PAGEL-GROUT
V1/50 (0– 5 mm) grout universal-grout for precision machines of any kind
V1/10 (0– 1 mm) grout
turbines, generators, compressors, diesel engines
V1/160 (0–16 mm) grout
and other power equipment operating under heavy
V1/50 combines the characteristics of V1 and vibration
V12
anchor screws, levelling units and sole plates
for grouting height from 20-120 mm
steel and concrete columns
high flowability, also after 2 hours
prefabricated concrete units and structural
cement-based and chloride-free
steelworks
controlled and even expansion with a rigid bond
bridge bearings and construction joints
between concrete foundation and machine base
plate crane rails and radio telescopes
high early and final strength steel and blast-furnace plants as well as mines
low modulus of elasticity in connection with high paper plants, chemical plants and refineries
bending strength
TECHNICAL DATA
Testing temperature: 20 °C
Additive : General Construction Permission Nr. Z-3.21-1461
Corresponding Certificate Nr. 219000
Storage: 12 months in sealed container, dry
Packaging: 25-kg-bag
Hazard class: no dangerous substance, observe safety data sheet
GISCODE: ZP1
100 1,0
90 0,9
80 0,8
70 0,7
60 0,6
50 0,5
40 0,4
30 0,3
20 0,2
10 0,1
1 3 7 28 90 3 6 9 12 18 24
days hours
V1/50 ®
V1/10 ®
V1/160®
®
PAGEL-GROUT
APPLICATION
SURFACE: Clean thoroughly, free of loose and unsound material, remove any cement slurry by means of hydraulic water-
blasting or similar till carrying capacity of grain structure is reached. Sufficient adhesion must be granted (i. m.
1.5 N/mm2). Prior to grouting, the surface must be wetted continuously for approx. 6 hours till saturation.
FORMWORK: Must be of rigid construction, with sand or dry mortar being placed around the concrete base carefully to
prevent leakage.
MIXING: The grout is ready for use, only water is to be added (10–12 % or 2.5–3 l per bag). Measure out the correct
quantity of water and fill two thirds of this into a concrete mixer, add the dry mortar and mix for about
3 minutes. Then fill in the remaining water and mix for another 2 minutes. Grouting then should take place
immediately.
GROUTING: Place the mixed grout from one side or corner only in one continuous pour. When grouting large areas we
suggest to pour starting from the middle – using a pipe or funnel. On machine installations fill the anchor bolt
pockets first (up to approximately top of anchor bolt pockets) and then the underside of the machine. Potlife:
approx. 120 min.
CAUTION: Open areas must be protected against wind, draught and premature evaporation by using for example plastic
foil or O1 PAGEL-CURING AGENT.
Grouting shoulders:
Heights and shoulders around base plates must not exceed 50 mm.
Temperature:
Application between 5°C und 35 °C, low temperature working conditions retard the strength development and
reduce the flowability while high temperatures accelerate the same.
Non-Iron-Metals:
Cement as well as all cement-bound building materials may under certain circumstances cause a coming-off
of non-iron-metals in the application area (for exemple aluminium, copper, zinc) please ask for our technical
service.
Having prefabricated units grout is being used according to DIN 1045 (6.7.1) for joints, between
components and overlyings.
PAGEL-GROUT belongs according to DIN 1045 to the subject heading cement mortar (2.1.3.1)
and is in need of a General Construction Permission with a Corresponding Certificate for the additives.
PAGEL-CONCRETE-GROUT belongs to the subject heading concrete (BI and BII) and meets
most of the demands of a concrete with special characteristics (6.5.7) (resistant to water, highly
resistant to frost, highly resistant to chemical attacks).
Soucre material for PAGEL-GROUT:
Cement according to DIN 1164
Surcharge: according to DIN 4226 (eFT)
Additional material: General Construction Permission.
Additives: General Construction Permission.
FIELDS OF APPLICATION
turbines, generators, compressors, diesel engines and other power equipment operating under heavy vibration
FIELDS OF APPLICATION
funnel
for pump
Air vent Air vent
The information provided in this leaflet, is supplied by our consulting service and is the
end result of exhaustive research work and extensive experience. They are,
however, without liability on our part, in particular with regard to third parties
proprietary rights, and do not relieve the user of the responsibility for verifying that the
products and processes are suitable for the intended application. The data
presented was derived from tests under normal climate conditions according to DIN
50014 and mean average values and analysis. Deviations are possible when delivery SPEZIAL-BETON GMBH & CO. KG
takes place. Given that recommendations may differ from those shown in this leaflet
written confirmation should be sought. It is the responsibility of the purchaser to WOLFSBANKRING 9 · D-45355 ESSEN
ensure they have the latest leaflet issue and that its contents are current. Our
TEL. +49 (0)2 01–6 85 04-0 · FAX +49 (0)02 01–6 85 04-31
customer service staff will be glad to provide assistance at any time. We appreciate the
EN ISO 9001
interest you have shown in our products. This technical data sheet supercedes
INTERNET: WWW.PAGEL.COM · E-MAIL: [email protected]
previously issued information. Please find the latest leaflet issues at www.pagel.com.
V1/50 ®
V1/10 ®
V1/160
®