0% found this document useful (0 votes)
126 views

Programmable Transmitters

This document summarizes a programmable temperature transmitter that converts temperature sensor signals into a standard 4-20 mA output signal. It can accept input from RTD, resistance, or thermocouple sensors. The transmitter amplifies and converts the sensor signal near the point of measurement to eliminate electrical interference. It transmits the accurate temperature reading over just two wires through distances of thousands of feet. The transmitter is configurable via PC to set the measurement range and other parameters according to the application.

Uploaded by

jose cruz
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views

Programmable Transmitters

This document summarizes a programmable temperature transmitter that converts temperature sensor signals into a standard 4-20 mA output signal. It can accept input from RTD, resistance, or thermocouple sensors. The transmitter amplifies and converts the sensor signal near the point of measurement to eliminate electrical interference. It transmits the accurate temperature reading over just two wires through distances of thousands of feet. The transmitter is configurable via PC to set the measurement range and other parameters according to the application.

Uploaded by

jose cruz
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

TT508/TT518 Programmable

Temperature Transmitter

Overview
This transmitter amplifies a signal from a RTD or linear resist-
ance, and it turns the signal into a current which increases from
4 to 20 milliamperes as the temperature or input signal increas-
es. This industry-standard 4-20mA signal travels thousands of
feet over a pair of wires, ignoring electrical interference and
bringing the temperature, accurately, into your computer or
controller. Drawing power directly from the signal line, only 2
wires are needed for power and signal.
• RTD or Ohm input
• Accurate, Stable 4–20mA Output
• PC and field-programmable Specifications
• FM Approved Intrinsically Safe Ambient temperature range: -40°C to +85°C
Supply voltage: 8 -30 VDC
Converts multiple inputs Warm-up time: 5 min.
Temperature measurement can be done with one of several
Communication interface: PC Interface/Loop Link
RTD’s: 100 Ω, 1000 Ω platinum, 100 Ω Nickel and 1000 Ω
Nickel. Signal/noise ratio: Min. 60 dB

Because amplification and conversion of the input signal is Response time (programmable): 0.33 sec. to 60 sec.
performed within a few feet of the sensor, electrical interfer-
Update time: 135 msec.
ence in noisy environments is eliminated. The transmitter
can be mounted at the field location in a standard DIN form Calibration temperature: 20 to 28°C
B head or on a DIN rail inside a local box.
Effect of supply voltage change: < 0.005% of span/ VDC
EMC-lmmunity influence: < ±0.5% of span
Applications
Vibration: IEC 600 68-2-6 Test FC
• Single temperature measurement
Lloyd's specification no. 1: 4 g / 2 - 100 Hz
2
Max. wire size: AWG14 (1.5 mm )
Configuration
The TT508/TT518 is delivered configured to the customer’s Air humidity: 0 - 95% RH
specifications, including the transmitter’s measurement Dimensions: ∅1.73 x 0.84 in (∅44 x 20.2mm)
range and RTD type.
Tightness (enclosure/terminal): IP 68 / IP00
Weight: 50g
PC Programming
The TT508/TT518 transmitter can be configured via a standard
PC using a programming kit. It can be configured before instal-
lation or while installed in the process - even in hazardous
areas. Communication is 2-way, so set-up and serial/tag
numbers can be retrieved from the transmitter.

= STANDARD OPTIONS
Specifications subject to change

Page 4-8
Inputs (common specifications) Output
Max. offset: 50% of selected max. value The 4-20 mA output follows the TT518 input configuration,
Cable resistance per wire (max.): 10Ω reflecting the temperature and/or resistance. The unit is pro-
tected against polarity reversal. The output signal action can
Sensor current: >0.2mA, <0.4mA be reversed with respect to the input signal. Sensor and/or
Effect of sensor cable resistance: cable errors can be programmed to cause the output to go
(3-wire): < 0.002 Ω/Ω to a fixed value.

Input: Specification and order options:

INSTRUMENTS
Type Minimum Maximum Minimum
Value Value Span
TT518 Model Number:
PD (Pt100) -200°C +850°C 25°C
TT518 Approvals, fits .236” Probe Max
PF (Pt1000) -200°C +850°C 25°C
TT508 No Approvals, fits .250” Probe Max
Linear Res. 0 Ω 10000 Ω 30 Ω
PD Sensor Type:
Basic accuracy: PD = 100 Ω Platinum RTD (0.00385)
PF = 1000 Ω Platinum RTD (0.00385)
PD/PF (Pt100/1000): <±0.3°C
Linear Resistance: <±0.2Ω (-25/200) Ranging:
Specify temperature range in either °C or °F.
Temperature coefficient: For example, -25° to +200°C = 4 to 20 mA.
PD/PF (Pt100/1000): <±0.01°C/°C C Display Units:
Linear Resistance: <±20mΩ/°C C = Celsius
F = Fahrenheit
Current output:
1 Calibration:
Signal range: 4 - 20 mA 1 = Nominal
Min. signal range: 16 mA 2 = Matched to sensor ±0.75% of span
Load resistance : < (Vsup. – 8) / 0.023 [Ω] For other calibration options, contact Minco
Load stability: ± 0.01% of span / 100 Ω Z Sensor Leads: (3 Lead Recommended)
Y = 2-lead RTD (Supplied with jumper wire to
Sensor error detection: connect terminals 3 and 4)
Programmable: 3.5 - 23 mA, or no action Z = 3-lead RTD
Namur NE43 Downscale/Upscale: 3.5 mA/ 23 mA
TT518PD(-25/200)C1Z : Sample part number
Approvals:
Note: TT508 does not carry any external approvals, but
EMC: EN 61326-1
does allow a .250" probe to pass through its center hole
ATEX.: KEMA 03ATEX1535
FM: 2D5A7
CSA: 1125003
GOST R: Yes
GOST Ex: Yes
DNV Marine: Stand. F. Certification No. 2.4

Input
The input type is selected to be one of these types:
• RTD (2 or 3-wire): PT100, PT1000

= STANDARD OPTIONS
Specifications subject to change

Page 4-9
TT509/TT519 Programmable
Temperature Transmitter

Overview
This transmitter amplifies a signal from a thermocouple, and
it turns the signal into a current which increases from 4 to 20
milliamperes as the temperature or input signal increases.
This industry-standard 4-20mA signal travels thousands of
feet over a pair of wires, ignoring electrical interference and
bringing the temperature, accurately, into your computer or
controller. Drawing power directly from the signal line, only
2 wires are needed for power and signal.
• Thermocouple or Voltage Input
• Accurate, Stable 4–20mA Output
• PC and field-programmable
Specifications
• Galvanically Isolated
Ambient temperature range: -40°C to +85°C

Converts multiple inputs Supply voltage: 7.2 -30 VDC

Temperature measurement can be done with multiple thermo- Warm-up time: 5 min.
couple types, which boast high operating temperature ranges. Communication interface: PC Interface/Loop Link
Because amplification and conversion of the input signal is Signal/noise ratio: Min. 60 dB
performed within a few feet of the sensor, electrical interfer-
ence in noisy environments is eliminated. The transmitter can Response time (programmable): 1 sec. to 60 sec.
be mounted at the field location in a standard DIN form B Update time: 440 msec.
head or on a DIN rail inside a local box.
Calibration temperature: 20 to 28°C
Effect of supply voltage change: < 0.005% of span/ VDC
Applications
• Single temperature measurement EMC-lmmunity influence: < ±0.5% of span
Electrical Isolation, test/operation: 1.5kVAC/50VAC

Configuration Vibration: IEC 600 68-2-6 Test FC


The TT509/TT519 is delivered configured to the customer’s Lloyd's specification no. 1: 4 g / 2 - 100 Hz
specifications, including the transmitter’s measurement 2

range and thermocouple type. Max. wire size: AWG14 (1.5 mm )


Air humidity: 0 - 95% RH

PC programming Dimensions: ∅1.73 x 0.84 in (∅44 x 20.2mm)


The TT509/TT519 transmitter can be configured via a standard Tightness (enclosure/terminal): IP 68 / IP00
PC using a programming kit. It can be configured before instal-
Weight: 50g
lation or while installed in the process - even in hazardous
areas. Communication is 2-way, so set-up and serial/tag num-
bers can be retrieved from the transmitter.

= STANDARD OPTIONS
Specifications subject to change

Page 4-10
Inputs (common specifications) Output
Max. offset: 50% of selected max. value The 4-20 mA output follows the TT519 input configuration,
Input: reflecting the temperature. The unit is protected against
Type Minimum Maximum Minimum
polarity reversal. The output signal action can be reversed with
Value Value Span
respect to the input signal. Sensor and/or cable errors can be
E -100°C +1000°C 50°C
J -100°C +1200°C 50°C programmed to cause the output to go to a fixed value.
K -180°C +1372°C 50°C
T -200°C +400°C 50°C
B +400°C +1820°C 100°C Specification and order options:

INSTRUMENTS
N -180°C +1300°C 50°C
R -50°C +1760°C 100°C TT519 Model Number:
S -50°C +1760°C 100°C TT519 Approvals, fits .236” Probe Max
TT509 No Approvals, fits .250” Probe Max
K Sensor Type:
Basic accuracy: E=Type E Thermocouple
TC type E, J, K, L, N, T: <±1°C J=Type J Thermocouple
TC type B, R, S: <±2°C K=Type K Thermocouple
Voltage: ≤±10uV T=Type T Thermocouple
B=Type B Thermocouple
Temperature coefficient: N=Type N Thermocouple
TC type E, J, K, T: <±0.05°C/°C R=Type R Thermocouple
S=Type S Thermocouple
TC type B, N, R, S: <±0.2°C/°C
V = Voltage Input
Voltage: <±1uV/°C
(-25/200) Ranging:
Cold Junction Compensation: <±1°C
Specify temperature range in either °C or °F.
Current output: For example, -25° to +200°C = 4 to 20 mA.
Signal range: 4 - 20 mA C Display Units:
Min. signal range: 16 mA C = Celsius
Load resistance : < (Vsup. – 7.2) / 0.023 [Ω] F = Fahrenheit
MV = Millivolts
Load stability: ± 0.01% of span / 100 Ω
1 Calibration:
Sensor error detection: 1 = Nominal
Programmable: 3.5 - 23 mA, or no action Y Sensor Leads:
Namur NE43 Downscale/Upscale: 3.5 mA/ 23 mA Y = 2-lead
Approvals: TT519K(-25/200)C1Y: Sample part number
EMC: EN 61326-1 Note: TT509 does not carry any external approvals, but
ATEX.: KEMA 06ATEX0062 does allow a .250’” probe to pass through its center hole
GOST R: Yes
GOST Ex: Yes
DNV Marine: Stand. F. Certification No. 2.4

Input
The input type is selected to be one of these types:
• Type E, J, K, T, B, N, R, S Thermocouple
• Voltage Input

= STANDARD OPTIONS
Specifications subject to change

Page 4-11
Programmable Transmitters

Overview
Models TT520 and TT530 are programmable
transmitters designed for process control
and other applications. Both transmitters
use a 4-20mA current loop output and are
PC programmable to accept a signal from a
thermocouple, a Resistance Temperature
TT520
Detector (RTD), or a millivolt signal. Model TT520
can be mounted at the field location in a standard DIN
form B head or on a DIN rail inside a local box (with an AC807
Minco DIN rail adapter), whereas model TT530 can be
mounted vertically or horizontally on a DIN rail.
• T/C, RTD, or mV input TT530

• Accurate, Stable 4-20mA Output


• PC and field-programmable TC Input:

• Galvanically isolated Minimum measurement range:


Type E, J, K, T: 50°C
• FM Approved Intrinsically Safe
Max. offset: 50% of selected max. value
• Single temperature measurement
Basic accuracy:
Type E, J, K, T: <1°C
Cold junction compensation (CJC): <1.0°C
Specifications
Common Specifications: Temperature coefficient:
Type E, J, K, T: <± 0.05 °C / °Camb
Supply voltage: 7.2 - 30 VDC Sensor error detection: yes
Temperature coefficient: < ± 0.01% of span/ °C RTD Minimum Maximum Minimum
type value value span.
Effect of supply voltage change: < 0.005% of span/ VDC PD (Pt100) -200°C +850°C 25°C
Max. wire size: AWG14 (1.5 mm2) PF (Pt1000) -200°C +850°C 25°C

Air humidity: 0 - 95% RH RTD-input:


Basic accuracy PD/PF (Pt100/1000): <±0.2°C
Dimensions:
Temperature coefficient: <±0.01°C / °C
TT520: Ø1.73 x 0.84 in (Ø44 x 20.2mm)
Current output:
TT530: 4.29 x .0.93 x 4.09 in (109 x 23.5 x 104mm)
Signal range: 4 - 20 mA
AC205817 USB Loop Link Programmer: Load resistance: < (Vsup. - 7.2) / 0.023 [Ω ]
TT520 and TT530 transmitters are preconfigured for ease
Intrinsic Safety data: FM Approved Intrinsically Safe for Class 1,
of use. The AC205817 USB Loop Link Programmer allows
Div. 1, Groups A-D, Entity Approval (pending)
the user to reconfigure the transmitter using free, Windows-
based software. Vmax: 30.0 VDC Ci: 1 nF
Imax: 120 mADC Li: 10 μH
Tightness (enclosure/terminal):
Pmax: 0.84 W
TT520: IP 68 / IP00
TT530: IP50 / IP20 Europe: ATEX II 1 G

Weight: Meets these European requirements:


TT520: 50 g EMC 2004/108/EC: Standard EN 61326
TT530: 145 g

= STANDARD OPTIONS
Specifications subject to change

Page 4-16
Specifications and order options Dimensions in inches (mm)
TT520 Model Number: 0.93 (23,5)
TT520 Temperature Transmitter 4.09 (104,0)
TT530 DIN Rail Temperature Transmitter 11 12 13 14

PD Sensor Type:
PD = 100Ω Platinum RTD (0.00385)
PF = 1000Ω Platinum RTD (0.00385)
E = Type E Thermocouple
J = Type J Thermocouple
4.29 (109,0) 3.54 (90,0)
K = Type K Thermocouple
T = Type T Thermocouple
(-25/200) Temperature Range:
Specify temperature range in either °C or °F.

INSTRUMENTS
For example, -25° to +200°C = 4 to 20 mA.
C Temperature Units: 41 42 43 44

C = Celsius
F = Fahrenheit
1 Calibration:
1 = Nominal
Wiring Diagrams
2 = Matched to sensor ±0.75% span
For other calibration options, contact Minco
Y Sensor Leads:
Y = 2-lead RTD (or thermocouple)
Z = 3-lead RTD
X = 4-lead RTD
TT520PD(-25/200)C1Y = Sample part number

Dimensions in inches (mm)

1.30 (33,0)

1 2

0.75
(19,1)

6 3

5 4
0.255
.245 (6,48)
(6,22) DIA.
DIA.
1.74 (44,2)

Specifications subject to change

Page 4-17
Programmable Transmitters w/ HART® Protocol
Communication interface: HART® 7/5 and PC interface

Temperature coefficient: < ± 0.005% of span/ °C

Effect of supply voltage change: < 0.005% of span/ VDC


Max. wire size: AWG14 (1.5 mm2)
Air humidity: 0 - 95% RH
Dimensions:
TT511/TT521 TT511/TT521: Ø1.73 x 0.84 in (Ø44 x 20.2mm)
TT531: 4.29 x .0.93 x 4.09 in (109 x 23.5 x 104mm)
TT531
Overview Tightness (enclosure/terminal):
TT511/TT521: IP 68 / IP00 TT531: IP50 / IP20
Models TT511, TT521 and TT531 are programmable transmit-
ters designed for process control and other applications. All Weight:
three models use HART® communication protocol and are PC TT511/TT521: 50 g TT531: 145 g
programmable to accept a signal from a thermocouple, a
AC205817 USB Loop Link Programmer:
Resistance Temperature Detector (RTD), or a millivolt signal.
TT511/TT521 and TT531 transmitters are preconfigured for
Model TT511/TT521 transmitter can be mounted at the field
ease of use. The AC205817 USB Loop Link Programmer
location in a standard DIN form B head or on a DIN rail inside a
allows the user to reconfigure the transmitter using free,
local box (with an AC807 Minco DIN rail adapter). Model TT531
Windows-based software.
can be mounted vertically or horizontally on a DIN rail.
• T/C, RTD, or mV input
TC Input:
• HART® 7/5 Communication Protocol
Minimum measurement range:
• PC and field-programmable Type E, J, K, T : 50°C
Max. offset: 50% of selected max. value
• Galvanically isolated
Basic accuracy:
• FM Approved Intrinsically Safe
Type E, J, K, T : <±0.5°C
• Single temperature measurement Cold junction compensation (CJC): <±1.0°C
• Difference temperature measurement Temperature coefficient:
Type E, J, K, T: ± 0.025 °C / °Camb
• Average temperature measurement
Sensor error detection: yes
RTD-input:
HART® Communication RTD Minimum Maximum Minimum
By way of 2-wire HART® communication between the process type value value span.
computer and the TT511, TT521 or TT531, the transmitter is PD (Pt100) -200°C +850°C 25°C
programmable, readable, and controllable. PF (Pt1000) -200°C +850°C 25°C
Basic accuracy PD/PF (Pt100/1000): <±0.1°C
• Up to 63 transmitters can be controlled in a multidrop
Temperature coefficient: <±0.005°C / °C
system. (Parallel connection of all transmitters on 2 wires).
Current output:
• Set-up, configuration and control can be done from a central
Signal range: 4 - 20 mA
monitoring room.
Load resistance: < (Vsup. - 8) / 0.023 [Ω]
When each transmitter is connected to a 2-wire cable, a
Intrinsic Safety data: FM Approved Intrinsically Safe for Class 1,
standard 4-20 mA signal can be used at the same time as
Div. 1, Groups A-D, Entity Approval (pending)
the HART® communication.
Vmax: 30.0 VDC Ci: 1 nF
Imax: 120 mADC Li: 10 μH
Specifications Pmax: 0.84 W
Europe: ATEX II 1 G
Common Specifications:
Meets these European requirements:
Supply voltage: 8.0 - 30 VDC
EMC 2004/108/EC: Standard EN 61326-1
Specifications subject to change

Page 4-18
Specifications and order options Wiring Diagrams
TT521 Model Number:
TT511 No Approvals, Temperature
Transmitter with HART® protocol, fits
.250” Probe Max
TT521 Temperature Transmitter with
HART® Protocol, fits .236” Probe Max
TT531 DIN Rail Temperature Transmitter
with HART® Protocol
PD Sensor Type:
PD = 100Ω Platinum RTD (0.00385)
PF = 1000Ω Platinum RTD (0.00385)
E = Type E Thermocouple
J = Type J Thermocouple
K = Type K Thermocouple

INSTRUMENTS
T = Type T Thermocouple
(-25/200) Temperature Range:
Specify temperature range in either °C or °F.
For example, -25° to +200°C = 4 to 20 mA.
C Temperature Units:
C = Celsius
F = Fahrenheit
1 Calibration:
1 = Nominal
2 = Matched to sensor ±0.75% span
For other calibration options, contact Minco
Y Sensor Leads:
Y = 2-lead RTD (or thermocouple)
Z = 3-lead RTD
X = 4-lead RTD
TT521PD(-25/200)C1Y = Sample part number

Dimensions in inches (mm)


1.30 (33,0) 0.75
(19,1)

1 2
HART® Multidrop Wiring Diagram
+ + A TT511 / TT521 / TT531 Transmitters
1.74 (44,2)
Power
supply
6 3

5 4 - B
0.255
0.255(6,48)
(6,48) DIA.
DIA. (TT511)
0.245 (6,22) DIA. (TT521) Rload>250Ω, <1100Ω Max. 63 transmitters
0.93 (23,5)
R
4.09 (104,0) C
11 12 13 14 -

4.29 (109,0) 3.54 (90,0)

= STANDARD OPTIONS
41 42 43 44 Specifications subject to change

Page 4-19