Atmos LDS and Batch For Pertamina UPMS CY3 Multiproduct Pipeline
Atmos LDS and Batch For Pertamina UPMS CY3 Multiproduct Pipeline
Atmos International Ltd Atmos International Inc Atmos International Atmos International
St Paul's 781 3100 E. Miraloma Ave Latin America 705 RuiChen International Center
Wilmslow Road Suite 240 D, Anaheim #2 Torre Málaga No13 Nongzhanguan South Road
Manchester, UK California, USA Calle 0 y Avenida 1 Chao Yang District
Tel +44-161-445-8080 Tel +1-714-520-5325 Cuidad Colon de Mora Beijing, China
Web: www.atmosi.com Web: www.atmosi.com San Jose, Costa Rica Tel +86-10-6503-3031
Tel +506-8894-3063 Web: www.atmosi.com
Web: www.atmosi.com
CY3 Multiproduct Pipeline
Multiproduct Pipeline
❑ 179km 16”
❑ From Lomanis to Rewulu
❑ No flow meter at inlet and outlet of the pipeline
❑ No density meter at inlet and outlet of the pipeline
❑ No MOV at inlet (MOV outlet of the pipeline is
present)
CY3 Multiproduct Pipeline
Requirement:
❑ Leak Detection and Theft Detector (pipeline security)
❑ Batch Tracking software
CY3 Multiproduct Pipeline
Custody meter
Menu
Totalisers
• Menu
• Totalisers
• Custody meter
Warning indicator
• Warning indicator
• Navigation panel
• Events
Navigation panel
Events
Atmos Batch – GUI Example 2
Batch
locations on a
pipeline
running from
Vancouver to
Edmonton
Each colour
represents a
different
product
Atmos Batch – Instrumentation Requirement
Fibre
Optic
Eclipse
Eclipse
DTx DTx
FTx
MOV MOV
KP 0 KP 90 KP 179
Speed of Sound
FTx Clamp-on DTx
Signal
Flow Transducer
LEAK DETECTION +
THEFT DETECTION
Atmos Wave Flow
➢ Redundant leak detection system
➢ Two leak alarms provided to operators to provide more
confidence for operator to make emergency action
➢ Primary leak detection using Negative Pressure Wave
method utilizing high speed pressure sensor
➢ Secondary leak detection using Mass Balance + RTTM
method utilizing clamp-on flow transducer within Atmos
Eclipse
➢ Speed of sound signal using clamp-on flow transducer
with Atmos Eclipse to improve location accuracy.
➢ Calculation of leak flow rate using clamp-on flow
transducer.
Atmos Wave Flow
➢ 6-in-1 box
➢ What is in the box ?
o AWAS DAU with GPS antenna
o Clamp-on flow transducer
o Temperature sensor
o Pressure sensor
o Clamp-on PT or external PT
o Speed of sound measurement
o Communication (TCPIP, RS485, 3G, Radio)
➢ IP66
➢ Explosion proof
➢ Pipe diameter: 3”-24”
Atmos Wave Flow for CY3 – Configuration
Fibre
Optic
Eclipse
Eclipse
MOV MOV
Min 20m Min 20m
KP 0 KP 90 KP 179
WIKA
PTx High Speed FTx Clamp-on
Flow Transducer
Pressure Sensor
Advantages of Atmos Wave Flow