0% found this document useful (0 votes)
804 views10 pages

Case - 1: Foundation & Pedestal Design Document

The document provides design calculations for pipe supports with different pipe diameters. It includes 4 cases with pipe diameters of 50 inches, 32 inches, 24 inches, and 12 inches. For each case, it specifies the pipe diameter, loading, support arrangement, foundation size, and pedestal size. The document then shows sample calculations for the 12-inch case for parameters like foundation thickness, reinforcement requirements, bearing capacity, bending check, and shear check. The calculations are to check that the foundation and pedestal can adequately support the pipe based on the given loadings and design code requirements.

Uploaded by

Jayanti Raha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
804 views10 pages

Case - 1: Foundation & Pedestal Design Document

The document provides design calculations for pipe supports with different pipe diameters. It includes 4 cases with pipe diameters of 50 inches, 32 inches, 24 inches, and 12 inches. For each case, it specifies the pipe diameter, loading, support arrangement, foundation size, and pedestal size. The document then shows sample calculations for the 12-inch case for parameters like foundation thickness, reinforcement requirements, bearing capacity, bending check, and shear check. The calculations are to check that the foundation and pedestal can adequately support the pipe based on the given loadings and design code requirements.

Uploaded by

Jayanti Raha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 10

OWNER PMC DESIGN CALCULATION FOR PIPE SUPPORT

FOUNDATION & PEDESTAL DESIGN


DOCUMENT

DOC. No. :EPCC02-BRCL-C00-CVL-DOC-EQFD-


FW03
Revision No. 0
ISSUED : 16.08.2019 PAGE of

CASE -1 PIPE DIA 50 INCH 1277 MM


PIPE DIA = 50 INCH
LOADING = 14 TONNE
HEIGHT OF SUPPORT = 2.1 M

SUPPORTING ARRANGEMET - SADDLE SUPPORT


FOUNDATION - 2 LEG R.C.C
PEDESTAL - 600 MM x 600 MM
SPACING BETWEEN SUPPORT - 2M

CONSIDERING MAX LOADING ,


PLACE THE PIPE AT MID POINT OF SUPPORT -
MAX B.M = [ 14 x 1 x 1 / 2 ] = 7 TM
CONSIDERING MAX MOMENT REQUIRED MODULUS OFSECTION =
( 7 x 100000 / 1650 ] = 424.24242 CM3
USING ISMB 350 Zx = 778.9 CM3
s bc = 898.7 KG/SQCM
MAX LOADING = 7 TONNE
PEDESTAL - 2600 MM x 600 MM
FOUNDATION - 3200 MM x 1200 MM

CASE- 2 PIPE DIA 32 INCH 817.28 MM


CASE -1
LOADING - 8 TONNE
SUPPORTING ARRANGEMET - SADDLE SUPPORT
FOUNDATION - 1 LEG R.C.C
PEDESTAL - 1200 MM x 400 MM
FOUNDATION - 1700 MM x 1200 MM
SPACING BETWEEN SUPPORT - 0M

CASE- 3 PIPE DIA 24 INCH 612.96 MM


CASE -1
LOADING - 6 TONNE
SUPPORTING ARRANGEMET - SADDLE SUPPORT
FOUNDATION - 1 LEG R.C.C
PEDESTAL - 1200 MM x 400 MM
FOUNDATION - 1500 MM x 1200 MM
SPACING BETWEEN SUPPORT - 0M
OWNER PMC DESIGN CALCULATION FOR PIPE SUPPORT

FOUNDATION & PEDESTAL DESIGN


DOCUMENT

DOC. No. :EPCC02-BRCL-C00-CVL-DOC-EQFD-


FW03
Revision No. 0
ISSUED : 16.08.2019 PAGE of

CASE- 4 PIPE DIA 12 INCH 306.48 MM


CASE -1
TOP OF PIPE = 0.35 M ABOVE G.L
LOADING - 3 TONNE
SUPPORTING ARRANGEMET - SADDLE SUPPORT
FOUNDATION - 1 LEG R.C.C
PEDESTAL - 500 MM x 400 MM
FOUNDATION - 1000 MM x 900 MM
SPACING BETWEEN SUPPORT - 0M
OWNER PMC DESIGN CALCULATION FOR PIPE SUPPORT

FOUNDATION & PEDESTAL DESIGN


DOCUMENT

DOC. No. :EPCC02-BRCL-C00-CVL-DOC-EQFD-


FW03
Revision No. 0
ISSUED : 16.08.2019 PAGE of

PARAMETERS - 12 INCH PIPE DIA


TYPE - SADDLE SUPPORT
Construction Material Grade Description - SAMPLE CALCULATION
Grade of Concrete = M 25
Grade of Steel = fy 500 N/mm2

Pipe Support - Support Marked


Depth of Foundation below G.L = 1.5 m

Design Parameters -
Clear Cover to Steel = 50 mm
Density of Concrete = 2.5 T/Cum
Unit Weight of Soil Mass = 1.8 T/Cum
Permissible Bearing Capacity at Founding Depth = 10 T/Sqm
Density of Structural Steel = 7.85 T/Cum

Foundation Design Calculation -

Safe Bearing Capacity of Foundation = 10 T/Sqm Net


Depth of Foundation below G.l = 1.5 m
Vertical Load on Foundation = 3.00 T (Max)
Considering eccentricity of loading = 0.08 M ASSUME Mx
Vertical Load on Foundation = 3.00 T (Min)
Uplift Loading = 0T
Moment on Foundation (Mx ) = 0.23 Tm
Moment on Foundation (My ) = 0.00 Tm (Mz as per Staad Output Result)
Assume Foundation Size = 1( L ) m x 0.9 m (B )

Assume Foundation Thickness = 0.3 m


Effective depth of Foundation = {( 300 ) - 50 - 6 } = 244 mm

Pedestal Dimension = 0.5 ( a ) m x 0.4 ( b ) M


NUMBER OF PEDESTAL 1 NOS C/C SPACING - 0M
Area of Foundation ( A ) = { 1 x 0.9 } = 0.9 Sqm

Zx of Foundation = { (1/6) x 1 x 1 x 0.9 } = 0.135 m3


Zy of Foundation = { (1/6) x 0.9 x 1 x 1 } = 0.15 m3

BEARING CAPACITY CHECK -


Stress due to Vertical Load on Foundation ( P/A ) = ( 3 / 0.9 ) = 3.33 T/Sqm

Stress due to Moment Load on Foundation ( Mx/Zy ) = ( 0.225 / 0.15 ) = 1.5 T/Sqm

Stress due to Moment Load on Foundation ( My/Zx ) = ( 0 / 0.135 ) = 0 T/Sqm

Pmax = (P/A) + ( Mx / Zy ) + ( My / Zx ) = [ 3.33 + ( 1.5 ) + ( 0 ) ] =


4.83 T/Sqm Less than Safe B.C - Safe
Pmin = (P/A) - ( Mx / Zy ) - ( My / Zx ) = [ 3.33 - ( 1.5 ) - ( 0 )] =
1.83 T/Sqm Less than Safe B.C - Safe
Gross Loading on Foundation = Foundation Self Weight + Weight of Soil Surcharge over Foundation

Foundation Self Weight = ( 1 x 0.9 x 0.3 x 2.5 ) = 0.68 T


Pedestal Self Weight = { 0.5 x 0.4 x ( 0.4 + 1 - 0.3 )} x 2.5 = 0.55 T
Weight of Soil Surcharge over Foundation = [{ (1 x 0.9)- ( 0.5 x 0.4)} x ( 1.5 + 0.4 - 0.3 ) x 1.8 ] =
2.016 T
Additional Load on Foundation due to Self Weight and Surcharge load = ( 0.68 + 2.016 + 0.55 ) =
3.246 T
Additional Pressure on Foundation due to Self Weight and Surcharge load = { 3.246 / ( 1 x 0.9 ) } =
3.61 T/Sqm
Hence, Minimum Pressure on Foundation = ( 1.83 + 3.61 ) = 5.44 T/Sqm
Safe - No Uplift
Hence, Maximum Pressure on Foundation = ( 4.83 + 3.61 ) = 8.44 T/Sqm

CHECK FOR BENDING -


Max Lever Arm ( Distance between foundation edge to column edge ) = ( 1 - 2.6 ) / 2 =
-0.8 M along Y axis
Max Lever Arm ( Distance between foundation edge to column edge ) = ( 0.9 - 0.4 ) / 2 =
0.25 M along X axis
Max Lever Arm among the above Two combinations to be considered as Lever Arm =
0.25 M
Max Moment for Bending of Foundation Slab = { 8.44 x (0.25 x 0.25 / 2 )} =
0.26 Tm / m width of Foundation slab
Mu/bd = {1.5 x 0.26 x 10000000 } / { 1000 x 244 x 244} =
2
0.066 N/mm2

pt = 0.12 % (% of Steel required) (Table -2 /SP-16)


3.6 Sqcm

Using 10 dia HYSD bar Spacing required = 100/{( 3.6 / 0.785) -1 }=


28 cm C/C
Provide 10 dia HYSD bar @ 150 mm C/C
Provided Steel = 6.28 Sqcm Provided Steel is more than required Steel - Safe
% Steel Provided = 0.26 %

CHECK FOR SHEAR -


ONE WAY SHEAR -
Foundation Size = 1(L)mx 0.9 m (B )
Column Size = 0.5 ( a ) m x 0.4 ( b ) M
Distance from Edge of Foundation = 0.006 m Longer Direction of Fdn Slab
0.01 m Shorter Direction of Fdn Slab
ARM FOR SHEAR = 0.01 M AFFECTED BY SHEAR
MAX SHEAR FORCE /M = ( 0.01 x 1 x 0 ) = 0 T/M
SHEAR AREA =
( 1 x 0.244 ) = 0.244 SQM/M

SHEAR STRESS = {( 0 x 10000 ) / ( 0.244 x 1000 x 1000 )} = 0 N/MM2


Su = ( 1.5 x 0 ) = 0 N/SQMM
% STEEL = 0.26 %
PERMISSIBLE SHEAR STRESS FOR % OF STEEL = 0.26 % IS 0.36 N/MM2
PERM SHEAR STRESS >ACTUAL SHEAR STRESS - SAFE

PUNCHING SHEAR -
Column Size 0.5 ( a ) m x 0.4 ( b ) M KEEPING INDIVIDUAL FOUNDATION.
Footing Size 1(L)mx 0.9 m (B )

Max Overhang - Longer Side = 0.25 m


Max Overhang - Shorter Side = 0.25 m
Footing Effevtive Depth = 244 mm = 0.244 m

PUNCHING SHEAR FORCE = [ ( 1 x 0.9 ) - 2 x {( 0.5 + 0.244 ) x ( 0.4 + 0.244 )} ] x 0

4 0.65 8.575 5.57 Pipe Loading =


5 0.65 6.575 4.27
6 0.65 4.575 2.97
7 0.65 2.575 1.67 Lever Arm =
Disturbing Moment = 38.34 TM
Resisting Moment =
F.O.S against Overturning = ( 43.22 / 28.813 ) = 1.5 Safe

SUMMARY -
Size of Foundation = 1 M x 0.9 M

Column Reinforcement -
Column Size = 0.5 M x 0.4 M
Height = ( 1.5 + 0.4 - 0.3 ) = 1.1 m
Height / LLD = ( 1.1 / 0.4 ) = 2.75 Acts as Column

p= 0.15 %
Ast = ( 50 x 40 x 0.15 / 100 ) = 3 Cm2
Provide 12 T Reinforcement 4 nos
PROVIDED STEEL IS MORE THAN REQUIRED - HENCE SAFE
(Ref - Soil Test Report - Pg-22)

5.7
0.2 1.1 0.55
0.7 1.6 1.8 2.016

Chk 0.68 0.55 2.016

2.6

0.35 0.35 0.082 0.12

0.785 4.5859873

6.6666667 7.6666667 8 6.28 Spec = 142.85714

1 0.5 0.006
0.9 0.4 0.006

The foundation is not affected by One Way Shear Stress.


0.9
0.5 0.958272

0.9 1.11 -0.21 0 0


0.9 1.11 8.44 -1.7724

25

1.1309734 3 Nos 1