Correct Pump Installation
Correct Pump Installation
Correct and complete installation practices can mean the difference between a pump
that gives many years of trouble-free service and one that requires constant and
repetitive maintenance. While the space available to us in this article denies us the
opportunity to provide a detailed instruction on how to install all types of pumps, most
of the information herein refers to the single-stage, end-suction design.
Three particular areas must be satisfied to ensure that a pump will provide long and
reliable operation within a system.
Foundation
Piping arrangement
Alignment
Fig. 1. Sleeve and “J” type anchor bolts
Foundation
In general, a pump should be mounted on a strong baseplate supported by a strong
concrete foundation. It is also necessary to properly connect the pump to the system
by accurately aligning it to the piping system, as well as the driving motor.
A strong foundation and grouting can result in a unit that gives reliable, uninterrupted
service versus one that requires constant realignment. It should be everyone’s concern
that only the best materials—together with proper design—be used when installing
the pump.
The concrete foundation must be substantial enough to absorb any vibration and form
a permanent rigid support for the baseplate. A frequently used rule of thumb is that the
foundation should be about five times the weight of the pump/motor assembly and
approximately 6″ longer and wider than the baseplate. The anchor bolts are usually of
the sleeve type—or the “J” type—shown in Fig. 1 and must be located in accordance
with the certified outline drawing of the baseplate.
Prior to mounting the baseplate, the entire surface of the foundation should be leveled
by chipping away any defective concrete, leaving it rough, but level. The surface must
then be freed of all oil, grease and loose particles. While individual practices vary
throughout industry, there is a tendency in most leading companies to remove the
pump and driver from the baseplate prior to installation. This facilitates leveling of the
base and in removing any distortion.
The baseplate should be supported on leveling screws, shims or metal wedges with a
small taper located close to the foundation bolts. All leveling screws and other areas
that require protection from grout spatter should then be covered with a wax to
prevent the grout from adhering to them. Check the machined mounting surfaces on
the baseplate by adjusting the leveling devices and using a precision level. Ensure that
the baseplate’s machined mounting surfaces are horizontal, flat and parallel. To
prevent stress and distortion of the equipment, all surfaces in the same plane must be
within 0.002″ overall.
When the baseplate is level, check that all support wedges or shims are in full contact
with the foundation and baseplate. Tighten the foundation anchor bolts evenly and
double-check the level.
The temperature of the baseplate, grout and foundation should be kept between 40 and
90 F during grouting—and for a period of at least 24 hours afterwards. When using
cement-based grouting, follow the grout supplier’s instructions in detail and ensure
that the grout placement is done quickly and continuously to prevent cold joints and
voids under the baseplate. The grout should be allowed to harden in accordance with
the manufacturer’s instructions.
The use of epoxy grout is becoming increasingly common in a number of industries.
The increased bond strength helps to maintain the alignment between the pump and
driver, thereby reducing misalignment failures and maintenance costs. Its use also
facilitates cleanup in the event of an accidental spill as the surface of epoxy grout is
nonporous.
Piping arrangement
Without any doubt, this is the single most abused area of pump installation. In fact, it
can be stated unequivocally that most pumps are piped up incorrectly.
Even today, many installations resemble a “plumber’s nightmare.” In these situations,
the pumps look as though they’ve been squeezed into a corner, out of the way, and the
pipes threaded in and out, without consideration for fluid flow patterns or access for
future maintenance activities. The blame for this must be laid squarely at the feet of
the pump supplier! After all, if you were installing a new pump in a new system,
where would you go for information on how the pump piping should be arranged?
The location of the pump relative to its suction source is critical to its ultimate
reliability. Every pump needs to be located as close to its suction source as possible to
reduce the effect of friction losses on the NPSH available. However, it must also be
far enough away from the suction source to ensure that correct piping practices can be
followed (Fig. 2).
These piping practices involve a number of simple rules which, if followed, will
eliminate a significant percentage of all potential pump problems.
1. Provide the suction side with a straight run of pipe, in a length equivalent to 5 to 10 times
the diameter of that pipe, between the suction reducer and the first obstruction in the line.
Failure to do so can create problems such as hydraulic instabilities in the impeller that
translate into additional shaft loading, higher vibration levels and premature failure of the
seal and bearings.
2. The pipe diameter on both the inlet and the outlet sides of the pump should be at least one
size larger than the nozzle itself. The pipe diameter on the horizontal inlet to the pump
suction must be reduced to the nozzle diameter by means of an eccentric reducer positioned
in such a way as to have the flat side on top. The increaser on the discharge side can be a
standard concentric design.
3. Eliminate elbows mounted on the inlet nozzle of the pump. Failure to do so can cause the
hydraulic instabilities referred to in rule #1 above.
4. Eliminate the potential for vortices or air entrainment in the suction source. These
conditions can cause problems that are frequently confused with cavitation.
5. Arrange the piping in such a way that there is no strain imposed on the pump casing, as
discussed in the following section on alignment.
Alignment
Industry has progressed well beyond any discussion of the statement that good
alignment is essential to safe and trouble-free operation of rotating equipment. When
we discuss “alignment” in the pump industry, we are usually discussing either “piping
alignment” or “shaft alignment.” It must be noted that the term “coupling alignment”
is a misnomer.
Shaft alignment…
We are not concerned about bringing the coupling halves into alignment. The only
criterion is to ensure that the shafts of the pump and its driver will rotate on a common
axis. If the shafts are not coaxial, the resulting moments will increase the forces on the
pump shaft and bearings, causing accelerated wear and premature failure.
In one misaligned condition, the two lines can be parallel with each other, but at a
constant distance apart. This is referred to as offset or parallel misalignment (Fig. 3).
In the other, one line will be at an angle to the other, and is referred to as angular
misalignment.
Parallel misalignment can be considered as the distance between the driver shaft
centerline and the pump shaft centerline at any given point along the length—and this
misalignment can happen in any plane. So, it is worthwhile to take the necessary
measurements on the top and on the bottom for vertical offset and also on each side
for the horizontal offset.
Angular misalignment refers to the difference in slope of the two shafts. If the pump,
base and foundation have been properly installed, the shaft centerline of the pump can
be considered as level and, therefore, as the reference or datum line. The slope of the
driver shaft can be calculated by determining the offset measurement at two different
points, subtracting one from the other, then dividing the result by the axial distance
between the two points. This misalignment needs to be measured and calculated in
both the vertical and horizontal planes.
Shaft couplings…
It is important to mention that flexible shaft couplings are not necessarily the answer
to a shaft misalignment problem. All couplings resist being operated when
misaligned, and the restoring forces and moments resulting in this resistance can
damage bearings, seals and the shaft itself. These restoring forces are proportional to
misalignment. In other words, the larger the misalignment of the shafts, the greater the
forces on the bearings, etc. Thus, the shafts of the pump and the driver should be
aligned as closely as possible to provide optimum reliability of the pump.
Piping misalignment…
Piping flanges must be accurately aligned before the bolts are tightened, and all
piping, valves and associated fittings should be independently supported without any
strain being imposed on the pump. Any stresses imposed on the pump casing by the
piping reduce the probability of satisfactory reliability and performance—and can
result in high maintenance costs.
Laser pipe alignment tools provide significant benefits to the pump user. Mounted on
the pump or the piping, these tools are an effective way to prevent pipe strain during
initial installation, which is exactly the right time to stop it.
The effects of pipe strain in a conventional process pump also can be transmitted to
the shaft coupling. With the accuracy of laser alignment technology, pipe strain can be
measured much in the same way as soft foot and should be integrated into the shaft
alignment program. By loosening the pipe connection after a correct shaft alignment
has been performed, any movement at the coupling will indicate the existence of pipe
strain and can therefore be corrected.
As there is an exception to almost every rule, the API 610 Pump Specification used in
the petroleum industry identifies a maximum level of forces and moments that may be
imposed on the pump flanges. These must be acceptable to any pump being sold into
any industry using that specification. As a consequence, all API pumps are of a much
more robust and heavier design than their ANSI size equivalents.
Conclusion
Improper pump installation can lead to premature failure and increased maintenance
costs. Conversely, when they are correctly installed and given reasonable care and
maintenance, your pumps will be capable of operating satisfactorily—and delivering
for you—for a long time. MT