaneously so as to avoid maloperation caused
as well as the location of its ground point can be realized.
by hardware component failures.
• Loss of excitation protection adopts open criterion. Many
• The RCS-985G can be used as main and backup protection
criterions such as stator impedance, reactive power, rotor
of generators. Protection information such as sampled data
voltage, busbar voltage and active power reduction of stator
and binary inputs are shared between all protective elements.
can be combined flexibly. Requirements of operation of
• The RCS-985G can be applied to various circuit breakers different type generator-transformer unit can be met then.
with its elaborately designed tripping matrix.
• Triple impedance elements are adopted by out-of-step
• The percentage differential protection adopts variable protection, power swing and out-of-step can be discriminated
slope restraint characteristics, and the actual unbalanced correctly. It can also locate the swing center and can make
differential current effect can be simulated. The phase current real-time record of number of pole slipping of internal swing
waveform is identified to prevent maloperation due to CT and external swing respectively.
saturation.
• VT circuit failure supervision is integrated. Two groups of VT
• The DPFC percentage differential protection is used to reflect inputs are equipped for generator end. If one group fails the
deviation components of differential current. It can detect equipment will send alarm and switch to the healthy group
small fault in transformers and generators, and is immune to automatically. It doesn’t need to block protective function
CT saturation due to the high restraint coefficient. relevant to voltage of generator.

• The CT current output will be corrected before calculation to • CT circuit failure alarm and blocking is integrated. This
eliminate the influence of different CT ratio function adopts percentage differential principle. Detection
ability of CT circuit failure can be enhanced significantly and
• Two discrimination principles for inrush current are provided:
unwanted operation can be avoided then.
harmonics restraint and waveform distortion restraint.
• The connector type can be selected as plug in/out terminal
• CT saturation detecting logic can prevent mal-operation in
connector or screw terminal connector. The unique plug
case of external fault and improve operational performance
in/out terminal connectors from the relay rear panel to
under condition of internal fault. For external faults, mal-
the terminal blocks on the rack or cabinet makes the on-
operation can be avoided if the transfer time from primary to
site commissioning and replacement much easier than the
secondary side of CT is no less than 5ms.
traditional screw terminals when you do the commissioning.
• The transverse differential protection adopts the percentage
• Various GPS clock synchronizations are provided: second/
phase current restraint and the floating threshold to
minute pulse via binary input or RS-485, message via
enhance ensitivity and reliability. The filtration ratio of third
communication ports and IRIG-B synchronization.
component can be increased to over 100 with the application
of frequency tracking technique, digital filter technique and • The relay is equipped with Ethernet ports with IEC 61850 (one
Fourier transformation technique. additional communication unit is required) and RS-485 ports
with IEC 60870-5-103.
• More than 500 sampled data including differential current
and phase angle can be displayed on LCD. More than

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms

Read more on the web


www.nrelect.com read more on www.nrelect.com 193
Quiescent condition < 40 W
Burden
Operating condition < 70 W
Backup battery type 1/2AA, 3.6V, 60mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
40In (Transformer related) 40In (Transformer related)
Linear to (non-offset AC current) 20In (Generator related) 20In (Generator related)
2In (for metering CT) 2In (for metering CT)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms (only DSP)
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×532.6mm×285 mm
Trepanning dimensions (W×H) 450mm×534mm M6 screw
Mounting Flush mounted
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Read more on the web


194 read more on www.nrelect.com www.nrelect.com
Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
RS-485 (EIA) Connector type ST
Baud rate 4800 ~ 38400bps
Transmission standard 100Base-FX,
Transmission distance <1500m
Optical (Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Rear interface for local HMI with personal computer via RCSPC software
Port number 1
Local human-machine communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800 ~ 9600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

Read more on the web


www.nrelect.com read more on www.nrelect.com 195
- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


196 read more on www.nrelect.com www.nrelect.com
RCS-985RS/SS
Generator Protection

The RCS-985RS/SS are complete protection solution


designed for the appliations to medium to steam turbine
generator, water turbine generator and gas turbine
generator with small to medium capacity. It adopts dual CPU
configuration for fault detector element and protection logic to
enhance operation accuracy. The RCS-985RS/SS are fully
compatible with IEC 61850 communication with an additional
communication unit.

• Transverse differential protection. (87)


• Voltage controlled overcurrent protection. (50/51)
• Stator earth-fault protection. (64S)
- Fundamental zero-sequence voltage protection
- Zero-sequence overcurrent protection
- Third harmonic voltage ratio protection

• Loss-of-excitation protection. (40)


• Reverse power protection. (32)
• Sequential tripping reverse power protection
• Voltage protection. (27/59)
• Frequency protection. (81)
• VT circuit supervision

Functions • CT circuit supervision


• Selective trip for large faulty current
Protection and control • Mechanical protection
• Variable slope percentage differential protection. (87)
• Unrestrained differential protection. (87) Monitoring and metering
• One-point earth-fault protection of rotor. (64R) • Self diagnostic
• Two-points earth-fault protection of rotor. (64R) • DC power monitoring and alarming
• Definite-time stator overload protection. (49S) • Event Recorder including 256 statuses change of binary
• Inverse-time stator overload protection. (49S) input reports, 64 self-supervision reports and 64 operating
reports.
• Definite-time negative-sequence overcurrent protection.
(50/51Q) • Disturbance recorder including 64 fault reports, and 8
waveforms. The maximal record time is up to 15s for single
• Inverse-time negative-sequence overcurrent protection.
fault waveform. (The file format of disturbance recorder is
(50/51Q)
compatible with international COMTRADE file.)
• Definite-time excitation winding overcurrent protection.
• GPS clock synchronization: PPS (pulse per second) or
(50/51)
IRIG-B signal via RS-485
• Inverse-time excitation winding overcurrent protection.
(50/51)
Communication
• Overcurrent protection of rotor body. (50/51)
• 2 RS-485 communication rear ports conform to IEC 60870-5-
• Selective trip for large faulty current
103 protocol or Modbus protocol
• Interturn protection
• 3 optional Ethernet ports conform to IEC 60870-5-103
- Longitudinal zero-sequence voltage protection protocol over TCP/IP
- DPFC directional protection

Read more on the web


www.nrelect.com read more on www.nrelect.com 197
Features
• T h e h a r d w a r e o f C P U s y s t e m c o m p r i s e s o f o n e • The RCS-985RS/SS provide complete independent
microprocessor and one DSP. The two processors can protection functions which can be enabled or disabled freely.
operate in parallel with a fast 14bits A/D converter. Logic
• The independent fault detectors in the CPU processor can
calculation and protection calculation are executed by the 32-
provide realtime supervision of tripping outputs. The relay will
bit microprocessor and the DSP separately.
drive the tripping output only when the fault detectors in the
• The protection module is completely separated from other CPU module and in the MON module operate simultaneously.
modules and is independent of communication network.
• The connector type can be selected as plug in/out terminal
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a connector or screw terminal connector. The unique plug
measurement, calculation and logic discrimination can in/out terminal connectors from the relay rear panel to
be completed within one sampling period. The event the terminal blocks on the rack or cabinet makes the on-
recording and protection logic calculation are completed site commissioning and replacement much easier than the
simultaneously. traditional screw terminals when you do the commissioning.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type 1/2AA, 3.6V, 60mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 40In (Transformer related) 40In (Transformer related)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Read more on the web


198 read more on www.nrelect.com www.nrelect.com
Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 213.2mm×266mm×232mm
Trepanning dimensions (W×H) 215mm×267mm, M5 screw
Mounting Flush mounted
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
RS-485 (EIA) Connector type ST
Baud rate 4800 ~ 38400bps
Transmission standard 100Base-FX,
Transmission distance <1500m
Optical (Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Rear interface for local HMI with personal computer via RCSPC software
Port number 1
Local human-machine communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800 ~ 9600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 199
Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


200 read more on www.nrelect.com www.nrelect.com
RCS-985T
Transformer Protection

The RCS-985T is a high-performance transformer protection


intended for the applications to startup/standby transformers
and auxiliary transformers in power plants. This full-integrated
transformer protection integrates protection, control and
monitoring functions to provide users with a comprehensive,
reliable and cost-effective solution. The RCS-985T is fully
compatible with IEC 61850 communication with an additional
communication unit.

Functions
Protection and control
• Variable slope percentage differential protection (7 sides • Voltage controlled overcurrent protection of branches at LV
maximum). (87T) side. (50P/51P)
• Unrestrained differential protection. (50/87UT) • Pole disagreement protection. (62PD)
• Restricted earth fault protection(zero-sequence differential • Over excitation protection. (24)
current protection) at HV side. (64REF/87G) • Thermal overload protection. (49)
• Restricted earth fault protection(zero-sequence differential • Cooling initiation function. (49)
current protection) at LV side A. (64REF/87G)
• On-load tap change (OLTC) blocking function during
• Restricted earth fault protection(zero-sequence differential overload. (49)
current protection) at LV side B. (64REF/87G)
• Zero-sequence voltage alarm of branches at LV side. (59G)
• Voltage controlled overcurrent protection at HV side. (50P/
• VT circuit failure supervision.
51P)
• CT circuit failure supervision.
• Voltage controlled directional zero-sequence overcurrent
protection at HV side. (50N/51N/67N) • CT saturation detection.

• Gap zero-sequence overvoltage protection at HV side. (59N)


Monitoring and metering
• Gap zero-sequence overcurrent protection at HV side.
(50N/51N) • Self diagnostic
• DC power monitoring and alarming
• Event Recorder including 256 statuses change of binary
input reports, 64 self-supervision reports and 64 operating
reports.
• Disturbance recorder including 64 fault reports, and 8
waveforms. The maximal record time is up to 15s for single
fault waveform. (The file format of disturbance recorder is
compatible with international COMTRADE file.)
• GPS clock synchronization: PPS (pulse per second)

Communication
• 2 RS-485 communication rear ports conform to IEC 60870-5-
103 protocol or Modbus protocol.
• 3 optional Ethernet ports conform to IEC 60870-5-103
protocol over TCP/IP.

Read more on the web


www.nrelect.com read more on www.nrelect.com 201
Features • The percentage differential protection adopts variable
slope restraint characteristics, and the actual unbalanced
• The hardware of CPU system comprises one 32 bit differential current effect can be simulated. The phase current
microprocessor and one DSP. The two processors can waveform is identified to prevent maloperation due to CT
operate in parallel with a fast 14bits A/D converter. Logic saturation.
calculation and protection calculation are executed by the 32- • The CT current output will be corrected before calculation to
bit microprocessor and the DSP separately. eliminate the influence of different CT ratio
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a • Two discrimination principles for inrush current are provided:
measurement, calculation and logic discrimination can harmonics restraint and waveform distortion restraint.
be completed within one sampling period. The event
recording and protection logic calculation are completed • CT saturation detecting logic can prevent mal-operation in
simultaneously. case of external fault and improve operational performance
under condition of internal fault. For external faults, mal-
• The fault detectors in CPU processor are used to supervise operation can be avoided if the transfer time from primary to
tripping outputs. The relay drives the tripping output only secondary side of CT is no less than 5ms.
when the fault detectors in CPU module and MON module
operate simultaneously so as to avoid maloperation caused • The independent fault detectors in the CPU processor can
by hardware component failures. provide realtime supervision of tripping outputs. The relay will
drive the tripping output only when the fault detectors in the
• The RCS-985T can be used as main and backup protection CPU module and in the MON module operate simultaneously.
for transformers in power plants. Protection information such
as sampled data and binary inputs are shared between all • Various GPS clock synchronizations are provided: second/
protective elements. minute pulse via binary input or RS-485, message via
communication ports and IRIG-B synchronization.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 40 W
Burden
Operating condition < 70 W
Backup battery type 1/2AA, 3.6V, 60mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
40In (Transformer related) 40In (Transformer related)
Linear to (non-offset AC current) 20In (Generator related) 20In (Generator related)
2In (for metering CT) 2In (for metering CT)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Read more on the web


202 read more on www.nrelect.com www.nrelect.com
Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Making Capacity 30A
Continuous carry 5A, 8A, 10A (select one) 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×353.6mm×285mm
Trepanning dimensions (W×H) 450mm×355mm, M6 screw
Mounting Flush mounted
Housing material Aluminum
Housing color Silver grey
Front side: IP40, up to IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
RS-485 (EIA)
Baud rate 4800 ~ 38400bps
Transmission standard 100Base-FX,
Transmission distance <1500m
Optical (Optional) Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
IEC60870-5-103:1997
Protocol
MODBUS
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 203
Rear interface for local HMI with personal computer via RCSPC software
Port number 1
Local human-machine communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800 ~ 9600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Type 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, PPM, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


204 read more on www.nrelect.com www.nrelect.com
RCS-985TS
Transformer Protection

The RCS-985TS provides transformer protection for two-


winding and three-winding main transformers, auxiliary
transformers and startup/standby transformers in power
plants with voltage level up to 220kV. It integrates protection,
control and monitoring functions in one package, providing
users with effective and reliable solutions. The RCS-
985TS offers differential protection for up to three CT
inputs. The RCS-985TS is fully compatible with IEC 61850
communication with an additional communication unit.

• CT circuit failure supervision


• CT saturation detection
• Inrush current detection

Monitoring and communication


• Self diagnostic
• DC power monitoring and alarming
• Event Recorder including 256 statuses change of binary
input reports, 64 self-supervision reports and 64 operating
reports.
• Disturbance recorder including 64 fault reports, and 8
waveforms. The maximal record time is up to 15s for single
fault waveform. (The file format of disturbance recorder is
compatible with international COMTRADE file.)
• GPS clock synchronization
Functions • Rear communication ports: Ethernet (Optional) with IEC
61850(additional communication unit) and RS-485 with IEC
Protection and control 60870-5-103 protocol, 1 RS-485 with clock synchronization,
• Variable slope percent differential protection. (87T) 1 RS-232 or RS-485 with printer.
• Unrestrained differential protection. (87UT)
• Restricted earth fault protection. (REF)
• Phase overcurrent protection. (50/51P)
Features
• Ground overcurrent protection. (50G/51G) • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Zero-sequence overcurrent protection. (50/51N) measurement, calculation and logic discrimination can
be completed within one sampling period. The event
• Gap zero-sequence overvoltage protection. (59G)
recording and protection logic calculation are completed
• Zero-sequence voltage alarm function. (59G) simultaneously.
• Overload alarm. (49) • The fault detectors in CPU processor are used to supervise
• Overload initiating cooling. (49) tripping outputs. The relay drives the tripping output only
• On-load tap change (OLTC) blocking function during when the fault detectors in CPU module and MON module
overload. (49) operate simultaneously so as to avoid maloperation caused
by hardware component failures.
• CB breaking capacity blocking.
• Voltage control element. (VCE) • The RCS-985TS can be used as main and backup protection
for transformers in power plants. Protection information such
• Current control element. (CCE)
as sampled data and binary inputs are shared between all
• VT circuit failure supervision protective elements.

Read more on the web


www.nrelect.com read more on www.nrelect.com 205
• The percentage differential protection adopts variable secondary side of CT is no less than 5ms.
slope restraint characteristics, and the actual unbalanced
• The independent fault detectors in the CPU processor can
differential current effect can be simulated. The phase current
provide realtime supervision of tripping outputs. The relay will
waveform is identified to prevent maloperation due to CT
drive the tripping output only when the fault detectors in the
saturation.
CPU module and in the MON module operate simultaneously.
• The CT current output will be corrected before calculation to
• The fault detector can record the operational events of
eliminate the influence of different CT ratio
analog components, differential current and time sequence
• The harmonics restraint method is used to discriminate protection elements. The latest 8 fault waveforms can be
inrush current. recorded for up to 15s each. The format of fault reports is
compatible with the international COMTRADE file.
• The CT saturation detecting logic can prevent mal-operation
in case of external fault and improve operation performance • Various GPS clock synchronizations are provided: second/
under the condition of internal fault. For external faults, mal- minute pulse via binary input or RS-485, message via
operation can be avoided if the transfer time from primary to communication ports and IRIG-B synchronization.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 40In (Transformer related) 40In (Transformer related)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Read more on the web


206 read more on www.nrelect.com www.nrelect.com
Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Continuous carry 5A, 8A, 10A (select one) 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms (only DSP)
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 213.1mm×266.0mm×203.0mm
Trepanning dimensions (W×H) 225mm×268.0mm, M5 screw
Mounting Flush mounted
Housing material Aluminum
Housing color Silver grey
Front side: IP40, up to IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or MODBUS
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or MODBUS
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 207
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


208 read more on www.nrelect.com www.nrelect.com
RCS-9659
Auto Synchronizer

RCS-9659 is a digital synchronizer that determines the proper


time to initiate closing of circuit breaker to parallel a generator
and bus, or to reclose a line. In order to fulfill different
application requirements, it offers three synchronizing modes:
automatic synchronizing, semi-automatic synchronizing and
• Automatic Synchronizing Mode: The closing manual synchronizing. By monitoring frequency, voltage and
command is issued via remote control center. phase angle, the RCS-9659 provides correction signals to the
RCS-9659 monitors slip frequency (frequency governor of prime mover and voltage regulator of generator
difference), slip speed, voltage difference and for voltage matching and frequency matching.
phase angle difference, issues control signal
to adjust frequency and voltage of generator
for voltage matching and frequency matching
and gives close command to the breaker at the
appropriate moment.

• S e m i - a u t o m a t i c S y n c h r o n i z i n g M o d e : T h e
closing command is issued manually to initiate
synchronism process, the other functions are
provided automatically just the same as automatic
synchronizing mode.

• Manual Synchronizing Mode: According to the


information provided by the digital frequency
meters and voltage meters, the operator controls
the speed and voltage of the generator as well as
the closure moment of the circuit breaker.

Features
Functions • Frequency tracking technology is adopted. By the aid of
that, real-time value of frequency, voltage and phase are
• Automatic synchronizing (25A) calculated with high precision on every sampling point.
• Semi-automatic synchronizing (25SA)
• The equipment uses an integral front panel and closed
• Manual synchronizing (25M) cabinet. High and low level signals are separated strictly.
• Multi-generator paralleling solution: capability of 10 circuit With well designed software anti-EMI facilities, the
breakers’ synchronization. To any of the circuit breakers, equipment’s capability of interference immunity is highly
frequency and voltage regulation can be done separately. enhanced. Furthermore, its electromagnetic radiation also
• Remote/local control paralleling mode satisfies relevant international standards.
• Blocking signal to other equipments • Flexible communication function
• Receive blocking signal from other equipments - 2 RS-485 communication rear ports conform to IEC 60870-5-103
protocol
• Communicate with substation automation system via
- 1 RS-485 communication rear ports for clock synchronization
serial port on IEC60870-5-103 or Ethernet port based on
- 4 rear Ethernet ports (optional), IEC 61850
IEC60870-5-103 or IEC61850.
• GPS clock synchronization – message, PPS (pulse • Monitoring and Metering
per second), PPM (pulse per minute), and IRIG-B - Event Recorder including 64 reports of status change of binary
synchronization. input, 64 self-supervision reports and 256 operating reports.
- Disturbance recorder including 64 fault reports, and 24
• Oscillograph, 8 cycles ahead of closing signal and 2 cycles
waveforms (The file format of disturbance recorder is compatible
after closing signal.
with international COMTRADE file.)

• Friendly Human Machine interface User Interface


- 1 RS-232 communication faceplate port for testing and setting
- 1 RS-232 communication rear ports or RS-485 for printer

Read more on the web


www.nrelect.com read more on www.nrelect.com 209
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1min
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177mm×291mm
Trepanning dimensions (W×H) 450mm×179.0mm, M6 screw
Mounting Flush mounted
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Read more on the web


210 read more on www.nrelect.com www.nrelect.com
Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Baud rate 4800 ~38400bps
Transmission distance < 1000m@4800bps
Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
RS-485 (EIA) Connector type ST
Baud rate 4800~38400bps
Transmission standard 100Base-FX
Optical Transmission distance <1500m
(optional) Optical fibre type Multi-mode fibre
Wave length 850/820nm
Fibre size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC 60870-5-103: 1997
Safety level Isolation to ELV level
Port number 4
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level
Port number 2
Ethernet Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Fiber Type Multi-mode
Optical
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level
Interface for local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download protection program
RS-232 (EIA)
Baud rate 4800~115200bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)

1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III


- Common mode 2.5kV
- Differential mode 1.0kV

Read more on the web


www.nrelect.com read more on www.nrelect.com 211
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
-For contact discharge 8.0kV
-For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
-Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
-Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
-Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests

Vibration IEC60255-21-1:1988, Class I


Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests

Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min


Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests

Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C


Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

212 read more on www.nrelect.com


Distribution Feeder Protection and Control

Distribution Feeder Protection Applications


How our products provide reliable, fast and accurate protection through our patented techniques are described in this section. Technical
data of different devices are provided in each relaying description.

Function Index

PCS-9691E
RCS-9613

RCS-9615

RCS-9625

RCS-9651

RCS-9629
RCS-9611

PCS-9651

PCS-9655
PCS-9611
Functional
Function
Code

Current differential protection 87F √


Phase-to-phase distance protection 21P √
Phase directional overcurrent protection 67P √ √ √
Phase overcurrent protection 50P/51P √ √ √ √ √ √ √ √
Zero sequence directional overcurrent protection 67N √ √
Zero sequence overcurrent protection 50N/51N √ √ √ √ √ √ √
Sensitive earth fault protection SEF √
Negative sequence overcurrent protection 50Q/51Q √ √
Under/Over voltage protection 27/59 √ √ √ √
Restricted earth fault protection REF √ √
Broken conductor detection 46BC √ √
Breaker failure protection 50BF √ √ √
Energizing protection 50E √
Frequency protection 81 √ √ √ √
Frequency rate-of-change element 7F √ √ √ √
Broken conduct detection BC √
Switch-on-to-fault protection SOTF √ √ √ √ √ √ √ √
Thermal overload protection 49 √ √ √ √ √ √ √
Cold load pick up logic CLP √
Auto-reclosing (three-pole) function 79 √ √ √ √ √ √
Synchronism check for auto-reclosing 25 √ √ √ √ √ √ √
Mechanical protection MR √
Configurable I/O and LED √
Programmable logic √
Power swing blocking function 68 √
Reserve energy auto-switching scheme ATS √ √ √ √
CT failure supervision CTS √ √ √ √ √ √
VT failure supervision VTS √ √ √ √ √ √ √ √ √ √
Circuit breaker monitoring √ √ √ √ √ √ √ √ √ √
GPS clock synchronization √ √ √ √ √ √ √ √ √
Remote control and measurements √ √ √ √ √ √ √ √ √ √
Fault Recorder FR √ √ √ √ √ √ √ √ √ √
Sequence of events recoding SOE √ √ √ √ √ √ √ √ √ √
Self diagnostic √ √ √ √ √ √ √ √ √ √
MODBUS protocol √ √ √ √ √
IEC60870-5-103 and RS-485 ports √ √ √ √ √ √ √ √ √ √
IEC61850-8-1 MMS & GOOSE for station bus √ √ √ √ √ √
IEC61850-9-2 SV & IEC61850-8-1 GOOSE for
√ √
process bus
DNP 3.0 LAN √ √

read more on www.nrelect.com 213


PCS-9611
Directional Overcurrent Protection

The PCS-9611 relay is a protection, control and monitoring


unit for various applications (such as overhead line,
underground cable and transformer etc.) on solidly
grounded, impedance grounded, Peterson coil grounded
and ungrounded system. The PCS-9611 features high
Functions performance functional library, programmable logic,
configurable I/O and integrated frequency-tracking.
Protection and control
The PCS-9611 is designed based on advanced multi-
• Four-stage directional overcurrent protection. (67P, 50P/51P)
processor platform, fully complying with IEC 61850 station
Phase overcurrent protection can be controlled by voltage
bus & process bus, supporting IEC 61850-8-1 MMS ,
control element, directional element and harmonic blocking
GOOSE and IEC 61850-9-2 Sampling Value..
element. IDMT curves complied with IEC and ANSI standard
are provided.

• Four-stage directional neutral/ground overcurrent protection.


(67N, 50/51N)
Up to two groups of neutral (ground) overcurrent protections • One-stage negative sequence overvoltage protection. (47)
are provided. It can be controlled by harmonic blocking Negative sequence overvoltage protection could be used to
element and directional element. IDMT curves complied with detect the unbalance situation.
IEC and ANSI standard are provided.
• Two-stage zero sequence overvoltage protection. (59N)
• Four-stage sensitive earth fault protection. (67SG/51SG) Zero sequence voltage could be set as external voltage
The sensitive earth fault protection can be controlled by injection or internal calculated voltage.
directional element. IDMT curves complied with IEC and
ANSI are provided. • Four-stage under-frequency protection, two-stage over-
frequency protection and four-stage rate-of-change of
• Two-stage undervoltage protection and two-stage over frequency (81)
voltage protection. (27/59) The rage-of-change of frequency could be set as increasing
The voltage input can select either phase voltage or phase- or decreasing via the setting, as well the duration used for
to-phase voltage. VT failure blocking is integrated in this rate-of-change calculation is setable.
protection.

214 read more on www.nrelect.com


• Breaker failure protection. (50BF) • Circuit breaker monitoring.
The relay will initiate re-tripping and adjacent breaker • CT failure supervision.
tripping during breaker failure. Four logics based on the
• VT failure supervision.
phase current and the circuit breaker state are selectable.
• Line voltage failure supervision.
• 4-shot three-pole auto-reclosing with sync--check and dead • Tripping circuit supervision.
line/bus check. (79/25) • Self diagnostic.
Synchronism check and dead bus or dead line check are
• Fault Recorder.
both provided for auto-reclosing.
• Total 1024 SOE, including tripping, alarm, binary input
• Two-stage negative sequence overcurrent protection change and human operation reports.
IDMT curves complied with IEC and ANSI are provided. • User-configurable high resolution oscillography of last 4
oscillograms. (Compatible with COMTRADE format)
• Broken conductor detection. (46BC)
The ratio of negative-sequence current to positive-sequence
Communications
current (Ι2/Ι1) is used to detect the broken conductor.
• Up to four 10Base-T/100Base-TX (RJ45) ports or two
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for
• Thermal overload element. (49)
non-time-critical message, IEC 60870-5-103 over TCP/IP or
This relay provides a thermal overload model using the RMS
DNP 3.0
value of current.
• Two RS-485 rear ports with IEC 60870-5-103
• Restricted Earth Fault Protection. (REF) • Up to Six 100Base-FX ports with IEC 61850-9-2 Sampling
Zero sequence differential protection is used as REF for Value and GOOSE for time-critical message
each Wye-connection winding to detect sensitive ground • One RS-485 rear port for clock synchronization
fault.
• One RS-232 rear port for printer
• Switch-onto-fault (SOTF) logic. • 1 faceplate RJ45 port for testing and setting
Switch-onto-fault logic is used to clear fault during manually- • Clock synchronization via pulse, IRIG-B and SNTP
closing or auto-reclosing.

• Cold load pickup logic (CLP) Features


The logic is used to inhibit the selected protective elements
• Modularized hardware design enables easy upgrade or
for an appointed duration, or to increase the settings of the
repaired. Various optional function modules can satisfy
selected protective elements.
various situations according to the different requirements of
users.
• Mechanical Protection
Up to 4 channels for mechanical protection are provided. It • This device can sample the analog values from the
receives the mechanical inputs from transformer tank and conventional CT/VT, or receive the sampled values from
issues the tripping or alarm outputs with or without time electronic CT/VT via merging unit.
delay.
• Overcurrent protection can be controlled by directional
• Interlocking logic for distribution busbar protection.
protection, , harmonic blocking element and voltage control
The protection of distribution busbar can be realized via
element..
GOOSE communication.
• The relay provides optional RTD input module and DC mA
• Remote and local tripping/closing of breaker. input module for temperature detection.
The breaker tripping/closing can be implemented remotely
• This device constantly measures and calculates a large
or locally.
amount of analog quantities, such as phase voltage, phase-
to-phase voltage, neutral voltage, phase current, neutral
• Interlocking logic of breaker control.
current, active power, reactive power, power factor and
The interlocking logic of breaker, isolator and earth switch is
frequency etc.
integrated.
• The connector type can be selected as plug in/out terminal
• Voltage and current drift auto adjustment. connector or screw terminal connector. The unique plug
The relay continually and automatically traces the voltage in/out terminal connectors from the relay rear panel to
and current drift and adjusts the zero point to a normal value. the terminal blocks on the rack or cabinet makes the on-
site commissioning and replacement much easier than the
• Frequency tracking. traditional screw terminals when you do the commissioning.
Frequency tracking is integrated to accommodate the
• Various methods of GPS time synchronization are supported
frequency shift in power system.
in this relay, including SNTP, IEEE1588 (V2), pulse per
second (PPS) and IRIG-B synchronization.
Monitoring and metering
• This device can communicate with a SAS or RTU via different
• Metering of current, voltage, active power, reactive power,
communication intermediates: Ethernet network, RS-485
power factor, energy, frequency, harmonic.

read more on www.nrelect.com 215


serial ports. The communication protocol of this device is 1024 latest control operation records, 1024 latest user
optional: IEC61850, IEC60870-5-103 or DNP3.0. operation records and 1024 latest records of time tagged
sequence of event (SOE) can be recorded.
• This device can detect the tripping circuit of the circuit
breaker and monitor the operation (close or trip) time of a • The relay is compatible with multiple protocols- IEC61850
circuit breaker by checking the auxiliary contacts of the circuit and IEC 60870-5-103 for station bus, GOOSE and
breaker. IEC61850-9-2 for process bus.

• Complete event recording function is provided: 64 latest


protection operation reports, 1024 latest supervision records,

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<10W (for conventional substation application)
Quiescent condition
<15W (for smart substation application)
Burden
<15W (for conventional substation application)
Operating condition
<20W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Application object For protection For metering
Rated current (In) 1A 5A 1A 5A
Linear to 30In 30In 2In 2In
continuously 3In 3In 2In 2In
for 10s 30In 30In 12In 12In
Thermal withstand capability
for 1s 100In 100In 30In 30In
for half a cycle 250In 250In 75In 75In
Burden <0.1VA/phase <0.2VA/phase <0.2VA/phase <0.4VA/phase

Analog Voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V
linear to 1~130V
continuously 120V
Thermal withstand capability 10s 200V
1s 250V
Burden < 0.10VA/phase @Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 48V 110V 125V 220V 250V
Rated current 1.2mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 55% rated voltage
Maximum permissive voltage 120% rated voltage
Withstand 2000Vac, 2800Vdc
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact

Read more on the web


216 read more on www.nrelect.com www.nrelect.com
Max system voltage 380Vac, 250Vdc 380Vac, 250Vdc
Voltage across open contact 1000V RMS for 1 minute 1200V RMS for 1 minute
5.0A @ 380Vac 8.0A @ 380Vac
Continuous carry
5.0A @ 250Vdc 8.0A @ 250Vdc
Pickup time <8ms <10ms
Drop-off time <5ms <8ms
6A for 3000ms 10A for 3000ms
Short duration current
15A for 500ms 20A for 500ms
0.6A @ 48Vdc, L/R=40ms 0.6A @ 48Vdc, L/R=40ms
Breaking capacity (L/R=40ms) 0.1A @ 110Vdc, L/R=40ms 0.3A @ 110Vdc, L/R=40ms
0.05A @ 220Vdc, L/R=40ms 0.2A @ 220Vdc, L/R=40ms
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 225.00×177.00×224.80 (unit: mm)
Trepanning dimensions (W×H) 226.00×178.00, M5 screw (unit: mm)
Mounting Flush mounted
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- Serial Port for RTU/SCADA
Port number 0 or 2
Baud rate 4800 ~ 115200bps
Protocol IEC60870-5-103:1997 or DNP3.0
Maximal capacity 32
Transmission distance <1000m @ 4800bps
Safety level Isolation to ELV level

- Ethernet Port for RTU/SCADA


Medium Parameters
Port number 2 or 4
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level
Ethernet Port number 2
Connector type SC
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Optical
Optical fiber type Multi-mode
Wavelength 1300
Transmission distance <1500
Protocol IEC60870-5-103:1997 or IEC61850

- Process Level Interface


Characteristic Glass optical fiber
Optical fiber type Multi-mode
Connector type LC ST
Wave length 820nm 1310nm
Transmission distance <2000m
Minimum transmission power -20dBm
Reception sensitivity -30dBm

Read more on the web


www.nrelect.com read more on www.nrelect.com 217
- Print Port
Port number 1
Type RS-232
Baud Rate 4800 ~ 115200bps
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Port number 1
Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


218 read more on www.nrelect.com www.nrelect.com
RCS-9611
Feeder Management Relay

The RCS-9611 is a protection, control and monitoring


unit with auto-reclosing for distribution feeders on solidly
grounded, impedance grounded, Peterson coil grounded and
ungrounded system. It is fully compatible with IEC 61850
communication.

• Circuit breaker monitoring.


• CT failure detection logic.
• VT failure detection logic.
• Synchro-check voltage failure supervision.
• Voltage and current drift auto adjustment.
• Self diagnostic.
• GPS clock synchronization.
• Fault Recorder.
• 64 tripping reports and 256 SOE (Sequence of Events)
records.
• High resolution oscillography of last 8 oscillograms
(compatible with international COMTRADE format)
• Rear communication ports: Ethernet with IEC 61850,
2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.

Functions
• Three-stage phase overcurrent protection. (50P/51P) Features
• Three-stage directional phase overcurrent protection. (67P)
• Definite time and inverse time characteristics of overcurrent
• Three-stage neutral overcurrent protection. (67N) protection are both provided.
• Three-stage zero sequence overcurrent protection. (50/51N)
• Overcurrent protection could be supervised by directional
• Time negative sequence overcurrent protection. (51Q) element and voltage elements.
• Under/Overvoltage protection. (27/59)
• Undefrequency protection that can be supervised by rate-of-
• Breaker failure protection. (50BF) change elements would shed loads before out-of-step.
• Underfrequency protection. (81)
• The relay constantly measures a large mount of analog
• Frequency rate-of-change protection. (81R) quantities, such as phase voltage, phase-to-phase voltage,
• Thermal overload protection. (49) neutral voltage, phase current, neutral current, active power,
• Arc-flash protection. (51PAF) reactive power, power factor and frequency.

• Frequency rate-of-change element. (7F) • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a


• Breaker failure protection. (51BF) measurement, calculation and logic discrimination could be
done within one sampling period. The event recording and
• Switch-onto-fault (SOTF) logic.
protection logic calculation are completed simultaneously.
• Synchronism check. (25)
• The relay provides GPS clock synchronization, including
• Auto-reclosing (three-pole). (79)
message, second pulse and IRIG-B synchronization.
• Earth fault detection. (64)
• The relay can be integrated in SAS or RTU. The relay is
• Remote control and measurement.
equipped with Ethernet ports with the IEC 61850 protocol
• Tripping circuit supervision. and RS-485 ports with IEC 60870-5-103 protocol.

Read more on the web


www.nrelect.com read more on www.nrelect.com 219
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


220 read more on www.nrelect.com www.nrelect.com
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 221
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


222 read more on www.nrelect.com www.nrelect.com
RCS-9613
Feeder Differential Relay

The RCS-9613 relay is a current differential protection and


overcurrent protection, control and monitoring unit with
auto-reclosing function for distribution feeder lines in solidly
grounded, impedance grounded, Peterson coil grounded and
ungrounded system. This relay is suited to be flush mounted
into a control panel.

• Voltage and current drift auto adjustment.


• Self diagnostic.
• GPS clock synchronization.
• Fault Recorder.
• 64 tripping reports and 256 SOE (Sequence of Events)
records.
• High resolution oscillography of last 8 oscillograms
(compatible with international COMTRADE format)
• Rear communication ports: Ethernet with IEC 61850,
2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.

Features
• Definite time and inverse time characteristics of overcurrent
Functions protection are both provided.

• Overcurrent protection could be supervised by directional


• Current differential protection. (87F)
element voltage elements.
• Three-stage phase overcurrent protection. (50P/51P)
• Underfrequency protection that could be supervised by rate-
• Three-stage directional phase overcurrent protection. (67P)
of-change element would shed loads before out-of-step.
• Three-stage zero sequence overcurrent protection.
(50N/51N) • The relay constantly measures a large amount of analog
quantities, such as phase voltage, phase-to-phase voltage,
• Underfrequency protection. (81U)
neutral voltage, phase current, neutral current, active power,
• Frequency rate-of-change element. (7F) reactive power, power factor and frequency.
• Switch-onto-fault (SOTF) logic.
• The relay can monitor and record the operating times of
• Overload protection. (49) opening/closing circuit breakers.
• Synchronism check. (25)
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Auto-reclosing (three-pole). (79) measurement, calculation and logic discrimination can be
• Earth fault detection. (64) finished within one sampling period. The event recording and
• Remote control and measurent. protection logic calculation are completed simultaneously.

• Tripping circuit supervision. • The relay provides GPS clock synchronization, including
• CT failure detection logic. message, second pulse and IRIG-B synchronization.

• VT failure detection logic. • The relay is equipped with Ethernet ports with the IEC 61850
• Synchro-check voltage failure supervision. protocol and RS-485 ports with IEC 60870-5-103 protocol.

Read more on the web


www.nrelect.com read more on www.nrelect.com 223
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


224 read more on www.nrelect.com www.nrelect.com
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 225
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


226 read more on www.nrelect.com www.nrelect.com
RCS-9615
Feeder Management Relay

The RCS-9615 provides distance protection and overcurrent


protection with auto-reclosing function for distribution feeder
lines in solidly grounded, impedance grounded, Peterson coil
grounded and ungrounded system. This relay is suited to be
flush mounted into a control panel.

• Synchro-check voltage failure adjustment.


• Voltage and current drift auto regulation.
• Self diagnostic.
• GPS clock synchronization.
• Fault Recorder.
• 64 tripping reports and 256 SOE (Sequence of Events)
records.
• High resolution oscillography of last 8 oscillograms
(compatible with international COMTRADE format)
• Rear communication ports: Ethernet with IEC 61850,
2 RS-485 with IEC 60870-5-103, 1 RS-485 for clock
synchronization, 1 RS-232 for communication to printer.

Features
• The built-in reliable power swing blocking logic can properly
supervise the distance elements during a power swing. The
Functions power swing blocking logic can make the relay untrip for an
external fault during a power swing and pickup for an internal
• Three-zone phase-to-phase distance protection. (21P) fault.
• Two-stage overcurrent protection. (50P/51P)
• Under frequency protection that could be supervised by rate-
• Zero sequence overcurrent protection. (50N/51N) of-change element would shed loads before out-of-step.
• Underfrequency protection. (81U)
• The relay constantly measures a large mount of analog
• Frequency rate-of-change element. (7F)
quantities, such as phase voltage, phase-to-phase voltage,
• Switch-onto-fault (SOTF) logic. neutral voltage, phase current, neutral current, active power,
• Overload protection. (49) reactive power, power factor and frequency.
• Synchronism check. (25)
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Auto-reclosing (three-pole). (79) measurement, calculation and logic discrimination can be
• Power swing blocking. (68) finished within one sampling period. The event recording and
• Accelerated tripping during unsymmetrical faults. protection logic calculation are completed simultaneously.
• Accelerated tripping during double circuit line faults. • The relay provides GPS clock synchronization, including
• Remote control and measurement. second pulse and IRIG-B synchronization.
• Tripping circuit supervision. • The relay is equipped with Ethernet ports with the IEC 61850
• CT failure detection logic. protocol or IEC 60870-5-103 protocol and RS-485 ports with
• VT failure detection logic. IEC 60870-5-103 protocol.

Read more on the web


www.nrelect.com read more on www.nrelect.com 227
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


228 read more on www.nrelect.com www.nrelect.com
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 229
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


230 read more on www.nrelect.com www.nrelect.com
RCS-9625
Feeder Management Relay

The RCS-9625 provides directional overcurrent protection,


control and monitoring functions for feeders in power plants
in solidly grounded, impedance grounded, Peterson coil
grounded and ungrounded system. It is suited to be flush
mounted into a control panel.

• 64 Self-check alarm records, 64 operating alarm records and


8 Disturbance records FR.
• 256 SOE records, latest records of following elements state
changing: operating abnormality alarm elements, self-check
alarm elements, protection elements, binary input elements.
• Circuit breaker operating time monitoring.

Auxiliary Testing
• Virtual SOE records generation
• Virtual measurement values generation
• Virtual tripping reports generation
• Virtual fault wave records generation

Functions
Features
Protection and control
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Overcurrent protection (50P/51P)
measurement, calculation and logic discrimination can be
• Zero sequence overcurrent protection (50N/51N) finished within one sampling period. The event recording and
• Directional overcurrent protection. (67P) protection logic calculation can be finished simultaneously.
• Voltage control element (VCE) • Definite time and inverse time of overcurrent protection are
• One shot three poles auto-reclose (79) both provided.
• Synchronism check function (25) • Overcurrent protection can be controlled by voltage element.
• Switch-on-to-fault logic (SOTF)
• This relay constantly measures and calculates a large
• Earth fault protection (64) amount of analog quantities, such as phase-to-phase
• Thermal overload protection (49) voltage, phase current, neutral current, active power, reactive
• Voltage and current drift auto adjustment power, power factor and frequency.
• Self diagnostic • It can monitor and record the operating time of opening/
• Bus and feeder voltage transformer supervision (VTS) closing circuit breakers.
• Current transformer supervision (CTS) • Various methods of GPS clock synchronization, including
• Rear communication ports: printer message, pulse per second, and IRIG-B synchronization.
• Rear communication ports: RS-485 • This relay is equipped with two EIA RS-485 standardized
• Time synchronization port interfaces and two Ethernet interfaces. The Ethernet interface
has two alternative designs: electrical or optical.

Management • The relay can communicate with SAS or RTU using


• Circuit breaker status monitoring IEC60870-5-103 and MODBUS communication protocols.
• Remote control and measurements. • Fault and disturbance record function: 64 latest fault reports,
• Tripping circuit supervision. 8 latest fault wave (up to 15s), 64 user operating records
of users to equipment, and 256 records of time tagged
• Multiple setting groups
sequence of event can be recorded.
• 64 Trip records
Read more on the web
www.nrelect.com read more on www.nrelect.com 231
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6, 1988
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 220VDC 125VDC 250VDC
Pickup voltage 77VDC 154VDC 87.5VDC 175VDC
Dropout voltage 60.5VDC 121VDC 68.8VDC 137.5VDC
Maximum permitted voltage 150V 300V 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000Vac rms for 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
Dropout time(Typical/Max) 8ms/10ms 4ms/10ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

DC Output
Output range 4 ~ 20mA
Max load resistance 500ohm
Max output voltage 10V
Atmospheric Environment
Standard IEC60255-6:1988
Operating temperature range -25 °C ~ +55 °C
Transport and storage temperature range -40 °C ~ +70 °C
Permissible humidity 5% ~ 95%, condensation not permissible

Mechanical Specifications
Enclosure dimensions (W×H×D) 142.4×266.0×203.0 (unit: mm)
Trepanning dimensions (W×H) 154×268.0 (unit: mm), M5 screw
Mounting Way Flush mounted

Read more on the web


232 read more on www.nrelect.com www.nrelect.com
Local control panel Small control module: 3 LED indicators, a 9-key keypad and a 160×80-dot LCD
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2007 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz /450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2008 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line

Read more on the web


www.nrelect.com read more on www.nrelect.com 233
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m for 1 minute
1000A/m for 3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:1974, 16 hours at +55°C
Dry cold test IEC60068-2-1:1990, 16 hours at -25°C
IEC60068-2-30:1980, two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


234 read more on www.nrelect.com www.nrelect.com
PCS-9651
Automatic Transfer Relay

The PCS-9651 continuously monitors the power supply


lines of load and provides automatic transfer logic from main
source to backup source. If a fault occurred in any of power
supply lines, the PCS-9651 can discriminate the abnormal
state and switch over the load from the faulty line to the
normal line, to guarantee the continuous power supply to
the load. Up to four typical switching modes are provided
for selection. Besides, the remote/local control function is
integrated in the unit.

non-time-critical message, IEC 60870-5-103 over TCP/IP or


DNP 3.0
• Two RS-485 rear ports with IEC 60870-5-103
• Up to Six 100Base-FX ports with IEC 61850-9-2 Sampling
Value and GOOSE for time-critical message
• One RS-485 rear port for clock synchronization
• One RS-232 rear port for printer
• 1 faceplate RJ45 port for testing and setting
• Clock synchronization via pulse, IRIG-B and SNTP

Features
• The voltages inputs and external binary inputs connecting to
breaker auxiliary contacts are used to detect the abnormal
state.

• It provides the RJ-45 faceplate port for testing and setting to


Functions make commissioning and maintenance easier.
• Automatic transfer switch (ATS) • The device could receive the analog values from conventional
• Remote/local control function CT/VT and electronic CT/VT via merging unit.
• Circuit breaker status monitoring • The connector type can be selected as plug in/out terminal
• Tripping circuit supervision (TCS) connector or screw terminal connector. The unique plug in/
• VT circuit supervision (VTS) out terminal connectors from the relay rear panel to the
terminal blocks on the rack or cabinet makes the onsite
• Self diagnostic
commissioning and replacement much easier than the
• Voltage drift auto adjustment traditional screw terminals when you do the commissioning.
• 64 Operation reports
• Various methods of GPS time synchronization are supported
• 1024 supervision alarm records in this relay, including SNTP, IEEE1588 (V2), pulse per
• 1024 control operation records second (PPS) and IRIG-B synchronization.
• 1024 user operating logs • The PCS-9651 is fully complied with IEC 61850 and provides
• 64 fault and disturbance records (FDR) the independent interfaces for station bus and process bus
• 1024 latest SOE records respectively, supporting IEC 61850-8-1 MMS , GOOSE and
IEC 61850-9-2 Sampling Value.
• Up to four 10Base-T/100Base-TX (RJ45) ports or two
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for

Read more on the web


www.nrelect.com read more on www.nrelect.com 235
Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<10W (for conventional substation application)
Quiescent condition
<15W (for smart substation application)
Burden
<15W (for conventional substation application)
Operating condition
<20W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Application object For protection For metering
Rated current (In) 1A 5A 1A 5A
Linear to 30In 30In 2In 2In
continuously 3In 3In 2In 2In
for 10s 30In 30In 12In 12In
Thermal withstand capability
for 1s 100In 100In 30In 30In
for half a cycle 250In 250In 75In 75In
Burden <0.1VA/phase <0.2VA/phase <0.2VA/phase <0.4VA/phase

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 48V 110V 125V 220V 250V
Rated current 1.2mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 55% rated voltage
Maximum permissive voltage 120% rated voltage
Withstand 2000Vac, 2800Vdc
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
Max system voltage 380Vac, 250Vdc 380Vac, 250Vdc
Voltage across open contact 1000V RMS for 1 minute 1200V RMS for 1 minute
5.0A @ 380Vac 8.0A @ 380Vac
Continuous carry
5.0A @ 250Vdc 8.0A @ 250Vdc
Pickup time <8ms <10ms
Drop-off time <5ms <8ms
6A for 3000ms 10A for 3000ms
Short duration current
15A for 500ms 20A for 500ms
0.6A @ 48Vdc, L/R=40ms 0.6A @ 48Vdc, L/R=40ms
Breaking capacity (L/R=40ms) 0.1A @ 110Vdc, L/R=40ms 0.3A @ 110Vdc, L/R=40ms
0.05A @ 220Vdc, L/R=40ms 0.2A @ 220Vdc, L/R=40ms
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Automatic Transfer Function


Voltage setting of live check 70.00V ~ 120.00V
Voltage setting of dead check 2.00V ~ 80.00V
Voltage setting of dead check when closing 2.00V ~ 80.00V
Tolerance of voltage setting ≤ 2.5% Setting or 0.10V, whichever is greater
Current setting of dead check 0.02×In ~ 2.00×In
Tolerance of current setting ≤ 2.5% Setting or 0.01×In, whichever is greater
Time setting 0.00s ~ 30.00s
Tolerance of time setting ≤ 1% Setting + 35ms

Read more on the web


236 read more on www.nrelect.com www.nrelect.com
Mechanical Specifications
Enclosure dimensions (W×H×D) 225.00×177.00×224.80 (unit: mm)
Trepanning dimensions (W×H) 226.00×178.00, M5 screw (unit: mm)
Mounting Flush mounted
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2
Ambient Temperature and Humidity Range
Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

communication Port
- Serial Port for RTU/SCADA
Port number 0 or 2
Baud rate 4800 ~ 115200bps
Protocol IEC60870-5-103:1997 or DNP3.0
Maximal capacity 32
Transmission distance <1000m @ 4800bps
Safety level Isolation to ELV level

- Ethernet Port for RTU/SCADA


Medium Parameters
Port number 2 or 4
Connector type RJ-45
Transmission rate 100Mbits/s
Ethernet Electrical Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Ethernet Optical
Optical fiber type Multi-mode
Wavelength 1300
Transmission distance <1500
Protocol IEC60870-5-103:1997 or IEC61850

- Process Level Interface


Characteristic Glass optical fiber
Optical fiber type Multi-mode
Connector type LC ST
Wave length 820nm 1310nm
Transmission distance <2000m
Minimum transmission power -20dBm
Reception sensitivity -30dBm

- Print Port
Port number 1
Type RS-232
Baud Rate 4800 ~ 115200bps
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Port number 1
Type RS-485
Transmission distance <500m
Maximal capacity 32

Read more on the web


www.nrelect.com read more on www.nrelect.com 237
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


238 read more on www.nrelect.com www.nrelect.com
RCS-9651
Automatic Transfer Relay

RCS-9651 relay is an automatic transfer relay used to


prevent the interruption of power supply and to provide the
protection of bus section breaker. It is suitable for busbar of
any voltage level and different bus arrangements (including
inner bridge connection, single busbar, single busbar with
section and other arrangements).

Functions
• Rear communication ports: Ethernet with IEC 61850 or IEC
• Automatic transfer logic
60870-5-103, 2 RS-485 with IEC 60870-5-103, 1 RS-485 for
• Two-level overcurrent protection. (50P/51P)
clock synchronization, 1 RS-232 for communication to printer.
• Zero sequence overcurrent protection. (50N/51N)
• Overcurrent protection for energizing a faulty bus or a faulty
line. (50E)
Features
• Overload shedding function.
• Auto-switching control scheme could be blocked by voltage
• Synchronism check. (25)
element, current element or state of breakers.
• Remote control and measurements.
• Energization protection algorithm is reliable, practical and
• Circuit breaker monitoring.
adaptive.
• CT failure detection logic.
• Overcurrent protection can be supervised by voltage
• VT failure detection logic.
elements.
• Tripping circuit supervision.
• The RCS-9651 relay constantly measures a large mount
• Current drift auto adjustment.
of analog quantities, such as phase current, active power,
• Self diagnostic test. reactive power and power factor.
• GPS clock synchronization.
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Fault Recorder. measurement, calculation and logic discrimination could be
• 64 tripping reports and 256 SOE (Sequence of Events) done within one sampling period. The event recording and
records. protection logic calculation are completed simultaneously.
• High resolution oscillography of last 8 oscillograms. • The relay provides GPS clock synchronization, including
(Compatible with international COMTRADE format) message, second pulse and IRIG-B synchronization.

• The relay is equipped with Ethernet ports with the IEC 61850
protocol and RS-485 ports with IEC 60870-5-103 protocol.

Read more on the web


www.nrelect.com read more on www.nrelect.com 239
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


240 read more on www.nrelect.com www.nrelect.com
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 241
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


242 read more on www.nrelect.com www.nrelect.com
RCS-9629
Automatic Transfer Relay

The RCS-9629 is an integrated automatic transfer relay with


transfer function, bus section protection, control function and
monitoring which can be applied to all kinds of power plants.
It can be flush mounted into a control panel.

• 64 User operating records


• 8 Disturbance records FR
• 256 SOE records, latest records of following elements state
changing: operating abnormality alarm elements, self-check
alarm elements, protection elements, binary input elements
• Rear communication ports: printer
• Rear communication ports: RS-485/Ethernet
• Time synchronization port

Features
• O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
measurement, calculation and logic discrimination can be
finished within one sampling period. The event recording and
Functions protection logic calculation can be finished simultaneously.

• The device provides completed solution for the power supply


Protection and control (PS) switch in a power plant.
• Automatic transfer logic (ATS)
• The automatic transfer logic and relevant protection elements
• Instantaneous overcurrent protection (50P)
are integrated in this device independently. It can be enabled
• Time overcurrent protection (51P) or disabled freely according to the practical engineering
• Switch-onto-fault protection (SOTF) demand.
• Voltage control element (VCE) • This relay constantly measures and calculates a large
• Synchronism check function (25) amount of analog quantities, such as phase-to-phase voltage
• Voltage and current drift auto adjustment and system frequency.

• Self diagnostic • Multiple GPS clock synchronization, including message,


• Voltage transformer supervision (VTS) pulse per second, and IRIG-B synchronization.

• This relay is equipped with two EIA RS-485 standardized


Management interfaces and up to three Ethernet interfaces. Two alternative
designs of Ethernet interfaces are provided: electrical or
• Circuit breaker status monitoring
optical.
• Remote control and measurement.
• It communicates with SAS or RTU using IEC60870-5-103
• Multiple setting groups.
and MODBUS communication protocols.
• Tripping circuit supervision.
• Fault and disturbance record function: 64 latest fault reports,
• 64 Trip records
8 latest fault wave (up to 15s), 64 user operating records
• 64 Self-check alarm records of users to equipment, and 256 records of time tagged
• 64 Operating alarm records sequence of event can be recorded.

Read more on the web


www.nrelect.com read more on www.nrelect.com 243
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6, 1988
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs:
Rated Voltage 110VDC 220VDC 125VDC 250VDC
Pickup voltage 77VDC 154VDC 87.5VDC 175VDC
Dropout voltage 60.5VDC 121VDC 68.8VDC 137.5VDC
Maximum permitted voltage 150V 300V 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000Vac rms for 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
Dropout time(Typical/Max) 8ms/10ms 4ms/10ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum
DC Output
Output range 4 ~ 20mA
Max load resistance 500ohm
Max output voltage 10V

Atmospheric Environment
Standard IEC60255-6:1988
Operating temperature range -25 °C ~ +55 °C
Transport and storage temperature range -40 °C ~ +70 °C
Permissible humidity 5% ~ 95%, condensation not permissible

Mechanical Specifications
Enclosure dimensions (W×H×D) 142.4×266.0×203.0 (unit: mm)
Trepanning dimensions (W×H) 154×268.0 (unit: mm), M5 screw
Mounting Way Flush mounted

Read more on the web


244 read more on www.nrelect.com www.nrelect.com
Local control panel Small control module: 3 LED indicators, a 9-key keypad and a 160×80-dot LCD
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Ethernet
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Optical Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Fiber Type Multi-mode
Wavelength 1300nm
Ethernet Optical
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2007 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz /450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 245
Fast transient disturbance tests IEC60255-22-4:2008 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m for 1 minute
1000A/m for 3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:1974, 16 hours at +55°C
Dry cold test IEC60068-2-1:1990, 16 hours at -25°C
IEC60068-2-30:1980, two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


246 read more on www.nrelect.com www.nrelect.com
PCS-9655
High Speed Transfer Device

The PCS-9655 high speed transfer device is used in power


plants and substations to ensure the continuous and reliable
power supply for generators and busbar. This device
supports flush mounted into a control panel.

• Switch-onto fault protection


• Voltage and current drift auto adjustment
• Self supervision
• Voltage transformer supervision

Management
• Circuit breaker status monitoring
• Circuit breaker control
• 64 Fault records and 64 Disturbance records
• 1024 SOE records, latest records of following elements
state changing: operating abnormality alarm elements, self-
check alarm elements, protection elements and binary input
elements.
In normal operation, the power supply of busbar is provided by
the main power supply branch, and the standby power supply is
ready for switching. If circuit breaker CB3 is closed, the standby
power supply is in hot standby state; if tcircuit breaker CB3 is Features
opened, the standby power supply is in cold standby state.
• This device can provide all kinds of switching functions:
If the main power supply has fault, the PCS-9655 will trip normal manual switching, accident switching, loss-of-busbar-
circuit breaker “CB1”, and the voltage of busbar is lost. Due to voltage switching and circuit breaker mal-operation switching.
the mechanical inertia of motor load of busbar, the composite
• This device also provides useful auxiliary functions such as
feedback voltage of busbar is decaying gradually. In this
two stages of undervoltage load shedding protection and the
procedure, if the standby power supply is put into service at
SOTF overcurrent protection.
an improper moment, the voltage difference between busbar
residual voltage and standby power supply voltage will have a • The PCS-9655 adopts automatic frequency tracking
greater impact on other equipments in the power plant. Then technology in the busbar voltage measurement to calculate
the switching operation will be failed, and the busbar voltage is the frequency and the phase of busbar voltage fast and
lost absolutely. accurately.

The PCS-9655 high speed transfer device can select the optimal • The PCS-9655 supports different GPS clock synchronization,
moment for switching the standby power supply into service to including communication message, pulse per second, and
ensure the safety and reliability of switching operation. IRIG-B synchronization.

• The PCS-9655 can communicate with SAS or RTU using


IEC60870-5-103 or Modbus.
Functions • Fault and disturbance recording function: 64 latest fault
• Normal manual switching function reports and 64 fault waves are provided and the duration of a
fault ware is up to 32s. The fault wave format is compatible to
• Accident switching function
COMTRADE.
• Loss-of-busbar-voltage switching function
• The PCS-9655 can record 1024 Self-check alarm, 1024
• Circuit breaker unexpected tripping switching function
Operating alarm and 1024 binary input change during
• Undervoltage load shedding switching function operation.

Read more on the web


www.nrelect.com read more on www.nrelect.com 247
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 30 W
Burden
Operating condition < 50 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 482.6×177.0×291.0 (unit: mm)
Trepanning dimension (W×H) 450.0×179.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


248 read more on www.nrelect.com www.nrelect.com
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 249
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


250 read more on www.nrelect.com www.nrelect.com
PCS-9691E
Overcurrent Protection

The PCS-9691E overcurrent relay is designed for fast and


selective protection, control and monitoring of feeders, shunt
capacitor banks, reactors or motors etc. in directly grounded,
impedance grounded, Peterson coil grounded or ungrounded
system. This device is suited to be flush mounted into a
control panel.

Metering and monitoring


• Tripping/Closing circuit supervision
• Circuit breaker state monitoring
• Operation time supervision of breaker
• 256 SOE records, including tripping, alarm, change of binary
inputs and self-check.
• Eight (8) wave records, up to 4.5 seconds for each wave
record, compatible with COMTRADE format.
• Supervision of tripping time, CBF starting current, CB
switching counter, CB travelling time and internal relay fault.

Control
• 10 configurable binary inputs
• 7 binary outputs for DC voltage (including 4 configurable
contacts), 9 binary outputs for AC voltage (including 6
configurable contacts)
Functions • 8 LEDs, including 5 configurable LEDs
• Local/remote opening/closing logic of breaker
Protection
• Faceplate buttons for local control of breaker
• Three-stage phase overcurrent protection. (50/51P)
• Three-stage neutral overcurrent protection. (50/51N)
Communication and HMI
• Three-stage negative sequence overcurrent protection. • One RS-232 port for testing
(50/51Q)
• Two RS-485 ports for communication with SCADA
• Directional ground time overcurrent protection. (67G)
• IEC 60870-5-103 DNP 3.0 serial, and MODBUS protocol
• Breaker failure protection. (51BF)
• RCS-PC assistant software for testing
• Thermal overload protection. (49)
• Clock Synchronization
• Broken conductor protection. (46BC)
• Undervoltage/overvoltage protection. (27/59)
• Multi-slot three-pole auto-reclosing (Up to 3 slots). (79) Features
• Ten (10) available curves complied with ANSI and IEC
• O n t h e p r e m i s e o f 3 2 s a m p l e s p e r c y c l e , a l l d a t a
standard. (IDMT)
measurement, calculation and logic discrimination could be
• Thermal model overload curve. done within one sampling period. The event recording and
• Voltage transformer supervision. (VTS) protection logic calculation are completed simultaneously.
• Current transformer supervision. (CTS) • Definite time and inverse time of phase overcurrent protection
• Current drift auto-adjustment are both provided.

Read more on the web


www.nrelect.com read more on www.nrelect.com 251
• Definite time and inverse time of zero sequence overcurrent • Event recording function: 32 latest fault reports (up to 8 records
protection are both provided in a report), 64 alarm records and 256 records of time tagged
sequence of event can be recorded.
• This relay constantly measures and calculates analog
quantities for metering including phase current and zero • Fault and disturbance recording function: 16 latest fault waves,
sequence current. and the fault and disturbance file format is COMTRADE, see
Section 2.3.3 for more details.
• This relay is equipped with two EIA RS-485 standardized
electrical interfaces for uplink communication. • This device can store settings, history reports and fault waves
in a 2Mbit FRAM, which makes these information does not be
• This relay can communication with SAS or RTU, the
lost even the power supply is switched off.
communication protocol of this device is IEC60870-5-103,
Modbus or DNP3.0.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 10 W
Burden
Operating condition < 15 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.5VA/phase @ In < 0.1VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 57.7V (Phase) 63.5V (Phase)
linear to 100 V 115V
continuously 69.3V 76.3V
Thermal withstand capability 10s 115.5V 127.1V
1s 144.4V 158.9V
Burden <0.5 VA/phase @ Un <0.5 VA/phase @ Un

Binary Inputs
Rated Voltage 110VDC 220VDC
Pickup voltage 77VDC 154VDC
Dropout voltage 60.5VDC 121VDC
Maximum permitted voltage 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute

Read more on the web


252 read more on www.nrelect.com www.nrelect.com
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 188.92×177.00×165.31 (unit: mm)
Trepanning dimension (W×H) 173.0×178.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 19200bps
Transmission distance < 500m@4800bps
RS-485 (EIA) Maximal capacity 32
IEC60870-5-103:1997, , MODBUS or DNP 3.0
Protocol
serial
Safety level Isolation to ELV level
Interfaces for debugging through RCS-PC software
Port number 1
RS-232 (EIA) Baud rate 19200bps
Safety level Isolation to ELV level
Port number 2
RS-485 (EIA) Baud rate 4800 ~ 19200bps
Safety level 32

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 253
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

254 read more on www.nrelect.com


Motor Protection
Motor Protection Applications
How our products provide reliable, fast and accurate protection through our patented techniques are described in this section. Different
motor protection devices and technical data are provided in the end of each chapter.

Functional
Function RCS-9641 RCS-9642 RCS-9626 RCS-9627
Code
Protection for Motor
Unrestraint current differential protection 87U √ √
Percentage restraint current differential protection 87P √ √
Phase overcurrent protection 50P/51P √ √ √ √
Zero sequence overcurrent protection 50N/51N √ √
Negative sequence overcurrent protection 50Q/51Q √ √ √ √
Over voltage protection 59 √ √
Under voltage protection 27 √ √ √ √
Ground detector protection 64 √ √ √ √
Thermal overload protection 49 √ √ √ √
Miscellaneous
Mechanical protection MR √ √ √ √
CT failure detection logic CTS √ √ √ √
VT failure detection logic VTS √ √ √ √
GPS clock synchronization √ √ √ √
Remote control and measurements √ √ √ √
Fault Recorder FR √ √ √ √
IEC 60870-5-103 protocol √ √ √ √
MODBUS protocol √ √

Read more on the web


www.nrelect.com read more on www.nrelect.com 255
RCS-9641
Motor Management Relay

The RCS-9641 is a digital protection, control and monitoring


unit used for the protection of small capacity motors.
It provides overcurrent protection, over/under voltage
protection and ground protection for asynchronous motor. It
is fully compatible with IEC 61850 communication.

• Fault Recorder.
• 64 tripping reports and 256 SOE (Sequence of Events)
records.
• High resolution oscillography of last 8 oscillograms
(compatible with international COMTRADE format)
• Rear communication ports: Up to three Ethernet ports with
IEC 61850, 2 RS-485 ports with IEC 60870-5-103 protocol,
one RS-485 for clock synchronization, one RS-232 for
communication to printer.

Features
• Definite time and inverse time characteristics of inverse
sequence overcurrent protection are both provided.

Functions • The relay can monitor and record the operating times of
opening/closing circuit breakers.
• Motor startup supervision. (66) • The inverse sequence overcurrent protection is used for
• Two-stage overcurrent protection. (50P/51P) inter-turn fault and unbalance fault, including open pole or
• Two-stage inverse sequence overcurrent protection. (50Q/ reverse phase sequence.
51Q) • The stator ground detector protection constitutes of zero
• Definite time zero sequence overcurrent protection. (50N) sequence overcurrent protection and zero sequence voltage
• Stator ground protection. (64) protection.

• Under voltage protection. (27) • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a


• Over voltage protection. (59) measurement, calculation and logic discrimination can be
done within one sampling period. The event recording and
• Thermal protection. (49)
protection logic calculation are completed simultaneously.
• Mechanical protection. (MR)
• The relay provides GPS clock synchronization, including
• Overload protection.
message, second pulse and IRIG-B synchronization.
• Remote control and measurements.
• The HMI interface with a LCD and a 9-button keypad on the
• Tripping circuit supervision.
front panel is friendly to users.
• Circuit breaker monitoring.
• The format of event report is compatible with international
• CT failure detection logic.
COMTRADE file.
• VT failure detection logic.
• The relay can be integrated in SAS or RTU. The relay is
• Voltage and current drift auto adjustment.
equipped with Ethernet ports with the IEC 61850 protocol
• Self diagnostic and RS-485 ports with IEC 60870-5-103 protocol.
• GPS clock synchronization.

Read more on the web


256 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


www.nrelect.com read more on www.nrelect.com 257
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


258 read more on www.nrelect.com www.nrelect.com
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 259
RCS-9642
Motor Management Relay

The RCS-9642 relay is a digital protection, control and


monitoring unit used for the protection of large capacity
motors. It provides current differential protection, overcurrent
protection, under/over voltage protection for asychronous
motor. It is fully compatible with IEC 61850 communication.

• 64 tripping reports and 256 SOE (Sequence of Events)


records.
• High resolution oscillography of last 8 oscillograms
(compatible with international COMTRADE format)
• Rear communication ports: Up to three Ethernet ports with
IEC 61850, 2 RS-485 ports with IEC 60870-5-103 protocol,
one RS-485 for clock synchronization, one RS-232 for
communication to printer.

Features
• The typical operating time of differential protection is less
than 25ms.It is the main protection for phase fault.
• Definite time and inverse time characteristics of inverse
sequence overcurrent protection are both provided.
• Inverse sequence overcurrent protection is used for inter-
turn fault and unbalance fault, including open pole or reverse
Functions phase sequence.
• Stator ground detector protection constitutes of zero
• Unrestraint current differential protection. (87UM)
sequence overcurrent protection and zero sequence voltage
• Percentage restraint current differential protection. (87PM) protection.
• Three-stage overcurrent protection. (50P, 51P)
• The RCS-9642 relay constantly measures a large mount of
• Three-stage inverse sequence overcurrent protection. (50Q, analog quantities, such as phase voltage, phase-to-phase
51Q) voltage, phase current, active power, reactive power, power
• Stator ground detector protection. (64) factor and frequency.
• Under voltage protection. (27) • The relay can monitor the status of circuit breaker.
• Over voltage protection. (59) • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Thermal protection. (49) measurement, calculation and logic discrimination could be
• Mechanical protection. (MR) done within one sampling period. The event recording and
protection logic calculation are completed simultaneously.
• Overload protection.
• The relay provides GPS clock synchronization, including
• Tripping circuit supervision.
message, second pulse and IRIG-B synchronization.
• Remote control and measurements.
• The HMI interface with a LCD and a 9-button keypad on the
• CT failure detection logic.
front panel is friendly to users.
• VT failure detection logic.
• The format of event report is compatible with international
• Voltage and current drift auto regulation.
COMTRADE file.
• Self diagnostic.
• The relay can be integrated in SAS or RTU. The relay is
• GPS clock synchronization.
equipped with Ethernet ports with the IEC 61850 protocol
• Fault Recorder. and RS-485 ports with IEC 60870-5-103 protocol.

Read more on the web


260 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs:
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


www.nrelect.com read more on www.nrelect.com 261
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz

Read more on the web


262 read more on www.nrelect.com www.nrelect.com
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 263
RCS-9626
Motor Management Relay

The RCS-9626 relay provides protection and management


of large/medium motors in solidly grounded, impedance
grounded, Peterson coil grounded and ungrounded systems.
It is suitable to be flush mounted into a control panel.

Management
• Circuit breaker status monitoring
• Remote control and measurements
• Tripping circuit supervision
• Three-phase current and zero-sequence current metering
• Motor startup current monitoring
• Thermal capacity monitoring
• Multiple setting groups
• 64 Trip records
• 64 Operating alarm records
• 64 User operating records
• 8 Disturbance records FR
• 256 SOE records, latest records of following elements
state changing: operating abnormality alarm elements, self-
check alarm elements, protection elements and binary input
Functions elements.
• Circuit breaker operating time monitoring
Protection and control
• Time overcurrent protection (50P/51P) Auxiliary Testing
• Ground overcurrent protection (50G/51G) • Virtual SOE records generation
• Zero sequence overcurrent protection (50N/51N) • Virtual measurement values generation
• Starts per hour, time between starts (66) • Virtual tripping reports generation
• Negative sequence overcurrent protection (46) • Virtual fault wave records generation
• Thermal overload protection (49)
• Residual overcurrent protection (51G)
• Under voltage protection (27) Features
• Mechanical protection (MR) • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Locked rotor protection measurement, calculation and logic discrimination can be
• Voltage and current drift auto adjustment finished within one sampling period. The event recording and
protection logic calculation can be finished simultaneously.
• Self diagnostic
• Voltage transformer supervision (VTS) • The RCS-9626 relay constantly measures and calculates a
large amount of analog quantities, such as phase voltage,
• Current transformer supervision (CTS)
phase-to-phase voltage, phase current, neutral current,
• Rear communication ports: printer active power, reactive power, power factor and frequency.
• Rear communication ports: RS-485/Ethernet
• The relay can monitor and record the operating time of
• Time synchronization port opening/closing circuit breakers.

Read more on the web


264 read more on www.nrelect.com www.nrelect.com
• Multiple GPS clock synchronization, including message, pulse • Strong function optional module can satisfy all kinds of
per second, and IRIG-B synchronization. requirement on site.

• The relay is equipped with one EIA RS-485 standardized • Perfect fault and disturbance record function: 64 latest fault
interfaces and two Ethernet interfaces. Two alternative reports, 8 latest fault wave (up to 15s), 64 user operating
designs of Ethernet interfaces are provided: electrical or records of users to equipment, and 256 records of time tagged
optical. sequence of event can be recorded.

• It can communicate with SAS or RTU using IEC60870-5-103


and MODBUS communication protocols.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6, 1988
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 220VDC 125VDC 250VDC
Pickup voltage 77VDC 154VDC 87.5VDC 175VDC
Dropout voltage 60.5VDC 121VDC 68.8VDC 137.5VDC
Maximum permitted voltage 150V 300V 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000Vac rms for 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
Dropout time(Typical/Max) 8ms/10ms 4ms/10ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Read more on the web


www.nrelect.com read more on www.nrelect.com 265
DC Output
Output range 4 ~ 20mA
Max load resistance 500ohm
Max output voltage 10V

Atmospheric Environment
Standard IEC60255-6:1988
Operating temperature range -25 °C ~ +55 °C
Transport and storage temperature range -40 °C ~ +70 °C
Permissible humidity 5% ~ 95%, condensation not permissible

Mechanical Specifications
Enclosure dimensions (W×H×D) 142.4×266.0×203.0 (unit: mm)
Trepanning dimensions (W×H) 154×268.0 (unit: mm), M5 screw
Mounting Way Flush mounted
Local control panel Small control module: 3 LED indicators, a 9-key keypad and a 160×80-dot LCD
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Ethernet
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Optical Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Fiber Type Multi-mode
Wavelength 1300nm
Ethernet Optical
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


266 read more on www.nrelect.com www.nrelect.com
Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2007 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz /450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2008 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m for 1 minute
1000A/m for 3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:1974, 16 hours at +55°C
Dry cold test IEC60068-2-1:1990, 16 hours at -25°C
IEC60068-2-30:1980, two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 267
RCS-9627
Motor Management Relay

The RCS-9627 relay is used for the protection and


management of large/medium motors in solidly grounded,
impedance grounded, Peterson coil grounded and
ungrounded system. It can be flush mounted into a control
panel.

Management
• Circuit breaker status monitoring.
• Remote control and measurements.
• Tripping circuit supervision.
• Multiple setting groups.
• 64 Trip records.
• 64 Operating alarm records.
• 4 Self-check alarm records.
• 64 User operating records.
• 8 Disturbance records FR.
• 256 SOE records, latest records of following elements
state changing: operating abnormality alarm elements, self-
check alarm elements, protection elements and binary input
elements.
• Circuit breaker operating time monitoring.

Functions Auxiliary Testing


• Virtual SOE records generation.
Protection and control
• Virtual measurement values generation.
• Current differential protection, including magnetic balance
differential protection. (87) • Virtual tripping reports generation.
• Definite time overcurrent protection. (51P) • Virtual fault wave records generation.
• Directional overcurrent protection. (67P)
• Starts per hour, time between starts. (66)
• Negative sequence overcurrent protection. (46) Features
• Thermal overload protection. (49) • O n t h e p r e m i s e o f 2 4 s a m p l e s p e r c y c l e , a l l d a t a
• Residual overcurrent protection. (51G) measurement, calculation and logic discrimination can be
finished within one sampling period. The event recording and
• Under voltage protection. (27)
protection logic calculation can be finished simultaneously.
• Mechanical protection. (MR)
• This relay constantly measures and calculates a large
• Voltage and current drift auto adjustment.
amount of analog quantities, such as phase voltage, phase-
• Self diagnostic. to-phase voltage, phase current, neutral current, active
• Bus and feeder voltage transformer supervision. (VTS) power, reactive power, power factor and frequency.
• Current transformer supervision. (CTS) • The relay can monitor and record the operating times of
• Rear communication ports: printer opening/closing circuit breakers.
• Rear communication ports: RS-485/Ethernet • Multiple GPS clock synchronization, including message,
• Time synchronization port. pulse per second, and IRIG-B synchronization.

Read more on the web


268 read more on www.nrelect.com www.nrelect.com
• The relay is equipped with two EIA RS-485 standardized • Strong function optional module can satisfy all kinds of
interfaces and two Ethernet interfaces. Two alternative requirement on site.
designs of Ethernet interfaces are provided: electrical or
• Fault and disturbance record function: 64 latest fault reports,
optical.
8 latest fault wave (up to 15s), 64 user operating records
• It can communicate with SAS or RTU using IEC60870-5-103 of users to equipment, and 256 records of time tagged
communication protocol. sequence of event can be recorded.

Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Voltage Inputs
Standard Per IEC 60255-6, 1988
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
continuously 120 V 120 V 200V
Thermal withstand capability 10s 200 V 200 V 350V
1s 250 V 250 V 400V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 220VDC 125VDC 250VDC
Pickup voltage 77VDC 154VDC 87.5VDC 175VDC
Dropout voltage 60.5VDC 121VDC 68.8VDC 137.5VDC
Maximum permitted voltage 150V 300V 150V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000Vac rms for 1min
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
Dropout time(Typical/Max) 8ms/10ms 4ms/10ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

DC Output
Output range 4 ~ 20mA
Max load resistance 500ohm

Read more on the web


www.nrelect.com read more on www.nrelect.com 269
Max output voltage 10V
Atmospheric Environment
Standard IEC60255-6:1988
Operating temperature range -25 °C ~ +55 °C
Transport and storage temperature range -40 °C ~ +70 °C
Permissible humidity 5% ~ 95%, condensation not permissible

Mechanical Specifications
Enclosure dimensions (W×H×D) 142.4×266.0×203.0 (unit: mm)
Trepanning dimensions (W×H) 154×268.0 (unit: mm), M5 screw
Mounting Way Flush mounted
Local control panel Small control module: 3 LED indicators, a 9-key keypad and a 160×80-dot LCD
Housing material Aluminum
Housing color Silver grey
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces for communicating with a printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type Test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV

Read more on the web


270 read more on www.nrelect.com www.nrelect.com
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2007 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz /450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2008 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m for 1 minute
1000A/m for 3 seconds
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3 seconds
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:1974, 16 hours at +55°C
Dry cold test IEC60068-2-1:1990, 16 hours at -25°C
IEC60068-2-30:1980, two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 271
Capacitor Protection
Capacitor Protection Applications
How our Capacitor Protection products provide reliable, fast and accurate protection through our patented techniques are described in this
section. Technical data of different devices are provided in each relaying description.

Function Index

Function Functional Code RCS-9631

Phase overcurrent protection 50P/51P √


Overvoltage protection 59 √
Voltage unbalance protection 60V √
Current unbalance protection 60C √
Ground detector protection 64 √
Mechanical protection MR √
Thermal overload protection 49 √
VT failure supervision VTS √
Circuit breaker monitoring √
GPS clock synchronization √
Remote/Local control √
Analog quantity measurements √
Pulse accumulating inputs √
Fault Recorder FR √
IEC60870-5-103 protocol √
IEC61850-8-1 MMS √

Read more on the web


272 read more on www.nrelect.com www.nrelect.com
RCS-9631
Capacitor Management Relay

The RCS-9631 provides protection, control and monitoring


for shunt capacitor banks with single wye, double wye or
delta connection in solidly grounded, impedance grounded,
Peterson coil grounded and ungrounded system. It is fully
compatible with IEC 61850 communication.

• 64 tripping reports and 256 SOE (Sequence of Events)


records.
• Rear communication ports: Ethernet with IEC 61850 or 2
RS-485 with IEC 60870-5-103 protocol, 1 RS-485 for clock
synchronization, 1 RS-485 for communication to printer.

Features
• The RCS-9631 integrates protection, control, monitoring and
metering functions for the capacitor in one rack.

• Definite time and inverse time characteristics of overcurrent


protection are both provided.

• The RCS-9631 relay constantly measures a large amount of


Functions analog quantities, such as phase voltage, phase-to-phase
voltage, phase current, active power, reactive power, power
• Instantaneous overcurrent protection. (50P) factor and frequency.
• Instantaneous zero sequence overcurrent protection. (50N)
• The relay can monitor the status and record the number of
• Time overcurrent protection. (51P) switching times of the circuit breaker.
• Time zero sequence overcurrent protection. (51N)
• The connector type can be selected as plug in/out terminal
• Overvoltage protection. (59) connector or screw terminal connector. The unique plug
• Undervoltage protection. (27) in/out terminal connectors from the relay rear panel to
• Unbalance voltage protection. (60V) the terminal blocks on the rack or cabinet makes the on-
site commissioning and replacement much easier than the
• Unbalance current protection. (60C)
traditional screw terminals when you do the commissioning.
• Earth fault detection. (64)
• On the premise of 24 samples per cycle, all data
• Mechanical protection. (MR)
measurement, calculation and logic discrimination can
• RMS overload protection. (49) be completed within one sampling period. The event
• Voltage and current drift auto adjustment. recording and protection logic calculation are completed
• Voltage transformer supervision. simultaneously.

• Current transformer supervision. • The relay provides GPS clock synchronization, including
• Circuit breaker status monitoring. second pulse, minute pulse and IRIG-B synchronization.

• Circuit breaker control. • The relay is compatible with multiple protocols- IEC61850
• GPS clock synchronization. and IEC 60870-5-103. It provides networking interface such
as RS485, RS232 and Ethernet port.
• Fault Recorder.

Read more on the web


www.nrelect.com read more on www.nrelect.com 273
Technical data
Power Supply
Rated Voltage (Un) 24Vdc, 30 Vdc, 48Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 15 W
Burden
Operating condition < 25 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs:
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V 200 V
linear to 100 V 173 V 230 V
continuously 120 V 120 V 200 V
Thermal withstand capability 10s 200 V 200 V 350 V
1s 250 V 250 V 400 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 77VDC 87.5VDC 154VDC 175VDC
Dropout voltage 60.5VDC 68.8VDC 121VDC 137.5VDC
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 4ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimension (W×H×D) 142.4×266.0×203 (unit: mm)
Trepanning dimension (W×H) 154.0×268.0, M5 screw
Mounting Flush mounted

Read more on the web


274 read more on www.nrelect.com www.nrelect.com
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces connecting with RTU/SCADA
Port number 2
Baud rate 4800 ~ 38400bps
Transmission distance < 1000m@4800bps
RS-485 (EIA)
Maximal capacity 32
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2~3
Connector type RJ-45
Transmission Rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2~3
Ethernet
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Optical Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 1500m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Interfaces connecting with printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
RS-485 (EIA) Transmission distance < 500m
Maximal capacity 32
Timing standard PPS, IRIG-B
RS-485 (EIA)
Safety level Isolation to ELV level

Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns

Read more on the web


www.nrelect.com read more on www.nrelect.com 275
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

276 read more on www.nrelect.com


PCS-9656
Arc Protection System

The PCS-9656 arc protection system is used to prevent


short circuit by arc light for circuit breakers in medium &
low voltage busbar and switch cabinet applications. The
integrated unique sensor technology can help to fast locate
arc short circuit and the device can quickly trip the fault circuit
to minimize harms caused by arc light. The PCS-9656 can be
installed in a control panel or in a switch cabinet.

unit). It fully supports IEC61850 and GOOSE functions can


be used in smart substations and smart power plants.

• Multi time synchronization modes are supported, including


IRIG-B and SNTP.

• Various communication modes are supported: up to four


100Mbps Ethernet ports and two RS-485 serial ports,
supporting IEC61850, IEC60870-103, and DNP3.0.

• Convenient site device testing functions are provided,


including binary output test and output driving test.

• Event recording function is provided: 64 latest fault reports,


1024 latest self-check reports, 1024 latest remote control
• The current and arc dual criteria are adopted to enhance reports, 1024 latest user operation reports, and 1024 latest
protection reliability. The current criterion is based on the SOE event reports.
patented Deviation of Power Frequency Component(DPFC)
• Fault recording function to record the 64 latest fault data.
principle.

• Passive arc probe with strong anti- interference capability is


adopted to transmit analog optical signal.

• The realtime background light adjustment function is adapt


System compositions
to occasions with different background light requirements.
PCS-9656 Arc Protection Unit
• Accurate fault locate function: the fault position can be The arc fault protection system is composed of one or several
directly displayed on the device. The local SOE records PCS-9656 arc protection units. The device adopts flexible
are uploaded to automation system to facilitate fast fault modular design that function modular can be configured or
clearance and power supply restore. extended according to the actual engineering demands.
• S t r o n g e x p a n d a b i l i t y a n d a d a p t a b i l i t y : v i s u a l i z e d
programming technology is used. The arc protection system The PCS-9656 arc protection unit can collect electric signals
allows users to modify settings according to site conditions and arc signals locally, or receive electric signals from other
such as different wiring configurations nd operation modes. merging units and arc signals from other slave units, to perform
functions such as logic discrimination, tripping output, event
• The tripping outputs adopt the combination of IGBT recording, and man-machine interaction etc.
and relays. The output operation time is less than 1ms.
Conventional relay outputs can be used separately. The
PCS-9656SH Arc Sensor
tripping outputs provide tripping matrix configuration to
The arc sensor is used to transmit the detected analog optical
satisfy different applications.
signals to arc fault protection units for optic-electric signal
• The arc protection system integrates circuit breaker failure conversion, thus to avoid EM interference during signal
protection function. Up to 6 circuit breakers can be protected. transmission.

• The arc protection system can receive sampled values from


both traditional CT/VT and electronic CT/VT(via merging

read more on www.nrelect.com 277


Technical data
Power supply 110VDC/220VDC
<15W (Quiescent condition)
Burden
<20W (Quiescent condition)
24 optical signal inputs; 6 data transmission ports
21 BI, 110VDC/220VDC
AC Inputs 12 current inputs, 1A/5A optional, < 0.2VA/phase, @In
Thermal withstand capability: 3In continuously
30In for 10s
100In for 1s
11 conventional output; 6 fast output;
1 normally closed device blocking signal contact;
Outputs
1 normally open device alarm signal contact;
Rated voltage: 250Vac/dc; making current: 5A
Operation time <10ms (optical and electric dual criteria; including relay operation time)
Working temperature -40°C ~ +70°C
Mechanical dimensions 247×177×234 (unit: mm) (W x H x D)
Relative humidity 5% ~ 95%, neither dewing nor icing inside equipment
Atmospheric pressure 70kPa ~ 106kPa

278 read more on www.nrelect.com


SMART SUBSTATION SOLUTION

PCS-221
Merging Unit

Merging units are used to sample AC analog values and


transmit the sampled values(SV) to protection devices,
bay control units(BCU) or electric meters through optical
communication channels based on the IEC61850-9-2
Functions protocol or IEC60044-8 protocol.

• IEC61850-9-2 sampled value transmission


• IEC60044-8 sampled value transmission
• GOOSE transmission/reception the GPS signal and thus has higher reliability. In practice, the
• GMRP function mentioned two methods can be used in combination to achieve
• Voltage and current synchronization better accuracy.
• IEC60044-8 voltage sampled value reception from a busbar
MU
• Voltage transfer Connection to protection & control devices
• Data synchronization
Merging units and protection & control devices are usually
connected through optical fibers based on IEC61850-9-1/2
or IEC60044-8 protocol. When using IEC60044-8 protocol,
Data synchronization the merging unit only supports point-to-point communication
with speed of 2.5Mbit/s or 10Mbit/s; when the IEC61850-9-
Input sampling signals, such as three-phase current and
1/2 protocol is adopted, it is compatible with both Ethernet
voltage, need to be synchronized if the merging unit is
communication and point-to-point communication. The point-
connected to several electronic CTs/VTs and electro-magnetic
to-point communication is usually applied to the protection and
CTs/VTs. This can be solved either by GPS PPS, or by angle
control devices which have high requirements on real-time data
adjustment interpolation. The GPS PPS signal can gradually
sampling. The Ethernet network communication can be applied
adjust the sampling interval of all intelligent sampling modules
to bay control units and metering devices which have less
through the merging unit to realize synchronous sampling
requirements on real-time data sampling. In the point-to-point
automatically. However, the synchronization accuracy of this
communication, it is much easier to use Manchester code than
method relies on the integrality and the accuracy of GPS PPS.
Ethernet technology. Thus, it is recommended to use IEC60044-
Any loss of GPS PPS may directly influence the synchronization
8 protocol to realize the communication between merging units
accuracy. The other way to synchronize the data sampling is
and bay level devices in the practical application.
using angle adjustment interpolation which does not rely on

Technical data
Power Supply
Standard IEC 60255-11:2008
Rated Voltage (Un) 110V/125V, 220V/250V
Voltage Range 80%Un~120%Un
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
Quiescent condition <25W
Burden
Operating condition <30W

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz

read more on www.nrelect.com 279


Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
Thermal withstand capability
for 10s 30In
for 1s 100In
Thermal withstand capability
for half a cycle 250In
Burden <0.15VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 55% rated voltage
Maximum permissive voltage 120% rated voltage
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Signal contact
Output mode Potential-free contact
8A@380V AC
Continuous carry
8A@250V DC
Pickup time <10ms
Drop-off time <8ms
10A for 3000ms
Short duration current
20A for 500ms
0.6A @ 48Vdc , L/R=40ms
Breaking capacity (L/R=40ms) 0.3A @ 110Vdc, L/R=40ms
0.2A @ 220Vdc, L/R=40ms
380V AC
Maximal working voltage
250V DC
Test voltage across open contact 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 225.00mm× 177.00 ×268.80mm
Mounting Flush mounted
Trepanning dimensions (W×H) 226.00mm×178.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Read more on the web


280 read more on www.nrelect.com www.nrelect.com
Communication Port
- Sampled Value Transmission Channel
Characteristic Glass optical fiber
Connector typel LC
Optical Ethernet
Transmission standard 100Base-FX
Fibre type Multi mode
Transmission distance <2km
Wave length 1310nm
Protocol IEC61850-9-2 or IEC60044-8
Optical Ethernet
Transmission power Min. -20.0dBm
Minimum receiving power Min. -30.0dBm
Margin Min +3.0dB

- Time Synchronization Interface


Medium Parameters
Port number 1
Optical RS-485 Connector type ST
(EIA) Transmission distance < 2000m
Timing standard PPS, IRIG-B
Port number 1~2
Connector type LC
Optical Ethernet
Transmission distance < 2000m
Timing standard IEEE1588

Type test
- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

Read more on the web


www.nrelect.com read more on www.nrelect.com 281
PCS-222
Circuit Breaker Controller

The PCS-222 is an intelligent terminal used to control


primary switching device (including circuit breaker and
main transformer) in smart substation of all voltage levels. It
Functions supports realtime GOOSE communication, and can realize
tripping and closing of circuit breakers and switches by
• Tripping and closing of circuit breakers matching protection and BCU. It can locally acquire binary
This device receives various GOOSE signals from protection signals of primary equipment such as breakers and switches
device, including tripping signals (initiating AR), tripping signals at the same time. It can meet the requirement of GOOSE
(not initiating AR), and reclosing signals, and then drives tripping by point-to-point mode.
corresponding output relays to convert GOOSE signals to
output. The device can be installed outdoor nearby the primary
equipment or connected to the protection & control devices
• Remote control outputs in the control room via optic GOOSE network. Special
cabinets are designed for Circuit Breaker Controllers to fulfill
This device provides 33 binary output. In addition to tripping/
the requirements of dust-proof, humidity-proof, and radiation
closing and blocking outputs of circuit breaker, it also has
protection.
remote control tripping, closing and blocking contacts for four
disconnectors and four earth switched, which are 24 output
contacts in total.

• Remote signal inputs


This device provides 54 binary inputs. It can locally acquire
binary quantities such as breaker position, switch position, and
signals of circuit breaker mechanism and main transformer
body, and upload them to corresponding protection device or
BCU via GOOSE network.

Features
• All plug-in modules in this device can be smoothly upgraded
to keep compatible with UAPC platform, thereby provides a
solid protection on users' investment in equipment for a long
period.

• The device adopts high-performance DSP, internal high-


speed bus, and intelligent I/O. Both hardware and software
adopt modular design, allowing flexible configuration, general
module for both plug-in module and software modules,
and easy expansion and maintenance. Numbers and Figure 1. Outdoor Cabinet
types of spare plug-in modules that user needs to keet for
replacement are largely reduced.
consumption and heat dissipation is reduced, which improves
• This device can receive GOOSE signals such as protection the security of the device.
tripping/closing, manual closing/tripping of BCU and control
of disconnecters and earth switch, and output corresponding • The device provides flexible communication modes. It is
contacts. It can acquire and upload positions of breakers/ equiped with 15 independent GOOSE interfaces and 1 RS-
232 commissioning port, and it supports new generation
disconnecters/earth switch, and breaker body signals etc.
substation communication standard IEC61850.
• Time between receiving GOOSE message and correspoding
• Supporting IRIG-B synchronization via fiber optical interface
at output relay is less than 7ms, and this is normally not and IEEE1588 time synchronization and 256 latest local
affacted by GOOSE network storm. operation records.
• This device adopts fully enclosed relays which has high • The funcion of measurement of ambient temperature and
impedance and low power consumption, thus its power humidity is integrated.

Read more on the web


282 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Standard IEC 60255-11:2008
Rated Voltage (Un) 110V/125V, 220V/250V
Voltage Range 80%Un~120%Un
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
Quiescent condition <35W
Burden
Operating condition <50W

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropoff voltage <55% of rated voltage
Maximum permissive voltage 120% of rated voltage
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Output mode Potential free contact
8A@380V AC
Continuous carry
8A@250V DC
Pickup time <10ms
Drop-off time <8ms
10A@3s
Short duration current
[email protected]
0.7A@48Vdc
Breaking capacity (L/R=40ms) 0.3A@110Vdc
0.2A@220Vdc
380V AC
Maximal working voltage
250V DC
Test voltage across open contact 1200V RMS for 1minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- For Process Level
Characteristic Glass optical fiber
Connector typel LC
Fibre type Multi mode
Transmission distance <2km
Wave length 1310nm
Transmission power Min. -20.0dBm
Minimum receiving power Min. -30.0dBm
Margin Min +3.0dB

Read more on the web


www.nrelect.com read more on www.nrelect.com 283
- For Synchronization Port
Characteristic Glass optical fiber
Connector typel ST
Fibre type Multi mode
Wave length 820nm
Minimum receiving power Min. -25.0dBm
Margin Min +3.0dB

- For Debug Port


Type RS-232
Baud rate 9600bps
Safety level Isolation to ELV level

Read more on the web


284 read more on www.nrelect.com www.nrelect.com
PCS-223
CB Online Monitoring Unit

The PCS-223 circuit breaker(CB) online monitoring unit


provides the online monitoring of circuit breaker and switches
in smart substations of all voltage levels. It can locally collect
the operation signals of circuit breakers and switches and
send the data to substation automation system. The device
supports IEC61850-9-1 MMS and GOOSE.
Functions
• Acquisition and supervision of SF6 pressure
This device acquires SF6 pressure via sensor and issue an
alarm if it exceeds the threshold.

• Acquisition and supervision of SF6 temperature Features


This device acquires SF6 temperature via sensor and issue
an alarm if it exceeds the threshold. • PCS-223A is a new generation intelligent online device that
fully supports digital substation. This device adopts latest
• Acquisition and supervision of SF6 moisture UAPC platform developed by NR and supports GOOSE and
This device acquires SF6 moisture via sensor and issue an MMS communication.
alarm if it exceeds the threshold. • UAPC platform is designed for service life up to 10-15 years.
Device cards can be smoothly upgraded as required and
• Acquisition of circuit breaker energy charging consistent with the platform, so as to provide long-term stable
This PCS-223 provides the realtime monitoring of circuit guarantee of user equipment investment.
breaker energy charging motor current. If an abnormal
operation current is detected, the device will issue an alarm, • The device adopts high performance DSP, high-speed
and trip the motor operating circuit selectively. internal bus, modular design of hardware and software, and
flexible configuration. It features general purpose cards and
• Acquisition of motor current for isolator software modules, easy expansion, easy maintenance, fewer
This PCS-223 provides the realtime monitoring of motor types of spares, and easy replacement.
current for isolator. If an abnormal operation current is • The device adopts fully sealed, high impedance, low power
detected, the device will issue an alarm, and trip the motor consumption imported relays, to reduce device power
operating circuit selectively. consumption and heat generation, and improve device safety.

• Monitoring of circuit breaker operation characteristics • Flexible communication mode is provided with 2 independent
The device acquires the operation curve of circuit breaker optical Ethernet interfaces and 1 RS-232 debugging port.
via offset sensor to detect the potential problem of circuit New generation substation communication standard
breaker, and to issue an alarm. IEC61850 is supported.

• Fiber optical IRIG-B code timing is supported and 1 fiber


• Mechanical service life of circuit breaker optical IRIG-B time code input interface is provided (also
The device can count the numbers of circuit breaker supporting PPS).
operations.
• Latest local 256 operation reports can be recorded.
• Electrical service life of circuit breaker • This device adopts integrated and fully enclosed chassis,
The PCS-223 can estimate the remaining electrical service so that resistance to interference reaches highest grade of
life of circuit breaker through the monitoring of primary various EMC standards.
current.
• This device has passed severe high temperature test, low
temperature test, and EMC test, and can operate in severe
outdoor environment.

Read more on the web


www.nrelect.com read more on www.nrelect.com 285
PCS-9250 EGI/EAI
Electronic CT/VT

To keep pace with the increasing demands of transmission


capacity and rising system voltage, NR has pursued
advanced research on electronic CTs and VTs to ensure
maximum reliability, and availability in the applications of
metering and protection relays. ECTs/EVTs have advantages
of none magnetic saturation, none ferromagnetic resonance,
large dynamic measuring scope, wide frequency band and
compact structure.

NR’s electronic CTs/VTs are suitable for both gas-insulated Remote end module: The electronic CT/VT for GIS is
switchgears air-insulated switchgears and have been proven composed of two duplicated remote end modules which are
in the laboratory and are successfully put in-service in real used to receive and process output signals for low power CT,
substation applications worldwide. air core coil and capacitor voltage divider. The output signals
of remote end module are transmitted to merging units through
optical fibers. Primary sensors and remote end modules are all
Active Current Transformer installed at low voltage side with duplicated configuration.

- Electronic CT/VT in GIS Application - Electronic CT/VT in AIS Application


The electronic CT/VT for GIS can be applied to 110kV (220kV, Electronic CTs/VTs in AIS application can be applied to 110kV
330kV or 500kV) gas insulation switch(GIS) for measuring (220kV, 330kV or 500kV) substations for primary current and
primary current and voltage. The output signal will be sent to voltage measurement. The output signals are sent to digital
digitizing measuring devices, bay control units and protective measurement devices, bay control units and protective relays. It
relays. It can be installed both indoor and outdoor. can be installed both indoor and outdoor.

Electronic CTs/VTs in GIS application are composed of following


three parts:

Main Body: The main body includes transformer tank, adapter


flange, insulation salver, primary conductor, built-in current and
voltage sensor. The space between primary conductor and
transformer tank is filled with SF6 insulating gas.

Primary Sensor: The primary sensor is composed of two


duplicated sensors, each of which includes one low power
CT(LPCT), one air core coil and one coaxial capacitor voltage
divider.

Figure 2. ECT/EVT for AIS Application

• ECT in AIS application


ECTs in AIS applications are composed of four parts:

Primary sensor: The primary sensor is composed of one


low power CT, two air core coils and one HV current energy
acquisition coil. It is installed at high voltage side.

Dual remote electronic modules:


The dual remote electronic module is located at high voltage
side. It receives and processes output signals for low power
CT and air core coil. The output of remote electronic module is
Figure 1. Electronic CT/VT for GIS Application series digital optic signal.

286 read more on www.nrelect.com


Optic insulator: The optic insulator is composed of solid prop
composite insulator with eight built-in multimode optical fibers,
of which four are used to transmit laser and digital signals, the
other four are standby optic fibers.

Merging unit: Merging units are placed in the control room to


provide laser power supply and receive three-phase current
and voltage signals. The output of merging unit will be sent to
protection and control devices using IEC60044-8 or IEC61850-
9-1/2 protocol. Figure 3. DC Electric CT/VT
• Electronic CT/VT Group in AIS Application
Electronic CT/VT groups are integrations of ECTs and EVTs Optic insulator: The optic insulator is composed of solid
which are used in AIS application. It is composed of four parts: suspended composite insulator with eight built-in multimode
optical fibers, of which three six are use to transmit laser and
Primary current sensor: Primary current sensors are placed digital signals, the other two are standby optic fibers.
at HV side. It includes one low power CT, two air core coils and
one HV current draw-out coil. Merging unit: Merging units are placed in the control room to
provide laser power supply and receive three-phase current
Dual remote electronic modules: Dual remote electronic and voltage signals. The output of merging units will be sent to
modules are located at high voltage side. It receives and protection and control devices using IEC60044-8 or IEC61850-
processes the output signal of low power CT and air core coil. 9-1/2 protocol. Merging units are connected to remote modules
The output of remote electronic module is series digital optic via optic fibers.
signal.

Capacitor voltage divider: The capacitor voltage divider - Medium and Low Voltage Electronic CT/VT
can divide high voltage into low voltage signal and send it Medium and low voltage electronic CTs/VTs are installed in
to remote modules for processing. It also can be used as an 10kV-35kV switchgear cabinets or outdoor to measure primary
communication carrier device. current and voltage. The output signals are delivered to digital
measurement devices, bay control units and protective relays. It
Merging unit: Merging units are placed in control rooms to
is composed of low power CTs (LPCTs), transport modules and
provide laser power supply and receive three-phase current
remote onsite acquisition units etc.
and voltage signals. The output of merging units will be sent to
protection and control devices using IEC60044-8 or IEC61850-
9-1/2 protocol.

- DC Electronic CT
DC electronic CTs are intended for applications in HVDC
converter station. It measures DC current and harmonic current,
and output digital signals to protection and control devices in
converter station. The DC electronic CT is composed of four
parts:

Primary sensor: The primary sensor includes one current


divider and one air core coil. The current divider is used to
measure DC current and the air core coil is used to measure
harmonic current.

Remote modules: DC electronic CTs have three remote end


modules which can backup each other to guarantee high
Figure 4. Medium and Low Voltage Electric CT/VT
reliability. The remote module receives and processes output
signals of current divider and air core coil. The output of remote
module are serial digital optical signal.

Technical data
- Electronic CT/VT for GIS Application
Max. operation voltage Um(kV) 126 252 363 550
Withstand voltage (kV) 230 460 510 680
Lightening impulse withstand voltage(kV) 550 950/1050 1175 1550
Switching impulse withstand voltage(kV) - - 950 1175
Rated primary voltage(kV) 110/ √3 220/√3 330/√3 500/√3
Rated primary current(A) 300~3000 300~3000 300~3000 300~3000
Short time thermal current, 3S (kA), 3s 40 50 50 63

read more on www.nrelect.com 287


Dynamic stability current(kA) 100 125 125 158
Accurate limit coefficient 20, 25, 30, 40
Environment temperature -40°C ~ +50°C
Type Digital
Port Current Measurement Current protection Voltage measurement Voltage protection
Secondary output
Rating 2D41H 01CFH 2D41H 2D41H
Accuracy 0.2s 5TPE 0.2 3P

- Electronic CT/VT for AIS Application


Max. operation voltage Um(kV) 126 252 363 550
Withstand voltage (kV) 230 460 510 680
Lightening impulse withstand voltage(kV) 550 950/1050 1175 1550
Switching impulse withstand voltage(kV) - - 950 1175
Rated primary voltage(kV) 110/√3 220/√3 330/√3 500/√3
Rated primary current(A) 300~3000 300~3000 300~3000 300~3000
Short time thermal current, 3S (kA), 3s 40 50 50 63
Dynamic stability current(kA) 100 125 125 158
Accurate limit coefficient 20, 25, 30, 40
Ambient temperature -40°C ~ +50°C
Type Digital
Port Current Measurement Current protection Voltage measurement Voltage protection
Secondary output
Rating 2D41H 01CFH 2D41H 2D41H
Accuracy 0.2s 5TPE 0.2 3P

- Electronic CT/VT for AIS Application


Rated operation voltage Um(kV) 500kVDC
Max. operation voltage (kV) 515kVDC
Lightening impulse withstand voltage(kV) ±1425kVcrest
Switching impulse withstand voltage(kV) ±1300kVcrest
DC withstand voltage(kV) ±1425kVcrest
Rated primary current Ipr 1000~3000ADC
Rated Short time thermal current Ith 8kArms, 1s
Dynamic stability current Idyn 20kAcrest
Max. continuous overcurrent 1.2Ipr
8 hours overload current 1.3Ipr
Radio interference voltage(RIV) The RIV is less than 1000uV when the measured voltage is 635kVDC
Max. temperature The max. temperature in the CT/VT is no larger than 65K at rated primary current
Max. measured current 6Ipr
Sample rate 32kHz
Data rate of output signal 10kHz
Protocol TDM/IEC60044-8(optional)
Transmission Medium 62.5/125μm multimode fiber

- Electronic CT/VT for GIS Application


Max. operation voltage Um(kV) 10 35
Withstand voltage (kV) 42 95
Lightening impulse withstand voltage(kV) 75 185/200
Switching impulse withstand voltage(kV) - -
Rated primary voltage(kV) 10/ 35/√3
Rated primary current(A) 50~3000 50~3000
Short time thermal current, 4S (kA), 3s 31.5 31.5
Dynamic stability current(kA) 80 80
Accurate limit coefficient 20, 25
Ambient temperature -15°C ~ +40°C
Type Digital
Port Current measurement Current protection Voltage measurement/protection
Secondary output
Rating 4V/2D41H 225mV/01CFH 4V/6.5V/2D41H
Accuracy 0.2s 5P 0.2/3P

Read more on the web


288 read more on www.nrelect.com www.nrelect.com
PCS-9250-OAI
Fiber Optical CT

PCS-9250-OAI Fiber Optic CT(FOCT) is a passive optical


current transducer which uses light to accurately measure
current on high voltage systems. The sensor at high voltage
side of passive optical CT is composed of insulation materials
such as optical fiber and glass etc.

FOCT is designed based on Faraday magneto-optical effect


and adopts special optical fibers as current sensing medium.
Connections between components rely on optical fiber
communication which has advantages of strong anti-vibration
capacity and long-term reliability and stability.

Features
• Signals are transmitted via optic fibers at HV side without any • FOCTs are composed of three parts:
electrical circuit. High insulation property of optical fiber can - Fiber optic transmission system: FOCT uses fiber optic
guarantee the complete electrical separation to prevent the transmission system to connect HV side and LV side. It
risk of open circuit on LV side. delivers optic signals from source to primary current sensor
• No magnetic saturation and ferromagnetic resonance. and transmits feedback signals to modulator circuit.

• Wide dynamic measuring range and high measuring - Signal modulating device: The signal modulating device
accuracy. includes light source and optic components such as
detector and primary current signal processing system.
• With benefit in wide range of frequency response, FOCTs The circuit processing system of merging unit receives and
can measure high-order harmonic, transient current and DC processes three-phase current signals and output digital
current more accurately. current signals to protective relays.
• FOCT has strong universality to adapt to various current • The complete symmetrical reciprocal optical design can
transformers with different voltage levels and different current greatly reduce the risks of environmental impact to guarantee
rating. higher reliability of optic circuit. The light-weight sensing
• Oil insulation is replaced by simplified insulation structure to ring can be widely applied to the traditional column-type CT,
eliminate flaming and explosion risks. The small volume and bushing-type CT and also can be integrated in GIS.
light weight can help to save the installation space.

• NR’s FOCT adopts Sagnac interference technique to reduce


the impact of ambient temperature and vibration etc.

Figure 1. Structure of FOCT sensing system

Read more on the web


www.nrelect.com read more on www.nrelect.com 289
AUTOMATION
Substation Automation System

PCS-9700
Substation Automation System

PCS-9700 is a state-of-the-art automation solution for


substations, generations and industrials with many advanced
The PCS-9700 helps customers to realize the automation of technologies and patents. It can be applied for substations
local operations and collection, evaluation and forwarding starting from distribution level up to extra high voltage level.
of data, and provides the remote control and monitoring of It integrates the application of protection, control, Ethernet,
power system operation status. It is suitable for the following IT and communication technology based on the international
applications: standard and it is fully compatible with IEC 61850 standard.
The system adopts the layered distributed architecture with
RCS-9700 helps the customers to realize the automation of bay-oriented and object-oriented structure, which is more
local operations and the collection, evaluation and forwarding reliable and easy to extend and maintain.
of data, and provides the remote control and monitoring
functions for power system status. It is suitable for the following
applications:
• Transmission and distribution substations, generation and bus. Compared to traditional substation, the process bus based
industrial electrical system optical fiber is used to replace cable connection between IEDs.
It will significantly reduce the construction work and cost.
• Utilities, power plants and industries
• New constructed substations and retrofit substations Process Bus Solution
• Gas and air isolated switchgear The process bus is one of the focus points to realize smart
• Subway system, light-rail system, and electrified railway substation. The process bus with GOOSE and IEC 61850-9-
system 2 is adopted in NR’s smart substation solution. It realizes the
transmission of sampled values, state information, tripping/
closing commands and interlocking command.
IEC 61850 Compatibility
NR’s substation automation system is fully compatible with IEC NR’s innovative smart substation solution aims at realizing
61850 standard and has passed the IEC 61850 conformance the modern substation operation modes by using a fiber optic
test and obtained the level A certification issued by KEMA. NR network instead of the conventional cable wiring and thereby
sets up its own IEC 61850 level B test laboratory to confirm the reducing the workload and extending the substations operational
standard compliance for all product portfolio. period. NR’s smart substation solutions include process level
equipment such as electronic fiber CT/PT, merging units, circuit
The IEC 61850 standard provides an internationally recognized breaker controller and local control panels. It also includes the
method targeted for interoperability between IED from different PCS series protection and control devices like protective relays,
venders. The IEC 61850 has built-in capability for high-speed disturbance recorders, automation systems, remote control
control and data sharing over the network, eliminating most systems and protection information systems.
dedicated control wirings. It is also easy to follow the future The merging unit is suitable for traditional CT/VT and electronic
communication technology, which should save the long-term CT/VT. It distributes the digitalized data of current/voltage to
upgrade investment for the customer. various IEDs in bay level via process bus or point-to-point
optical fiber.
NR protection relays, bay control units and substation
automation systems are completely compatible with IEC • Electronic CT/VT digitalizes the current/voltage signals and
61850. We also provide solutions that allow the migration from transmit them to various IEDs (protections, control units,
the conventional substation automation system to the new metering and disturbance recorders) via optical fiber.
standard. The PCS series protection and bay control units • Merging Unit gathers digitalized data of current/voltage and
support the IEC 61850-9-2 and GOOSE message for process distribute it to various IEDs via process bus.
bus. The sampled value, interlocking, real-time tripping/closing, • Circuit Breaker Controller collects state information of
interlocking and state information are transported via process breaker, transmit them to various IEDs via process bus,

290 read more on www.nrelect.com


receive the tripping/closing commands via process bus and locally. The information subsystem provides a powerful fault
implement these commands. analysis tool. When fault occurs, the information subsystem
• Local control panel realizes the local installation of can transmit protection operation information and fault report
protection and control devices to dispatching center quickly, helping dispatchers to get correct
fault information, make rapid and correct fault analysis as well
• Gigabit switch guarantees the real-time transmission of
as decision on fault clearance.
information in process bus.

• PLC function based on IEC61131


Programmable control function is designed based on IEC61131
Functions standard. It can complete logic latching of individual device
sequential control, group control as well as station-wide control.
• Real-time data acquisition and processing
The system makes acquisition and processing of real-time data • SAS software package (HMI)
of supervisory and control units installed in bay level. The system provides powerful and friendly human machine
interfaces software package including:
• Control operation, synchronism checking and interlocking
The system can make sequential operations on circuit breakers, - Setup and maintenance of data base
motor-driven isolators, transformer tap changer, reactive - Reactive power and voltage automatic regulation
power device group, etc. PCS-9705 and RCS-970x bay control - Configurable Alarm processing
units carry out control operations, synchronous checking and - Sequence of events record and post-fault review
electrical interlocking functions. Interlocking software is used - Configuration and displaying of graph and chart
mainly for implementation of edition, compilation and download - On-line calculation and reports preparing
of interlocking logic. - Operation management
- Electricity processing
• Communication with control center
- Self-diagnosis and self-restoration
Communication with control center is independent to local
HMI. Control command can be transmitted directly from control
center. It supports IEC standard protocols and other standard
protocols such as DNP3.0 and 1801 as well. Features
• Time synchronization • Optimized design scheme
The system receives GPS standard time signal for clock The PCS-9700 system is considered for various functions of
synchronism. The absolute time are broadcasted through protection, local supervisory, control, reactive power and voltage
network. The second or minute pulse signal is inputted to regulation, interlocking, selective ground fault protection of
equipments by RS-485 port or potential free contact. The IRIG-B an ineffectively grounded system, as well as management of
signal (AC or DC) is also supported. equipments, operations and information of protection and fault
recorder information, etc.
• Interfaces with third-party IEDs
Protocol converters complied with IEC 61850 is provided for the • Powerful and flexible communication facilities
integration of third-party IEDs. It can convert non-IEC 61850 The station bus uses 100M Ethernet while the bay level uses
protocol to IEC 61850 and realize the full automation of all IEDs dual 100M Ethernet as redundancy. A powerful communication
in substation. platform is thus formed by these facilities together with network
communication equipments such as 100Mbps Switches and
• Protection and fault information management. gateways. The process bus uses redundant Gigabit or 100M
The system can acquire protection information, fault Ethernet based on optical fiber. It will guarantee the real-time
information, power system stability control and other automation transmission of important information, such as tripping/closing
equipments, and make display, analysis and processing commands.

The system uses IEC 60870-5-103 standard protocol for


communication with protection relays and other IEDs. The
RCS-9794A/B communication unit of multiple CPU structure
is equipped as protocol converter. It provides various standard
ports and the system can be connected with equipments made
by other manufactures. So the user has the flexibility to select
various kinds of products.

• Open HMI software in substation level


The software of the system is developed based upon Windows
and UNIX operation system. SQL server (companied with
Windows) or ORACLE (companied with UNIX) is selected as
the database management software. Based on softbus and
network technology, Software package is an open system which
greatly enhances the availability of internal information of the
whole station.
Figure 1 Intelligent Control Panel

read more on www.nrelect.com 291


• Direct data transmission to control center • Network level
Functions of external communication and internal The network level supports single or dual network based
communication are independent to each other. Information on distributed or ring structure. Balance flow control is
can be acquired directly from bay level and transmitted to used for duplicated network, so the reliability and the real-
dispatching centers. Communication bottleneck problem of time performance can be ensured. This network level can
the traditional RTU scheme can be solved so that reliability of communicate smoothly with equipments produced by other
information transmission can be greatly enhanced in PCS-9700 manufacturers using IEC standard communication protocol
system. or private communication protocol. Optical links is used as
a transmission medium with sever EMC immunity. Time
• Object-oriented information structure synchronization can be realized by a GPS interface conveniently
The information structure is object-oriented. Each logic devices and correctly.
in database is associated with a physical device. Influence of
single item change is limited in related part of corresponding • Bay level
logic device only. It is thus easy to be extended. The bay level consists of bay control units, various protection,
disturbance recorders and other IEDs. All these IEDs from NR
Attribution of information is self-described. It supports on-line support IEC 61850-8-1 for station bus and redundant Ethernet
configuration and real-time check functions of the equipments. ports. These equipments can operate with long-term stability
in severe environments, for example, high temperature, high
• Secure and reliable bay control unit humidity or high electro-magnetic disturbance.
The bay control unit is based on 32 bits CPU and DSP hardware
platform. It adopts real-time multitasks operation system with • Process Level (Optional)
powerful processing ability and well suits the requirements of The process level consists of process bus and intelligent
data acquisition and processing of bay level. devices including electronic CT/VT, merging unit, icircuit breaker
controller and local control panel. Merging unit can be applied
for traditional CT/VT. It receives the current/voltage via cables,

System Architecture converts them into digital information and distributes them to
various IEDs in bay level. Gigabit switch is supplied for process
bus to realize the real-time information transmission. Process
• System Architecture bus can be configured as redundant Ethernet based on optical
The system comprises three or four levels in hierarchical fiber.
structure: Station Level, Network Level, Bay Level and optional
Process Level. • Typical structure description
• Station level consists of host, operator station and engineer
• Station Level station. Several computers or single computer configuration
The station level is a distributed system comprising a single can be adopted.
computer host or several hosts. It provides supervisory, control
• Windows or UNIX can be used as the operation system.
and management functions for operators in the substation. Man-
machine interface is friendly and easy to handle. The structure • T he gateway can adopt RCS-9698G/H device, channel
makes it flexible to be extended and reliable to be operated. switching equipment and channel interface.
By applying the component technology, “plug-and-play” can
• RCS-9785 can be used as the GPS receiver.
be realized for software functions. It can communicate with
dispatching centers or other concentrated control stations using • PCS and RCS series protection equipments can connect
different standard protocols such as IEC-60870-5-101 and IEC- with station level directly by two 100M Ethernet ports or by
60870-5-104. two RS-485 ports through protocol converter.

Figure 2. Double-Star Ethernet Structure of PCS-9700 Automation Figure 3. Ring Ethernet Structure of PCS-9700 Automation System
System Complied with IEC61850 Complied with IEC61850

Read more on the web


292 read more on www.nrelect.com www.nrelect.com
Technical data
Ratings
AC power supply 380 V/220 V, 50 Hz, 60 Hz
DC power supply 250V/220 V/125V/110 V
Secondary current of TA 5 A/1 A
Secondary voltage of TV 100 V/31/2, 110V/31/2
Pulse input: potential free contact, 40 ms min.
Digital input: potential free contact, DC 250V/220 V/125V/110 V
Digital output: potential free contact, 8 A

Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2, class 4
Radiated, radio-frequency electromagnetic field IEC 61000-4-3, class 3
Electrical fast transient/burst IEC 61000-4-4, class 4
Surge IEC 61000-4-5, class 3
Conducted disturbances, induced by radio-frequency fields IEC 61000-4-6, class 3
Power frequency magnetic field IEC 61000-4-8, class 4
Pulse magnetic field IEC 61000-4-9, class 5
Damped oscillatory magnetic field IEC 61000-4-10, class 5
Oscillatory waves IEC 61000-4-12, class 2
Maximum capacity
Telesignal 65535
Telemetering 65535
Telecounting 65535
Telecontrol 65535
Teleregulation 65535
Total number of stations can be comprised in system of a controlling
65535
station

Accuracy
Resolution of A/D conversion 14 bits
GPS clock synchronism ≤ 1 ms
GPS clock synchronism ≤ 2 ms
Total error of analog quantity measurement
Voltage and current ≤ 0.2%
Active and reactive power ≤ 0.5%
Power frequency ≤ ±0.01 Hz

Refreshing cycle
Telemetering, from acquisition input to communication interface output ≤ 3 sec
Telesignal, from change of state input to communication interface output ≤ 3 sec
Telecontrol, from command creation to communication interface output ≤ 1 sec
Updating period of analog quantities on chart ≤ 3 sec
Updating period of change of state on chart ≤ 2 sec
Switch over time of standby hosts ≤20s

Read more on the web


www.nrelect.com read more on www.nrelect.com 293
Characteristic Glass optical fiber
Optical fiber type Multi-mode
Connector type ST
Wave length 820nm
Minimum transmission power -25dBm
Margin Min. +3.0dB

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level
Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

294 read more on www.nrelect.com


PCS-9700 HMI

The PCS-9700 HMI (PCS-9700) is designed based on advanced - Operation management


distributed network technology, object-oriented database The system can give suggestions on typical failure, fault,
technology and cross-platform visualization technology. It is accident or normal operation, making operation statistics.
fully compatible with multiple International standards such as
IEC60870-5-103 and IEC61850. The PCS-9700 is suitable for - Self-diagnosis and self-restoration
conventional substations, smart substations, and NCS system in Software and hardware can be self diagnosed on-line. The
power plants. range of self-diagnosis objects include supervisory and control
uni-ts, various kinds of stations, communication interface, and
The system adopts distributed and expandable system other equipments, networks, channels, clock synchronism
framework to accommodate different structures. Applications and system and peripheral equipments.
databases can be flexibly configured on each computer node
without modification. The whole system comprises computers on
which different operating systems are installed. System functions
can be easily expanded according to user demands to realize
Features
system flexibility and scalability.
The PCS-9700 HMI fully satisfies customers’ requirements
though using up-to-date technology. It has advantages of high
reliability, extensibility, easy maintenance, friend user interface
Function and high system performance, and has the following features:

• Real-time data acquisition and processing • Module and object oriented technology are used to build up
• Control operation, synchronism checking and interlocking the system.
• Setup and maintenance of data base • The design adopts international standard such as C++, TCP/
• Reactive power and voltage automatic regulation IP, OLEDB, SQL and ActiveX etc.

• Configurable alarm processing • Supporting various interfaces, such as DDE and share
memory, supporting flexible network structure, connecting
• Sequence of events record and post-fault review
easily with other systems

- Configuration and displaying of graph and chart • Supporting cross platform function.
Interface editor is an important tool to generate geographic • The system can operate in UNIX, LINUX and Windows
graphs, single line diagrams, reports and bar charts. It provides platform and can be installed in computers with different OS.
convenient compilation function such as graph and report • Friendly HMI with online help function which is easy to learn
creation to make preparation work more convenient, fast and and use.
efficient.
• Adopting unified commercial and realtime database,
equipment oriented database management system to support
- List of events
equipment online configuration and realtime verification
The system can provide various information, such as protection
function.
information protection, list of protection events, real-time and
historical curves and real-time and historical reports. • Realizing network information by mutually exchanging,
processing and verifying technologies based on softbus
Besides, users can perform the following functions via the technology.
main interface, such as the reset of protection signals and • Switch over of redundant equipments without disturbance
configuration of protection setting, post-fault review and display through network and nodes redundant configuration.
of the result in picture form, and supervisory on communication • Well-designed online self-diagnosing function to identify the
bit stream, etc. failures of equipments and network on time.
• Self-restoration function helps system to restore to normal
- On-line calculation and reports preparing
operation mode if the program losses control.
Based on the real-time data acquired, the system can make
calculation on current, voltage, active and reactive power and • Having well-designed online self-diagnosing function, finding
power factor, statistics of maximum and minimum value per day, the failure of equipments and network of system on time,
month and year of assigned quantities and duration of these then giving alarming information
values’ occurrence. • Having self-restoration function, system can restore to the
normal operation mode if the program losses control.

read more on www.nrelect.com 295


PCS-9705
Bay Control Unit (BCU)

The PCS-9705 bay control unit is a flexible, easy-to-use


control unit used for measuring, monitoring and control
of various bays with different voltage levels. The modular
architecture, extensive functional library, programmable
logic and configurable I/O are supported to meet specific
application. It can be optimally tailored for various
applications including transmission lines, transformers, circuit
Functions breakers, busbars and reactors. The interlocking logic can
be configured to promote safe operation by preventing non-
• Measurements of current, voltage, frequency, harmonic (up permissible switching operations. IEC 61850-8-1 and IEC
to 15th), power factor, active/reactive power and energy 60870-5-103 for station bus, IEC61850-9-2 and GOOSE for
• Remote/local control of circuit breakers, isolators and earth process bus are supported.
switch
• Monitoring of circuit breaker, isolators and earth switch
• Operation counter of circuit breaker
• 1 RS-485 communication rear ports for GPS clock
• SBO (Select Before Operate) for remote control
synchronization, supports PPS, IRIG-B, SNP and IEC1588.
• Implementation of AGC (Automatic Generator Control)
• 1 RS-232 communication rear ports for printer
command (optional)
• 1 front plate RJ45 port for testing and setting
• Programmable Interlocking logic
• Synchro-check closing for circuit breakers
• Interface to transducer inputs or RTD inputs for temperature
Features
• Tap position supervision of transformer
• Supervision of busbar VT failure
• The relay is designed based on NR’s well established and
• Tripping circuit supervision proven UAPC hardware platform of multi-processor. Multi
• Bay mimic display in large scale LCD CPU modules are adopted in the relay. All CPUs can operate
• Master tripping lockout in parallel.

• Voltage and current drift auto adjustment • All AC quantity inputs can be sampled simultaneously to
• Self diagnostic test ensure the accuracy of analog quantity measurement which
is up to 15th harmonic component.
• Total 1024 SOE, including alarm, binary input change and
human operation reports • The BCU provides optional RTD input module and 4-20mA
• Up to 4 Ethernet ports with IEC 61850-8-1 for station bus DC input module for detection of temperature. And optional
4-20mA outputs are provided for AGC implementation.
• 2 optional fiber Ethernet ports for process bus, support
GOOSE and IEC61850-9-2 • Software and hardware timing are both adopted with 1ms
• 2 RS-485 communication rear ports conform to IEC 60870-5- timing accuracy to ensure the resolution of sequence of
103 protocol events.

Model PCS-9705A PCS-9705B PCS-9705C PCS-9705D PCS-9705E


AC inputs 5VT/4CT 13VT 8VT/7CT 24VT 13VT/12CT
Binary Inputs Up to 140 Up to 140 Up to 140 Up to 120 Up to 140
Binary Outputs Up to 25 pairs Up to 15 pairs Up to 25 pairs Up to 25 pairs Up to 25 pairs
Configurable Outputs Up to 50 Up to 50 Up to 50 Up to 50 Up to 50
DC Inputs(4-20mA,0-5V) Up to 12 Up to 12 Up to 12 Up to 12 Up to 12
DC Outputs(4-20mA) Up to 4 Up to 4 Up to 4 Up to 4 Up to 4
Synchro-check 1 breaker 0 2 breakers 0 3 breakers
Interlocking Logic Yes Yes Yes Yes Yes
Support to ECVT(optional) Yes Yes Yes Yes Yes
IEC61850 Process Bus(optional) Yes Yes Yes Yes Yes

Read more on the web


296 read more on www.nrelect.com www.nrelect.com
• The control circuits adopt many block, permit and verify • The network of equipments adopts 100M optic fiber or twisted
facilities, including bay level transverse interlock function based wire Ethernet.
on network communication so that the security of local and
• It adopts integral front plate and plug-in module structure. High
remote control can be ensured.
and low voltage circuits are separated strictly which enhances
• Large scale LCD provides graph and text man-machine- EMC immunity performance.
interface which makes operation and inter-rogation convenient.
• Low power consumption and wide ambient temperature range.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<20W (for conventional substation application)
Quiescent condition
<25W (for smart substation application)
Burden
<25W (for conventional substation application)
Operating condition
<30W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range 90% ~ 110% fn
Accuracy 0.2 class
Rated current (In) 1A 5A
Linear to 0.05In~2In
continuously 2In
for 10s 12In
Thermal withstand capability
for 1s 30In
for half a cycle 75In
Burden < 0.2VA/phase @In < 0.4VA/phase @In

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range 90% ~ 110% fn
Rated phase-to-phase voltage (Un) 100~130V
linear to 1~130V
Accuracy 0.2 class
continuously 130V
Thermal withstand capability 10s 200V
1s 250V
Burden < 0.10VA/phase @Un

Transducer Inputs
Standard IEC 60255-1:2009
Input range 0-20mA 0~5V 0~48V 0~250V
Input resistance 235Ω 4.4 kΩ 54.2 kΩ 248 kΩ
Accuracy 0.5 class 0.5 class 0.5 class 0.5 class

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 48V 110V 125V 220V 250V
Rated current 1.2mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 55%~70% of rated voltage
Maximum permissive voltage 120% rated voltage
Withstand 2000Vac, 2800Vdc

Read more on the web


www.nrelect.com read more on www.nrelect.com 297
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
Max system voltage 380Vac, 250Vdc 380Vac, 250Vdc
Voltage across open contact 1000V RMS for 1 minute 1200V RMS for 1 minute
5.0A @ 380Vac 8.0A @ 380Vac
Continuous carry
5.0A @ 250Vdc 8.0A @ 250Vdc
Pickup time <8ms <10ms
Drop-off time <5ms <8ms
6A@3s 10A@3s
Short duration current
[email protected] [email protected]
0.6A @ 48Vdc, L/R=40ms 0.6A @ 48Vdc, L/R=40ms
Breaking capacity (L/R=40ms) 0.1A @ 110Vdc, L/R=40ms 0.3A @ 110Vdc, L/R=40ms
0.05A @ 220Vdc, L/R=40ms 0.2A @ 220Vdc, L/R=40ms
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6× 177.0 ×230.2 (unit: mm)
Trepanning dimensions (W×H) 450.0×179.0, M6 screw (unit: mm)
Mounting Flush mounted
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- Ethernet Port for RTU/SCADA
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997, DNP 3.0 or IEC 61850
Safety level Isolation to ELV level

- Station Level Interface


Characteristic Glass optical fiber
Optical fiber type Multi-mode
Connector type ST, SC
Wave length 1310nm
Transmission distance <2000m
Minimum transmission power -20dBm
Reception sensitivity -30dBm
Margin Min. +3.0dB

- Process Level Interface


Characteristic Glass optical fiber
Optical fiber type Multi-mode
Connector type LC
Wave length 1310nm
Transmission distance <2000m
Minimum transmission power -20dBm
Reception sensitivity -30dBm
Margin Min. +3.0dB

- Print Port

Read more on the web


298 read more on www.nrelect.com www.nrelect.com
RCS-9700C
Bay Control Unit (BCU)

RCS-9700C series Bay Control Units are terminal units


used with SCADA to measure and control circuit breakers,
disconnectors, and transformers in power plants and
substations. The bay control units are fully compatible with
IEC 61850 communication. The RCS-9700C series BCUs
have 2 subfamilies: one for IEC60870-5-103, and the other
for IEC61850.
9701C

9702C

9703C

9704C

9705C

9706C

9707C

9708C

9709C

9710C
Module

Pulse accumulation 4 4 4 4 4 4 4 4 4 4
5VT 5VT 8VT 5VT 5VT 5VT 8VT
AC inputs 13VT 26VT 26VT
4CT 4CT 7CT 4CT 4CT 4CT 7CT
Transducer inputs 15 8 8 8 0 0 0 8 8 15
Binary inputs 134 56 56 80 62 62 86 56 56 134
Binary outputs 16 16 16 8 16 0 8 8 16 16
Analog output 0 0 0 0 0 0 0 4 0 0
CB Synchronization 1 0 1 2 1 0 1 1 2 0
Interlocking function √ √ √ √ √ √ √ √ √
Interlocking criteria
√ √ √ √ √ √
status output function
15th harmonic √ √ √ √ √ √ √ √ √ √

Features

• The equipment is designed based on a 32 bits CPU and DSP • Software and hardware timing adopts 1ms timing accuracy to
hardware platform. It adopts real-time multitasks operation ensure the resolution of sequence of events.
system with high processing ability. • The control circuits adopt many block, permit and verify
• The device adopts 14 bits high accuracy A/D converter so facilities, including bay level transverse interlock function
that all AC quantity inputs can be sampled simultaneously to based on network communication so that security of local
ensure the accuracy of analog quantity measurement. and remote control can be ensured.
• A group of voltage and current analog inputs, and the basic • The network of equipments adopts 100M optic fiber or twisted
contents consist of current, voltage, frequency, electric wire Ethernet. And It is convenient and easy to be setup.
energy calculation, power and power factor

Technical Data
Power Supply
Rated Voltage (Un) 48Vdc, 110Vdc/125Vdc, 220Vdc/250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:1979
Voltage dips and voltage short interruptions 20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms

Read more on the web


www.nrelect.com read more on www.nrelect.com 299
Quiescent condition <15W
Burden
Operating condition <25W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
20In 20In
Linear to (non-offset AC current)
2In (for metering) 2In (for metering)
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1988
Rated Voltage (Un) 100 V/√3, 110 V/√3 100 V, 110 V
linear to 106 V 175 V
continuously 173V 173V
Thermal withstand capability 10s 240 V 240 V
1s 300 V 300 V
Burden <0.2 VA/phase @ Un <0.5 VA/phase @ Un

Binary Inputs
Rated Voltage 110Vdc 220VdcC 125Vdc 220Vdc
Pickup voltage 77Vdc 154Vdc 87.5Vdc 175.0Vdc
Dropout voltage 60.5Vdc 121Vdc 68.8Vdc 137.5Vdc
Maximum permitted voltage 150V 300Vdc 150Vdc 300V
Withstand 2000Vac

Binary Outputs
Item Tripping contact Signal contact
Output model potential free contact
Max system voltage 250Vac/dc
Test voltage across open contact 1000VAC RMS fro 1minute
5A @250V AC 8A @250V AC
Continuous carry
0.3A @220V DC 0.3A @220V DC
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
482.6 × 266 × 291, (unit: mm), RCS-9701C,RCS-9710C
Enclosure dimension (W×H×D)
213.6 × 266 × 291, (unit: mm), others
450 ×267, (unit: mm), M6 screw, RCS-9701C,RCS-9710C
Trepanning dimension (W×H)
215 ×267, (unit: mm), M5/M6 screw, others
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Read more on the web


300 read more on www.nrelect.com www.nrelect.com
Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Connector type RJ45
Transmission Rate 100Mbps
Electrical Transmission standard 10Base-T/100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Ethernet Connector type SC
Transmission Rate 100Mbps
Transmission standard 10Base-T/100Base-TX
Optical Fiber Type ≤ 2000m
Optical
Wavelength Isolation to ELV level
Transmission distance < 1500m

Protocol IEC60870-5-103:1997 or IEC61850


Safety level Isolation to ELV level
Interfaces for Testing
Port number 1
RS-232 Baud rate 9600bps
Testing Method FTP or HyperTerminal
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA)
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns

Read more on the web


www.nrelect.com read more on www.nrelect.com 301
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


302 read more on www.nrelect.com www.nrelect.com
RCS-9698G/H
Gateway

RCS-9698G/H is used to establish a communication


links between substation and Load Dispatching Centers
or Grid Control Centers to achieve data exchange. It is
capable to communication with several dispatching centers
simultaneously via different telecommunication channels
Basic Communication Protocol according to the applied protocol. Industrial hardware
with embedded components are adopted instead of PC
• Upward communications: IEC 60870-5-101, IEC 61850- technology with weak rotary machinery (Hard disk, Cooling
5-104, MODBUS, CDT, DNP3.0, SCI1801, RP570 and Fan, etc.). RCS-9698G/H supports both conventional
further protocols on request communication channels and modern powerful Ethernet,
and is fully complied with IEC 61850 international standard
• Downward communications:IEC 60870-5-103 or IEC61850
communication protocol. RCS-9698G can be used
• It can cooperate with RCS-9794A/B to realize various independently, while RCS-9698H adopts duplicated scheme
protocols. with two RCS-9698G units to realize HOT-STANDBY or Dual-
HOT running mode.

Functions
- Collect Information from IEDs
Depending on the applied protocol and database configuration, so on.) and any desired RTU protocols (any new protocols are
and also owing to its powerful communication interface, RCS- provided on client’s request). Moreover, information sent to
9798G/H can communicate with various IEDs in a substation, dispatching center can be selected according to the necessity.
and automatically collect any wanted information from them,
e.g. sequence of events (SOE), binary signals, transformer tap - Information marshalling and synthesizing
position, pulse counting of electricity quantity, communication An important aspect of multiple protocol applications of RCS-
states and so on. In addition, all the collected information can 9698G/H (e.g. communicate with several dispatching centers) is
be sent to dispatching center. the proper marshalling of the data to be transferred according to
the appropriated RTU protocols. With the help of Configuration
- Small-capacity memory storage Tool, signal synthesization is implemented, such as General
With small-capacity of industrial-grade NANDFLASH memory Alarm, General Failure.
(128MBytes for single machine while 256MBytes for dual
machine system), information of events(protection relays’ self- - Signal transmitting
checking information, trip event records, fault information, Depending on the utilized RTU protocol, all the collected signals
settings modification records and so on), remote command can be selectively sent to dispatching center. Signal selection
from dispatching center including selecting and executing of the can be done during RCS-9698G/H database configuration by
binary output and setting modifications, remote regulation of Configuration Tool.
transformer tap position, remotely signal reset event and so on
are stored, which are automatically collected from various BCU, - Multiple Switchover Scheme for Dual-machine
protection relays and some other auxiliary IEDs. Configuration
Whenever an error happens in the HOST MACHINE (e.g.
- Settings management CPU or power supply failure), the HOT STAND-BY MACHINE
RCS-9698G/H can upload/download and modify settings (only will be forced to be as a host one. With a dedicated seamless
the currently activated group of setting can be managed) of switchover technique, the equipment will guarantee that records
various expected protection relays and auxiliary IEDs. Setting are not lost during a switchover. There are up to four kinds of
management can be done by Debugging Tool or achieved by dual-machine switching scheme.
dispatching center up to the applied protocol.
- Time Management
- Communicate with dispatching center via various As the equipment Real Time Clock has small drift per day,
protocol and interfaces therefore, in order to have a correct time for time tagging of
Appreciated to its powerful communication function, RCS- event etc., the operator should set its time periodically or it
9698G/H can send all collected information to dispatching should be synchronized by a master clock. With a correct clock,
center via multiple standard communication interface (e.g. the equipment can be configured to synchronize its managed
electrical/optical Ethernet port, electrical/optical serial port and IED’s clock.

Read more on the web


www.nrelect.com read more on www.nrelect.com 303
- Diagnostic • Well-done network protocol stack effectively against virus
The equipment can continuously self-supervise on its firmware. and enforcing the reliability
Once a hardware/software fault happens; its watchdog will
• Configurable communication interfaces
make the CPU card restart.
• Hardware time synchronization (IRIG-B standard and
differential pulse per minute (PPM) and pulse per second
Features (PPS))

• Electrical (high speed optical-coupler isolated)/optical


• Applicable to new substations or modernization of existing serial interfaces
substations
• Electrical/optical Ethernet interfaces (100Mbits/s)
• Fit for installation in cubicles
• LCD display with 25 LED indicators and dedicated keypad
• Supporting dual machine system configuration with the
• Data marshalling and distribution
merit of absolutely electrical independence
• Continuous self-monitoring
• Embedded multiple processor architecture, all processors
are mutually independent and parallel running. Moreover, • Continuous supervision on connected device
the equipment can equalize load among each processor. In
• Powerful and friendly configuration tool and debugging tool
this way, it exploits the merit of distributed multiprocessor
system’s parallel processing ability. • Common functions (e.g. general alarm, general fault signal,
communication monitoring, etc.)

Technical data
Power Supply
Rated Voltage (Un) 110V/125Vdc, 220V/250Vdc, 48V DC
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Burden 45W for single machine, 90W for dual machine configuration
Backup battery type ML2032, 3V, 65mAh

Mechanical Specifications
Enclosure dimensions 482.6×177.0×291 (unit: mm)
Trepanning dimensions 450.0×179.0, M6 screw
Mounting Way Flush mounted
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Ethernet channel interfaces
Single machine: 4 ~ 16
Port number
Dual machine: 8 ~ 32
Connector type RJ-45
Ethernet Transmission Rate 10M/100Mbps auto-negotiation
Transmission standard 10Base-T/100Base-TX
Transmission distance < 100m
Safety level Isolation to ELV level

Read more on the web


304 read more on www.nrelect.com www.nrelect.com
Digital channel interfaces
Port number Up to 12/24 (single machine/dual machine)
Baud rate 300, 600, 1200, 2400, 9600, 19200 or 38400 bps
RS-232/422/485 (EIA) Transmission distance < 1000m@4800bps
Maximal capacity 32
Safety level Isolation to ELV level
Analog channel interfaces
Port number Up to 6/12(single machine/dual machine
Baud rate 300bps, 600bps, 1200bps, asynchronous
MODEM
Center Frequency 1080 ~ 3000Hz
Offset Frequency ±150 ~ ±500Hz
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 305
RCS-9794A/B
Protocol Converter

The RCS-9794A/B protocol converter is an integral part


of PCS-9700 substation automation system. It is used to
establish reliable and flexible communication links between
IEDs and workstation.

As a powerful and multifunctional communication and


Basic Communication Protocol data storage equipment, the RCS-9794A/B builds a bridge
between workstation and IEDs using different protocol from
• Upward: IEC 61850, IEC 60870-5-103
other venders. With its modular configuration, it is flexible
• Downward: IEC 60870-5-101, IEC 60870-5-103, IEC to add new protoco. The device is fully complied with
61850-5-104, MODBUS, CDT, DNP 3.0 (serial port). IEC61850 communication protocol. RCS-9794A can be used
• NR can customize new protocols as per the specific independently, and RCS-9794B adopts duplicated scheme
application with additional charge. with two RCS-9794A units to realize HOT-STANDBY or Dual-
HOT running mode.

Functions
• Universal protocol converter
The RCS-9794A/B is a highly-reliable, fully non-blocking
intelligent protocol converter, which supports interworking
between a wide range of protocols.
Features
• Various communication protocols can be selected flexibly for
• Linking protection equipments and other IEDs to substation
each communication port,
automation system
The RCS-9794 can send data from protective relays and • Suitable for installation in cubicles.
other IEDs to SAS. It also can send the control commands
of SAS to local bay units. • Supporting dual machine system configuration with the merit
of absolutely electrical independence.
• Linking protection equipments and other IEDs to remote
• Dual Ethernet communication is used for the upward
terminal units
communication with local HMI or RTUs at station level to
The RCS-9794 can send data from protective relays
ensure the reliability of all upward communication.
and other IEDs to RTUs. It can also send the remote
commands of remote control center to local bay units. • Embedded multiple processor architecture, all processors
are mutually independent and parallel running. Moreover,
• Inspection and monitor of communication status the equipment can equalize load among each processor. In
The RCS-9794 can inspect and monitor the communication this way, it exploits the merit of distributed multiprocessor
status of various equipments. If a connection or a
system’s parallel processing ability.
disconnection happens, the RCS-9794 will send the
change-of-state message to a station level device, such as • Configurable communication interfaces.
a local HMI or RTU.
• Hardware time synchronization (pulse per second (PPS))
• Clock synchronization and system time unification
• Various communication interfaces can be selected flexibly
The RCS-9794 can receive Pulses Per Second (PPS)
according to the engineering requirements. Serial ports,
and the timing messages from a GPS device. It will also
copper Ethernet ports, fiber serial ports and fiber Ethernet
synchronize its clock with the GPS device and send the
timing messages to the equipments that are connect to it. ports can be selected.

• Data marshalling and distribution


• Information synthesis and transmission
According to the engineering requirements, the RCS-9794 • Continuous self-monitoring
can synthesize several signals to one signal, and send this
• Continuous supervision on connected device
synthetic signal to the control center appointed by users.
• Powerful and friendly configuration tool and debugging tool
• Self-diagnosis
The RCS-9794 keeps checking for any hardware or • Common functions (e.g. general alarm, general fault signal,
software fault continuously when it is in operation mode. communication monitoring, etc.)

Read more on the web


306 read more on www.nrelect.com www.nrelect.com
Technical data
Power Supply
Rated Voltage (Un) 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11
Per IEC 61000-4-11:2004, IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Burden <50W

Mechanical Specifications
Enclosure dimensions (WxHxD) 482.6 × 177 × 291 (Unit: mm)
Trepanning dimensions 450×179, M6 screw
Mounting Way Flush mounted
Front side: IP51
Protection class Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +60°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Serial Interfaces
Baud rate 300bits/s ~ 38400bits/s
Copper Transmission distance < 1000m@4800bps
Safety level Isolation to ELV level
Baud rate 300bits/s ~ 38400bits/s
RS-232/422/485 Optical Fiber Type Multi-mode
Connector type ST
Fiber
Wavelength 850nm
Transmission distance ≤ 2000m
Safety level Isolation to ELV level
Baud rate 9600bits/s
Copper
Safety level Isolation to ELV level
Connector type 9600bits/s
LonWorks Optical Fiber Type Multi-mode
Connector type ST
Fiber
Wavelength 850nm
Transmission distance ≤ 2000m
Safety level Isolation to ELV level
Ethernet Interfaces
Connector type RJ-45
Transmission Rate 100Mbits/s
Copper Ethernet Ports) Transmission standard 100BASE-TX
Transmission distance < 100m
Safety level Isolation to ELV level
Connector type SC
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Fiber Ethernet Ports Optical Fiber Type Multi-mode
Wavelength 1300nm
Transmission distance < 2000m
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 307
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA)
Timing standard PPS
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


308 read more on www.nrelect.com www.nrelect.com
PCS-9881/ 9882
Ethernet Switch

PCS-9881 and PCS-9882 Ethernet switches are intended


for the interconnection of 10/100/1000M adaptive Ethernet
devices using twisted-wire/Fiber optical connection in
substation automation system. It adopts industrial level
components and chips to ensure the reliable and high-
Functions speed data exchange so as to compensate the insufficient
application of commercial switch in a substation automation
system. The PCS-9881 and PCS-9882 are fully compatible
Fully compatible with IEC 61850, GOOSE and smart
with IEC 61850 and GOOSE communication in a smart
substation
substation automation system with distributed network or ring
• Support QoS (IEEE 802.1p) message priority contro. network.
Four queues are provided to ensure the priority of
important message in GOOSE.
• Message from two or more interfaces can be integrated
to supervisory port via mirror image technology.
• Single-mode and multi-mode optical transceiver are • Link aggregation: support link aggregation based on
available. port, MAC address, and etc.
• QoS control: support message priority control based
Ethernet Interfaces
on IEEE 802.1p and strict priority & weighted priority
• Ten 10/100M/1000Mbps self-adaptive ethernet ports, strategy.
supporting MDI/MDIX automatic identification, adaptive
to crossover and straight-through network cable. VLAN
• The 100Mbps fiber ports adopt SFP slot, the optical • Supporting port-based VLAN
transceiver complying with IEEE802.3 100BASE-FX • Supporting IEEE 802.1Q-based VLAN
fiber ethernet standard can be adopted to support hot
• Supporting the intercross VLANs setup.
plugging.
• Supporting inserting, modifying or deleting the VLAN
• Six 1000Mbps SFP slots complying with IEEE802.3
tags of messages.
1000BASE-SX 1000Mbps ethernet (1.25GBd) standard
can be adopted to support hot plugging.
Supporting Redundant Ring Net
• Switching mode adopts non-blocking store and forward.
• Supporting STP (802.1D) and RSTP (802.1w), fast
• Supporting 802.3x Flow Control. switch to backup link in case of communication link
failure.
Flow Control
• Supporting connection via ring net.
• Networking storm suppression: set the upper limit
of forwarding rate of broadcasting, multicasting and Management
addressing-failure message of switches. • Supporting command line management such as Web,
• Port rate control: set the upper limit of message Telnet and CLI.
forwarding rate and burst rate of each port. • Supporting simple network management protocol
• Flow imaging function: monitor the inflow/outflow data SNMP v1/v2c.
from other ports to a specified port.

Technical Data
AC Power Supply
Rated Voltage (Un) 110V AC, 220V AC
Variation (80% ~ 120%)Un
500ms for interruption without de-energizing, dips 60% of Un without reset up to 12 cycles;
Voltage dips and voltage
dips 30% of Un without reset up to 30 cycles;
short interruptions (IEC 61000-4-11:2004)
dips 20% of Un without reset up to 300 cycles

Read more on the web


www.nrelect.com read more on www.nrelect.com 309
PCS-9882A, PCS-9882C, PCS-9882D: <20W
Burden
PCS-9882B: <40W

DC Power Supply
110V DC, 125V DC, 220V DC, 250V DC;
Rated Voltage (Un)
48V DC power supply is available if a specified power supply module is selected
Variation (80% ~ 120%)Un
IEC 61000-4-17:2002
Ripple in the DC auxiliary voltage
Max 15% of the DC value.
IEC 61000-4-29:2000
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
PCS-9881: <13W
PCS-9882A: <10W
Burden (no load) PCS-9882B: <9W
PCS-9882C: <8W
PCS-9882D: <8W
PCS-9881: <26W
PCS-9882A: <16W
Burden (Full load) PCS-9882B: <31W
PCS-9882C: <14W
PCS-9882D: <14W

Mechanical Specifications
Enclosure dimensions (WxHxD) 482.6 ×44.4 ×216 (Unit: mm)
Trepanning dimensions 450×44.45 (unit: mm), M6 screw
Upper/Left/Right side: IP50
Protection class Front side: IP40, up to IP51
Rear side: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Interface Type RJ45
Transmission Rate 100Mbits/s
100Mbits/s Ethernet Port Transmission standard 10Base-T/100Base-TX
Transmission distance < 100 meters
Safety level Isolation to ELV level
Characteristic Glass optical fiber
Connector type LC
Transmission standard 100Base-FX
50/125 multi mode fiber
100Mbits/s Optical Fiber Port
Fiber type 62.5/125 multi mode fiber
9/125 single mode fiber
Multi mode: <2km
Transmission distance
Single mode: <40km
Characteristic Glass optical fiber
Connector type LC
Transmission standard 100Base-FX
50/125 multi mode fiber
Fiber type 62.5/125 multi mode fiber
1000Mbits/s Optical Fiber Port 9/125 single mode fiber
Multi mode: <500m
Single mode: <10km
Transmission distance If procured by users themselves, the
transmission distance is subject to
the SFP transceiver module.

Read more on the web


310 read more on www.nrelect.com www.nrelect.com
Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 311
RCS-9785C/D
GPS Synchronization Clock

The RCS-9785C/D is a GPS Synchronized Unit with built-


in GPS receiver module. It receives the timing messages
through built-in GPS receiver module or receives IRIG-B
standardized timing code through one of the two input
channels, decodes and converts the timing code, and then
outputs timing signals to the whole station. The output timing
Features signals can be IRIG-B signals, pulse per second (PPS)
signals, pulse per minute (PPM), pulse per minute (PPH)
• Highly accurate time signal output signals and timing messages. It also can provide Ethernet
The device realizes a precision with respect to ±1μs for IRIG-B/ clock synchronization service (CSS) for bay units. The
PPS/PPM/PPH time signals (excluding the propagation delay Ethernet CSS can work in the dual Ethernet mode (RJ45
time on the cable). The pulse front edges of these time signals over 100BASE-TX).
are less than 50ns.

The inaccuracies of IRIG-B/PPS/PPM/PPH output signals of RS-


485 and TTL are ≤100ns.
• Application to a large system
The inaccuracies of IRIG-B/PPS/PPM/PPH output signals of The device is equipped with enough ports for output. The RCS-
optic-coupled dry (potential-free) contacts are ≤3μs. 9785E can be used to multiply time synchronizing pulse to meet the
demands if required.
• Various output interfaces of the time signals
The RCS-9785C/D can provide electrical (including RS-232/RS- • High reliability
485, TTL, and AC modulation) or optical output timing signals. The use of high-integration circuits and modular design technology
The timing signals supports IRIG-B, PPS, PPM, PPH and etc. in the RCS-9785C/D enhances the reliability of device.

Technical Data
Power Supply
Rated Voltage (Un) 110Vdc/125Vdc, 220Vdc/250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:1979
Burden <40W

Binary Outputs
Item Signal contact
Output model Potential-free contact
Max system voltage 380Vac, 250Vdc
Test voltage across open contact 1200V RMS for 1min
8.0A @ 380Vac
Continuous carry
8.0A @ 250Vdc
0.7A@48Vdc
Breaking capacity at 250Vdc 0.3A@110Vdc
0.2A@220Vdc
10A@3s
Short duration current
[email protected]
Pickup time < 10ms
Dropout time < 8ms
Bounce time 1ms

Read more on the web


312 read more on www.nrelect.com www.nrelect.com
Mechanical Specifications
Enclosure dimension (W×H×D) 482.6×177.0×291.0, (unit: mm)
Trepanning dimension (W×H) 450.0×179.0, (unit: mm), M6 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +60°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Ports to Transmit Clock Synchronization Signals
Connector type RJ45
Transmission Rate 100Mbps
Transmission standard 10Base-T/100Base-TX
Ethernet
Transmission distance < 100m
Protocol SNTP
Safety level Isolation to ELV level
Synchronization Standard Serial Port Timing Messages(9.6kbit/s) or IRIG-B
Transmission distance <30m
RS-232
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable
Synchronization Standard Serial Port Timing Messages(9.6kbit/s) or IRIG-B
Transmission distance <500m
RS-485 (EIA)
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable
Characteristic Glass optical fiber
Connector type ST or SC
Fiber type 62.6/125 μm for multi-mode
Transmission standard(for IEEE1588) 100Base-FX
Optical Fiber Port
Protocol IRIG Standard 200-04 or IEEE1588
Transmission distance <2km
Wave length 820nm
Synchronization Standard IRIG-B
Output voltage 0 - 5V
Output impedance 50Ω
TTL Port
Transmission distance <100m
Safety level Isolation to ELV level
Ports to Receive Clock Synchronization Signals
Synchronization Standard IRIG-B
RS-485 (EIA) Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable
Synchronization Standard IRIG-B
TTL Port Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable
Characteristic Glass optical fiber
Connector type ST
Optical Fiber Port Fiber type 62.6/125 μm for multi-mode
Wave length 820nm
Synchronization Standard IRIG-B

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

Read more on the web


www.nrelect.com read more on www.nrelect.com 313
- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


314 read more on www.nrelect.com www.nrelect.com
RCS-9785E
Time Pulse Extension Equipment

The RCS-9785E is a timing signal expansion unit without


internal GPS module. It receives IRIG-B standardized timing
code from the external GPS timing source, decodes and
converts the timing code, and then outputs expanded timing
Features signals to the whole station. The expanded timing signals
are IRIG-B signals, pulse per second (PPS) signals, pulse
• Highly accurate time signal output per minute (PPM), pulse per hour (PPH) signals and timing
messages.
The device realize a precision of ±1μs for IRIG-B, PPS, PPM and
PPH time signals (excluding the propagation delay time on the
cable). The pulse front edges of these time signals are less than
50ns.

The inaccuracies of IRIG-B/PPS/PPM/PPH output signals of RS-


485 and TTL are ≤100ns. • Application to a large system
The RCS-9785E is equipped with enough ports for output, the
The inaccuracies of IRIG-B/PPS/PPM/PPH output signals of time distribution can be made to multiple devices separated from
optic-coupled dry (potential-free) contacts are ≤3μs. each other by a maximum of 1km (when the optical ports are
applied).
• Various output interfaces of the time signals
The RCS-9785E provides electrical (including RS-232/RS-485, • High reliability
TTL, and AC modulation) or optical clock output timing signals. The use of high-integration circuits and modular design technology
The timing signals supports IRIG-B, PPS, PPM, PPH and etc. in the RCS-9785E enhances the reliability of device.Technical Data

Technical data
Power Supply
Rated Voltage (Un) 110Vdc/125Vdc, 220Vdc/250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:1979
Burden <40W

Binary Outputs
Item Signal contact
Output model Potential-free contact
Max system voltage 380Vac, 250Vdc
Test voltage across open contact 1000V RMS for 1min
Continuous carry 8.0A
0.4A resistance
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms)
Short duration current 50A for 200ms
Pickup time 5ms/10ms
Dropout time < 8ms
Bounce time 1ms

Mechanical Specifications
Enclosure dimension (W×H×D) 482.6×177.0×291.0, (unit: mm)
Trepanning dimension (W×H) 450.0×179.0, (unit: mm), M6 screw
Mounting Flush mounted
Front side: IP51
Protection class (per IEC60529:2001) Rear side, connection terminals: IP20
Other Sides: IP30

Read more on the web


www.nrelect.com read more on www.nrelect.com 315
Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces to connect the synchronized devices
Port number 7 per module
Connector type RJ45
Transmission Rate 100Mbps
Transmission standard 10Base-T/100Base-TX
Ethernet
Transmission distance < 100m
Protocol SNTP
Safety level Isolation to ELV level
Port number 7 per module
RS-232 Transmission distance <30m
Safety level Isolation to ELV level
Port number 7 per module
Maximal capacity 32
RS-485 (EIA)
Transmission distance <500m
Safety level Isolation to ELV level
Port number 8 per module
Operating voltage ≤ 300Vdc

Optic-Coupled Dry Contact Operating current ≤ 60mA


Transmission distance < 200m

Safety level Isolation to ELV level

Port number 8 per module


Connector type ST
Fiber type 62.6/125 μm for multi-mode
Wave length 820nm
Optical fiber The optical fiber has light in it when the channel is idle.
Transmission mode Or:
The optical fiber has no light in it when the channel is idle.
Transmission distance < 2000m
Safety level Isolation to ELV level
Port number 8 per module
Output voltage 0 - 5V
TTL Port Output impedance 50Ω
Transmission distance <100m
Safety level Isolation to ELV level
Ports to Receive Clock Synchronization Signals
Port number 2
RS-485 (EIA) Synchronization Standard IRIG-B
Safety level Isolation to ELV level
Port number 2
TTL Port Synchronization Standard IRIG-B
Safety level Isolation to ELV level
Port number 2
Connector type ST
Fiber type 62.6/125 μm for multi-mode
Wave length 820nm
Optical Fiber Port The optical fiber has light in it when the channel is idle.
Transmission mode Or:
The optical fiber has no light in it when the channel is idle.
Synchronization Standard IRIG-B
Safety level Isolation to ELV level

Read more on the web


316 read more on www.nrelect.com www.nrelect.com
Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Radio frequency interference tests Per IEC 60255-22-3:2007 class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 317
Power Plant Automation System

PCS-9100
Distribution Control System for
Thermal Control (DCS)

The PCS-9100 series distribution control system is a • Control system for auxiliary generator: The PCS-9100 series
comprehensive control platform intended for the application realizes safe and integration control for auxiliary generators
to main generators and auxiliary generators in power plants in thermal power plant by platform construction, which
and process control in industrial fields. The PCS-9100 series provides various process controls for auxiliary generators
is designed based on the deep cooperation with a worldwide with highly control safety and stability.
well-know DCS manufacturing company and integrates NR’s
• The PCS-9100 series adopts distribution control platform
technical advantage in power plant and thermodynamic
from Honeywell, US.
measurement. It provides distributed control and centralized
operation, which makes the system flexible to configure and
easy to maintain.

Features
Functions • Integrated design method which is of high reliability and
availability.
• Control system for main generator: The PCS-9100 series
realizes integrated turbine, boiler and electric control which • High-tech application platform with integrated database and
are applicable for all kinds of power plants. It adopts many advanced application software package.
powerful functions incorporates data acquisition system, • System diagnostic and performance analysis capabilities.
modulating control system, sequence control system, furnace
safeguard supervisory system, electrical control system and • Providing remote diagnostic, digital graphic management
digital electric-hydraulic control system. system and complete security protection for both system and
devices.

318 read more on www.nrelect.com


TPS Multiple network system • Detail Displays
• EtherNet (100M/1000M) - Individual data points / Process modules
• LCN (10M) • System Function Displays
- NIM / Datahiway/HG-to Conect multiple TPS system - Organizational Summary Displays
- PLC net gateway:EPLCG, CLM - Unit Point / LCN Node Point / UCN Node Point
- DECNET:PLNM • Reporting Function Displays
- LCN gateway:NG
Report / Log / Trend / Journal
- History Model:HM
• System Functions
- Application Model:AM
Clear Screen / NCF Status / etc.
Universal Control Network • Realistic custom displays better reflect your process
• UCN (5/10M) - Rainbow of colors
- High-performance process station - Animation
- Logic Manage station - Three-dimensional look
- Safe Manage:FSC-SM - Photographs
- Microsoft OLE container, MS OLE
High-Performance Process Manager
• OLE control objects help youquickly initiate or respond to
• Process control process actions, invoke related displays or applications
• Discrete (motor) control
• OLE applications can be embedded directly into displays
• Batch sequencing
- Spreadsheets, safety documents, emergency procedures,
• Process optimization audio, video
• Remote I/O
• Subsystem interfaces
• Peer-to-peer communication
• Intelligent high density I/O
• Foundation for a TotalPlant Solution System

GUS Display and Display Builder

• Process Displays
- Area Displays
- Overview / Trend (24points/12axes)/ Sequence Module /
Message
- Alarm (Summary / Annunciator)
• Unit Displays
- Trend / Alarm Summary
• Group Displays
- Group / Group trend (8points/2axes)/ Hourly Averages /
- Process Module Group

read more on www.nrelect.com 319


PCS-9700
Electrical Control System for
Motor Control (ECS)

The PCS-9700 Electrical Control System is designed based the traditional centralized structure, and this makes the system
on a large scale of object-oriented software platform to realize more reliable, easier to extend and maintain.
hierarchical distributed control functions via Ethernet, including
protection, measurement and monitoring. The integrated design and practice in the PCS-9700
considerably reduce the cost of multiple stand-along devices.
The PCS-9700 series ECS system is a cost effective auxiliary Furthermore, direct connection between the bay-level devices
BCU of a DCS system for the power plant electrical system. It and the dual Ethernet networks can enhance reliability of the
provides high performance bay control for the auxiliary system ECS system.
in power plant, such as start-up/stand-by transformers, auxiliary
transformers, DC power supply system and other intelligent NR’s PCS-9700 series ECS system are fully compatible with
devices. The system adopts bay-oriented and object-oriented IEC61850 standard and they have been applied to many power
configuration with layered distributed architecture to replace plants and put into service successfully already.

320 read more on www.nrelect.com


PCS-9700
Network Control System for
power plant (NCS)

The PCS-9700 Network Control System is a monitoring system whole system is designed elaborately which makes each device
designed for power system network of all voltage levels. It safe, reliable and easy for communication. By using component
provides variety monitoring functions including: technology, the PCS-9700 NCS realizes plug and play of
hardware and software function. Anti-interference capability
• Safety monitoring of electrical devices
ensures long-term safety operation of network devices under
• Complete telecontrol functions for power system dispatching, complex industrial environment. The software and hardware
incorporating remote metering, remote dispatching, remote platform of e network communication devices are composed
control and remote signal transmit. of innovative embedded processor, real-time multifunction
• Real-time monitoring of electrical parameters and other operating system and accurate synchronization system. The
electrical devices if necessary operation system of PCS-9700 NCS series is compatible with
Windows and UNIX system.
• AGC and AVC functions
• Power plant operation management and economic power
NR’s PCS-9700 NCS system is fully compatible with IEC61850
distribution between each generator set.
standard and they have been applied to many power plants and
put into service successfully already.
The PCS-9700 series NCS system adopts object-oriented
structure which is flexible to configure and easy to extend. The

read more on www.nrelect.com 321


PCS-9400
Generator Excitation System

The PCS-9400 generator excitation system can improve • Thyristor rectifier


generator performance and reduce maintenance costs. It A lot of levels of current output are supplied to match the
provides complete control functions, including power system requirements of users, i.e. 250A, 800A, 1200A, 1800A and
stabilizer, optimum control, adaptive control and other functions. 2400A. Parallel-connected multi-cabinet operational mode
The PCS-9400 can be customized with a wide range of options is adopted. The coefficient of equalizing current is larger
to meet various specifications from customers. than 0.9. Aluminum Radiator or Heat Pipe Radiator can be
selected alternatively.
The range of rated currents is 100A to 7000A and the range of
voltages is 100V to 700V. • Diode rectifier
A lot of levels of current output are supplied to match the
PCS-9400 system is available for various excitation types,
requirements of users, i.e. 1800A, 2400A and 3000A.
including:
Parallel-connected multi-cabinet operational mode is
• Stationary excitation system
adopted. The coefficient of equalizing current is larger
• One-generator and one-excitation system than 0.9. Aluminum Radiator or Heat Pipe Radiator can be
• One-generator and two-excitation system selected alternatively.
• Brush-less excitation system
• De-excitation cabinet
• DC exciter excitation system
Linear or nonlinear resistor and field breaker are supplied in
PCS-9400 system consists of the following equipment: de-excitation equipment. And overvoltage protection is also
equipped with.
• Numerical excitation regulator
• Thyristor rectifier
• Auxiliary cabinet
• Diode valve rectifier Special devices for complicated requirements and logic
• De-excitation equipment circuits are equipped with the cabinet.
• Auxiliary cabinet
According to the different requirements of each excitation type,
all equipment can be flexibly selected to combine to compatible Features
excitation system.
• The AVR uses high-performance CPU as the core, and
adopts high precise multi-point AC sampling technology, and
• Numerical excitation regulator.
all the control, regulation, protection function are realized by
It consists of dual-channel configuration or three-channel the module software.
configuration. Each channel is an independent regulation
unit based on advanced hardware platform, which is based • Rectifier cabinet has high capacity. Cooling Rectifier cabinet
on multi-processor system including DSP, ARM and CPU. is with outstanding cooling ability.
The system provides all essential functions, such as PID • A lot of elements and protections are supplied for complete
regulation+ PSS strategy, many closed-loop and open- control function of excitation system.
loop control laws, difference regulation, many limiters and
protections, i.e. under-excitation limiter, over-excitation • Parallel-connected dual-cabinet operational mode without
limiter, false strong excitation limiter, peak current limiter, switchover process has more reliability.
V/F limiter, overvoltage protection on no-load, TV signal
• Trending and recording data are provided. The user can
failure protection etc. And self-diagnose function, fault-
search the data one second before fault. The system
tolerance control element, oscilloscope and event recording
constantly measures AC current and voltage of generator,
function are all equipped with. The HMI with a LCD and a
active power, reactive power and power factor, etc.
9-button keypad is friendly to users. And it is also easy to
communicate with PC at higher level. Ethernet interface, 2 • The user can configure and troubleshoot PCS-9400 via the
CAN bus interfaces (Used for internal communication) and communication network.
RS-232/RS-485 serial ports are supplied for communication.

322 read more on www.nrelect.com


Principle of Static Excitation System

Panel Layout of Excitation System

• Allowable time for excitation system operation at 1.8 times


nominal excitation current is longer than 10s without damage.

• The excitation system is a high initial response system.


The voltage response time will not exceed 0.08 s in voltage
increasing(force excitation) and will not exceed 0.15s in
voltage decreasing(rapid de-excitation and ceiling voltage
reducing to zero)

• The excitation system can ensure continuous normal


operation of the generator, when voltage and frequency of
the station service power varies in the following manners:

• AC: -15%~+15%of rated value.

• DC: -20%~+20% of rated value.

• Frequency deviation: -5~+22.5Hz. of rated frequency

• The excitation system is able to control generator voltage


change less than 0.25% when generator frequency changes
for 1%.

• Excitation system parameters such as gains, time constants


feedback signals and reference signals, etc. are adjustable
ranges and proposed settings are recommended by the
Excitation System Duties
supplier. Equipment are properly shielded and willl not be
effected by electromagnetic interference. Ratings, tests and
The excitation system supplied meets the following technical
characteristics are in accordance with the latest approved
requirements:
standards of IEEC and IEC.
• The excitation system can supply continuously excitation
current required by the generator under all operating • The excitation control can be arranged for both local
conditions. and remote operations. Unless otherwise specified, all
• The excitation is capable of supplying continuously 1.1 times accessories required for control system interface can
the field Voltage and field current needed for the rated power be provided by supplier whether or not such items are
output of generator. specifically mentioned in contract documents.

• The excitation system is capable of continuously supplying • All control operations, detailed alarms and operating
ceiling voltage 1.8 times the generator rated field voltage for conditions are possible and activated by an operator panel
mounted in front door of the AVR (Automatic Voltage
15 seconds.
Regulator) cubicle.

read more on www.nrelect.com 323


PCS-9575
Static Frequency Converter (SFC)

The static frequency converter (SFC) is a speed governing


system for large capacity synchronous motor starting or its
speed control in pumped storage power plant, gas turbine
power plant and industrial enterprise. It supplies current with
varying frequency to the stator of motor to control the motor
speed.

NR’s PCS-9575 static frequency converter system is based


on NR’s widely used UAPC platform, successful thyristor
application, real-time close loop control technologies and
experience in high voltage design & production.

Pumped storage power station - Converters


The SFC is used control the motor startup from 0Hz to 50Hz (or The converter can be high-low-high type, high-high type or
60Hz) before it operates in pump mode. SFC makes the motor 12/12-pulse type, 12/6pulse type, 6/6pulse type; two converters
switch smoothly without impact on grid operation. are connected by a DC reactor which is necessary for the
current source type SFC.
Gas turbine power plant -Cooling
In gas turbine power plant, SFC system is used to drive The cooling system can be AL-radiator+forced-air cooling or
the generator unit through purging, warming , firing and water cooling depending on the capacity of SFC.
accelerating.
-Control unit
The control, protection and monitoring functions are integrated
Other industrial enterprises
in the controller.
The SFC system can be used for initial start and speed control
in other industrial enterprises where synchronous motors with
large capacity are widely used.
Functions and Features
• NR’s PCS-9575 static frequency converter system features
Configuration advanced and reliable hardware platform, high level EMC,
photoelectric triggered converter bridge, excellent operation
NR’s PCS-9575 static frequency converter system is composed performance and easy maintenance.
of power input/output, frequency converter and control &
• Distributed multi-CPU structure.
protection device. Two identical thyristor converters are
connected in three-phase bridge connection to form the power • High integrated system.
converter.
• Pulse generation with great stability and reliability.
- Breakers/switches
• Realtime fast data communication.
The SFC system is equipped with input breakers and output
• Compact system design to enhance reliability and EMC.
breakers. A bypass switch shall be installed if an output
transformer is configured. • Automatic testing function.

• Variable speed driving of great stability and reliability;


- Transformer
The input transformer can be isolating transformer or step- • Powerful wave recording and convenient analysis.
down transformer. It connects to the power source via power
• Extensive self-check.
converter. The output transformer is optional.
• Suppporting various communication protocol.

324 read more on www.nrelect.com


FLEXIBLE AC TRANSMISSION

PCS-9580
Static Var Compensator (SVC)

NR’s PCS-9580 Static Var Compensator(SVC) system is a


reactive power compensation system with integrated control
and protection system. It is built based on high power thyristor
technology used to improve power system transmission and
distribution performance. Stability and economy of power
grid operation can be affected by active and reactive power
disturbances caused by connections/disconnections of large
load or some other system faults. The resulted overcurrent
and overvoltage may damage the related electrical apparatus.
The PCS-9580 static var compensator system can adjust the
reactive power in the power grid expeditiously to achieve a
reasonable power flow distribution.

Compared with traditional reactive power compensation


methods, the PCS-9580 SVC system has extensively gained a
significant market, primarily because of its superior performance Figure 1. Static Var Compensator
to supply dynamic reactive power with fast response time and
with low-cost maintenance.
Distribution system
PCS-9580 SVC can be connected to the terminal substation
in power distribution system to reduce reactive power
Applications consumptions, improve power factor, reduce distribution system
losses and decrease damages caused by frequent switch-in of
A complete set of SVC system can be used to generate capacitor banks.
constantly varied inductive and capacitive reactive power with
Benefits
fast response time. So far, SVC system has been extensively
used in electric power system and industrial field. • Reduce reactive power exchange and improve system
stability
Power transmission • Improve power factor and power quality
For long-distance AC transmission, transmission capacity • Decrease system losses of distribution system
is limited due to the influence of voltage rise in the middle • Operate in combination of stepped-switchover capacitor
of transmission. Therefore, to reduce the voltage rise and bank to reduce the damage caused by frequent switching
maximally enlarge the transferred power, SVCs are normally of capacitor bank
installed in the midpoint or several points in the middle of
transmission line. Renewable Energy Generation
Weak systems such as small hydro-power plants or wind power
Additionally, a SVC system installed on the AC side of DC
plants often experience power oscillation problems. Installing a
converter station can provide sufficient reactive power with fast
SVC system at the interconnection point can efficiently stabilize
response and easy maintenance.
system voltage to an acceptable level and maximally prevent
Benefits the harmful impact caused by faults in the power grid.
• Regulate and stabilize system voltage. Benefits
• Increase static stability and transient stability of power
• Improve power factor by dynamic reactive power
system.
compensation
• Increase line transmission capacity.
• Eliminate harmonics
• Restrain po wer os c illat ion and s ub- s y nc hr o n o u s
• Eliminate power fluctuation and voltage flicker
resonance.
• Provide local reactive power, stabilize system voltage and
• Restrain transient overvoltage.
reduce transmission line losses

read more on www.nrelect.com 325


Industrial consumers compensation), or the sum of reactive power at the injected
Electronic rectifiers applied to electrolysis power supply and point is zero which means the power factor is equal to 1 (for
mill machines need large amount of reactive power. The use load var compensation).
of AC arc furnace usually comes with heavy harmonics and
large negative sequence current. Large amount of reactive
power demand and reactive power variation result in the
voltage fluctuation and flicker, which also reduces the operation
efficiency. SVC system can not only supply sufficient reactive
power, but also eliminate the harmonics generated by rectifiers
and prevent equipments from voltage fluctuation.

Benefits
• Increase power factor by dynamic reactive power
compensation.
• Eliminate voltage distortion caused by harmonics.
• Stabilize voltage and reduce voltage fluctuation and flicker.
• Balance three-phase load current and eliminate negative
sequence current.
• Increase operation safety of impact loading equipment and
its adjacent electrical equipment.

Figure 2. Static Var Compensator


Configuration
The PCS-9580 static var compensation system consists of static
var compensator and control & protection system which is used
- Step-down transformer
to protect capacitors and reactors in the valves.
If no third winding of a main transformer can be used, a step-
The static var compensator is composed of thyristor controlled down transformer is needed.
reactor (TCR), thyristor switched capacitor (TSC), thyristor
switched reactor (TSR), and Breaker Switched Capacitor (BSC). - Medium Voltage switchgear
The SVC can be considered as a dynamic reactive power Medium voltage switchgear can be installed indoor or
source. It supplies reactive power to grid or consume spare outdoor, including isolating switches, grounding switches and
reactive power from grid. Normally, the system can receive the transformers.
reactive power from a capacitor group, and the spare part can - Linear (Air-core) reactor
be consumed by an air-core shunt reactor. Air-core reactors are more stable and have good linear
performance. It is used to absorb or adjust the reactive power.
The current in the air-core reactor is controlled by a thyristor Usually the air-core reactor is connected with the thyristor valve
valve. The valve controls the fundamental current by changing in series in Δ connection and then connected to the power grid.
the firing angle, ensuring the voltage can be limited to an
acceptable range at the injected position(for power system var - Thyristor valve
Thyristor valves are the main control part in the SVC system.
The valve is composed of several series/parallel connected
thyristor and the auxiliary components. The thyristor is
controlled through optical fiber and it adopts water cooling as
the main cooling method.

- Capacitor/filtering banks
Capacitor/filtering banks can supply sufficient capacitive reactive
power to power grid and filter harmful harmonics. It is composed
of capacitors and other auxiliary components such as filtering
reactors and filtering resistors.

In practical, the capacitor/filtering banks are divided into several


sub banks and can be connected/disconnection to system by
breakers or other thyristor valves.

- Water cooling system


Water cooling system is necessary for thyristor valves which
have high operating voltage. The cooling system uses de-
ionized pure water for internal cooling and regular industrial
recycling water for external cooling.
Figure 3. Structure of Static Var Compensator

326 read more on www.nrelect.com


- Control and protection system
SVC operator control system, including operator workstation,
LAN and printers, realizes SVC remote control, monitoring and Thyristor Control Unit
event alarm functions in the control room.

• SVC control and protection equipment, including master


controller of SVC control and protection system, distributed Thyristors

field bus and distributed I/O etc. It needs to be noted


that the master controller for SVC control and protection
realizes all SVC control functions.
Heat Sink

• Microcomputer protection measurement and control


Figure 4. Valve Structure
equipment, including reactor protection, filter bank
protection, BSC protection.
connection to reactor, the hydraulic connection to water cooling
• Interface to primary main equipment and measuring system and the optic connection to control devices are installed
equipment, including valve trigger control unit (VCU), at site.
realizes communication with SVC control system as well as
control interface to valves; water cooling control interface • Electrical/Optic triggering system
realize the control of water cooling equipment; current and Electrical triggering system comprises two parts, the Valve
voltage measurement interface, breaker/switch interface Control Unit(VCU) in the control room and the Thyristor Control
etc. The specific configuration and functions are described Unit(TCU) in the valve.
in the subsequent chapters.

• Interface to other control systems such as substation The Control Pulse(CP) will be converted to optic Firing
monitoring system, including: one communication manager Pulse (FP) by VCU and finally converted to electric FP by
(protocol converter) is arranged to transmit SVC alarm TCU to trigger thyristor. If the thyristor is not forward biased
information, protection information, important status or damaged, the control system will issue an alarm or stop
information and operation parameters to substation operating according to the signal sent from TCU.
monitoring system or remote dispatch system and receive
control and status information from substation monitoring The optic triggering system is a new reliable technology which
system and remote dispatch system; receive time uses light to trigger thyristor. It integrates forward overvoltage
comparison signal of the substation main GPS clock. The protection components, and thyristor management units are
specific configuration and functions are further described in used instead of thyristor control units.
the subsequent chapters.
• Thyristor Break-over Voltage Protection
Thyristor can be damaged by large crossed forward voltage
if it is not conducting during the system operation. Thus it is
Functions and Features essential to force the thyristor to conduct before reaching the
break-over voltage. The break over diode(BOD) is usually
• Optimized system design used to protection thyristor from being damaged by forward
overvoltage. However, a series connected BOD can cause a
NR has introduced RTDS, analog simulation system and
large deviation in break-over voltage. To solve this problem,
EMTDC in the design processes to study system voltage,
NR invented the unique protection circuit integrated in thyristor
system stability, active and reactive power distribution and
valves. It reduces the break-over voltage deviation to the
restraint harmonics so as to optimize SVC system design.
minimum value, and the break-over voltage can be fixed
manually to adapt to different types of thyristor.
The optimized filter groups can filter large amount of harmful
harmonics, provide fundamental frequency reactive power
• Water Cooling System
and minimize dynamic active losses.
NR’s SVC system uses the industrial-class hermetic water
cooling system with de-ionized water to cool valves. This
- The customized SVC system can analyse system power
patented cooling radiator features low thermal resistance and
quality to check injected harmonic current and filter
low water resistance. With its high reliability characteristic, water
resonance.
cooling systems have been applied to many industrial areas
such like aviation, power generation and HVDC transmission.
- The most optimized regulation mode will be selected based
on the actual situation of each installation place to gain the
• Reliable protection and control system
most effective voltage/reactive power regulation.
The protection and control of Static Var Compensator uses the
reliable software and hardware platform of HVDC control and
• Thyristor valve
protection system. The high integrated software platform uses
NR’s Thyristor Controlled Reactor(TCR) has advantages of
graphic programming and test tools to realize different control
compacted structures, less area occupation and light weight,
functions. The universal hardware platform is equipped with
which make valve installations and maintenance work much
multi-functional modular to achieve data acquisition, control and
easier. Assembling of valve is completed in factory before
monitoring functions.
shipping to ease on-site installation. Only the electrical

read more on www.nrelect.com 327


PCS-9583
Static Synchronous Compensator

A static synchronous compensator(STATCOM) is a regulating • Suppressing of harmonics is effective even the capacity
device used on reactive AC power transmission in FACTS equipment is expanded.
application. It is based on a voltage-source converter and can • Filtering branch circuit can be removed.
act as either a source or sink of reactive AC power to a power
• Low voltage harmonics.
network. Large capacity inductors and capacitors are replaced
by high power electronics conductors. The STATCOM can • Small voltage aberration rate at interconnection point and
automatically generate inductive or capacitive power, and adjust small harmonic current injected to grid.
the amount of output reactive power considerding load property • The use of H bridge cascading STATCOM can greatly save
and system operation situations. land resource and bring significant economic benefits to
industrial end users.
NR’s STATCOM adopts multilevel modularization design
to solve the consistency problem of voltage stress for each NR's H bridge cascading STATCOM is composed of power
equipment in series connection arrangement. The use of units, reactors, starting units and control units. Control units
industrial grade components significantly reduces costs and provide the control of normal operation, running mode switching
improves device reliability. The multi-level output votlage has and data exchange with substation automation system.
low harmonic components, which can effectively reduce the
voltage distortion factor at interconnection point and decrease The H bridge cascading STATCOM provides the direct dynamic
the injecting harmonic current to grid. reactive power compensation for HV busbar. The compensation
is realized by the series cascading connection of full-controlled
The STATCOM is designed in H bridge cascading structure, converter bridges. The compensation characteristics are shown
bringing the following benefits to end users: in the following diagram.
• Low requirements of operation conditions to aviod complex
harmonic measurement.

Read more on the web


328 read more on www.nrelect.com www.nrelect.com
PCS-9590/9591
DC De-Icer

Ice coating caused by extremely cold climate can damage


transmission lines and lead to the power outage in partial
or entire network. To guarantee the safe operation of power
system in severe weather in winter, NR provides PCS-9590
fixed DC de-icer and PCS-9591 relocatable DC de-icer for
500kV, 220kV and 110kV transmission lines. The DC output
voltage is adjustable, and different DC short-circuit current
can be applied according to the cables’ diameter and length.
The device can be used as an SVC to quickly compensate
reactive power and improve quality of electric energy.

PCS-9590 Fixed DC De-Icer


The fixed DC de-icer is applicable to long transmission lines • The cooling system of relockable DC de-icer is composed of
with high voltage level. The power supply of PCS-9590 is indoor forced water cooling and outdoor forced air cooling to
normally fed by a 35kV AC bus. The PCS-9590 fixed DC de-icer cool converter valve banks.
includes:
• The phase segregated circuit breakers is used to select the
• The PCS-9590 has two standard commercial containers: one target AC line and realize balanced de-icer of AC lines.
is used to install of valve banks and water cooling system,
• The control and protection system provides supervision and
the other is equipped with phase segregated circuit breakers
protection functions for the whole DC de-icer device.
and control panels.

• One 3-winding converter transformer is used to facillitate


current commutation among valve banks.
Features
• The key component in the DC de-icer is the 12 pulsation
• The use of thyristor rectifiers can reduce the impact on
conversion valve banks which can convert the AC current to
power system during ice melting and ease the switch-over
DC current.
operations.
• The water cooling system is consisted of indoor forced water
• The DC de-icer device supports large current and large angle
cooling and outdoor forced air cooling components to cool
continuous stable operation. It is applicable to tranmission
converter valve banks.
lines with different conductor diameters and lengths.
• The phase segregated circuit breakers is used to select the
• The PCS-9590/9591 DC de-icer can adopt container type
target AC line and realize balanced de-icer of AC lines.
installation and valve hall installation, effectively saving the
• The control and protection system provides supervision and land resource, shortening the site construction period and
protection functions for the whole DC de-icer device. easing the equipement transportation.

• The device adopts reliable and compact structure with water-


cooling system and compact valve banks.
Relocatable DC De-Icer
• The PCS-9590/9591 is equipped with 6 phase seg circuit
The relocatable DC de-icer device is applicable to short lines breakers enabling the automatic switchover among various
with low voltage levels. Normally the power supply of device is ice melting modes and realizing the balanced ice melting for
fed by a 10kV AC bus. The PCS-9591 relockable DC de-icer AC lines.
includes:
• NR also provides the high performance control and protection
• The PCS-9591 has one standard commercial container to system for DC de-icing melting characteristics has been
install all equipments. developed and features and high reliability.
• The key component is a 6 pulsation conversion valve banks • Primary system of DC ice melting device requires only very
used to convert AC current to DC current. small number of operations to realize SVC function.

Read more on the web


www.nrelect.com read more on www.nrelect.com 329
PCS-9570
Fixed Series Compensator (FSC)

The fixed series compensator(FSC) plays an important role


in the intelligent network due to its effect on transmission
lines, especially those with long distance. It can improve
the transmission capacity of the transmission network and
achieve optimal power flow to optimize dispatching, reduce
losses and make full use of power supply at the minimum
generation cost. NR’s PCS-9570 series compensators can
offer complete FSC solutions. It consists of primary devices
including capacitor, metal oxide arrester, damping circuit,
spark gap, bypass switch, series compensator platform etc,
and the secondary devices such as electronic transformers,
FSC protection & control system etc.

The PCS-9570 series products are designed based on tens electronic transformers and the protection & control
of years' experences on the protection & control solutions system.
for tHVAC relay protection. The AC digital sampling based
• Embedded structure offering high integration
on electronic transformers effectively settles the interference
The UAPC platform developed by NR features good
problem on site during AC analog sampling of traditional series
performance, rapid processing and modular interface/card
compensators. The protection and control model based on
plug-ins and has been widely used in HVDC transmission
IEC61850 can implement sequence control of substation series
systems.
compensators to automatically switch-in or switch-over capacitor
banks with series compensators so as to optimize the power • Duplicated protection configuration
flows and improve transmission capacity in smart substations.
• Independent duplicated protection blocking circuits
The series products are mainly applicable to the capacitor series
compensators in the AC transmission lines of 66kV~1000kV. • Simple operation and easy maintenance
The traditional protection mode is applied to system from
operation interfaces to value settings to ease operation
and maintainance.
Features
• Electronic transformers and duplicated configuration of
• Safe and reliable primary system merging units (MU)
It is designed with safe and reliable coordination between The electronic transformers and duplicated configuration
the capacitor bank, MOV, spark gap, damping circuit, offer stronger anti-interference capability.

Protection and control system diagram for fixed series compensator

330 read more on www.nrelect.com


RENEWABLE ENERGY
INTERCONNECTION

PCS-9563
PV Grid-Interconnection system

PV grid-interconnection system refers to the system that


converts solar power to electric power and transmits to the
grid. It consists of solar array module, PV convergent cubicle,
PV grid-connection inverter, and grid-connection system.

NR introduces PV grid-interconnection technology and


provides integrated solution for inverters, substation
monitoring and power prediction, PV power stations
centralized monitoring and control. The grid-connection
inverter is the key equipment of PV grid-tie system.

PCS-9563 series PV grid-interconnection system consists - Auto start/stop


of advanced IGBT controlled inverter, protection & control The PCS-9563 PV grid-interconnection inverter is designed
equipments and I/O switchgear etc. The system power capacity with auto grid connection and manual control is not required.
portion is designed in modularized structure featuring easy The inverter automatically detects the DC/AC system data in
extension, convenient installation and maintenance, optimal standby mode and automatically shifts to ‘Run’ mode for grid
layout, and less land occupation. The system control portion is interconnection when the running conditions are fulfilled. It
based on the professional control & protection platform featuring tracks the PV array maximum peak power (MPPT) in real-time
abundant hardware resources, complete software functions, and maintains the maximum power output during running.
and flexible configuration of control/operation parameters, to
maximally meet the extension demand of on system flexibility
- Auto fault processing
and extensibility.
During grid-interconnection operation, the inverter detects the
self-operation condition and the status of PV array and AC grid
in real-time. Once any fault or abnormal condition is detected in
System function the PV power generating system, the inverter will stop running,
- Operating modes send out alarm signals and enter fault emergency stop mode.
The PCS-9563 has three working modes—Standby, Run and The detailed fault information will be displayed on the LCD of
Stop, two self-check statuses—Normal and Fault, several control devices. The inverter will continuously detect the system
running control modes—PQ control, Voltage Frequency control status in fault mode and automatically restore running after the
and Low voltage ride through (LVRT) etc, and several auto system fault is cleared for 5 minutes.
control logics—Auto run”, Auto stop, Fault emergency stop etc.

read more on www.nrelect.com 331


- Running functions • High-performance and reliable control devices
■ SCADA The control & protection devices features well performance,
The SCADA function acquires and processes the real-time high reliability and mature hardware/software technologies.
system operating data of the PV system, including battery DC The core controller is equipped with the most advanced
voltage, inverter running data etc, send out alarm and update floating controller which has advantages of high main
the automation system database. frequency, large memory capacity, and high computation and
control accuracy. The control system fully supports IEC61850
■ Soft grid-connection control and IEC60870-5-103 etc. The equipment uses integrated
The control system can accurately control the inverter output front panels and enclosed rack that it can protect against
voltage in real-time based on the detected grid voltage and dust and ensure the safe and reliable operation of control
eliminate dynamic/static error to realize impulse-free connection. system during the service life of PV power station.

■ Maximum Peak Power Tracking (MPPT) control • High power quality


The system can search the maximum peak power based on the The grid-connection power quality controlled by PCS-9563
collected battery physical data and control the real-time tracking is far higher than that defined in the relevant codes and
of inverter to achieve the maximum power utilization. standards. In the certified test by CGC-SOLAR, both the total
harmonic distortion of voltage (Uthd) and current (Ithd) are
■ Dynamic Var control smaller than 2%, the voltage on connected network is even
In case of voltage drop in the grid, the control system can smaller than 1% at rated power.
provide automatic reactive power compensation to maintain the
grid voltage based on the voltage dip and duration.
System transient voltage

■ Island detection Inverter phase A transient input current

The system can rapidly detect the appearance of island


condition and handle it according to the preset configuration.

■ Low voltage ride through (LVRT) operation


The PCS-9563 inverter can maintain grid-interconnection
operation and realize LVRT in case of low voltage fault in the
grid.

■ Power quality (PQ) control  


The system is designed with grid-interconnection power Figure. PV Inverter Output Waveform
optimization to ensure power quality.

• Complete and reliable protection functions


PCS-9563 system has inherent protection for IGBT modules
Features by detecting abnormal dv/dt and di/dt in IGBT and blocking
the triggering pulse instantly. As a result, it can ensure safe
• Product testing and certification and reliable operation or rapid and safe shutdown even in
The PCS-9563 inverter has passed the LVRT field test by severe environment.
SGEPRI and Qinghai Electric Power Research Institute in
Qinghai PV Power Station.

• High reliable and long-life system design


The primary/secondary components of the inverter have
good quality and long operation life. The component
selection, power design, and heat dissipation design are all
based on high altitude and extreme adverse conditions with
margin to ensure the reliable system operation and working
life. The inverter adopts modular design to ease installation
and maintenance, including IGBT module and other major
equipments. The large capacity IGBT modules are used
to reduce parallel connections and increase equipment
reliability. The optical triggering method has strong anti-
interference capability and the patented heat dissipation
scheme is employed to achieve high reliability and efficiency.

Read more on the web


332 read more on www.nrelect.com www.nrelect.com
PCS-9561
Doubly Fed Converter System

With the rapid development of computer science and


control technologies, the wind power technology has been
developing fast accordingly. The control mode has evolved
from simplex constant pitch stall control to full blade variable
pitch and variable speed control. At present, the doubly fed
converter system with variable speed constant frequency
control is widely used in wind generation market.

Operating principle System Configuration


Figure 1 shows the schematic structure of doubly fed converter.
The rotor is excited by two back-to-back connected VSC PWM - Cabinet Arrangement
converters (referred to as generator side converter and grid side The PCS-9561 doubly fed converter system is especially
converter respectively). The doubly PWM converters supply designed for doubly fed wind power turbines. It consists of grid
excitation current to rotor winding to realize the maximum interconnection/control cabinet (1200mm*800mm*2200mm,
capture of wind energy and the adjustment of stator reactor protection class is IP54), and power module cabinet
power output. When the turbine operates at a sub-synchronous (1200mm*800mm*2200mm, protection class is IP23).
speed, power is fed into the rotor and the grid side converter
runs as a rectifier while the rotor side converter runs as an • The grid interconnection/control cabinet includes two isolated
inverter, providing the excitation current to the turbine. When cabinets, which are control cabinet and grid interconnection
the turbine operates at super-synchronous speed, stator and cabinet. The control cabinet is composed of controller,
rotor can both feed energy to the grid. If the turbine operates in UPS, low voltage circuit breakers, protection devices and
synchronous status, the generator runs as a synchronous motor wiring terminals etc. The grid interconnection cabinet
and the converter system provides DC excitation to the rotor. incorporates distribution transformer, main circuit breaker,
grid interconnection contactor, grid side contactor, main fuse,
and pre-charging resistor etc.

• The power module cabinet is the main part to accomplish


current conversion. In addition to three power units at both
grid and generator side each (each such unit integrates IGBT,
drive board, radiator, DC capacitor, absorption capacity,
and temperature measuring resistor etc.), the cabinet also
includes laminated busbar, grid side reactor, bridge arm side
reactor, generator side reactor, grid side and generator side
filtering resistor and capacitor, large and small fans, and
heater etc.

The grid side converter and the generator side converter are - Primary part
controlled by two control units. The grid side control unit is used
to maintain DC busbar voltage stability and ensure high quality • The primary part of converter system consists of power
input current waveform and unit power factor. The generator modules (the integrated power unit composed of IGBT
side control unit is used to controls the rotor current torque and its drive, protection, and heat dissipation accessories
and the excitation components of doubly fed motor to adjust its etc.), filtering system, temperature control system, pre-
active power and reactive power output, and tracks active power charging system, low voltage ride through system, and power
order and reactive power order, so that the doubly fed motor distribution system etc.
can run on the optimum power curve of wind turbine to realize • The power module consists of three groups of grid side
the maximum capture of wind power. power units and 3 groups of generator side power units

Read more on the web


www.nrelect.com read more on www.nrelect.com 333
• Control the power factor by system power factor order (or
reactive power order) tracking issued by wind turbine control
function;

• Realize “zero” impulse grid interconnection control;

• Control high voltage and low voltage ride throught of


converter system;

• Restrain the injecting current harmonics to grid via harmonics


control strategy;

• Limit the low frequency rotor current harmonics via SVPWM


dead zone compensation strategy;

• Monitor system operating conditions and provide various


protection functions such as overcurrent protection, DC
overvoltage protection, DC undervoltage protection, excess
temperature protection, external abnormal voltage protection,
overtemperature protection, and motor overspeed protection
connected by laminated DC busbar. Each group of power etc.;
units integrates high power switches, air-cooling radiator, • Control the temperature and the humidity of cabinets;
and gate driving unit with protection and monitoring circuit
etc. The laminated structure can maximally reduce the stray • Communicate with main control of wind power turbine;
inductance in DC busbar so as to significantly restraint the • Provide friendly HMI to monitor converter system operating
voltage peak occured during turn-off of IGBT condition, accurately record operating conditions, and to
• The filtering system contains grid side LCL filter and provide maintenance and fault analysis interface.
generator side du/dt filter. The grid side LCL filter can
effectively filter high frequency harmonics flow from converter
to grid. The du/dt filter works with generator side choking
reactor to suppress voltage peak and fast transient voltage Performance
appeared on rotor insulation, thus effectively delay motor
insulation aging. • Fast response capability and high control precision;

• The temperature control system monitors temperature and • Complete fault recording function conformed to IEEE
humidity of key parts inside the cabinet. It controls the cabinet COMTRADE format;
internal temperature and humidity within an acceptable
• High reliable and flexible integrated protection system;
range through heating, air-cooling heat dissipation, and
dehumidifying.. • Grid interconnection control strategy based on self-
adaptive positioning of rotor can realize “zero” impulse grid
• The pre-charging system is used to raise the DC voltage
synchronization;
of DC capacitor to certain amplitude prior to the startup
of converter, thereby reducing the current impulse during • Photo-electric encoder which adopts software reset mode
converter startup to the maximum extent. can improve the accuracy and reliability of motor rotation
speed acquisition;
• The low voltage system adopts active crowbar circuit. In
case of operation fault, line fault, or rotor high voltage, the • High voltage and low voltage ride through control strategy are
low voltage system can protection the power semiconductor used to guarantee the converter fault ride through capability;
devices at motor side in order to achieve low voltage ride
• Harmonics suppression control strategy and dead zone
through. Thus the converter system can supply current to the
compensation strategy are adopted to effectively ensure the
grid even in the case of grid fault.
quality of power delivered from converter to grid;
• The power distribution system provides uninterrupted power
• Compatible with various industrial fieldbus communication
supply for each active device of converter.
interfaces, such as CANopen and Profibus.

• Identical IGBT converter bridge modules are connected in


- Control unit parallel, and installation and removal of each power module
is convenient.
The control unit is the brain of doubly fed converter system and
• Elaborately designed filtering system and harmonics
one of the key factors that decide converter performance. The
restraint control strategy ensure the superior quality of power
control unit mainly performs the following functions:
delivered into grid.
• Ensure that the converter system toqure, or the active • This product can withstand high/low temperature and high
output is able to follow orders from generator to realize the humidity. Inside the cabinets, temperature and humidity
maximum capture of wind power sensors, and heating and dehumidifying measures are
provided. All circuit boards are equipped with anti-corrosion
coating and all cabinets have very high protection class.

Read more on the web


334 read more on www.nrelect.com www.nrelect.com
STABILITY CONTROL SYSTEM

Power Stability Control System


Power Stability Control System (PSCS) is used to effectively
prevent and reduce the possibility of system oscillations.
Imbalance between loads and generations can result in
system frequency and voltage changes and could finally
lead to system collapse. Power stability control can quickly
restore system balance by load shedding or generator shut
down based on the preset control tactic, bringing voltage and
frequency back to an acceptable value, so as to minimize the
affected area and avoid cascading instability.

Architecture
Figure 1 shows a power stability control system composed of • Transmit data to Execution Stations & Master Stations
one master station, several sub-master stations and execution • Acquire data and drive control outputs
stations. Communications between master station and sub-
master stations are implemented by optical fibers. Up to 30 sub-
Execution Station:
stations can be connected to a master station. Each station has
one central unit and several bay units, which is called stability • Calculate local-scale control tactic tables
controller. • Transmit data to Sub-master Station
• Acquire data and execute tripping or close commands

The definitions of master station, sub-master stations and


execution stations are determined according to system actual
operation conditions. The master station may either be a
certain key power plant or a certain important substation, other
substations are sub-master stations, and other power plants are
execution stations.

Stability Controller
PCS-992 Stability Controllers are installed in substations/power
plants of the power gridis installed in dispatching centers to
Figure 1. The typical structure of power stability control system

Master Station
• Calculate system-scale control tactic tables
• Transmit data to Sub-master Stations & other Master
Stations
• Distribute tactic tables to Sub-master Stations (If online)

Sub-master Station:
• Calculate region-scale control tactic tables PCS-992 Stability Controller

Read more on the web


www.nrelect.com read more on www.nrelect.com 335
collect system operation information, power flow conditions, Bay units at master station
event records and data records from master and sub-master • Acquire and calculate data.
stations through communication channels, and sends control
• Discriminate lines (transformers and generators) operating
tactic table and setting value to stations. The communication
status.
channel is either fiber microwave or optic cable interface
• Discriminate faulty lines (transformers, generator units and
with 2M(64K) Ethernet using IEC 60870-5-103 or IEC 61850
busbar) and fault types.
protocol.
• Execute commands received from local bay unit.
• Implement stability control tactics.
• Perform control functions that are not related to system
Functions operation modes such as transformers or lines overload
discrimination.
Stability controller
• Detect the operation conditions of outgoing lines, Central unit at sub-master station
transformers and generators. • Communicate with central units in master station and
• Transmit status information from one station to another execution station.
station. • Receive discrimination results from local sub-master units.
• Automatically identify the on-line operation mode of grid. • Implement stability control tactics.
• Discriminate the fault types of outgoing lines, transformers
or busbar. Bay units at sub-master station
• Calculate the best control strategy using stability analysis • Acquire and calculate data.
according to power flow and fault type. • Discriminate lines (transformers and generators) operating
• Determine measurements that should be taken, e.g. status.
generators shutdown, load shedding, separating, • Discriminate faulty lines (transformers, generator units and
modulating of DC power, quickly reducing output of busbar) and fault types.
generators, etc.
• Execute commands received from local bay unit.
• Real-time control measures will be taken when the
• Implement stability control tactics.
incidents related to frequency or voltage stability, overload,
• Perform control functions that are not related to system
etc., which are independent of the network operation
operation modes such as transformers or lines overload
mode, occur in the grid.
discrimination.
• Select the units to be shutdown in a most reasonable way
according to pre-defined specific requirements.
Central unit at execution station
• Control commands, control values, etc. are transmitted to
• Communicate with host unit in sub-master station.
other stations to be performed via communication network.
• Receive discrimination results from local bay units.
• Control commands received from the master station or
• Implement stability control tactics.
other stations will be performed after local discriminations
and confirmations are made.
Bay units at execution station
• Remotely monitoring and remotely modify setting.
• Acquire and calculate data.
• GPS clock synchronization.
• Discriminate lines (transformers and generators) operating
• Self-checking, abnormality alarm, automatic display, and
status.
printing, etc.
• Discriminate faulty lines (transformers, generator units and
Central unit at master station busbar) and fault types.
• Execute commands received from local bay unit.
• Communicate with central units in other master stations.
• Receive discrimination results from local central units. • Implement stability control tactics.

• Discriminate system operation mode. • Perform control functions that are not related to system
operation modes such as transformers or lines overload
• Establish power transfer limits.
discrimination.
• Implement stability control tactics.

Read more on the web


336 read more on www.nrelect.com www.nrelect.com
PCS-993
Out-of-Step Controller

The PCS-993 out-of-step controller is used to sense an out-


of-step condition on a power system and to initiate tripping.
When out-of-step condition has been detected, the PCS-
993 will separate asynchronous areas at pre-set points to
maintain a balance between load and generation in each
separated area.

The device introduces an extensive functional library,


programmable LED, programable logic and configurable I/
O, supporting IEC 61850-8-1 MMS, GOOSE, IEC 61850-9-2
Sampling Value.

Features
• The controller is based on NR’s well established and proven
UAPC hardware platform with multi-processor architecture.
Functions The multi CPU technology supports parallel operating
simultaneously.
• Out-of-step discrimination.
- Quick stage of out-of-step. • The two independent data acquisition paths can prevent any
undesired trip caused by component failure. One works as a
- Slow stage of out-of-step.
fault detector and the other is designed for protection and its
• Protection zone restriction logic. Tripping outputs are supervised by the fault detector to
• Out-of-step protection.(78) prevent a mal-operation.
• VT circuit supervision (VTS) • Introducing measured impedance characteristic with perspic-
• CT circuit supervision (CTS) uous physical conception for out-of-step condition detection
• Voltage and current drift auto regulation. criterion.

• Self diagnostic. • Data measurement, protection calculation, logic discrimina-


tion, event recording and protection logic calculation are pro-
• GPS clock synchronization.
cessed within one sampling period.
• Event recorder including 1024 disturbance records, 1024
• Out-of-step discrimination for parallel lines.
binary events, 1024 supervision events and 1024 operating
logs • Fast tripping mode and slow tripping mode are provided for
different oscillation cycles.
• Disturbance recorder including 64 disturbance records
with waveforms (The file format of disturbance recorder is • The patented adaptive floating threshold is immune to sys-
compatible with international COMTRADE file.) tem unbalance and disturbance.

• Pilot communication schemes with fiber, carrier or other • The relay provides GPS clock synchronization, including
channels. second pulse, minute pulse and IRIG-B synchronization.

• 2 optional Ethernet ports with IEC 61850 protocol. • The relay is compatible with IEC 61850-8-1 MMS, GOOSE
and IEC 61850-9-2 Sampling Value and provides the
• 2 RS-485 communication rear ports with IEC 60870-5-103
independent interfaces for station bus and process bus
protocol.
respectively.
• 1 RS-485 communication rear ports for clock synchroniza-
tion.
• 1 RS-232 communication rear ports or RS-485 for printer.
• 1 RS-232 communication faceplate port for testing and set-
ting.

Read more on the web


www.nrelect.com read more on www.nrelect.com 337
Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Read more on the web


338 read more on www.nrelect.com www.nrelect.com
Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005
- Mechanical tests

Read more on the web


www.nrelect.com read more on www.nrelect.com 339
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


340 read more on www.nrelect.com www.nrelect.com
RCS-993
Out-of-Step Controller

The RCS-993 out-of-step controller presents an effective


way to prevent total system collapse caused by out-of-step of
interconnected power system.

When out-of-step condition has been detected, RCS-993


will give corresponding actions, including tripping associated
circuit breakers to separate the power system into two
or more smaller islands at pre-selected points, shutting
down proper generators, shedding appropriate loads or
triggering other related synchronizer preparing for the system
synchronism after the system separation.

Features
Functions • The device is built on DSP hardware platform with 14 bits
high accuracy A/D converter. DSP hardware performs data
• Out-of-step discrimination. acquisition, voltage, current and power-angle calculations,
and protection logic discrimination.
- Quick stage of out-of-step.
• Introducing measured impedance characteristic with
- Slow stage of out-of-step.
perspicuous physical conception for out-of-step condition
• Protection zone restriction detection criterion.
• Out-of-step protection.(78) • Flexible hardware/software configuration with modular
• VT circuit supervision (VTS) design structure.
• CT circuit supervision (CTS) • D a t a m e a s u r e m e n t , p r o t e c t i o n c a l c u l a t i o n , l o g i c
• Voltage and current drift auto regulation. discrimination, event recording and protection logic
calculation are processed within one sampling period.
• Self diagnostic test.
• Out-of-step discrimination for parallel lines.
• GPS clock synchronization.
• Fast tripping mode and slow tripping mode are provided for
• Fault Recorder.
different oscillation cycles.
• 128 event reports.
• The patented adaptive floating threshold is immune to
• High resolution oscillography of last 24 oscillograms. system unbalance and disturbance.
(Compatible with international COMTRADE format)
• The relay provides GPS clock synchronization, including
• Rear communication ports: 4 optional Ethernet ports or 2 RS- second pulse, minute pulse and IRIG-B synchronization.
485 conformed to IEC 60870-5-103 protocol, 1 RS-485 for
• The relay is compatible with IEC61850 and IEC 60870-5-
clock synchronization, 1 RS-232 or RS-485 for printer.
103.
• Front communication port: 1 RS-232 for testing and setting.

Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms

Read more on the web


www.nrelect.com read more on www.nrelect.com 341
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Read more on the web


342 read more on www.nrelect.com www.nrelect.com
Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV

Read more on the web


www.nrelect.com read more on www.nrelect.com 343
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


344 read more on www.nrelect.com www.nrelect.com
PCS-994
Frequency & Voltage Controller

The PCS-994 frequency-voltage controller is designed based


on innovative UAPC platform. It provides automatic load
shedding for double bus scheme in case of underfrequency
or undervoltage operation conditions. It sheds load or
separates grid islands under the conditions of underfrequency
and undervoltage.

The device introduces an extensive functional library,


programmable LED, programable logic and configurable I/
O, supporting IEC 61850-8-1 MMS, GOOSE, IEC 61850-9-2
Sampling Value.

• Disturbance recorder including 128 fault reports, and 24


oscillograms (The file format of disturbance recorder is
compatible with international COMTRADE file.).
• GPS clock synchronization - second pulse, minute pulse, RS-
485 difference level and IRIG-B synchronization.
Functions
Communication
Under-frequency Control Scheme • 2 optional Ethernet ports with IEC 61850 protocol.
• Four basic stages from stage 1 to stage 4 • 2 RS-485 communication rear ports with IEC 60870-5-103
• 2 special stage protocol.
• 2 accelerated stages • 1 RS-485 communication rear ports for clock synchroniza-
• Blocking element of df/dt tion.

• Blocking element of frequency abnormality • 1 RS-232 communication rear ports or RS-485 for printer.

• Blocking element of dead bus • 1 RS-232 communication faceplate port for testing and set-
ting.
• Rear communication ports: Ethernet (Optional) or 2 RS-485 with
IEC60870-5-103 protocol, 1 RS-485 with clock synchronization,
1 RS-232 or RS-485 with printer. Features
• Front communication port: 1 RS-232 for testing and setting.
• The RCS-994 can accelerate load shedding to prevent power
system collapse when the system voltage or the frequency
Under-voltage Control Scheme decreases sharply and it will bring voltage back to the
• 4 basic stages from stage 1 to stage 4 operation range afterward.
• 2 special stage
• The power swing blocking function based on the analysis of
• 2 accelerated stages
df/dt and du/dt can prevent mal-operation caused by short-
• Blocking element of du/dt circuit fault or abnormal conditions of voltage and frequency.
• Blocking element of voltage abnormality
• The patented adaptive floating threshold method is adopted,
which is insensitive to system unbalance and disturbance.
Assistant function
The measuring element can get both high security and high
• VT circuit failure detection logic speed simultaneously.
• Zero drift adjustment of sampling data
• The relay provides GPS clock synchronization, including
• Self diagnostic test. second pulse, minute pulse, and IRIG-B synchronization.
• Online diagnostics of hardware circuit.
• The relay is compatible with multiple protocols- IEC61850
• Event Recorder including 64 binary input change reports and 64 and IEC 60870-5-103. The RCS-901 provides networking
self-supervision reports. interface such as RS485, RS232 and Ethernet port.

Read more on the web


www.nrelect.com read more on www.nrelect.com 345
Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Read more on the web


346 read more on www.nrelect.com www.nrelect.com
Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

Read more on the web


www.nrelect.com read more on www.nrelect.com 347
- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


348 read more on www.nrelect.com www.nrelect.com
RCS-994
Frequency & Voltage Controller

RCS-994 is a frequency-voltage emergency controller used


on automatic load shedding for double bus scheme in case
of underfrequency or undervoltage operation conditions. It
sheds load or separates grid islands under the conditions
of underfrequency and undervoltage. The standard
configuration of RCS-994 can manage up to 22 on-load lines.

• Event Recorder including 64 binary input change reports and


64 self-supervision reports.
• Disturbance recorder including 128 fault reports, and 24
oscillograms (The file format of disturbance recorder is
compatible with international COMTRADE file.).
• GPS clock synchronization - second pulse, minute pulse, RS-
485 difference level and IRIG-B synchronization.

Communication
• 2 RS-485 communication rear ports conform to IEC 60870-5-
103 protocol
Functions • 1 RS-485 communication rear ports for clock synchronization
• 1 RS-232 or RS-485 (can be set by jumper) communication
Under-frequency Control Scheme rear ports for printer
• Four basic stages from stage 1 to stage 4
• 1 RS-232 communication faceplate port for testing and
• 2 special stage setting
• 2 accelerated stages • 2 optional Ethernet ports, IEC 61850, or IEC 60870-5-103
• Blocking element of df/dt over TCP/IP
• Blocking element of frequency abnormality
• Blocking element of dead bus
• Rear communication ports: Ethernet (Optional) or 2 RS-485 with Features
IEC60870-5-103 protocol, 1 RS-485 with clock synchronization,
• The RCS-994 can accelerate load shedding to prevent power
1 RS-232 or RS-485 with printer.
system collapse when the system voltage or the frequency
• Front communication port: 1 RS-232 for testing and setting. decreases sharply and it will bring voltage back to the
operation range afterward.
Under-voltage Control Scheme
• The power swing blocking function based on the analysis of
• 4 basic stages from stage 1 to stage 4
df/dt and du/dt can prevent mal-operation caused by short-
• 2 special stage circuit fault or abnormal conditions of voltage and frequency.
• 2 accelerated stages
• The patented adaptive floating threshold method is adopted,
• Blocking element of du/dt
which is insensitive to system unbalance and disturbance.
• Blocking element of voltage abnormality The measuring element can get both high security and high
speed simultaneously.
Assistant function
• The relay provides GPS clock synchronization, including
• VT circuit failure detection logic
second pulse, minute pulse, and IRIG-B synchronization.
• Zero drift adjustment of sampling data
• The relay is compatible with multiple protocols- IEC61850
• Self diagnostic test.
and IEC 60870-5-103. The RCS-901 provides networking
• Online diagnostics of hardware circuit. interface such as RS485, RS232 and Ethernet port.

Read more on the web


www.nrelect.com read more on www.nrelect.com 349
Technical data
Power Supply
Rated Voltage (Un) 24 Vdc, 30 Vdc, 48 Vdc, 64 Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 25 W
Burden
Operating condition < 55 W
Backup battery type ML2032, 3V, 65mAh

AC Current Inputs
Rated frequency 50Hz, 60Hz, ±10%
Phase rotation ABC
Rated Current (In) 1A 5A
Linear to (non-offset AC current) 30In 30In
continuously 3In 3In
for 10s 30In 30In
Thermal withstand capability
for 1s 100In 100In
for half a cycle 250In 250In
Burden <0.2VA/phase @ In < 0.5VA/phase @ In

AC Voltage Inputs
Standard Per IEC 60255-6:1998
Rated Voltage (Un) 100V/√3, 110V/√3 100V, 110V 200V
linear to 100 V 173 V 230V
Thermal continuously 120 V 120 V 200V
withstand 10s 200 V 200 V 350V
capability 1s 250 V 250 V 400V
Burden <0.2 VA/phase @Un <0.5 VA/phase @Un <2.5 VA/phase @Un

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)

Read more on the web


350 read more on www.nrelect.com www.nrelect.com
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Communication Interfaces
Communication medium Parameters
Interfaces for communicating with RTU/SCADA
Port number 2
Baud rate 4800bps~57600bps
Transmission distance < 1000m@4800bps
RS-485 (EIA) Electrical Maximal capacity 32
Twisted Pair Screened twisted pair cable
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type ST
Baud rate 4800bps~57600bps
Transmission standard 100Base-FX,
Transmission distance <1500m
RS-485 (EIA) Optical(Optional)
Optical Fiber Type Multi-mode Fiber
Wavelength 850/820nm
Fiber size 62.5/125μm (core DIA/cladding DIA)
Protocol IEC60870-5-103:1997
Safety level Isolation to ELV level
Port number 2
Connector type RJ-45
Transmission rate 100Mbits/s
Electrical Transmission standard 100Base-TX
Transmission distance < 100m
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Port number 2
Connector type SC
Ethernet
Transmission Rate 100Mbits/s
Transmission standard 100Base-FX
Transmission distance < 1500m
Optical(optional) Optical Fiber Type Multi-mode or single-mode
853/1310nm for multi-mode
Wavelength
1310/1550nm for single-mode
Fiber size 62.5/125μm (core DIA/claddingDIA)
Protocol IEC60870-5-103:1997 or IEC61850
Safety level Isolation to ELV level
Rear interface connecting local HMI with personal computer via RCSPC software
Port number 1
Local HMI communication
Application
Download program of protection relay
RS-232 (EIA)
Baud rate 4800bps~57600bps
Connector type 9 pin D-type female connector
Safety level Isolation to ELV level
Interfaces connecting printer
Port number 1
Baud rate 4800 ~ 38400bps
RS-232 (EIA)
Printer type EPSON® LQ-300K
Safety level Isolation to ELV level
Interfaces for clock synchronization
Port number 1
Transmission distance < 500m
RS-485 (EIA) Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Read more on the web


www.nrelect.com read more on www.nrelect.com 351
Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I
- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


352 read more on www.nrelect.com www.nrelect.com
MEASUREMENT & RECORDING

PCS-996A
Phasor Measurement Unit

The PCS-996A Phasor Measurement Unit (PMU) relies on a


GPS time signal to provide extremely accurate time-stamping
of the power system information. The measured vector
quantities are sent to control center to provide a basis for
monitoring, protecting and controlling power networks.
PMU in Substation/Power Plant

PMUs are installed in substations and power plants as a


part of Wide Area Measurement System (WAMS) and Power
Stability Control System (PSCS). It can improve system
economic operation and enhance power stability against any
severe disturbances. PMUs installed in different locations are
synchronized by a GPS clock. If the GPS source is lost, an
internal high-precise clock source will be used instead.

The PCS-996A is hosted on the advanced UAPC multi-


processor platform, fully complying IEEE Std C37.118-2005,
IEC 60870-5-103 and IEC 61850 standard to ensure the
openness communication and enable easy integration into
any system.

Functions • GPS synchronization: Pulse per second, IRIG-B or SNTP


message
PCS-996A PMU for Substation
• Time-tagged current/ voltage phasor measurement
Phasor Data Concentrator
• RMS value, frequency, df/dt measurement
• Collect Data from PMUs
• Distrubance & fault data record
• Transmit Data to Remote Control Center
• Synchronized phasor via GPS time signal
• Store Data in Non-Volatile Memeory as Backup
• Up to 24 voltage/24 current inputs, 36 BIs & 4 optional BOs
• Connect with up to 6 PMUs
• Dual communictions to PDC: 1*Point-to-Point optical fiber &
• Industrial Embedded Computer Platform
1*10/100BaseTx or 10/100BaseFx
- Without rotating component, such as harddisk, cooling fan

• Communication to PMUs
PCS-996B PMU for Generation
- Ponit-to-point optical fiber for real-time phasor data
• Time-tagged current/ voltage phasor measurement
- 10/100MBaseTx/Fx for transient record data
• RMS value, frequency, df/dt measurement - IEC 60044-8 & IEC 61850 / IEC 608705-103
• Distrubance & fault data record
• Communication to Remote Control Center
• Synchronized phasor via GPS time signal - 4 *10/100MBaseTx or 10/100BaseFx ports
• Measurement of generator source voltage, rotor angle - Via SONET/SDH network
- IEEE 1344 & IEEE C37.118 protocol
• Measurement of excitation system voltage, current & speed
• Up to 24 voltage/24 current inputs, 36 BIs & 4 optional BOs • Data Backup
• Dual communictions to PDC: 1*Point-to-Point optical fiber & - Up to 128 GB Non-Volatile memory
1*10/100BaseTx or 10/100BaseFx - Up to 14 days data

Read more on the web


www.nrelect.com read more on www.nrelect.com 353
Features
• Protective relay technology and high EMC performance.

• Sampling rate: 24 to 96 samples/cycle(1.2kHz to 4.8kHz for


50Hz).

• Data transfer rate: 10 to 100 phasors/second.

• Compatible with IEEE 1344 & IEEE C37.118 standard.

• Uninterrrupted synchrophasor measurement during fault and


disturbance.

• Frequency tracking for accurate measurement.

• Dual communication channels to avoid network congestion


during inquiring fault and disturbance data.

- Real-time data via point-to-point optical using IEC 60044-8

- Disturbance & Fault record data via LAN using IEC 61850
or IEC 60870-5-103
Figure1. Typically Architecture for Integration in WAMS

Integration to WAMS
The PCS-996 fully supports communications to Wide Area
Measurement System (WAMS) based on international
protocols(IEEE Std C37.118-2005, IEC 60870-5-103 and
IEC 61850). The measured vector quantities are transmitted
from PCS-996A to WAMS via communication network and
assembled for advanced supervision and analysis. It allows
direct comparison of phasor from various locations in the power
system.

Integration to PSCS
The measured vector quantities can be transmitted from PCS-
996A to Power Stability Control System (PSCS) for the stability
control. In case of imbalance between generation and load
or severe disturbance evolving power oscillations, PSCS cab
take fast and reliable emergency actions, such as generator
shut-down, load-shedding, to ensure the system stability for
defending power system against blackouts.
Figure 2. Typically Architecture for Integration in PSCS

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz

354 read more on www.nrelect.com


Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

read more on www.nrelect.com 355


Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Temperature range -5°C ~+55°C -5°C ~+55°C
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level
Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV

Read more on the web


356 read more on www.nrelect.com www.nrelect.com
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


www.nrelect.com read more on www.nrelect.com 357
PCS-9013
DFR Management System

The Disturbance Fault Recording Management System(DFR-


Manager) is designed to manage Disturbance & Fault
Recorders(DFRs) in the entire power system. It provides
real-time monitoring and waveform analysis based on the
information collected from each DFR. Operators in local
substations are capable of modifying settings, viewing alarm
information and analyzing waveforms. Brief information is
available for retrieving on request. Short message (SMS) and
Email reminding functions are integrated in this management
system.

The DFR-MS is c om pos ed of m as ter s tation h u m a n - • Alarming: it checks the fault report, events and waveforms
machine interface(MHMI) and local station human-machine received from DRs
interface(LHMI). Functions of MHMI and LHMI mainly include:
• Analysis function: DFR-MS can call waveform files and
perform analysis using dedicated analysis tool;
Master station human-machine interface(MHMI)
• Parameters configuration: all parameters of DR in the whole • Remote control: the management system supports remote
system can be configured and uploaded to devices; control, remote time synchronization and remote reset.

• Documents management: operators can search and call


waveform files according to waveform list;

• State monitoring: it can monitor network status and check Features


measured data to learn the operating conditions of DR;
• Authority configuration and verification functions are
• Setting management: DFR-MS can modify settings of any provided. When logging on management interface, users
DR within the scope of control; can choose to browse DR status in local region. Users with
WEB authority is entitled to accept or reject short message or
• Remote control: it supports remote control, remote time
email.
synchronization and remote reset.
• The default view path for MHMI model is: Region → station
• Alarm processing: it provides real-time monitoring of received
→ device → unit, the default view path for LHMI model is:
event and fault reports, and sends post-processing to DR via
Device → unit → subordinate station. Switching between
emails and short messages;
these two models is available.
• Waveform analysis: it provides waveform analysis using
• Disturbance recorders are usually configured and tested on-
dedicated analysis tools;
site at local substation. The configuration information will
• WEB inquiry: operators can inquire DR parameters and be collected at master stations and stored synchronously in
waveform files through internet. All information can be database.
downloaded to a local PC for further analysis.

local station human-machine interface(LHMI)


• Parameters configuration: all parameters of DR in local
substations can be configured and uploaded to devices;

Read more on the web


358 read more on www.nrelect.com www.nrelect.com
PCS-996R
Disturbance Fault Recorder

The PCS-996R disturbance & fault recorder(DFR) is an


multifunctional data acquisition system designed to address
the data recording requirements of substations. It captures
the curves of monitored quantities and aligns the values of
different supervised objects to build disturbance records. The
PCS-996R helps users to simplify disturbance analysis by
The DFR System can be configured at the customers’ request combining the discrete records in different protective relays.
as a centralized or decentralized architecture. It can operate
in regional networks and wide area networks under IEC 61850 The disturbance & fault recording system can be centralized
protocol, FTP and IEC 60870-5-103 based on LAN. Up to 1500 or distributed architecture based on customers’ requests.
sets of DFRs can be integrated and managed in this system. Up to 1500 sets of DFRs can be integrated and managed
DFR can also be applied to a substation separately with a local in this system. DFRs can also be applied to a substation
computer and HMI software. GOOSE function is integrated to independently with a local computer and HMI software. The
receive information from process bus. protocol of communication network can be IEC 61850, FTP
and IEC 60870-5-103 based on LAN. GOOSE function is
integrated to receive information from process bus.
Standard format
NR's DFRs are equipped with 48 analog channels and 60 binary
channels in a mountable enclosure. It can be synchronized by
an external time source.

Recording
• Slow recording @1 ~ 50Hz , for long term power quality
• Triggered recording @ 9600Hz, for short term transient monitoring
process.
• Extract recording @ 9600Hz, extract fault channels from all
• Continuous recording @1200Hz, for middle term dynamic channels of triggered records automatically, for information
process efficiency.

Figure 1. Typical application of the PCS-996R in a wide-area DFR system

Read more on the web


www.nrelect.com read more on www.nrelect.com 359
Functions - Absolute value of sudden change of zero sequence over
limit
Recording Functions - Power swing
• Initiating recording by AC voltage
• Initiating recording based on binary input
- Phase voltage over upper limit
• Continuous recording (24hours uninterrupted recording)
- Phase voltage under lower limit
- Sudden increase/decrease of phase voltage over limit Auxiliary Function
- Negative sequence voltage over upper limit • Self diagnostic test
- Zero sequence voltage over upper limit
• Loss of DC power supply alarm
- Absolute value of sudden change of zero-sequence over
limit • Hardware circuit online detection

- Frequency over upper limit • Support IRIG-B time synchronization


- Frequency under lower limit
Communications
- Absolute value of df/dt over limit
• 1 RJ45 Ethernet port complied with IEC60870-5-103 and
• Initiating recording based on AC current out-of-limit IEC61850 protocol
- Phase current over upper limit
• 1 RS-485 serial port used for GPS time synchronization
- Absolute value of sudden change of phase current over
limit • 1 RS-232 serial port used to test and configure device

- Negative sequence over upper limit • 1 Ethernet interface used for FTP service of continuous
- Zero sequence over upper limit recording and real-time waveform display

• Two fiber Ethernet ports which support IEC60870-5-103


and IEC61850 protocol (available for PCS-996R)

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Read more on the web


360 read more on www.nrelect.com www.nrelect.com
Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class : IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm

Read more on the web


www.nrelect.com read more on www.nrelect.com 361
Temperature range -5°C ~+55°C -5°C ~+55°C
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


362 read more on www.nrelect.com www.nrelect.com
PCS-996S
Disturbance Fault Recorder

The PCS-996S disturbance & fault recorders are especially


designed for the monitoring and recording of electrical
quantities for smart substations. Digital signals are collected
by merging units and transmitted to PCS-996S for data
Functions comparison and information storage. GOOSE module and
Sampled Value module are equipment for communication
Recording Functions
with intelligent control devices and merging units based on
• Initiating recording by AC voltage
IEC 61850-9-2 protocol.
- Positive sequence voltage over upper limit
- Positive sequence voltage under lower limit
- Absolute value of sudden change of phase voltage over
limit • Initiating recording based on binary input
- Absolute value of sudden change of zero-sequence over • Continuous recording (24hours uninterrupted recording)
limit
- Negative sequence voltage over upper limit Auxiliary Function
- Zero sequence voltage over upper limit • Self diagnostic test
- Frequency over upper limit • Loss of DC power supply alarm
- Frequency under lower limit
• Hardware circuit online detection
- Absolute value of df/dt over limit
• Support IRIG-B time synchronization
• Initiating recording based on AC current out-of-limit
- Phase current over upper limit Communications
- Absolute value of sudden change of phase current over • 1 RJ45 Ethernet port complied with IEC60870-5-103 and
limit IEC61850 protocol
- Negative sequence over upper limit
• 1 RS-485 serial port used for GPS time synchronization
- Zero sequence over upper limit
• 1 RS-232 serial port used to test and configure device
- Absolute value of sudden change of zero sequence over
limit • 1 Ethernet interface used for FTP service of continuous
- Power swing recording and real-time waveform display

Figure 2. Typical application of the PCS-996R in a smart substation

Read more on the web


www.nrelect.com read more on www.nrelect.com 363
Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Read more on the web


364 read more on www.nrelect.com www.nrelect.com
Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Temperature range -5°C ~+55°C -5°C ~+55°C
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

Read more on the web


www.nrelect.com read more on www.nrelect.com 365
- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


366 read more on www.nrelect.com www.nrelect.com
PCS-986
Disturbance Fault Recorder

The PCS-986 disturbance & fault recorders are designed


to record electricity parameter variations for generator-
transformer units and operation processes of protection

Functions & control devices in power plants. The device adopts unit
architecture that hardware and software can be flexibly
Recording Functions assembled and upgraded in the future.
• Initiating recording based on AC voltage
- Phase voltage sudden change
- Positive-sequence voltage sudden change
• Initiating recording based on binary input
- Zero-sequence voltage sudden change
• Initiating recording based on system oscillation
• Initiating recording based on AC current
• Initiating recording manually
- Phases voltage sudden change
- Positive-sequence voltage sudden change • Initiating recording remotely
- Zero-sequence voltage sudden change • Continuous recording (24hours uninterrupted recording)
• Initiating recording based on AC voltage out-of-limit
Auxiliary Function
• Initiating recording based on AC current out-of-limit • Self diagnostic test
• Initiating recording based on positive-sequence and • Loss of DC power supply alarm
negative-sequence component out-of-limit
• Hardware circuit online detection
• Initiating recording based on DC sudden change or DC
component out-of-limit • Support IRIG-B time synchronization

• Initiating recording based on frequency out-of-limit and


Communications
sudden change
• 1 RJ45 Ethernet port complied with IEC60870-5-103 and
• Initiating recording based on third harmonic out-of-limit IEC61850 protocol

• Initiating recording based on over-excitation out-of-limit • 1 RS-485 serial port used for GPS time synchronization

• Initiating recording based on reverse power out-of-limit • 1 RS-232 serial port used to test and configure device

• Initiating recording based on low-frequency overcurrent or • 1 Ethernet interface used for FTP service of continuous
zero-sequence voltage for startup/shutdown recording and real-time waveform display

• Initiating recording based on differential current of main


transformer, step-down transformer, generator or excitation
transformer

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
<30W (for conventional substation application)
Quiescent condition
<35W (for smart substation application)
Burden
<35W (for conventional substation application)
Operating condition
<40W (for smart substation application)

Read more on the web


www.nrelect.com read more on www.nrelect.com 367
Analog Current
Standard IEC 60255-27:2005
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated Current (In) 1A 5A
Linear to 0.05In ~ 40In
continuously 4In
for 10s 30In
Thermal withstand capability
for 1s 200In
for half a cycle 250In
Burden <0.2VA/phase < 0.25VA/phase

Analog voltage
Standard IEC 60255-6, IEC60288
Phase rotation ABC
Nominal frequency (fn) 50Hz, 60Hz
Nominal range fn±5Hz
Rated phase-to-phase voltage (Un) 100~130V 200V (Broken delta for residual voltage)
linear to 1~170V 1~233V
continuously 200V 220V
Thermal withstand capability 10s 260V 380V
1s 300V 420V
Burden < 0.20VA/phase @Un < 0.8VA/phase@Un

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage 24V 30V 48V 110V 125V 220V 250V
Rated current 1.2mA 1.5mA 2.4mA 1.1mA 1.25mA 2.2mA 2.5mA
Pickup voltage 13V~17V 17V~21V 26V~34V 60.5V~77V 60.5V~77V 121V~154V 121V~154V
Dropout voltage 90% of pickup voltage
Maximum permissive voltage 300Vdc
Withstand 2000VAC, 2800VDC(continuously)
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contact
Output mode Potential free contact
5A@250V AC 8A@380V AC
Continuous carry
5A@250V DC 8A@250V DC
Pickup time <8ms <10ms
Drop-off time <5ms (not include delay time by software) <8ms
6A@3s 10A@3s
Short duration current [email protected] [email protected]
[email protected] [email protected]
0.6A@48VDC 0.7A@48VDC
Breaking capacity (L/R=40ms) 0.2A@110VDC 0.3A@110VDC
0.1A@220VDC 0.2A@220VDC
380V AC 380V AC
Maximal working voltage
250V DC 250V DC
Test voltage across open contact 1000V RMS for 1minute 1200V RMS for 1 minute

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009

Read more on the web


368 read more on www.nrelect.com www.nrelect.com
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Communication Port
- EIA-485 Port
Baud rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Protocol IEC 60870-5-103:1997
Maximal capacity 32
Transmission distance <500m
Safety level Isolation to ELV level
Twisted pair Screened twisted pair cable

- Ethernet Port
Connector type RJ-45
Transmission rate 100Mbits/s
Transmission standard 10Base-T/100Base-TX
Transmission distance <100m
Protocol IEC 60870-5-103:1997 or IEC 61850
Safety level Isolation to ELV level

- Optical Fiber Port


Characteristic Plastic optical fiber Glass optical fiber
Terminal BFOC/2.5 (OR F-SMA) BFOC/2.5 (OR F-SMA)
Fibre size Step-index 980/1000 μm Graded-index 62.5/125 μm
Transmission distance Up to 40m Up to 1000m
Wave length 660nm 820nm~860nm
Temperature range -5°C ~+55°C -5°C ~+55°C
Transmission power Min. -7dBm Min. -16dBm
Minimum receiving power Min. -20dBm Min. -24dBm
System reserve Min +3dB Min +3dB

- Print Port
Type RS-232
Baud Rate 4.8kbit/s, 9.6kbit/s, 19.2kbit/s, 38.4kbit/s, 57.6kbit/s, 115.2kbit/s
Printer type EPSON® 300K printer
Safety level Isolation to ELV level

- Clock Synchronization Port


Type RS-485
Transmission distance <500m
Maximal capacity 32
Timing standard PPS, IRIG-B
Safety level Isolation to ELV level

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

Read more on the web


www.nrelect.com read more on www.nrelect.com 369
- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

370 read more on www.nrelect.com


ENERGY MANAGEMENT

PCS-9000
Energy Management System

PCS-9000 energy management system (EMS) is a computer- database management, coordinated man-machine interactive
aided tool used by operators of electric utility grids to monitor, interface, transmission of network information, interprocess
control, and optimize the performance of generation and/or communication, system management and alarm service etc.
transmission system. It adopts advanced network management, It can be transplanted and distributed on various hardware
object-oriented database and visualized cross-platform platform structures. Each application function constructed on
technology. the basis of PCS-9000 ASP is a building block that can be
integrated with other functions or implemented separately.
The system operates based on the latest IEC61970 standard,
providing a unified application platform for large scale energy
management of power enterprises. The PCS-9000 energy Electric power applications based on ASP
management system includes SCADA, Automatic Generation PCS-9000 Energy Management System provides full
Control(AGC), Power Advanced Software(PAS), Dispatching series power system applications to improve power system
Training Simulator(DTS), Automatic Voltage Control(AVC), management level. Its modular functions can be easily
Wide Area Measurement System(WAMS), OMS(Operation customized to meet the demands of control centers. In addition,
the PCS-9000 energy management system is extensible for
Management System) and WEB applications. It can be
function upgrade to satisfy user demands in the future.
easily integrated with other systems conformed to IEC61970
standard to protect the existing investments and reduce internal PCS-9000 system typical configuration scheme is shown in
information and function redundancy. Figure 1. PCS-9000 series products include:

• PCS-9000 Energy Management System

Structure • PCS-9000 Tele-Meter Reading System


• PCS-9000 Distribution Management System
Unified Application Supporting Platform (ASP) • PCS-9000 Operation Management System
PCS-9000 unified application supporting platform provides • PCS-9013 DFR Management System
powerful and universal services for distributed real-time
• PCS-9010 Digital Relays Remote Monitoring System

Figure 1. PCS-9000 system configuration scheme

read more on www.nrelect.com 371


• State estimation
• Dispatcher power flow
• Short-term load forecasting
• Steady state security analysis
• Short-circuit current calculation
• Dynamic stability assessment
• Optimal power flow

Dispatcher Training Simulator (DTS)


• Trainer subsystem
Figure 2. PCS-9000 EMS Module
• Power system simulation subsystem
• Control center simulation subsystem

Wide Area Measurement System(WAMS)


Functions • Data acquisition
• Data processing
Supervisory Control and Data Acquisition (SCADA)
• Alarm processing
• Data processing
• Data calculation
• Reserved capacity supervision
• Statistic calculation
• Control and regulation
• Control and regulation
• Sequence of event
• Network topology analysis
• Data calculation and statistics assessment
• Network topology dynamic coloring
• Trend curves
• Grid operation dynamic supervision
• Post disturbance review
• Auxiliary service analysis
• Event and alarm
• Power system model and parameter check
• Historical functions
• Post-disturbance review and simulation curve check
• Blocking and unblocking
• Labeling
• Topological coloring
Features
• Shift takeover management
• Clock synchronization • Innovative EMS system developed based on IEC61970
• SCADA database modeling standard
From unified application supporting platform to all power
• Manual data input
system applications, the management system is fully
• Network-Oriented function complied with IEC61970 standard.

Automatic Generation Control(AGC) • Integrated Graphic Modeling Technology Based on


IEC61970 CIM Model
• Load frequency control The Integrative Graphic Modeling Technology based on
• Economic Dispatch IEC61970 CIM model enables operators to draw substation
• LFC performance Monitor diagram and build network model fast.
• Reserve Monitor
• Hybrid Platform System
• Generation scheduling The use of cross-platform visualized technology and
• Transaction scheduling operating system transparent middleware provides system
• Super short-term load forecasting with better portability to build a hybrid platform system with
multiple hardware platforms.
• Unit test and sampling
• Unit commitment • Easy Expandability and Progressive Upgrading
• Hydro scheduling & hydro-thermal coordination PCS-9000 system frame is easily expandable for its
distributed modularization structure with UIB based on P/S.

Power Application Software(PAS)


• Network modeling
• Network topology

372 read more on www.nrelect.com


PCS-9002
Distribution Management System

The PCS-9002 is a state-of-the-art Distribution Management • SCADA: It is responsible for data acquisition, monitoring
System(DMS) operating on IEC61970 and IEC61968 standard. and control, and issuing system alarms when abnormal
It features complete automation of dispatching, distribution, conditions occur.
operation and service through the management of distribution • DA: It's responsible for fault detection, fault locating, fault
network, thereby ensuring the reliable and economical operation clearance and recovery in the distribution network.
of distribution system.
• AM/FM/GIS: Automated Mapping/Facilities Management/
Geographic Information Management.
The PCS-9002 uses SCADA data as the base data and
adopts Geographic Information System(GIS) as the display • DJM: It manages the day to day management of power
platform, and integrates SCADA/DA, GIS and the Distribution distribution and provides complete automation of the work
Job Management System. It scientifically manages the process.
whole distribution system and enhances economic benefits • DPAS: It realizes the load forecasting, reactive power
by introducing the concept of integration of real-time data optimization, load flow calculation and power loss
acquisition, distribution automation and management, calculation.
and places emphasis on the application of distribution job
management and related system data interactions. The self-
developed and customized flexible working-flow management Features
platform substantially improves management efficiency, and
ensures that the system functions are tightly combined with the
• Comply with IEC 61970 and IEC 61968 standard
internal working flows of the power enterprise.
It adopts open architecture and integrated application
platform to meet the expandable requirements of distribution
functions.
System Structure
• Hardware-independent
The distribution management functions consist of SCADA, DA, The application of hardware-independent technology and
GIS, power distribution job management, video monitoring, middleware technology provides a convenient combination of
distribution power application software and so on. different computer platforms on which to build a distribution
management system.

Typical System Structure Diagram

read more on www.nrelect.com 373


• Maintenance of integrated component and graph library Distribution Job Management(DJM) system is the core
The integrated component and graph library and the unified subsystem of DMS, it plays an important part in realizing the
management system can quickly generate all sorts of graphs complete automation of the dispatch management system of the
and equipment property, as well as measurement models distribution network. The DJM is closely connected to realtime
and network topology models for SCADA, DPAS and DTS system, assisting dispatchers to complete the verification
applications. of various forms such as the management of equipment
inspection application sheet and system dispatching planning
• Intellectualized Distribution Automation (DA) management. It realizes the full automation of distribution
The DA technology enables fast and versatile real-time management by introducing the job management system so as
topology calculation based on the inner relations between to ease the work strength and improve the quality of work.
devices by automatically searching the current network
topology and the system real-time information. The system
can automatically identify any fault according to the topology
relation and obtain the most optimum operation solution and
PCS Series Distribution
perform quick fault clearance and system recovery.
Sub-station &Terminal Units
NR’s PCS series distribution sub-station and terminal units
can provide a complete set of automation solutions for
SCADA switching station, ring main unit, distribution station, pole-
type switch and transformers. It is designed to realize SCADA
The SCADA subsystem is the foundation of DMS system. real-time monitoring, distribution automation, power quality
It consists of data acquisition, data processing, control and management and switch-in and retransmission functions of
regulation, event and alarm, real-time calculation, network intelligent equipments. It gives sufficient consideration to severe
topology, history data, authority management and system operation environment impact, and has advantages of high
monitoring management. SCADA subsystem provides the real- reliability and stability, good electromagnetic capability, low
time monitoring and control of distribution equipments such as power consumption, wide working temperature range, shock-
feeders, circuit breakers, ring main units, switching stations and proof, water-proof, lightning-proof and easy maintenance. To
distribution transformers. improve the correctness of fault discrimination and enhance
the efficiency of fault isolation, the devices introduce optical
Ethernet ring communication network with high communication
Distribution Automation(DA) speed and transverse communication capability. The distribution
network terminal units can easily form an Ethernet ring network
The distribution automation system targets for fault detection, using optical fibers without any optical transceiver, leading to
positioning, fault clearance and system recovery. On the basis simplified maintenance work and enhanced communication
of tripping/closing event, protection operation and fault detection reliability.
information captured by SCADA, the distribution automation
system provides dispatchers with real-time fault analysis and
effective system outage recovery strategyto achieve rapid
Basic Functions
restoration and reduce system losses to a minimum value.
• Distribution Network Sub-station
As a sub-station of distribution network, the main functions
of PCS-9720A/B are to transmit the information between
Geographic Information System (GIS) terminals and master station, and provide distribution
automation in area. PCS-9720A is single-unit and PCS-
The distribution network system can display and manage
9720B is duplicated-unit.
information following the geographic distribution due to the
geography information support provided by the GIS system. • Distribution Network Communication Device
With this support, the distribution management system can The PCS-9882 is an industrial grade switch customized
display the real-time information of electric equipments and for power industry applications. It is normally used as the
represent the distribution graphs against a background setting main switch for optical Ethernet ring network to realize the
of geographic images. The integration of graphics management management and self-recovery of distribution communication
and data management enables dispatchers to intuitively network.
understand the space dispersion of the distribution network and
its equipments from all aspects. • Distribution Network Terminal Unit
Distribution network terminal units can be classified in four
categories, which are applicable to switching station, ring
main unit, pole-type switch and transformer.
Distribution Management System (DMS)
Distribution management system is a comprehensive
application system targeting for the realization of universal
system functions, including distribution network dispatching,
manufacturing and management services.

374 read more on www.nrelect.com


HVDC & VSC-Based HVDC

PCS-9550
HVDC Control & Protection System

The control and protection system is the key to the overall


performance of HVDC transmission system. It guarantees
safe and steady system operation, provides flexible operating
modes and accurate control effects, helps to clear fault and
assists in system recovery during system disturbances.

A well-designed control and protection system can maximally Control and Protection
exert the advantages of HVDC transmission technology in the
following aspects: System Structure
• Long distance bulk power transmission
A complete PCS-9550 HVDC control and protection system can
• Underground or underwater cables transmission be divided into the following sub-systems:
• Asynchronous interconnection of AC system
• Offshore transmission Interface with remote control center (e.g. state dispatching
center, provincial dispatching center and remote central control,)
• Multi-terminal systems
This sub-system consists of telecontrol workstations and
• Power delivery to large urban areas
Remote Terminal Units(RTUs) for point-to-point communication
with remote control centers.
NR's PCS-9550 HVDC control and protection system provides
steady, reliable, and efficient control and protection for various
types of HVDC transmission systems of different voltage levels. Operator control system
It is applicable to: Operator control system is so called SCADA system. It
• Classic UHVDC and HVDC transmission project consists of station LAN, operator workstations(OWS), engineer
workstations(EWS), SER terminals, system servers, station
• VSC-based HVDC transmission project
clock and etc. The operator control system is used as the
man-machine interface during HVDC operation which has the
The PCS-9550 HVDC control and protection system makes full
following functions:
use of its advantages and brings the biggest convenience to
new and retrofit HVDC transmission projects.

Figure 1. Control of HVDC Figure 2. Protection of HVDC

read more on www.nrelect.com 375


• Receiving and executing operation orders come from HVDC control and protection system supports connection to
operators or dispatch center. electronic measuring device to receive digital measuring signals
• Monitoring and processing failure information or via optical fiber.
abnormal operation status.
• Event sequence record and event alarm within the whole
station. - Hierarchical and distributed structure
• Synchronization and time calibration for all sub-systems HVDC control and protection system is designed in distributed
within the station structure with object-oriented principle. Each cell is responsible
• Parameter adjustment for DC control system for monitoring and control of equipments in one physical
• History data documentation or logical area. The design of each cell aims at mutual
independency to achieve minimum information exchange
• Emergency stopping of AC and DC systems
between different cells, and to eliminate the influence of fault in
• Management of converter station document and one cell on the normal operation of others.
programs.
• Fundamental training functions. Communications between distributed cells are based on
standard fieldbus or Ethernet via fiber cable, featuring excellent
real-time property, strong interference immunity and good
AC/DC station control system
stability and reliability.
AC/DC station control system consists of main computers and
distributed I/O. The main functions of this system are: The whole HVDC control and protection system is built in
• Sequence control of the equipment in AC and DC hierarchical structure which is divided into station level and
switchyard. equipment level.

• Execute trip commands initiated by protections.


Station level equipments include SCADA system equipments
• Connect and disconnect filters upon the orders from pole
and equipment level equipments include control and protection
control system.
units, I/O interface and distributed field bus. The station level
• Interlock and equipment level are connected via redundant SCADA
• Collect and manage the alarm signals of main/auxiliary LAN network, while the control and protection units and its I/O
equipment interface are connected through optical fieldbus.

In hardware realization, the DC station control is assembled


with the pole control system. - Redundancy
DC control system
The design of HVDC control and protection system aims at
DC control system implement the control of bipolar, pole and
100% availability and the whole system is built in redundant
converter unit. It consists of main control computers, distributed
structure. The reliable and complete duplicate design ensures
field buses and distributed I/O. The redundant system
that the normal operation of HVDC system can be immune to
configuration is adopted for each pole to achieve the following
any single failure.
functions:

• Generate control pulse for converter valve For the redundant control system, one system is active and the
• Maintain the synchronization between control pulse and other is on hot standby. System self-supervision and automatic
commutation voltage switch-over functions are used to ensure that the relative
healthy system is active. Operators may also manually select
• Keep interval equal between control pulses
the system operating state.
• Deblock/block converter valve with smooth and stable
startup/shutdown
• Regulate trigger angle of converter valves within the - Performance and Features
designed range to satisfy the ordered amount of power/
current. • Fully digitalization - all complex control and protection
• Adjust converter transformer tap changers according to functions are realized by software precisely
the operation status of AC and DC system • Open-ended - based on well-proved and common
• Implement sequence control of HVDC system industrial standards
• High reliability
DC protection system • High integration level
DC protection system ensures the safe operation of whole • Easy to cooperate with converters in various techniques
HVDC system. It includes DC protection(PPR), DC filter • Visual programming and debugging tools with cross-
protection(DFP), converter transformer protection(CTP) and AC platform capability
filter protection(AFP).
• High-performance distributed system with the fastest
interrupt response time of 25us;

Read more on the web


376 read more on www.nrelect.com www.nrelect.com
• Efficient heat dissipation system without rolling fans; - Features
• High-accuracy measuring system with synchronous
• Multilevel technology with low switching frequency and low
sampling technology;
operating losses;
• Optical-media-based fieldbus of high interference immunity,
• Well low voltage ride-through capability;
less use of cables;
• Applicable to high voltage and large capacity engineering
• Systematic electromagnetic shielding design, high
projects of different voltage levels. High flexibility suitable
interference immunity;
for flexible investment and construction in phase;
• All parts in the system are in redundant design, including I/
• Less harmonic components and less land resource
O devices;
occupation;
• Self-supervision function and fast switch-over in 2ms;
• Independent, fast and continuous adjustment of active and
• Flexible configuration of protection, easy to realize reactive power,
duplicate, redundant or two-out-of-three configurations; • Improving AC power angle stability, generating capacitive
• Compatible with IEC 61970 standard and fully supports reactive power and absorbing inductive reactive power;
IEC 61970 CIM graphic-model-database integration • Providing power to passive power network without
technology; supporting many standard communication commutating power supply;
protocols and the connection to equipments using different • Well black start capability;
communication protocols (IEC61850, IEC60870-5-101,
• Fast current reverse capability and no need of
IEC60870-5-102, IEC60870-5-103, IEC60870-5-104,
communications between converting stations;
IEC60870-6 (TASE 2)).
• Easy to form a multi-terminal HVDC power system;
• Abundant events with characteristic easy to distinguish.
Dynamic link can directly indicate the variable in visual • Capable of providing dynamic reactive power for AC power
program tool and is easy for fault tracing; grid.

• Independent harmonic supervision system;


• Independent 2M tele-communication channel for protection
system; - Applications
• Telecontrol system can be chosen between UNIX and
• Connecting renewable energy generations to power grids,
embedded unit system;
such as wind farm, tidal power station and PV power
generation;
• Connecting asynchronous grids to save investment;
VSC-Based HVDC • Supplying power to remote regions to reduce transmission
line maintenance and improve power quality;
The VSC-based HVDC transmission is a newly developed
• Providing power to separated electrical island and offshore
technology based on the control of voltage source converter,
oil & gas platform;
such as IGBT, to achieve high efficient power transmission and
• Suitable for multi-terminal HVDC transmission;
supply dynamic reactive power to interconnected HVAC power
grid. As one of the key technologies in smart grid construction, • Connecting to weak infeed network;
the VSC-based HVDC transmission has advantages of fast • Supplying power to city center HVDC network.
response, well controllability, flexible operation modes, strong
anti-interference capability and improvement of low voltage ride-
through capability. Compared to classic HVDC transmission,
this new technology can reduced system short circuit current
and supply power to passive power grid. It is an effective way to
prevent large area blackout and realize power transmission to
separated electrical island. The VSC-based HVDC transmission
can be applied to connect asynchronous grid, connect wind
farm to power grids and city center infeed.

NR’s total solution to VSC-based HVDC includes protection and


control system, DC electronic CT/VT and valve banks.

Read more on the web


www.nrelect.com read more on www.nrelect.com 377
PCS-9250
DC Electronic Transformer

NR provides DC ECT, EVT and filter imbalance ECT for both


classic and VSC-based HVDC transmission projects. The DC
electronic transformers have advantages of small size, light
weight, no ferromagnetic resonance problem.

DC electronic CT
DC electronic CT is used in HVDC converter station to convert module etc, and thus it has good temperature stability and
the DC current and supply the signals to control and protection well performance on EMC;
devices. The DC electronic current transformer is composed • The air-core coil is wounded in equalized turns in reverse
of converter, air-core coil, remote-end module, optical insulator
directions, which has well performance on external field
and merging unit. The digital outputs of DC electronic CT is
interference;
transmitted by optical fibers.
• The optical fiber composite insulator (optical insulator) has
advantages of high reliability and small volume which make
- Features the CT easy for transportation and installation;

• The product solves the problems caused by high operating • The remote-end is powered by laser. The laser power can
temperature, component fault and abnormal optical be adjusted in real-time according to the operating situation
interface; of remote-end module;

• The current divider adopts the unique symmetrical wiring • The remote-end module has two independent analog
technology to eliminate the influence of external magnetic sampling circuits to perform duplicated sampling, real-time
interference on the output signals; comparison and verification, and self-check functions;

• It has high measurement accuracy (Class 0.2) and fast • The remote-end modules are extensible, and can be flexibly
response time(step response pickup time < 125us); combined with merging units to meet various application
demands of DC control & protection system;
• The product structure can eliminate the radiation problem of
squirrel-cage current divider and its impact on remote-end • The merging unit is operating based on IEC60044-8 or
TDM bus. It has good compatibility and system integration
capability;

• The DC electronic CT is equipped with complete self-


monitoring function to perform operation monitoring and fault
maintenance.

DC Electronic Voltage Transformer

DC electronic VT is used to convert and transmit DC voltage


signals to control and protection devices in the converter station.
The precise resistor voltage divider is used to convert DC
voltage based on equipotential shielding technology. The use
of shunt capacitor voltage divider can realize equalized voltage
distribution and ensure its frequency characteristics. The remote-
  (a) (b) end module locally collects and transmits signals via optical
cables. The composite insulator is used to achieve reliable
Figure 1. (a) Suspension DC ECT (b) Suspension DC ECT
insulation.

Read more on the web


378 read more on www.nrelect.com www.nrelect.com
- Features • It has good frequency characteristics and the measurement
error is smaller than 0.5% when the frequency is in the
• The unique secondary RC voltage divider network enables range of 50Hz~1500Hz;
the independent operation of each remote-end modules,
• LPCT is used to convert the primary current. The primary
which solves the problem that the remote-end modules
conductor adopts feed-through type that it can ensure the
operation may be affected by the failure of single remote-
measurement accuracy and withstand big dynamic/thermal
end module;
stable current (thermal stable current: 0.35kA; thermal stable
• The RC voltage divider uses solid medium (oil-free and current: 34kA);
gas-free) for internal insulation. The insulation medium
• The remote-end modules are extensible, and can be flexibly
is specially processed that it can ensure well insulation
combined with merging units to meet various application
capability and PD level;
demands of DC control & protection system;
• The DC electronic VT adopts large-power precision HV
• The optical fiber composite insulator (optical insulator) has
resistor with metallic film as voltage divider resistor which
advantages of large insulation margin, simple insulation
measurement accuracy can reach Class 0.2;
structure, small volume, light weight and is easy for
• The HV side and LV side of capacitance divider are designed transportation and installation; The product is designed
with the same time constant, and thus the transformer has in suspension structure and the whole weight is smaller
good frequency characteristics and transient characteristics than 65kg, which can better meet the demands of onsite
as well as rapid response (step response pickup time < installation;
125us);
• The remote-end is powered by laser. The laser power can
• The remote-end is powered by laser. The laser power can be adjusted in real-time according to the operating situation
be adjusted in real-time according to the operating situation of remote-end module;
of remote-end module;
• The remote-end module has two independent analog
• The remote-end module has two independent analog sampling circuits to perform duplicated sampling, real-time
sampling circuits to perform duplicated sampling, real-time comparison and verification, and self-check functions;
comparison and verification, and self-check functions;
• The remote-end modules are extensible, and can be flexibly
• The remote-end modules are extensible, and can be flexibly combined with merging units to meet various application
combined with merging units to meet various application demands of DC control & protection system;
demands of DC control & protection system;
• The merging unit is operating based on IEC60044-8 or
• The merging unit is operating based on IEC60044-8 or TDM bus. It has good compatibility and system integration
TDM bus. It has good compatibility and system integration capability;
capability;
• The DC electronic CT is equipped with complete self-
• The DC electronic CT is equipped with complete self- monitoring function to perform operation monitoring and fault
monitoring function to perform operation monitoring and fault maintenance.
maintenancex.

DC filter Imbalance electronic current


transformer

PCS-9250 series DC filter imbalance electronic CT uses the low


power CT (LPCT) to convert primary current to digital signals.
It is composed of LPCTs, remote-end modules, fiber optic
insulators and merging units. The output signals of LPCT are
processed by the remote-end module and transmitted via optical
fibers.

- Features

• The product has high measurement accuracy and large


dynamic range. The CT measurement error is smaller than
0.5% with the current is between 5% In ~ 1500% In;
Figure 2. DC Filter Imbalance Electronic Current Transformer

Read more on the web


www.nrelect.com read more on www.nrelect.com 379
COMMUNICATIONS

MUX-2M/MUX-64
Interface Unit

MUX-2M and MUX-64 relay digital signal interface units are MUX-2M and MUX-64 can be installed in communication rooms
communication interfaces between RCS-900 series current near digital multiplexer communication devices. It connects with
differential protection relays, RCS-900 series permissive the multiplexer communication device via 75Ω or 120Ω coaxial
teleprotection relays, and RCS-900 series power system cable and connects with a protection relay by optical fiber.
stability control relays. Connections between MUX and relays
are implemented by optical fibers. MUX-2M and MUX-64 also
can be connected to multiplexers through electrical interface
with 2048kbit/s or 64kbit/s bit rate.

Technical data
Power Supply
Auxiliary Voltage -48V DC (0V grounded)
Operating Range -32VDC~63VDC
Nominal Burden 10W

Interface Specifications
Device MUX-64 MUX-2MC

Bit rate 256 kBauds 2048kbit/s ± 50ppm


Pair(s) in each direction One symmetric pair One coaxial pair
Test load impedance 120 ohms resistiv 75 ohms resistive
Nominal peak voltage of a mark (pulse) 1.0 V 2.37 V
Peak voltage of a space (no pulse) 0 V ± 0.10 V 0 ± 0.237 V
Nominal pulse width 3.9 us 244 ns
Ratio of the amplitudes of positive and negative
0.95 to 1.05 0.95 to 1.05
pulses at the centre of the pulse interval
Ratio of the widths of positive and negative
0.95 to 1.05 0.95 to 1.05
pulses at the nominal half amplitude
Maximum peak-to-peak jitter at an output port Refer to 5.1/G.823
Coaxial connector (female,L9) 1.5/5.6 Straight Jack For PCB, Female
Coaxial connector (male,L9) 1.5/5.6 Right Angle Plug Crimp, Male
Coaxial cable SYV-75-2
Transmission distance twisted wire<50m (between MUX-64 to Coaxial cable<50m; fiber cable≤30Km
PCM);
fiber cable≤30Km (between relay to MUX-
64)

Read more on the web


380 read more on www.nrelect.com www.nrelect.com
Optical-fiber Connector Specifications
Optical-fiber connector FC-PC connector
Transmission medium 9/125µm single mode fiber cable
Emission power -15.0±2.0dBm
Receiving sensitivity -33.0±2.0dBm
Recommended light-transfer distance ≤30Km
Recommended electrical-transfer distance ≤20m

Mechanical Specifications
Dimensions 482.6 mm (W) x 44.4 mm (H) x 229mm (G)
Enclosure Protection Per IEC60259:2001
IP40 for front panel

Read more on the web


www.nrelect.com read more on www.nrelect.com 381
PCS-912/913
Power Line Carrier Transceiver

PCS-912/913 power line carrier transceiver uses transmission • Wide working scope with margin of 4dB~36dB.
lines as the channel medium to transmit blocking protection
• Operation of receiving circuit is immune to CPU failure. Thus
signals over long distances. Normally, it starts to send signals
the device mal-operation can be avoided since the blocking
only if it receives initiating commands from protection devices.
signals sent from offside transceiver will not be lost.
Thus it can be used with high voltage line protection to form the
high frequency blocking protection for 110kV~500kV system. • The interface module supports 24Vdc, 110Vdc and 220Vdc
binary inputs according to practical requirements.

Features • Program commissioning and field program upgrading can


be performed with the EIA RS-232 standard commissioning
interface and dedicated commission software.
• DSP+FPGA architecture is adopted to ensure the real-time
data processing. • The device supports local printing and GPS clock
synchronization.
• Direct digital synthesis (DDS) technology is used to produce
precise carrier frequency signals. The transmitting frequency • Extensible interface supporting communications via CAN and
is monitored by internal high accurate frequency estimation RS-485 interfaces.
to guarantee its accuracy.

• Specially designed inverter switch power supply has


advantages of small size, high conversion efficiency, wide
margin and stable output voltage.

Technical data
Power Supply
Standard IEC 60255-11:2008
Voltage Range 88 to 300 Vdc or 88 to 264 Vac
Permissible AC ripple voltage ≤15% of the nominal auxiliary voltage
Quiescent condition <30W
Burden
Operating condition <55W

Binary Inputs
Standard IEC 60255-1:2009
Rated voltage (Un) 24V
Rated current 1.2mA
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permissive voltage 120%Un
Withstand 2000VAC
Other Electrical Specifications
Operating frequency range 40kHz ~ 400kHz
Center operating frequency (42 + 4n) kHz recommended, n=0,1...89
Transmission frequency error <10Hz
Estimated frequency error <10Hz

Read more on the web


382 read more on www.nrelect.com www.nrelect.com
Bandwidth (B) 4kHz
M i n i m u m f r e q u e n c y d i ff e r e n c e b e t w e e n t w o In-phase ≥ 3B
paralleled PLC transceivers Adjacent Phase ≥ 0B
Receiving operating bandwidth <1kHz
Input/output impedance under rated operating
75 Ω
frequency
Return loss > 10dB
Residual level in quiescent condition < -30dBv
Rated transmission level 40dBm/31dBv(10W)
Receiving pickup level -5 ~ +5 dBv
Backlash level < 1dB
Pickup time delay (contact) 3ms
Signal transmission time(Back to back)
Drop-off time delay (contact) 5ms

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6mm×177.0mm×291.0mm
Mounting Flush mounted
Trepanning dimensions (W×H) 450.0mm×179.0mm, M6 screw
Housing color Silver grey
Protection class
Standard IEC 60255-1:2009
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20
Pollution degree 2

Ambient Temperature and Humidity Range


Standard IEC 60255-1:2009
Operating temperature -40°C to +70°C Note: The operating temperature of LCD is -20°C ~ +70°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible
Altitude <3000m

Type test
- Environmental tests
Dry cold test Per IEC60068-2-1:2007
Dry heat test Per IEC60068-2-2:2007
Damp heat test, cyclic Per IEC60068-2-30:2005

- Mechanical tests
Vibration Per IEC 60255-21-1:1988 Class I
Shock and bump Per IEC 60255-21-2:1988 Class I

- Electrical tests
Standard IEC 60255-27:2005
Dielectric tests Test voltage 2kV, 50Hz, 1min
Standard IEC 60255-5:2000
Impulse voltage tests Test voltage 5kV
Overvoltage category III
Insulation resistance measurements Isolation resistance >100MΩ@500VDC

- Electromagnetic Compatibility
Per IEC 60255-22-1:2007
1MHz burst disturbance test Common mode: class III 2.5kV
Differential mode: class III 1.0kV
Per IEC60255-22-2:2008 class IV
Electrostatic discharge test For contact discharge: 8kV
For air discharge: 15kV
Per IEC 60255-22-3:2007 class III
Frequency sweep
Radiated amplitude-modulated
10V/m (rms), f=80…1000MHz
Radio frequency interference tests Spot frequency
Radiated amplitude-modulated
10V/m (rms), f=80MHz/160MHz/450MHz/900MHz
Radiated pulse-modulated
10V/m (rms), f=900MHz

Read more on the web


www.nrelect.com read more on www.nrelect.com 383
Per IEC 60255-22-4:2008
Fast transient disturbance tests Power supply, I/O, Earth: class IV, 4kV, 2.5kHz, 5/50ns
Communication terminals: class IV, 2kV, 5kHz, 5/50ns
Per IEC 60255-22-5:2008
Power supply, AC input, I/O port: class IV, 1.2/50us
Surge immunity test Common mode: 4kV
Differential mode: 2kV
Per IEC 60255-22-6:2001
Conducted RF Electromagnetic Disturbance
Power supply, AC, I/O, Comm. Terminal: Class III, 10Vrms, 150 kHz~80MHz
Per IEC 61000-4-8:2001
Power Frequency Magnetic Field Immunity
class V, 100A/m for 1min, 1000A/m for 3s
Per IEC 61000-4-9:2001
Pulse Magnetic Field Immunity
class V, 6.4/16μs, 1000A/m for 3s
IEC 61000-4-10:2001
Damped oscillatory magnetic field immunity
class V, 100kHz & 1MHz–100A/m
IEC60255-11: 2008
Auxiliary power supply performance Voltage dips: Up to 300ms for dips to 40% of rated voltage without reset
Voltage short interruptions: 100ms for interruption without rebooting

Read more on the web


384 read more on www.nrelect.com www.nrelect.com
ACCESSORIES

CJX/CZX
Interposing Relay Set

CJX/CZX-12R/CZX-22R interposing relay sets are used


with protective relays or control devices to trip and close
circuit breakers. It provides status contacts of related circuit
breakers.

Functions CJX interposing relay set has 14 independent module slots.


Device functions can be configured flexibly upon requests.
• Phase-segregated tripping output So far, NR provides 6 CJX types based on module functions,
• Phase-segregated reclosing output which are control relays of three-phase circuit breaker with
one or two trip coil(s), seal-in relays, voltage switchover
• Manual opening output
relays with or without latch, lockout relays, contacts
• Remote opening output multiplication relays and voltage paralleling relays.
• Manual closing output
• Accelerated tripping output CZX-12R consists of 2 groups of phase-segregated tripping
circuits and 1 group of phase-segregated closing circuits. It
• Anti-pump
can be applied to circuit breakers with dual tripping circuit
• LOCKOUT relays in single-busbar, double-busbar, triple-busbar or quadruple-
• Tripping circuit supervision busbar system configurations.
• Breaker status supervision
CZX-22R has 2 groups of phase-segregated tripping outputs,
• DC power supply supervision
1 group of phase-segregated closing outputs and accelerated
• DC power supply supervision tripping circuits for manual closing. It can be applied to circuit
• Repeated tripping prevention circuit breaker in one-and-a-half (3/2) breaker and four third (4/3)
• Tripping and reclosing signal breaker system configurations.

• Operation blocked by abnormal pressure


• Reclosing blocked by low pressure
• Closing blocked by low pressure
• Tripping blocked by low pressure
• AC voltage switching circuit and heating, improve humidity proof and increase device
• Tripping coil supervision operation safety.
• Spare relays • Jumpers are adopted to adjust the seal-in current of current
seal-in circuit.

• Tripping coil failure monitoring is provided.


Features • Plug-in modularized structure without internal wire connection
• In AC voltage switchover circuit, the voltage switchover on the rear panel is used to enhance device reliability and
relay can maintain the original output when DC power interchangeability.
supply is lost so as to avoid the loss of protection AC
• For SCADA or RTU application, CZX-12R and CZX-22R can
voltage.
provide the contact of KKJ relay (post closed position relay)
• The device uses completely sealed and high-resistance during remote opening or closing of circuit breaker according
relay with small power to decrease power consumption to user’s requirement.

Read more on the web


www.nrelect.com read more on www.nrelect.com 385
Technical data
Power Supply
Rated Voltage (Un) 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008
Per IEC 60255-11:2008
Voltage dips and voltage short interruptions
20ms for interruption without de-energizing, dips 60% of Un without reset up to 100ms
Quiescent condition < 40 W
Burden
Operating condition < 70 W

Binary Inputs
Rated Voltage (Un) 110VDC 125VDC 220VDC 250VDC
Pickup voltage 70%Un
Dropout voltage 55%Un
Maximum permitted voltage 150V 150V 300V 300V
Withstand 2000Vac
Resolving time for logic input <1ms

Binary Outputs
Item Tripping contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Making Capacity >1000W at L/R=40ms
Continuous carry 8A 5A
0.4A resistive 0.2A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.05A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 5ms/10ms 10ms/15ms
Dropout time (Typ/Max) 4ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations minimum 100,000 operations minimum
Durability
unloaded contact 10,000,000 operations minimum 10,000,000 operations minimum

Mechanical Specifications
Enclosure dimensions (W×H×D) 482.6×177×291 (unit: mm)
Trepanning dimensions (W×H) 450×179 (unit: mm), M6 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001
Front side IP40, up to IP51 (Flush mounted)
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV

Read more on the web


386 read more on www.nrelect.com www.nrelect.com
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C

Read more on the web


www.nrelect.com read more on www.nrelect.com 387
NR-0500
Operating Relay

NR0500 series auxiliary relays are of various functions mainly


used with main protection and control device in modular
design. Each relay type is designed with specific function.

Each relay is independent from each other with high


configurability and extensibility. Relay types are continuously
developed in order to meet the requirement of various
Type Applications
applications.
NR0551 Trip circuit supervision with current operated relay
NR0552 Phase segregated trip circuit supervision
NR0556 Current operated auxiliary relay (3 elements)
NR0557 Current operated auxiliary relay (6 elements)
NR0561 Bistable switching relay
NR0562 Monostable switching relay Features
NR0566 Electrical reset auxiliary relay
Electrical reset auxiliary element with internal operating • Types of relay of dedicated function are available and can
NR0571
coil supervision (high burden)
be flexible combined to meet with requirement of various
Self reset auxiliary relay with electrical reset LED indicator
NR0572 applications
(high burden)
• Completely-sealed, high-resistance and small power
consumption relays are used, power consumption and
Functions heat dissipation are greatly reduced and moisture proof is
improved, hence the security of relay is increased.
• Trip circuit supervision • Adaptive mounting modes, the relay modules can be
• Lockout function accommodated in a casing installed on a panel as a relay
device
• Tripping relay function
• Repeat relay function (voltage operated or current operated) • High burden of the relay for tripping or closing circuit breaker
has strong interference withstand capability
• AC voltage switching function
• AC voltage coupling function • More spare relays can be provided and flexible applied

Technical data
Power Supply
Rated Voltage (Un) 110Vdc, 125Vdc, 220Vdc, 250Vdc
Variation (80% ~ 120%)Un
Ripple in the DC auxiliary voltage Max 15% of the DC value. Per IEC 60255-11:2008

Binary Inputs
Rated Voltage 110VDC 125VDC 220VDC 250VDC
Pickup voltage 55% ~ 70%Un
Dropoff voltage > 10% Un
Maximum continuous voltage
132V 150V 264V 300V
withstand
Insulation withstand 2000Vac

Binary Outputs
Item Output contact Signal contacts
Output model potential free contact
Max system voltage 250VAC/DC
Test voltage across open contact 1000VAC RMS for 1 minute
Read more on the web
388 read more on www.nrelect.com www.nrelect.com
Continuous carry 8A 8A
0.4A resistive 0.4A resistive
Breaking capacity at 250Vdc
0.2A inductive(L/R=40ms) 0.2A inductive(L/R=40ms)
Short duration current 50A for 200ms 50A for 200ms
Pickup time(Typ/Max) 10ms/15ms 10ms/15ms
Drop off time (Typ/Max) 8ms/10ms 8ms/10ms
Bounce time 1ms 1ms
loaded contact 100,000 operations 100,000 operations
Durability
unloaded contact 10,000,000 operations 10,000,000 operations

Mechanical Specifications
Enclosure dimensions (W×H×D) 35×177×189 (unit: mm)
Trepanning dimensions (W×H) 37×179 (unit: mm), M3 screw
Mounting Way Flush mounted
Housing material Aluminum
Housing color Silver grey
Protection class per IEC60529:2001
Front side IP51
Other sides IP30
Rear side, connection terminals IP20

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Relative humidity 5%~95%, without condensation

Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

- Mechanical tests
Vibration IEC60255-21-1:1988, Class I
Shock and bump IEC60255-21-2:1988, Class I

- Electrical tests
Dielectric tests IEC60255-5:2000, test voltage: 2kV, 50Hz, 1min
Impulse voltage tests IEC60255-5:2000, test voltage: 5kV, unipolar impulses, waveform 1.2/50μs, source energy 0.5J
Insulation measurement IEC60255-5:2000, insulation resistance >100MΩ, 500Vdc

- Environmental tests
Dry heat test IEC60068-2-2:2007, Test Bd for 16 hours at +55°C
Dry cold test IEC60068-2-1:2007, Test Ad for 16 hours at -25°C
IEC60068-2-30:2005, Test Db for two (12+12 hours) cycles, 95%RH,
Damp heat test, cyclic
low temperature +25°C, high temperature +55°C
Read more on the web
www.nrelect.com read more on www.nrelect.com 389
RCS-9662
Auxiliary Relay Set

The RCS-9662 auxiliary relay set is used in substations


for VT voltage paralleling and switching over. One to four
independent voltage parallel and/or voltage switchover
modules can be equipped based on the on site situation.

According to the different combinations of voltage parallel Type Paralleling module Switching
modules and switchover modules, five types of RCS-9662 are 9662A 4 0
defined as listed in the table below. configuration and busbar 9662B 0 4
voltage transformers. AC voltage switchover circuit is equipped 9662C 2 2
for application to substation with double busbar configuration 9662D 3 1
and busbar voltage transformers. 9662E 1 3

One unit comprises 4 independent paralleled and/or switch


plug-in modules. According to different combination of these
two modules, 5 types of RCS-9662 can be provided then:

Technical data
Power Supply
Standard IEC 60255-11:2008
Auxiliary Voltage 250V, 220 V, 125V, 110 V,
Voltage Range -20%, +15%
Burden Quiescent condition <20W

Mechanical Specifications
Dimensions 150.4 mm (W) x 226.8 mm (D) x 296mm (H)
Flush Type Mounting Cutout Flush Type Mounting Cutout
Enclosure Protection Per IEC60259:2001
IP40 for front panel

Performance
Pickup Voltage of Relay 55%-65% nominal voltage

Capacity of Output Contacts


Item Signal contact Other auxiliary relay contact
Making and continuous carry 8A 5A
Breaking capacity at 220Vdc 0.3 A, L/R < 40 ms 0.3 A, L/R < 40 ms

Atmospheric Environment
Standard IEC60255-6:1988
Service temperature range -25°C ~ +55°C
Transport and storage temperature range -40°C ~ +70°C
Permissible humidity 5% ~ 95%, condensation not permissible

Read more on the web


390 read more on www.nrelect.com www.nrelect.com
Type test
- Electromagnetic compatibility (EMC)
1MHz burst disturbance tests IEC60255-22-1:2007 (idt IEC61000-4-2:1995), Class III
- Common mode 2.5kV
- Differential mode 1.0kV
Electrostatic discharge tests IEC60255-22-2 :2008 (idt IEC 61000-4-2) Class IV
- For contact discharge 8.0kV
- For air discharge 15.0kV
Radio frequency interference tests IEC60255-22-3:2000 (idt IEC 61000-4-3:1995 ) class III
Frequency sweep
- Radiated amplitude-modulated 10V/m(rms), f=80…1000MHz
Spot frequency
- Radiated amplitude-modulated 10Vm(rms), f=80MHz/160MHz/450MHz/900MHz
- Radiated pulse-modulated 10Vm(rms), f=900MHz
Fast transient disturbance tests IEC60255-22-4:2002 (idt IEC 61000-4-4)
- Power supply, I/O & Earth terminals Class IV, 4kV, 2.5kHz, 5/50ns
- Communication terminals Class IV, 2kV, 5.0kHz, 5/50ns
Surge immunity tests IEC60255-22-5:2002 (idt IEC 61000-4-5:1995) , Class III
- Power supply, AC inputs, I/O terminals 1.2/50us, 2kV, line to earth; 1kV, line to line
Conducted RF electromagnetic disturbance IEC60255-22-6:2001, Class III
- Power supply, AC, I/O, Comm. terminal 10V(rms), 150kHz~80MHz
IEC61000-4-8:2001, Class V
Power frequency magnetic field immunity 100A/m continuous
1000A/m for 1-3s
IEC61000-4-9:2001, Class V
Pulse magnetic field immunity 6.4/16 us
1000A/m for 3s
IEC61000-4-10:2001, Class V
Damped oscillatory magnetic field immunity
100kHz & 1MHz – 100A/m

Read more on the web


www.nrelect.com read more on www.nrelect.com 391
Relay Connection Terminals

Introduction
NR provides various reliable state-of-the-art wiring terminals to • The whole series covers various conductor terminating modes:
satisfy different user requirements, including screw terminals, screw connection, weld connection, clamp connection and crimp
weld terminals, clamp terminals and crimp terminals. The connection to satisfy various requirements.
terminals provided by NR feature reliable performance, easy
operation and maintenance, good mechanical properties, high
electric properties, and strong resistance to environmental
conditions.
DL Series Screw Terminals for AC
Inputs
These terminals can be used on all protection and automation
equipment of NR. A series of high quality wiring terminals have DL series terminals are applicable to AC current/voltage inputs,
been developed using screw, crimp, and welded connection and can be used for RCS-900 series protection, RCS-9700
technologies, in combination with specified applications. series bay control unit, PCS-900 series protection among
others.
These terminals provide many various advantages, some of
them being:

• Enhanced flame retarding material is used as insulation, and


has a heat distortion temperature of 250°C, hence making it
suitable for any strong corrosive environment.
• Clips adopt highly elastic copper. Copper surfaces are plated
with gold making them resistant to corrosion.
• The Conducting strip adopts advanced contact technologies DL screw terminal with protective casing DL screw terminal with wire
——wire spring jack or crown spring jack, thereby greatly
increasing its electric contact reliability. These jacks have
very strong current load capacity and can withstand relatively
high current impulses.
• Since the Conducting strips adopt the copper conductor of
gold plated surfaces, they have excellent weldability, are not
harmful to the environment, and satisfy the RoHS instruction
requirements of EU.
• Plugging and unplugging of the connector is easy and free of DL screw terminal without protective casing
stagnation.
0.14 mm² - 4.0 mm² or AWG 26-12 wires can be connected with
a rated operating voltage of 600V, rated operating current of
20A, applicable operating temperature range is -40°C-125°C,
and contact resistance between conductors is less than
1mΩ. Effect on AC quantity measuring precision is small and
application in electric power system can be satisfied.

DL series terminals are complete with CT secondary side


automatic short circuit function and can effectively avoid risk
due to open circuit of CT secondary circuit.

Features
• Traditional screw type press-fit plug structural form

• Wire spring jack structure allowing gentle plugging/


Various Connection Terminals unplugging, small contact resistance, resistance to shock
and vibration, and reliable performance

392 read more on www.nrelect.com


• After unplugging the connector, the external CT circuit
secondary side will be automatically short connected
XH Series Weld Terminals
for DC inputs
• It automatically identifies and matched between the plugs
and sockets and therefore helps to prevent random plugging XH series wield terminals support plug-and-play assembling
• Press-fit connection can be used for cold pressed connector mode so that the user can replace the modules without
or hard wire removing any of the connected wires, thereby increasing
its operational performance and greatly reducing any site
• Easy operational use as the screwed connection has very maintenance time.
low requirements on auxiliary tools.

• Protective casing is optional, to improve its safe protection XH series terminals adopt a reliable welding technique which
performance features reliable connection, small connection resistance, and
life-long maintenance-free property. In addition the provision
of protective casing provides better and more reliable safety
performance as compared with other connectors.
JX Series Screw Terminals
for AC Inputs XH series terminals can be used for binary input/output, power
supply, and DC quantities input/output etc. These terminals
JX series terminals are used for AC current/voltage inputs, and are applicable to RCS-900 series protection, RCS-9600 series
applicable to RCS-9600 series protection, PCS-9600 series protection and RCS-9700 series bay control unit etc. 0.14-2.5
protection, and PCS-9720 series distribution automation unit mm² or AWG 26-14 cables can be connected, rated operating
etc. voltage is 600V, rated operating current is 5A, applicable
operating temperature range is -40°C-125°C, and contact
0.14 mm²-4.0 mm² or AWG 26-12 cables can be connected resistance between conductors is less than 2mΩ. Application in
with a rated operating voltage of 600V and rated operating electric power system can be satisfied.
current of 20A with the applicable operating temperature range
being between -40°C-125°C, and contact resistance between
conductors is less than 1mΩ. Effect on AC quantity measuring
precision is small and its application in electric power system
Features
can be realized. • Plugging/unplugging type terminals allow for card
replacements without removing/re-connecting wires

• The Structural form with the protective casing, providing a


Features high level of safety

• Traditional screw type press-fit wiring structural form

• Press-fit connection can be used for cold pressed connector


or hard wire

• Easy operational use as the screwed connection has very


low requirements on auxiliary tools.

• Protective casing is optional to improve its safe protection


XH weld terminals Internal view of XH weld terminals
performance

• Low contact resistance ensures measurement precision for


AC current/voltage input.

Internal view of XH weld terminal with wire XH weld terminal with wire

• Wire spring jack structure allows for gentle plugging/


unplugging, small contact resistance, resistance to shock and
vibration, and therefore ensures their reliable performance

JX screw terminals JX screw terminal with wire • Wires are connected by soldering, which provide stable,
reliable, small resistance, and life-long maintenance-free
connections

• Repeated wiring at single welded end can be realized by


de-soldering and re-soldering to facilitate modification and
correction of soldering

read more on www.nrelect.com 393


XH Series Screw Terminals for DC XH Series Crimp Terminals for DC
inputs inputs
XH series screw terminals provide two types of structures: XH series crimp terminals adopt advanced crimp connection
traditional screw press-fit wiring and balance wheel clamping technology and have good mechanical strength and electrical
wiring. continuity.

XH series screw terminals are used for binary input/output, These terminals can adapt to severe environment conditions
power supply, and DC quantities input/output etc. These and can be used for binary inputs/outputs, power supply, and
terminals are applicable for RCS-900 8U/12U rack protection DC quantities input/output etc. These terminals are applicable to
and RCS-9600 series protection among others. RCS-900 4U rack protection and RCS-9700 series bay control
unit.
0.14-2.5 mm² or AWG 26-14 cables can be connected with a
rated operating voltage of 600V, rated operating current of 5A, 0.14-2.5 mm² or AWG 26-14 cables can be connected, with
with an applicable operating temperature range of -40°C-125°C, a rated operating voltage of 600V, rated operating current
and contact resistance between conductors is less than 3mΩ. is 5A and thee applicable operating temperature range is
Application in electric power system can be satisfied. -40°C-125°C, and contact resistance between conductors is
less than 4mΩ. Application in electric power system can be
XH series screw type terminals adopting balance wheel satisfied. To install these terminals a special connector crimping
clamping wiring mode and have the advantages of large hole tool shall be used.
position density, strong wiring capacity, front operation, and
good safe protection performance etc.

Features
• Front withdrawal plug form is adopted, providing for simple
structure and easy assembling.

• Crown spring jack structure which is simple and reliable.

• Ferrule removal is simple and fast. Crimp connection wiring


saves at least 50% work time as compared with screw type
XH screw terminals with screw XH screw terminals with balance wiring.
press-fit wiring wheel clamping wiring
• Conductor crimp connection is reliable, has good air
tightness, is resistant to shock and vibration, not subject to
falling, and maintenance free.

• Wide range of applicable wire sizes: from 0.14 mm² to 2.5


mm²; two multi-strand flexible conductors of 1.0 mm² or 1.5
mm² can be smoothly crimp connected.

XH screw terminal with wire • High density hole position wiring can be realized, providing
an outstanding additional advantage.

• Overall protection performance is not lower than IP30, which


is far higher than the specification set by IEC60255-27.
Features
• 2 structural forms: traditional screw press-fit wiring and
balance wheel clamping wiring

• Wire spring jack structure allows for gentle plugging/


unplugging, small contact resistance, resistance to shock
and vibration, and reliable performance

• Press-fit connection can be used for cold pressed connector


or hard wire XH Series Crimp Terminal Ferrule making with tool

• Balance wheel clamping wiring is a derivative form of screw


type wiring and more convenient and faster than the older
screw press-fit wiring system.

• Balance wheel clamping features large hole position density,


strong wiring capacity, front operation, and good safe
protection performance.

• Easy operational use as the screwed connection has very


low requirements on auxiliary tools. Guiding to terminal

394 read more on www.nrelect.com


Installation Instructions
for XH Series Crimp Connection Terminals

Models of Connection Ferrule


and Wire Sizes
User shall select corresponding model of crimp connection • Crimp Connection of Wire
ferrule according to size of connected wire. Load wire core treated above into the connection ferrule shown
in Fig.4. Make sure to place it in the axial position and that
CK2.5 /
CK1.0 CK1.5 CK2x1.5 the surplus single strand wire must not be visible outside the
CK2x1.0
connection ferrule.
Diameter of connection ferrule(mm) ¢ 1.4 ¢ 1.7 ¢ 2.2 ¢ 2.8
ISO nominal cross Insert the ferrule home in the mouth of adjusted connector
1.0 1.5 2.5/2x1.0 2x1.5
Wire size sectional area, mm²
crimping tool in the direction shown in Fig.4, and crimp the
AWG/MCM — 16 14/— —
ferrule as shown in Fig.5. After the connection is made, the
mouth will be released automatically.

Special Tools Note: Adjusting knob of connector crimping tool can be used to
control final position of mouth, to ensure tightness of wire crimp
For installation and wire connection of XH series crimp connection.
connection terminals, special tools are needed including
assembler ZPQ-01, remover QXQ-03, and connector crimping • Assembling of Plug
tool YJQ-001. The connection ferrule after crimp connection is shown in
Fig.6. Normally to push it into the terminal at the wiring side an
assembler tool is not required.

In case the wire cross sectional area is less than 0.75 mm², as
shown in Fig.7, place assembler tool close to the connection
Fig. 1 Assembler ZPQ-01 Fig. 2 Remover QXQ-03 Fig. 3 Crimping tool YJQ-001 ferrule (Fig.6) and insert them together into the terminal. Later,
withdraw the assembler.

Example of Application
• Stripping of Wire Tip
Use stripper to remove insulation layer at tip of multi-strand
wire. Length of exposed conductor shall be ensured at about
Fig. 6 Connection cylinder after crimp Fig. 7 Guiding to feed
8mm. In case two wires need to be pressed into one hole,
the length of the exposed wire core shall be ensured at about
15mm. Exposed parts shall be combined and then about 8mm • Removal
of length shall be reserved for crimping. Remaining exposed In case a wire needs to be removed, as shown in Fig. 8, insert
length of wire core shall wrapped by hot shrink tube. Note that the remover into the hole about 5mm deep in the direction of
stripping of tip must not damage the wire core. mating face and pull the handels back to the end. Then slowly
push it forward till the wire comes out.

Fig. 4 Inserting into mouth Fig. 5 Crimp connection of wire


Fig. 8 Removal

read more on www.nrelect.com 395


APPLICATION SOFTWARE KIT

PCS - Explorer

PCS-Explorer is a software tool designed for the debugging - IEC61850 Configuration


and commissioning of PCS series devices based on UAPC Click the IEC61850 node, parameters related to IEC61850
platform. The software integrates offline visible programming communication will be displayed in the edit window. The edit
configuration, device drive file generation, construction files window has three sub-windows, which are IED, access point
comparison and merging, and online debugging and download and LDevice. Users can modify the properties of IEC61850
functions. communications such as names of access point and Device in
different sub-windows.

Functions Visualized Program Configuration

Project Management Under the “Program Config” node, users can use the visualized
configuration to set device input, output, parameters, and
The PCS-Explorer can be used to manage the configurations configure variables. Double click the “Program Config” node; the
of PCS series device and applications of different operations of existing configurable plug-in modules and the subpages will be
project file in PCS-Explorer. displayed. Users also can create their own pages, then add new
elements, and use relevant editing tools to control the signals
- Operations of Project Files of elements. Moreover, logic programming can be realized to
The PCS-Explorer takes substation as a unit to manage configure customized logic functions under relevant pages (CPU
engineering projects. All PCS series devices in this substation module page or DSP module page).
are grouped in a project for configuration and management.
- Plug-in Modules
- Variable Database and Symbol Database Under the “Program Config” node, configurable plug-in modules
In a newly established or opened existing project file, for the first will be displayed. These plug-in modules are consistent with
click on any device nodes, PCS-Explorer will read the project actual hardware configuration. Generally speaking, module
symbol database automatically and analyze visible documents name is the combination of corresponding slot name and
to form the variable database module type, or the combination of corresponding slot name
and module function.
Offline Configuration
- Page Operations
The PCS-Explorer provides offline configuration function to Specific control rules of relevant signals and parameters of a
manage and control PCS series devices under offline mode, plug-in module are realized by its pages. Number of pages may
including basic information, hardware module, system functions be provided for one plug-in module. Users can operate in pages
and function groups. according to their requirements.

Device configuration covers the configurations of basic


information, hardware module, LCD graphic and IEC61850
communication.

- Device Setup
Click “Device Config”→“Device Setup” node, and four labels
are displayed in the edit window. These labels are used to set
device information, configure hardware module, system level
options and function groups respectively.

- LCD Configuration (LCD Config)


Double click “Device Config→LCD Config” node to display the - Logic Programming Library
“LCD Graph” node. Select “LCD Graph” node to display the Users can set up and combine the required logic functions
contents of the device. through logic programming library. It is supported by CPU board

396 read more on www.nrelect.com


and DSP board and thus logic programming is only available for are downloaded to the device, original configurations, setting,
specific model of CPU and DSP boards. operation reports and recording reports will be deleted by
restarting the device. Please be careful of downloading new
Offline Settings Configuration drive files to device.
Offline settings configuration covers the selection of active
setting group, configuration of settings, printing settings, PCS-Explorer also provides file upload function to upload drive
importing/exporting settings, and uploading/downloading package files from on-line device according to requirements.
settings etc.
Debugging Mode
- Active Setting Group Selection In addition to offline device configuration, PCS-Explorer can
Click “Settings” node to enter ”Settings” interface and unfold be connected to system browse to view device configuration. It
sub-nodes. There are two sub-node types: global setting (Global) also provides users with visible debugging function and online
and group settings (group 1-30). The global setting consists device information viewing.
of various parameters used for device operation. In the setting

groups Group1~Group30, only one group is the active setting


group used in device operation. The active setting group can be - WEB Browse
switched among the 30 groups if required. - Visible Debugging
- Operations of Setting File - Online Check Device Operation Status and Modify
To facilitate browsing and other operations of settings, the PCS- Settings
Explorer also provides users with various operations of setting
files, e.g. print/print preview settings, and import/export setting Programmable Logic Devices
file etc. Programmable logic devices are divided into three symbol
libraries: Boolean, arithmetic operation and data converter.
- Download and Upload Settings
At settings node, users can directly download settings to the - Symbol Library of Boolean Logic Operations
device or call settings file from specified device, and compare The symbol library of Boolean logic operations provides
them with current project settings. common logic arithmetic operation modules of Boolean-variable.

Driver Files - Symbol Library of Arithmetic Operation


The symbol library of arithmetic operation provides a set of
After the project configuration is completed, the configuration
function modules used for arithmetic operations of anolog data,
packages shall be downloaded to the device before application.
If drive packages are used to establish the device node, it shall
- Symbol Library of Data Conversion
be downloaded to the device to activate configurations. In
The data conversion is between single-position and double-
practical, when using online mode to create configurations, drive
position, bit and byte, byte and word, byte and double-word.
packages shall be uploaded from the device to PCS-Explorer
for template creation.
IO plug-in module
IO plug-in symbol library includes BI and BO symbols of
platform NR4000 and platform NR1000 used for PCS devices.

Symbol Library of Configuration Function


The symbol library collection “common” also has a symbol
library named for “Configuration”, which contains two
components, AddEventRecord and PageInfo. 'AddEventRecord'
is used to add signal into incident reports, while 'PageInfo'
is used to record information related to the design in visual
configuration.

- Generate Drive Packages GOOSE_SMV Relevant Modules


- Download and upload files GOOSE_SMV module contains setting symbol blocks related to
Drive packages shall be downloaded to device to activate GOOSE communication to implement corresponding functions,
project configurations. Users shall notice that when packages such as sending and receiving relevant data, warning signals,
trip signals and so on.

read more on www.nrelect.com 397


PCS-PC
Software Kit

The PCS-PC software kit is an auxiliary software designed to simplify the management of
NR’s PCS family products. It provides efficient functionality for device configuration and
commissioning including device setup, configuration & setting, programmable logic development,
test & commission, and fault analysis for PCS series devices. With an intuitive matrix structure,
the software offers easy-to-use configuration capabilities for I/O mapping and signal mapping.
Additionally, sampled values and signal statuses are monitored by the PCS-PC tool. It scans
and retrieves disturbance information for automatic report file generation. Waveform analysis is
integrated for post-fault diagnostic.

PCS-PC takes a substation as a management unit to configure, and is able to manage several
devices in the same substation. It is adaptive to both off-line mode and on-line mode. Under
offline mode, the software can fulfill functions configuration, I/O configuration, programmable
logic and modify settings. Under on-line mode, the software communicates with devices through
Etherne port, downloads program and config documents to devices, modify settings and views
realtime state of devices. Personal computer can connect to the PCS series device via the RJ45
interface in the front plate of the device. The main functions is listed in the table below.

Functions
Functions Offline Online
Modify Setting ● ●
View real-time state of device′s analog
values/binary signals ●
Display event recorder ●
Waveform analysis ●
Remote control ●
Upload/download files ●
Privilege management ● ●
System configuration ● ●
Functions configuration ●
LCD configuration ●
Programmable logic ●
Binary signals configuration ●
Reset LED ●
Time synchronization ●
Read device′s clock ●
Event report read ●
● ●
File download/upload ●
Authority management ● ●

398 read more on www.nrelect.com


- Substation and Device Setup
Substation nodes can be created in PCS-PC auxiliary
software and protection devices can be setup for further
control and management. Users can manage all the
devices via tree structure.

- System Config
System config is used to setup the basic information of
deviced, including recording time, hardware configuration,
display mode and plug-in module configuration. Device
setting can be implemented online or offline.

- Function Config
Functions config can setup each protection function of
device(enable or disable), allowing users to select the
protection functions to be equipped to devices.

- Signal Config
Binary signal config enables users to setup the source and
the type of binary inputs, binary outputs, LED, GOOSE,
analog quantity and LED indicators.

- Setting Config
The software provides setting config function to modify
settings under off-line mode including value display, range,
unit and so on. Under off-line mode, users can modify and
print settings, export and import the setting file.

- Simple Boolean Calculation


The PCS-PC provides simple Boolean calculation by
editing the logic formula. The variable derived from the
calculation result can be used for the configurations of
binary input, binary output and LED indicator.

- LCD Editor
The software allows users to edit LCD main interface,
including display interface, analog quantity, switch, circuit
breaker and the related device type.

- Programmable Logic
The PCS-PC provides programmable logic function to
edit enable/disable protection functions and configure the
output contact of output relay, alarm signal and triggering
signal of recording.

read more on www.nrelect.com 399


RCS-PC
Software Kit

The RCS-PC application software kit is developed for users to set, test and manage NR’s
RCS series products. It can communicate with RCS series protection devices and make the
commission test and management of NR’s relay. It offers full library of RCS series relays and
users can select the appropriate types according to the specific applications. The application
software simplifies commissioning with uploading and downloading of setting files, relay
configuration, event and fault recorder analysis, management of disturbance records, real-
time measurement visualization. It is used to read and modify settings, configure relays, view
sampled values, tripping report, change of binary input and device abnormality. Personal
computer can communicate with RCS series relays via RS-232 port or RJ-45 port and retrieve
messages from relays. The software is based on Windows NT 4.0, Windows 2000 or Windows
XP operating system.

If the communication is built, the type of relay will be displayed, and the title bar will also display
the type of relay and version of firmware.

400 read more on www.nrelect.com


Functions
- Device Setup - Device Status
User can easily select the specified device from the full library Users can view all real time sampling values of AC current,
of RCS series protection device. voltage and phase angle, the calculated values of differential
currents, sequential current/voltage, harmonics, all binary inputs
status and save them as a file.

- Report
Users can view various reports, including tripping report,
abnormality report and changes of binary input. They can be
saved as recorder files respectively. The waveform records
will be stored with the format of COMTRADE. They can be
displayed and analyzed by the integrated analysis tools. All
these reports can be printed via RCS-PC.

- Waveform Analysis
Users can read, view and analyze the recorded waveform from
the protection devices. The user can also save the wave files
- Firmware Downloading and open it later.
Users can download the newest firmware and check the current
version of firmware from manufacturer to update the device.

- Device Configuration
Users can configure the binary inputs/outputs, programmable
logics, LEDs via RCS-PC if the devices support.

- Signal reset
Users can reset all magnetic latched output relays and signal
relays via RCS-PC by clicking the “Signal reset” button.

- Clock Synchronization
Users can synchronize the clock of the device as the time of

- Settings personal computer.


Users can view and modify active settings of a relay, upload
current setting file from the relay, download setting file to the
relay, save current settings as a file, read settings from a setting
file, print current setting, check and highlight out-of-range
settings and restore to default settings.

read more on www.nrelect.com 401


SCL Configuration Tool

Event and Check Output Window, and configuration area. Uses


can create, open, edit and save an SCL file through this main
interface.

The SCL configuration tool is appicable to the engineering


implementation of IEC61850. It is the visual configuration tool Configure an SCL File
used to configure SCL files, including creating and editing SCL • Header Configuration
files, and viewing SCL files that are conform to IEC61850-6.
Users can construct the substation configuration, structures, Through the header configuration window, users can
models throught this professional tool, and quickly design and configuration of changed information lists in the SCL file,
manage the substation setting. The SCL configuration tool and provides operations such as New, Delete, Move Up and
provides the following functions: Move Down for changed information.

• Create the substation configuration description(SCD) file in


accordance with IEC61850-6 regulations.

• Build the single line diagram for the primary system of the
substation.

• Manage the version of SCD files.

• Construct different substation structures and create the


complete system specification description (SSD).

• Import the IED into the ICD which conforms to IEC61850-6.

• Associate different intelligent electronic devices and the


logical nodes(LN) to substation details, and complete • Communication Configuration
the configuration of the substation system according to
The communication configuration window provides the
IEC61850-6.
configuration of SubNetwork lists in the SCL file, and
• Edit and maintain the functions and date elements in IED. provides operations such as New, Delete, Move Up and
Move Down for every SubNetwork.
• Define the substation communication configuration.

• Check the data templates and solve the conflicts.

• Standard SCL Schema Verification.

• Expanded grammar and semantic check.

Funcitons
Create, save and edit SCL Files
The main interface includes the Menu Bar and Tool Bar, SCL
Browser Window, IED Selection Window and Property Window,

402 read more on www.nrelect.com


• Subnetwork Configuration • Substation Configuration

Through the SubNetwork configuration window, users can The Substation Configuration Window enables the specific
configure ConnectedAP, Address, GSE and SMV under one configuration of one certain Substation in the SCL file.
SubNetwork in the SCL file.
The SCL configuration tool supports the construction of
For each created ConnectedAP, SCL Configurator will single line diagram for the primary system of substation in
create a default Address configuration item, and meanwhile the graphical form, automatically generates the substation
the GSEControl and SampledValueControl under the model which conforms to the definition in IEC61850-6
AccessPoint will generate the corresponding GSE and SMV according to the single line diagram and sets the association
configuration items for each control block. of substation model with the logical node of IED, etc.

• IED List Configuration

The IED List Configuration Window provides the


management and configuration of all IEDs in SCL files, such
as creation, updating and deletion of IED; adjust the position
of one certain LED in the SCL file; and edit the attributes of
IED.

• IED Configuration

The IED configuration window provides the specific


configuration of one certain LED in the SCL file. There are
two combo boxes on the top of the configuration interface,
which provide the screening of the LDevice and LN under
the current IED respectively. While selecting one specific
LDevice and LN in the combo box, all configurations will be
conducted to the LDevice or LN.

read more on www.nrelect.com 403


Appendix Device Diemension Diagram

PCS Series Standard 4U Device

PCS Series Standard 8U Device

PCS-9600 Series Standard 1/2 4U Device

RCS-900 Series Standard 4U Device

404 read more on www.nrelect.com


RCS-900 Series Standard 8U Device

RCS-900 Series Standard 12U Device

RCS-900 Series Standard 12U Device

Read more on the web


www.nrelect.com read more on www.nrelect.com 405
RCS-9000 Series Standard 1/2 6U Device

RCS-9000 Series Standard 1/3 6U Device

RCS-9000 Series Standard 1U Device

Read more on the web


406 read more on www.nrelect.com www.nrelect.com
2012 Product Catalog
NR ELECTRIC CO., LTD.

69 Suyuan Avenue, Jiangning, Nanjing 211102, China


Tel: +86 25 8717 8888
Fax: +86 25 8717 8999
E-mail: [email protected]
[email protected]
Website: www.nrelect.com (EN)
www.nari-relays.com

You might also like