Specification and Inspection Criteria for Tubes:
Dimensional Characteristics
Seite 1 von 6 Version S-101-05 Index: C (May 2014)
Application: This specification and inspection criteria is applicable for direct drawn
ilmasil fused quartz tubes
1 Outer diameter (OD)
Definition: all outside diameter in all cross-sectional planes along the tube length, measured
rectangular to the tube axis.
Tolerance: enclosure 1 or as specified
Tested by: caliper gauge
2 Inner diameter (ID)
Definition: inside diameter the cross-sectional planes of both tube ends; to measure rectangular to
the tube axis
Tolerance: no criteria unless specified in drawing and/or order.
Tested by: caliper gauge, plug gauge
3 Wall thickness (wt)
Definition: wall thickness to measure rectangular to the tube axis on all positions of cross section
on both ends
Tolerance: Wall Thickness ≤ 2 mm: ± 0.2 mm
Wall Thickness > 2 mm: ± 10% of nominal wall thickness
Tested by: caliper gauge, micrometer, ultrasonic wall thickness gauge
Remark: Due to technological reasons only combinations of two sizes can be accepted.
The size range of the third size results from the nominal sizes / tolerances.
Possible Combinations:
Tolerances for OD / wt → ID without tolerance (preferred combination)
Tolerances for ID / wt → AD without tolerance
Tolerances for OD / ID → WT without tolerance
QSIL GmbH Quarzschmelze Ilmenau – Gewerbering 8 – 98704 Langewiesen / Germany Page: 1/6
Specification and Inspection Criteria for Tubes:
Dimensional Characteristics
Seite 2 von 6 Version S-101-05 Index: C (May 2014)
4 Siding (SD)
Definition: difference between largest and smallest wall thickness of cross sections, measured
on both ends rectangular to the tube axis
Tolerance: max. 50% of tolerance for wall thickness
Tested by: caliper gauge, micrometer, ultrasonic wall thickness gauge
5 Ovality (OVA)
Definition: Difference between largest and smallest outside diameter at any cross section,
anywhere along or around the tube
Tolerance:
OD in mm Maximum Ovality in mm
> 0.4 - 3 0.1
> 3-5 0.2
Max. OD – Min. OD x 100 %
Nominal OD
OD in mm Maximum Ovality in %
OD : ID < 1.7 OD : ID = 1.7...2.5 OD : ID > 2.5
> 5 - 10 2.0 3.0 5
> 10 - 16 1.5 2.5 5
> 16 - 35 1.0 2.0 5
> 35 - 65 1.0 1.5 -
Tested by: caliper gauge
QSIL GmbH Quarzschmelze Ilmenau – Gewerbering 8 – 98704 Langewiesen / Germany Page: 2/6
Specification and Inspection Criteria for Tubes:
Dimensional Characteristics
Seite 3 von 6 Version S-101-05 Index: C (May 2014)
6 Length (L)
6.1. Ends furnace cut (fc)
Definition: usable length, if tube is to cut to rectangular ends
Tolerance: +20 mm / - 0 mm related to the nominal length
Tested by: Ruler or measuring tape
Remark: tube to be scratched and broken. Ends may have non-rectangular sharp ends, splinters
and tips.
6.2. Ends trim cut (tc)
Definition: Length between both ends
Tolerance:
tube length Tolerance
[mm] [mm]
30 - 299 ±1
300 - 599 ± 1.5
600 - 999 ± 3.0
Tested by: Ruler, measuring tape, caliper gauge
Remark: tube to be scratched and broken. Ends may have splinters and tips.
6.3 Ends saw cut (sc)
Definition: Length between both ends
Tolerance:
Tube length OD ≤ 30 mm OD > 30 mm
[mm]
30 - 299 ± 0.5 ±1.0
300 - 599 ± 1.0 ±1.5
600 - 999 ± 2.0 ±3.0
1000- 2499 ± 3.0 ±4.0
2500 - 4000 ± 4.0 ±5.0
Tested by: Ruler, measuring tape, caliper gauge
Remark: tube to be cut by cutting disk
QSIL GmbH Quarzschmelze Ilmenau – Gewerbering 8 – 98704 Langewiesen / Germany Page: 3/6
Specification and Inspection Criteria for Tubes:
Dimensional Characteristics
Seite 4 von 6 Version S-101-05 Index: C (May 2014)
7 Bow
Definition: Maximum deviation from the ideal centre line between both ends.
maximum gap
Tube length
Tolerance: 1,5 mm/m
Tested by: Tube is placed on a straight plate, bow is tested by measuring the distance between plate
and tube surface by feeler gauge. The maximum gap between plate and tube surface to
be calculated:
l2
x = [ r − r 2 − ] ∗ 1000
4
x – max. gap in mm
r – radius of curvature in m
l – tube length in m
Maximum gap in mm related to the tube length:
tube length max. gap tube length max. gap tube length max. gap
[m] [mm] [m] [mm] [m] mm]
0.5 0.3 1.2 2.1 1.9 5.4
0.6 0.5 1.3 2.5 2.0 6.0
0.7 0.7 1.4 2.9 2.1 6.6
0.8 0.9 1.5 3.3 2.2 7.2
0.9 1.2 1.6 3.8 2.3 7.9
1.0 1.5 1.7 4.3 2.4 8.6
1.1 1.8 1.8 4.8 2.5 9.3
Remark: not valid for tubes with bowing under dead load
QSIL GmbH Quarzschmelze Ilmenau – Gewerbering 8 – 98704 Langewiesen / Germany Page: 4/6
Specification and Inspection Criteria for Tubes:
Dimensional Characteristics
Seite 5 von 6 Version S-101-05 Index: C (May 2014)
8 Taper
Definition: difference between the largest and smallest outer diameters. measured anywhere along
or around the tube
Tolerance: max. 50% of tolerance for outer diameter (OD)
Tested by: caliper gauge
9 Cutting Irregularities
9.1 angularity of tube ends
Definition: angel between cross section and axial outer surface shell
Tolerance Inspection by
furnace cut end (fc) Not specified -
trim cut ends (tc) Not specified -
saw cut ends (sc) Max. 1° angle meter
9.2 Chipping
Tolerance Inspection by
furnace cut end (fc) Not specified -
trim cut ends (tc) Not specified -
max. 1/4 of wall thickness
saw cut ends (sc) Visual / caliper gauge
max. 1.5 mm along tube
9.3 Roughness of cross sections
Tolerance Inspection by
furnace cut end (fc) Not specified -
trim cut ends (tc) Not specified -
saw cut ends (sc) max. Ra 2.5 µm roughness measuring device
9.4 Flatness
Tolerance Inspection by
furnace cut end (fc) Not specified -
trim cut ends (tc) Not specified -
saw cut ends (sc) max. 0.5 mm feeler gauge
QSIL GmbH Quarzschmelze Ilmenau – Gewerbering 8 – 98704 Langewiesen / Germany Page: 5/6
Specification and Inspection Criteria for Tubes:
Dimensional Characteristics
Seite 6 von 6 Version S-101-05 Index: C (May 2014)
10 Other applicable documents
S-101-01 Specification of base materials
11 Attachment
Outer Diameter Tolerances
Outer Diameter (OD) Tolerance Outer Diameter (OD) Tolerance
[mm] [mm] [mm] [mm]
0.5 ± 0.1 18 ± 0.5
1 ± 0.1 20 ± 0.5
2 ± 0.1 22 ± 0.6
3 ± 0.2 23 ± 0.6
4 ± 0.2 24 ± 0.6
5 ± 0.2 25 ± 0.6
6 ± 0.2 26 ± 0.7
7 ± 0.3 28 ± 0.8
8 ± 0.3 30 ± 0.8
9 ± 0.3 35 ± 0.9
10 ± 0.3 40 ± 1.2
11 ± 0.3 45 ± 1.5
12 ± 0.4 50 ± 2.0
13 ± 0.4 55 ± 2.0
14 ± 0.4 60 ± 2.0
15 ± 0.4 65 ± 2.0
16 ± 0.5 70 ± 2.5
18 ± 0.5 75 ± 2.5
20 ± 0.5 80 ± 3.0
QSIL GmbH Quarzschmelze Ilmenau – Gewerbering 8 – 98704 Langewiesen / Germany Page: 6/6