AMSWMS Code 0740C
AMSWMS Code 0740C
HDS Confidential 1 of 7
The change of contents for Version 0740/C
4) Clearing the port configuration not completed on the change of the interface board
Item Description
Contents When the type of the installed interface board is changed, the port option setting does not clear,
due to a microcode bug in the initialization process.
In changing interface board, the following information should be cleared.
A) Host Group
B) LU Mapping
C) Port Options
Setting of Host Group and LU Mapping are cleared normally, but Port Options are not cleared.
HDS Confidential 2 of 7
5) True Copy Path failure occurred with "command time out"
Item Description
Contents If sequential write to the True Copy P-VOL would be done, the path failure will occur. Due to a
microcode bug in drive writing process, timeout may occur by taking unexpected long time to
access the larger size stripe.
The problem may occur with the following condition on True Copy S-VOL:
A) RAID 6, Stripe size:512KB, Segment size 16KB, 5D+2P and more
B) RAID 6, Stripe size:512KB, Segment size 64KB, 18D+2P and more
C) RAID 6, Stripe size:256KB, Segment size 8KB, 5D+2P and more
D) RAID 6, Stripe size:256KB, Segment size 16KB, 13D+2P and more
E) RAID 6, Stripe size:64KB, Segment size 4KB, 13D+2P and more
F) RAID 5, Stripe size:512KB, Segment size 16KB, 8D+1P and more
G) RAID 5, Stripe size:256KB, Segment size 8KB, 8D+1P and more
9) Auto negotiation failure when FC cable is inserted in the port after removed from the port
Item Description
Contents The port speed may change from 2Gbps to 1Gbps when inserting FC cable in the port after prior
removal from the port, due to a microcode bug in link up logic of auto negotiation, function.
The problem may occur when all the following conditions are met:
A) Direct connection between HOST and DF700
B) Host environment: AIX with FC6228, FC6239 HBA
C) FC cable is inserted again after prior removal
HDS Confidential 3 of 7
10) When Subsystem boots, it does not detect failure in spite of ENC cables connected abnormally
Item Description
Contents When the Subsystem boots it does not detect the failure. The subsystem comes Ready despite
ENC cables being connected abnormally (IN and OUT are reversed). This is due to a microcode
bug in the ENC cable (IN/OUT check) during the Subsystem booting.
11) Subsystem does not come ready with "Unit which cannot be managed (Unit-XX)"
Item Description
Contents Subsystem does not come ready with "Unit which can not be managed (Unit-XX)" in following
order of connection.
RKH (DF700H) – RKA (FC) – RKA (FC) – RKAT (SATA)
Due to a microcode bug in the order of failure detection during the Subsystem booting.
The problem may occur with all the following conditions met.
A) The timing of Subsystem booting
B) DF700H
C) The last additional UNIT is RKAAT (SATA)
D) HDU (HDU-14) which is in RKA(FC) connected next to the basic UNIT
12) Execute pairresync during Quick Format for PVOL after Shadow Image I/O Switch
Item Description
Contents With Shadow Image I/O Switch Mode enabled in Shadow Image, and when the HDD that
compose PVOL are blockaded, the correct maintenance procedure is below. In the state of PSUE
(SVOL Switch), Quick Format for the PVOL is possible. No check of paireresync done for
PVOL executing Quick Format
Maintenance Procedure:
A) Exchange of the obstacle HDD
B) Execute Quick Format for the PVOL
C) Wait for completion of Quick Format
D) Execute pairresync after the (C)
In the case of (C), when pairresync executed before Quick Format is completed, the pairresync
executed incorrectly. As a result, a host may not recognize PVOL.
With all of the following conditions met, the phenomenon may occur:
A) Shadow Image is enabled
B) “Shadow Image I/O Switch Mode” enabled
C) The HDD that composes PVOL are blockaded
D) Execute Quick Format after the obstacle HDD exchange
E) Execute pairresync during Quick Format for the PVOL
HDS Confidential 4 of 7
14) Subsystem down with "Backend down [Cable ERR]"
Item Description
Contents Subsystem down may occur by Loop obstacle during the Subsystem booting. Problem may
occur with all the following conditions met.
A) The timing of Subsystem booting
B) The last of additional UNIT is RKAT(SATA) and connected on Path0 or Path2
C) There is Loop obstacle in CTL#0
HDS Confidential 5 of 7
20) System down during Snapshot restores
Item Description
Contents Restore of Snapshot can be execute by "pairresync -restore" command. System down (both
controllers failure) might occur just before finishing restore of Snapshot. Due to a microcode
bug, the end process of Snapshot restore takes more than 10 seconds in proportion to LU
capacity. DF controller failure may occur for watchdog timeout (10 seconds) at the end process
of Snapshot restore.
With all of the following conditions met, the phenomenon may occur.
A) Snapshot license is available
B) LU size of Snapshot pair is larger than 100GB
C) Executing Snapshot restore (pairresync -restore)
D) No LAN access is during the end process of Snapshot restore
(Neither Management LAN nor Maintenance LAN is accessed)
It is so that the timer of watchdog timeout is cleared by LAN access
25) DF does not respond with raw I/O in NIC connection of RedhatLinux4.0U1
Item Description
Contents ISP4022 firmware bug in Linux raw I/O
The problem may occur with all the following conditions met.
A) ISCSI
B) RAW I/O from Linux
C) High-load I/O from multiple hosts
HDS Confidential 6 of 7
26) CTL reboots, (include online micro program exchange) host connection path does not recover.
Item Description
Contents When self-test program runs at port A, AIX HBA (FC6239) of direct connecting port B of
DF700 hung.
The problem may occur with all the following conditions met.
A) DF700 XS/S + 4G FC I/F
B) Direct connection from AIX+HBA(FC6239) to port B of DF700
C) When the CTL reboots (include online micro program exchange)
HDS Confidential 7 of 7