Chapter 12 - House Drains and House Sewers Checklist
Chapter 12 - House Drains and House Sewers Checklist
Chapter 12 - House Drains and House Sewers Checklist
CHECKLIST
1203. 1 The building sewer, beginning 0.6 meter from outside face of ✔
wall of building or structure, shall be of such materials as approved by
Administrative Authority under the approval procedures set. forth in
Chapter 12 of this Code
1203.2 Jointing methods and materials shall be as prescribed in Chapter ✔
13 of this Code.
CHECKLIST
Authority.
1206.3 No building sewer or other drainage piping or part thereof, ✔
constructed of materials other than those approved for use underground
shall be installed not less than 0.6 meter from the outer face of any
building foundation or wall, nor less than 0.3 meter between the finish
surface of the ground. The provisions of this Subsection include
structures such as porches and steps, whether covered or uncovered,
bree1.eways, roofed '"porte cocheres", roofed patio~, carports, covered
walks, covered driveways, and similar structures or apputenances.
✔
127.1 Cleanouts shall placed inside the- building in car the connection
between the building drain and the building sewer or installed outside the
building at the lower end of the buildi1ig drain and extended to grade.
Two-way clean-out fitting installed at connection point of building drain
and building sewer outside the building nuy be installed in lieu of a single
clean-out. Additional building sewer cleanouts shall be installed not to
exceed 15 meter on center in straight runs and for each aggregate change
in direction exceeding 135 degrees.
1207.2 When a building sewer or a branch thereof does not exceed 3 ✔
meters in length and is a sho!t straight line extension {rom a building
drain which its provided with a cleannout, no cleanout will be required at
its point of connection to the building drain.
1207.3 All required building sewer cleanouts shall be extended to ✔
grade. When building sewer is located under buildings, the cleanout
requirements of Section 1207 shall apply.
1207.4 Each cleanout shall be installed so that it opens to allow ✔
cleaning of horizontal lines in the direction of flow of the soil or
waterline or an right angle thereto, and except in the case of wye branch
and end-of-line cleanout, shall be installed vertically above the flow line
of the pipe.
1207.5 Cleanouts installed under concrete ·or asphault paving shall be ✔
mad~ accessible by strong yard boxes with hinged cover or cxtending the
top cover with countersunk operating nut flush with paving with
approvcd materials and be adequately protected.
1207.6 Approved manholcs may be installed in lieu of cleanouts when
first approved by the Administrative Authority. The maximum distance
between manholes shall not exceed 91 meters.
✔
1210.1 Every abandoned building (house) sewcr thereof, shall be
plugged or capped in an approved manner property line within 1.5m of
the property line.
1210.2 Every cesspool septic tank or seepage pit which has been ✔
abandoned or has been discontinued from further usc ur to which no mere
waste no more soil pipeline from plumbing fixtures arc connected.
1210.3 The top cover or arch over the cesspool, septic tank or seepage ✔
pit shall be removed before ti !ling and the ti !ling shall not extend above
the top of the vertical portion of the sidewalls.
1210.4 No person owning or controlling any cesspool, septic tank or ✔
seepage pit in the premises of such person or in that ponion of any public
street, alley or other public property abutting such premises, shall fail,
refuse or neglect to ~amply from the department having jurisdiction.