RZ Series Technical Bulletin: Subject: CF Card

This technical bulletin provides information about using CF cards with RZ2/RZ3 models: 1) Riso recommends using their branded CF32M card to ensure compatibility. 2) Generic CF cards up to 128MB may work but are not guaranteed. 3) When downloading firmware updates, the program file must be placed in the root directory of the CF card and cannot be in subfolders. It will only download if the version is different from what is currently on the machine.

Uploaded by

Kendrew Blades
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
136 views2 pages

RZ Series Technical Bulletin: Subject: CF Card

This technical bulletin provides information about using CF cards with RZ2/RZ3 models: 1) Riso recommends using their branded CF32M card to ensure compatibility. 2) Generic CF cards up to 128MB may work but are not guaranteed. 3) When downloading firmware updates, the program file must be placed in the root directory of the CF card and cannot be in subfolders. It will only download if the version is different from what is currently on the machine.

Uploaded by

Kendrew Blades
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Page 1/2

RZ series TECHNICAL BULLETIN


ISSUE NO. RZT-006
MODEL: RZ 2/3 Series DATE : 12-Nov.-04

Data Category Field Modification Trouble Shooting General Information Safety Advice

Our Ref.:
SUBJECT: CF Card
The descriptions below are to explain how CF card works on RZ2/ RZ3 models basically.

1) Riso recommended CF card

Part No. : 023-75058-009 CF32M; SU


This part is a unit parts which is consist of DMC-32 & DM PC card adopter.
This is the one which is used on RP3 for document storage.
This part is registered as spare parts, not as product.
This is what Riso can ensure that CF card will work on RZ model properly.

2) Performance check of CF card (Generic CF card)


Overseas technical had asked to collect CF card which are sold in local market in some
countries. They had been checked by our side and the most of them worked on RZ properly.
(The test result has been already informed back to you.) But Riso cannot ensure those cards
always work properly. If you doubt the application of the card, please use DMC-32 which we
recommend to use on RZ.
2)-a Capacity limit for CF card
Up to 128 MB
If the card is over 128MB, it would not be able to be
recognized on RZ.

3) Program download ( RZ firmware download)


3)-a Place the program file on the first directory on CF card F drive
drive.
OLNMV137.dl1
Do not change the file name and extension when you
copy the program file to CF card. 3)-a where to place program file
3)-b If the program is placed in 2nd directory on CF card,
program download will not start.
3)-c Version priority 1 F drive
If the program version is same version as the machine
has already, the download won't start. Folder 1
3)-d Version priority 2 OLNMV137.dl1
If the program version is different from the one on
machine already, download will start. 3)-b Program download won't run in
This will start even if the version is lower than the one this case.
on the machine.
3)-e 2 or more program for same model
If there are 2 or more program file for the machine is RZ machine
F drive
placed on the first directory on CF card, It can not be V3.00
controlled which program will start to download. Do not
place 2 or more program file on the same directory. OLNMV200.dl1
3)-f Model different
If program file for the machine is not right, the 3)-d version is different from the
machine, Program download will start.
download won't start.
3)-g Mixed program for some models
If there are some program files for several models, the
right program model for the machine will be picked up.

Issued By Overseas Technical Sec., Riso Kagaku Corp.


Page 2/2

RZ series TECHNICAL BULLETIN


ISSUE NO. RZT-006

4) REv record
4)-a When REv data is saving, "REV_DATA" directory will be automatically created on CF
card drive.
4)-b If there is communication error between CF card and RZ, "P97" error will appear on RZ.
(P97-939 to 946) Please refer technical manual description.
4)-c If you are saving REv data only, please delete the RZ program files on the first directory
on CF card. If there is RZ program file on first directory on the card (program version is
different from the machine version), program download will start immediately when
power sw is on. You won't be able to go into Test Mode.