Securico Sensor
Securico Sensor
Document No.:___________
Please read this manual carefully before operating your security system and retain it
for future reference. If you have any questions related to our products, kindly write to
us at [email protected].
WARRANTY
This product is sold subject our standard warranty conditions and is warranted against
defects in workmanship for a period of one year. In the interest of continuing improvement
of quality, customer care and design, the company reserves the right to amend
specifications and features without giving prior notice. The company also reserves the
right to replace existing devices with new upgraded versions under the warrantee policy.
INTRODUCTION
Congratulations on being the proud owner of Galaxy GSM, a step into ultramodern
protection. Panel was created to meet today's technologically advanced demands of
integrating security with automation. Galaxy GSM, our super control panel is 40 zone panel
with a built-in 2 message 20 number GSM auto dialer, which will automatically call you, your
friends, your family and the police in case of an emergency. Its automatic arming and
disarming facility brings easy security to your door step. The ability to protect your lifestyle
and automate it all at the same time. We wish you a peaceful life and an enjoyable Galaxy
experience!
ABOUT SECURICO
Securico has completed 34 successful years of manufacturing excellence and offers a
complete range of Electronic Security Solutions including Intruder Alarms, CCTV Systems,
Fire Alarms, Video Door Phones, Energy Saving Devices and a State of the Art 24X7 Video
& Alarm Monitoring Station. Securico is the chosen brand of more than 3000 security
system integrators in over 250 cities across India. With a highly qualified in house R&D
team and modern manufacturing plant, Securico is totally committed to providing the
security industry with high tech, multi functional, top quality, low cost yet world class
products. Securico is privileged to have a large number of Indian and multinational banks
along with thousands of corporate, commercial, retail and residential users as satisfied
clients which has been achieved through three decades of impeccable customer service
and care.
GALAXY 4016 GSM
FEATURES
Ÿ Micro-controller based
Ÿ 24 wired zones expandable to 40 zones
Ÿ Can connect up to 16 wireless sensors by adding wireless receiver
module
Ÿ Inbuilt GSM based speech and SMS dialer module
Ÿ Separate remote key pad with 16x4 LCD display and 16 key back
lit key pad
Ÿ Can attach up to 3 additional LCD display remote key pads
Ÿ Android app to operate and program panel
Ÿ 1 admin code and 3 user codes
Ÿ 3 sub partitions with programmable schedule
Ÿ Scheduled partitions and zones
Ÿ Automatic arming and/or disarming, optional and programmable
Ÿ One day holiday programmable for automatic disarming feature
Ÿ GSM dialer module supports 2 speech / voice messages
Ÿ Separate intrusion message
Ÿ Separate fire message
Ÿ 10 telephone numbers for intrusion message
Ÿ 10 telephone numbers for fire message
Ÿ 20 second recording time for each message
Ÿ Multiple Alarm and Status SMS
Ÿ Alarm SMS with alarm type, zone number, time and date
information
Ÿ Alarm SMS types - intrusion alarm, panic alarm, fire alarm,
tamper and wrong code
Ÿ Status SMS sent to admin user on first number - system arm,
admin disarm, user disarm, system on, AC power on, AC power
off, low battery, admin or user code change, telephone number/s
added, telephone number/s deleted, daily heath status.
Ÿ Daily System On health status SMS sent once a day to admin
user on first number
Ÿ Power status SMS for AC power on/off, low battery
Ÿ User editable name and address for alarm SMS
Ÿ Message playback
Ÿ Android App is SMS based, no internet required for daily use
Ÿ All key panel functions and features programmable from app
Ÿ All alarm alerts and status events received, displayed and
logged in the app
Ÿ Panel can also be operated through mobile via simple SMS
commands
Ÿ Automatic temporary bypass of open 24 hour zones in case
of open zone
Ÿ Detectors connected to fire zones are automatically reset
after one hour in case of an alarm
Ÿ Optional panic and fire zone expander modules
Ÿ Inbuilt silent panic zone and option of up to 4 additional silent
panic zones through zone expander module
Ÿ Built in provision for 12V 7AH SMF battery
Ÿ Zone omitting facility
Ÿ Silent arming
Ÿ Night mode arming
Ÿ Intrusion log with time and date
Ÿ 500 Event log for alarms and menu access
Ÿ Open and close information for alarm zones
Ÿ Dedicated panic, fire and quick arm keys
Ÿ Silent dialing
Ÿ Power failure indication
Ÿ Battery strength display with audio indication in case of low
battery
GALAXY 4016 GSM
1 GETTING STARTED 01
1-1 GET TO KNOW YOUR GALAXY 01
1-2 CONFIGURATION 03
1-2-1 PREVIOUS SETTING MODE 03
1-2-2 FACTORY SETTING MODE 04
1-3 FACTORY SETTING 05
1-4 SYSTEM STATUS 07
1-5 OPERATING PROCEDURES 07
1-6 ZONES 07
2 OPERATING PROCEDURE 1 -
THROUGH REMOTE KEY PAD 09
2-1 TO ARM THE SYSTEM 09
2-1-1 FULL ARMING 09
2-1-2 NIGHT ARMING 10
2-1-3 SILENT ARMING 10
2-2 TO DISARM THE SYSTEM 11
2-3 MENU OPTIONS 11
2-4 OMIT ZONES & ARM SYSTEM 12
2-5 INTRUSION LOG 14
2-6 CHANGE CODE 15
2-6-1 CHANGE ADMIN CODE 15
2-6-2 CHANGE USER CODES 17
2-7 SET TIME & DATE 18
2-7-1 SET TIME 18
2-7-2 SET DATE 19
GALAXY 4016 GSM
1 - GETTING STARTED
FRONT VIEW 1
4
3
2
5
6
10
9 7
8
11
BACK VIEW
16
15
14
01
FRONT VIEW
BACK VIEW
14. Speaker
15. Wire Opening Slots
16. Flexible Slots for Screw Mount Installation
02
GALAXY 4016 GSM
1-2 CONFIGURATION
GALAXY
1- PREVIOUS
SETTING
2- FACTORY
SETTING
GALAXY
RESTORING
PREVIOUS
SETTINGS
GALAXY
UPDATING DATA...
03
The screen will display:
GALAXY
GALAXY
RESTORING
FACTORY
SETTINGS
GALAXY
UPDATING DATA...
04
GALAXY 4016 GSM
CODES
ENTER + USER ID + USER CODE
ENTER + UI + XXXX
USER IDs
User IDs are fixed and cannot be changed.
ADMIN : 00
USER 1 : 11
USER 2 : 21
USER 3 : 31
FACTORY SETTINGS:
ADMIN CODE : ENTER + 00 + 1234
USER 1 CODE : ENTER + 11 + 1234 (Zone No. 1 to 8)
USER 2 CODE : ENTER + 21 + 1234 (Zone No. 20)
USER 3 CODE : ENTER + 31 + 1234 (Zone No. 21)
05
ZONE NO DESCRIPTION USER SIREN / SILENT
Zone 14 Immediate ADMIN SIREN
Zone 15 Panic (24*7) ADMIN SIREN
Zone 16 Panic (24*7) ADMIN SIREN
Zone 17 Fire (24*7) ADMIN SIREN
Zone 18 Fire (24*7) ADMIN SIREN
Zone 19 Silent Panic 24*7 SILENT
Zone 20 Delay ADMIN/USER-2 SIREN / SILENT
Zone 21 Delay ADMIN/USER-3 SIREN / SILENT
Zone 22 PIR Zone ADMIN SIREN / SILENT
Zone 23 AC ON/OFF NA SILENT
Zone 24 Tamper (24*7) ADMIN SIREN
Zone 25 Panic (24*7) ADMIN SIREN
Zone 26 Panic (24*7) ADMIN SIREN
Zone 27 Panic (24*7) ADMIN SIREN
Zone 28 Panic (24*7) ADMIN SIREN
Zone 29 Silent Panic (24*7) ADMIN SILENT
Zone 30 Silent Panic (24*7) ADMIN SILENT
Zone 31 Silent Panic (24*7) ADMIN SILENT
Zone 32 Silent Panic (24*7) ADMIN SILENT
Zone 33 Fire (24*7) ADMIN SIREN
Zone 34 Fire (24*7) ADMIN SIREN
Zone 35 Fire (24*7) ADMIN SIREN
Zone 36 Fire (24*7) ADMIN SIREN
Zone 37 Fire (24*7) ADMIN SIREN
Zone 38 Fire (24*7) ADMIN SIREN
Zone 39 Fire (24*7) ADMIN SIREN
Zone 40 Fire (24*7) ADMIN SIREN
TIMER SETTINGS
ENTRY TIME : 30 SECONDS
EXIT TIME : 30 SECONDS
SOUNDER TIME : 2 MINUTES
06
GALAXY 4016 GSM
DISARMED/DAY MODE
The system is in day mode when it is not armed. In this mode, only 24
hours active zones will be actively operational. The time, day and date will
be displayed on the remote key pad LCD screen.
ARMED MODE
The system is in the armed mode when all active* zones are operational
and can be triggered to raise an alarm.
1-6 ZONES
07
IMMEDIATE: An immediate zone will actively raise an alarm only if the
system is armed. If anyone enters the premises through an immediate
zone while the system is armed, the alarm will sound immediately.
Immediate zones usually include all the doors and windows other than the
main entry, since the user is unlikely to enter the premises through
these.
PANIC: A Panic zone is a 24 hour active zone and will raise an alarm when
the panic switch is pressed irrespective of whether the system is armed
or disarmed.
SILENT PANIC: A Silent panic zone is a 24 hour active zone and will send
ALARM SMS and call on preset numbers without raising an alarm when
the panic switch is pressed irrespective of whether the system is armed
or disarmed.
FIRE: A Fire zone is a 24 hour zone and will raise an alarm in case a fire is
detected irrespective of whether the system is armed or disarmed.
TAMPER: A Tamper zone is a 24 hour active zone and will raise an alarm in
case of tamper violation in the panel or sensors (if connected) and if the
tamper wire is cut irrespective of whether the system is armed or
disarmed.
08
GALAXY 4016 GSM
Arming options:
FULL ARM: The system is fully armed when all existing zones have been
armed.
Press ENTER
Press FULL
All zones will be armed and the screen will display:
GALAXY
AC
Delay arming beeps will sound from the remote keypad during the exit
delay.
GALAXY
AC
09
2-1-2 NIGHT ARMING
This unique feature enables you to temporarily make all delay (entry/ exit)
zones into immediate zones. In the case that all users are within the
premises when the system is armed at night and no delay zones are
required, the Night Arming feature can be used. This feature is
particularly helpful when the system is installed in a residence.
Full Night Arming:
Press ENTER
Press FULL
Press NIGHT/9
All zones will be armed and all delay zones will temporarily become
immediate zones and the screen will display:
GALAXY
AC
If the delay arming beeps are not required, They can be silenced. The
system will arm itself silently ending with a long ending beep to indicate
the system is armed.
Full Silent Arming:
Press ENTER
Press FULL
Press 6 / SILENT
10
GALAXY 4016 GSM
All the zones will be armed silently and the screen will display :
GALAXY
AC
Note: The control panel will only accept the admin code once the first
number has been dialed.
11
TIMER SETTING
AUTO OPERATION
PLAY & RECORD MESSAGES
To select a menu option, scroll down using the NEXT button and press
ENTER
To skip and go to the next menu option press NEXT
To skip and go to the previous menu option press 0
To exit the menu and return to Day Mode, press EXIT
This option allows you to omit zones temporarily and arm the system.
GALAXY
OMIT ZONES
& ARM SYSTEM
Press ENTER
GALAXY
SELECT WINDOW
1 - ZN 01 - 15
1 - ZN 16 - 30
1 - ZN 31 - 40
Select the window number as per the zone number you wish to omit.
Example: If you want omit zones from zone number 01 to 15 PRESS 1 to
select window 1
12
GALAXY 4016 GSM
The display will change to:
GALAXY
WINDOW 1 ZN01 - 15
Enter the zone numbers you wish to omit (enter 01 for Zone 1, 02 for
Zone 2 etc).
Note: 24 hour zones (PANIC, FIRE & TAMPER cannot be omitted)
Press ENTER to confirm
The display will change to:
GALAXY
WINDOW ZN01 - 15
02
PRESS EXIT
The display will change to:
GALAXY
ZONES UPDATED
PRESS ENTER TO
ARM THE SYSTEM
PRESS ENTER
13
The display will change to:
GALAXY
PRESS FULL
AC AC
The intrusion log displays the last 500 events of alarms with alarm zone
open and close where applicable and menu access.
GALAXY
INTRUSION LOG
Press ENTER
GALAXY
INTRUSION LOG
1 - LOG DETAILS
14
GALAXY 4016 GSM
Press 1
GALAXY
The admin code disarms the entire system. The menu and all
programmable features can only be accessed with the admin code.
GALAXY
CHANGE CODE
PRESS ENTER
15
GALAXY
CHANGE CODE
1 - ADMIN CODE
GALAXY
RE-ENTER CODE
GALAXY
CHANGE CODE
SUCCESSFULLY
Note: If both new entered codes are not same an error message will
be displayed and the code will not be changed.
16
GALAXY 4016 GSM
This option allows user to change their user codes. There are 3 users in
this panel and each user can change only their code.
Enter previous code
GALAXY
CHANGE CODE
PRESS ENTER
GALAXY
CHANGE CODE
1 - USER CODE
GALAXY
17
The screen will display:
GALAXY
CODE CHANGE
SUCCESSFULLY
Note: If both new entered codes are not same, an error message will be
displayed and the code will not be changed.
The screen will display:
GALAXY
PASSWORD NOT
MATCHED
PLEASE TRY
AGAIN
The RKP screen displays the time and date at all times. The time and date
need to be set at the time of programming the panel. The same time
setting is also used for the Auto Operation feature.
GALAXY
18
GALAXY 4016 GSM
Press 1 to set time
The screen will display the current set time:
GALAXY
Use numeric keys to enter hours and minutes. Press NEXT to move to
the next digit after entering each digit
To go to the previous digit option press 0
Press ENTER to confirm.
GALAXY
GALAXY
19
Use PANIC KEY and FULL KEY to set days.
Press NEXT to shift the cursor to the next position.
Use numeric keys to set date.
Use PANIC KEY and FULL KEY to select the month
Use numeric keys to set year.
Press NEXT to shift the cursor to the next position.
Press ENTER to confirm.
GALAXY
TIMER SETTING
Press ENTER
The screen will display:
GALAXY
TIMER SETTING
1-ENTRY TIME
2-EXIT TIME
3-SOUNDER TIME
ENTRY TIME: The entry time is the time the user has to enter the code
before the alarm sounds when entering from an entry / exit (delay) zone.
This time is programmed by the user and can vary from 2 to 255 seconds.
EXIT TIME: The exit time is the time after arming the system in which any
open entry / exit zones must be closed. This time is programmed by the
user and can vary from 2 to 255 seconds.
20
GALAXY 4016 GSM
SOUNDER TIME: The sounder time is the duration for which the alarm will
sound in case of an alarm. This time is programmed by the user and can
vary from 2 to 20 minutes.
GALAXY
TIMER SETTING
1-ENTRY TIME
2-EXIT TIME
3-SOUNDER TIME
ENTRY TIME
ENTER 2-255
SECONDS
030
GALAXY
TIMER SETTING
1-ENTRY TIME
2-EXIT TIME
3-SOUNDER TIME
21
The screen will display:
GALAXY
EXIT TIME
ENTER 2-255
SECONDS
030
GALAXY
TIMER SETTING
1-ENTRY TIME
2-EXIT TIME
3-SOUNDER TIME
SOUNDER TIME
ENTER 2-20
MINUTES
02
Auto Operation allows the panel to arm and disarm at a preset time Daily
(automatic arming and disarming). There is also a provision for one holiday
in a week when the panel will remain armed. Both automatic arming and
22
GALAXY 4016 GSM
disarming are independent features and can be used separately. This
option can be manually overridden at any time by following standard
arming and disarming procedure.
GALAXY
AUTO OPERATION
Press ENTER
The screen will display: GALAXY
AUTO OPERATION
1-ARMING TIME
2-DISARMING TIME
3-SET HOILDAY
Press numeric keys from the key pad to set the desired time in 24 hour
HH:MM format.
(Press NEXT to move to the next digit after entering each digit)
Use FULL and PART keys to toggle between ENABLE and DISABLE. This
will either enable or disable automatic arming.
Press ENTER to confirm
23
2-9-2 DISARMING TIME
GALAXY
AUTO OPERATION
1-ARMING TIME
2-DISARMING TIME
3-SET HOLIDAY
GALAXY
AUTO OPERATION
1-ARMING TIME
2-DISARMING TIME
3-SET HOLIDAY
SET HOLIDAY
DAY STATUS
SUNDAY DISABLE
24
GALAXY 4016 GSM
25
2-11 BUTTONS ON THE KEY PAD
26
GALAXY 4016 GSM
3-1 FULL ARM THE SYSTEM
<ARM><SPACE><END>
Example: 1
1234 FULL ARM END
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
system.
<END>
Example: 1
1234 DISARM END
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
system.
<ADMIN CODE><SPACE><CHANGE><SPACE>
<CODE><ENTER><#XXXX-YYYY*><SPACE><END>
2 3
†
4 5 6 7 8 9 0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
is 5678.
27
3-4 CHANGE DELAY TIME
<ADMIN CODE><SPACE><ENTRY><SPACE>
<TIME><SPACE><#XXX*><SPACE><END> New message
CONTROL PANEL NUMBER
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
to 120 seconds.
<ADMIN CODE><SPACE><EXIT><SPACE>
<TIME><SPACE><#XXX*><SPACE><END>
New message
CONTROL PANEL NUMBER
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
35 seconds.
<ADMIN CODE><SPACE><SOUNDER><SPACE>
<TIME><SPACE><#XX*><SPACE><END>
New message
CONTROL PANEL NUMBER
@
X C
ENTER
V B N M
.
³
8
time to 04 minutes.
28
GALAXY 4016 GSM
3-6 SET AUTO OPERATION
<ADMIN CODE><SPACE><AUTO><SPACE>
<ARM><SPACE><#HH:MM*><SPACE><XXX>
<SPACE><END>
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
<ADMIN CODE><SPACE><AUTO><SPACE>
<DISARM><SPACE><#HH:MM*><SPACE>
<XXX><SPACE><END>
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
29
3-6-3 SET HOLIDAY
<ADMIN CODE><SPACE><SET><SPACE>
<HOLIDAY><SPACE><#XXX*><SPACE><YYY>
<SPACE><END>
A
W
S
E
D
R
F
T
G
Y
H
U
J
I
K
O
I
P
<ADMIN CODE><SPACE><SCHEDULE>
<SPACE><CHANGE><#XX-SS:TT,HH:MM,A,B*>
<SPACE><END>
XX = ZONE NO
SS:TT = Start time in HH:MM (24 hour format)
HH:MM = End time in HH:MM (24 hour format)
A = Sounder Enable / Disable
N = Sounder Enable
Y = Sounder Disable
B = Schedule Enable / Disable
N = Schedule Enable
New message
Y = Schedule Disable
CONTROL PANEL NUMBER
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
<ADMIN CODE><SPACE><TEL><SPACE>
<NO><SPACE><INTRUSION><SPACE><#YY-
XXXXXXXXXX*><SPACE><END>
@
X C
ENTER
V B N M
.
³
8
<ADMIN CODE><SPACE><TEL><SPACE>
<NO><SPACE><INTRUSION><#XX-REMOVE*>
<SPACE><END>
New message
CONTROL PANEL NUMBER
@
X C
ENTER
V B N M
.
³
8
31
REMOVE ALL SAVED TELEPHONE NUMBER IN INTRUSION
This option is used to remove all saved telephone number in
intrusion.
New message
<ADMIN CODE><SPACE><INTRU><SPACE> CONTROL PANEL NUMBER
<CLEAR><SPACE><END>
1234 INTRU CLEAR
Example: 1
END
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
in intrusion.
<ADMIN CODE><SPACE><TEL><SPACE>
<NO><SPACE><FIRE><SPACE><#YY-
XXXXXXXXXX*><SPACE><END>
New message
YY = Phone no. location (01, 02, 03…….10) CONTROL PANEL NUMBER
@
X C
ENTER
V B N M
.
³
8
<ADMIN CODE><SPACE><TEL><SPACE>
<NO><SPACE><FIRE><#XX-REMOVE*>
<SPACE><END> New message
CONTROL PANEL NUMBER
A S D F G H J K I
<CLEAR><SPACE><END>
@
X C
ENTER
V B N M
.
³
8
in fire.
£ Z X C V B N M ³
electronics) be incorporated in all SMS sent by the 123 @ ENTER .
8
panel.
<ADMIN CODE><SPACE><ALARM><SPACE>
<RESET><SPACE><END> 1234 ALARM RESET
END †
1 2 3 4 5 6 7 8 9 0
Q W E R T Y U I O P
Example: A S D F G H J K I
£
Refer to the illustration of the mobile phone screen ³
Z X C V B N M
123 @ ENTER .
8
33
3-11 SOUNDER STOP
<ADMIN CODE><SPACE><SOUNDER>
<SPACE><OFF><SPACE><END> 1234 SOUNDER OFF
END †
1 2 3 4 5 6 7 8 9 0
Q W E R T Y U I O P
Example: A S D F G H J K I
£
Refer to the illustration of the mobile phone screen ³
Z X C V B N M
123 @ ENTER .
8
<INT><SPACE><MSG><SPACE><END>
1234 RECO INT MSG
Example: 1
END
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
message command.
34
GALAXY 4016 GSM
3-12-2 RECORD FIRE VOICE MESSAGE
<FIRE><SPACE><MSG><SPACE><END>
1234 RECO FIRE MSG
Example: 1
END
2 3
†
4 5 6 7 8 9 0
Q W E R T Y U I O P
message command.
<INT><SPACE><MSG><SPACE><END>
1234 PLAY INT MSG
Example: 1
END
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
message command.
35
3-13-2 PLAY FIRE VOICE MESSAGE
This function allows the user to listen to the recorded fire voice
message.
<FIRE><SPACE><MSG><SPACE><END>
1234 PLAY FIRE MSG
Example: 1
END
2 3 4 5 6 7 8 9
†
0
Q W E R T Y U I O P
@
X C
ENTER
V B N M
.
³
8
command.
If the user has FORGOTTEN the ADMIN CODE, the panel has to be
reset to FACTORY SETTINGS.
1- PREVIOUS
SETTING
2- FACTORY
SETTING
36
GALAXY 4016 GSM
Press 2
The panel will reset to factory settings and the ADMIN CODE will be
reset to 1234.
Note: The programmed messages and telephone numbers stored in
the panel will not be erased when the panel is reset to factory settings.
In order to make it easier to operate the control panel, both the key pad
buttons and the LCD screen are fully backlit. The keypad and LCD screen
will illuminate if a button is pressed or any delay zone is opened. The lights
switch off automatically after one minute.
As an additional safety feature, the control panel has one mains AC fuse
on the power supply card and two safety fuses on the battery charging
board. In the event of an overload in the power supply, sounder or auxiliary
supply circuits, a fuse will blow. This fuse must be replaced.
The control panel has a unique optional feature of retrieving the previous
settings in case of complete power failure. In case of complete power
failure (AC and battery), when the system restarts, an option to retrieve
previous settings or to reset to factory settings is given.
Following information is retrieved in this case:
1. Arm or Disarm status
2. Admin Code
3. Entry, Exit and Sounder time
4. Automatic Arming Time
5. Holiday setting
6. Intrusion Log
37
5-6 UNIQUE BYPASS FEATURE OF 24 HOUR ACTIVE ZONE
GALAXY
38
GALAXY 4016 GSM
6 - TECHNICAL SPECIFICATIONS
ELECTRICAL
REMOTE KEY PAD ONLY
Quiescent current : 30 mA Max.
Quiescent current with backlit LCD : 90 mA Max.
POWER SUPPLY
Mains supply Voltage : 220+10%-15% 50Hz
Total current Output : 2A at 220V AC or 4A at 220V AC
Battery Voltage : 12V DC
Battery type : SMF Rechargeable
Battery Recharge Voltage : 13.8V +/-0.2V DC
ENVIRONMENTAL
ELECTRICAL
REMOTE KEY PAD ONLY
Quiescent current : 30 mA Max.
Quiescent current with backlit LCD : 90 mA Max.
39
6 - TECHNICAL SPECIFICATIONS
POWER SUPPLY
Mains supply Voltage : 220+10%-15% 50Hz
Total current Output : 2A at 220V AC or 4A at 220V AC
Battery Voltage : 12V DC
Battery type : SMF Rechargeable
Battery Recharge Voltage : 13.8V +/-0.2V DC
ENVIRONMENTAL
Operating Temperature : 0C to 45C
Storage Temperature : -20C to 60C
PHYSICAL
REMOTE KEY PAD
Dimensions : 310mm x 315mm x 100mm
MAIN CONTROL STATION
Dimensions : 258mm x 230mm x 76mm
Max Battery Dimensions : 150mm x 110mm x 64mm
40
GALAXY 4016 GSM
GSM
GSM Frequency : Dual Band 900MHz / 1800 MHZ
Safety Precaution:
Your cellular device receives and transmits radio frequency energy while
switched on and while making receiving calls. Remember that interference
can occur if it is used close to TV sets, radio, computers or inadequately
shielded equipment.
IMPORTANT!
Cellular devices using radio signals and cellular networks. Because of this,
connection cannot be guaranteed at all times under all conditions.
Remember, in order to make or receive calls, the cellular device must be
switched on and in a service area with adequate cellular signal strength.
41
TAMPER
SWITCH
ZONE CARD - 33 to 40 ZONE CARD - 25 to 32 ZONE CARD ZONE CARD - 9 to 16
- 17 to 24
LL
ZONE CARD - 1 to 8
BATTERY
CHARGING
BOARD MCU CARD
BATTERY MIC
SPEAKER
SOUNDER
ANTENNA
RELAY CARD
AC 220V
GSM CARD
REMOTE KEY PAD
SMPS CARD
42
Integrated Intruder Alarm Fire Alarm
Security Systems Systems Systems
(
GSM & PSTN Monitoring CCTV
Dialers Services Surveillance
w w w. s e c u r i c o e l e c t r o n i c s . c o m