Room Air Conditioner: SVC MANUAL (Exploded View)

The document is a service manual that provides specifications and diagrams for an LG room air conditioner model TS-C1825DA1. It contains: 1. Specifications for the unit including cooling/heating capacity, electrical information, performance data, dimensions, and included features. 2. Diagrams of the indoor and outdoor unit piping layout. 3. Wiring diagrams of the indoor and outdoor units showing the electrical components and connections. The service manual provides technicians with the necessary technical details and diagrams to properly service the LG room air conditioner. It outlines the unit specifications, piping configuration, electrical components, and wiring diagrams.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
302 views8 pages

Room Air Conditioner: SVC MANUAL (Exploded View)

The document is a service manual that provides specifications and diagrams for an LG room air conditioner model TS-C1825DA1. It contains: 1. Specifications for the unit including cooling/heating capacity, electrical information, performance data, dimensions, and included features. 2. Diagrams of the indoor and outdoor unit piping layout. 3. Wiring diagrams of the indoor and outdoor units showing the electrical components and connections. The service manual provides technicians with the necessary technical details and diagrams to properly service the LG room air conditioner. It outlines the unit specifications, piping configuration, electrical components, and wiring diagrams.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

http://biz.lgservice.

com

Room Air Conditioner


SVC MANUAL(Exploded View)
MODEL : TS-C1825DA1

CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
1. Specification
Product Model TS-C1825DA1
Sales Model SJ182CD
Capacity
Cooling Capacity Btu/h 18000
Heating Capacity Btu/h -
Electrical Parts
Voltage. Frequency/Phase Φ / V / Hz 1,220V,60Hz
Power Input Cooling W 1800
Heating W -
Running Current Cooling A 8.4
Heating A -
Performance
EER Cooling Btu/h 10.0
COP Heating W/W -
Air Circulation Indoor,Max ㎥/min(cfm) 13.0
Outdoor,Max ㎥/min(cfm) 28
Moisture Removal l/h 2.5
Sound Level Indoor,H/M/L dB(A)+3 42
Outdoor,Max dB(A)+3 56
Feature
Neo Plasma Air Purifying System N
Anti Corrasion N
Temperature Control Y
CHAOS Wind(Auto Wind) N
Airflow Direction Control(up&down) Auto
Airflow Direction Control(left&right) Manual
Remocon Type Wireless Simple
Setting Temperature Range Cooling 18-30
Heating -
Auto Chage Over N
Auto Clean N
Seps,Fan/Cool 3/4
o
Temperature Increment 1 C
Timer 7Hr,Off
Sleep Operation Y
Restart Delay(Minute) 3
Hot start -
Jet Cool Y
Compressor Type Rotary,PH250(Toshiba)
Installation & Stuffing
Net Dimensions WxHxD mm 1090*314*190/770*540*245
Net Weight Indoor/Outdoor kg 14/41
Q'ty With S/parts 20/40FT
Without S/parts 20/40FT

Note: Some of functions are slightly different depending upon models.


O : Applied, - : No relation The specification may be subject to change without prior notice for purpose of
* For circuit breaker rating, please conform to local standards wherever necessary. improvement.

2 Room Air Conditioner


2. Piping Diagrams
Indoor Unit Outdoor Unit

Liquid Side Capillary Tube

2-Way Valve
Th2

Th1

Heat Heat
Exchanger Exchanger
(Evaporator) (Condenser)

Compressor
Gas Side

Accumulator
3-Way Valve
High Pressure S/W

Cooling

LOC. Description PCB Connector


Th1 Thermistor for indoor air temperature
CN-TH1
Th2 Thermistor for evaporating temperature

Service Manual 3
3. Wiring Diagrams
Indoor Unit

GN/YL
BR
BL

1(L)2(N) 3
GN/YL
BR
BL

3854A23009

CN-U/D
RY-COMP CN-HVB
RY-COMP4 CN-DISP2

FUSE
CN-N2

CN-N1

CN-MOTOR

4 Room Air Conditioner


Outdoor Unit

BLUE

CAPACITOR
RED H C F RED

R S BLUE BLUE

OVERLOAD
PROTECT
C

FAN

YELLOW
BROWN

BLUE

YELLOW/GREEN

TERMINAL BLOCK 1(L) 2(N)


BLUE
BROWN

THE UNIT INDOOR

OUTDOOR DIAGRAM WIRING


EBY36312302

Capacitor
Terminal Block

Service Manual 5
Exploded View

Exploded View
1. Indoor Unit
135316

152302
135313

131410 733010

342800

359011
135311
354210

147581

352115
35211B 346810

268711A 352116 135516

268711D
352150

W0CZZ

146811

267110 249951

6 Room Air Conditioner


Exploded View

Exploded View
Outdoor Unit 554031
437212

552112
435512

552111
649950

549610
435511
559010

546810

435301 447910

554160
552203-1
550140

430410

437210 552203-2

Service Manual 7
P/NO : MFL37322726 JANUARY, 2008