DRT Report of 2-0700-CL-21 2019

Download as pdf or txt
Download as pdf or txt
You are on page 1of 49

Direct Radiography Testing SGS QATAR WLL

Building No : ELG CC48


Plot No- SS 24A. West Support Service Area (WSSA),
OF Ras Laffan Industrial City
P. O. Box 24140
FGP-2 Exit 66 on Shamal Road,
Tel +974 4036 2700
Fax+974 4036 2710
2-0700-CL-21
FOR
FINAL REPORT
Qatar Shell GTL, RASLAFFAN
September-2019

Client : Qatar Shell GTL

Client Representative : Mr. Vijaianand Kaliyaperumal

SGS Ref. No. : 50001968

Report No. : DR-QSGTL-SGS-431

Corrosion Loop No. : 2-0700-CL-21

Conducted by : Veera Salvam

Reviewed by : Mazhar Ali


SGS Qatar has reviewd “Report No. DR-QSGTL-SGS-431 and found
Reviewed Comments :
satisfactory as per client’s requirements.

Prepared by Reviewed by

Mc Delan Razon Mazher Ali


CRT Specialist Sr.Inspection Engineer

This document is issued by the Company under its General Conditions of Service accessible at
http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues
defined therein.
Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not
exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest
extent of the law.
Any holder of this document is advised that the information contained hereon is limited to visual examination of the safely and readily
accessible portions of the consignment only
Direct Radiography Test

Doc. No. DR-QSGTL-SGS-431


Inspection Technology W.L.L.
Line No. FGP-02 2-0700-CL-21
Project Name: QSGTL P.O. #: 131700169
Acceptance/Evaluation Criteria As per client
Procedure RT/CR-0307-02
Film Type DR Panel Detector
Equipment/Sr. No. GE ® DXR250C-W/Sr. # VA25769-4D

Component Information
Component ID 2-0700-CL-21
Company Name SGS
Remarks N/A
Approver name SGS Representative
Approve Date 02-SEPT-2019
Modified Date 02-SEPT-2019
Modified by CZC0131V8P\GESIT Rhythm
Technique Information
SETUP DIAGRAM
Kv 0.00
Ma 0.00
Exposure (s) 25 s.
Source Distance 28 inches
Source Type IR-192
Curie Strength 18.0 Ci
Focal Spot (mm) 2 x 3mm
Geometric Enlargement 1.00
Pipe Thickness --
Technique Description Profile
Date Modified 02-SEPT-2019
Modified By CZC0131V8P\GESIT Rhythm
IQI Type: --
IQI Size: --
IQI Material: --
Filter Material: --
Filter Thickness: 0.00

DR-GTL-SGS-431
Direct Radiography Test

Summary of DRT for FGP 02 2-0700-CL-21


Nomin
Dia al Minimum Maximum
Location
CML No Thickn Thicknes Thickness Observation Remarks
Type DN ess s (mm) (mm)
(mm)
CS-01P- NA 5.95 7.71 No sign of CS
REDUCER
P001 corrosion
CS-01P- NA 5.54 6.15 No sign of CS
ELBOW
P002 corrosion
CS-01P- NA 10.67 10.81 No sign of CS
DRAIN
P003 corrosion
CS-01P- PIPE NA 5.45 5.50 No sign of CS
P004 corrosion
CS-01P- ELBOW NA 5.51 6.29 No sign of CS
P005 corrosion
CS-01P- NA 5.82 7.57 No sign of CS
TEE
P006 corrosion
PWHT-CS- NA 5.86 11.15 No sign of PWHT
REDUCER
01P-P005 corrosion
PWHT-CS- NA 5.47 6.15 No sign of PWHT
ELBOW
01P-P006 corrosion
PWHT-CS- NA 6.87 7.21 No sign of PWHT
DRAIN
01P-P007 corrosion
PWHT-CS- N/A 5.22 6.90 No sign of PWHT
ELBOW
01P-P010 corrosion
PWHT-CS- N/A 10.74 10.85 No sign of PWHT
DRAIN
01P-P010 corrosion

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-CS-01P-P001


REDUCER DN- Nominal Thickness :
Min. Reading (5.95 ±0.17mm) ~ Max. Reading (7.71 ±0.17mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-CS-01P-P002


ELBOW Nominal Thickness :
Min. Reading (5.54 ±0.23mm) ~ Max. Reading (6.15 ±0.16mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-CS-01P-P003


DRAIN Nominal Thickness :
Min. Reading (10.67 ±0.38mm) ~ Max. Reading (10.81 ±0.26mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-CS-01P-P004


PIPE Nominal Thickness :
Min. Reading (5.45 ±0.17mm) ~ Max. Reading (5.50 ±0.17mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-CS-01P-P005


ELBOW Nominal Thickness :
Min. Reading (5.51 ±0.49mm) ~ Max. Reading (6.29 ±0.16mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-CS-01P-P006


TEE Nominal Thickness :
Min. Reading (5.82 ±0.29mm) ~ Max. Reading (7.57 ±0.21mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-PWHT-CS-01P-P005


REDUCER Nominal Thickness :
Min. Reading (5.86 ±0.29mm) ~ Max. Reading (11.15 ±0.16mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-PWHT-CS-01P-P006


ELBOW Nominal Thickness :
Min. Reading (5.47 ±0.18mm) ~ Max. Reading (6.15 ±0.18mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-PWHT-CS-01P-P007


DRAIN Nominal Thickness :
Min. Reading (6.87 ±0.18mm) ~ Max. Reading (7.21 ±0.18mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-PWHT-CS-01P-P010


ELBOW Nominal Thickness :
Min. Reading (5.22 ±0.21mm) ~ Max. Reading (6.90 ±0.20mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

DR results for QSGTL/ FGP1 –CL21-PWHT-CS-01P-P011


DRAIN Nominal Thickness :
Min. Reading (10.74 ±0.17mm) ~ Max. Reading (10.85 ±0.17mm)
No Sign of Corrosion
Reference Object/Size: Ball Bearing 25mm

DR-GTL-SGS-431
Direct Radiography Test

Prepared by: Mc Delan Razon Reviewed by: Approved by:

Signature: Signature: Signature:

I-Tech Inspector
SGS QSGTL

Date: 02-SEPT-2019
Date: Date:

DR-GTL-SGS-431
Corrosion Loop Pack for 1/2-0700-CL21

Equipment description: N/A

Tag/Item number(s): N/A

Sam Naonori Mitsuyoshi


C 28 Sep 11
Mohan Sonehara Ninomiya
IAB Issued for As - Built
Sam Naonori Mitsuyoshi
B 20 Nov 09
Mohan Sonehara Ninomiya
RIC Issued for Construction – Updated
Mizanur Naonori Mitsuyoshi
A 02 July 09
Rahman Sonehara Ninomiya
RFC Released for Construction
Mizanur Naonori Mitsuyoshi
O 2 Apr 09
Rahman Sonehara Ninomiya
ICC Issued for Company Comment
Rev. Date By Chkd Appr. Status Revision reason for issue description
Shell Project No.: HP-3000-QAT Contractor name: Unit:
Contractor Project No.: 5887 CHIYODA-HHI CONSORTIUM 1/2-0700
Contractor Contract No.: PI-096 Sheet: 1 of 34 PCWBS: JB,KB

PEARL GTL PROJECT Orig. Org.: Contractor Doc No: NA (QPG Job No. 51505)
QATAR CHC Project Doc No: T-4.091.106 Rev.: C
T-4.091.106 RevC - Corrosion Loop Pack for 1/2-0700-CL21
This document is confidential. Neither the whole nor any part of this document may be disclosed to any third party without the prior written consent of CHIYODA-HHI
CONSORTIUM (CHC). Title in respect of this document is vested in Qatar Shell GTL Limited. Neither the whole nor any part of this document may be reproduced, stored in
any retrieval system or transmitted in any form or by any means (electronic, mechanical, reprographic, recording or otherwise) without the prior consent of CHC.
Revision List

The following summarizes revisions to Document Number: T-4.091.106, Rev.C from Rev.O.

1. IDMS loader number is added on snapshot.

2. Flow direction is added on control valve.

3. For Piping 1-0700-CL21 (CS), 1 CML each is assigned for baseline thickness
measurement at site for Phase 1 and Phase 2 in accordance with the calculation using
IDMS loader reflecting the content of PI- 096- PMC-CHC-LE-04220 from QSGTL.

4. For Piping 1-0700-CL21 (PWHT CS), 2 CMLs each are assigned for baseline thickness
measurement at site for Phase 1 and Phase 2 in accordance with the calculation using
IDMS loader reflecting the content of PI- 096- PMC-CHC-LE-04220 from QSGTL.

5. For Piping 1-0700-CL21 (SS), 1 CML each is assigned for baseline thickness
measurement at site for Phase 1 and Phase 2 in accordance with the calculation using
IDMS loader reflecting the content of PI- 096- PMC-CHC-LE-04220 from QSGTL.

Shell Project No.: HP-3000-QAT Contractor name: Unit:


Contractor Project No.: 5887 CHIYODA-HHI CONSORTIUM 1/2-0700
Contractor Contract No.: PI-096 Sheet: 2 of 34 PCWBS: JB,KB

PEARL GTL PROJECT Orig. Org.: Contractor Doc No: NA (QPG Job No. 51505)
QATAR CHC Project Doc No: T-4.091.106 Rev.: C
T-4.091.106 RevC - Corrosion Loop Pack for 1/2-0700-CL21
This document is confidential. Neither the whole nor any part of this document may be disclosed to any third party without the prior written consent of CHIYODA-HHI
CONSORTIUM (CHC). Title in respect of this document is vested in Qatar Shell GTL Limited. Neither the whole nor any part of this document may be reproduced, stored in
any retrieval system or transmitted in any form or by any means (electronic, mechanical, reprographic, recording or otherwise) without the prior consent of CHC.
1. Introduction
This document provides the information of corrosion monitoring location (CML) on corrosion
loop 1/2-0700-CL21 in Unit 1/2-0700. This corrosion loop consists of two Trains, i.e. Train 1
(Phase-1) and Train 2 (Phase-2).

2. Corrosion Monitoring Location (CML)

There are three piping groups in this corrosion loop: Piping 1-0700-CL21 (CS), Piping 1-0700-
CL21 (PWHT CS) and Piping 1-0700-CL21 (SS).

The number of CML for Piping 1-0700-CL21 (CS) is 7 in accordance with the calculation using
IDMS loader reflecting the content of PI-096-PMC-CHC-LE-04220 and 1 CML is assigned as
the CML for baseline thickness measurement at site for Phase 1 based on PI-096-PMC-CHC-
LE-04220. 1 CML is assigned as the CML for baseline thickness measurement at site for Piping
2-0700-CL21 (CS), too.

The number of CML for Piping 1-0700-CL21 (PWHT CS) is 17 in accordance with the
calculation using IDMS loader reflecting the content of PI-096-PMC-CHC-LE-04220 and 2
CMLs are assigned as the CML for baseline thickness measurement at site for Phase 1 based
on PI-096-PMC-CHC-LE-04220. 2 CMLs are assigned as the CML for baseline thickness
measurement at site for Piping 2-0700-CL21 (PWHT CS), too.

The number of CML for Piping 1-0700-CL21 (SS) is 1 in accordance with the calculation using
IDMS loader reflecting the content of PI-096-PMC-CHC-LE-04220 and 1 CML is assigned as
the CML for baseline thickness measurement at site for Phase 1 based on PI-096-PMC-CHC-
LE-04220. 1 CML is assigned as the CML for baseline thickness measurement at site for Piping
2-0700-CL21 (SS), too.

There is no equipment which should be monitored in this loop.

CML details are shown in Attachment -1.

Marked up PEFS (Attachment-2) is attached and snapshots (Attachment-3) are taken for
respective CMLs. CMLs for Train 2 are similar to Train 1, so snapshots for Train 1 shall be used
for Train 2 as a manner that line number and equipment number on snapshots (Train 1) are
read as that of Train 2.

Location Guidance of thickness measurement for Piping/Static Equipment is shown in


Attachment-4.

Attachments

Attachment-1: CML Details of Corrosion Loop 1/2-0700-CL21.


Attachment-2: Marked up PEFS
Attachment-3: Snapshots of 3D model
Attachment-4: Location Guidance of thickness measurement for Piping/ Static Equipment

Shell Project No.: HP-3000-QAT Contractor name: Unit:


Contractor Project No.: 5887 CHIYODA-HHI CONSORTIUM 1/2-0700
Contractor Contract No.: PI-096 Sheet: 3 of 34 PCWBS: JB,KB

PEARL GTL PROJECT Orig. Org.: Contractor Doc No: NA (QPG Job No. 51505)
QATAR CHC Project Doc No: T-4.091.106 Rev.: C
T-4.091.106 RevC - Corrosion Loop Pack for 1/2-0700-CL21
This document is confidential. Neither the whole nor any part of this document may be disclosed to any third party without the prior written consent of CHIYODA-HHI
CONSORTIUM (CHC). Title in respect of this document is vested in Qatar Shell GTL Limited. Neither the whole nor any part of this document may be reproduced, stored in
any retrieval system or transmitted in any form or by any means (electronic, mechanical, reprographic, recording or otherwise) without the prior consent of CHC.
Attachment 1
CML Details
Corrosion Loop 1/2-0700-CL21
Thickness Monitoring Points & Mark (Label)
Location
Piping Group CML ID (Circuit Name) Location Snapshot No Measurement (*2) Pipe Segment Number Remarks
(* 1) N or 12:00 E or 3:00 S or 6:00 W or 9:00 Guidance
Piping 1-0700-CL21 (CS) Piping 1-0700-CL21 ( CS) 01P-P-001 Reducer 10721012 ( No ) 12-001 3-001 6-001 9-001 P-5 50-1P070330-11042-S2-25MM Middle of reducer
( Phase 1) Piping 1-0700-CL21 ( CS) 01P-P-002 Elbow Center 10721013 ( No ) 12-002 3-002 6-002 9-002 P-4 50-1P070330-11042-S2-25MM
Piping 1-0700-CL21 ( CS) 01P-P-003 Piping (Drain) 10721014 Yes N-003 E-003 S-003 W-003 P-1 20-1P070330-11042-S2-25MM More than 25 mm from weld
Piping 1-0700-CL21 ( CS) 01P-P-004 Piping 10721018 ( No ) N-004 E-004 S-004 W-004 P-1 50-1P070330-11042-S2-25MM More than 25 mm from weld
Piping 1-0700-CL21 ( CS) 01P-P-005 Elbow Center 10721019 ( No ) 12-005 3-005 - 9-005 P-4 50-1P070330-11042-S2-25MM 6:00 is deleted due to pipe support.
Piping 1-0700-CL21 ( CS) 01P-P-006 Piping 10721025 ( No ) 12-006 3-006 6-006 9-006 P-1 50-1P070330-11042-S2-25MM More than 25 mm from weld
Piping 1-0700-CL21 ( CS) 01P-P-007 Reducer 10721002 ( No ) N-007 E-007 S-007 W-007 P-5 100-1P070328-11180Q1-S2-25MM Middle of reducer
Piping 1-0700-CL21 (PWHT CS) Piping 1-0700-CL21 (PWHT CS) 01P-P-001 Piping (Vent) 10721001 Yes 12-001 3-001 6-001 9-001 P-1 25-1P070328-11374-S2-25MM More than 25 mm from weld
( Phase 1) Piping 1-0700-CL21 (PWHT CS) 01P-P-002 Reducer 10721003 ( No ) N-002 E-002 S-002 W-002 P-5 80-1P070328-11374-S2-25MM Middle of reducer
Piping 1-0700-CL21 (PWHT CS) 01P-P-003 Piping (Vent) 10721004 ( No ) 12-003 3-003 6-003 9-003 P-1 20-1P070328-11374-S2-25MM More than 25 mm from weld
Piping 1-0700-CL21 (PWHT CS) 01P-P-004 Piping 10721005 ( No ) N-004 E-004 S-004 W-004 P-1 80-1P070328-11374-S2-25MM More than 25 mm from weld
Piping 1-0700-CL21 (PWHT CS) 01P-P-005 Reducer 10721006 ( No ) 12-005 3-005 6-005 9-005 P-5 25-1P070329-11374-S2-25MM Middle of reducer
Piping 1-0700-CL21 (PWHT CS) 01P-P-006 Elbow Center 10721007 ( No ) 12-006 3-006 6-006 9-006 P-4 25-1P070329-11374-S2-25MM
Piping 1-0700-CL21 (PWHT CS) 01P-P-007 Piping (Drain) 10721008 Yes N-007 E-007 S-007 W-007 P-1 20-1P070329-11374-S2-25MM More than 25 mm from weld
Piping 1-0700-CL21 (PWHT CS) 01P-P-008 Reducer 10721009 ( No ) 12-008 3-008 6-008 9-008 P-5 50-1P070328-11374-N-0MM Middle of reducer
Piping 1-0700-CL21 (PWHT CS) 01P-P-009 Piping 10721010 ( No ) N-009 E-009 S-009 W-009 P-1 150-1P070328-11374-N-0MM More than 25 mm from weld
Piping 1-0700-CL21 (PWHT CS) 01P-P-010 Elbow Center 10721011 ( No ) 12-010 3-010 6-010 9-010 P-4 25-1P070329-11374-S2-25MM
Piping 1-0700-CL21 (PWHT CS) 01P-P-011 Piping (Drain) 10721015 ( No ) N-011 E-011 S-011 W-011 P-1 20-1P070329-11374-S2-25MM More than 25 mm from weld
Piping 1-0700-CL21 (PWHT CS) 01P-P-012 Reducer 10721016 ( No ) 12-012 3-012 6-012 9-012 P-5 50-1P070329-11374-N-0MM Middle of reducer
Piping 1-0700-CL21 (PWHT CS) 01P-P-013 Elbow Center 10721017 ( No ) 12-013 3-013 6-013 9-013 P-4 50-1P070329-11374-N-0MM
Piping 1-0700-CL21 (PWHT CS) 01P-P-014 Elbow Center 10721020 ( No ) 12-014 3-014 6-014 9-014 P-4 40-1G070602-11374-N-0MM
Piping 1-0700-CL21 (PWHT CS) 01P-P-015 Joint 10721023 ( No ) - 3-015 6-015 9-015 P-1 150-1P070328-11374-N-0MM More than 25mm from weld
Piping 1-0700-CL21 (PWHT CS) 01P-P-016 Elbow Center 10721027 ( No ) 12-016 3-016 - 9-016 P-4 50-1P070329-11374-N-0MM 6:00 is deleted due to pipe support.
Piping 1-0700-CL21 (PWHT CS) 01P-P-017 Piping (Drain) 10221028 ( No ) N-017 E-017 S-017 W-017 P-1 20-1G070602-11374-N-0MM More than 25mm from weld.
Piping 1-0700-CL21 (SS) Piping 1-0700-CL21 (SS) 01P-P-001 Joint 10721026 Yes - 3-001 - 9-001 P-1 50-1P070718-13012Q1-S2-25MM More than 25mm from weld, 12:00 is deleted due to Joint & 6:00 is
Phase-1 deleted due to pipe support.
Piping 2-0700-CL21 (CS) Piping 2-0700-CL21 ( CS) 01P-P-001 Reducer (10721012) ( No ) 12-001 3-001 6-001 9-001 P-5 50-2P070330-11042-S2-25MM Middle of reducer
( Phase 2) Piping 2-0700-CL21 ( CS) 01P-P-002 Elbow Center (10721013) ( No ) 12-002 3-002 6-002 9-002 P-4 50-2P070330-11042-S2-25MM
*Snapshots of Phase-1 shall Piping 2-0700-CL21 ( CS) 01P-P-003 Piping (Drain) (10721014) Yes N-003 E-003 S-003 W-003 P-1 20-2P070330-11042-S2-25MM More than 25 mm from weld
be referred.
Piping 2-0700-CL21 ( CS) 01P-P-004 Piping (10721018) ( No ) N-004 E-004 S-004 W-004 P-1 50-2P070330-11042-S2-25MM More than 25 mm from weld
Piping 2-0700-CL21 ( CS) 01P-P-005 Elbow Center (10721019) ( No ) 12-005 3-005 - 9-005 P-4 50-2P070330-11042-S2-25MM 6:00 is deleted due to pipe support.
Piping 2-0700-CL21 ( CS) 01P-P-006 Piping (10721025) ( No ) 12-006 3-006 6-006 9-006 P-1 50-2P070330-11042-S2-25MM More than 25 mm from weld
Piping 2-0700-CL21 ( CS) 01P-P-007 Reducer (10721002) ( No ) N-007 E-007 S-007 W-007 P-5 100-2P070328-11180Q1-S2-25MM Middle of reducer
Piping 2-0700-CL21 (PWHT CS) Piping 2-0700-CL21 (PWHT CS) 01P-P-001 Piping (Vent) (10721001) Yes 12-001 3-001 6-001 9-001 P-1 25-2P070328-11374-S2-25MM More than 25 mm from weld
( Phase 2) Piping 2-0700-CL21 (PWHT CS) 01P-P-002 Reducer (10721003) ( No ) N-002 E-002 S-002 W-002 P-5 80-2P070328-11374-S2-25MM Middle of reducer
*Snapshots of Phase-1 shall Piping 2-0700-CL21 (PWHT CS) 01P-P-003 Piping (Vent) (10721004) ( No ) 12-003 3-003 6-003 9-003 P-1 20-2P070328-11374-S2-25MM More than 25 mm from weld
be referred.
Piping 2-0700-CL21 (PWHT CS) 01P-P-004 Piping (10721005) ( No ) N-004 E-004 S-004 W-004 P-1 80-2P070328-11374-S2-25MM More than 25 mm from weld
Piping 2-0700-CL21 (PWHT CS) 01P-P-005 Reducer (10721006) ( No ) 12-005 3-005 6-005 9-005 P-5 25-2P070329-11374-S2-25MM Middle of reducer
Piping 2-0700-CL21 (PWHT CS) 01P-P-006 Elbow Center (10721007) ( No ) 12-006 3-006 6-006 9-006 P-4 25-2P070329-11374-S2-25MM
Piping 2-0700-CL21 (PWHT CS) 01P-P-007 Piping (Drain) (10721008) Yes N-007 E-007 S-007 W-007 P-1 20-2P070329-11374-S2-25MM More than 25 mm from weld
Piping 2-0700-CL21 (PWHT CS) 01P-P-008 Reducer (10721009) ( No ) 12-008 3-008 6-008 9-008 P-5 50-2P070328-11374-N-0MM Middle of reducer
Piping 2-0700-CL21 (PWHT CS) 01P-P-009 Piping (10721010) ( No ) N-009 E-009 S-009 W-009 P-1 150-2P070328-11374-N-0MM More than 25 mm from weld
Piping 2-0700-CL21 (PWHT CS) 01P-P-010 Elbow Center (10721011) ( No ) 12-010 3-010 6-010 9-010 P-4 25-2P070329-11374-S2-25MM
Piping 2-0700-CL21 (PWHT CS) 01P-P-011 Piping (Drain) (10721015) ( No ) N-011 E-011 S-011 W-011 P-1 20-2P070329-11374-S2-25MM More than 25 mm from weld
Piping 2-0700-CL21 (PWHT CS) 01P-P-012 Reducer (10721016) ( No ) 12-012 3-012 6-012 9-012 P-5 50-2P070329-11374-N-0MM Middle of reducer
Piping 2-0700-CL21 (PWHT CS) 01P-P-013 Elbow Center (10721017) ( No ) 12-013 3-013 6-013 9-013 P-4 50-2P070329-11374-N-0MM
Piping 2-0700-CL21 (PWHT CS) 01P-P-014 Elbow Center (10721020) ( No ) 12-014 3-014 6-014 9-014 P-4 40-2G070602-11374-N-0MM
Piping 2-0700-CL21 (PWHT CS) 01P-P-015 Joint (10721023) ( No ) - 3-015 6-015 9-015 P-1 150-2P070328-11374-N-0MM More than 25mm from weld
Piping 2-0700-CL21 (PWHT CS) 01P-P-016 Elbow Center (10721027) ( No ) 12-016 3-016 6-016 9-016 P-4 50-2P070329-11374-N-0MM 6:00 is deleted due to pipe support.
Piping 2-0700-CL21 (PWHT CS) 01P-P-017 Piping (Drain) (10221028) ( No ) N-017 E-017 S-017 W-017 P-1 20-2G070602-11374-N-0MM More than 25mm from weld.
Attachment 1
Thickness Monitoring Points & Mark (Label)
Location
Piping Group CML ID (Circuit Name) Location Snapshot No Measurement (*2) Pipe Segment Number Remarks
(* 1) N or 12:00 E or 3:00 S or 6:00 W or 9:00 Guidance
Piping 2-0700-CL21 (SS) Piping 2-0700-CL21 (SS) 01P-P-001 Joint (10721026) Yes - 3-001 - 9-001 P-1 50-2P070718-13012Q1-S2-25MM More than 25mm from weld, 12:00 is deleted due to Joint & 6:00 is
Phase-2 deleted due to pipe support.
*Snapshots of Phase-1 shall
be referred.
(*1) - ' Yes ' : to be measured at site
(*1) - ' ( No ) ' : marking only on the 3D model
(*2) - Coloured column should be marked at site
Attachment-2
Attachment-3

CL21 ( CS) 01P-P-001


CL21 ( CS) 01P-P-002
CL21 ( CS) 01P-P-003
CL21 ( CS) 01P-P-004
CL21 ( CS) 01P-P-005
CL21 ( CS) 01P-P-006
CL21 ( CS) 01P-P-007
CL21 (PWHT CS) 01P-P-001
CL21 (PWHT CS) 01P-P-002
CL21 (PWHT CS) 01P-P-003
CL21 (PWHT CS) 01P-P-004
CL21 (PWHT CS) 01P-P-005
CL21 (PWHT CS) 01P-P-006
CL21 (PWHT CS) 01P-P-007
CL21 (PWHT CS) 01P-P-008
CL21 (PWHT CS) 01P-P-009
CL21 (PWHT CS) 01P-P-010
CL21 (PWHT CS) 01P-P-011
CL21 (PWHT CS) 01P-P-012
CL21 (PWHT CS) 01P-P-013
CL21 (PWHT CS) 01P-P-014
CL21 (PWHT CS) 01P-P-015
CL21 (PWHT CS) 01P-P-016
CL21 (PWHT CS) 01P-P-017
CL21 (SS) 01P-P-001
Attachment-4

Location Guidance of thickness measurement for Static Equipment

4 Points Nozzle
E-1 E-5 Horizontal View
12 or N
45°

See P-4
9 or W 3 or E

6 or S

E-6
E-2 12 o’clock or North
12 or N
A

10:30 or NW 1:30 or NE
9 or W 3 or E

A Sec A-A
6 or S

7:30 or SW 4:30 or SE

E-7 Nozzle
Nozzle size is equal & larger than 12”
12 or N
E-3 Shell
12 o’clock A
12 or N
or north 9 or W 3 or E
3 or E Nozzle size is less than 12”
9 or W
6 or S

A 6 or S
Sec A-A

E-8 Nozzle
E-4 Shell Nozzle size is equal & larger than 12”

12 o’clock 10:30 1:30


A 10:30 or NW
or north 1:30 or NE or NW or NE

Nozzle size is less than 12”


7:30 4:30
or SW or SE
A 7:30 or SW 4:30 or SE

Sec A-A

(1/2)
Location Guidance of thickness measurement for Piping

P-1 Straight Piping


12 or N
12 o’clock A
or north

9 3
or W or E

A
6 or S
Sec A-A

P-2 Straight Piping


A 10:30 1:30 or NE
12 o’clock or NW
or north

7:30 or SW 4:30 or SE
A
Sec A-A

P-3 Cap
A 12 or N
12 o’clock
or north

More than 25mm 9 3 or E


from weld side or W
A
6 or S
Sec A-A

P-4 Elbow North North


12
(or East) (or East)
North
(or East) 12 o’clock
45° 45°
9 12 o’clock 9 o’clock
12 o’clock
9 o’clock 6 o’clock 9 3
3 o’clock
6 o’clock 45°

6
Horizontal Vertical Vertical

P-5 Reducer 12 or N

12 o’clock A
or north 9 3
or W or E

A 6 or S
Sec A-A

(2/2)

You might also like