0% found this document useful (0 votes)
52 views2 pages

Code References: General Information

This document summarizes the structural analysis of a HSS6x6x5/8 steel column subjected to an axial load of 94 kips. The 13.5 foot tall column was analyzed according to AISC 360-05 and ASCE 7-05 standards using allowable stress design. All load combinations were found to result in stress ratios below allowable limits, indicating the column is adequately designed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views2 pages

Code References: General Information

This document summarizes the structural analysis of a HSS6x6x5/8 steel column subjected to an axial load of 94 kips. The 13.5 foot tall column was analyzed according to AISC 360-05 and ASCE 7-05 standards using allowable stress design. All load combinations were found to result in stress ratios below allowable limits, indicating the column is adequately designed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Title : Job #

Description : C1_AXIAL_94 KIPS

.
Code References
Calculations per AISC 360-05, ASCE 7-05
Load Combinations Used : 2012 IBC & ASCE 7-10
General Information
Steel Section Name : HSS6x6x5/8 Overall Column Height 13.50 ft
Analysis Method : Allowable Stress Top & Bottom Fixity Top Pinned, Bottom Fixed
Steel Stress Grade
Fy : Steel Yield 46.0 ksi Brace condition for deflection (buckling) along columns :
E : Elastic Bending Modulus 29,000.0 ksi X-X (width) axis : Unbraced Length for X-X Axis buckling = 13.50 ft, K = 1.0
Load Combination : 2012 IBC & ASCE 7-10 Y-Y (depth) axis : Unbraced Length for X-X Axis buckling = 13.50 ft, K = 1.0

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 568.31 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 13.50 ft, D = 60.0, L = 34.0 k
DESIGN SUMMARY .
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.4269 : 1 Maximum SERVICE Load Reactions . .
Load Combination +D+L+H Top along X-X 0.0 k
Location of max.above base 0.0 ft Bottom along X-X 0.0 k
At maximum location values are . . . Top along Y-Y 0.0 k
Pa : Axial 94.568 k Bottom along Y-Y 0.0 k
Pn / Omega : Allowable 221.518 k
Ma-x : Applied Maximum SERVICE Load Deflections . . .
0.0 k-ft
Mn-x / Omega : Allowable 53.253 k-ft Along Y-Y 0.0 in at 0.0ft above base
for load combination :
Ma-y : Applied 0.0 k-ft
Mn-y / Omega : Allowable 53.253 k-ft Along X-X 0.0 in at 0.0ft above base
for load combination :
PASS Maximum Shear Stress Ratio = 0.0 : 1
Load Combination
Location of max.above base 0.0 ft
At maximum location values are . . .
Va : Applied 0.0 k
Vn / Omega : Allowable 0.0 k
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination Stress Ratio Status Location Stress Ratio Status Location
+D 0.273 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+L+H 0.427 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+Lr+H 0.273 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+S+H 0.273 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+0.750Lr+0.750L+H 0.389 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+0.750L+0.750S+H 0.389 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+0.60W+H 0.273 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+0.70E+H 0.273 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+0.750Lr+0.750L+0.450W+H 0.389 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+0.750L+0.750S+0.450W+H 0.389 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+0.750L+0.750S+0.5250E+H 0.389 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.60D+0.60W+H 0.164 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.60D+0.70E+H 0.164 PASS 0.00 ft 0.000 PASS 0.00 ft
Maximum Reactions - Unfactored Note: Only non-zero reactions are listed. .
X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
D Only k k 60.568 k
L Only k k 34.000 k
Description : C1_AXIAL_94 KIPS

Maximum Reactions - Unfactored Note: Only non-zero reactions are listed.


X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
D+L k k 94.568 k
Maximum Deflections for Load Combinations - Unfactored Loads .
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
L Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
D+L 0.0000 in 0.000 ft 0.000 in 0.000 ft
Steel Section Properties : HSS6x6x5/8 .
Depth = 6.000 in I xx = 55.20 in^4 J = 94.900 in^4
Web Thick = 0.000 in S xx = 18.40 in^3
Flange Width = 6.000 in R xx = 2.170 in
Flange Thick = 0.624 in
Area = 11.700 in^2 I yy = 55.200 in^4
Weight = 42.097 plf S yy = 18.400 in^3
R yy = 2.170 in

Ycg = 0.000 in

94.0k

Height = 13.50 ft
6.00in

Load 1 X

6.00in Loads are total entered value. Arrows do not reflect absolute direction.