Mill Circuit Solutions: GIW Hard Rock Mining Pumps
Mill Circuit Solutions: GIW Hard Rock Mining Pumps
Mill Circuit Solutions: GIW Hard Rock Mining Pumps
GIW MDX
Design Features:
Optimal Wear Life with “Slurry Diverter”
Patented Inlet 5V Impeller: Designed to handle both Adjustable Suction Liner: Extended suction liner wear life
liquid and solid phases within the slurry. This maximizes maximizes productivity and minimizes cost by matching
pump performance and wear life. operating cycle times with scheduled mill outages.
3
Flowrate (m3/hr)
180 54
160 48
140 42
400
600
MDX 500
200
MDX 00
MDX 0
MDX 0
650
MDX 50
350
750
150
25
45
3
5
120
Head (m)
Head (ft)
36
MDX
MDX
MDX
MDX
MDX
MDX
MDX
100 30
80 24
60 18
40 12
20 6
0 0
1,000 10,000 100,000
Flowrate (gpm)
70
4 LSA
300 80
21SA
22x2
300
3x4 L
53 60
Head (m)
Head (ft)
Head (m)
Head (ft)
C 26
28
200
24
0
6
2
26x LSA 48
8
C
A 44
2
16x1 LSA 36
A 39
LCC 1
LCC 9
LCC 1
LCC 2
SA 5
0 LCC
12 L 5
12 LC
16 LC
SA 3
200
25
25
21
35
LSA
8 LS
6 LS
40
LSA
LSA
LSA
28 L
3x4
2x3
4x6
6x8
8x1
24
21
10 x
14 x
4
8x10
18x1
12x1
20x
6x8
4x6
4x6
10x
LSA
100
100
2x3
18 20
0 0 0 0
100 1,000 10,000 100 1,000 10,000 100,000
Flowrate (gpm) Flowrate (gpm)
4 GIW Hard Rock Pumps
MDX / LSA
LCC
LCC
ZW
LSA HP / TBC
HYDROCYCLONES
HVF
Most Severe
MDX
Q m³/h 14,000
The latest technology from GIW provides superior wear life and increased uptime handling Hm up to 90
your most aggressive slurry applications. Ideal for grinding circuits, SAG and Ball Mill p bar up to 16
discharge and cyclone feed. T °C up to +120
LSA-S
Q m³/h 14,000
Premium design, hard iron pumps for long wear life while handling severe slurries. The Hm up to 90
basic, single wall construction and heavy suction, hard metal wet end combined with the p bar up to 16
cartridge bearing assembly provides maximum reliability and easy maintenance. T °C up to +120
TBC
Q m³/h 18,200
A high-pressure design, these pumps are constructed as horizontal, end suction centrifugal Hm up to 90
pumps to give maximum resistance to wear while simplifying maintenance. The conventional p bar up to 55
single-wall design transfers stress loads to non-wearing side plates in high pressure applications. T °C up to +120
LCV
Q m³/h 1,360
Vertical cantilever, rugged hard metal sump pump with bottom suction and no submerged Hm up to 38
bearings. Includes replaceable wet end parts in metal alloys with a durable mechanical end. p bar up to 10
Ideal for industrial process pumping, tailings disposal in mining and pit use. T °C up to +120
Hydrocyclone
GIW‘s line of hydrocyclones features a patented long wearing design that can reduce T °C up to +120
rebuild time by up to 75%. Diameters available up to 840mm.
Heavy Duty
LCC-M / LCC-R
Q m³/h 3,865
The hydraulic wet end consists of three components: a shell or casing, an impeller and a Hm up to 90
suction plate/liner to permit easy removal for maintenance and inspections. Reliable pumps
p bar up to 16
for high discharge head, mildly corrosive slurries and a wide range of particle sizes.
T °C up to +120
ZW
Q m³/h 400
Vertical cantilever, rugged hard metal sump pumps with top and bottom suction, no sub- Hm up to 35
merged bearings. Replaceable wet end parts in metal alloys with a durable mechanical end. p bar up to 10
T °C up to +120
7
Process
Multitec
Q m³/h 850
Hm up to 630 (800 )
High-pressure pump in ring-section design, with axial or radial suction nozzle and cast
p bar up to 63 (80)
radial impellers. Design to ATEX. Ideal for water supply systems and general industry.
T °C up to +200
KWP
Q m³/h 1300
Horizontal, radially split volute casing pump in back pull out or close coupled design, single Hm up to 100
stage, single entry, available with various impeller types: non clogging impeller, free flow p bar up to 10
impeller. Design to ATEX. Ideal for all types of slurries without stringy substances and pulps
up to 5% bone dry with a maximum density of 1.1 kg/dm 3. T °C up to +280
Amarex KRT
Q m³/h 10800
Vertical, singlestage submersible motor pump in close coupled design, various impeller types, for Hm up to 100
wet or dry installation, stationary and transportable version. Design to ATEX. Can handle all p bar –
types of abrasive or aggressive waste water. T °C up to +60
CPKN
Q m³/h 4150
Horizontal, radially split volute casing pump in back pull out design to EN 22 858 / ISO Hm up to 185
2858 / ISO 5199, single stage, single entry, with radial impeller. Also available as variant p bar up to 25
with “wet” shaft, conical seal chamber, heatable volute casing (CPKNO-CHs) and/or
semi open impeller (CPKNO). Design to ATEX. Suitable for heap leaching applications. T °C up to +400
Etanorm/Etanorm R
Q m³/h 1900
Horizontal, long coupled, single-/two-stage volute casing pump in back pull out design. Hm up to 170
Replaceable shaft sleeves/shaft protecting sleeves and wear rings. Design to ATEX. Ideal for p bar up to 25
water supply systems. T °C up to +105
Omega
Q m³/h 2880
Axially split, single-stage volute casing pump for horizontal or vertical installation with Hm up to 100
double-entry radial impeller, connection flanges drilled to DIN, ISO, BS or ANSI standards. p bar up to 10
Ideal for raw water or reclaim water applications. T °C up to +280
B Pump
Q m³/h 2000
The assembly is formed by turbine assembly, discharge column and drive stand (for solid Hm up to 300
shaft driver) or distributor (for hollow shaft driver). Ideal for raw water applications. p bar up to 20
T °C up to +80
RDL / RDLO
Q m³/h 10000
Single-stage, axially split volute casing pump for horizontal or vertical installation with Hm up to 240
double-entry radial impeller, mating flanges to DIN, ISO, BS or ANSI. p bar up to 25
T °C up to +70
First Class Service Worldwide
Manufacturing Centers REGEN Service Centers
A KSB Company .