IDLC-45: 45W Constant Current Mode LED Driver
IDLC-45: 45W Constant Current Mode LED Driver
IDLC-45: 45W Constant Current Mode LED Driver
F M M SELV
■ Features ■ Applications
Constant Current mode output LED panel lighting
Flicker free design LED flood lighting
Plastic housing with class II design Indoor LED lighting
Built-in active PFC function
No load power consumption<0.5W(Blank-Type)
Function options: 2 in 1 dimming (dim-to-off);
Auxiliary DC output
3 years warranty
■ Description
IDLC-45 series is a 45W LED AC/DC driver featuring the constant current mode output with flicker
free design.IDLC-45 operates from 90~295VAC and offers models with different rated current
ranging between 350mA and 1400mA. Thanks to the efficiency up to 86%, with the fanless design,
the entire series is able to operate for -20℃~+85℃ case temperature under free air convection.
IDLC-45 is equipped with various function options, such as dimming methodologies, so as to
provide the optimal design flexibility for lighting system.
■ Model Encoding
IDLC - 45 A - 500
Function options
Rated wattage
Series name
INRUSH CURRENT (Typ.) COLD START 30A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
PROTECTION SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP. Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level( surge immunity:Line-Line:1KV )
MTBF 408.8Khrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 120*75*25mm(L*W*H)
PACKING 0.22Kg; 54pcs/ 13Kg/ 0.93CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De-rating may be needed under low input voltages. Please refer to STATIC CHARACTERISTIC sections for details.
4. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
5. There is no design of short circuit protection for the Auxiliary DC output; this function can not be used when dimming input terminals(DIM+,DIM-)
are short circuit or when it is no load or short circuit at output(Vo+,Vo-).
6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
Block Diagram
fosc : 70KHz
AUX+(for A-Type)
RECTIFIERS
AUX-(for A-Type)
O.L.P. DETECTION
PWM&PFC CIRCUIT
CONTROL
※ This series works in constant current mode to directly drive the LEDs.
In the constant current region, the highest voltage at the output of the driver
100 depends on the configuration of the end systems.
Constant Should there be any compatibility issues, please contact MEAN WELL.
Vo(%)
Current area
60
(min.)
Hiccup
Protection
50 100 Io(%)
DIMMING OPERATION
※ 2 in 1 dimming function
ACL
ACL TB1
ACN
ACN
DIM+
DIM-
Vo+ TB2
Vo-
Output constant current level can be adjusted by applying one of the two methodologies between DIM+ and DIM-:
0 ~ 10VDC, or 10V PWM signal.
Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
60%
-
Vo- - 50%
DIM+ 40%
+
30%
Additive Voltage
- 20%
DIM-
10%
◎ Applying additive 10V PWM signal (frequency range 300Hz ~ 3KHz): 100%
90%
80%
+
Vo+ + 70%
Output current (%)
60%
-
Vo- - 50%
DIM+ 40%
Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< I out<8%.
2. The output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle.
90~295VAC for 350mA Model,200~295VAC for others 90~295VAC for 350mA Model,200~295VAC for others
100 100
80 80
LOAD (%)
40 40
20 20
※ Tcase at 75℃
100
80 0.95
115V
PF
60
0.85
230V
50
0.8 277V
40
0.75
90 135 180 200 295
0.7
LOAD
※ De-rating is needed under low input voltage.
14 88
12
86
EFFICIENCY(%)
10
THD(%)
277V 84 277V
8
230V 230V
6 82
115V 115V
4 80
2 78
0
76
50% 60% 70% 80% 90% 100%
50% 60% 70% 80% 90% 100%
LOAD
LOAD
MECHANICAL SPECIFICATION
※ Blank-Type Case No.IDLC-45A Unit:mm
120
6.5
tc : Max. Case Temperature
1
2 TB1
6.5
3
4
1
75
2
3 TB2 30
4 tc
6.5
30
6.5
25
3
※ A-Type
120
6.5
tc : Max. Case Temperature
1
2
3 TB1
6.5
1
75
2
3 TB2 30
4 tc
5
6.5
6
30
6.5
25
3
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html