U1a - 735834

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

M2753 FORM U-1A MANUFACTURER'S DATA REPORT FOR PRESSURE VESSELS

(Alternative Form for Single Chamber, Completely Shop or Field Fabricated Vessels Only)
Production Order No.

As Required by the Provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VIII, Division 1 Page 1 of 2
FLT00032
Model

1. Manufactured and certified by Morganton Pressure Vessels L.L.C., 1 Alfredo Baglioni Drive, Marion, North Carolina, 28752
(Name and address of Manufacturer)
2. Manufactured for Zeks Compressed Air Solutions, 1302 Goshen Parkway, West Chester, Pennsylvania, 19380
(Name and address of Purchaser)
3. Location of Installation NOT KNOWN
(Name and address)

Vertical M786892 K8808.1C FLT00032 r 5 735834 2018


(Horizontal or vertical, tank) (Manufacturer's serial number) (CRN) (Drawing number) (National Board number) (Year built)
4. Type

5. ASME Code, Section VIII, Division 1 2017/ N/A N/A N/A


[Edition and Addenda, if applicable (date)] (Code Case numbers) [Special service per UG-120(d)]

6. Shell: SA-414 Gr. G 0.154 in 0 in 16.000" (OD) 2' 8.560"


(Material spec. number, grade) (Nominal thickness) (Corr. allow.) (Inner diameter) [Length (overall)]
Body Flanges on Shells
Bolting
Flange How
No. Type ID OD Min Hub Thk Material Location Bolting Washer (OD, ID, Washer
Thk Attached Num & Size
Material thk) Material
1 Slip on 16.16" 23.50" 1.38 .920 SA-105 Welded Top 16 1-8 - 4 1/2 SA-193 B7 N/A N/A
7. Seams: UW-12 Tp. 1 N/A 70 N/A N/A UW-12 Tp. 2 N/A 65 1
[Long. (welded, dbl., sngl., lap, butt)] [R.T.(spot or full)] (Eff.,%) (H.T. temp) (Time, hr) [Girth. (welded, dbl., sngl., lap, butt)] [R.T. (spot or full)] (Eff., %) (No. of courses)
8. Heads: (a) Material (b) Material
SA-414 Gr. G
(Spec. no., grade) (Spec. no., grade)
SA-414 Gr. G

Location (Top, Bottom, Minimum Corrosion Crown Radius Knuckle Radius Elliptical Ratio Conical Apex Hemispherical Flat Side to Pressure (Convex or
Ends) Thickness Allowance Angle Radius Diameter Concave)
(a) Top 1.380 0 N/A N/A 1.00:1 N/A N/A 23.500 Flat
(b) Bottom 0.176 0 N/A N/A 2.00:1 N/A N/A N/A Concave

Body Flanges on Heads

Min Hub
Type ID OD Flange Thk Material How Attached
Bolting

Thk
Location Num & Size Bolting Material
Washer (OD,
Washer Material
ID, thk)
(a) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
9. MAWP 165 psi N/A at max. temp. 450 °F N/A
(Internal) (External) (Internal) (External)
Min. design metal temp. -20 °F at 165 psi . Hydro, pneu., or comb. test pressure HYDRO. at 215 psi .

Proof test N/A .

10. Nozzles, inspection and safety valve openings:


Purpose (Inlet, Outlet, Diameter or Material Nozzle Thickness Reinforcement Attachment Details Location (Insp.
No. Type
Drain, etc.) Size Nozzle Flange Nom. Corr. Material Nozzle Flange Open.)
Inlet / Outlet 2 1/4"NPT Coupling SA-181 Cl. 70 N/A 0.479 N/A Welded N/A Shell
Inlet / Outlet 1 1/2 "NPT Coupling SA-181 Cl. 70 N/A 0.428 N/A Welded N/A Head
Inlet / Outlet 2 6" Pipe SA-106 Gr. B SA-105 0.280 N/A Welded welded Shell

11. Supports: Skirt No Lugs 1 Legs N/A Other N/A Attached Welded to Head
(Yes or no) (Number) (Number) (Describe) (Where and how)
12. Remarks: Manufacturer's Partial Data Reports properly identified and signed by Commissioned Inspectors, have been furnished for the following items of the report:
N/A
(Name of part, item number, Manufacturer's name and identifying stamp)
Anti-vibration system and safety valve not supplied. It is the responsibility of the user.
Joggle in heads UW 13.1 (i)
Threaded couplings.
Impact test exemption per UCS-66 and UG-20 (f).
Corrosion allowance not required per UG-25(d) (non-corrosive service).
Constructed under the provisions of UG-90(c)(2). Tested in the vertical position.
FORM U-1A Page 2 of 2

Manufactured by Morganton Pressure Vessels L.L.C., 1 Alfredo Baglioni Drive, Marion, North Carolina, 28752
Manufacturer's Serial No. M786892 CRN K8808.1C National Board No. 735834

CERTIFICATE OF SHOP/FIELD COMPLIANCE


We certify that the statements made in this report are correct and that all details of design, material, construction, and workmanship of this vessel
conform to the ASME BOILER AND PRESSURE VESSEL CODE, Section VIII, Division 1. "U" Certificate of Authorization Number 38776
expires July 17, 2021 .
Date 06/01/2018 Co. name Morganton Pressure Vessels L.L.C. Signed
(Manufacturer) (Representative)
CERTIFICATE OF SHOP/FIELD INSPECTION

Vessel constructed by Morganton Pressure Vessels L.L.C. at 1 Alfredo Baglioni Drive, Marion, North Carolina, 28752
I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and employed by
The Hartford Steam Boiler Inspection and Insurance Company, of Hartford, CT
have inspected the component described in this Manufacturer's Data Report on November 15, 2018 ,
and state that, to the best of my knowledge and belief, the Manufacturer has constructed this pressure vessel in accordance with ASME BOILER
AND PRESSURE VESSEL CODE, Section VIII, Division 1. By signing this certificate neither the Inspector nor his/her employer makes any
warranty, expressed or implied, concerning the pressure vessel described in this Manufacturer's Data Report. Furthermore, neither the Inspector
nor his/her employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.

Date 11/15/2018 Signed Commissions 14136, NC1596


(Authorized Inspector) (National Board Authorized Inspector Commission number)

3210766 exe: v6.3.35 Form and version: U1A-19