Trox SDRF
Trox SDRF
Trox SDRF
Screw fixing
Type Page
SDRF General information SDRF – 2
Function SDRF – 3
Technical data SDRF – 6
Quick sizing SDRF – 7
Specification text SDRF – 8
Order code SDRF – 9
Variants SDRF – 10
Dimensions and weight SDRF – 11
Product details SDRF – 13
Installation examples SDRF – 14
Installation details SDRF – 15
Basic information and nomenclature SDRF – 17
②
①
③
⑥
④
⑤
A
B
①
②
①
②
Sizing example
Given data
= 15 l/s (54 m3/h)
Staircase swirl diffuser
Maximum sound power level 35 dB(A)
Quick sizing
Type SD
Variants: SD-Q-LQ, SD-Q-LR
Type SDRF
Nominal sizes: SDRF/4, SDRF/5
Selected: SDRF/4
Staircase swirl diffusers with rectangular or – Cup made of ABS plastic, UL 94, V-0, flame
circular diffuser face and fixed air control blades retardant
for swirling supply air discharge creating high – Cup similar to RAL 9005, black
induction levels. For supply air only; for comfort – Exposed diffuser face powder-coated
conditioning applications. For installation into the RAL 9005, jet black
risers of steps. – P1: Powder-coated, RAL CLASSIC colour
Ready-to-install component which consists of a
diffuser face with up to six outlets. Each outlet with Technical data
radially arranged fixed blades and a cup with – Nominal sizes: 1, 2, 3, 4, 5 or 6 outlets
damper element. – Minimum volume flow rate: 2 – 12 l/s or
Diffuser face with fixing screws (concealed with 7 – 43 m³/h
decorative caps) or with spring clip fixing. – Maximum volume flow rate: 5 to 25 l/s or
Sound power level of the air-regenerated noise 18 to 90 m³/h
measured according to EN ISO 5135. – Supply air to room air temperature difference:
–6 to +6 K
Special characteristics
– High induction results in a rapid reduction of Sizing data
the temperature difference and airflow velocity – _____________ _______________________
– Air discharge parallel to the installation surface [m³/h]
– Excellent air quality since the supply air is – Δpt____________ _______________________
discharged directly to the occupied zone [Pa]
– Vertical installation into steps Air-regenerated noise
– LWA____________ _______________________
Materials and surfaces [dB(A)]
– Diffuser face made of sheet steel
SDRF
SDRF-K/5 SDRF-K/6
SDRF-K/1
44
8
Ø80
SDRF-S/1
Ø64
55
43
8
Ø80
SDRF-*/1
m
Nominal size
kg
1 0.10
70
C A A C
44
8
L
70
C A A C
44
8
12
SDRF
L A C m
Nominal size
mm mm mm kg
2 200 74 63 0.15
3 300 87 63 0.25
4 400 86 71 0.35
5 500 92 66 0.45
6 500 74 65 0.50
Ø55
3 0.001878
4 0.002504
5 0.003130
Ø80 6 0.003756
SDRF-1, vertical installation into steps SDRF-3, vertical installation into steps
Ø68
Ø68
68
L – 44
Ø64
64
L – 44
12
LWA [dB(A)] Δpt [Pa]
A-weighted sound power level of air-regenerated Total differential pressure
noise
Aeff [m²]
[m³/h] and [l/s] Effective air discharge area
Volume flow rate
All sound power levels are based on 1 pW.
Δtz [K]
Supply air to room air temperature difference, i.e.