Model Model: Cable Operated Safety Stop Control For Conveyors Cable Operated Safety Stop Control For Conveyors
Model Model: Cable Operated Safety Stop Control For Conveyors Cable Operated Safety Stop Control For Conveyors
Model Model: Cable Operated Safety Stop Control For Conveyors Cable Operated Safety Stop Control For Conveyors
RS TECHNICAL INFORMATION 5. The Model RS controls are listed by UL, Inc. and CSA Group.
The general purpose models are listed for non-hazardous
MODEL DESCRIPTION atmospheres. Explosion proof models are listed for use in
hazardous atmospheres as defined by the National Electric
RS-1 One SP/DT microswitch, weatherproof
Code handbook and the National Electrical Manufacturers
RS-1X Explosion proof with one SP/DT Association Standards for NEMA type 7 and 9 hazardous
microswitch, for NEMA 7 and 9 locations. Specifically, they are listed for Class I, Div 1,
Groups C and D; and Class II, Div. 1, Groups E, F and G.
RS-2 Two SP/DT microswitches, weatherproof
6. Model RS offers the lowest cost per foot of protection
RS-2L Two SP/DT microswitches with external signal light,
because it incorporates fewer switches and less wiring is
includes 120V lamp, weatherproof
required. Cable may be extended in either or both directions
RS-2X Explosion proof with two SP/DT with no changes required in the internal mechanism of the
microswitches, for NEMA 7 and 9 unit and the wiring is still of a simple uncomplicated nature.
RS-5 Two DP/DT microswitches, weatherproof 7. The unit is available with a warning light that may be wired
to indicate actuation. This permits easy identification
RS-5X Explosion proof with two DP/DT microswitches, for
NEMA 7 and 9 of actuated units in areas where visual identification
is difficult.
Note: Dual-Rated enclosures also available. Contact Sales for details.
DETENT
SIGNAL LIGHT
(Optional)
ALUMINUM
ALUMINUM 3/4” NPT CASTING BASE
CASTING TOP CONDUIT OPENING
(Cut-Away View) (3 Places)
CABLE
POSITIONS SWITCH
3 ACTUATING
1
2 ARM
TOTAL ACTUATION
POSITION FORCE REQUIRED
(LBS)
1 As shown in the chart and picture of the actuating arm, the
1 40 actuation force can be varied by attaching the cable at any one
2
3 of the three positions.
2 28
The cable should be supported by eyebolts every 8-10 feet
3 20 (3m). These supports ensure that the weight of the cable alone
will not actuate the control.
NPT
CABLE SUPPORT EYE BOLT CABLE END FITTING SAFETY CABLE CONDUIT PLUG
1/2” x 6” plated 2-1/2” long Secures protective cable to 3/32” x 7x7 preformed, 3/4” metal, socket
N.C. thread. 1” eye, two nuts switch hand and supports. galvanized aircraft cable. head conduit plug.
and one lockwasher. Item # RS-28 Protective coating in either Item # RS-29
Item # RS-27 orange coated vinyl or nylon.
3/16” O.D.
Item # RS-25 (vinyl)
RS-26 (nylon)