Shunt Current Sensor IVT-MOD
Shunt Current Sensor IVT-MOD
Isolation –
Automotive / Industrial automotive
Current measurement range ±100 A; ±300 A; ±500 A, ±1 kA; ±2.5 kA
Voltage measurement range ±600 V (0 - 3 channels)
Hardware Trigger (input)
I/O
Hardware Overcurrent signal (output)
Connector JST (JWPF)
IVT-MODular
3. Additional features
The IVT-MOD has a high number of features. The following fea- 3.2 Internal safety
tures are available for all modular combinations.
The sensor status is internally monitored by the microcontroller. In
3.1 Measurement modes case of a sensor failure a status bit is set. To verify the current mea-
surement of the first channel, a second virtually independent ADC
Disable channel is used. The system compares the signal of both channels
Trigger to determinate malfunctions in the ADC. Furthermore the ADC’s
Cycle running reference voltage is monitored. Therefore the IVT-MOD can detect a
It is possible to configure each channel individually. non-valid measurement condition on the current channel.
Disable mode
The measurement channel is disabled. The channel does not react 3.3 Log data
to a software command or hardware trigger. The log data are continually stored, with an interval of 15 minutes
if the IVT-Mod is configured in run-mode. In case of a sensor reset,
Trigger mode the last stored logdata will be recovered. It is possible to reset all
The module sends a measurement result message in response to a logdata, as well as individual logdata.
received trigger command. This command can be either a software
message or a hardware trigger line signal. In case of a detected
hardware trigger signal, the module starts one single measurement
cycle.
IVT-MODular
4. Functionality description
Module overview
ADC
Over current
+
detection
Shunt
Ground
Microcontroller
Hardware trigger
CAN
Connector
Minimum
Modularity
configuration
4.1 Isolation
This functionality is designed for high voltage applications. potential levels on power supply (low voltage side) and shunt (high
With the isolation module the sensor can be used with different voltage side).
IVT-MODular
5. Measurement description
Depending on the selected functionality there are up to eight measurement output signals (Table 1: list of output signals). Every signal can
be configured individually (output transfer rate and value). Based on these variations a high number of applications are possible, i.e. a fast
current measuring as well as a complete filtered measuring of all signals.
IVT-MODular
6. Technical Data
1
without isolation
2
with isolation
3
depends on the modularity
4
failure of reading
5
with temperature calibration
6
in nominal measurement range
7
without averaging
Issue IVT-MOD-2015-07-14 // Version 1.0 5 / 9
Isabellenhütte Heusler GmbH & Co. KG // [email protected] // The current valid issue of the data sheet can be found on www.isabellenhuette.de
ISAscale® // High precision measurement
IVT-MODular
6.4 Communication
Interface Specification Speed Termination Max. number of Unit
CAN 2.0 a 250kbit/s; 500kbits/s; 1Mbit/s 120R 6
6.5. Connector
Manufacturer Type No. of pins Colour Man. part no.
2 red B02B-JWPF-RK-R (LF)(SN)
Modul connector JST JWPF
4 black B04B-JWPF-KK-R (LF)(SN)
2 red 02R-JWPF-VRLE-S
Wire connector JST JWPF
4 black 04T-JWPF-VKLE-S
Crimp contact JST – – SWPR-001T-P025
CAN termination
ISA JWPF 4 black –
connector
IVT-MODular
1,000 / 2,500 A
40,4 40,4
24,8
14,2
24,8
4
14,2
2,5
2,5
84
4
10 64
13,6
x)
8 ,3 (4
84
64 35,8
18
85,3
13,6
8,3
62,8
35,8
8,9
18
(4 x
)
40,4 40,4
24,6
14,2
24,8
14,2
3,5
3
3,5
3
84
10 64
84
19,8 13,6
64
8,3 (
2x)
20 13,6
85,3
8,3 (2x)
62,8
Z-DC-473
IVT-MODular
Note: There is no short circuit protection of the GND Line. In case of wrong wiring the sensor can possibly be destroyed!
IVT-MODular
Voltage Channel
U0 / U1 / U2 / U3
Add. Feature
T ó Trigger
O ó Overcurrent detection
I ó galvanic Isolation
Communication
CAN1 ó CAN-Termination on Board
CAN2 ó No CAN-Termination on Board
Power Supply
12 ó typ. 12 V
24 ó typ. 24 V
7. Qualification
Name Standard
ESD immunity ISO 10605:2008
Immunity to radiated
ISO 11452-2:2004
electromagnetic fields
Conducted transient immunity and
ISO 7637-2:2004
conducted transient emission
Conducted emission and radiated emission CISPR25:2008
ISO 16750-2 immunity ISO 16750-2:2010
MBN-LV124:2009 (L-02 life test)
climatic load ISO 60664-3:2010 (insulation resistance test)
ISO 20653 (IP protection class)
Disclaimer // All products, product specifications and data are subject to change without notice. The product specifications do not expand or otherwise
modify Isabellenhütte’s terms and conditions of sale, including but not limited to, the warranty expressed therein. Isabellenhütte makes no warranty, represen-
tation or guarantee other than as set forth in its terms and conditions of sale. Information provided in datasheets and/or specifications may vary from actual
results in different applications. Any statements made by Isabellenhütte regarding the suitability of products for certain types of applications are based on its
knowledge of typical requirements that are often placed on its products. It is the customer’s responsibility to validate that a particular product with the proper-
ties described in the product specification is suitable for use in the application intended. No license, express or implied, or otherwise, to any intellectual prop-
erty rights is granted by this document. Any and all liability arising out of the application or use of any product shall be as set forth in Isabellenhütte’s terms
and conditions of sale. 9 / 9
Isabellenhütte Heusler GmbH & Co. KG // [email protected] // The current valid issue of the data sheet can be found on www.isabellenhuette.de
Issue IVT-MOD-2015-07-14 // Version 1.0