This document provides instructions for using a computer RS232 socket and summarizes the specifications and features of several shipping scale models. The scales can be powered by batteries or an optional AC adapter and have capacities ranging from 30kg to 150kg. Safety precautions are outlined and calibration procedures described. Features include auto shut-off, tare and hold functions, and the ability to switch between kg and lb units. Proper weighing technique and error messages are also summarized.

Uploaded by

Chris Mathew
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
452 views4 pages

Manual FCS

This document provides instructions for using a computer RS232 socket and summarizes the specifications and features of several shipping scale models. The scales can be powered by batteries or an optional AC adapter and have capacities ranging from 30kg to 150kg. Safety precautions are outlined and calibration procedures described. Features include auto shut-off, tare and hold functions, and the ability to switch between kg and lb units. Proper weighing technique and error messages are also summarized.

Uploaded by

Chris Mathew
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

The use method of computer RS232 socket: refer to photo Disk.

ASC II code receive parameter ( the RS232 transfer parameter) COMMERCIAL


Baud rate 9600
Parity bit none SHIPPING SCALE
Data bit 8
Stop bit 1

INSTRUCTION MANUAL
SAFETY PRECAUTIONS
SPECIFICATIONS
All safety messages are identified by the words "WARNING" and "CAUTION". Model number Capacity Division
These words mean the following: FCS-30 30kg 10g
FCS-60 60kg 20g
△, WARNING
! Important information to alert you to a FCS-100 100kg 20g/50g
situation that might cause serious injury and FCS-150 150kg 50g/100g
damage to your property if instructions are
not followed. Platter / Tray 330×320mm
△, CAUTION
! Important information that tells how to prevent Net/gross weight 4.1kg/4.5kg
damage to the equipment. Package Standard carton: 44.5×34.6×7(cm3)
5 Units in one box: 46×36×39(cm3)
When using the scale, the following safety precautions should always be followed. Operating Optimum: 15-30℃ (62-90f)
Temperature
△, WARNING
!
6×AA Batteries or AC/DC
Use only the correct AC adaptor with the scale. Other adaptors may cause Power source
Adapter 9~12V/100mA (optional)
permanent electrical damage.

△, CAUTION
!
**SPECIAL WARNING**
Cell-Phones, Cordless-Phones, and any radio-frequency device can
Avoid placing the scale in direct sunlight, this may cause discoloration or cause temporary interference and cause the scale to temporarily not
malfunction.
work properly. Please do not use any electronic device near the
Replace all batteries at the same time – Do not replace only a portion of the 6 shipping scale. Just like in an Airplane, do not use your cell-phone
batteries as this may cause a malfunction.
near the scale when it is in use. While there is NO risk of
If the scale is not to be used for a long period of time, remove all batteries from the permanent damage to the scale, interference can cause an incorrect
battery compartment to avoid leakage, which may cause damage to this scale.
calibration or incorrect weight readings.
Avoid overloading the scale, as this may cause permanent damage and void
your warranty – do not EVER exceed the maximum capacity of the scale
Keep the scale away from water – this scale is not water resistant. Shock, injury
and electrical damage can occur if used in a wet location!
Matter charged with static electricity could affect accuracy. Discharge all static
electricity. For example, one method is to use Static-Guard spray, and spray it on
both sides of the weighing platform.
6
1
CALIBRATION PARTS DESCRIPTION
When to calibrate - calibration is almost never required. SIDE
If the scale is inaccurate, calibration may be desired when the scale is first set up for AC adaptor
use, or if the scale is moved to a different altitude or gravitation. This is necessary Socket
because the weight of a mass in one location is not necessarily the same in another
location. Also, with time and use, mechanical deviations can occur.
ON/OFF key
How to calibrate Turns the scale
**you must have an accurate the full load kilogram weight or combination of power on/off.
weights in order to calibrate**

1. The scale must be powered OFF. Press and hold [ZERO] first, then Press HOLD KEY
Remain on the display for 120 seconds.
[ON/OFF] while keeping the [ZERO] button depressed, then release both keys.
The display will show the A/D value (a series of random numbers).
2. Wait for the stable indicator to be displayed, Press [UNIT] the display will show UNIT key
Changes weighing units, eg. kg or lb,.
"0SAVE", then the display will return to the random A/D value.
3. Place the full load kilograms weight(s) on platform. Wait for the stable indicator
to display, then press [UNIT], the display will show "0SAVE". Calibration is ZERO key (for TARE)
complete, remove the weight(s). Sets display to zero or
4. Turn the scale OFF (Press the ON/OFF key) , then turn it back ON and check
some weight readings. If calibration is still incorrect, repeat calibration but try it Subtracts weight of a container.
more slowly.
If calibration is repeatedly incorrect then: 1) Replace the batteries, 2) Try a more
stable surface or vibration and interference free location, 3) Be sure there is no DISPLAY
static electricity on the scale (use an anti-static spray to remove static electricity) Negative value indicator Weighing unit

Stable indicator
Indicates when the A/D value
reading is stable
FEATURES
 Auto shut off (optional) ● Auto calibration
 Auto zero tracking ● AC Power (optional) Low battery indicator
 Removable display w/3ft cord ● kg /lb conversion Hold indicator ZERO indicator
 Large LCD (6digits 15 mm high) ● hold function Indicates when the reading is stable
 Large square weighing tray.

5 2
HOLD(send data) FUNCTION
Once the hold key is pressed: 1). The CPU will send weight data into RS232 WEIGHING
socket. 2)the weight will remain on the display for 120 seconds after the item
has been removed from the scale so the weight can easily be read. Before weighing
Whenever possible, please allow the scale to warm up for several seconds after first
1) Place the item on the scale platform. turning the power on so that the scale will function properly and accurately.
2) Wait for the stable weights to be displayed.
Error messages
3) Press the hold key. The “.” hold indicator will turn-on. EEEE: Overload
4) Remove the item from the scale platform. The item’s weight : Low battery
reading will remain on the display for 120 seconds.
5) Quit to hold function: Once an item is weighed and the hold function is
enabled; you want to quit to hold function, Press the hold key again to Weighing procedures
cancel the “.” hold indicator and return the scale to weight value. 1. Press [ON/OFF] to turn on the scale.
When the power is turned on, all display segments appear for a few seconds and "0"
will appear on the display.
FUNCTION SETTINGS
2. Select the weighing unit with [UNIT].
1. Enter function setting mode.
Press [ON/OFF] to turn the power off, Press [HOLD] first, then press Press [UNIT] to select a weighing unit "kg", "lb".
[ON/OFF], while keeping [HOLD] pressed, the display will show A_ON or Once the unit has been selected, the selected unit will be displayed next to the
weight value.
A_OFF.
3. Start weighing
2. Selection of auto shut off mode.
When the balance enter function setting menu. the display will show A_ON or
If you do not use a container for weighing,
A_OFF, Press [ZERO] key, selection display A_ON, this means auto shut off
Verify the reading is "0". If not, press [ZERO/TARE] to display "0".
function active. Press [ZERO] again, the display will show A_OFF, this Place the items to be weighed on the platform.
means auto shut off function inactive. When the reading becomes stable, the stable weighing is displayed.

If you use a container for weighing,


Place an empty container on the platform.
Wait for the stability indicator to be displayed and press [ZERO/TARE].
Place the objects to be weighed in the container.
When the reading becomes stable, the stable weighing displayed.