0% found this document useful (0 votes)
141 views1 page

Seminar On " To Increase The Reliability of Cooling System at Blast Furnace"

The document summarizes a seminar on increasing the reliability of cooling systems at blast furnaces. It discusses how cooling systems are important for removing excess heat from blast furnaces to prevent overheating. There are two circuits in cooling systems - a primary circuit where demineralized water flows and a secondary circuit where industrialized water flows to cool the primary circuit. However, problems from the industrialized water like fouling, scaling, deposits and biofouling reduce the efficiency and flow rate of the cooling system. The seminar will describe processes and devices that can overcome these problems to improve the reliability of blast furnace cooling.

Uploaded by

Lipsha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views1 page

Seminar On " To Increase The Reliability of Cooling System at Blast Furnace"

The document summarizes a seminar on increasing the reliability of cooling systems at blast furnaces. It discusses how cooling systems are important for removing excess heat from blast furnaces to prevent overheating. There are two circuits in cooling systems - a primary circuit where demineralized water flows and a secondary circuit where industrialized water flows to cool the primary circuit. However, problems from the industrialized water like fouling, scaling, deposits and biofouling reduce the efficiency and flow rate of the cooling system. The seminar will describe processes and devices that can overcome these problems to improve the reliability of blast furnace cooling.

Uploaded by

Lipsha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Seminar

On
“ To Increase The Reliability of Cooling System at Blast Furnace”
Delivered by: Under the guidance of:
Debajani Sarangi
Dept. Of Mechanical Engg.
Regd. No.:1601106543
Date:
ABSTRACT:
Function of Blast furnace cooling system is to cool the furnace shell
and prevent from the overheating and subsequent burn through. Cooling
system removes the excess heat generated in the blast furnace which is
otherwise loaded on the shell. Thus it prevents the increase of shell and
lining temperature and maintains the orientation of furnace shell. There are
two types of circuits in the cooling system named primary and secondary
circuit. Demineralised water flows through primary circuit and
Industrialised water flows through secondary circuit.
Secondary circuit is used to cool primary circuit. But due to some known
and unknown problems Cooling system is not working effectively. As
Demineralised water is free from minerals, so the problem is created due to
Industrialised water. The problems are:- Fouling, Scaling, Deposits, Bio
fouling. The impacts of these problems are:- (i) Reduced heat exchanger
efficiency, (ii) Heat exchanger plugging, (iii) Reduces Flow rate, (iv)
Reduced cooling tower efficiency, (v) Increases overall thermal resistance,
(vi) Increases Maintenance requirements, (vii) Increases cost. By the
application of some processes and some device these problems can be
overcome which will be described in the presentation.

[1] Er. R.K. RAJPUT , “ Heat and Mass Transfer” , S.CHAND publications.
[2] Binay K. Dutta ,Principles of Mass Transfer and Separation Process.
[3] www.planystech.com
[4] http://www.mts.com
[5] https://www.scibd.com ( BPG cooling towers)
[6] www.ariah.org.au
[7] www.qldwatersolutions.com.au
[8] https://www.merusonline.com
[9] www.scalebanindia.com