Column Design
Column Design
Column Design
2013. 03.18
SK E&C
INSTRUCTION
2
What’s Column ?
Vessel Tank
Column = Tower Vessel = Drum, Pot Tank
일정이 상압의 유체
상의 압
• Ex. Distillation Tower • Higher than Pressure 15 Psi, Dia • Ex. Storage Tank
력을 가
150mm
진 유체 Product Tank
Fractionation Tower
• Ex. Surge Vessel
Water Tank
Tray Tower
Knock Out Drum
• Except, Ball Tank
Packing Tower • Pot
• Reactor, Vessel
3
Why Tray Tower?
4
Why Tray Tower?
Be Economical
5
Layout(Tray Tower)
6
Layout(Tray Tower)
7
Component(Tray)
Downcomer Area
Active Area
Free Area
Hole Area
8
Component(Tray)
Sieve Valve
9
Performance
Performance Curve
Vapor Velocity
Liquid Velocity
10
Performance
Type Definition
• Condition in a liquid-vapor counterflow device (such as a distillation
Flooding column) in which the rate of vapor rise is such as to prevent liquid downflow,
causing a buildup of the liquid (flooding) within the device.
• Where the droplets, instead of failing out into the downcomer carry up into
Blowing the holes of the tray above.
• Dumping is liquid fall down continually through the hole area due to vapor-
Dumping liquid flow is too small compared to hole area. There is no mass transfer in
dumping situation
11
Performance
12
Performance
System • When the actual capacity more than the design capacity
13
COLUMN DESIGN
INTRODUCTION
COLUMNS / TOWERS
14
COLUMN DESIGN
WORK PROCEDURE
15
COLUMN DESIGN
GENERAL
BASIC PRINCIPLES
16
COLUMN DESIGN
GENERAL
1. Column / Tower
2. Column internals
3. Reboiler
4. Condenser
5. Reflux drum
17
COLUMN DESIGN
18
COLUMN DESIGN
TRAY vs PACKED TOWER
19
COLUMN DESIGN
20
COLUMN DESIGN
21
COLUMN DESIGN
TRAYS
TYPES OF TRAYS
Bubble cap Tray
Sieve Tray
Valve Tray
Dual Flow Tray
Baffle Tray
High Performance Tray(ADV, MD, Ripple, Etc.)
Others(Raindeck,ADE,MU)
Valve Tray
22
COLUMN DESIGN
TRAYS
COMPARISON OF TRAYS
Type Sieve Tray Valve Tray Bubble-cap Tray Dual Flow Tray
Capacity High High to Very High Moderate Very High
Turndown About 2:1 About 4~5:1 Excellent Lower than Sieve Tray
Good at Low Liq.
Main Application Most Columns when Most Columns Low Liquid Highly Fouling Service
turndown is not critical
23
COLUMN DESIGN
TRAYS
TRAY COMPONENTS
Outlet Weir
Tray Deck Tray Deck
Downcomer Downcomer
Recessed Sump
24
COLUMN DESIGN
PACKINGS
TYPES OF PACKINGS
Random Packing
Structured Packing
Grid Packing
25
COLUMN DESIGN
PACKINGS
PACKING COMPONENTS
Distributor / Re-Distributor
Bed Limiter
Packing Support
Collector Tray
26
COLUMN DESIGN
PACKINGS
DISTRIBUTORS
27
COLUMN DESIGN
PACKINGS
BED LIMITER
28
COLUMN DESIGN
PACKINGS
PACKING SUPPORT
COLLECTOR TRAY
29
COLUMN DESIGN
TOWER INTERNALS
TOP SECTION
30
COLUMN DESIGN
TOWER INTERNALS
MIDDLE SECTION
31
COLUMN DESIGN
TOWER INTERNALS
MIDDLE SECTION
32
COLUMN DESIGN
TOWER INTERNALS
BOTTOM SECTION
33
COLUMN DESIGN
TOWER INTERNALS
BOTTOM SECTION
34
COLUMN DESIGN
SIZING
DESIGN CONSIDERATIONS
Operation Pressure
35
COLUMN DESIGN
SIZING
DIAMETER CALCULATION
36
COLUMN DESIGN
SIZING
DIAMETER CALCULATION
37
COLUMN DESIGN
SIZING
DIAMETER CALCULATION
if ADM < 11% AAM, use 11% of AAM or 2xADM, whichever is smaller
38
COLUMN DESIGN
SIZING
HYDRAULICS DESIGN PROCEDURE
c. Outlet Weir Height
A. Design Condition d. Downcomer Clearance Area
a. Determine Vapor-Liquid Load e. Bubbling Area
- Vapor Flow rate f. Free Area
- Liquid Load
b. Determine Physical Property C. Preliminary Performance Checks
- Vapor Density a. Capacity : Determine Safety factors
- Liquid Density - Limiting Capacity
- Liquid Viscosity - % Flooding of Active Area
- Liquid Surface Tension - % Flooding of Downcomer
- Foaming Factor - Pressure Drop
b. Lower Limits
B. Preliminary Estimate of Tower Size - Weeping
a. Assume Tray Spacing - Dumping
b. Compute Approximate Tower Diameter c. Entrainment
c. Compute Minimum Downcomer Area at Top - Vapor rate (ratio of Valve Open)
d. Estimate Downcomer Area at Bottom d. Efficiency
e. Assume one Path Tray
f. Prepare Preliminary Tray Layout D. Adjust design where necessary to obtain satisfactory
safety factors
C. Design Considerations
a. Valve Type Selection and Layout F. Repeat Performance Checks
b. Outlet Weir Length
39
COLUMN DESIGN
TRAY DESIGN OUTPUT
SIEVE TRAY HYDRAULIC RATING SUMMARY PRO BASETRAYTM
DESCRIPTION
I. TRAY GEOMETRY: II. PROCESS LOADINGS: 1 2 3 4 5 6
40
COLUMN DESIGN
SIZING
Dry Pressure Drop : Should not exceed 15% of TS, 10% is conservative
41
COLUMN DESIGN
QUICK GUIDE
TRAY COLUMNS
Min. Dia. For Tray Column : 750 mm(Except for Cartridge Type)
42
COLUMN DESIGN
TRAY DATA SHEET SAMPLE TOWER DATA SHEET SAMPLE
PAGE OF PAGE 2 OF 3
PROJECT NO. PROJECT NO.
PROJECT NAME PROJECT NAME
ITEM NO. Q'TY ITEM NO. Q'TY
TRAY LOADING SERVICE TOWER SERVICE
DOC. NO. REV. DOC. NO. REV.
1 Vessel Number 1 TYPE & DIMENSION
2 Vessel Name or Service 2 VESSEL
3 Operating Case 3 Type:
4 Number of Trays on the Section 4 I.D: mm
5 Quantity of Trays 5 TL-TL: mm
on contained therein are the property of SK Engineering & Const. Co. Ltd (SKEC). They are merely loaned and shall not be disclosed to others or reproduced in any manner without written permission of SKEC.
on contained therein are the property of SK Engineering & Const. Co. Ltd (SKEC). They are merely loaned and shall not be disclosed to others or reproduced in any manner without written permission of SKEC.
6 Type of Tray 6 OPERATING CONDITIONS C V
7 Tow er Internal Diameter, mm 7 Fluid Name
8 Tray Spacing, mm 8 Specific Gravity
9 Number of Passes 9 Pressure kg/cm2G
10 Allow able Pressure Drop per Tray, kg/cm2 10 Temperature ℃ 100
1000
11 Allow able Leakage Thru Tray, kg/h 11 DESIGN CONDITIONS M1
R
12 Tightness Requirements 12 Temp.
100 10
13 13 Int. Press. kg/cm2G @ ℃
5 SPCS@450 = 2250
14 9
14 Ext. Press. @ ℃
15 Condition at Tray No. 15 MDMT ℃ 8
SEE SHT #3
16 Vapor to Tray 16 Postw eld Heat Treatment
7
17 Flow Rate, kg/h 17 Insulation
18 Molecular Weight 18 Fire Proofing 6
19 Temperature, ℃ 19 Type of Head
5
20 Pressure, kg/cm2g 20
700
Compressibility Factor 21 A
21
350
22 CORROSION ALLOWANCE 4
22 Density, kg/m3
3 SPCS@600 = 1800
23 Liquid from Tray 23 Shell mm
9800 T/T
24 Flow Rate, kg/h 24 Heads mm 3
25 Temperature, ℃ 25
26 Density, kg/m3 26 SPECIAL CONDITION 2
27 Viscosity, cP 27
28 Surface Tension, dynes/cm 28 1
29 Operating Range Maximum, % 29 NOZZLE SCHEDULE RR
750
30 Minimum, % 30 Mark Q'ty Size Facing Rating Description
31 Vapor System Factor, FSV 31
32 Liquid System Factor, FSL 32 L1 1300 I.D. D2
4050
L2
34 Turndow n Requirement, % 34
35 Furnish Seal Pan below Bottom Tray ? Yes No 35 L3
250
38 Tray Material : Corrosion Allow ance, mm : 38 L4 D1SO
41 41
3000 SKIRT
VORT EX
42 42
BREAKER
43 43
E
44 44
45 45 8-M56 ANCHOR
BOLT S
46 46
WIT H T YPE II
47 47 SUPPORT 1318 O.D. SKIRT
48 48 LUGS PER
49 49 MATERIAL SPECIFICATIONS BADGER ST D
50 50 Shell / Heads
51 51 Internal
52 52
53 53 NOTE
43
PILOT PROJECT TRAINING – COLUMN DESIGN
END
44