VOL 2

REHAB
THE GUIDE

EXTERIOR WALLS
PATH (Partnership for Advancing Technology in Housing) is a new private/public effort to develop, demon­
strate, and gain widespread market acceptance for the “Next Generation” of American housing. Through
the use of new or innovative technologies the goal of PATH is to improve the quality, durability, environ­
mental efficiency, and affordability of tomorrow’s homes.
Initiated  at  the  request  of  the  White  House,  PATH  is  managed  and  supported  by  the  Department  of
Housing and Urban Development (HUD). In addition, all Federal Agencies that engage in housing research
and technology development are PATH Partners, including the Departments of Energy and Commerce, as
well  as  the  Environmental  Protection  Agency  (EPA)  and  the  Federal  Emergency  Management  Agency
(FEMA). State and local governments and other participants from the public sector are also partners in
PATH. Product manufacturers, home builders, insurance companies, and lenders represent private indus­
try in the PATH partnership. 
To learn more about PATH, please contact:

PATH

Suite B 133

451 Seventh Street SW.

Washington, DC 20410

202-708-4250 (fax)

e-mail: [email protected]

website: www.pathnet.org

DISCLAIMER
The statements and conclusions contained in this report are those of Steven Winter Associates, Inc. and
do not necessarily reflect the views of the Department of Housing and Urban Development. Steven Winter
Associates, Inc. has made every effort to verify the accuracy and appropriateness of the report’s content.
However, no guarantee of the accuracy or completeness of the information or acceptability for compliance
with any industry standard or mandatory requirement of any code, law, or regulation is either offered or
implied. The products listed in the report are included only as examples of some available products. No
endorsement, recommendation, or evaluation of these products or their use is given or implied.
E X T E R I O R   WA L L S
VOLUME  2  OF  THE  REHAB  GUIDE

TABLE  OF  CONTENTS

FOREWORD 3

1. INTRODUCTION 4
2. DESIGN & ENGINEERING 6
3. MASONRY/BRICK VENEER 21
4. SHEATHING 28
5. VAPOR RETARDERS & AIR INFILTRATION BARRIERS 32
6. INSULATION 39
7. VINYL SIDING 45
8. METAL SIDING 49
9. WOOD SHINGLES & SHAKES 52
10. SOLID WOOD SIDING 55
11. HARDBOARD SIDING 60
12. ENGINEERED WOOD SIDING 63
13. PLYWOOD PANEL SIDING 65
14. FIBER-CEMENT SIDING 68
15. EIFS & STUCCO 72
16. EXTERIOR TRIM 77
17. SEALANTS & CAULKS 80
18. PAINT & OTHER FINISHES 84

APPENDIX: PROFESSIONAL ASSOCIATIONS & RESEARCH CENTERS 89

Prepared for:
U.S. Department of Housing
and Urban Development
Office of Policy Development
and Research

Prepared by:
Steven Winter Associates, Inc.
Building Systems Consultants
Norwalk, CT

Contract DUIOOCOOOOO5956
August 1999
CREDITS
STEVEN WINTER ASSOCIATES, INC. STAFF MEMBERS
WHO WERE INSTRUMENTAL IN THE DEVELOPMENT AND
PRODUCTION OF THIS GUIDEBOOK INCLUDE:

Steven Winter
Principal-in-charge
Alexander Grinnell
Project manager and principal researcher
Michael J. Crosbie, Ph.D., RA
Editor-in-chief
Christoph Weigel and Masaki Furkawa
Illustrators
Gordon Tully, William Zoeller
Project team members

U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT
OFFICE OF POLICY DEVELOPMENT AND RESEARCH, AFFORDABLE
HOUSING RESEARCH AND TECHNOLOGY DIVISION

David Engel
Director
Nelson Carbonell
Senior architect

GUIDEBOOK DESIGN

Andrew P. Kner
Art Director
Michele L. Trombley
Assistant Art Director
Elizabeth Rosen
Symbols
FOREWORD

President Clinton recognizes that research and technological innovation are crucial if America is to meet
its affordable housing needs. In 1998, the President introduced a major new initiative: The Partnership for
Advancing Technology in Housing (PATH). This initiative brings together leaders from the home building,
product manufacturing, insurance, and financial industries, as well as representatives from federal agen­
cies, to spur housing design and construction innovations.
Thanks to the development of new machinery and materials and the creation of new technologies
and techniques, the construction industry has made great progress. But a breakthrough material, a labor-
saving tool, or a cost-cutting technique is only valuable if it is widely adopted, which means the construction
industry must first become aware of these new developments. 
The Department of Housing and Urban Development can help. We have commissioned a set of
guidebooks that will present state-of-the-art techniques, materials, and technologies for housing rehabil­
itation. This volume, Exterior Walls, is the second of nine guidebooks—known collectively as The Rehab
Guide—that will appear over the next few years. 
We are presenting these guidebooks because, like research and technological innovation, housing
rehabilitation is an essential component of America’s commitment to provide affordable housing. I am
pleased to present this important publication in the hope that it will become a valuable resource that leads
to affordable, high quality rehabilitation, and thus to better housing for all Americans. 

Andrew Cuomo, Secretary

U.S. Department of Housing and Urban Development

1 THE REHAB GUIDE:
E X T E R I O R   WA L L S
INTRODUCTION
This publication, The Rehab Guide: Exterior Walls is one in a series of guidebooks produced by the
U.S. Department of Housing and Urban Development (HUD) to keep the design and construction indus­
try abreast of innovations and state-of-the-art materials and practices in home rehabilitation. As is too
often the case, innovative techniques, materials, technologies, and products are slow to make their way
into  accepted  practice. The  Rehab  Guide series  is  intended  to  accelerate  this  process  by  informing
builders, architects, engineers, and other housing rehabilitation professionals about such innovations and
state-of-the-art practices.
The Rehab Guide was also prompted by the lack of a comprehensive publication to make the
design and construction industry aware of innovative and cost-saving developments in housing rehabilita­
tion. Professional trade magazines, conferences, and trade shows offer some distribution of this informa­
tion, but they are rarely focused on housing rehabilitation, as this series is, nor are they comprehensive.
It is evident that such innovations will not advance unless the industry is made aware of them and they are
tested. 

FOCUS  OF  THE  REHAB  GUIDE


The  focus  of  this  series  is  on  housing  rehabilitation,  which  is  different  than  home  improvement.
Rehabilitate means “to restore to good condition,” not necessarily to improve to a state that is significantly
different than the original. This is a fine line, but it distinguishes this series from “home improvement”
books written for the amateur. The Rehab Guide focuses on building technology, materials, components,
and techniques rather than “projects” such as adding a new room, converting a garage into a den, or
finishing an attic. Nor is The Rehab Guide intended to be a “diagnostic” tool; a number of such books are
already available to the industry.
The  content  for  this  guidebook,  Exterior  Walls,  has  been  gathered  from  professionals  in  the
housing rehabilitation field; manufacturers and suppliers of innovative technologies, materials, compo­
nents, tools, and equipment; trade shows, conferences, reports, and publications considering such issues;
trade organizations; and building research centers.

A  NOTE  ON  SOURCES


Particularly useful sources of technical information on exterior wall design and construction are publica­
tions by APA--The Engineered Wood Association, the Cedar Shake and Shingle Bureau, the Brick Industries
Association, the Western Wood Products Association, the California Redwood Association and other indus­
try associations. Other valuable and detailed sources of information from the general construction indus­
try include technical trade magazines such as Construction Specifier and RSI Roofing Siding Insulation
magazine.  Publications  relating  more  directly  to  residential  construction  include  the  Journal  of  Light
Construction,  Old  House  Journal,  This  Old  House,  Fine  Homebuilding,  Energy  Design  Update,
4
Environmental Building News, Preservation Briefs, and publications of the Forest Products Laboratory
of the U.S. Department of Agriculture. A valuable source of publications on wall construction is the Canada
Mortgage and Housing Corporation, which has an extensive catalog of excellent books and articles on a
wide range of subjects on housing construction and rehab. The most complete and comprehensive books
on exterior wall construction materials are the product information and installation manuals of individual
manufacturers. Other valuable resources are the Troubleshooting Guide to Residential Construction,
produced by the Journal of Light Construction, and Rehabilitation of Wood-Frame Homes, produced
by the U. S. Department of Agriculture.

HOW  THE  GUIDE  IS  ORGANIZED


Nine volumes will eventually make up The Rehab Guide in its entirety, and they are listed on the back cover
of this volume.  Each one is devoted to distinct elements of the house, and within each volume is a range
of issues that are common to that element of home rehabilitation work. The present volume on Exterior
Walls covers the major wall enclosure systems including framing and sheathing; protective strategies such
as building paper, flashing, and housewraps; energy and air infiltration issues; various cladding materials;
and trim. Each volume addresses a wide range techniques, materials, and tools, and recommendations
based on regional differences around the country. Throughout The Rehab Guide, special attention is given
to issues related to energy efficiency, accessible design, and sustainability. 

EASILY  ACCESSIBLE  FORMAT


The Rehab Guide is written and presented in a format intended for easy use. The spiral bound volumes
open flat so that they can be easily photocopied, and they can be assembled and stored in a single three-
ring binder. Within each volume, drawings, photos, and other graphic materials supplement written descrip­
tions of a broad range of items: state-of-the-art and innovative building technology, products, materials,
components, construction and management techniques, tools, equipment, software—virtually any and all
items that make housing rehabilitation more efficient in terms of cost and time. While the content focuses
on present technologies, techniques, and materials that are currently part of the house-building industry,
The  Rehab  Guide also  includes  information  on  materials,  products,  and  procedures  from  other  con­
struction sectors (such as commercial, industrial, institutional) that are relevant to housing rehabilitation.
The information is organized in different sections according to rehab subjects, and under head­
ings that make this book easy to understand. “Essential Knowledge” gives the reader a basic overview of
the important issues related to the section heading. Next, “Techniques, Materials, Tools” presents state-of-
the-art and innovative approaches to accomplishing the work. Each entry is explained in detail, including
its advantages and disadvantages. This makes it easy for readers to compare approaches and choose the
one that is most applicable to their particular project. By design, the “Techniques, Materials, Tools” sec­
tion  is  an  overview,  not  a  detailed  description  of  implementation.  “Further  Reading”  lists  the  valuable
resources relevant to the subject which readers can go to for more detailed information. Finally, “Product
Information” provides names and addresses of manufacturers of products, materials, systems, and com­
ponents mentioned in the text so that more information can be attained. By virtue of their being listed here,
such products are not necessarily being recommended; their existence and availability is being brought to
the reader’s attention. New products should be carefully evaluated in the field as to their efficacy. The prod­
uct lists are not comprehensive, and we encourage readers to bring new materials and products to our
attention to be included in later editions of The Rehab Guide.

5
2 D E S I G N   &
ENGINEERING
2.1 EXTERIOR WALL OVERVIEW
From the time of the first European settlers in North America, the predominant wall framing system for
houses was timber (with wood exterior cladding). Also popular, but to a lesser degree than wood fram­
ing, was masonry construction (most commonly brick or stone). Other exterior wall systems less widely
used included log construction and adobe.
In the first half of the 19th Century, the introduction of machine-sawn lumber and factory-made
nails led to lighter structural systems (Fig. 1), including braced-frame construction, (which combines tim­
ber  framing  and  infill  studs),  and  balloon  framing,  which  replaced  heavy  timber  columns  and  girts
(beams) with light-weight framing members that ran continuously from the foundation to the roof. By the
beginning of World War II, balloon framing had largely been replaced with platform framing, which uses
shorter framing pieces and gains lateral stability from the floor platform. This system prevails today in both
stick-built and prefabricated housing. 

FIGURE 1 BRACED FRAMING BALLOON FRAMING PLATFORM FRAMING 

Because it has been the dominant framing material, the rehabilitation of wood-frame systems will
be given the most attention in this guide. Masonry systems such as stone, brick, and concrete block will
be addressed briefly. Additional recommendations for remedial work will be addressed in the individual
chapters  that  discuss  specific  wall  materials  and  application  systems.  Steel  framing  has  not  been  used
extensively in residential rehab, except occasionally for interior non-load-bearing partitions. Structural

insulated panels (SIPs) have also not been used much in residential rehab work, because it is rare that
large sections of walls are completely replaced.
Older, pre-code-complying domestic structures employed carpenters’ rules of thumb and build­
ings were, for the most part, strong, resilient, and adequate for normal conditions. When buildings fail
structurally,  which  is  infrequent,  it  is  typically  due  to  one  or  more  of  the  following  causes:  inadequate
design, earthquakes, storms and high winds, fire, insect damage, and structural deterioration caused by
moisture. This chapter will outline some of the causes of structural failure, and recommended remedial
approaches and reference sources to be contacted for additional recommendations.

FURTHER  READING
“The Structure of Wood Frame Homes,” Gordon Bock, Old-House Journal, March/April 1992.

2.2 WOOD FRAME SEISMIC
RESISTANCE
ESSENTIAL  KNOWLEDGE
A house’s load-bearing walls and columns transmit live and dead loads from the roof to the foundation,
which in turn distributes these loads to the ground. Resistance is also needed to lateral forces from wind
and seismic occurrences, which can cause racking and displace buildings from their foundations. These
loads are taken into account in the design of newer code-complying buildings, but for houses constructed
before state and local code enforcement it is likely that they were not specifically addressed. For instance,
the use of anchor bolts was not uniformly enforced until the late-1950s, and seismic requirements were
not developed and enforced until the early-1960s.
The  most  serious  structural  damage  to  wood-frame  houses  in  seismic  areas  results  from
insufficient anchoring of the frame to the foundation, and the collapse of “cripple walls” in crawlspaces.
Local municipalities, working on their own and with code agencies, have developed prescriptive standards
that are accepted by local building departments and insurance providers. Typical standards, such as those
approved by the city of San Leandro, California, are described below. Other municipalities may reference
the Uniform Code for Building Conservation (UCBC), 1994 edition, or 1997 for seismic requirements.
Codes are evolving, may vary among municipalities, and should be researched carefully.

TECHNIQUES,  MATERIALS,  TOOLS


1. ATTACH A SILL TO THE FOUNDATION WITH ANCHOR BOLTS. 
Unreinforced brick and block foundations are problematic because anchor bolts are difficult to drill and
install properly, and the mortar may not be strong enough to hold the wall together in an earthquake.
Crumbling, cracked, or porous concrete cannot hold mechanical anchors and will tend to shear adjacent
to epoxied anchor bolts (inadequate or substandard foundations should be rebuilt or replaced to current
code standards). Reinforced concrete foundations are preferable, but they are not typical in older homes.
If the foundation is adequate and there is sufficient height in the crawlspace to use an impact/rotary drill,
the easiest method of attachment of a sill is by means of an expansion bolt or an anchor bolt epoxied into
the foundation (Fig. 2). Sills should be bolted at a maximum of 6 foot intervals with bolts located within
12 inches of each joint or step in the sill, but not less than 9 inches from the end of a sill board. In addi­
tion to, or in lieu of, conventional anchor bolts, special hold-down brackets are often installed at shear
walls or at wall openings. These hold-downs secure the studs/post through the bottom plate into the foun-

7
dations (Fig. 3). Specific reinforcement requirements will depend on individual site and building code

requirements and should be reviewed with a structural engineer.

ADVANTAGES: Simplest, most positive connection.

DISADVANTAGES: May not be possible where there is insufficient headroom to drill.

2. ATTACH A SILL, JOIST, OR STUD TO THE FOUNDATION WITH SIDE BRACKETS
OR STRAPS.
Where it is not possible to install anchor bolts because of insufficient headroom, a variety of fasteners has

been specially developed to affix frames to foundations. Anchors are available from manufacturers such

as Simpson Strong-Tie Co., Inc., among others. Typical products include straps and plates designed for

attachment of plates and joists to the face of foundations and mud sills (Fig. 4).

ADVANTAGES: Can connect walls to foundations in areas with limited headroom.

DISADVANTAGES: Not as strong or direct a connection as anchor bolts.

FIGURE 2 EPOXIED ANCHOR BOLT, EXPANSION ANCHOR BOLT

FIGURE 3 TYPICAL HOLD-DOWNS

FIGURE 4 TYPICAL ANCHORS

3. REINFORCE CRIPPLE WALLS WITH PLYWOOD OR OSB.

The lateral forces of an earthquake are concentrated on the interface of the foundation and the wood

frame. Cripple walls are inherently weak connections and have to be reinforced to prevent buckling and

collapse. This is easily accomplished with plywood or oriented strand board (OSB) structural sheathing

used as a rigid diaphragm connecting the top and bottom plates with the studs (Fig 5). The selection of

the proper fastener type and spacing is critical. For crawlspaces that are not accessible, most municipal­

ities have standards for the application of plywood or alternative structural sheathing to the outside of the

crawlspace. Consultation with a licensed engineer is recommended.

ADVANTAGES: An inexpensive and effective remedy.

DISADVANTAGES:  Requires  accessible  crawlspace,  otherwise  existing  siding  and  sheathing  have  to  be

removed and new sheathing applied to the building exterior.

FIGURE 5 PLYWOOD REINFORCEMENT

4. PROVIDE SECURE LOAD PATH FROM ROOF TO FOUNDATION.

Engineers recommend that a continuous “load path” or “hold down path” be created with metal connec­

tors or sheathing so the walls, floors, and roof act together as a structural unit. This is accomplished by

providing, in addition to the wall/foundation connection, a secure load path between the walls and floors

(in platform construction) and between the walls and the roof. Typical floor-to-floor connectors include

bolted  hold-downs  with  threaded  rods  or  straps  designed  specifically  for  that  use.  The  choice  would

depend on job-site conditions and loading requirements (Fig. 6). Another material used to tie building

components together is plywood or OSB sheathing which provides a hold-down path and resists shear or

racking forces. The lower portion of the plywood sheathing should connect the lower to the upper floor

and be nailed into the bottom plate, the wall studs, the top plate and the second floor rim joist, the upper

portion should connect the rim joists, bottom plate and studs, to the top wall plate (Fig. 7). In areas of

high seismic probability, engineers may specify a top grade of plywood, Structural #1, in lieu of regular

rated sheathing. Consultation with a licensed engineer is recommended. Wall/roof connections in seismic

areas are reviewed in Rehab Guide, Volume 3: Roofs.

ADVANTAGES: Provides structural continuity to the entire house.

DISADVANTAGES: Costly, requires removal of siding and possibly sheathing.

FIGURE 6 FLOOR-TO-FLOOR CONNECTIONS

FIGURE 7 SHEATHING RESISTS SHEAR AND RACKING

FURTHER  READING
A Guide to Strengthening and Repairing Your Home Before the Next Earthquake. Developed by the
Governor’s  Office  of  Emergency  Services,  State  of  California,  and  the  Federal  Emergency  Management
Agency,  revised  May  1995.  Association  of  Bay  Area  Governments  (ABAG)  Publications,  P.O.  Box  2050,
Oakland, CA 94604–2050.
An  Ounce  of  Prevention:  Strengthening  Your  Wood  Frame  House  for  Earthquake  Safety:  A  Do-It-
Yourself Program. Video and book. Governor’s Office of Emergency Services, State of California, 1993.
Association of Bay Area Governments (ABAG) Publications, P.O. Box 2050, Oakland, CA 94604–2050.
“Bracing Walls Against Racking,” Harris Hyman, P.E., Journal of Light Construction, April 1987.

Buildings at Risk: Wind Design Basics for Practicing Architects, Michael J. Crosbie, Washington, DC:
American Institute of Architects, 1998.
How the City of San Leandro Can Help Strengthen Your Home for the Next Big Earthquake in the Bay
Area (publication includes prescriptive details). The City of San Leandro Development Services, Building
Regulation Division, 835 East 14th Street, San Leandro, CA 94577; 510–577–3405.
Prescriptive Seismic Strengthening Plan for Wood Frame Residential Structures, Simpson Strong-Tie Co., 1996.

Rehab Guide, Volume 3: Roofs, Washington, DC: US Department of Housing and Urban Development, 1999.
The San Francisco Bay Area—On Shaky Ground. Association of Bay Area Governments, 1995 (multi-
media  CD-ROM,  1996).  Association  of  Bay  Area  Governments  (ABAG)  Publications,  P.O.  Box  2050,
Oakland, CA 94604–2050.
Structural Strengthening for Seismic Conditions, (Video 1997), Simpson Strong-Tie® Co.
“Tying Down the House,” John Scoggins, Journal of Light Construction, September 1997.

PRODUCT  INFORMATION
Earthquake Resistant Construction Connectors, Simpson Strong-Tie® Co., 4637 Chabot Drive, Suite 200,
Pleasanton, CA 94588; 800–999–5099; www.strongtie.com.
United Steel Products Co. (USP), 703 Rogers Drive, Montgomery, MN 56069; 800–328–5934.

2.3 WOOD FRAME WIND RESISTANCE
ESSENTIAL  KNOWLEDGE
Exterior walls, in combination with interior shear walls that brace them, resist perpendicular and lateral
loads  and  uplift  forces  generated  by  high  winds  (which  can  tear  off  roofs  and  porches).  The  increasing
amount of damage caused by hurricanes to the Gulf and Atlantic coastal states and the mounting costs to
repair and replace existing structures demonstrate the need to better design, build, and retrofit houses for
wind resistance.
While code requirements regarding wind resistance are extensive for new home construction, there
are relatively few requirements for rehab of existing houses (unless the work is extensive enough to warrant
bringing the entire building up to code). Exceptions to this occur in some municipalities, such as Dade County,
Florida, which have specific requirements for rehabing existing buildings. Rehab guidelines regarding wind
11
resistance being considered by local, state, and model code agencies include the following recommendations.
A key aspect of these considerations is whether to provide prescriptive “fixes” for simple building configura­
tions or whether to require that a professional engineer or architect prescribe the specific details. The latter
is recommended for complicated building geometries.

TECHNIQUES,  MATERIALS  ,  TOOLS


1. REINFORCE CONNECTIONS OF WOOD-FRAME WALLS TO FOUNDATIONS.
Depending on the type of foundation and access possible, there are a number of anchor bolts, straps, or
threaded-rod connections that can be used to reinforce the connection of the frame to the foundations.
Many of these connectors are similar to those used in seismic areas. In Northern areas, crawl spaces might
provide accessibility, while foundations in Southern regions are slab on grade or, along the coast, pilings
or piers. Typical rehab options for reinforcement are shown in Figs. 3 and 4.
ADVANTAGES: Relatively simple, cost-effective remedies.
DISADVANTAGES: May involve removing exterior or interior finishes.

2. REINFORCE WOOD-FRAME WALLS FOR SHEAR RESISTANCE.
Winds cause lateral forces on buildings that can, in severe cases, displace and collapse the building walls.
Resistance to these forces is provided by exterior and interior shear walls that brace the building’s struc­
ture and transfer loads to the floors and foundations. The most effective shear walls are made of plywood
or oriented strand board. Alternative systems include other structurally approved sheathings, let-in wood
bracing, metal strapping, “T” bracing, or special stud connectors. For buildings that have qualifying struc­
tural sheathings, a cost-effective retrofit is to increase the number of fasteners or connectors from the
sheathing to the studs or to add resistance with foamed-in-place adhesives such as Foam Seal® products.
This can be accomplished with the removal and replacement of the siding.
ADVANTAGES: A simple way of providing shear resistance.
DISADVANTAGES: Will require removal of siding and may require removal of sheathing if it is not struc­
turally adequate.

3. REINFORCE CONNECTIONS OF WOOD-FRAME WALLS TO FIRST FLOOR. 
Connections  are  simple  to  make  in  new  construction  but  difficult  in  rehab  work  unless  the  siding  is
removed to expose the wall sheathing. Metal straps similar to those used in seismic areas provide struc­
tural continuity from one building component to another (Figs. 5 and 6). 
ADVANTAGES: Provides a continuous load path.
DISADVANTAGES: Requires removal of siding and sheathing, if it is structurally inadequate.

FIGURE 8 WALL/ROOF CONNECTORS

12
4.  REINFORCE CONNECTIONS OF WOOD-FRAME WALLS TO ROOF TRUSSES
AND RAFTERS.
The connection of the exterior walls to the roof structure is the key element in transferring wind loads to

the building frame and in preventing uplift forces from tearing off the roof. While new houses in high wind

areas are required to have metal connectors, older houses most likely do not have them. The simplest con­

nection is made from the outside after the soffit is removed (Fig. 8). This juncture can be reinforced from

the inside, but the top portions of the wall as well as portions of the ceiling at the wall have to be removed

for access. See Rehab Guide, Volume 3: Roofs, for further discussion. 

ADVANTAGES: An effective means of providing uplift resistance.

DISADVANTAGES: Will require removal of soffit material.

5. REINFORCE CONNECTIONS OF WOOD-FRAME WALLS TO ROOF OVERHANGS.

The most vulnerable portion of a building for wind uplift is the connection of roof overhangs and walls.

The typical connection of the wall to the “ladder” overhang (Fig. 9) is inadequate if the overhand exceeds

one foot in depth, and uplift forces can lead to separation of the ladder from the wall. The preferred detail

on new or repaired construction is to use “lookouts” tied to the top of the exterior wall and anchored

back to the adjoining truss or rafter (Fig. 10).

ADVANTAGES: Effective means of providing uplift resistance.

DISADVANTAGES: Will require removal of soffit and modification to gable end.

FIGURE 9 SHALLOW LADDER OVERHAND

FIGURE 10 DEEP OVERHANGS SUPPORTED BY “LOOKOUTS” 13
FURTHER  READING
Buildings at Risk – Wind Design Basics for Practicing Architects, Michael J. Crosbie, Washington, DC:
American Institute of Architects, 1998.

Rehab Guide, Volume 3: Roofs, Washington, DC: US Department of Housing and Urban Development, 1998.

PRODUCT  INFORMATION
High-Wind-Resistant Construction Connectors, Simpson Strong-Tie Co., Inc., 4637 Cabot Drive, Suite
200, Pleasanton, CA 94588; 800–999–5099; www.strongtie.com.
High-Wind Retrofit of Wood Trusses or Rafters to Masonry or Concrete Walls, Simpson Strong-Tie Co.,
Inc., 4637 Cabot Drive, Suite 200, Pleasanton, CA 94588; 800–999–5099; www.strongtie.com.

2.4 REINFORCING EXISTING
MASONRY WALL CONSTRUCTION
ESSENTIAL  KNOWLEDGE
It is often difficult to reinforce existing masonry walls for seismic or high wind resistance. Reinforcement
strategies should be developed for individual buildings on a case-by-case basis by a licensed professional.
Masonry buildings generally perform well in high wind as long as they are reinforced in accordance with
codes,  and  as  long  as  the  connections  to  the  roof  structure  are  adequate  to  prevent  uplift  failure.
Unreinforced masonry buildings perform poorly in seismic areas. The connection to roof structures and
secondary structures such as porches are similar in concept to those used for wood-frame construction
but adapted to masonry. Typical masonry-to-roof connectors are illustrated in Fig. 11.
ADVANTAGES: An effective means of providing uplift resistance.
DISADVANTAGES: Will require removal of soffit material.

FIGURE 11 MASONRY-TO-ROOF CONNECTORS

PRODUCT  INFORMATION
High-Wind Retrofit of Wood Trusses or Rafters to Masonry or Concrete Walls, Simpson Strong-Tie Co.,
14 Inc., 4637 Cabot Drive, Suite 200, Pleasanton, CA 94588; 800–999–5099; www.strongtie.com.
2.5 MOISTURE DETERIORATION
ESSENTIAL  KNOWLEDGE
Water absorbed by structural wood-framing can raise its moisture content, reduce its compressive and tensile
strength, ultimately cause rot and decay, and also attract termites. The most critical points of the building enve­
lope susceptible to leakage are: tears or gaps in the roofing material; at flashings and penetrations of the roof
plane; roof/wall connections; wall penetrations such as windows and doors; rainwater penetration through sid­
ing materials; and wall/foundation connections. Roofing water-related problems are discussed in the Rehab
Guide, Volume 3: Roofs, wall penetration leaks at wall openings are covered in Volume 4: Windows and
Doors, and water penetrations through wall materials are covered in other chapters of this volume.
Wall/foundation junctures are particularly critical because run-off from roofs and walls collects
on the ground at that location. If the sill and floor assembly are not sufficiently elevated, rot will occur.
Older timber-framed and balloon-framed structures with sill plates that rest on a few courses of stone (or,
occasionally, directly on grade) are at greatest risk. Platform-framed houses that have foundation walls
with the sill a minimum of 6 inches to 8 inches above grade (to comply with code minimums) are less sus­
ceptible to rot and decay from moisture. However, unless the grade below the siding is sufficiently sloped
away and kept clear of debris and plantings, moisture can wick up through the siding and cause decay. Rot
and decay cannot progress in the absence of moisture.
Sills can be inspected from inside the building in the crawl space or from outside by removing a
portion of the siding and sheathing. The condition of the wood can be checked with a sharp object such
as a screwdriver or pocket knife. Sound wood will split into fibrous splinters, while decayed wood will sep­
arate into small chunks of a dark brown, black, or gray color. Decay can also be revealed by rapping the
surface of the wood member; a dull, hollow sound frequently indicates decay below the surface.
Decayed sills can be replaced with full-sized members, partially replaced with built-up lumber,
or stabilized with structural epoxy conservation techniques. 

TECHNIQUES,  MATERIALS,  TOOLS


1. REPAIR SILL WITH BUILT-UP LUMBER.
If the sill is a heavy timber section (4 by 6 to 8 by 8) and the wall studs are 3 or 4 inches wide, the house
is most likely of post-and-beam construction. The roof and floor loads are transferred by means of beams
(girts) to the columns and the studs between columns carry very little weight. Accordingly, it is possible to
temporarily support the building at its bearing columns and replace sections of the sill below. If the build­
ing is balloon-framed or platform-framed, with individual studs carrying the load, the wall has to be sup-
ported  along  its  length.  Once  the  load  is  taken  by  the  shoring,  deteriorated  sections  of  the  sill  can  be
removed with a reciprocating saw and a mallet and chisel. Pressure-treated sections of lumber can be
scabbed (spliced) into the affected area (using APA-The Engineered Wood Association (APA) approved
gap-filling adhesives) and fastened with galvanized drywall screws, spikes, or other rust-resistant fasteners.
ADVANTAGES: Relatively simple fix for sills requiring isolated repairs.
DISADVANTAGES: Requires accurate assessment of sill condition; sections of rotting sill may be overlooked.

2. REPLACE LARGE SECTIONS OR THE ENTIRE SILL.
If significant decay runs the length of the sill, it should be replaced in its entirety. The exterior wall can be
supported  by  jacking  timbers  placed  next  to  the  plate,  running  perpendicular  to  the  joists  (Fig.  12).
Sections of the sill can be cut with a chain saw or reciprocating saw between joists that frame into the sill.
A new sill is placed on top of the foundation. If the floor joists do not rest directly on top of the sill they
can be hung from the new sill with joist hangers or, if the ends of the joists are not decayed, they can be
mortised into the new sill. Replacing a sill is much easier with stud-framed houses, as individual joists rest

15
FIGURE 12 JACKING FLOOR JOISTS

on top of the sill. Because each stud of a load-bearing wall carries a relatively small portion of the load,

the process of supporting the floor joists while removing the rotted sill or rim joist is relatively simple.

Once the new sill is anchored to the foundation, the grade next to the wall should be sloped to provide

drainage away from the wall.

ADVANTAGES: Replacing a major portion or the entire sill is a way to comprehensively address the prob­

lems of decay, and may be more cost-effective than a series of small, interim repairs.

DISADVANTAGES: Costly; might require extensive exterior sheathing and siding repairs.

3.  REPAIR  PORTIONS  OF  THE  FOUNDATION  OR  SUPPORTING  COLUMNS


USING EPOXY TECHNIQUES.
Small portions of the foundation or columns that support structure above can be reconstituted and con­

solidated using liquid epoxy or epoxy putty (Fig. 13). This is particularly appropriate if the building is of

historic significance.

ADVANTAGES: Can repair existing structure without removal.

DISADVANTAGES: Time consuming. Not practical with large areas of work.

FIGURE 13 EPOXY REPLACEMENT

16

FURTHER  READING
Renovating Old Houses, George Nash, Newtown, CT: Taunton Press, 1996.
Renovation: A Complete Guide (Second Edition), Michael W. Lichfield, New York: Prentice Hall, 1991.
The Old House Journal Guide to Restoration, edited by Patricia Poore, New York: Dutton, 1992.
Rehabilitation of Wood-Frame Homes, USDA, Forest Service, Handbook No. 704, February 1998.
“Saving House Sills,” “Structural Repair Under Old Floors,” Old House Journal, March/April 1992.
“The Structure of Wood-Frame Houses,” Old House Journal, March/April 1992.

PRODUCT  INFORMATION
IN-SITU STRUCTURAL REPAIRS
Preservation Resource Group, P.O. Box 1768, Rockville, MD 20849–1768; 301–309–2222.
Abatron,  Inc.  Wood  Restoration  Systems,  5501–95th  Avenue,  Department  HP,  Kenosha,  WI  53144;
800–445–1754; www.abatron.com.

2.6 MITIGATING INSECT DAMAGE
ESSENTIAL  KNOWLEDGE
Destructive insects include termites, carpenter ants, and wood-boring beetles (Fig.14). Termites access
above-ground wood through cracks in foundation walls or slabs or build tubes from the ground up to the
wood above to provide the necessary moist environment. Having infested the wood, they can live there
indefinitely with no ground contact if the moisture level is adequate. Sources of moisture include roof
leaks, condensation, or plumbing problems. Termites in crawlspaces may build free-hanging tubes from
wood members to the ground. Evidence of termite infestation includes: the presence of mud tubes; dam-
aged wood; active swarms of winged termites or large numbers of discarded wings or evidence of con­
ducive conditions (e.g., moisture; wood-to-ground contact; inadequate ventilation; settlement cracks; and
other likely entry points). Detection tools include: visual inspection; probing of the wood surface with a
screwdriver or pocket knife; sounding (tapping) of the affected area with a hard object such as the handle
of  the  screwdriver;  the  use  of  a  moisture  meter  to  detect  likely  environments;  infestations;  listening
devices; electronic gas (methane) detectors; and fiber optic devices to inspect areas otherwise inaccessible
to visual inspections. Many species of termites prefer wood that has been previously invaded by fungi. To
guard against drying, termites consume wood only until the outer shell remains, leaving the wood look­
ing intact. Wood that has been tunneled by termites will sound hollow when tapped with a solid object.
Termites will attack all types of wood including redwood, cypress, and junipers if the wood has aged and
the chemicals that provide termite-resistance (alcohols, oils, gums and resins) have leached out. Termites
have been known to penetrate and damage many non-cellulosic materials such as drywall, plaster, stucco,
and plastics. Items damaged include some softer metals (e.g., lead, copper, aluminum). Insulation board
used as a substrate for Exterior Insulation and Finish Systems (EIFS) has often been riddled by termites lead­
ing to the prohibition of foam plastic within 8" of the ground in states with very heavy infestation of termites.
Ants are the most reported pests in many parts of the country and range from the arctic to the
tropics. Carpenter ants, the major group that damages buildings, tunnel through wood but do not con­
sume it for food. Main colonies of carpenter ants, given their name because they typically dwell in and

17
FIGURE 14 TERMITE POWDERPOST BEETLE CARPENTER ANT

excavate  wood,  are  located  in  trees  surrounding  the  infested  structures.  Inside  buildings,  satellite
colonies will nest in a variety of voids including walls, hollow doors, behind appliances, in floor cavities
and attic rafter spaces, under kitchen cabinets, bathroom fixtures, etc. Carpenter ant infestations can be
located by their very presence or by piles of “frass,” pieces of dead ants and other insects mixed in with
bits of wood.
There is a variety of wood-boring beetles. Among the best known and most destructive are the
powderpost, roundhead, and flathead beetles. Some beetles attack both hardwood and softwoods, usually
limiting their feeding to the sapwood portion. Their presence is usually indicated by frass and a number
of exit holes in wood, although the number of holes does not necessarily indicate the activity or severity
of infestation. The potential for damage is greatest when the infestations are new and the number of exit
holes is low. Beetles are typically introduced into structures in building materials that have been infested
at lumber yard stock piles, although they may also enter homes in finished wood products such as floor­
ing, paneling, furniture, and firewood. Dead tree limbs may serve as a habitat from which flying adults may
enter the house. 

TECHNIQUES,  MATERIALS,  TOOLS


MITIGATE AND CONTROL INSECTS.
Mitigation methods to reduce the likelihood of termite infestations include: removal of all cellulous mate-
rial on or beneath the soil adjacent to structures or in crawlspaces; eliminating details that allow materi­
als to continue from the exterior wall into the soil; providing adequate clearance between grade and struc­
tural members to allow access and inspection of termite tunnels; eliminating dirt-filled porches, steps, and
similar  raised  attachments;  providing  termite  shields;  and  using  pressure-preservative-treated  lumber.
Treatment strategies include the use of: liquid termiticides; termiticidal foams that fill cracks and gaps in
materials and can be injected into soils; borate insecticides; and termite baits. The variety of treatment
products is widespread and new products are being developed. The effectiveness of individual products,
especially new ones, may vary depending on local soil and building-related conditions. Local pest control
experts should be contacted for site-specific recommendations. Certain treatments may be prohibited by
local authorities.
Mitigation methods for subterranean termites are of little benefit against drywood termites since
infestations originate from “swarmers” entering through vents, cracks, or other openings. Drywood ter­
mites live within the affected wood. Their presence is indicated by piles of fecal pellets or discarded wings
adjacent to holes or joints in the affected wood. Methods to control drywood termites include the use of:
pressure-preservative-treated wood; sprayed insecticides; silica aerogel dust (a desiccant); borate dust;
fumigation; heat treatment; and “drill-and-treat” with termiticides. Some new, and as yet unproven, strate-
18
gies include the use of microwave equipment and electrocution. Local pest control experts should be con­
tacted for site-specific recommendations. Ant mitigation methods include: reducing moisture conditions;
sealing cracks in the building’s exterior; trimming trees away from the house roofs; keeping log piles away
from houses; and eliminating wood-to-soil contact. Treatment strategies include a variety of sprayed insec­
ticides, baits, and soil treatment. Treatment of affected houses for wood-boring beetles includes: remov­
ing infested wood; use of sprayed insecticides; fumigation; moisture reduction; and use of borate sprays.
ADVANTAGES: Soil treatment and elimination of cellulose in backfill can be effective deterrents.
DISADVANTAGES:  New  chemical  treatments  need  replenishing  sooner  and  are  less  effective  than  those
approved in the past. Treatments can be costly.

FURTHER  READING
Handbook of Pest Control, Eighth Edition, Arnold Mallis, Mallis Handbook & Technical Training Company, 1997.
The  Approved  Reference  Procedures  for  Subterranean  Termite  Control,  National  Pest  Control
Associations (NPCA), 1991.

2.7 FIRE DAMAGE TO WOOD FRAMING
ESSENTIAL  KNOWLEDGE
Damage from fire can range from the total loss of a building and its contents to minor inconvenience from
smoke odors. The process of determining the restoration requirements of a fire-damaged building varies
considerably with the building location and extent of damage. Insurance adjusters often make settlement
offers based on their own evaluation of restoration needs, although they may employ consultants on more
complex projects. Recommendations may also originate from local fire marshals, building department
officials, contractors, consulting engineers, industrial hygienists, public adjusters, and architects hired by
the building owner. Unless the damage is limited, the restoration process can be complicated, involving
structural, electrical, HVAC, and plumbing systems, as well as building finishes. In addition, significant
health and comfort issues arise from the residual smoke, combustion gases, moisture from fire depart­
ment  hoses,  and  the  existence  of  products  containing  asbestos.  For  these  reasons  the  selection  of  a
restoration contractor who is experienced and knowledgeable in current techniques is critical. At least
one national association, the Association of Specialists in Cleaning and Restoration (ASCR) manages train­
ing and certification programs and publishes a restoration guideline.

TECHNIQUES,  MATERIALS,  TOOLS


FIRE-DAMAGE RESTORATION.
The first step in a restoration project is to assess the damage to the wall structure. In 2 by 4 construction,
significantly  charred  members  are  generally  removed  in  their  entirety.  Heavy  timber  construction  can
remain  (according  to  the  American  Society  of  Civil  Engineers),  once  the  char  is  removed  and  if  the
remaining section is still structurally adequate (after a reduction-in-size-factor of  1/4 inch on all sides).
Char is removed by scraping and abrasive blasting. It should generally be removed because it holds odors,
although encapsulating coatings inhibit their transmittal. New construction, replacing the damaged con­
struction,  should  meet  codes  for  new  construction.  Smoke-damaged  materials  should  be  cleaned  and
deodorized as necessary. The use of ozone generators, sometimes used to remove odors and contami­
nants, is controversial and considered by a number of specialists to be ineffective and potentially danger­
ous (see Further Reading). 

19
ADVANTAGES: Restoration can be relatively effective in removing odors when fire damage is slight.
DISADVANTAGES: Restoration after serious fires is expensive and complicated. Finding competent restora­
tion professions is sometimes difficult.

FURTHER  READING
Evaluation, Maintenance, and Upgrading of Wood Structures, American Society of Civil Engineers.
“Research  Sheds  New,  Unfavorable  Light  on  Ozone  Generators,”  IEQ  Strategies,  P.O.  Box  129,  Center
Strafford, NH 03815–0129; 603–664–6942; www.cutter.com/energy/.
NIDR - Guidelines for Fire and Smoke Damage Repair, National Institute for Disaster Restoration (a
division  of  the  Association  of  Specialists  in  Cleaning  and  Restoration);  1997;  410–729–9900;
www.ascr.org.
Odor Removal Manual, Volume I, Clifford B. Zlotnik, Unsmoke Systems, Inc.
Restoration Technology, Volume I, Clifford B. Zlotnik, Unsmoke Systems, Inc.

PRODUCT  INFORMATION 
Unsmoke Systems, Inc., 1135 Braddock Avenue, Braddock, PA 15104; 800–332–6037.

20
3 MASONRY/
BRICK VENEER
Brick and stone masonry are among the oldest, long-lasting, and most versatile materials. Throughout the
U.S. many brick homes, centuries old, continue to perform well. In many regions brick is the predomi­
nant  building  material  because  of  its  low  maintenance,  non-combustibility,  availability,  moisture  resis­
tance, and aesthetic appeal.
Any corrective work should be preceded by a careful visual assessment of the wall’s conditions
to determine overall patterns of deterioration and distress so that underlying problems can be appraised
and corrected. Some common problems include foundation displacement (see Rehab Guide, Volume 1:
Foundations); water penetration into the wall assembly; inappropriate material choices; poor construc­
tion practices; stresses caused by expansion and contraction due to temperature changes; shrinkage of the
wood structural walls; and routine aging of the masonry facing and joints.
This chapter focuses on repair and rehabilitation of brick masonry, primarily clay and concrete
brick veneer wall construction, as this is the most common construction type, although many of the rec­
ommendations apply also to stone, concrete block, and solid brick construction. Topics include cleaning,
protective coatings, repointing, and repair.

3.1 CLEAN EXISTING MASONRY WALLS
ESSENTIAL  KNOWLEDGE
The  decision  to  clean  a  masonry  veneer  facade  requires  careful  consideration  because  the  cleaning
process may remove weathered material as well as accumulated dirt. It might be justified if the dirt and
pollutants (such as that from acidic rain, efflorescence, bird droppings, deteriorated paint, etc.) are hav­
ing a harmful effect on the wall, however, “lightening up” the facade for cosmetic reasons may not be pru­
dent. The benefits of cleaning should be weighed against the possibility of adverse affects on the masonry
surfaces and mortar joints, as well as on flashing, windows, and other elements. 
The  least  invasive  cleaning  is  usually  recommended;  improper  or  over-cleaning  can  cause
irreparable damage. Cleaning strategies for historic buildings should be reviewed with a restoration pro­
fessional. All cleaning procedures and materials should be tested prior to the start of the project. For large
jobs, the test area should be a minimum of 20 square feet. Before chemical cleaners are used, the wall
should be saturated with water to avoid staining by heavy concentrations of cleaning agents. A waiting
period of at least one week after finishing the test area is recommended in order to judge the results of
the cleaning procedure, especially if chemical agents are used. For recommendations on cleaning specific
stains see Further Reading.

TECHNIQUES,  MATERIALS,  TOOLS


1. CLEAN WITH BRUSH BY HAND.
This technique employs a variety of cleaning agents including water, detergents, proprietary cleaners, and
21
acid. Efflorescence can often be removed by dry brushing, with pressurized water, or with proprietary
cleaners. Dirt can be removed with water or with a detergent solution such as trisodium phosphate and
laundry detergents dissolved in water. Many stains can be removed with conventional “kitchen cleaners.”
Other stains, resulting from leaching of salts or coloring agents within the brick, require acid cleaners,
which should be used very carefully in diluted form. Some acids, such as hydrochloric (muriatic acid)
can seriously degrade mortar. Acid can also discolor lighter masonry surfaces and damage metal, glass,
marble, terra cotta, limestone, and cast stone surfaces, and can also leave a white film that is difficult to
remove. Walls treated with acid must be thoroughly flushed with water after cleaning.
ADVANTAGES:  Easiest  and  most  conservative  approach.  Employs  the  widest  variety  of  cleaning  options.
Allows for most cost-effective approach. Can confirm the appropriateness of cleaning strategies prior to
large-scale application.
DISADVANTAGES: Appropriate only for relatively small areas. Time consuming; requires direct access to
wall surfaces. 

2. CLEAN WITH PRESSURIZED WATER.
Useful in covering large areas, pressurized cleaning may be accomplished with low- or moderate-pressure
water, steam, or water in combination with detergents or other cleaning solutions. Walls should be satu­
rated with water prior to cleaning and completely flushed after cleaning. Care should be taken with acidic
compounds as discussed above. 
ADVANTAGES: Cost-effective for large areas; can reach heights of 100 feet. 
DISADVANTAGES:  Requires  specialized  equipment.  Nozzle  pressures  in  excess  of  700  psi  may  damage
brick, especially sand-finished material, and erode mortar joints. May not remove certain stains as effec­
tively as brush cleaning by hand. Disposal of water run-off may be a problem. Excess water can bring sol­
uble salts from within the masonry to the surface. Cannot be used during periods of freezing weather.
Steam  cleaning  with  or  without  chemicals  may  be  useful  in  removing  paint  and  embedded  grime,  but
requires careful analysis, testing, and experienced professionals. Can be costly.

3. CLEAN BY ABRASIVE-BLASTING.
Abrasive-blasting, usually with sand, is often considered a means of last resort, and in many cases is pro­
hibited because it can erode ornamental details and destroy or scar brick and stone faces. Less abrasive
and softer aggregates than sand, such as glass and plastic beads, and organic matter such as finely ground
nut shells, wheat starch, peach and apricot pits, and cherrystones, are sometimes used on small sections
of decorative brick, stone or metal elements. 
ADVANTAGES: Will clean when other techniques will not.
DISADVANTAGES: Potentially destructive; use only after careful analysis and testing. May be prohibited.

FURTHER  READING
“The Cleaning and Waterproof Coating of Masonry Buildings,” Preservation Briefs, No. 1, Robert C. Mark,
National Park Service, Washington, D.C., 1975.
“Cleaning Brick Masonry,” Brick Industries Association Technical Note #20, Rev. 11, November 1990.
“Gentle Blasting—New Methods of Abrasive Cleaning,” Valerie Sivinski, Old House Journal, July/Aug. 1996.
“Moisture Resistance of Brick Masonry,” BIA Technical Note #7F, January 1987.

22
3.2 APPLY COLORLESS PROTECTIVE
COATINGS
ESSENTIAL  KNOWLEDGE
Colorless coatings are sometimes considered for masonry walls in order to enhance water resistance or
to repel graffiti. The chemicals used fall within two classifications: films and penetrates. These two have
significantly different physical properties and performance. Whereas these coatings may have some lim­
ited usefulness, in many cases they provide little or no advantages, require frequent replacement, and can
have adverse effects. Brick manufacturers should be contacted for recommendations on the use of color-
less coatings.

TECHNIQUES,  MATERIALS,  TOOLS


1. APPLY FILM COATING TO MASONRY WALL.
Products include acrylics, stearates, mineral gum waxes, urethane, and silicone resins. The large molec­
ular size of these materials prevents them from penetrating into the masonry.
ADVANTAGES: Can reduce the absorption of some bricks and can bridge hairline cracks. Can keep sur­
faces clean and help prevent graffiti from penetration into the masonry surface.
DISADVANTAGES: Can inhibit evaporation of water within the masonry through the exterior face, which can
cause the coating to cloud or spall under some freeze/thaw conditions. Generally not recommended in
such environments. Sheen or gloss may darken material. Vulnerable to cracking due to thermal fluctua­
tions. Urethane often breaks down under Ultraviolet light. Silicones do not chemically bond with substrate,
and as a result have a short life.

2. APPLY PENETRATING COATING TO MASONRY WALL.
These coatings typically penetrate into the masonry to depths up to 3/8 inch, due to their small molecular
structure. Materials include silane and siloxanes that chemically bond with silica- or aluminum-content
materials to make them water repellent. These coatings are not generally necessary on new walls or brick
veneer walls with drainage cavities. 
ADVANTAGES: Coatings can last up to 10 years, decrease absorption, and increase water repellence. Unlike
film coatings, penetrating coatings allow wall to breathe. Siloxanes have been shown to be effective on
some multi-wythe brick barrier walls where water penetration is a problem.
DISADVANTAGES: May have limited lifetime; cannot be applied over film coatings. May react with other
building materials. Can kill vegetation and emit harmful vapors. Will not seal cracks in mortar joints. 

FURTHER  READING
“Colorless Coatings for Brick Masonry,” BIA Technical Note #6A April 1995.

23
3.3 REPOINT EXISTING WALLS
ESSENTIAL  KNOWLEDGE
While the service life of many types of brick can exceed 100 years, the longevity of mortar joints, depend­
ing on the exposure, is closer to 25 years, according to the Brick Industries Association (BIA). At some
point the mortar joint will fail, allowing water to enter the wall cavity. Conditions that require repointing
may include: mortar erosion more than 1/4 inch, crumbling mortar, and hairline cracks in the mortar and
between the mortar and brick.

TECHNIQUES,  MATERIALS,  TOOLS


REPOINT EXISTING WALL.
Visual observation in combination with a light scraping with a metal tool can detect most deficiencies.
Other conditions requiring repairs beyond repointing are discussed in section 3.4. Where repointing work
is undertaken on houses of special architectural or historical significance, advice should be sought from
a preservation specialist. Portland cement mortar was not used before the beginning of the 20th century.
To avoid serious brick damage the compressive strength of the repointing mortar should be similar to or
weaker than that of the original mortar. If it is not, dead loads and stresses from the expansion and con-
traction of the brick can transfer loads through the new mortar into the brick and can spall and crack the
brick face. Mortars used in more recent construction include types N and O (Table 1).

TABLE 1 MORTAR TYPES AND INGREDIENTS BY VOLUME

Type Cement Hydrated Lime Sand


N 1 1 6
O 1 2 9
K 1 4 15

ADVANTAGES: Repointing walls can stabilize deterioration, strengthen walls, and provide weathertightness.
DISADVANTAGES: Costly, may require scaffolding. Requires skilled and thorough mechanics.

FURTHER  READING
“Mortars for Brick Masonry,” BIA Technical Note #8, revised Aug. 1995.
“Repointing (Tuckpointing) Brick Masonry,” BIA Engineering and Research Document #622.

3.4 REPAIR EXISTING MASONRY WALLS
ESSENTIAL  KNOWLEDGE
There are certain conditions where repointing alone is not effective and replacement of a portion of a wall
may be required. Some of these include: 

■ Wall cracking associated with thermal movement: Such cracks are cyclical and will open and close with
thermal swings. These cracks may gradually expand as dislodged mortar accumulates in the crack after
24
each cycle. The cracks should be cleaned and protected with flexible sealants. Remortaring cyclical cracks
will prevent them from closing and may lead to further cracking. In some instances, the masonry may need
to be cut and expansion joints installed. 

■ Wall cracking associated with moisture penetration and caused by freeze/thaw cycles and corrosion:
Examples include cracking around sills, cornices, eaves, parapets, joints between dissimilar materials,
and other elements subject to water penetration and freezing; cracking around clogged or non-function­
ing weep holes at lintels and at the base of brick veneer cavity walls. A number of companies, including
Mortar  Net™  and  Heckman  Building  Products,  Inc.,  make  plastic  mesh  products  for  cavity  wall  con­
struction that suspend mortar droppings above the weep holes, thereby reducing the chance of blocking
them with mortar debris (Fig. 1). Mortar Net™ also makes a vertical insert between bricks that acts as a
continuous weep (Fig. 2).

FIGURE 1 NO. 365 TRASH MORTAR DIVERTER CAVITY DRAINAGE SYSTEM

FIGURE 2 WEEP VENT

■ Wall cracking associated with failure of structural elements. Above-ground examples include cracking
or displacement of brick over openings resulting from deflection or failure of lintels or the deterioration
of mortar joints in masonry arches; cracking from outward displacement of sloped roofs due to lack or
failure of collar ties; bulging and cracking of walls caused by deteriorated or inadequate wall ties; crack­
ing due to inadequately supported point loads; cracking due to ground tremors, nearby construction, or
heavy traffic. Light gauge (22 or 24 ga.) corrugated wall ties typically used in residential construction are
not recommended, according to the BIA, for three reasons: the tie shape allows water to flow more freely
to the interior of the wall; they are susceptible to corrosion; they have poor strength to transfer loads
between the brick wythes and the building structure. Adjustable ties, similar to those recommended for
use with metal studs, (Fig. 3) are preferred. Serious structural problems require a professional engineer’s
assistance in determining appropriate corrective measures.

25

FIGURE 3 CONVENTIONAL CORRUGATED TIE  PREFERED WIRE TIES

■ Deteriorated masonry: A number of factors, in addition to structural distress, can contribute to the dete-
rioration of a masonry wall, including weathering effects of rain, UV, temperature changes, as well as the
effects of chemicals in the air or ground, inappropriate cleaning or coatings, and erosion from faulty lead-
ers and down spouts.

TECHNIQUES,  MATERIALS,  TOOLS


REPAIR MASONRY WALL.
If individual bricks or masonry units, or sections of the masonry wall, require replacement, they may be
removed relatively easily by cutting out the units to be replaced and replacing with new material. The arch
action of masonry walls can often prevent adjacent sections from collapsing if the area to be removed is
small. Alternatively, in the event that the masonry ties are missing or deteriorated, a number of companies
make stabilization systems that connect exterior brick wythes with backup walls (Fig. 4). These are either
mechanically-attached pins or ties that are drilled directly through the veneer into its substrate, or ties that
are anchored to the substrate with epoxy cements (see Product Information). Consultation with a profes-
sional engineer is advised if the affected area of wall is significantly large, or if the brick failure is due to
underlying structural problem.
ADVANTAGES: The repair or replacement of brick on low structures is relatively simple and cost-effective.
DISADVANTAGES: Replaced brick and mortar will not match color of existing wall. The replacement of
brick on high walls will require scaffolding and is costly.

PLAN

SECTION
FIGURE 4 STABILIZATION TIES

26
FURTHER  READING
“Anchored Brick Veneer Wood Frame Construction,” BIA Technical Note #28, revised Aug. 1991.
“Brick Masonry Cavity Walls—Detailing,” BIA Technical Note #21B, Jan. 1987.
“Brick Veneer Basics,” Rob Swanson, Journal of Light Construction, June 1994.
“Brick Veneer Existing Construction,” BIA Technical Note #28A, Sept. 1988.
“Getting Started with Brick Veneer,” Steve Thomas, Journal of Light Construction, Nov. 1997.
“Guideline on the Rehabilitation of Walls, Windows, and Roofs,” U.S. Department of Housing and Urban
Development, 1986.
“Guidelines  for  Residential  Building  Systems  Inspection,”  U.S.  Department  of  Housing  and  Urban
Development, 1986. 
Preservation Briefs 1: The Cleaning and Waterproof Coating of Masonry Buildings, Robert C. Mark,
U.S. National Park Service, Nov. 1975.
Preservation Briefs 2: Repoint Mortar Joints in Historic Buildings, Robert C. Mark, Patterson Tiller, and
James S. Askins, U.S. National Park Service, Sept. 1980.

PRODUCT  INFORMATION
DRAINAGE MESH

Mortar Net™ USA Ltd., 3641 Ridge Road, Highland, IN 46322; 800–664–6638; www.mortarnet.com.

BRICK TIES, ACCESSORIES, AND STABILIZATION SYSTEMS

Dur-o-Wal®,  Inc.,  3115  North  Wilke  Road,  Suite  A,  Arlington  Heights,  IL  60004;  800–323–0090;
www.dur-o-wal.com
Heckman Building Products, Inc., 4015 West Carroll Avenue, Chicago, IL 60674; 800–621–4140.
Helifix®, 30 Millwick Drive, Weston, Ontario, Canada M9L 1Y3; 800–561–3026.
Hohman  and  Bainard,  Inc.  30  Rasons  Court,  P.O.  Box  5270,  Hauppauge,  NY  11788–0270;
800–645–0616; www.H-B.com.

27
4 S H E AT H I N G
ESSENTIAL  KNOWLEDGE
Exterior wall sheathing serves a number of functions. It provides rigidity and shear resistance to the main
framing elements; it is part of the barrier system that keeps out the destructive effects of moisture; it pro­
vides varying degrees of insulation; and it can serve as the nail base for exterior siding.
Until the mid-1960s, when plywood was introduced, the dominant sheathing material was 1-by-3 -
inch and 1-by-4-inch wood boards, typically nailed diagonally to the stud frame. Today the most common
wall  sheathing  materials  are  oriented  strand  board  and  plywood,  which  together  account  for  approxi­
mately 55 percent of the sheathing market, with slightly more plywood sold than OSB (other siding prod­
ucts are described below). It is important to recognize that APA - The Engineered Wood Association (APA)
does not differentiate between plywood and oriented strand board (OSB) under its APA Rated Sheathing
program. OSB prices have dropped by half over the past several years, and in some areas of the country
it is about half the price of comparable plywood. OSB is expected to be the most common sheathing mate-
rial by 2002. 
If the finished siding has been well maintained, the wall sheathing should not have deteriorated.
Exceptions to this would be deterioration from moisture trapped behind the finished siding. Moisture entry
is due to improperly flashed or caulked joints between the siding and openings such as doors and windows;
inadequate or poorly fabricated flashing at the wall/roof juncture; water driven by high winds between sid­
ing material during rain storms; moisture penetration through mortar joints in brick veneer walls; and the
lack of, or improperly lapped, moisture retarder such as building paper or housewrap behind the siding.
Much of the research into sheathing failure suggests that, particularly in the case of Exterior Insulation and
Finish Systems (EIFS), it should be assumed that moisture will penetrate the finished siding and that provi­
sions should be made to allow the system to be self-draining between the finish material and the sheathing
by means of furring strips, drainage channels, plastic matting, or other devices.

TECHNIQUES,  MATERIALS,  TOOLS


1. REPAIR EXISTING WALL SHEATHING.
The specific sheathing repair will depend on the location and extent of damage and the type of sheathing
encountered. There is very little possibility of consolidating existing sheathing material. Replacement is
necessary if the material is unsound and can no longer function as intended. Replacement of sheathing
will require removal and replacement of siding as well.
ADVANTAGES: Localized repairs of sheathing are cost-effective if the damage is limited.
DISADVANTAGES: Localized repairs will only mask the problems if they are widespread and result in a
patchwork of new siding. If the problems are widespread the affected sheathing should be replaced in its
entirety and new siding installed.

2. REPLACE EXISTING SHEATHING WITH ORIENTED STRAND BOARD.
Introduced in the early 1980s, OSB (made with rectangular-shaped wood strands cross-oriented in layers
for better structural performance) has replaced particleboard, “flakeboard,” “chipboard,” and “wafer-
board” as the most popular alternative to plywood sheathing. OSB utilizes a variety of fast-growing wood
species,  including  aspen,  southern  yellow  pine,  poplar,  birch,  and  mixed  hardwoods,  with  waterproof
phenolic resin or polyisocyanate binders. Available in varying thicknesses, it typically comes in 4-by-8-foot
sheets, but can also be custom ordered in lengths up to 24 feet and in widths up to 12 feet. 
ADVANTAGES: Excellent shear resistance, dimensional stability, and bond durability under normal conditions.

28
Increasingly popular and readily available nationally. Economical (significantly less expensive than plywood).
Recognized by all three model code agencies. Can serve as a nail base for a variety of siding material.
DISADVANTAGES: Edges can swell if subject to continuous wetting. Has a relatively low R-factor of 1.25/inch. 

3. REPLACE EXISTING SHEATHING WITH PLYWOOD. 

Structural plywood is generally identified in terms of the veneer grades (A-B, B-C, C-D) used on the face

and back of the panels or sheets, or by a term suggesting the panel’s intended use (APA Rated Sheathing).

Veneer  grades  define  appearance  in  terms  of  natural  unrepaired  growth  characteristics  and  allowable

number and size of repairs that may be made during manufacture. According to the APA-Engineered Wood

Association, the minimum face veneer grade permitted in exterior plywood is C. D-grade veneer is used

in panels intended for interior use or in applications protected from the weather. CDX (exterior adhesive)

panels should not be used in applications where the plywood is permanently exposed to weather or mois­

ture. According to APA, the “CDX” plywood is not a recognized grade designation. A better designation is

(DOC) PS1-95 (a prescriptive standard that references plywood only). (DOC) PS2-92 is a performance

standard that allows the supplier to submit either plywood or OSB. Plywood sheathing also comes in a

structural - 1 grade, a higher performing grade than normal sheathing, which is used for shear walls in

seismic areas.

ADVANTAGES: Long considered the highest-performing sheathing. Has excellent structural and weathering

characteristics. Can be used as a nail base for virtually any type of siding, including both cements and syn­

thetic stuccos, and brick veneer applications.

DISADVANTAGES: Considerably more expensive than similar structural sheathing such as OSB, thus losing

market share. Has relatively low R-factor of 1.25/inch.

4. REPLACE EXISTING SHEATHING WITH FIBERBOARD SHEATHING.

Fiberboard sheathing has a 40-year track record in the construction industry, and is in wide use through-

out  the  country.  Known  under  a  variety  of  names,  such  as  “blackboard,”  “grayboard,”  and  “buffalo

board,” the material is made from recycled newspaper, wood fiber, and other cellulose products, held

together with a binder. It is available in regular density, which requires additional corner bracing, and high

density with sufficient racking strength to be used without additional bracing (unless required by local

code officials).

ADVANTAGES: Historically less expensive than most other sheathing material. Has higher R-value (approx.

2.4/inch) than OSB, gypsum sheathing, and paper board sheathing. Is vapor-permeable. Can be used as a

substrate for a variety of finish materials including stucco and wood.

DISADVANTAGES: Has a lower R-value than insulated sheathings. Cannot be used as a nail base for alu­

minum and vinyl clapboard siding (siding must be nailed to studs or furring strips). Becoming less cost-

competitive with OSB in some areas. 

5. REPLACE EXISTING SHEATHING WITH GYPSUM SHEATHING.

In use for many years as a substrate for stucco, brick veneer, and a variety of other siding materials where

fire-rated assemblies are required by code officials. There is a variety of different types of gypsum sheath­

ing available as both nonfire-rated and fire-rated.

5.1. PAPER-FACED GYPSUM SHEATHING. 

In use for over 30 years, combines a wax-treated water resistant gypsum core with a water repellant paper

facing.

ADVANTAGES:  Economical,  widely  available  in  4-by-8-foot  and  2  by  8  feet  sheets  of  varying  thickness.

Relatively  inexpensive  sheathing  for  brick  veneer,  stucco,  and  EIFS.  Provides  fire  ratings  for  a  variety  of

assemblies.

DISADVANTAGES: Standard paper-faced gypsum cannot be left exposed for more than four weeks  before

applications of finish material. There have been problems with delamination of the paper face when used

under exterior insulation finish systems (EIFS). Requires careful handling, as edges are subject to breakage.

29
5.2. GLASS MAT-FACED GYPSUM SHEATHING.

A  product  recently  developed  by  Georgia  Pacific,  Dens-Glass  Gold™  combines  inorganic  glass  mats

embedded with a water resistant and silicone-treated gypsum core and an alkali-resistant surface treat­

ment. The product is more water resistant and generally performs better than paper-faced gypsum sheath­

ing, particularly as a substrate to EIFS and brick veneer. Available in  1/2- and  5/8-inch thicknesses and

lengths of 8 to 10 feet, and greater on special order. 

ADVANTAGES: Resistant to wicking, moisture penetration, and delamination. Can be installed and exposed up

to six months before application of finish siding. Superior performance compared to paper-faced gypsum.

Can be used as a substrate for a wide variety of siding applications, but not as a nail-base. Does not require

additional bracing for normal applications. As light-weight and easy to handle as paper-faced sheathing.

DISADVANTAGES: Costs up to 50 percent more than paper-faced gypsum sheathing. R-value for  1/2-inch

thickness  is  0.56;  5/8-inch  thickness  is  0.67,  which  is  considerably  less  than  for  insulative  sheathing.

Cannot be used as a nail base for siding.

5.3.  GYPSUM  SHEATHING  MADE  WITH  A  NON-PAPER-FACED  BLEND  OF  CEL­


LULOSE FIBER AND GYPSUM.
Developed  recently  as  a  high-performing  alternative  to  paper-faced  boards  by  Louisiana  Pacific,

FiberBond™ fiber-reinforced wall sheathings are made from recycled newsprint, perlite, and gypsum,

with a special water-resistant face treatment. 

ADVANTAGES:  Stronger  and  more  moisture  resistant  than  paper-faced  boards.  Structural  wall  bracing;

superior resistence to screw withdrawal. Can be used as a substrate for EIFS, brick veneer, and a variety

of  other  claddings.  Higher  impact  strength  than  other  gypsum  sheathings;  harder  edges  and  ends.

Available in up to 12-foot lengths. Uses recycled materials.

DISADVANTAGES: Somewhat heavier than other 4 x 8 sheets of gypsum sheathing (paper-faced: 56 pounds,

Dens-Glass:  64  pounds,  FiberBond:  72  pounds).  Priced  comparable  to  Dens-Glass;  significantly  more

expensive than paper-faced. Unfinished exposure limited to 60 days. Cannot be used as a nail base for sidings.

6. REPLACE EXISTING SHEATHING WITH PAPERBOARD SHEATHING.

In use for over 60 years, paperboard sheathing is a code- approved, low-cost alternative to the other struc­

tural sheathings, and has found a considerable following among large home builders for new construc­

tion. Available from Simplex Products Division (Thermo-Ply™) and other manufacturers, in thicknesses

from 0.078 to 0.137 inch, it can be obtained in sheets up to 80 inches wide and 16 feet long, with both

reflective foil surfaces and non-reflective. Vapor-permeable sheathing is under development. It is often

available to builders with their own private label.

ADVANTAGES: Does not require additional shear bracing. Recognized as structural sheathing by national

model codes. Less expensive than other sheathing alternatives. Excellent air infiltration resistance due to

overlapping joints.

DISADVANTAGES: Thinness of the material makes it difficult to use in small-scale rehab projects as infill

for thicker sheathing products. Not as strong as OSB or plywood. Sheathing material has R-value of 0.2, but

is claimed to be greater with reflective surface and air space, but less than other insulating sheathing. May

require adjustments to wood window trim detailing due to thinness of material. Cannot be used as a nail-

base for siding products.

7. REPLACE EXISTING SHEATHING WITH FIBER-CEMENT SHEATHING.

A number of fiber-cement sheathing products are available as structural sheathing underlayments. These

products range from 30-year-old cement and wood fiber products such as Wonderboard, to high-tech

fiber-cement products such as Hardiboard™ and Eternit™, which perform well in high-moisture loca­

tions. As such, they are frequently used as underlayments for thin brick, tile, and EIFS.

ADVANTAGES:  Good  performance  in  high-moisture  locations.  Resistant  to  face  delamination.

Noncombustible, strong, and rigid.

DISADVANTAGES: More costly than gypsum board and other types of sheathing. Not typically used for

siding systems other than for EIFS.
30
8. REPLACE EXISTING SHEATHING WITH FOAM INSULATING SHEATHING.
With increased energy conservation mandated by state and model energy codes, and an increased aware­
ness by the public of possible cost savings and environmental benefits, the use of insulating sheathings
including polyisocyanurate (ISO), extruded polystyrene (XPS), and molded expanded polystyrene (EPS)
has grown steadily. This is especially true with steel construction, which has potentially large heat losses
through thermal bridging. Foam insulating sheathings generally are not structural and require structural
sheathing underlayment, such as OSB, or other approved form of shear bracing; they require a 15-minute
fire-rated barrier (usually gypsum) when used on the interior of habitable residential spaces. Foam insu­
lating sheathings are discussed in Chapter 6, Insulation. See Product Information for a list of suppliers. 
ADVANTAGES: Foam insulating sheathing provides the most energy-saving method of providing insulation
on the outside of walls with R-values up to 7.7/inch for ISO insulation material. Provides a thermal break.
Can also be used in cavity wall construction and as a substrate to stucco and EIFS systems.
DISADVANTAGES: Most foam sheathings are not structural sheathings. Applications of many siding prod­
ucts  over  foam  sheathings  require  special  nailing  provisions  (see  individual  siding  manufacturers’
specifications). Thicknesses of 1 inch and over present attachment problems to existing or new framing
if not adequately addressed.

FURTHER  READING
House Building Basics, APA-Engineered Wood Association, APA Form X461, 1997.
Oriented Strand Board, APA-Engineered Wood Association, APA Form W410, April 1996.
OSB Performance by Design, Structural Board Association, 1997–98.
Residential & Commercial Design/Construction Guide, APA- Engineered Wood Association, APA Form
E30, April 1996.

PRODUCT  INFORMATION
PLYWOOD AND OSB
APA–The  Engineered  Wood  Association,  P.O.  Box  11700,  Tacoma,  WA  98411–0700;  253–565–6600;
www.apawood.org.

OSB
Structural Board Association, 45 Sheppard Avenue East, Suite 412, Willowdale, Ontario, Canada M2N 5W9;
416–730–9090; www.sba-osb.com.

RIGID FOAM INSULATION
Celotex Building Products, P.O. Box 31602, Tampa, FL 33631–3602; 813–873–4230.
Dow Chemical Company, Styrofoam Brand Products, 2020 Willard H. Dow Center, Midland, MI 48674;
800–258–2436.
Owens Corning, One Owens Corning Parkway, Toledo, OH 43659; 800–354–PINK or 800–GET–PINK.
Tenneco Building Products, 2907 Log Cabin Drive, Smyrna, GA 30080; 800–241–4402.

RADIANT BARRIER/PAPER BOARD PRODUCTS
Energy-Brace™ reflective sheathing; Fiber-Lam, Inc., P.O. Box 2002, Doswell, VA 23047; 804–876–3135.
Thermo-ply™  reflective  sheathing;  Simplex  Products  Division,  P.O.  Box  10,  Adrian,  MI  49221;
517–263–8881.
31
5 VA P O R   R E T A R D E R S
& A I R I N F I LT R AT I O N
BARRIERS
5.1 VAPOR RETARDER
ESSENTIAL  KNOWLEDGE
Vapor retarders first appeared in building construction in the 1920s. Early theories held that moisture
vapor will migrate from a region of high concentration towards a region of low concentration along a lin­
ear path. The amount of moisture transfer is dependent on the differences in concentration and the vapor
permeability of the membrane separating the two regions. This is the theory of vapor diffusion, which
viewed the flow of moisture vapor directly analogous to the conductive flow of thermal energy. In this the­
ory, air movement, and the moisture propelled by it, were not considered to be major factors. In the early
1950s, Canadian research found that air movement was the primary mechanism of moisture vapor migra­
tion. Without active air infiltration control, vapor retarder barriers become ineffective.
Current theory on vapor retarders indicates that both air infiltration and direct diffusion play
significant roles in the transfer of moisture vapor and, therefore, both must be accounted for. Effective
vapor retarders must have a water vapor permeability not exceeding 1.0 grains per hour per square foot
per inch of mercury vapor pressure difference (referred to as 1.0 perms), and must be installed in such
a manner as to prevent air leaks at joints and laps.
Although the issue of what makes a vapor retarder effective is generally settled, controversy still
remains  as  to  where  to  install  it,  if  at  all.  From  this  standpoint,  the  authority  on  the  subject  is  the  1997
ASHRAE Handbook of Fundamentals, which has more to say on the topic than any of the model codes. In
what is defined as heating climates (4,000 heating degree days, base 65ºF, or more), vapor retarders belong
on the interior side of the insulation. In warm, humid, cooling climates (Florida and Gulf Coast) where mois­
ture vapor transfer conditions are effectively reversed, vapor retarders are best placed close to the exterior.
In  mixed  climates  (not  fitting  either  of  the  above  definitions),  the  vapor  retarder  should  be
placed to protect against the more serious condensation condition, summer or winter. If in a mixed cli­
mate the winter indoor relative humidity is kept below 35 percent, a vapor retarder at the interior side of
the insulation is usually not required, and an exterior vapor retarder strategy is most effective. Where win­
ter interior humidity is not controlled or if a humidifier is used, an interior vapor retarder is most useful.
Vapor  retarders  should  never  be  placed  on  both  sides  of  a  wall.  Where  a  vapor  retarder  is
employed, the opposite wall surface must provide a permeable surface to allow drying to occur. Thus, in
hot, humid, cooling climates, where a vapor retarder is employed at the exterior, the interior wall surfaces
should be permeable. No vapor retarder paints, kraft-faced insulation, or vinyl wall coverings should be
used. Conversely, in northern heating climates, with interior vapor retarders, the exterior wall coverings
should be vapor permeable.
The primary purpose for installing a vapor retarder in residential rehabilitation is to minimize
32
moisture vapor migration into a wall or roof assemly where it has the potential to deposit condensate when
the dew point is reached. The resulting water in liquid form may cause decay in structural wood framing,
wood-based  sheathing  materials,  and  interior  gypsum  board  or  plaster  wall  coverings.  The  prolonged
presence of moisture will also encourage and facilitate mold and mildew growth, raising potential serious
health concerns for the homes’ occupants.

TECHNIQUES,  MATERIALS,  TOOLS


Vapor retarders can be classified into two major groups: flexible or coatings. Metal foils, laminated foils,
treated paper, and plastic films are flexible sheet goods, while paint, semi-fluid mastic, and hot melt are
coatings. In typical residential construction and rehabilitation, the commonly used materials are exterior-
or interior-applied plastic films, interior-applied foil-faced products, interior treated paper-faced products,
and interior paint coatings.

1. APPLY A VAPOR RETARDER PAINT COATING.
A relatively new product on the market suitable for interior applications is vapor retarder paint. Produced by
several manufacturers, including Sherwin-Williams and Glidden, vapor retarder paints are available as interior
latex primers, typically with a perm rating of approximately 0.7. These primers are formulated to behave much
like standard latex interior primers, in terms of consistency, coverage, and application. They are tintable and
suitable for use over new gypsum board or previously painted surfaces. As with standard interior primers, nor­
mal prep work is needed, and stained areas will require a stain-hiding primer prior to application. The cost
per gallon of the vapor barrier primers is generally competitive with standard interior primers.
ADVANTAGES: Vapor retarder primers are the simplest application in situations where existing wallboard or
plaster surfaces are not to be significantly disturbed. Where interior primers are used, the vapor retarder
function comes at virtually no additional cost. Can effectively upgrade the vapor transmission performance
of an exterior frame wall with no more effort and cost than a new primer and finish coat paint application.
DISADVANTAGES: Appropriate for interior wall surface applications only. With the vapor retarder at the inside
surface of the wall assembly, damage to the paint can compromise retarding ability. If required prepriming prep
work is inadequate, the primer coat vapor retarder effectiveness will be diminished. To be fully effective, all pen­
etrations and material intersections at the interior surface of the wall must be caulked or otherwise sealed.

2. INSTALL TREATED PAPER OR FOIL VAPOR RETARDERS.
For residential rehabilitation purposes, treated paper and foil vapor barriers usually take the form of kraft
and foil-faced batt installation. In a situation where interior wall finish has been removed and new exterior
wall insulation is to be installed, kraft or foil-faced batts are cost-effective and do provide an adequate to mar­
ginal vapor barrier. The amount of unsealed edge is significant and does provide a path for moisture vapor
migration. To improve effectiveness, the kraft or foil flanges can be installed over the face of the studs and
lapped instead of stapled to the inner stud faces (Fig. 1). Convenient and cost-effective, kraft and foil batt
insulation facings do have limitations and their use as a primary vapor barrier should be limited to applica­
tions where vapor barrier performance is not critical, such as in mixed, non-humid climates. In heating cli­
mates with 4,000 degree days or more, a more continuous vapor barrier surface should be considered.
ADVANTAGES:  The  most  cost-effective  interior  vapor  retarder  strategy  where  exterior  wall  framing  is
exposed and new insulation is to be installed. Saves labor costs as fiberglass batt insulation and vapor
retarder are installed in one step.
DISADVANTAGES: Installation requires that walls are stripped to rough framing and that fiberglass batt insula­
tion be installed. The number of joints and edges inherent in this system make for a functionally marginal vapor
retarder,  but  sufficient  for  mixed  climates  or  where  indoor  humidity  is  controlled  in  heating  climates.
Performance can be improved by installing faced batts with flanges attached to narrow face of studs and lapped.

33
FIGURE 1 LAPPED FLANGE

3. INSTALL A CLEAR POLYETHYLENE VAPOR RETARDER.

Most plastic barrier films are either clear polyethylene, black polyethylene, cross-laminated polyethylene, or

reinforced polyethylene. The most basic of these materials, clear polyethylene, is also the most economical.

Available in 4-, 6-, and 10-mil thicknesses, it is best suited for interior wall applications over framing and insu­

lation. As clear poly’s content is up to 80 percent “reprocessed” material, it is also an environmentally sus­

tainable choice. The high recycled content comes at a cost: its quality can be uneven and it generally has poor

tear and puncture resistance. Clear poly should never be used for exterior applications or applications with

more than limited exposure to sunlight. Clear poly is available in widths of 4 to 32 feet in 100-foot long rolls.

As with all polyethylene vapor retarders, for horizontal application over wood framing, staples are most often

used. For maximum effectiveness, joints should be kept to a minimum and seams should be lapped and taped.

ADVANTAGES: Relatively inexpensive and easy to install. In more severe heating climates, the use of inte­

rior polyethylene films is most effective and is practical where interior finish surfaces are removed. Being

transparent, attachments to framing members are simplified, as is the installation of wallboard material

over the polyethylene, because the studs are visible.

DISADVANTAGES: Limited tear and puncture resistance. Clear poly must be installed with care to avoid damage.

All penetrations such as electrical junction boxes must be taped and sealed to ensure effectiveness. Clear poly

can be used only in instances where wall finishes and surfaces have been removed, fully exposing wall framing.

4. INSTALL A BLACK POLYETHYLENE VAPOR RETARDER.

Black polyethylene is nearly identical to clear poly, except for the addition of carbon black to the compo­

sition as a Ultraviolet inhibitor. This permits the use of the polyethylene where some limited exposure to

sunlight is required, such as at exterior wall surfaces. Black polyethylene strength characteristics are sim­

ilar to clear poly, with low tear and puncture resistance.

ADVANTAGES: For exterior wall surface applications in hot, humid, cooling climates, black UV protected

poly films can provide superior vapor retarder performance. 

DISADVANTAGES: Limited tear and puncture resistance. Unreinforced black poly must be installed with care to

avoid damage. Its opaque nature makes installation more difficult by obscuring underlying framing, sheathing,

and other components. Joints and seams must be lapped and taped for full effectiveness. Installation is limited

to conditions where siding has been fully removed and attachment directly to exterior sheathing can be made.

5. INSTALL A CROSS-LAMINATED POLYETHYLENE OR FIBER-REINFORCED
POLYETHYLENE VAPOR BARRIER.
Compared  with  standard  polyethylene,  high-density  cross-laminated  poly  and  fiber-reinforced  poly  are
both specialty products manufactured for applications where higher strength is required. For retrofitting
34
over rough, irregular surfaces, such as solid board sheathing, both products would be less susceptable to
tearing or puncture by lifted nail heads, splinters, or exposed sharp corner edges. Either product would
also be appropriate where rough handling and adverse site conditions are expected.
ADVANTAGES: Stronger than standard poly, reinforced and laminated material can withstand more adverse
site conditions and rough handling. The reinforced and laminated products are typically rated for limited UV
exposure for exterior use and situations where the installation of siding and coverings is delayed. Black rein-
forced and laminated poly can be used as the required weather barrier under exterior siding and cladding.
DISADVANTAGES: Higher initial cost compared to standard black poly. Application is limited to conditions
where siding and exterior wall coverings have been removed. Seams must be lapped and sealed for full
effectiveness.

FURTHER  READING
ASHRAE  Handbook  of  Fundamentals,  Chapters  22–24.  Atlanta:  American  Society  of  Heating,
Refrigeration and Air Conditioning Engineers, 1997.

PRODUCT  INFORMATION
Sto-Cote Products, Inc., 218 South Road, Genoa City, WI 53128; 800–435–2621 (Tu-Tuf products).
Raven Industries, P.O. Box 5107, Sioux Falls, SD 57117–5107; 800–635–3456 (Rufco Moisture/Vapor
Barriers).
Owens Corning, Fiberglass Tower, Toledo, OH 43659; 800–GET–PINK (kraft and foil-faced batt insulation).
Reef Industries, Inc., P.O. Box 750250, Houston, TX 77275–0250; 800–23–6074 (Griffolyn Reinforced
Vapor Barriers).

5.2 AIR INFILTRATION BARRIERS
ESSENTIAL  KNOWLEDGE
Air infiltration barriers, or “housewraps,” as they are known in the industry, have grown in popularity
since their appearance in the 1970s in the wake of the energy crisis. DuPont, one of the first companies
to introduce such a product, came out with Tyvek™ in the late 1970s. Today there is a variety of similar
products that reduce air infiltration and improve energy performance.
The primary attribute of housewraps is their ability to operate as air infiltration barriers while not
forming an impervious vapor barrier. When placed over the exterior surface of the wall sheathing, the mate-
rial allows moisture vapor to escape from the frame wall cavity while reducing convective air movement in
the insulation, thereby helping to maintain the composite R-value of the wall. The greater the exterior air
movement, the greater the benefit.
The ten biggest selling housewrap products fall into one of two basic categories: perforated and non-
perforated. Perforated products are either woven polyethylene, woven polypropylene, spun bonded polypropy­
lene, or laminated polypropylene film. These materials are more impervious to moisture vapor migration than
nonperforated wraps, thus are provided with “micro-perforations” to allow vapor migration and diminish
their vapor retarding properties. With the exception of the polyethylene films, all the perforated housewraps
are further coated with either polyethylene or polypropylene for added air infiltration resistance. In contrast,
nonperforated  housewraps  are  either  spun  bonded  polyethylene  or  fiber-mesh-reinforced  polyolefin.  The
structure of these materials allows water vapor to pass through, while inhibiting air infiltration.

35
In addition to their primary functions as air infiltration barriers and water vapor transmitters,
some (but not all) of the major housewrap brands are code approved as substitutes for required mois­
ture protection barriers. To gain national code approval as a substitute for No. 15 felt, the product man­
ufacturer must apply to each of the three major model building codes, or CABO, and supply specific test­
ing data on water penetration resistance. With code recognition, the product can be used under all siding
applications, including stucco and masonry veneer. Currently, at least four products are listed by all three
model codes as acceptable moisture protection barriers: Amowrap, Pinkwrap, R-Wrap, and Tyvek. Tyvek
also produces a product, StuccoWrap™, that is specifically intended for use with traditional and synthetic
stucco, and is code listed for that application. Other housewraps are acceptable to some codes as weather
resistant barriers. Before using a particular product as a weather barrier, its approval should be verified
with the governing code.
In addition to air leakage resistance, permeance, and moisture resistance, two other material
characteristics are worth considering: UV sunlight resistance, and strength. All major housewrap brands
have a manufacturer’s rated UV exposure time ranging from 120 days to more than 1 year. Some products
are manufactured with antioxidants and UV stabilizers, while others are naturally more resistant by their
composition. In the field, however, covering the housewrap as quickly as practicable is recommended, as
some UV degradation will occur even over a short period, and other unrelated damage to the membrane
can be avoided.
Strength of the housewrap can be critical, as wind conditions or adverse job site handling can
tear or puncture the material during and after installation. Even small holes can negatively affect overall
performance. The inherent strengths of housewrap can be judged on three levels: tensile strength, tear
strength, and burst strength. Respectively, these are the material’s ability to withstand damage from pulling
and  stretching;  withstand  tearing  at  nail  and  staple  locations;  and  to  withstand  separation  of  material
fibers, fabrics, or films. Unfortunately, testing procedures and standards vary between manufacturers, so
product comparison is difficult. Generally, the spun bonded products have good tensile and burst strength
but tear easily; woven and fiber-reinforced have good tear and burst strength, but are susceptible to diag­
onal tensile loading; laminated film products tend to be weakest of all and can lose strength significantly,
making a tight installation more difficult.
Although the wide variety of housewrap products with varying performance characteristics may
appear confusing, they offer a wide selection for any particular job. In northern heating climates, where
interior vapor barriers are the norm, a highly moisture vapor permeable housewrap may be required. In
hot, humid, cooling climates, where an interior vapor barrier is not required, a housewrap with a low air
leakage rate may be preferred. In low-wind environments, a low-strength material may be selected. A par­
ticularly cost-conscious choice would be laminated film.

TECHNIQUES,  MATERIALS,  TOOLS


INSTALL HOUSEWRAP OVER NEW OR EXISTING SHEATHING.
For rehab applications, housewraps will generally be placed over existing solid board sheathing, plywood,
or OSB, or over new plywood or OSB where the existing sheathing needs replacement. Housewraps come in
rolls of varying widths, with 9 feet being the standard. Other widths are available, depending on the manu­
facturer, including 1 foot 6 inches, 3 feet, and 4 feet 6 inches. Roll lengths vary from 60 to 200 feet. Some
custom sizes and lengths are available. Material thickness varies somewhat, but is irrelevant in terms of appli­
cation. Beginning at an outside corner, hold the roll of housewrap vertically and unroll the material across
the face of the sheathing for a short distance. Make sure the roll remains plumb and that the bottom edge of
the housewrap extends over the foundation by two inches. The application should start at an outside corner
extending around the starting point corner by six inches (Fig. 2). 
Manufacturers specify acceptable fasteners, typically large head nails, nails with plastic washers, or
large  crown  staples.  Fastener  edge  and  field  spacing  patterns  are  also  specified.  Housewrap  sheets  are
installed shingle-style, from the bottom up. Horizontal laps should be a minimum of 2 inches; vertical laps
of 6 inches are acceptable (Fig. 3). To be fully effective in their primary role as air infiltration barriers, all
36
FIGURE 2 HEAD LAP

FIGURE 3 SILL LAP

seams and edges must be taped or caulked. While some manufacturers market products for this purpose,
others provide information outlining the performance requirements for approved products.
ADVANTAGES: Relatively low cost, lightweight, easily installed energy conservation and moisture control
product. Especially effective in mixed and northern heating climates where unchecked air infiltration can
significantly  degrade  house  energy  performance  and  occupant  comfort.  Beneficial  in  limiting  airborne
moisture vapor transmission into the wall cavity by limiting air movement, while allowing moisture in the
cavity to be expelled. Some products can be used as a code-approved substitute for building felt.
DISADVANTAGES: Slightly more in initial cost than building felt. Availability of some products may be limited.
Inferior performance as a weather barrier compared with building felt. Nail penetrations in housewrap are
not self-sealing, as they tend to be in felts. Housewraps are not selective vapor permeable membranes: mois-
ture vapor will pass through in both directions. As water-absorptive siding materials such as wood and brick
veneer dry, moisture in vapor form can be forced through housewrap into sheathing and insulation. Less
vapor-permeable building felt can better withstand reverse vapor migration. Some recent studies appear to
indicate that surfactants, a class of substances found in wood, stucco, soap and detergents, can decrease the
natural surface tension of water and allow it to pass through housewraps wetting the underlying materials.
According to anectdotal field observations, this process is most likely to occur in regions with heavy rainfall
and when unprimed wood siding is placed in direct contact with the housewrap.

FURTHER  READING
“Can Moisture Beat Housewrap?”, Ted Cushman, Ed., Journal of Light Construction, June 1997, p. 9.
“Sizing Up Housewraps,” Bruce Greenlaw, Fine Homebuilding, October/November 1994, No. 91, p. 42.

37
“Housewrap  Manufacturers  Prescribe  New  Details  for  Windows  and  Doors,”  Energy  Design  Update,
August 1998.
“Housewraps or Building Paper? No Perfect Answer,” Energy Design Update, July 1998.
“Housewrap vs. Felt,” Paul Fishett, Journal of Light Construction, November 1998.

PRODUCT  INFORMATION
The Celotex Corp., P.O. Box 31602, Tampa, FL 33631; 800–CELOFAX (Tuff Wrap).
DuPont, P.O. Box 80705, Wilmington, DE 19880–0705; 800–44–TYVEK (Tyvek Homewrap).
Owens Corning, Fiberglass Tower, Toledo, OH 43659; 800–GET–PINK (Pinkwrap).
Raven Industries, P.O. Box 5107, Sioux Falls, SD 57117–5107; 800–635–3456 (Rufco Wrap).
Simplex  Products  Division,  P.O.  Box  10,  Adrian,  MI  49221-0010;  517–263–8881  (R-Wrap,  Barricade
Building Paper).

38
6 I N S U L AT I O N
ESSENTIAL  KNOWLEDGE
Insulation is one element in a tightly knit construction system intended to improve indoor comfort and
reduce energy consumption. In rehab work, installing insulation or improving existing insulation levels
will be critical in providing comfort. Insulation should never be applied without considering its effect on
other aspects of construction. Some factors to consider when evaluating wall insulation are density and
compressibility, air leakage, moisture control, fire safety, and wall construction in existing homes.
Each type of insulation has a density at which its R-value per inch is greatest, but reaching this
density is not always cost-effective. For 31/2-inch thick fiberglass batts, an R-13 batt contains 40 percent

FIGURE 1 TYPICAL FIBERGLASS BATT DENSITIES AND VALUES

more material, and an R-15 batt 180 percent more material, than an R-11 batt (Fig. 1).
To achieve a desired overall R-value for dry blown-in insulation, and to prevent settlement, the
installed density must be above a recommended minimum. For convenience in comparing estimates or
monitoring the installation, have the bidder or installer calculate the number of bags required to achieve
the required density.
Unless insulation completely fills all the wall cavities, air leakage can bypass the insulation and
create a risk of condensation. Reducing air leakage is an inseparable part of insulating: you should not do
one without doing the other. Typical locations for air leakage through walls are at the sill, the wall plates,
vertical corners, around openings, and at electrical devices.
Before filling stud cavities of older homes with blown-in or foamed-in-place retrofit insulation,
explore the construction. Stud cavities are often interrupted by blocking half-way up the wall, or in girt-
frame  construction,  by  full-depth  diagonal  corner  braces.  The  outside  walls  may  be  “back-plastered,”
where a hidden layer of plaster creates two parallel cavities within each stud space, neither deep enough
to receive loose-fill insulation. After insulating, an infrared camera scan of the wall will show cavities that
have not been fully insulated. 
Avoid deliberately ventilating walls, since any convective airflow within an outside wall risks con­
densation within the wall and compromises its R-value. Ventilation passages behind the exterior finish are
called for when extreme interior humidity is expected and no vapor retarder can be applied, or where
wood siding is applied directly over exterior foam insulation.  39
TECHNIQUES,  MATERIALS,  TOOLS
Of the innumerable possible combinations of insulating materials and wall configuration, the following list
covers those in common use and uncommon systems that are recommended.

1. INSTALL BATT INSULATION.
Fiberglass insulation is available in batt form, typically sized 93 inches long to fit within the stud-space of an
8-foot wall, or in continuous rolls. Both forms are here referred to as “batt insulation.” It is available in many
thicknesses, densities and in widths to fit framing at 16-inch and 24-inch centers. Unfaced batts can easily be
cut to fit into odd-sized spaces, and are preferred where a continuous membrane vapor retarder is installed.
Residential batts are available faced with kraft-paper and aluminum foil, and commercial batts with a flame-
resistant foil facing are available. All have extended tabs on the facings to secure them in place. When prop­
erly applied, the facings create a partial vapor retarder. Only unfaced or fire-retardant-faced batts can be left
exposed in attics or occupied spaces. If not accurately cut around wiring and other obstacles, faced batts cre­
ate large air cavities that compromise their effectiveness. Tabs can be “inset stapled“ to the sides of the studs,
or  “face  stapled”  to  the  inner  face  (Fig.  2).  Face  stapling  is  preferred  because  it  creates  a  better  vapor
retarder and avoids the air cavity left between the facing and the wall finish when inset stapling. Unless this
cavity is carefully sealed at the top and bottom, it can compromise the wall’s air-tightness and R-value. Staples
into stud faces must be fully set to avoid interfering with drywall installation. In a three-sided wall cavity, fric­
tion-fit unfaced batts, covered with a separate vapor retarder, will typically result in a more effective installa­
tion than will stapled faced batts. In an open wall, the facings are usually necessary for attachment.
ADVANTAGES: An economical, flexible, and well-known product. Provides a dependable thickness of uni­
form density and does not settle, if properly installed. Faced batts can insulate an open stud wall.
DISADVANTAGES:  Effectiveness  requires  careful  installation  to  avoid  gaps  and  consequent  convective
losses. Glass fibers can be irritating if touched or inhaled.

FIGURE 2 FACE STAPLED INSET STAPLED

2. INSTALL ENCAPSULATED FIBERGLASS INSULATION.
Fiberglass insulation is available in rolls or batts, encapsulated with kraft paper or plastic to reduce mechan­
ical irritation to installers. These can be used in any installation where batts are appropriate. One face is
extended to form attachment tabs. The faces on sound control batts do not have a vapor retarder; and some
exterior wall batts have a polyethylene vapor retarder on the flange side. Some encapsulated batts have a Class
A fire-rating and can be left exposed if allowed by local codes. Owens Corning markets Miraflex, made from
loose, virtually itch-free glass fibers with no binder, contained in a plastic sleeve. Cutting encapsulated batts
around obstructions is possible, but exposes the fiberglass. Cutting Miraflex releases the fibers; the product

40
is therefore intended primarily as attic floor insulation. 

ADVANTAGES: deal for rehab contractors. Can be left exposed (check local codes). Flange-attached with

or without a vapor retarder on some products.

DISADVANTAGES: More costly than regular batt insulation. Cutting encapsulated batts exposes the fiber-

glass, and cutting Miraflex releases the fibers.

3. INSTALL BLOWN-IN LOOSE-FILL INSULATION INTO CLOSED STUD SPACES.
Loose-fill insulation (fiberglass, cellulose, or mineral wool) can be blown into closed stud spaces through
openings formed by drilling holes through the interior or exterior finish, or by removing strips of interior or
exterior finish, at the top and bottom of each rafter space. Careful installation is required because material can
bridge over electric lines and other obstructions, causing voids and later settlement. Beware of blocking; blow
into cavities above and below it. At least a moderate amount of pressure is required to produce sufficient den­
sity to inhibit settlement. Fiberglass blown into a 2 by 4 stud cavity at a density of about 1.5 pcf produces R-13
without excess pressure on finishes. In a “dense-pack” installation of cellulose, dry material is applied at high
velocity through a narrow tube inserted through a single hole at the top and extended to the bottom of the cav­
ity. The tube is gradually withdrawn, compacting the material to a density of 3 to 31/2 pcf. “Stabilized” cellu­
lose includes an adhesive, and “Fiberized™” cellulose is made in strands instead of chunks; both processes
are claimed to inhibit or prevent settlement. Insulation packed into and filling wall cavities suppresses air
movement within the cavity, does not create a vapor retarder, but may substantially improve fire safety.
ADVANTAGES: If the cavities are completely filled under sufficient pressure, provides superior insulating per­
formance without settlement, greatly reducing air circulation within the walls, and may improve fire safety.
DISADVANTAGES: Some types of installation may leave voids and/or settle after installation. Blown-in mate-
rials do not form a vapor retarder, and form only a partial air barrier.

4. INSTALL BLOWN-IN OR SPRAYED-ON INSULATION INTO OPEN STUD SPACES.
An inexpensive material can be applied as a membrane over open studs to form “see-through” cavities,
within which any blown-in insulation can be applied under moderate pressure. In Ark-Seal’s Blown-in-
Blanket® (BIBS) system, fiberglass mixed with some water and adhesive is blown through slits cut in a
tightly stretched nylon netting. In Par-Pac’s Dry-Pac Wall System™, dry cellulose is blown at 3 pcf density
into a cavity closed by a reinforced polyethylene vapor retarder (Fig. 3). The material is installed from the

FIGURE 3 BIBS SYSTEM

bottom up to minimize voids and settlement. All such installations will cause the membrane to bulge out;
make sure this bellying does not interfere with drywall installation. Various types of polyurethane- and
polyisocyanurate-based insulations, such as Icynene, can also be spray-applied into stud cavities. A thin
layer of such material can form an air-barrier skin, over which cheaper material can be placed. Excess
41

material must be scraped off, and windows and electrical devices protected or cleaned. Water is mixed

with cellulose in a “wet-spray” application. The water combines with the starch in the cellulose to form a

natural  adhesive,  which  holds  the  material  in  place.  Excess  material  must  be  scraped  off,  but  can  be

reused. The material must dry out before a finish is applied; excessive water can prevent drying and gen­

erate rot or mildew. High-density insulation filling cavities may improve fire safety.

ADVANTAGES: Fills the cavities without settling. Visual inspection is possible to insure filled cavities. Greatly

reduces air circulation within walls. May improve fire safety.

DISADVANTAGES: Bellying of the interior membrane may interfere with drywall installation. Sprayed-on

foam products are more expensive than batt or loose-fill installations, and are messy processes, requiring

cleanup and protection. Excess water in wet-spray applications may lead to rot and mildew.

5. INSTALL RIGID WALL INSULATION. 

A 3/4-inch to 1-inch layer of rigid insulation, typically polyisocyanurate (ISO), molded expanded polystyrene

(EPS), or extruded polystyrene (EPS), is a widely used adjunct to cavity insulation. Where cavity insulation

cannot be installed, rigid foam may be the only way to insulate a wall. It is preferably applied on the outside

of the framing, keeping the framing warm enough in cold weather to prevent condensation within the walls,

and inhibiting thermal short-circuits through the studs. It is also useful on the outside as a base for cement

stucco or extorior insulation and finish systems (EIFS), although the latter should be part of an engineered

system that provides interior drainage. A layer of foam is essential in conjunction with conventional steel

framing to prevent surface condensation. In Gulf-coast climates, a layer of foam behind the interior finish is

preferred over an exterior layer or a layer on both sides of the studs, especially with steel framing. Since foam

cannot be relied upon to resist racking, it must be applied over structural sheathing or in parallel with a 

system of wall shear bracing. Structural sheathing separated from the framing by an outside layer of foam

may not meet code racking requirements (consult with a structural engineer). Celotex makes a structural

polyisocyanurate foam sheathing that, when glued and nailed to the framing, acts as racking bracing. Wood

siding should not be applied directly to foam insulation.

ADVANTAGES: Isolates framing to minimize or eliminate internal condensation and reduce cold bridging

through framing. Can add more than its rated R-value to a wall assembly. 

DISADVANTAGES:  More  costly  per  R  than  fiberglass  insulation.  If  substituted  for  exterior  sheathing,

requires other measures to create racking resistance in the structure. Should not be used with EIFS except

as part of an engineered system with interior drainage. EPS cannot support one-coat cement stucco over

more than 16" stud spacing.

6. INSTALL A RADIANT BARRIER.

While radiant barriers and coatings are commonplace in high-temperature industrial applications (typically

500º F or more), they are marginally effective at ordinary temperatures. To be cost-effective in building appli­

cations, they must have a very low incremental cost (from 2 to 10 cents/sf, depending on the application). Clean,

shiny aluminum foil facing a 3/4 inch or deeper air space can create a radiant barrier. Foil-faced insulation held

back and inset-stapled creates only a marginally effective radiant barrier because the insulation bulges into the

air space, and because the cavity can create heat loss through convection: it is always more effective to fill the

cavity with insulation. If an air space is present for other reasons (for example, the cavity between sheathing and

brick veneer), facing the air space with foil-faced sheathing will add thermal resistance if the material remains

clean. A new form of radiant barrier is Radiance™ paint, which contains aluminum dust.

ADVANTAGES: An easy way to add insulating value at brick cavity walls. 

DISADVANTAGES: Marginally cost-effective; unlikely to be effective if exposed to dirt or condensation. Not cost-

effective in cold climates, except possibly Radiance™ paint. Seldom or never cost-effective if the air space is

deliberately “stolen” from conventional insulation. Foil may create a vapor barrier where one is not desired. 

7. INSTALL A STRUCTURAL INSULATED PANEL WALL.

Rigid  foam  insulation  adhered  to  structural  skins  can  create  a  structural  insulated  panel  (SIP).  SIPs 

provide  a  combination  of  structure  and  insulation.  Depending  upon  the  design,  the  panels  may  be 

42

self-supporting or may be a non-load-bearing exterior skin applied over a post and beam frame. Very tight
joints are crucial, since a small amount of air leakage through a joint is guaranteed to create destructive
condensation at the most critical structural point. Panels are typically fabricated to order and delivered to
the site for quick erection. Acoustical tightness is readily noticeable. 
ADVANTAGES: A high-R wall that can be load bearing and resists racking. Provides excellent acoustical resis­
tance. Allows a high level of prefabrication and fast on-site erection.
DISADVANTAGES: Not yet in common use, and therefore more expensive than ordinary framing. Requires
careful air-sealing at all joints. 

FURTHER  READING
ASHRAE, 1997 Handbook of Fundamentals, Inch-Pound Edition, Chapter 22: Thermal and Moisture Control
in  Insulated  Assemblies—Fundamentals;  Chapter  23:  Thermal  and  Moisture  Control  in  Insulated
Assemblies—Applications;  Chapter  24:  Thermal  and  Water  Vapor  Transmission  Data,  American  Society  of
Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA; 404–636–8400; www.ashrae.org.
“Fiberglass vs. Cellulose: Making the Choice,” Ted Cushman, Journal of Light Construction, Sept. 1995,
pp 27–31.
Energy Source® Catalog; Iris Communications, Inc.; 800–346–0104.
Energy  Star  Fact  Sheets;  Builder  Guides;  U.S.  Environmental  Protection  Agency  (EPA),  Atmospheric
Pollution Prevention Division; 888–STAR–YES.
Home Energy’s Consumer Guide to Insulation; www.homeenergy.org/eehem/96/9609insulation.html.
Residential Energy Efficiency Database (REED); http://139.142.36.88/reed/index.htm.
Sawnee Energy Library; /www.energydepot.com/sawnee/library/library.cfm.
U.S.  Department  of  Energy  (DOE)  Energy  Efficiency  and  Renewable  Energy  Clearing  House  (EREC);
800–363–3732; e-mail: [email protected];  http://erecbbs.nclinc.com.
“Insulation Fact Sheet,” August 1997, Document DOE/CE–0180.
“Loose-Fill Insulations,” May, 1995, Document DOE/GO–10095–060.
“Insulation Materials: Environmental Comparisons,” Alex Wilson, Environmental Building News, Volume
4, Number 1, January/February 1995.
“Insulation Comes of Age,” Alex Wilson, Fine Homebuilding, February/March 1996, No. 100.

PRODUCT  INFORMATION
BATT, SPRAY-ON, AND LOOSE-FILL INSULATION
Cellulose  Insulation  Manufacturers  Association,  136  South  Keowee  Street,  Dayton,  OH  45402;
937–222–2462; www.cellulose.org.
American Rockwool, Inc., P.O. Box 880, Spring Hope, NC 27882; 919–478–5111.
Ark-Seal International, 2190 South Kalamath, Denver, CO 80223; 800–525–8992.
Building Products Division, The Celotex Corporation, P.O. Box 31602, Tampa, FL 33631; 813–873–4000.
CertainTeed Corporation, 750 East Swedesford Road, Valley Forge, PA 19482; 800–523–7844.
GreenStone Industries Inc., 6500 Rock Spring Drive, Suite 400, Bethesda, MD 20817; 888–592–7684.
Icynene Inc., 376 Watline Avenue, Mississauga, ON L4Z 1X2, Canada; 800–946–7325.
43
International Cellulose Corp., 12315 Robin Boulevard, Houston, TX 77245–0006; 800–444–1252.
Johns Manville Corporation (formerly Schuller International Inc.), 717 17th Street, Denver, CO 80202; or
P.O. Box 5108, Denver, CO 80217-5108; 800–654–3103.
Knauf Fiber Glass, 240 Elizabeth Street, Shelbyville, IN 46176; 800–200–0802.
Owens Corning, One Owens Corning Parkway, Toledo, OH 43659; 800–354–PINK or 800–GET–PINK.
Par-Pac™, 4545 East 52nd Avenue, Commerce City, CO 80022; 800–850– 8505.
Rock Wool Manufacturing Co., 203 North Seventh Street, Leeds, AL 35094; 205–699–6121.
Sloss Industries Corporation, 3500 35th Avenue North, Birmingham, AL 35207; 205–808–7803.
U.S. Fiber, Inc., 905 East Martin Luther King Dr., Suite 400, Tarpon Springs, FL 34689; 800–666–4824.
Western Fiberglass Group, 6955 Union Park Center, Suite 580, Midvale, UT 84047; 801–562–9558.

STRUCTURAL INSULATED PANELS
Structural  Insulated  Panel  Association,  1331  H  Street  NW,  Suite  1000,  Washington  D.C.  20005;
202–347–7800; e-mail: [email protected].

RIGID FOAM INSULATION
Expanded Polystyrene Molders Association (EPSMA), 1926 Waukegan Road, Suite 1, Glenview, IL 60025–1770;
800–607–3772.
Polyisocyanurate  Insulation  Manufacturer’s  Association  (PIMA),  1001  Pennsylvania  Avenue,  N.W.,  5th
Floor, Washington, DC 20004; 202–624–2709; www.pima.org.
Celotex Building Products, P.O. Box 31602, Tampa, FL 33631–3602; 813–873–4230.
Dow  Chemical  Company,  Styrofoam  Brand  Products,  2020  Willard  H.  Dow  Center,  Midland,  MI  48674;
800–258–2436.
Johns Manville Corporation (formerly Schuller International Inc.), 717 17th Street, Denver, CO 80202; or
P.O. Box 5108, Denver, CO 80217–5108; 800–654–3103.
Owens Corning, One Owens Corning Parkway, Toledo, OH 43659; 800–354–PINK or 800–GET–PINK.
Tenneco Building Products, 2907 Log Cabin Dr., Smyrna, GA 30080; 800–241–4402.

RADIANT BARRIER PRODUCTS
Energy-Brace™ reflective sheathing, Fiber-Lam, Inc., P.O. Box 2002, Doswell, VA 23047; 804–876–3135.
Radiance™ Low-e interior paint, ChemRex, 889 Valley Park Drive, Shakopee, MN 55379; 800–433–9517.
Thermo-ply™ reflective  sheathing,  Simplex  Products  Division,  P.O.  Box  10,  Adrian,  MI  49221;
517–263–8881.

44

7 VINYL SIDING
ESSENTIAL  KNOWLEDGE
Introduced in the 1960s, vinyl siding has become the leading wall cladding material for siding (60 to 70
percent  of  the  national  residing  market,  and  40  to  50  percent  of  the  national  new  siding  market).
Regionally,  its  most  prevalent  use  is  east  of  the  Mississippi.  Originally  considered  a  relatively  low-per-
forming product that had fading and cold-weather cracking problems, vinyl siding has evolved into a high
performing product with good weatherability and a level of detailing and finish that, in the most sophisti­
cated and innovative examples, comes fairly close in appearance to the wood siding products that it emu­
lates. It is essential, however, that vinyl siding be allowed to expand and contract freely. It is estimated that
over 90 percent of the problems with vinyl siding are caused by a lack of sufficient clearance between the
nail head and the nailing slot or between the siding and trim.
Vinyl siding is made of polyvinyl chloride (PVC) resins with inorganic color pigments, Ultraviolet
(UV) stabilizers, and various plasticizers. It has a typical exposure of 8 or 10 inches plus a fastening tab
(hem), and is commonly available in 12 foot lengths, although longer lengths are available from some
manufacturers. Physical characteristics are established by American Society for Testing Materials (ASTM)
D3679, which sets minimum thickness at 0.035-inch. Thickness is not the only indicator of performance.
The specific PVC formulation, siding profile, and attachment details are also important characteristics. The
industry is reviewing ways to set multiple performance requirements, but at this time siding thickness is
the primary means of differentiating products. 
There  are  three  general  classifications  for  vinyl  siding  based  on  thickness,  with  sub-
classifications for low and high-end products:
TABLE 1
Super Economy Economy Standard Premium Super Premium
0.035" to  0.040" to  0.042" to  0.044" to  0.048" +
< 0.040" < 0.042" < 0.044" < 0.048"

Prices vary accordingly, with some super premium products costing up to twice the cost of super
economy. Most of the material sold is in the economy range. Industry consensus holds that material below
0.040 inch may be too thin to conceal uneven substrates. The super premium products, at 40 percent
thicker, will not necessarily last 40 percent longer than standard products, although they will be straighter,
less wavy, more resistant to impact damage, and may be architecturally more distinctive. Most vinyl siding
is sold as a “commodity” product, in standard economy styles and finishes. However, some fairly recent
evolutions/innovations in vinyl siding have been introduced largely in higher-end products. Many of these
reflect small niche markets today, but the market is becoming more selective and quality conscious:

■ Product formulations: Most manufacturers have continued to refine existing formulas to develop bet­
ter weathering and non-fading characteristics. Non-fading warranties have been introduced that extend the
warranty period. New premium resins are being developed that will allow darker colored panels to per-
form as well as lighter ones. 

■ Finishes: A number of manufacturers have developed low gloss finishes that replicate sanded, sealed,
and painted cedar. Some closely resemble the texture of cedar clapboard and the color of stained siding.
Simulated plain and scalloped cedar shingles and decorative cedar panels, such as Certainteed’s Cedar
Impressions™, made from polypropylene, are also available. Extended warranties are available against
peeling, blistering, rotting, flaking, chipping, cracking, corroding, and excessive fading.

45
■ Profiles and reinforcements: High-end products, such as Wolverine’s Super Premium Portfolio HP™,
provide  thicknesses  up  to  0.055  inch,  deeper  reveals,  reinforced  nailing  hems,  and  stronger  locking
profiles. Wolverine offers a fiberglass reinforcement bar in its Benchmark™ series that overlaps adjacent
panels  and  provides  increased  rigidity.  Wolverine  has  recently  developed  a  flexible  nail  hem  on  its
Millennium™ series that eliminates the conventional slotted hem, making fastening faster and simpler,
reducing  expansion  and  contraction  problems,  and  allowing  the  use  of  stapling  as  well  as  nailing.
Certainteed, Heartland, and Alside also have developed reinforced interlocks (Fig. 1).

■ Insulated siding products: Progressive Foam Products manufactures an insulated contoured underlay­
ment, ThermoWall®, that is designed to go over existing siding products, provide a rigid base for new vinyl
siding and add an R-value of up to 4.2 to the existing wall. The underlayment panels (Fig. 2), 20 inches
high, 48 inches long, and minimum 1/2 inch thick, are profile-specific and have been developed for over

WOLVERINE® MILLENNIUM™ SIDING ALSIDE CENTERLOCK™

BENCHMARK™ LAPLOCK™ CERTAINTEED CERTILOCK™

WOLVERINE® GRIPLOCK™ STANDARD VINYL SIDINGS

46
FIGURE 1
VINYL SIDING LOCKING PROFILES
FIGURE 2, 3 THERMOWALL® ZIP TOOL

750 existing vinyl siding products from different manufacturers. Progressive has helped develop a four-
course profile for VIPCO (a division of Crane Plastics) that is laminated to a vinyl siding panel approxi­
mately 12 feet long by 16 inches high, sold under the name of TechWall™.

■ Trim and accessory panels: A number of manufacturers produce wide window, door, and corner trim
with reveals that eliminate the standard J channel and make the joining of material appear closer to that
of wood siding. Note that siding cannot be butted directly against wood trim without use of a J channel.
Vinyl siding requires trim on outside and inside corners. 

TECHNIQUES,  MATERIALS,  TOOLS


1. REMOVE STAINS FROM EXISTING VINYL SIDING.
Some vinyl siding, which might appear to need replacement, can be rehabilitated by careful cleaning. Vinyl
siding will fade over time, but maintenance and cleaning will prolong the service life and appearance of
the  material.  Vinyl  siding  is  easily  cleaned  with  a  variety  of  approved  cleaners  that  are  formulated  for
specific staining problems. The Vinyl Siding Institute has prepared a comprehensive list of those cleaners
that will remove most stains (see Further Reading). 
ADVANTAGES: A low-cost approach to vinyl siding rehab. 
DISADVANTAGES: Cleaning might not eliminate all staining and will not eliminate fading. 

2. REPAIR EXISTING VINYL SIDING.
Sections of vinyl siding that are buckled, dented, cracked, stained, or otherwise damaged can be easily
replaced by means of a “Zip” tool that slips behind the bottom of the siding panel above the damaged
panel, allowing access to the damaged panel for replacement (Fig. 3). Instructions are provided by the
Vinyl Siding Institute and individual manufacturers (see Further Reading).
ADVANTAGES: Allows portions of vinyl siding to be replaced without complete residing.
DISADVANTAGES: New vinyl replacement siding will not match weathered vinyl siding. Small discolored
sections can be painted with an all-acrylic paint, although the Vinyl Siding Institute does not specifically
endorse painting.

3. REPLACE/COVER EXISTING SIDING WITH NEW VINYL SIDING. 
Existing siding can be prepared in three ways:
1. Strip off existing siding that has deteriorated to the point where it cannot be used as a sub­
strate. This will assure the straightest and flattest application and will allow inspection of the sheathing and
47
insulation, which can be replaced if necessary. Install new vinyl siding as per manufacturer’s installation
requirements. Note that vinyl siding requires a smooth, even, rigid substrate such as plywood, wood com­
position, rigid foam insulation, or fiber sheathing. It cannot be installed directly to structural framing or
it  will  sag  and  deflect  between  framing  members.  (Failure  to  establish  a  smooth  solid  substrate  may 
constitute a misapplication under the terms of the warranty.)
2.  Apply  rigid  or  semi-rigid  (e.g.  FoamCore™ by  International  Paper)  sheathing  to  existing 
siding to provide a smooth substrate. Nail securely through old siding and into framing members. Flash
as necessary around projections and openings.
3 Apply vertical furring strips to old siding to strengthen and straighten uneven surfaces. Then
apply rigid sheathing as described in example 1 above. Vinyl siding cannot be applied directly over fur-
ring. Residing over existing material will require jamb and trim extensions.
Vinyl siding should be applied with corrosion resistant nails (aluminum or galvanized) with a
minimum  3/4 inch penetration into wood or wood composition substrate. When foam sheathing is used
directly over studs, nails must penetrate studs by at least 3/4 inch. Nails should be driven so that the heads
are 1/16 to 1/8 inch away from the slotted nailing tab to allow for shingle movement. Pneumatic staplers or
nailers can be used but can bind siding more easily (especially staples) than hand nailing, unless used by
an experienced installer. Individual manufacturers’ installation guidelines should be followed carefully.
ADVANTAGES: Better quality vinyl siding replicates wood siding appearance. New formulations, textures,
colors, and details are now available that allow more choice and improve the appearance of most archi­
tectural styles. A relatively low maintenance product.
DISADVANTAGES:  Vinyl  siding,  especially  the  thinner  products,  might  appear  wavy  and  will  reflect  the
irregularity of some substrates. Expands and contracts more than other siding materials. Thinner gages
are  susceptible  to  “oil  canning”  and  may  become  brittle  over  time.  Overdriven  or  improperly  placed 
fasteners  can  resist  siding  movement  and  cause  buckling.  Colors,  especially  dark  ones,  will  fade  over
extended periods. Vinyl siding is not weatherproof and requires a weather barrier. 

FURTHER  READING
“Application Instructions,” Vinyl Siding Institute, the Society of Plastics Industry Inc., 1994.
“Cleaning of Vinyl Siding,” Vinyl Siding Institute, the Society of Plastics Industry Inc., 1994.
“Fire Properties,” Vinyl Siding Institute, the Society of Plastics Industry Inc., 1994.
“Installation  Guide  for  Vinyl  Siding  and  Accessories,”  Wolverine/Certainteed,  1998;  888–838–8100;
www.vinylsiding.com. 
“Vinyl Siding,” George Schamback, The Journal of Light Construction, June 1997, pp. 27–31.

PRODUCT  INFORMATION
Vinyl Siding Institute, 1801 K Street, Suite 600K, Washington, DC 20006; 888–FORVSI–1; www.vinylsid­
ing.org. (A complete list of member companies, their web sites and products, can be obtained from the
Vinyl Siding Institute.)
Progressive Foam Products, Beach City, Ohio; 800–860–3636; www.progressivefoam.com.
TechWall™–VIPCO, 1441 Universal Drive, Columbus, OH 43216; 800–366–8472; www.crane-plastics.com.
Foam-Core™–International  Paper,  P.O.  Box  1839,  Statesville,  NC  08687–1839;  800–438–1701; 
www.ipaper.com.

48
8 M E TA L   S I D I N G
ESSENTIAL  KNOWLEDGE
Aluminum and steel siding gained great popularity in the 1950s and 1960s as the most durable and cost-
effective materials for replacing or covering up old, deteriorating siding. It frequently contained thin foam
inserts which, manufacturers claimed, greatly enhanced the insulating qualities of the material. While the
new siding may have been effective in reducing air infiltration, the thinness of the insulation and the great
thermal conductivity of metal made this siding a poor performer in terms of energy.
The use of aluminum and steel siding has drastically declined in recent years with the emergence
and popularity of vinyl and fiber cement siding products, to the point where metal siding now accounts
for only about 1 percent of the new siding market. Primary markets include the Midwest (particularly for
steel  siding)  where  cladding  must  resist  hailstorms  and  temperature  extremes.  In  metropolitan  areas
where  local  codes  require  noncombustible  building  materials,  metal  siding  is  an  obvious  choice.  The
plethora of existing metal siding makes it a prime candidate for repair or replacement in rehab work.

TECHNIQUES,  MATERIALS,  TOOLS


1. MAINTAIN METAL SIDING.

Under normal conditions, metal siding will require only occasional washdown with a garden hose and a
soft bristle brush. If the siding is moderately dirty, use a solution of 1/3 cup of a mild clothwashing deter-
gent to a gallon of water. For heavier dirt and stains the non-abrasive detergent can be mixed with 2/3 cup
trisodium  phosphate  (Soilax,  or  Spic-N-Span  for  example)  to  a  gallon  of  water.  Use  mineral  spirits  to
remove caulking compounds, tar and similar substances. Clean from bottom to the top. Rinse thoroughly.
Avoid abrasive cleaners and strong solvents.
ADVANTAGES: Maintenance is simple and effective.
DISADVANTAGES: Will not remove fading and severe caulking.

FIGURE 1 REPLACEMENT OF SIDING 49
FIGURE 2 ON-SITE ROLL FORMING

2. REPAIR METAL SIDING.

The replacement of metal panels is relatively simple: 1. Cut the damaged panel along its center with a util­

ity knife or metal shears. Remove and discard the bottom section; 2. Cut and remove the top lock or a new

panel; 3. Apply a heavy bead of Gutterseal (Alcoa or other brand) the full length of the defective panel; 4.

Install the new panel over the Gutterseal. Apply pressure with the palm of the hand. Do not nail the panel.

(Fig. 1)

ADVANTAGES: Repair is relatively simple procedure.

DISADVANTAGES: Color of replacement will not match original.

3. REPLACE EXISTING SIDING WITH STEEL SIDING.

Considered by some in the industry to be one of the highest performing siding products on the market

because of its resistance to cracking, bending, high winds, and high temperatures, steel continues to have

a strong niche market. Steel can be placed directly over existing siding materials, over insulated sheath­

ing on top of existing material, or attached to furring strips placed on masonry or uneven walls. It typi­

cally comes in 12-foot lengths and panel widths of double 4 or 5-inch exposures, with a PVC or acrylic

finish. A number of companies, such as ABC Seamless, provide seamless steel siding through franchised

installers. It is roll-formed on site to eliminate vertical joints (Fig. 2). 

ADVANTAGES:  One  of  the  strongest  and  most  damage-resistant  siding  products  available;  lays  flat  and

straight against most substrates; color finishes warranted against fading and peeling; noncombustible; can

be touched up with paint. 

DISADVANTAGES: Approximately double the cost of standard vinyl siding; 30 percent more expensive than

aluminum siding. Fewer profiles, styles, colors, trim, and accessories than vinyl siding. 

4. REPLACE EXISTING SIDING WITH ALUMINUM SIDING.

Aluminum continues to have some niche market appeal, although its use is diminishing. Aluminum siding

is typically available in 12-foot lengths and panel widths of double 4 or 5-inch exposures, with a PVC or

acrylic finish. The most popular color is white, but a limited color palette is available. Like steel siding,

aluminum can be applied directly over wood-sided walls that are sound and straight, over insulated sid­

ing, and over furring strips. 

ADVANTAGES: Lays straight over most substrates; less likely to show waviness than vinyl siding; lightweight,

noncombustible, durable, and easy to clean. 

DISADVANTAGES: More costly than vinyl; dents relatively easily; comes in limited styles and colors. 

50

PRODUCT  INFORMATION
ABC Seamless, 3001 Feichner Drive, Fargo, ND 58103; 701–293–5952.
Alcoa  Building  Products,  P.O.  Box  57,  1501  Michigan  St.,  Sidney,  OH  45365–0057;  800–962–6973;
www.alcoahomes.com.
Alside, 373 State Road, P.O. Box 2010, Akron, OH 44309; 800–257–4335.
EDCO, 8700 Excelsior Boulevard, Hopkins, MN 55343; 800–333–2580.
Norandex/Reynolds Distribution Co., 8450 South Bedford Road, Macedonia, OH 44056; 330–468–2200;
www.norandex.com; www.reynoldsbp.com.
Reynolds Building Products, One Norandex Place, Macedonia, OH 44056; 330–468–2200.
United States Seamless, Inc., 2001 First Ave. N., P.O. Box 2426, Fargo, ND 58108–2426; 701–241–8888;
www.usseamless.com.

51
9 WOOD SHINGLES
& SHAKES
ESSENTIAL  KNOWLEDGE
Wood shingles and shakes (thicker versions of shingles) have been used for siding for more than 300
years. Today, most of this material is milled in Canada and is made of Western red cedar, Eastern white
cedar, or Alaskan yellow cedar. Pressure-preservative-treated Southern yellow pine is also used for shakes
on a limited, regional basis. Western red cedar weathers a darker gray than the other two materials. A few
mills make redwood shingles, but they are not as popular as cedar because they weather considerably
darker. Cedar shingles and shakes are warranted against material defects for a minimum of 20 years (30
if pressure-treated with CCA) by members of the Cedar Shake and Shingle Bureau (CSSB).
Western red cedar shingles are available in a variety of grades, including No. 1 BLUE LABEL (100
percent heartwood, 100 percent clear, 100 percent end grain) and No. 2 RED LABEL with some flat grain
and  limited  sapwood.  Other  grades  are  available  for  secondary  structures,  economy  installations,  and
undercoursing. No. 1 is the preferred grade for both roofing and siding, but No. 2 grade is also used for
siding because the weathering conditions are not as extreme as roofing.
Eastern  white  cedar  shingles  (increasingly  coming  from  small,  second  growth  trees)  are  not
available in 100 percent edge grain, and are graded by knot content. Grade “A” BLUE LABEL is all heart-
wood with no imperfections; Grade “B” RED LABEL allows imperfection such as knots on non-exposed
parts and has a recommended maximum exposure of 6 inches. Grades “A” and “B” are recommended
for siding. Grade “C” BLACK LABEL is an economy grade that allows sound knots on exposed portions,
and has a rustic appearance. Grade “D” is a utility grade for underlayment. Eastern white cedar shingles
are available prefinished from Sovebec, Inc. (Eastern Canada’s largest consortium of white cedar mills)
in a tailored rebutted and squared configuration with a peroxide bleaching agent and latex stain called
“Ultra  Bleach,”  which  accentuates  and  accelerates  the  silver  gray  weathered  appearance  (see  Product
Information).
Western red cedar shakes are available in a variety of textures and finishes including: machine
grooved; handsplit face and resawn back; taper sawn on both sides (resembling an extra-thick shingle);
taper split by hand both sides and straight-split by machine both sides. See the Cedar Shake and Shingle
Bureau Design and Application Manual for detailed specifications on cedar siding.

TECHNIQUES,  MATERIALS,  TOOLS


1. REPLACE INDIVIDUAL CEDAR SHINGLES.
If a small number of individual shingles are badly curled, cracked, or missing, they can be removed and
replaced relatively easily: Cut nails holding damaged shingles with a hack saw blade. Split shingles with a
chisel and remove pieces. Cut a new shingle to fit with a 1/8 to 1/4 inch clearance each side.
ADVANTAGES: An inexpensive way to repair existing siding.
DISADVANTAGES: Will not work with a large area of defective shingles.

2. RESIDE WITH NEW CEDAR SHAKES AND SHINGLES.
Certain types of existing siding including vertical wood siding or paneling, and existing wood clapboard that
are flat and in sound condition, can be left in place and new shingles applied over them. Shingles can be
applied over beveled siding by filling in the low points of the wall with low grade timber strips  (called
52
“horse feathers”) and thereby increasing the potential nailing surface, or by nailing the shingles or shakes
to the high points of the bevels of each course of the old wall (Fig. 1). However, many shingle manufactur­
ers recommend the use of furring strips or a plastic mesh product such as Cedar Breather™ be used to
allow for air circulation and to reduce the potential of excessive moisture build-up behind the shingle (Fig.
2). If the existing siding is stucco or masonry, or if the surface is uneven, horizontal, or a combination of
horizontal and vertical, furring is necessary to flush out the wall, allow for air circulation, and to provide a
nailing surface for the new siding (Fig. 3). If the existing siding is substantially deteriorated, removal of the
shingles allows for the inspection, removal, and reinstallation of existing insulation, sheathing, flashing,
caulking, building paper, or housewrap as necessary. If the sheathing is nonstructural or foam, new shingles
should be fastened to furring that is laid over the sheathing. Furring is typically 1 by 3 or 1 by 4 material
(Fig. 4). Wherever possible, butt lines should align with tops or bottoms of windows or other openings for
appearance. Shingle exposure should be consistent. Corners can be butted against corner boards or laced
together on outside and inside corners, or mitered on outside corners (Fig. 5).
ADVANTAGES: An attractive, natural material for both traditional and contemporary buildings. Can be treated
with a variety of coatings and preservatives or left to weather naturally. A sustainable material that comes from
renewable sources. Residing over existing wall eliminates the time and expense of removing existing siding. 
DISADVANTAGES:  More  costly  than  other  siding  material.  Can  weather  unevenly  in  certain  conditions.
Combustible unless pressure-treated with fire retardants. Some warping and cupping will occur.

FIGURE 1, 2 BEVELED SIDING DETAIL CEDAR BREATHER

FIGURE 3, 4 MASONRY DETAIL STUCCO DETAIL 53


� � � � �
a. Shingles butted against corner boards
b. Shingles butted against square wood strip on inside corner, flashing behind
c. Laced outside corner
d. Laced inside corner with flashing behind
e. Mitered corner

FIGURE 5 CORNER DETAILS

FURTHER  READING
Cedar  Shake  and  Shingle  Bureau  Design  and  Application  Manual  for  Exterior  and  Interior  Walls,
Cedar Shake and Shingle Bureau, 1991. 
Cedar Shake and Shingle Bureau Membership Directory and Buyers Guide, Cedar Shake and Shingle
Bureau, Jan. 1998.
A Guide to Southern Pine Shakes, Southern Forest Products Association, Kenner, L.A., 1994.
The Sovebec Guide to Installing Eastern White Cedar Shingles, Charney, Canada: Sovebec, Inc. 

PRODUCT  INFORMATION
Cedar Breather™, Benjamin Opdyke, Inc., 65 Steamboat Drive, John Fitch Industrial Park, Warminister,
PA 18974–4889; 800–346–7655.
Cedar Shake & Shingle Bureau, P.O. Box 1178, Sumas, WA 98295; 604–462–8961; www.cedarbureau.org.
Sovebec Eastern White Cedar, Sovebec, Inc., 9201 Centre Hospitalier Blvd., Charny, Quebec, Canada G6x
1L5; 418–832–1456.

54
10 S O L I D   W O O D
SIDING
ESSENTIAL  KNOWLEDGE
Solid wood siding (particularly beveled siding such as clapboard) has been popular in the U.S. for the past
300 years. The use of wood siding has increased somewhat recently, according to the Western Red Cedar
Lumber Association. However, its use is expected to decline as lumber becomes more costly, as quality
materials become harder to obtain, and as other similar looking and less expensive materials become
more popular (such as vinyl and fiber-cement siding).
The large majority of solid wood siding comes from the Western United States and Canada and is
made of Western red cedar. A small portion is also made from Western redwood, and is available from indi-
vidual mills. Solid wood siding from other softwoods such as vertical grain Western Douglas Fir is occa-
sionally available, but in decreasing amounts. Some Eastern mills produce siding from softwoods such as
white pine and spruce. Wood siding is usually treated with a protective coating such as a semi-transparent
or  opaque  stain  or  paint.  Individual  industry  associations  have  their  own  finishing  recommendations 
(see Further Reading).
Most bevel siding (the most popular form of solid wood siding) is made from resawn lumber (1
inch thick boards that are sawn from logs and then cut diagonally on a band saw. Depending on where
the 1 inch boards are cut, resawn lumber can be vertical grain, curved grain, or flat grain. Quartersawn
(also known as “radial sawn”) siding is made from cuts radiating out from the center of a log, with the
result that each piece is vertical grain (Fig. 1). Vertical grain siding is better at resisting warping and twist-
ing. Curved and flat grain siding tends to twist opposite to the curve of the growth ring. Vertical grain sid-
ing also takes and holds paint better than flat grain because the maximum number of grain surfaces is
exposed and acts as capillaries absorbing paint or stain for better adhesion. Since vertical grain is more
stable than flat grain, the paint is also less stressed by twisting.

FIGURE 1 GRAIN CONFIGURATION AND SHRINKAGE CHARACTERISTICS

55
TECHNIQUES,  MATERIALS,  TOOLS
1. REPAIR/REPLACE DAMAGED PIECES OF EXISTING BEVEL WOOD SIDING.
Individual pieces of bevel wood siding can easily be removed and replaced by cutting the nails holding the
damaged sections with a hacksaw blade, and then by wedging and sawing the damaged sections out. New
material can then be installed to butt existing material and fastened into place. 
ADVANTAGES: Most economical repair.
DISADVANTAGES: Will not work with large areas of deteriorated material, which will have to be stripped
down to the sheathing or structure.

2. REPLACE DETERIORATED OR DAMAGED SIDING WITH NEW WESTERN RED
CEDAR BEVEL SIDING.
Resawn Western red cedar bevel siding has either two textured sides, or one textured and one smooth
sanded side, depending on grade. Clear bevel siding results in the highest quality appearance with no vis­
ible knots. Bevel siding is available in plain bevel and rabbeted bevel (Fig. 2). Plain bevel is the most pop­
ular. Rabbeted bevel lays flatter on the wall and is somewhat easier to nail, but it has a less pronounced
shadow line. Bevel siding ranges in exposure from 4 to 12 inches; with a butt thickness ranging from 1/2
to 7/8 inch. Red cedar bevel siding is available in six traditional grades: Clear V.G. Heart (smooth face, all
vertical grain); A Clear (mixed grain); Rustic (some knots, sawn texture); B Clear (more knots and other
growth characteristics); Select Knotty (significant sound and tight knots); Quality Knotty (considerable
knots); and Architect Knotty Bevel Siding (comes with a variety of knots and other growth characteristics
and is factory primed). Bevel siding is also available finger-jointed in lengths up to 16 feet in clear and
knotty grades and in smooth, resawn, and combed (multiple grooved) textures.

PLAIN RABBETED RABBETED TWO LAP DROP


SAW-TEXTURED SAW-TEXTURED

FIGURE 2 BEVEL SIDING

A number of mills have arrangements with paint/stain companies, including Olympic, Cabot, and
Sherwin Williams, which will provide 5-year warranties for factory-applied primer coat, increased to 15
years after the field application of an approved topcoat. If the siding is recoated before the 15-year war­
ranty is over, it can be extended another 15 years for up to 30 years. Although some lower grades are used
in conjunction with some extended warranty painting programs, vertical grain cedar will perform the best
over an extended period (see Product Information).
Bevel siding can be applied directly, over building paper or house wrap to solid siding or sheath­
ing, or to insulating sheathing if special application requirements for the insulating sheathing are adhered
to (see Further Reading). It can also be applied to furring over masonry (on uneven walls or to allow for

56
the ventilation of the inside face of the cedar). Face nailing of bevel siding is recommended as blind nail-
ing will split the thin, feathered portion of the shingle (Fig. 3). Stainless steel nails are recommended,
especially in areas near the ocean. Hot-dipped galvanized or aluminum nails are acceptable in less cor-
rosive environments. A variety of inside and outside corner details is possible (Fig. 4). Mitered corners
are usually caulked and can separate if the wood is not properly seasoned and knots have been allowed
to get wet prior to application. Corner boards are a good alternative. Non-hardening caulks are recom-
mended, including polyurethane, polysulfide, or latex-silicone. For more information on installation refer
to Installing Cedar Siding (see Further Reading).
ADVANTAGES: Western red cedar bevel siding has natural decay resistance, dimensional stability, worka-
bility, and paintability. Up to 30-year warranties available from paint companies make painted bevel sid-
ing competitive with other siding products. Available in vertical grain and in a variety of sizes, lengths (up
to 16 feet), and finishes. 
DISADVANTAGES: Will deteriorate and discolor over time if not maintained properly. Expands and con-
tracts  with  changes  in  humidity  and  will  shrink  over  time,  causing  vertical  joints  (which  should  be
beveled) to open. May cup and twist, especially if flat grain is used instead of vertical grain. Combustible
material; more costly than other siding products. 

FIGURE 3 FACE NAILING OF BEVEL SIDING

FIGURE 4 CORNER DETAILS

57
3. REPLACE DETERIORATED OR DAMAGED SIDING WITH NEW WESTERN
REDWOOD BEVEL SIDING.
Redwood bevel siding has all of the favorable attributes of cedar bevel siding, but it is less available nation-
ally and usually more costly than cedar. It comes in a variety of grades including Clear All Heart (all heart-
wood and free of knots); Clear (some sapwood and some small, tight knots); B Heart (a limited number
of tight knots and other characteristics); B Grade (similar to B Heart except that it permits sapwood as
well as heartwood). All these grades are available “certified kiln dried,” recommended for top perfor-
mance and minimal shrinkage. Clear or Clear All Heart may be ordered either flat grain or vertical grain
(recommended  for  best  performance).  Rustic  grades  are  also  available.  Redwood  bevel  siding  comes
plain and rabbeted, smooth and rough sawn, and in a full range of sizes from 1/2 by 3 1/2 inches to 3/4 by
10 inches. Thinner widths are less likely to shrink and split than the wider widths. Redwood takes paint
well, but individual mills haven’t been as aggressive as the cedar mills in developing warranty programs
with the leading paint companies. Redwood bevel siding is applied and finished in the same manner as cedar. 
ADVANTAGES: Natural decay resistance, dimensional stability, paintability, and workability. Available in a
variety of finishes, grains, sizes, and styles. 
DISADVANTAGES: Will deteriorate and discolor over time if not maintained properly. Expands and con-
tracts  with  changes  in  humidity  and  will  shrink  over  time,  causing  vertical  joints  (which  should  be
beveled) to open. May cup and twist, especially if flat grain is used instead of vertical grain. Combustible
material; more costly than other siding products.

4. REPLACE DETERIORATED OR DAMAGED SIDING WITH NEW QUARTERSAWN
SPRUCE OR PINE BEVEL SIDING. 
Quartersawn Eastern spruce or pine bevel siding is available from the Granville Mfg. Co. The bevel siding
comes in 1x Clear (clear, unmarked, or exposed section of siding); 2x Clear (up to one knot or blemish
per piece); Cottage (not more than three knots or blemishes, no loose knots). Available in sizes from 7/16

FIGURE. 5 NON-BEVEL WOOD SIDING
by 4 to 6 inches and up to 6 feet long. The material comes unpainted, primed, or painted. 
ADVANTAGES: Vertical grain resists twisting and warping and accepts paint well. Authentic manufacturing
meets all colonial reproduction specifications. Less costly than Western red cedar or redwood; long lifespan. 
DISADVANTAGES: Requires maintenance and repainting. Available only in relatively short lengths (which
shrink less). Will not match resawn siding. Available only in 21/2 to 4-inch exposures. Combustible material.

5.  REPLACE  DETERIORATED  OR  DAMAGED  SIDING  WITH  NON-BEVEL  SOLID


WOOD SIDING. 
Non-bevel wood siding types include board and batten, drop siding, shiplap, tongue-and-groove, and vari­
ations of these types (Fig. 5). Many, including tongue-and-groove and shiplap, can be installed horizon-
tally in the same manner as bevel siding, and vertically with blocking between studs, or over horizontal
furring strips. The grades of the siding products are similar to those for bevel siding. For detailed sizes
and specifications (see Further Reading and Product Information). 
ADVANTAGES: A wide variety of distinctive, historically correct products for both traditional and contem­
porary use. Available from individual suppliers with vertical grain and extended painting warranties. 
DISADVANTAGES: Requires periodic maintenance; more costly than other siding products; combustible. 

FURTHER  READING
Certified  Kiln  Dried  Siding  Applications,  Novato,  CA:  California  Redwood  Association,  1995;
888–225–7339; www.calredwood.org. 
Designer’s  Handbook,  Vancouver,  BC: Western  Red  Cedar  Lumber  Association,  Nov.  1997;
604–684–0266; www.wrcla.org.
Guidelines for Installing and Finishing Wood and Hardboard Siding Over Foam Sheathing, American
Forest and Paper Association; 202–463–2700; www.afandpa.org.
Installing Cedar Siding, Western Red Cedar Lumber Association; 604–684–0266; www.wrcla.org. 
Natural Wood Siding—Technical Guide, Portland, OR: Western Wood Products Association, May 1998;
503–224–3930; www.wwpa.org. 
Redwood  Architectural  Guide,  Novato,  CA:  California  Redwood  Association,  1998;  888–225–7339;
www.calredwood.org.
Redwood  Lumber  Grades  and  Uses,  Novato,  CA:  California  Redwood  Association,  Dec.  1995;
888–225–7339; www.calredwood.org.
Specifying  Cedar  Siding,  Vancouver,  BC: Western  Red  Cedar  Lumber  Association,  May  1998;
604–684–0266; www.wrcla.org. 
Using Redwood Siding Over Rigid Foam Insulation, Novato, CA: California Redwood Association, Sept.
1994; 888–225–7339; www.calredwood.org.

PRODUCT  INFORMATION
Granville Manufacturing Co., Granville, VT 05747; 802–767–4747; quartersawn spruce and pine clap-
board siding.
Siding 2000, pre–finished cedar siding: Coastal Forest Products, 451 South River Road, P.O. Box 10898,
Bedford, NH 03110; 800–932–WOOD.
Skookum Lumber Co., Box 1398, Olympia, WA 98507–1398; 360–352–7633 (cedar siding).
Step Saver Siding: Factory Primed Western Red Cedar; PPG Industries, Inc., 1 PPG Place, Pittsburgh, PA
15272; 800–441–9695; www.ppgaf.com.
59
11 H A R D B O A R D
SIDING
ESSENTIAL  KNOWLEDGE
Hardboard siding was first developed by William Mason in 1922. The product is made of wood chips con­
verted into fibers, combined with natural and synthetic binders, bonded under heat and pressure. The
early success of this material led to a proliferation of hardboard manufacturers in the early 1950s when
the original patents expired. More than a score of companies were producing hardboard siding by the
1970s  when  the  EPA’s  newly  declared  environmental  restrictions  on  the  dumping  of  waste  water  from
hardboard’s wet manufacturing process led to the closing of a number of plants that did not have the space
or  resources  to  make  required  changes.  By  the  mid-1980s  hardboard  siding  accounted  for  about  30 
percent  of  the  United  States  residential  siding  market.  Today,  hardboard  siding’s  market  share  has
declined to approximately 15 percent. The number of current manufacturers has been reduced to six. The
constricted market is due to the growth in use of other materials such as vinyl siding, exterior insulation
and finish systems (EIFS), and fiber-cement siding.
There has been considerable publicity about class action lawsuits against certain manufacturers
regarding  the  material’s  performance  when  exposed  to  moisture.  Manufacturers  have  countered  that,
while lapses in quality control may have occurred, hardboard has a long history of good performance and
that the majority of problems is due to inadequate field supervision (particularly regarding incorrect flash­
ing, caulking, nailings, and painting) by installers around windows, doors, deck terminations, and other
potential moisture entry points, and the lack of sufficient maintenance on the part of homeowners. 
The majority of the class action lawsuits has been settled, and the major manufacturers continue
to produce and sell hardboard siding with limited 25- to 30-year warranties. Some products are under-
going continued design improvements, others have changed relatively little over the years. Masonite Corp.,
for example, has developed a new lap siding product called HiddenRIDGE™ with concealed fasteners and
interlocking design that speeds installation and provides level alignment (Fig. 2).

TECHNIQUES,  MATERIALS,  TOOLS


1. REPAIR EXISTING HARDBOARD LAP SIDING.
Small sections of damaged or deteriorated lap siding can be cut out and replaced with matching profiles rel­
atively easily with conventional carpentry tools, including handsaws and power saws. Deteriorated sheathing
should be replaced as required. Panel siding sections can be repaired as well, but with greater difficulty. 
ADVANTAGES: Most economical repair. 
DISADVANTAGES: Large areas of damaged material have to be stripped down to sheathing or structure.
Repaired sections may not exactly match existing siding.

2. REPLACE EXISTING SIDING WITH NEW HARDBOARD LAP SIDING.
Lap siding is available in  7/16 and  1/2 inch thicknesses and in a wide variety of configurations including
shiplap siding 12 and 16 inches wide in lengths up to 16 feet with varying profiles, as well as conventional
6, 8, or 12 inches wide lap siding made to look like beveled siding (Fig. 2). Most products are pre-primed
and  require  two  coats  (4  dry  mils)  of  field  painting.  Masonite  offers  a  completely  pre-finished,
“Colorlock” siding that comes with a 15-year limited warranty on the finish. Lap siding can be applied over
60
SHIPLAP SIDING

FIGURE 1 LAP SIDING COLORLOK SIDING

SHIPLAP SIDING LAP SIDING

FIGURE 2 HIDDEN RIDGE

existing sound and level siding, over solid or insulating sheathing, directly over studs 16 inches o.c. with
an approved water-resistant barrier, or over furring strips. Staples, t-nails, or bugle head nails are not rec­
ommended. Hardboard, as all materials, will expand and contract with temperature and humidity varia­
tions. A minimum  3/16 inch space is recommended between the siding and windows, door frames, and
corner  boards  and  1/16 inch  between  vertical  butt  joints,  which  must  fall  on  studs.  All  joints  must  be
caulked with non-hardening, mildew-resistant exterior grade sealant. 
61
ADVANTAGES: Hardboard lap siding has been used successfully for over 50 years and remains the pre­
ferred siding material in some markets. Available in a wide variety of profiles, textures, and styles that
accurately simulate the appearance of wood products. Easily worked and handled. A consistent product
with no surface defects. Available in lengths up to 16'. Less costly than solid wood siding products.
DISADVANTAGES: More susceptible to moisture-related problems than other siding materials. Requires
careful storage and protection during construction. Should not be applied over wet sheathing. Requires
careful attention to fastening, caulking, and painting recommendations. Long lengths of siding may buckle
due to expansion. Requires periodic inspection and maintenance of caulking and painting. 

3. REPLACE EXISTING SIDING WITH NEW HARDBOARD PANEL SIDING.
Of the hardboard siding sold, panel siding represents about a third. It is available in 4x8 and 4x9 square-
edge panels (for board and batten applications) and shiplap-edge panels. The panels come in a variety of
textures and groove configurations that simulate vertically applied wood boards. The material is also avail-
able  without  grooves  in  a  stucco  appearance.  Temple-Inland  offers  a  16  by  48-inch  panel  called
“Shadowround”  that  simulates  scalloped  shingles.  Hardboard  panels  may  be  applied  to  sheathed  or
unsheathed walls with studs no more than 24" o.c., or over sound flat existing siding. Panel edges must
fall on and be nailed to framing members. Horizontal joints must have adequate blocking and be over-
lapped a minimum of 1" or be provided with Z-shaped preformed flashing. The material is available 
pre-primed for field painting. 
ADVANTAGES: A consistent material without knots, raised grain, checks, or other surface defects. Takes
paint well and has been used successfully for many years when properly installed and maintained. Can
provide shear resistance when installed directly over studs. Available in a variety of attractive patterns and
finishes. Easily worked and handled. 
DISADVANTAGES: Requires careful storage and protection during construction. Requires careful attention
to  fastening,  caulking,  and  painting  requirements.  Requires  periodic  inspection  and  maintenance  of
caulking and painting. 

FURTHER  READING
ANSI/AHA 135.6-1990 Hardboard Siding, Palatine, IL: American Hardboard Association, 1998.
Maintenance Tips for Hardboard Siding, Palatine, IL: American Hardboard Association, 1997.
Recommended Basic Application Instructions for Hardboard Siding, Palatine, IL: American Hardboard
Association, 1994. 
Today’s Hardboard, Palatine, IL: American Hardboard Association, February 1998.

PRODUCT  INFORMATION
American Hardboard Association, 1210 West Northwest Highway, Palatine, IL 60067; 847–934–8800.
Hardboard Manufacturers:
ABT Building Products Corp., 3250 West Big Beaver Road, Troy, MI 48084; 810–649–3300.
Collins Products, LLC, P.O. Box 16, Klamath Falls, OR 97601; 541–883–4853.
Forestex Co., P.O. Box 68, Forest Grove, OR 97116; 503–357–2131; www.stimsonlumber.com.
Georgia Pacific Corp., 133 Peachtree St., NE, Atlanta, GA, 30303; 800–284–5347; www.gp.com.
Masonite Corp., 1 South Wacker Drive, Chicago, IL 60606; 312–750–0900.
Temple–Inland Forest Products Corp., P.O. Drawer N, Diboll, TX 75941; 409–829–5511.

62
12 E N G I N E E R E D
WOOD SIDING
ESSENTIAL  KNOWLEDGE
Louisiana-Pacific (the largest producer of oriented strand board (OSB)) introduced Inner-Seal™ OSB 
siding  in  the  mid-1980s  as  an  economical  alternative  to  conventional  wood  siding  products  that  had
become more costly due to rising lumber prices. While the material proved popular with builders, some
performance problems arose, particularly in humid environments such as the Northwest and Southeast.
Where nail holes, material surfaces, and edges were not adequately painted or sealed, water penetrated,
causing the OSB siding to swell and expand. Some OSB siding deteriorated due to rot, fungus, and inva­
sion by insects, in some cases causing damage to sheathing beneath. A number of class action lawsuits
were brought against the manufacturer, and L-P has settled these claims.
Since then, L-P has re-engineered the material and has reintroduced it as a “treated engineered
wood product” instead of an OSB product, offering bevel-edged siding in 16-foot lengths with 6, 8, 9 1/2,
and 12 inch widths; and 4 by 8 to 4 by 16 panels. The composition and production process have been
substantially revised. The binder has been changed from a phenolic to methylene diphenyl diisocyanate
(MDI), which is more water resistant and provides a stronger bond to the wood flakes, therefore reduc­
ing the swelling and expansion. Powdered zinc borate has been included to prevent rot, fungal growth,
and insect-caused deterioriation. A prefinished resin-saturated paper embossed with a pronounced wood
grain is thermal-fused to the wood substrate, and a proprietary sealant treatment is applied to ends and
edges. The siding is prefinished with an all-acrylic primer. Fascia and trim products are also available.

TECHNIQUES,  MATERIALS,  TOOLS


1. REPLACE DAMAGED OR DETERIORATED SIDING WITH NEW L-P SMART LAP™
SIDING.
Depending on the most cost-effective approach, engineered wood lap siding can be installed directly to
studs with a weather barrier (Fig. 1); directly to nailable sheathing; over “fan-fold” insulating sheathing;
or to furring strips over masonry or irregular surfaces (siding should not come in contact with masonry).
If a rainscreen/drainage channel behind the siding is desired the siding can be installed over vertical fur-
ring strips at a maximum spacing of 24 inches o.c. Sections of existing Inner-Seal™ OSB siding that have
swelled, edge cracked, or otherwise deteriorated, can be cut out and replaced with new sections of L-P
engineered wood siding, which will closely match the appearance of the old OSB siding. For complete
instructions refer to Application Instructions for Smart Panel™ and Smart Lap™ Siding.
ADVANTAGES: Lightweight, strong, easily worked with conventional tools; appearance of textured painted
cedar siding; joints at trim similar to wood bevel siding; lays flat. Dimensionally stable; will not warp or
cup; free from knot holes; resistant to end-checking and splitting, shrinkage, and buckling. Twenty-five-
year prorated limited warranty against fungal degradation, and cracking, peeling, separating, chipping,
flaking,  or  rupturing  of  the  resin-impregnated  surface  overlay.  Environmentally  sound;  made  from  a
renewable resource. 
DISADVANTAGES: Requires repainting and recaulking over time. New product with limited performance
history. Combustible material. Currently not available in smooth patterns. 

63
FIGURE 1, 2 SMART LAP SMART PANEL

2.  REPLACE  DAMAGED  OR  DETERIORATED  SIDING  WITH  NEW  L-P  SMART
PANEL™ AND EZ PANEL™ ENGINEERED WOOD PANELS.
Available in a variety of thicknesses and patterns simulating vertically grooved plywood siding (Fig. 2). Panels
have shiplapped edges and may be used directly over studs, over structural or nonstructural sheathing, over
existing sound wood siding, and on furring strips over masonry and uneven walls. Panels should not contact
masonry surfaces and vertically grooved panels should not be applied horizontally. Nails must be stain and
corrosion resistant and have a minimum  1/4 inch head. Nails driven below the surface must be sealed. All
joints must be caulked with non-hardening paintable sealant with a service life of at least 25 years. Horizontal
trim should not be placed over grooved siding without proper flashing. If flashing is not practicable, space
trim away from siding so that moisture is not trapped between siding and trim. For detailed installation and
painting requirements refer to Application Instructions for Smart Panel™ & EZ Panel™ Siding.
ADVANTAGES: Less costly than plywood. Smart Panel™ can act as a shear wall; does not require sheath­
ing. Comes primed and can be painted any color. Natural looking wood grain texture. Easily handled and
installed with conventional tools. Twenty-five-year prorated limited warranty against fungal degradation,
cracking,  peeling,  separating,  chipping,  flaking,  or  rupturing  of  the  resin-impregnated  surface  overlay.
Comparable five-year warranty on EZ Panel™, which is a utility grade. 
DISADVANTAGES: Engineered panels require regular repainting and recaulking. New product with limited
performance history. Combustible material.

FURTHER  READING
Application Instructions for Smart Panel ™ & Smart Lap™ Siding, Louisiana-Pacific, March 1998.

PRODUCT  INFORMATION
Louisiana-Pacific, 111 SW Fifth Avenue, Portland, OR 97204; 800–648–6893; www.LPcorp.com (Smart
Lap™, Smart Panel™, and EZ Panel™ siding).

64
13 P LY W O O D   P A N E L
SIDING
ESSENTIAL  KNOWLEDGE
Plywood  panel  siding  has  been  a  popular  material,  especially  in  the  Northwest,  North  Central,  and
Northeastern states, since the early 1950s. Its use has declined in the last decade, however. Further mar­
ket erosion is expected in the next decade as other siding products, such as vinyl siding and fiber cement,
continue to increase in popularity.
As a material, plywood panel siding has changed very little in terms of specifications or product
configuration, except that a variety of special veneer facings is now available that increases paintability and
extends the life of the siding. Some of these products include Simpson Forest Products’ Guardian™ sid­
ing  made  with  a  medium  density  overlaid  resin-impregnated  craft  paper;  Roseburg  Forest  Products’
Breckenridge Siding™ made with “okoume” hardwood surface overlay imported from New Zealand; and
Stimson Lumber Company’s Duratemp™ made with a hardboard surface overlay. As an alternative to spe­
cial surface overlays, many manufacturers offer preprimed plywood siding, although the great majority of
siding is still sold as unprimed.

TECHNIQUES,  MATERIALS,  TOOLS


1. REPAIR EXISTING PLYWOOD SIDING.
Sections of damaged or deteriorated plywood panels can be cut out and repaired with conventional car­
pentry tools if there is sheathing below, but the most typical repair would be to replace the individual panel.
ADVANTAGES: Most economical repair. 
DISADVANTAGES: Repair of individual panels is often not practical, especially if panel is fastened directly
to structure. 

2. REPLACE EXISTING SIDING WITH NEW PLYWOOD PANEL SIDING.
Made from Douglas fir or (increasingly) Southern pine veneers, plywood siding is available in 4 by 8, 4
by 9, and 4 by 10 panels in varying thicknesses, including 11/32,  15/32, and  19/32 inches. Panels are avail-
able smooth faced or textured, grooved or ungrooved, square or shiplap edged. Siding patterns include
channel-grooved,  brushed,  overlaid,  Texture  1-11,  reverse  board-and-batten,  rough  sawn,  and  kerfed
rough sawn (Fig. 1). Battens can be applied for a board-and-batten appearance. Depending on the depth
of the grooves, the panels are designed to be attached directly to framing members 16 or 24 inches o.c.,
or over existing flat siding, insulating or solid sheathing, or furring strips against masonry or uneven walls.
Plywood siding must be primed and finish painted or stained within 30 days of installation. Unless prop­
erly maintained, the surface ply will degrade due to UV and weathering effects and will become brittle,
cracked, and eroded.
ADVANTAGES: Long history of successful applications. Can be applied directly to studs without sheathing. Can
provide shear resistance. Easily worked and erected with conventional tools. One panel covers a large sur­
face area. Dimensionally stable. Available in a variety of textures and styles. Products with special overlaps
have surfaces that, after painting, will not split, check, or crack. Limited 25-year warranties are available.
DISADVANTAGES: Vertical grooves impart a distinctive, “contemporary” appearance that may not be suit-
able given the existing design of the house to be rehabed. Use is generally confined to Northern regions
65
BRUSHED CHANNEL GROOVE

TEXTURE 1-11 LAP SIDING

SMOOTH OVERLAID T1-11 REVERSE BOARD-AND-BATTEN

KERFED OVERLAID T1-11

FIGURE 1 PLYWOOD PANEL TEXTURES
66

of the U.S. Conventional plywood without overlays requires careful attention to initial painting/staining rec­
ommendations. Combustible. Requires on-going maintenance. 

FURTHER  READING
303 Siding Manufacturing Specifications, APA Engineered Wood Association, March 1997.
Performance Rated Siding, APA Engineered Wood Association, April 1996.
Residential Design and Construction Guide, APA Engineered Wood Association, April 1996.

PRODUCT  INFORMATION
Breckenridge Siding™: Roseburg Forest Products, P.O. Box 1088, Roseburg, OR 97420; 800–859–6998.
Champion International Corporation, One Champion Plaza, Stamford, CT 06921; 800–874–3240.
Duratemp Plywood Siding™: Stimson Lumber Company, 520 Southwest Yamhill, Suite 325, Portland, OR
97204; 800–445–9758.
Georgia–Pacific Corporation, P.O. Box 105605, Atlanta, GA 30348–5605; 800–284–5347.
Guardian Siding™: Simpson Timber Company, Third and Frankline, Shelton, WA 98584; 800–782–9378.
Louisiana–Pacific, 111 Southwest Fifth Avenue, Portland, OR 97204; 800–231–1292.
U.S. Forest Industries, Inc., P.O. Box 820, Medford, OR 97501; 800–541–6906.

67
14 F I B E R - C E M E N T
SIDING
ESSENTIAL KNOWLEDGE
Fiber-cement siding, in its present form, is a relative newcomer to the U.S. homebuilding market, having
been introduced in the late 1980s. Asbestos-cement siding, an earlier incarnation of the material, had
been used extensively in the U.S., as well as in Europe, throughout the 20th century. The use of asbestos
in the U.S. was discontinued in the 1970s. Currently fiber-cement siding products are composed of
Portland cement, sand, clay (in some products), and specially treated wood. Today’s products are thicker,
less brittle, and easier to cut and work with than asbestos materials. They are also available in a wider
variety of products such as backer board, lap siding, panel siding, trim, soffits, and fascias.
Fiber-cement siding has generated a great deal of interest among builders and homeowners
because of its strength and impact, rot, and fire resistance. Expectations are that the use of fiber-cement
products and the development of new product types, such as fiber-cement shingle siding, will increase dra­
matically in the next several years.
Fiber-cement siding can be cut and drilled with conventional wood-working tools (although
some installers use diamond-tipped masonry blades for cutting) or scored with special shearing tools and
broken much like paper-faced drywall. Fiber-cement panels are available either preprimed or unpainted,
depending on the individual manufacturer. Paint adheres very well to the material’s slightly textured and
porous surface. The material itself is not affected by intermittent wetting, but it will discolor and stain
unless painted.

TECHNIQUES, MATERIALS, TOOLS


1. REPAIR EXISTING FIBER-CEMENT SIDING.
Dented, cracked, or otherwise distressed siding can be repaired with the use of a latex-modified cemen­
titious patching compound available from fiber-cement manufacturers or from specialty product manu­
facturers (see Product Information). Damaged sections can be cut out with hand or power saws and new
sections installed as necessary. Joints between new and old materials should be primed and caulked.
ADVANTAGES: Can be repaired in much the same manner as solid wood siding.
DISADVANTAGES: Some of the wood grain and stucco patterns have changed somewhat. Adjoining new and
old sections may not match exactly.

2. REPLACE EXISTING SIDING WITH FIBER-CEMENT LAP SIDING.


Fiber-cement lap siding is typically available in a variety of textures, widths from 6 to 12 inches, lengths up
to 12 feet, and in thicknesses between 5/16 and 7/16 inches (Fig. 1). It can be installed directly to studs with
a suitable weather barrier such as housewrap or building paper, or over solid or insulating sheathing, exist­
ing solid wood siding, or furring strips applied to uneven walls or existing masonry surfaces. Fiber-cement
lap siding can be used with conventional wood, fiber-cement, hardboard, or vinyl trim. Lap siding is fastened
by means of stainless or galvanized steel nails, or by means of screws with corrosion-resistant coatings.
Staples are not recommended. Refer to individual manufacturer’s installation manuals for specific recom­
mendations.
ADVANTAGES: Smooth lap siding is close to wood in appearance when painted. Performs well in high-
humidity environments; will not rot; termite resistant; non-combustible; good impact resistance; can be
68
SMOOTH FINISH

TEXTURED

SMOOTH BEADED LAP

TEXTURED BEADED LAP

COLONIAL SMOOTH

COLONIAL ROUGHSAWN

FIGURE 1 LAP SIDING TEXTURES

painted or stained. Up to 50-year limited product warranty against manufacturing defects.


DISADVANTAGES: Wood grain is somewhat more pronounced than rough-sawn cedar. Surface texture can
be distracting in appearance at joints where grain does not align. Requires periodic painting and caulk­
ing, although requires less frequent painting than wood. Variety of siding patterns is less than with other
69

SMOOTH FINISH

STUCCO FINISH

CEDAR TEXTURE WITH 5/8- INCH GROOVES, 8- INCH ON-CENTER

CEDAR TEXTURE WITH MOLDED GROOVES AT 4- INCH INTERVALS

FIGURE 2
PANEL SIDING TEXTURES

siding materials. Heavier than wood. Cutting of material with saws produces silica dust. Brittleness of
material results in significant wear on tools.

3. REPLACE EXISTING SIDING WITH FIBER-CEMENT PANEL SIDING.

Fiber-cement panels are typically 4 by 8, 4 by 9, and 4 by 10, and typically in 5/16-inch thickness. A variety

of textures is available, depending on the manufacturer (Fig. 2). Installed vertically to studs directly, the

panels can act as shear wall bracing. They can also be installed over solid sheathing, existing flush solid

wood siding, or over furring strips against masonry or uneven walls. If required by code, a weather bar­

rier must be installed. Corrosion-resistant nails or screws may be used. Staples are not recommended.

Joints should fall on structural framing members and are typically caulked or covered with a batten strip.

Horizontal joints are flashed with metal Z flashing.

70

Horizontal joints are flashed with metal Z flashing. 
ADVANTAGES: Installs quickly, covering a large area; performs well in high-humidity environments. Can
provide  shear  bracing.  Termite  resistant,  noncombustible,  good  impact  resistance.  Can  be  painted  or
stained; up to 50-year limited product warranty against manufacturing defects.
DISADVANTAGES: Textures do not accurately reflect materials they simulate. Heavier and more brittle than
most siding materials. Material requires special tools to cut and install; requires periodic painting and
caulking. Cutting of material with saws produces silica dust. Variety of panel patterns and textures is less
than other types of panel materials.

FURTHER  READING
“On Site with Fiber-Cement Siding,” David Frane, Journal of Light Construction, January 1998.

PRODUCT  INFORMATION
FIBER-CEMENT MANUFACTURERS
ABTco., 10115 Kincey Ave., Suite 150, Hunterville, NC 28075; 800–566–2282; www.abtco.com (lap and
panel siding).
FCP™, Inc. (successor sales arm of Eternit, Inc.), Excelsior Industrial Park, P.O. Box 99, Blandon, PA
19510-0099;  888–327–0723  (Cemplank™ smooth,  rough-sawn,  and  wood  grain  lap  siding;
Cempanel™ smooth, stucco, and wood grain vertical siding panel).
James  Hardie  Building  Products,  Inc.,  26300  La  Alameda,  Suite  250,  Mission  Viejo,  CA  92691;
800–9–HARDIE;  www.jameshardie.com  (Hardiplank™ smooth,  rough  sawn,  and  wood  grain  lap  siding;
Hardipanel™ smooth,  stucco,  wood  grain  vertical  siding  panels;  Shingleside™  fiber-cement  shingle;
Hardisoffit™, Harditrim™). 
Maxitile,  Inc.,  17141  S.  Kingview  Ave.,  Larson,  CA  90746;  800–338–8453  (MaxiPlank™  smooth  and
wood grain lap siding; MaxiPanel™ smooth, wood grain, V-groove, stucco panels; MaxiTrim™). 
Temple-Inland  Forest  Products  Corp.,  Inc.,  P.O.  Drawer  N,  303  Temple  Dr.,  Diboll,  TX  75941;
800–231–6060.

CUTTING TOOLS
Pacific International Tool & Shear, P.O. Box 1604, Kingston, WA 98346; 800–297–7487. 

PATCHING PRODUCTS
Macklanberg Duncan™, 4041 North Santa Fe, Olkahoma City, OK 73118; 800–654–8454.

VINYL TRIM AND VENT ACCESSORIES
Tamlyn and Sons, 10406 Cash Road, Houston, TX 77477; 800–334–1676.

71
15 E I F S   &   S T U C C O
15.1 EXTERIOR INSULATION AND
FINISH SYSTEMS
ESSENTIAL  KNOWLEDGE
Developed in Europe in the 1950s, and introduced into the U.S. by Dryvit Systems, Inc. in the early 1970s,
exterior insulation and finish systems (EIFS), which are sometimes called synthetic stucco systems, have
largely replaced conventional three-coat Portland cements stucco systems. The industry’s association, the
EIFS Industry Members Association (EIMA) estimates that EIFS currently account for about   3.5 percent
of the residential wall market in the U.S.
The system’s attributes include the benefits of insulation outside the structure (a significant ther-
mal break advantage); reduced air infiltration due to the monolithic nature of the finished membrane; and
great design flexibility. While many of the thousands of buildings clad with EIFS have had few, if any, prob-
lems, poor EIFS performance has been documented on individual projects on an ongoing basis, particularly
in climates with severe temperature swings and high moisture levels. Most recently, attention has focused on
large-scale repairs to houses in Wilmington, N.C., following the discovery that moisture had entered the EIFS
barrier cladding systems through the juncture between EIFS and windows or doors, at deck terminations, at
roof/wall connections, and at window sills. In the absence of drainageways, moisture trapped behind the EIFS
cladding caused deterioration of the substrate. The adverse publicity and class-action lawsuits that followed
have led to a curtailment in the use of barrier EIFS systems in some states, although not nationally. 
Concern about the use of EIFS among the public, the insurance industry, building officials, and
manufacturers  has  also  led  to  the  development  and  promotion  of  new  EIFS  products  that  incorporate
drainageways and moisture barrier membranes behind the insulation boards that allow infiltrating water
to drain out (Fig. 1). The EIFS industry remains fragmented (EIMA represents only 8 of the 30 to 40 EIFS
manufacturers, although its members produce an estimated 85 to 90 percent of the systems sold) and EIFS
installation  systems  and  details  vary  among  manufacturers.  However,  American  Society  for  Testing
Materials (ASTM) has developed recommended installation details and specifications that are part of a
new  ASTM  standard  (ASTM  C1397)  for  barrier  type  systems.  Water  managed  systems  have  yet  to  be
addressed by ASTM. EIMA is working with the National Association of Home Builders (NAHB) Research
Center to develop a third-party applicator certification program.

72 FIGURE 1 GROOVED INSULATION BOARD DRAINAGE LATH/MAT


TECHNIQUES,  MATERIALS,  TOOLS
There are two major classifications of EIFS: barrier systems (which depend on the integrity of the EIFS sur­
face, flashing, and sealants to prevent entry of water), and drainage systems (which employ a variety of
drainage techniques to allow moisture, that may have entered, to exit the system).

1. REPAIR EXISTING EIFS.
The repair of small damaged areas of EIFS, where the substrate is sound, is relatively simple. The affected
area is cut out and the system is rebuilt in much the same way as it was originally installed. If the damage
was caused by water infiltration from deficient flashing, the flashing should be repaired or replaced before
corrective work begins. If the sealant has failed it should be removed and replaced or covered with caulk­
ing products designed for this remedial work. Dow Corning, among other manufacturers, has developed
a variety of restoration recommendations and remedial products, including a preformed silicone extrusion
(Dow Corning 123 silicone seal – Fig. 2) that is designed to span failed sealant joints and weatherseals at
the perimeter of windows and other wall penetrations (see Further Reading). If the deterioration due to
faulty installation or water entry is extensive, the EIFS may have to be removed in its entirety and, in some
cases, the sheathing, trim, windows, and structure as well.
ADVANTAGES: Repairs are simple and work well on small damaged areas where significant water pene­
tration and substrate deterioration has not occurred.
DISADVANTAGES: Serious water entry problems can require extensive removal and rebuilding work. Repaired
areas will probably not match the color of adjacent existing areas and may require a new color coat.

2. INSTALL AN EIFS BARRIER SYSTEM.
Barrier systems have been the basic industry standard until recently, and EIMA and many manufacturers
maintain that when properly detailed and installed they will perform satisfactorily. Some manufacturers,
however, disagree. U.S. Gypsum offers only draining, water-managed systems and Senergy, Inc. will not
authorize the installation of barrier systems on wood frame construction (all manufacturers agree that
barrier systems work over masonry block or concrete substrates that are relatively unaffected by mois-

FIGURE 2 SILICONE SEAL

ture). EIFS typically consist of insulation board made of polystyrene (usually expanded) or polyisocyanu­
rate foam, which is secured to the exterior wall surface (usually DensGlass Gold®, plywood, OSB, or fiber-
cement board) with a specially formulated adhesive or with mechanical fasteners. The foam provides insu­
lation and allows the coating to flex during temperature swings. Some manufacturers provide EIFS without
73
the insulation for installation over masonry or directly to sheathing when insulation is not required (Fig.
3). A water-resistant base coat is applied to the top of the insulation and reinforced with glass-fiber mesh
for added strength. A final coat, typically acrylic, similar to a thickened acrylic paint with a fine aggregate,
is applied as the finish surface. Some manufacturers provide elastomeric coatings, which are softer and
more flexible than the coatings typically used.
ADVANTAGES: More effective than (although often used in conjunction with) comparable between-the-
studs insulation, especially over metal studs. Provides an important thermal break. Reduces air infiltration
(EIMA  claims  up  to  a  55  percent  reduction  over  standard  masonry  or  wood  construction).  Provides
attractive exteriors and design flexibility through a wide variety of colors and textures. Can be fashioned
into  a  variety  of  shapes  and  sizes  to  produce  decorative  details  such  as  cornices,  quoins,  keystones,
arches, columns, reveals, shadow lines, special moldings, etc. Relatively easy to clean and repair small
areas.
DISADVANTAGES: Proper detailing and choice of an experienced applicator is critical. Some manufacturers
have significantly less experience than others and have more limited technical support staff. Some manufac­
turers have model code research reports, others do not. Many residential contractors do not have the skills
and experience of commercial applicators. The specification control and inspection, typical with commer­
cial work, is frequently absent on residential projects. Warranties vary considerably and should be studied
and compared carefully. Insurance and code agencies may not allow barrier systems without certification by
design  professionals  as  to  their  proper  detailing.  Some  states,  such  as  North  Carolina,  and  model  codes
(UBC) do not allow the use of barrier systems with wood-frame construction. The use of barrier systems
should be carefully monitored on a case-by-case basis, as the codes are changing. Extreme heat, dryness,
cold  (especially  freeze-thaw),  and  moisture  conditions  affect  the  system’s  performance.  Proper  flashing,
high-performance sealants, and weather barriers are essential to good performance, but sealants should not
be relied upon in the absence of other weather barriers. Requires careful selection of windows and flashing
detailing to assure wall integrity is not compromised by water weeping into the wall cavity at sill and sill/jamb
interface. Termites and carpenter ants can tunnel into foam plastic and use it as a habitat.

3. INSTALL AN EIFS MOISTURE DRAINAGE SYSTEM. 

Moisture drainage systems, also called water-managed or rain-screen systems, have been used in com­

mercial applications since the early 1990s, and are currently becoming the system of choice for housing

among architects, designers, builders, and code officials. They are similar to barrier systems except that

FIGURE 3 EIFS WITHOUT INSULATION

they employ a drainageway behind the insulation either in the form of vertical grooves cut in the insula­
tion  board,  vertical  furring  strips,  or  a  woven  fabric  drainage  mat  or  other  drainage  system  (Fig.  1).
Proper flashings, weather barriers, and sealant details remain critical as water should still be kept out of
the system. EIFS systems should stop well above grade to restrict insect access and allow for inspection.
ADVANTAGES: All the advantages of barrier EIFS with the additional protection of drainageways to evacuate
74
moisture from the system. Perceived by most builders, architects, and designers as an improved system.
Recommended or required by increasing numbers of insurance companies and code agencies. 
DISADVANTAGES: Generally require mechanical fastening of the foam insulation board, which is more labor
intensive than adhesive applications. Require more attention and cost for secondary weather barriers and
accessories. Require careful attention to system details, including housewrap overlaps to avoid the channel­
ing of moisture behind these weather barriers, particularly at windows, doors, and other openings. Termites
and carpenter ants can tunnel into foam plastic backing and use it as a habitat. There has been limited test­
ing and performance data on the various drainage systems employed. Some building researchers and experts
remain unconvinced that this system solves all the performance problems with barrier systems.

FURTHER  READING
EIFS  Design  Handbook,  CMD  Associates,  1800  Westlake  Avenue  North,  Suite  203,  Seattle,  WA  98109;
206–285–6811; www.eifs.com/aboutcmd.htm.
EIFS New Construction Inspection Manual, CMD Associates, 1800 Westlake Avenue North, Suite 203,
Seattle, WA 98109; 206–285–6811; www.eifs.com/aboutcmd.htm.
EIFS Restoration Guide, Dow Corning #62-510B096; 517–496–6000.
“EIFS Wall Weathers 75-mph Wet Spray Test with No Sealers,” Energy Design Update, October 1998, pp.
10-12.
“Housewraps vs. Felt,” Paul Fisette, Journal of Light Construction, November 1998.
Installation  Checklist,  Exterior  Insulation  Manufacturer’s  Association  (EIMA),  3000  Corporate  Center
Drive, Suite 270, Morrow, GA 30260; 800–294–3462; www.eifsfacts.com.
“Installing Water-Managed Synthetic Stucco,” Russ Minkovich, Journal of Light Construction, September
1998.
“Sill Sentry Designed to Treat Leaking Windows,” Energy Design Update, June 1998, pp. 12-13.
“Synthetic Stucco,” Steven Culpepper, Fine Homebuilding, October/November 1996.

PRODUCT  INFORMATION
EIFS Industry Members Association (EIMA), 3000 Corporate Center Drive, Suite 270, Morrow, GA 30260;
800–294–3462; www.eifsfacts.com.
Dow Corning Corporation, Midland, Michigan 48686–0994; 517–496–6000; www.dowcorning.com.
Dryvit Energy Systems, Inc., One Energy Way, P.O. Box 1014, West Warwick, RI 02893; 800–556–7752;
www.dryvit.com.
Finestone (Simplex Products Div.), 1149 Treat Street, Adrian, MI 49221–0010; 517–263–8881.
Omega Products Corp., P.O. Box 1889, Orange, CA 92668; 714–935–0900; www.omega-products.com.
Parex, Inc., P.O. Box 189, Redan, GA 30074; 800–537–2739; www.parex.com.
Pleko Systems International, Inc., P.O. Box 98360, Tacoma, WA 98498; 206–472–9637; www.pleko.com.
Retro Tek, 4987 County Highway North, Sun Prairie, WI 53590; 800–225–9001.
Senergy Division of HSC, 10245 Centurion Parkway North, Jacksonville, FL 32256; 904–996–6000.
Stuc-o-Flex International, Inc., 17639 Northeast 67th Court, Redmond, WA 98052; 800–305–1045.
TEC Incorporated, 315 South Hicks Road, Palatine, IL 60067; 847–358–9500.
75
Universal Polymers, Inc., 319 North Main Street, Springfield, MO 65804; 800–752–5403.
US Gypsum Company, 125 South Franklin Street, Chicago, IL 60606; 800–USG–4YOU; www.usg.com.
W.R. Bonsal Co., 8201 Arrowridge Blvd., Charlotte, NC 28273; 800–334–0784; www.bonsal.com.

15.2 STUCCO
ESSENTIAL  KNOWLEDGE
Portland cement stucco is a traditional finish material that has been in use in North America for over 300
years. Currently installed as a three-coat system (scratch, brown, and color coat) it is sometimes abbre­
viated to a two-coat system, particularly over masonry.

TECHNIQUES,  MATERIALS,  TOOLS


1. PATCH EXISTING STUCCO.
Hairline cracks are very difficult to patch without making the repair more noticeable than the defect. Some
installers recommend “dusting” with stucco. Cracks between  1/8 to  1/4 inch can be repaired by scraping
out the topcoats to expose scratch coat. An acrylic bonding agent can be used to help bond the repair
coats. On even larger cracks or holes, a self-adhesive fiberglass mesh can be used to strengthen the repair.
Some large holes will require the repair of the building paper behind the wire mesh. For recoloring old
stucco a “fog” coat of cement, color pigment, and lime, but no sand, is sometimes used. Acrylic additives
increase ease of application and cover. Elastomeric coatings can also be used to seal and  recolor  old
stucco.
ADVANTAGES: Stucco repair is relatively easy and cost-effective.
DISADVANTAGES: If large areas are affected, removal may be more practical.

2. INSTALL A STUCCO EXTERIOR WALL FINISH.
Stucco is installed in the Northeastern and North Central states over gypsum sheathing using dimple or
expanded metal diamond lath that holds the plaster away from the sheathing allowing for better cement
bond, expansion and contraction with temperature changes, and for the creation of a drainageway. Over
masonry substrates, stucco is typically applied directly to the substrate without lath. In hotter climates in
the South and Southwest, stucco is often installed over paper-backed lath without sheathing material. This
requires  adequate  bracing  of  the  walls  to  prevent  shear  cracks.  Stucco  can  be  colored  and  scored  to
appear like brick, stone, and other materials.
ADVANTAGES: A proven material that stands up well to moisture in cold climates; can have integral color
or can be coated with elastomeric coatings. Can have a variety of finishes. Easily repaired.
DISADVANTAGES: Requires experienced applicators. Requires fogging to prevent excessive fast curing and
hairline cracking. Integral color can fade, especially if a dark color is chosen. Can be stained at grade by
rain-splattered earth. Requires reinforcement at all openings and periodic expansion joints. Stucco is a
poor insulator.

FURTHER  READING
Oriental Stucco, U.S. Gypsum Co., P682, April 1993.
Portland Cement Plaster Stucco Manual, Portland Cement Association, No. EB049, 1996.
“Patching Stucco,” Ron Webber,  Journal of Light Construction, September 1997.
76
16 E X T E R I O R   T R I M
ESSENTIAL  KNOWLEDGE
Trim has always been an important element in the appearance of houses, as well as a key weather and
waterproofing component. As a finishing element around doors, windows, porches, roof edges, at cor­
ners, and at other building features, trim provides a decorative element and scale. There is a wide variety
of material available for use as trim other than traditional solid wood, such as laminated wood lumber,
engineered wood, wood/thermoplastic composites, fiber cement, and polymers. These new materials have
the appearance of wood trim but promise longer service life. The major threats to trim are ultraviolet radi­
ation, water damage, snow and ice, mold, rot, and insect infestation (all except ultraviolet (UV) related to
moisture). Materials should be selected, detailed, and installed to limit the effects of exposure.

TECHNIQUES,  MATERIALS,  TOOLS


1. REPAIR EXISTING WOOD TRIM WITH EPOXY FILLER.
The decision whether to repair or replace the existing trim will depend on its condition, and whether the
building  is  historically  significant  (if  so,  follow  the  U.S.  National  Park  Services’  Guidelines  for
Rehabilitating  Historic  Buildings referenced  in  Further  Reading).  Before  repair  or  replacement,  the
conditions that caused damage to the trim should be corrected, if possible, and the decision to repair or
replace can then be addressed. Most wood, even if it is seriously decayed, can be reconstituted by means
of liquid epoxy consolidants that impregnate the wood fibers and harden into a mass that can be sawn,
planed, drilled, nailed, sanded, glued, and painted. Most of these epoxy materials have weatherability as
good as or better than wood, and work well at sills, thresholds, and other parts of the building that can-
not  be  easily  replaced.  Epoxy  putties  are  also  available  that  work  in  conjunction  with  liquid  epoxy  to
rebuild missing sections of decorative features and trim (Fig. 1). 
ADVANTAGES: Restoration  of  damaged  trim  material  may  be  less  disruptive  and  less  expensive  than
replacement. Helps maintain historical integrity of trim. 
DISADVANTAGES: Requires careful application. May not be cost-effective for average rehabilitation project.
May not be practicable if deterioration is extensive.

FIGURE 1 USE OF EPOXY PUTTY TO REBUILD TRIM

2. INSTALL NEW TRIM.
If a building’s trim has deteriorated to the extent that it is unsightly or does not function as intended, and
if epoxy consolidation is not cost-effective, the trim and any deteriorated substrate should be removed and
replaced. If deterioration was caused by a lack of flashing (especially window or door heads), sealants or
77
poor detailing, those deficiencies should be corrected or the condition will be repeated. The choice of
trim material has expanded considerably beyond that of solid wood. Trim options include:

■ SOLID WOOD:
For trim and fascias, solid wood is still the favorite material in many parts of the country due to its ease
of application and general availability. Wood species include white and (to a lesser extent) southern yellow
pine, imported pine species, and locally available fir including Douglas fir and Hem-fir. Heartwood grades
of Western red cedar and redwood are more expensive, but considered more dimensionally stable and
resistant to decay because of their natural extractives. Cedar often comes rough-sawn. Redwood is avail-
able in wide boards and is often used for fascias. Clear, vertical grain, all-heart wood material takes paint
better, is more stable, and lasts longer than other grades. Finger-jointed trim is increasingly used and is
available in larger sizes because it is comprised of glued sections of material. Back priming of all solid
wood trim is recommended to protect it from moisture and to keep it from warping. Finished sides are
best protected with two coats of paint or stain.

■ LAMINATED VENEER LUMBER (LVL): 
At least one company, South Coast Lumber, makes LVL trim products. Its ClearLam™ product is made of
Douglas fir core veneers and older face veneers glued together with phenolic adhesives and sprayed with
a preservative to protect the trim in the field. The face is overlaid with a phenolic-based medium density
overlay (MDO) sheet that eliminates face checking and serves as an excellent substrate for paint. All edges
are fully coated with an elastomeric edge coating and primer. Easy to cut, nail, and install, ClearLam™
can be used for fascia, corner boards, and window and door trim, dimensionally stable without knots,
checks, or cracks. 

■ ENGINEERED WOOD TRIM
Engineered trim is a composite of wood fibers and resins. It resembles hardwood, but has added waxes,
resins, and oils to give it better weather resistance. Engineered wood can be used for corner boards, fas­
cias, rake boards, soffits, and door and window trim. A relatively inexpensive, uniform, consistent product,
smoother and straighter than regular wood. 

■ WOOD/THERMOPLASTIC TRIM
Wood/thermoplastic trim is a relatively new composite product made from thermoplastic resins and wood
fiber. This material is exceptionally durable and is becoming popular for exterior decking applications and
as window sills and door jambs. Several companies make limited sizes of flat stock for trim and extruded
brickmold. 

■ FIBER-CEMENT TRIM 
Fiber-cement trim is available from manufacturers of fiber-cement siding products and is generally used in
conjunction with those materials, although it need not be. Used as fascias, rake boards, corner boards, soffits,
and window and door trim. Available in smooth and wood grain finishes, primed or unprimed. This material
takes paint well and is available with a 50-year warranty against warping, cracking, and delamination.

■ POLYMER TRIM
Polymer trim, made from high density polyurethane, is cost effective in replicating the appearance of heav­
ily decorative trim elements such as columns, railings, balusters, brackets, trellises, pediments, shutters, etc. 

FURTHER  READING
“Alternatives  to  Solid  Wood  Exterior  Trim,”  Paul  Fisette,  Building  Materials  and  Wood  Technology
Program, University of Massachusetts at Amherst, www.umass.edu/bmatwt/index.html.

78
The  Secretary  of  the  Interior’s  Standards  for  Rehabilitation  and  Guidelines  for  Rehabilitating
Historic Buildings, Washington: US Dept. of the Interior, National Park Service Preservation Assistance
Division, 1990.

PRODUCT  INFORMATION
RESTORATION PRODUCTS
Abatron, Inc., 5501 95th Avenue, Kenosha, WI 53144; 800–445–1754.
Conservation Services, 8 Lakeside Trail, Kinnelon, NJ 07045; 973–838–6412.
Gougeon Bros., Inc., P.O. Box 908, Bay City, MI 48707; 517–684–7286.
Preservation Resource Group, P.O. Box 1768, Rockville, MD 20849–1768; 301–309–2222; www.prginc.com.
LAMINATED VENEER LUMBER
South Coast Lumber Co., 815 Railroad Ave., P.O. Box 670, Brookings, OR 97415; 541–469–4177.

ENGINEERED WOOD
SmartTrim™,  Louisiana–Pacific  Corp.,  1  East  First  Street,  Duluth,  MN  55802;  800–648–6893;
www.lpcorp.com.
Prime Trim™, Georgia Pacific Corp., 133 Peachtree Street, NE, Atlanta, GA 30303; 404–652–4000.
Trim Craft™, Temple Inland Forest Products, P.O. Box N, Biboll, TX 75941; 800–231–6060; www.tem­
ple.com/tpgl.html.
Protrim™,  ABT  Co.,  10115  Kencei  Avenue,  Suite  150,  Halessville,  NC  28078;  800–927–3146;
www.altco.com/trim.htm.
Forestrim™, Forestex, P.O. Box 68, Forest Grove, OR 97116; 503– 357–2131.
American Hardboard Association, 520 North Hicks Rd., Palatine, IL 60067; 312–934–8800.

WOOD/THERMOPLASTIC COMPOSITE
Durawood PE, The Eaglebrook Companies, 2600 West Roosevelt Rd., Chicago, IL 60608; 312–491–2500.
FrameSaver™, BMS, P.O. Box 631247, 1124 Bennet Clark Rd., Nacogdoches, TX 75963; 409–569–8211.
Crane Plastics Co., P.O. Box 1047, Columbus, OH 43216; 800–366–8472.

FIBER CEMENT
Cem-Trim™, FLP Inc., Excelsior Industrial Park, P.O. Box 99, Blandon, PA 19510–0099; 888–327–0723;
www.flpinc.com.
Harditrim™, James Hardie Building Products, 26300 Los Alameda, Suite 250, Mission Viejo, CA 92691;
888–J–HARDIE; www.jameshardie.com.
Maxitrim™, Maxitile, Inc., 17141 South Kingview Avenue, Lason, CA 90746; 310–217–0316; www.maxitile.com.
Temple Inland Forest Products, P.O. Box N, Biboll, TX 75941; 800–231–6060; www.temple.com.

POLYMER
Fypon, 22 West Pennsylvania Avenue, Stewartstown, PA 17363; 800–537–5349.
Outwater Plaster Industries, P.O. Box 347, Woodridge, NJ 07075; 800–835–4400; www.outwater.com.
Style-Mark, Inc., 960 West Barre Road, Archibold, OH 43502; 800–446–3040; www.style-mark.com. 79
17 S E A L A N T S   &
CAULKS
ESSENTIAL  KNOWLEDGE
Sealants and caulks are the first line of defense, serving as a barrier to both water and air infiltration.
However, not all joints are meant to be caulked; some provide an exit for air or moisture trapped within
the wall assembly. In low-rise residential structures sealants and (to a lesser extent) caulks are used as
elements of a weather barrier system that includes the exterior finish material, drainage planes (building
paper or housewrap), ice and weathershield membranes, and flashing. Sealants and caulks are typically
used at expansion joints, joints between dissimilar materials, joints at window and door openings, at the
juncture of siding and trim, and at flashing. Several factors should be considered in order to achieve sat­
isfactory performance of both sealants and caulks.

■ Material Selection: Materials must have the proper physical characteristics for the specific application,
including elasticity (the ability of a sealant to return to its original profile), elongation (the ability of a
sealant  to  stretch,  as  expressed  as  a  positive  or  negative  percentage),  adhesion  (bonding  between  the
sealant  and  adjacent  materials),  durability,  paintability,  and  compatibility  with  substrate  and  adjacent
materials.

■ Weatherability:  Sealants  vary  with  respect  to  weathering  characteristics.  Indications  of  weathering
include hardening of the material, chalking or discoloration, alligatoring, wrinkling, bubbling, sagging,
erosion, or softening of the sealant surface. Sealants and caulks showing these characteristics should be
replaced.

■ Joint Design: Sealant manufacturers recommend that sealants should adhere to only two surfaces by
use of polyethylene backer rods or bond breaker tape. Three-surface adhesion will lead to cohesive fail­
ure (tearing). Narrow (less than 3/8 inch) or excessively deep sealant joints, that exceed a depth to width
ratio of 1 to 2, may not allow for the proper compression, elongation, or adhesion of sealants. Small joints
prove to be the most difficult to seal because the smallest movement can represent a significant percent-
age  of  expansion.  Interior  applications  typically  do  not  require  nearly  the  same  degree  of  elongation
because the temperature is maintained within a narrow range.

■ Installation: The leading cause of sealant failure is improper installation, elements of which include
improper priming or cleaning of the substrate; installation over incompatible coatings, materials, or con­
taminants (including existing sealants and lubricants); installation during periods of excessive  cold  or
heat, rain, or dampness. Such failures are prime reasons for replacement of sealants and caulks in rehab
work.

The distinction between caulk and sealant, terms often used interchangeably, is essentially the
ability to conform to movement. Caulk typically provides for less movement but is easier to work and is
used for interior applications, while a sealant is used for exterior purposes. Caulking usually refers to latex
sealing compounds that meet ASTM C 834 Standard Specification for Latex Sealing Compounds while
sealants  usually  refer  to  ASTM  C  920  Standard  Specifications  for  Elastomeric  Joint  Compounds.
80
Manufacturers’ instructions and technical assistance should be closely followed. The selection of caulk
should be guided by knowledge of the materials that are to be adhered and the material properties that
are most critical, such as elongation, durability or ease of installation. 
Sealants  are  continuously  evolving  with  new  formulations  for  lower  cost,  ease  of  installation,
adherence, flexibility, and durability. Newer formulations have allowed greater range of uses, but no one
product is ideal in all these respects. It is estimated that there are over 300 sealant manufacturers. Some
make their own sealants while others sell sealants manufactured by others under their “private label.”
Among the most common types are:

■ Latex  and  oil-based  sealants,  generally  referred  to  as  caulks  with  low  flexibility  and  relatively  poor
durability, are low cost and easy to work, suitable for interior applications not exposed to prolonged mois­
ture.

■ Acrylic latex, sometimes referred to as rubberized latex, is a more durable and elastic variation suit-
able for interior and exterior applications. Small amounts of silicone emulsions are frequently added to
enhance performance somewhat.

■ Butyl rubber is commonly employed in insulated window assemblies and between layers of metal flash­
ings because of its good adhesion qualities, ability to resist water and temperature extremes, and because
it remains tacky. It has only moderate flexibility and is difficult to install. 

■ Kraton, a primer-less, solvent-based, synthetic rubber that has become popular as a general purpose
sealant that adheres to most common substrates. Because it is solvent-based, it may shrink slightly.

■ Silicone, used extensively in curtain wall, exterior insulation and finish systems (EIFS), and glazing
applications. It is the most elastic and durable sealant, but not generally paintable. It is difficult to remove,
and not suitable for porous materials in some formulations. Minimal shrinkage.

■ Polyurethanes have excellent movement and durability characteristics, but the flexibility degrades over
time, particularly in direct sunlight, and they are difficult to apply and clean-up.

TABLE 1 TYPES OF CAULKING MATERIALS

BASE TYPE RETAIL $ EST. LIFE USES CLEAN UP


(per 10 oz) (years)

Oil 1-2 1-3 Most dry surfaces* paint thinner


Polyvinyl acetate 1.50-2 1-3 Indoor surfaces only* water
Styrene rubber 2-2.50 3-10 Most dry surfaces* paint thinner
Butyl 2.50-3 4-10 Masonry and metal** paint thinner
Acrylic latex 2-4 5-20+ Most dry surfaces* water
Kraton 5-7.50 10-15 Most dry surfaces* paint thinner
Polyurethane 4.50-10 15-20+ Masonry** acetone, MEK
Silicone 4-7 20+ Glass, Aluminum* paint thinner,
(not for masonry) naphtha, toluene

* wood, drywall, aluminum; e.g., gaps in wood frames around perimeter of house, plumbing penetrations,
gaps in rough openings around windows and doors, boots around supply and return HVAC grills, seal
between bottom plates and subfloor.
** gaps in masonry construction.
81
All sealants require surface preparation and appropriate primers as directed by the manufac-
turer. Sealants are only able to provide for movement in two directions; if the sealant contacts a third sur-
face it will detach from the surface with the least adhesion. Sealants typically are applied with half the width
adhered to either side of the opening in an hour glass shape (Fig. 1). The width of the opening is exposed
on one side and must be prevented from adhering to materials along its other side with a non-adhering
surface referred to as a bond breaker or backer material. The bond breaker material also serves to shape
and support the profile of the sealant and as a secondary barrier.

BAND-AID JOINTS

BUTT JOINTS

FILLET JOINTS

FIGURE 1 JOINT TYPES

TECHNIQUES,  MATERIALS,  TOOLS


1. PREPARE SURFACE, REMOVE EXISTING SEALANTS
All surfaces must be sound, clean, dry, and free of frost, dirt, oil release agents, loose particles, efflorescence,
old sealants, and other foreign substances that impair adhesion bond.  On impervious surfaces, such as glass,
metals, or paints, sealant manufacturers may recommend a commercial grade solvent cleaner such as Xyol,
toluene, or alcohol, or may produce one themselves. For porous surfaces such as cement board, concrete,
concrete block, old brick, and stone, joints can be cleaned by cutting, scraping, sandblasting, saw cutting,
or grinding. Remaining loose dust and particles should be removed by dusting with a stiff non-metallic brush,
vacuuming, or blowing with oil-free compressed air.   Some sealants require a primer prior to application,
some do not. Follow manufacturers recommendations.
ADVANTAGES: Proper preparation will help ensure maximum life of sealant performance.
DISADVANTAGES: Removing contaminants and old sealants, especially silicones, is time consuming and
expensive.

2. INSTALL SEALANT.
Proper installation of sealant is absolutely critical to performance. The methods of preparation and instal-
lation vary among manufacturers and it is best to consult their literature for instructions. Sealants are
available in essentially four types: preformed, tube, cartridge, bulk. Typically, the easier the installation
82
method, the lower the anticipated performance. For this reason materials available in tubes tend to be
water  soluble  caulk  materials  suitable  for  interior  repairs.  Materials  designed  for  exterior  purposes,
specifically windows and doors, require higher performing materials and larger quantities. These materi­
als generally require some form of mechanical means of applying the sealant. The traditional hand-oper­
ated gun provides a relatively simple device with convenient cartridges. Larger bulk-loading guns are also
available to provide for economy in the packaging of materials or when two-part sealants are to be com­
bined on site. Applications of large amounts of sealant are ideally suited for power-assisted equipment.
Traditionally  this  was  pneumatically  driven,  requiring  an  air  compressor.  New  equipment  developed
specifically for this purpose is either electrically or battery driven. With the requirements of application
being so specific, these power tools and preformed materials provide for consistency of application.
ADVANTAGES: New automated tools and new materials provide for greater ease of installation and perfor­
mance than ever before. The wide variety of materials is suitable for virtually any condition.
DISADVANTAGES: The improper selection of sealants has the potential of damaging or discoloring adjacent
materials. 

FURTHER  READING
“Caulking,”  Al  Brendenberg,  Today’s  Homeowner,  www.todayshomeowner.com/todayarticles/paint/­
04.97.62.html.
“Caulking About the Weather,” Josh Garskof, Old-House Journal, November/December 1996.
“Caulks and Sealants,” Fine Homebuilding, Bruce Greenlaw, June/July 1990.
“Premature Sealant Failure,” The Construction Specifier, David H. Nicastro and Joseph P. Solinski, April 1997.
“Silicone Caulking Basics,” Brian Zavitz, Fine Homebuilding, August/September 1997.

PRODUCT  INFORMATION
AC Products, 172 East La Jolla Street, Placentia, CA 94870; 800–238–4204.
AEG, 3 Shaw’s Cove, P.O. Box 6003, New London, CT 06320–1777.
ChemRex/PL Adhesives & Sealants, 889 Valley Park Drive, Shakopee, MN, 55379; 800–433–9517.
DAP, 2400 Boston Street, Suite 200, Baltimore, MD 21224; 800–543–3840; www.dap.com.
Dow Corning Corporation, Midland, MI 48606–0994; 517–496–6000; www.dowcorning.com.
Franklin  International,  Construction  Adhesives  and  Sealants,  2020  Brooks  St.,  Colombus,  OH  43207;
800–877–4583; www.franklini.com.
GE Silicones, 260 Hudson River Road, Waterford, NY 12188; 800–255–8886; www.ge.com.
Insta-Foam Products, Inc., 1500 Cedarwood Drive, Joliet, IL 60435; 800–800–3626.
Macco Adhesives, 925 Euclid Avenue, Cleveland, OH 44115; 800–634–0015; www.liguidnails.com.
Macklanburg-Duncan, 4041 North Santa Fe, Oklahoma City, OK 73118; 800–654–8454; www.macdunc.com.
Miracle Adhesives, TAC Intl, Air Station Industrial Park, Rockland, MA 02370; 800–503–6991.
NPC Sealants, 1208 South Eigth Avenue, P.O. 645, Maywood, IL 60153; 800–654–1042.
OSI Sealants, 7405 Production Drive, Mentor, OH, 44060; 800–321–3578; www.osisealants.com.
Polytite, 324 Ridge Avenue, Cambridge, MA 02140; 800–776–0930; www.polytite.com.
Red Devil, 2400 Vaux Hall Road, Union, NJ 07083; 800–4–A–DEVIL; www.reddevil.com.
Resource Conservation Technology, 2633 North Calvert Street, Baltimore, MD 21218; 410–366–1146. 83
18 P A I N T   &   O T H E R
FINISHES
ESSENTIAL  KNOWLEDGE
Paints, stains, and other coatings protect wood from the deteriorating effects of moisture and ultraviolet
radiation. Areas exposed to the greatest amount of sun and wind-driven rain deteriorate the fastest—typ­
ically the south and west exposures, and the higher portions of the building.
The performance of paints and stains on wood and wood-based composite products (plywood,
oriented strand board, laminated beams, etc.) is affected by the wide range of properties between and
within wood species. Understanding the physical characteristics of various wood species contributes to
appropriate paint and stain selection. Varying properties affecting the performance of finishes include:

■ Density: High density woods (southern pine, Douglas fir, oak) tend to swell, cup, and check more than
low density, “light” woods (redwood, cypress, western red cedar) causing stresses in film coatings that
can lead to cracking and flaking. 

■ Grain characteristics: Vertical grain woods (western red cedar, redwood) have excellent paint-holding
characteristics  because  of  their  narrow  bands.  Flat  grained  woods  (southern  pine,  Douglas  fir)  have
dense, wide bands and hold paint less well, especially if smooth finished.

■ Texture: Some hardwoods (oak, ash) have large pores that cause pin holes to form in the finish. Other
hardwoods (yellow poplar, magnolia, and cottonwood) have smaller pores and good paintability. Paint
and  penetrating  stains  will  last  longer  on  rough-sawn  lumber  and  plywood  than  on  smooth  surfaces
because, in order to achieve the proper coverage, the paint buildup is necessrily greater. Smooth surfaces
of some species, including western red cedar, may exhibit a condition known as “mill glaze” created dur­
ing the planing or drying process. This condition can inhibit the adherance of solid body stains.

■ Knots, extractives, and other irregularities: Knots absorb finish differently than the surrounding wood.
Pitch (resin), oils, and other extractives can leach out of wood and cause staining. Better grades of wood
have fewer defects and are preferable for painting.

■ Growth ring orientation: Flat-grained, softwood lumber (typically used in most grades) shrinks and
swells to a greater extent than vertical-grained lumber. Edge-grained softwoods (available at a premium
price) cup less and hold paint better than flat-grained wood of the same species (Fig. 1).

Most  residential  paints  and  stains  are  classified  as  oil  or  alkyd-based  or  latex-based  (which
includes acrylic). Oil or alkyd-based paints contain inorganic pigments suspended in a natural oil such as
linseed, or synthetic resin (alkyd), and usually a solvent such as mineral spirits (paint thinner), toluene,
or xylol (all petroleum distillates). These paints cure by reacting with oxygen to form a polymeric film.
Latex paints contain inorganic pigments, petroleum-based solvents, and various latex resins, but the sol-
vent is mostly water. The curing of both paints releases volatile organic compounds (VOCs) but the amount
is much less in latex paints (7 to 9 percent, compared to as much as 50 percent for alkyds). New paints
on the market release very low or no VOCs.
84
Modern exterior latex paints, especially the all-acrylic, are generally considered to perform bet-
ter than oil or alkyd-based coatings. Even though alkyd paints provide a more permeable barrier to mois-
ture, acrylic paints are faster drying, more elastic, hold color better, tend not to crack as much, and are
easier to work with and clean up. In general, latex paints and solid-color stains can be applied over either
oil or latex-based finishes. Oil-based coatings should only be applied over oil-based finishes and not latex
products.   Better quality paints contain a greater amount of pigment by weight, cover better, last longer,
and are more cost-effective than lower-quality paints. 

FIGURE 1 GROWTH RING/GRAIN ORIENTATION

TECHNIQUES,  MATERIALS,  TOOLS


1. MAINTAIN EXISTING COATED SURFACES.
Painted, stained, or treated surfaces must be protected from UV radiation, rain, dirt, and mold and mildew
to perform properly. Roof overhangs can help, however, soffits and sidewalls under wide overhangs will
still collect dirt and water-soluable salts (which can interfere with the adhesion of new paints). Dirt, salts,
and  chalk  (individual  pigment  particle  from  weathered  paint)  can  be  removed  by  scrubbing  with 
non-metallic bristle brushes and water. For stubborn stains, a non-ammoniated detergent can be added.
Mold and mildew can be removed by scrubbing with a mixture of one or two parts of bleach to a gallon
of  water.  Surfaces  should  be  rinsed  thoroughly  with  clean  water  prior  to  refinishing.  All  landscaping
should be protected.
ADVANTAGES: Cost-effective, will increase service life of coatings.
DISADVANTAGES: Surfaces will eventually need refinishing.

2. PREPARE PREVIOUSLY COATED SURFACES.
Film-forming paints and solid color stains can fail by cracking, flaking or peeling. Such failures are typi-
cally caused by moisture penetration, painting over weathered wood, prolonged weathering, too much
time between application of primer and top coat applications, and chalked, mildewed, or dirty surfaces that
were insufficiently cleaned prior to coating. Blistering, another common failure mode, can be caused by
high temperature or moisture. Temperature blisters are caused by rapid increases in temperature soon
after painting or by poor quality paint. Moisture blisters can occur anytime excessive moisture penetrates
the surface edges, or back side of the painted material. The source of the moisture should be eliminated
prior to refinishing. Deteriorated coatings can be removed by scrubbing, scraping, sanding, heat, chemical

85
strippers, or pressure washing. Scrubbing is discussed in paragraph 1 above; scraping is best done with
long handled professional scrapers; sanding is best done with orbital or siding sanders equipped with
tungsten carbide abrasive disks (less likely to clog than conventional sandpaper); electrically heated paint
removers can be used to soften and strip oil- or alkyd-based paints; chemical strippers such as lye and
trisodium phosphate (TSP) contain caustic solutions and should be used with care. Naturalizing and sand-
ing is essential. Refer to chemical manufacturers’s recommendations and directions. Wet sand blasting
and high-pressure water sprays are also used, but sand blasting can easily erode and destroy materials.
Pressure washing can be effective for large areas, but should also be used carefully as it can also damage
material. Dry sandblasting should never be used as it is too destructive. Paint can be removed with an
open-flame blowtorch, but this should be left to professionals as the danger from fire is constant and lead
paint can give off noxious fumes. National (Occupational Safety and Health Administration (OSHA) and
HUD), state, and local health departments should be contacted for recommendations and requirements
affecting the removal of lead paint (for houses built or painted prior to 1978).
ADVANTAGES: Proper preparation will make painting easier and enhance the coating performance. 
DISADVANTAGES: Time-consuming and expensive.

3. APPLY PAINT TO NEW OR EXISTING WOOD OR WOOD-BASED COMPOSITE
MATERIALS.
To achieve maximum paint life on new wood, the U.S. Forest Products Laboratory recommends that new
wood be initially treated with a paintable water repellant preservative (especially at openings such as win-
dows and doors where water can collect on horizontal surfaces such as sills, and at lap, butt, and end
joints of siding where the edge grain is exposed). On existing painted surfaces, sanding is particularly
important in order to feather the edges of the existing paint to allow for uniform coverage where new and
old coatings abut. If the existing paint is not feathered, the new paint will fail first (Fig. 2). High-quality
stain-blocking acrylic latex primers are recommended. Alkyd or oil-based primers are recommended for
woods with water-soluble extractives such as redwood and western red cedar, and are still preferred by
many professional painters for new wood. Raw wood should be primed within a few weeks of installation
as a longer delay can cause loss of adhesion. Two coats of good-quality all-acrylic house paint over the
primer are recommended, especially on south and west exposures. A one-coat acrylic house paint over a
properly applied primer should last four to five years; two coats can last twice as long. As with all remedial
work, the various product manufacturers’ recommendations for paint selection, surface preparation, and
paint application should be followed. Most paint failures occur when recommendations are not followed.

EVEN COVER

FEATHERED EDGE

THIN COVER

NON-FEATHERED EDGE

PEELING

PAINT FAILURE AT
NON-FEATHERED EDGE

86 FIGURE 2 FEATHERED EDGES
ADVANTAGES: Paint protects materials from weathering and deterioration due to the effect of rain and sun,
and can dramatically alter the appearance of a house. Has the highest percentage of solids of conventional
wood finishes, and can conceal surface defects and discolorations. New formulations of VOC-free paints
are odorless, fast drying, and can be applied at lower temperatures than conventional latex paints, and
adhere well, including over alkyd paints. 
DISADVANTAGES: Paint is not a preservative and will not protect a substrate from decay if moisture pene­
trates the surface or is absorbed from behind. Will fail if applied incorrectly or without proper prepara­
tions. Not recommended for horizontal exposed surfaces such as wood decking, as water can get behind
paint film and lead to decay. Requires periodic maintenance and repainting. Some new formulations dry
so quickly that it is sometimes difficult to keep a wet paint edge. Alkyd paints are not recommended for
use directly on masonry or other alkaline surfaces except over an alkali-resisting primer or sealer, not; or
over a un-primed galvanized metal surface. Too frequent refinishing, especially with oil-based paints and
solid-color stains, can lead to a thick coating buildup and subsequent cracking and peeling.

4. APPLY OIL-BASED PENETRATING STAINS TO NEW OR EXISTING WOOD OR
WOOD-BASED MATERIAL.
Oil-based penetrating stains use linseed oil or alkyd formulas to seal and protect the wood substrate. Stains
typically contain fungicides, water repellants, UV blockers, and other additives. These stains are available in
varying degrees of pigment densities, from virtually clear and semi-transparent formulations designed to reveal
and enhance the grain, to increasingly opaque coatings including semisolid and solid stains that hide the grain,
but allow the substrate texture to be expressed. The greater the amount of pigment, the greater the hiding
power and UV protection. Solid color stains are usually applied over primers, transparent stains are not. 
ADVANTAGES:  Time  proven,  popular  coatings  that  protect  and  enhance  the  appearance  of  substrates.
Resists blistering, cracking, and peeling better than paints (especially the more transparent formulations).
Can be applied over a wide variety of new solid sidings, including shingles, shakes, plywoods, and trim.
Can be used over some previously stained wood of an equal or less dense pigment formulation. 
DISADVANTAGES:  Not  recommended  for  use  over  oriented  strand  board  (OSB),  cementitious  or  hard-
board products (especially those with medium density overlay surfaces). May not penetrate and may cause
unwanted  gloss  and  blotchiness  when  used  over  existing  unweathered  penetrating  stains.  Not  recom­
mended for decking unless specially formulated for that use. Transparent and semi-transparent finishes
require more frequent reapplication than more solid stains, especially for smooth-faced woods.

5.  APPLY  SOLID  COLOR  ACRYLIC  STAINS  TO  NEW  OR  EXISTING  WOOD  OR
WOOD-BASED MATERIAL.
The paint industry’s interest in developing water-based low-VOC emitting stains has led a number of man­

ufacturers to develop newly formulated, all-acrylic stains for siding products. These flat stains are not pen­

etrating stains, but form protective films. They are thinner coatings than acrylic paints and are designed

to resist cracking, blistering, and peeling while retaining the texture of the substrate materials. Used with

primers, these stains are more flexible and have better color retention than oil-based stains. They can be

used over previously treated oil-based penetrating stains, trim, and a variety of other materials, including

primed metal, cured masonry, plywood, medium density overlaid plywood and hardboard, cementitious

siding, and stucco.

ADVANTAGES: Protects and provides strong color accents to substrate materials. Less likely to peel than

paints.

DISADVANTAGES: Not as long-lasting or easily cleaned as all-acrylic paints.

6. APPLY SPECIALTY COATINGS. 

Many specialty coatings are available that compliment paint and stain products, including:

■ Paints designed specifically for masonry.

■ Tinted and untinted bleaching oils that contain oxides to accelerate the weathering process.

■ Slightly tinted, clear, oil-based finishes that retard the normal gray weathering of wood and impart a

slight reddish-brown tint.
87

■ Wood cleaners that are formulated to remove mildew, mold, algae, and dirt using chemicals such as
sodium hydroxide.
■ Wood “brighteners” that are formulated to remove tanniss bleed in extractive-prone woods, such as
cedar and redwood. 
ADVANTAGES: Unique and potentially useful products for special needs.
DISADVANTAGES: Difficult to anticipate the results of these products without careful research and inspec­
tion of their use on existing buildings, or examination of samples. 

FURTHER  READING
“Finishes for Exterior Wood—Selection, Application, and Maintenance,” U.S. Department of Agriculture,
Forest Service, Forest Products Laboratory, Forest Products Society, Madison, WI, 608–231–2152.
“Latex Enamel Problems and Solutions,” James Berney, Dan Greenough, and Doug Kelly, Journal of Light
Construction, January 1997.
“The Art of Painting,” Brad Lemley, This Old House, June 1998.

88
APPENDIX
PROFESSIONAL  ASSOCIATIONS  &  RESEARCH  CENTERS
ADHESIVE AND SEALANT COUNCIL AMERICAN WOOD COUNCIL
1627 K Street, NW, Suite 1000 P.O. Box 5364
Washington, DC 20006-1707 Madison, WI  53705–5364
202–452–1500 800–890–7732
www.ascouncil.org www.awc.org

AMERICAN FIBERBOARD ASSOCIATION AMERICAN WOOD PRESERVERS ASSOCIATION
AMERICAN HARDBOARD ASSOCIATION P.O. Box 286
1210 West Northwest Highway Woodstock, MD 21163–0286
Palatine, IL 60067
847–934–8800 AMERICAN WOOD PRESERVERS INSTITUTE
1945 Old Gallows Road, Suite 150
AMERICAN FOREST & PAPER ASSOCIATION Vienna, VA 22182
111 19th Street, NW, Suite 800 703–893–4005
Washington, DC  20036
202–463–2700 APA-THE ENGINEERED WOOD ASSOCIATION
www.afandpa.org P.O. Box 11700
Tacoma, WA 98411–0700
AMERICAN INSTITUTE OF TIMBER 253–565–6600
CONSTRUCTION www.apawood.org
7012 South Revere Parkway
Suite 140 ASSOCIATION OF THE WALL AND CEILING
Englewood, CO 80112 INDUSTRIES
303–792–9559 1600 Cameron Street
www.aitc-glulam.org Alexandria, VA 22314
703–684–2924
AMERICAN NATIONAL STANDARDS INSTITUTE
11 West 42nd Street, 13th Floor BRICK INDUSTRIES ASSOCIATION
New York, NY 10036 11490 Commerce Park Drive
212–642–4900 Reston, VA 20191–1525
www.ansi.org 703–620–0010
www.bia.org
AMERICAN SOCIETY FOR TESTING AND
MATERIALS BUILDING SEISMIC SAFETY COUNCIL
100 Barr Harbor Drive NATIONAL INSTITUTE OF BUILDING SCIENCES
West Conshohocken, PA 19428 1090 Vermont Avenue NW, Suite 700
610–832–9500 Washington, DC 20055
www.astm.org 202-289-7800
[email protected]
AMERICAN SOCIETY OF CIVIL ENGINEERS
1801 Alexander Bell Drive
Reston, VA  20191–4400
800–548–2723
www.asce.org 89
BUILDING STONE INSTITUTE
COPPER DEVELOPMENT ASSOCIATION

P.O. Box 5047


260 Madison Avenue

White Plains, NY 10602–5047


New York, NY 10016

914–232–5725
800–232–3282

www.copper.org

CALIFORNIA REDWOOD ASSOCIATION

405 Enfrente Drive, Suite 200


COUNCIL OF AMERICAN BUILDING OFFICIALS

Novato, CA 94949
5203 Leesburg Pike, Suite 708

888–225–7339
Falls Church, VA 22041

www.calredwood.org
703–931–4533

www.cabo.org

CANADA MORTGAGE AND HOUSING

CORPORATION
THE ENGINEERED WOOD ASSOCIATION

Housing Information Center


7011 South 19th Street

700 Montreal Road


P.O. Box 11700

Ottawa, ON, Canada K1A 0P7


Tacoma, WA 98411

613–748–2367
253–565–6600

www.cmhc-schl.gc.ca
www.apawood.org

CANADIAN CONSTRUCTION MATERIALS


EXPANDED POLYSTYRENE (EPMA)

CENTRE
MOLDERS ASSOCIATION

Institute for Research in Construction


1926 Waukegan Road, Suite 1

National Research Council


Glenview, IL 60025–1770

Montreal Road, Bldg. M-24


800–607–3772

Ottawa, ON, Canada K1A 0R6

613–993–6189
FOREST PRODUCTS LABORATORY

www.nrc.ca/ccmc
US DEPARTMENT OF AGRICULTURE

One Gifford Pinchot Drive

CEDAR SHAKE AND SHINGLE BUREAU


Madison, WI 53705–2398

P.O. Box 1178


608–231–9200

Sumas, WA 98295
www.fpl.fs.fed.us/

604–462–8961

www.cedarbureau.org
GYPSUM ASSOCIATION

810 1st Street, NE, Suite 510

CELLULOSE INSULATION MANUFACTURERS


Washington, DC 20002

ASSOCIATION
202–289–5440

136 South Keowee Street


www.gypsum.org

Dayton, OH 45402

937–222–2462
HARDWOOD PLYWOOD & VENEER

www.cellulose.org
ASSOCIATION

P.O. Box 2789

CONSTRUCTION SPECIFICATIONS INSTITUTE


Reston, VA 20195–0789

601 Madison Street


703–435–2900

90 Alexandria, VA 22314 www.hpva.org

703–684–0300
www.csinet.org
INTERNATIONAL ASSOCIATION OF STONE
THE MASONRY SOCIETY

RESTORATION AND CONSERVATION
2619 Spruce Street, Suite B

30 Eden Alley, Suite 301
Boulder, CO 80302–3808

Columbus, OH 43215
303–939–9700

614–461–5852

NAHB REMODELORS COUNCIL

INTERNATIONAL CONFERENCE OF BUILDING
1201 15th Street, NW

OFFICIALS
Washington, DC 20005

5360 South Workman Mill Road
202–822–0212

Whittier, CA 90601

800–336–1963
NATIONAL ASSOCIATION OF THE

www.icbo.org
REMODELING INDUSTRY

3800 North Fairfax Drive, Suite 2

INTERNATIONAL FIRESTOP COUNCIL
Arlington, VA 22203–1627

25 North Broadway
703–276–7600

Tarrytown, NY 10591
www.ebtech.com

914–332–0040

www.firestop.org
NATIONAL CONCRETE MASONRY ASSOCIATION

2302 Horsepen Road

INTERNATIONAL INSTITUTE FOR LATH AND
Herndon, VA 20171–3499

PLASTER
703–713–1900

820 Transfer Road
www.ncma.org

St. Paul, MN 55114–1406

612–645–0208
NATIONAL FRAME BUILDERS ASSOCIATION 

4840 West 15th Street, Suite 1000

INTERNATIONAL REMODELING
Lawrence, KS 66049–3876

CONTRACTORS ASSOCIATION
800–844–3781

17 South Main Street
www.knight.idir.net

East Granby, CT  06026

800–937–4722
NATIONAL INSTITUTE OF BUILDING SCIENCES

www.remodelingassociation.com
1090 Vermont Avenue, NW, Suite 700

Washington, DC 20005

INTERNATIONAL STAPLE AND TOOL
202–289–7800

ASSOCIATION (ISANTA)
www.nibs.org

435 North Michigan Avenue

Chicago, IL  60611
NATIONAL PAINT AND COATINGS

312–644–0828
ASSOCIATION

1500 Rhode Island Avenue, NW

MASON CONTRACTORS ASSOCIATION OF
Washington, DC 20005

AMERICA
202–462–6272

1910 South Highland Ave., Suite 101
www.paint.org

Lombard, IL 60148

630–705–4200

www.masoncontractors.com
91
NATIONAL PARTICLEBOARD ASSOCIATION
SOUTHERN FOREST PRODUCTS ASSOCIATION

18928 Premiere Court
P.O. Box 641700

Gaithersburg, MD 20879–1569
Kenner, LA 70064–1700

301–670–0604
504–443–4464

www.pbmdf.com
www.sfpa.org

NATIONAL TECHNICAL INFORMATION SERVICE
STRUCTURAL BOARD ASSOCIATION

US DEPARTMENT OF COMMERCE
3413 56th Street, Suite A

5285 Port Royal Road
Gig Harbor, WA 98335

Springfield, VA 22161
253–858–7472

800–553–6847
www.sips.org

www.ntis.gov

STRUCTURAL INSULATED PANEL ASSOCIATION

NORTH AMERICAN INSULATION
1331 H Street, NW, Suite 1000

MANUFACTURERS ASSOCIATION
Washington, DC 20005

44 Canal Center Plaza, Suite 310
202–347–7800

Alexandria, VA 22314 
www.sips.org

703–684–0084

www.naima.org
STUCCO MANUFACTURERS ASSOCIATION

507 Evergreen Road

PAINTING AND DECORATING CONTRACTORS
Pacific Grove, CA 93950

OF AMERICA
408–649–3466

3913 Old Lee Highway., Suite 33B

Fairfax, VA 22030
TIMBER FRAME BUSINESS COUNCIL

800–332–7322
c/o Jerry Rouleau

www.pdca.com
P.O. Box B1161

Hanover, NH  03755

POLYISOCYANURATE INSULATION

MANUFACTURER ASSOCIATION
TRUSS PLATE INSTITUTE

1001 Pennsylvania Avenue, NW, Fifth Floor
583 D’Onofio Drive, Suite 200

Washington, DC  20004
Madison, WI 53719

202–624–2709
608–833–5900

www.pima.org

VINYL SIDING INSTITUTE

PORTLAND CEMENT ASSOCIATION
1801 K Street, Suite 600K

5420 Orchard Road
Washington, DC  20006

Skokie, IL 60087–1083
888–FORVSI–1

847–966–6200
www.vinylsiding.org

www.portcement.org

SEALANT, WATERPROOFING, AND

RESTORATION INSTITUTE

2841 Main

92
Kansas City, MO 64108

816–472–7974

www.swrionline.org

WESTERN RED CEDAR LUMBER ASSOCIATION

1200–555 Burrard Street

Vancouver, BC, Canada V7X 1S7

604–684–0266

www.coti.org/WRCLA

WESTERN WOOD PRODUCTS ASSOCIATION 

522 SW Fifth Avenue, Suite 500

Portland, OR 97204–2122

503–224–3930

www.wwpa.org

WOOD TRUSS COUNCIL OF AMERICA

6425 Normandie Lane

Madison, WI 53719

608–274–4849

www.trusspro.com/wtea/

93

THE REHAB GUIDE
VOLUME ONE: FOUNDATIONS

VOLUME TWO: EXTERIOR WALLS

VOLUME THREE: ROOFS

VOLUME FOUR: WINDOWS AND DOORS

VOLUME FIVE: PARTITIONS, CEILINGS, FLOORS, AND STAIRS

VOLUME SIX: KITCHENS & BATHS

VOLUME SEVEN: ELECTRICAL/ELECTRONICS

VOLUME EIGHT: HVAC/PLUMBING

VOLUME NINE: SITE WORK

U.S. Department of Housing and Urban Development
Washington, DC 20410–6000

Official Business August 1999
Penalty for Private Use, $300 HUD-DU100C000005956