CATALOGO Generale VMC PDF
CATALOGO Generale VMC PDF
CATALOGO Generale VMC PDF
TECHNICAL DATA:
Size R20 R40 R90
Rate Flow fully open m³/1' 2,5 5,5 10
Nominal Diameter mm 38 50 70
Working pressure mm Up to 16 bar Up to 16 bar Up to 16 bar
Type R… NR for Non-return control
R... E for On/Off start-up system with suction control valve closed
R… EP for On/Off and Stepless control with suction control valve closed
R… PM for Mobile compressor with suction control valve open
Optional I = Air Injection system to keep system pressurized during idling
H= Horizontal Junction Filter (see the drawing )
V = Vertical Junction Filter (see the drawing )
Adjustment Adjustable control device to unload vessel through inlet manifold during idling
Solevalve voltage 24V, 110V or 230V
Materials Housing in Aluminium alloy anodized. Internal parts in Aluminium alloy anodized, Viton sealings, and Brass.
Weight Kg 1,6 3 4
DIMENSION DETAILS:
Size R20 R40 R90
Bolt holes Nr. 4 4 4 4 4
X mm 54,5 54,5 77 77 84
Y mm 100 100 135 125 150
Z_V mm 152 152 247 247 295
K mm 130 130 172 172 191
W mm 40 40 53 53 72
V mm 48 48 60 60 80
J mm 127 127 145 140 155
I1 mm 105 104 129 110 143
I2 mm 110 116 150 135 170
I3 Ø 11 9 13 13 17
O1 mm 70 82 107 90 113
O2 mm 76 88 113 96 119
O3 mm - - - 70 -
O4 mm - - - 76 -
Z_H mm 145 145 237 237 262
Attention: The drawing below is not appropriated to all models. Looks in our website all specific draws.
APPLICATION: Installed at the compressor inlet to control compressor capacity. At the start-up the valve stays open till a control signal is ap-
plied to close the valve and restrict the flow. During normal operation the valve open and close in response to a control signal to meet the air demand.
At the shut-down a check valve stays closed to prevent back flow through the compressor. The valve can be ordered in the non-return working system.
INSTALLATION: At the suction flange of the air-end, either directly or by flange adaptor, depending on the type of air-end. The ON/OFF system
must be connect to the signal pressure and solenoid valve.
REPLACEMENT: The stress on valve parts depends on compressor application and operating parameters. Inspect the valve and replace, using
VMC spare part kit, after 6.000 operating hours.
Attention: The drawing below is not appropriated to all models. Look at in our website all specific draws.
*Note: 73mm less for the “No-return models”
Via Almerico da Schio, 4/A-B - 36051 Creazzo (VI) ITALY - Tel. +39 0444 521471 / 341115
Solutions for winner compressors Fax +39 0444 275112 - [email protected] - www.vmcitaly.com
Intake Valve
RH Series
APPLICATION: Installed on the compressor inlet to control its capacity. At start-up, the valve remains open till the minimum suction
pressure closes the valve. During normal operation, the valve opens and closes in response to a this signal that meets the air demand.
At shutdown, a check valve remains closed and keeps the suction. The valve is also available in the non-return and proportional version.
INSTALLATION: On the suction flange of the air-end, either directly or by flange adaptor, depending on the type of air-end. The ON/OFF
system must be connected to the pressure signal and solenoid valve.
REPLACEMENT: The stress on valve parts depends on compressor application and operating parameters. Replacement should take
place with VMC spare parts kit after 8.000 operating hours.
TECHNICAL DATA
SizeAir Flow RH30 RH38 RH60 RH70
Flow rate fully open m /min-cfm
3
See the diagram
Working System Non-return or On/Off Non-return Non-return, On/Off Non-return, On/Off
Available or On/Off and Proportional and Proportional
Working pressure up to 16 bar - up to232 psi
Solenoid-valve voltage 24V, 110V or 230V
Materials Unit is made in aluminium alloy. Inside parts in aluminium alloy, stainless steel, brass, viton sealings and PTFE
Adjustment Adjustable control device to unload vessel through inlet manifold during idling
Circular base Rectangular base
X mm-inch 90 - 3,54 115 - 4,52 125 - 4,92 126 - 4,96 127 - 5
Y mm-inch Ø84 - Ø3,3 80x73 - 3,15x2,87 100 - 3,94 135 - 5,31 150 - 5,9
*Z_V mm-inch 132 - 5,2 155 - 6,1 132 - 5,19 194 - 7,63 203 - 7,99
K mm-inch 64 - 2,52 80,5 - 3,17 124,5 - 4,9 162 - 6,37
W mm-inch Rp 1” Ø20 - 0,78 Ø20 - 0,78 Rp 1” Ø20 - 0,78 Ø20 - 0,78 Ø42 - Ø1,65 Ø73 - Ø2,87 Ø70 - Ø2,75
V mm-inch Ø40 - 1,57 Ø30 - 1,18 Rp 3/4” Ø40 - 1,57 Ø30 - 1,18 Rp 3/4” Ø52 - Ø2,04 Ø80 - Ø3,15 Ø80 - Ø3,15
I1 mm-inch Ø73 - Ø2,87 62x55 - 2,44x2,16 Ø100 - Ø3,93 Ø129 - Ø5,07 Ø143 - Ø5,63
I2 mm-inch - Ø115 - Ø4,52 Ø150 - Ø5,9 Ø170 - Ø6,7
I3 mm-inch Ø7,2 - Ø0,28 Ø8,5 - Ø0,33 Ø9 - Ø0,35 Ø12,5 - Ø0,49 Ø17 - Ø0,67
I4 mm-inch - Ø10,2 - Ø0,4 Ø16,5 - Ø0,65 Ø17 - Ø0,67
O1 mm-inch Ø59,5 - Ø2,34 Ø70 - Ø2,75 Ø95 - Ø3,74 Ø118 - Ø4,64
O2 mm-inch Ø63,5 - Ø2,5 Ø76 - Ø3 Ø101 - Ø3,97 Ø124 - Ø4,88
O3 mm-inch - Ø82 - Ø3,22 Ø107 - Ø4,2 -
O4 mm-inch - Ø88 - Ø3,46 Ø113 - Ø4,45 -
Weight kg - lb 0,6 - 1,32 0,8 - 1,76 1,5 - 3,3 2,7 - 5,95
Attention: The drawing below is not suitable for all models. Please log on to our webiste for specific drawings.
www.vmcitaly.com
Intake Valve
RH100 - RH180 - RH350 - RH600
TECHNICAL DATA:
Size RH 100 RH 180 RH 350 RH 600
Rate Flow fully open m³/1' 14 18 35 60
Nominal Diameter mm 82 90 140 190
Working pressure mm Up to 16 bar Up to 16 bar Up to 16 bar Up to 16 bar
Type RH… NR for Non-return control
RH... E for On/Off start-up system with suction control valve closed
RH… EP for On/Off and Stepless control with suction control valve closed
RH… PM for Mobile compressor with suction control valve open
Optional I = Air Injection system to keep system pressurized during idling
Adjustment Adjustable control device to unload vessel through inlet manifold during idling
Solevalve voltage 24V, 110V or 230V
Materials Housing in Aluminium alloy anodized. Internal parts in Aluminium alloy anodized, Viton sealings, Teflon coating.
Weight Kg 5,2 8 15 25
DIMENSION DETAILS:
Size RH100 RH180 RH350 RH600
Bolt holes Nr. 4 4 8 8 12 12
X mm 169 214 214 270 270 327
Y mm 150 250 250 340 340 460
Z_V mm 242 337 337 435 435 555
K mm 198 210 210 231 231 257
W mm 82 90 90 140 140 190
V mm 100 110 110 150 150 206
I1 mm 160 - 225 225 295 410
I2 mm 180 170 - - - -
I3 Ø 17 17 17 17 21 25
O1 mm 113 140 196 196 248 330
O2 mm 119 145 203 203 259 342
Attention: The drawing below is not appropriated to all models. Look at in our website all specific draws.
APPLICATION: Installed on the compressor inlet to control compressor capacity. During normal operation the valve open and close
in response to a control signal to meet the air demand. Stepless or two point capacity controls are available. At the shut-down a
check valve stays closed to prevent back flow through the compressor also if the air flow is interrupted. Many solutions are available
for stationary or mobile compressors.
INSTALLATION:On the suction flange of the air-end, either directly or by flange adapt or, depending on the type of air-end. The valve
must be connect to the signal pressure and solenoid valve.
REPLACEMENT: The stress on valve parts depends on compressor application and operating parameters. Inspect the valve and
replace, using VMC spare parts kit, after 8.000 operating hours.
TECHNICAL DATA
SizeAir Flow RB60 RB80 RB90 RB115 RB125 RB140 RB200
Flow rate fully open m3/min-cfm See the diagram
Nominal Diameter mm-inch Ø60 - Ø2,36 Ø80 - Ø3,15 Ø90 - Ø3,54 Ø115 - Ø4,52 Ø125 - Ø4,92 Ø140 - Ø5,5 2xØ140 - N°2x Ø 5,5
Working pressure up to 16Bar - up to 232 psi
Working system Available RB…NR for Non-return control
RB…E for On/Off start-up system with suction control valve closed
RB…P for Stepless control with suction control valve closed
RB…PM for Mobile compressor with suction control valve open
Adjustement Adjustable control service to unload vessel through inlet manifold during idling
Solenoid valve Voltage 24V, 110V or 230V
Materials Housing in Aluminium alloy anodized. Internal parts in Stainless Steel, Viton sealings, and Brass.
Weight kg - lb 2,2 - 4,85 3 - 6,6 6,5 - 14,33 10 - 22 12 - 26,45 12,3 - 27,1 25,3 - 55,77
www.vmcitaly.com
Intake Valve
RB Series
TECHNICAL DATA
Size RB60R RB60T RB60GTr RB80 RB90 RB115 RB125 RB140 RB200
Bolt holes Nr. 4 4 4 4 4 8 8 12 12
Y mm-inch 125 - 4,92 135 - 5,3 135 - 5,3 155 - 6,1 155 - 6,1 Ø255 - Ø10 Ø285 - Ø11,22 Ø340 - Ø13,38 Ø460 - Ø18,1
Z-V mm-inch 177 - 6,96 177 - 6,96 177 - 6,96 203 - 8 310 - 12,2 300 - 11,8 345 - 13,58 351 - 13,81 500 - 19,68
K mm-inch 197 - 7,75 197 - 7,75 197 - 7,75 230 - 9,05 238 - 9,37 308 - 12,12 308 - 12,12 321 - 12,63 350 - 13,77
V mm-inch Ø70 - Ø2,75 Ø70 - Ø2,75 Ø70 - Ø2,75 Ø100 - Ø3,93 Ø100 - Ø3,93 Ø150 - Ø5,9 Ø150 - Ø5,9 Ø150 - Ø5,9 N°2xØ150 - N°2x Ø5,9
I1 mm-inch Ø110 - Ø4,33 Ø129 - Ø5,07 - Ø150 - Ø5,9 Ø160 - Ø6,3 Ø225 - Ø8,85 Ø240 - Ø9,45 Ø295 - Ø11,6 Ø410 - Ø16,14
I2 mm-inch Ø135 - Ø5,3 Ø150 - Ø5,9 Ø150 - Ø5,9 Ø180 - Ø7,1 Ø180 - Ø7,1 - - - -
I3 mm-inch Ø13 - Ø0,51 Ø13 - Ø0,51 Ø17 - Ø0,67 Ø17 - Ø0,67 Ø17 - Ø0,67 Ø17 - Ø0,67 Ø21 - Ø0,82 Ø21 - Ø0,82 Ø25 - Ø0,98
01 mm-inch Ø86 - Ø3,38 Ø107 - Ø4,21 Ø107 - Ø4,21 Ø123 - Ø4,84 Ø127 - Ø5 Ø195 - Ø7,67 Ø195 - Ø7,67 Ø248 - Ø9,76 Ø329,5 - Ø12,97
02 mm-inch Ø92 - Ø3,62 Ø113 - Ø4,45 Ø113 - Ø4,45 Ø129 - Ø5,07 Ø133 - Ø5,23 Ø203 - Ø7,99 Ø203 - Ø7,99 Ø259 - Ø10,2 Ø341,5 Ø13,44
Attention: The drawing below is not suitable for all models. Please log on to our webiste for specific drawings.
www.vmcitaly.com
SERVICE KITS VMC
OPERATION: The Minimum Pressure Valve which is installed after the oil separator, has two functions:
• during start-up, the valve remains closed until the opening set-up pressure. Then it opens in order to maintain minimum pressure in
the air-oil separator. In this way, pressure can lubricate the compressor unit;
• during shutdown, the check valve is closed to prevent backflow from the line through the compressor.
INSTALLATION: The Minimum Pressure Valve is installed at the discharge port of the separator. It can be threaded or flanged.
REPLACEMENT: It depends on compressor applications and working conditions. Valve inspection and its replacement is recommended
8.000 running hours. VMC original spare parts have to be used.
TECHNICAL DATA
Air Flow rate fully open m3/min-cfm 1 - 35,31 1,5 - 52,965 3,5 - 123,58 6 - 211,86 12 - 423,72 22 - 776.82 40 - 1412,4 60 - 2118,6
Pressure Drop bar-psi From 0,03 to 0,2 Bar From 0,435 to 2,9 psi
Materials Housing in Aluminium alloy anodized. Internal parts in Stainless Steel, Viton sealings, and Brass.
Set opening pressure bar-psi From 3 to 5,5. Standard settings 4,5 ± 0,25 From 43,5 to 79,8 psi.Standard settings 65,25+or- 3,6 psi
Threaded Version G10 1/2” G10 3/4” G26 G36 G46 G50T Flanged Flanged
1’ version only version only
X Rp 1/2” Rp 3/4” Rp 1” Rp 1-1/4” Rp 1-1/2” Rp 2” - -
Y mm-inch 86 - 3,38 86 - 3,38 106 - 4,17 132 - 5,2 196 - 7,7 276 - 10,86 - -
Z mm-inch 32 - 1,26 32 - 1,26 50 - 1,97 61 - 2,4 59 - 2,32 67,5 - 2,65 - -
L mm-inch Rp 1/2” Rp 3/4” Rp 1” Rp 1-1/4” Rp 1-1/4” Rp 2” - -
K (hexagon) mm-inch 36 - 1,41 36 - 1,41 45 - 1,77 55 - 2,16 70 - 2,75 86 - 3,38 - -
W mm-inch 33 - 1,3 33 - 1,3 38,5 - 1,51 47,5 - 1,87 70 - 2,75 70,5 - 2,77 - -
Weight kg-lb 0,3 - 0,66 0,3 0,66 0,6 - 1,32 1 - 2,2 1,8 - 3,96 3,2 - 7 - -
Flanged Version Threaded Threaded G25F G35F G40F G50 G55R G60R
1’ version version
only only
X mm-inch Ø30,5 - Ø1,2 Ø35 - Ø1,37 Ø50 - Ø1,96 Ø56,5 - Ø2,2 Ø80 - Ø3,15 Ø82 - Ø3,22
Y mm-inch - - 95 - 3,74 113 - 4,44 200 - 7,87 276 - 10,86 281 - 11,06 328 - 12,9
Z mm-inch - - 42 - 1,65 46,5 - 1,83 75 - 2,95 67,5 - 2,65 114,5 - 4,5 130 - 5,11
L mm-inch - - Rp 1” Rp 1-1/4” Ø40,3 - Ø1,58 Ø60 - Ø2,36 Ø80 - Ø3,15 Ø90 - Ø3,54
W mm-inch - - 38 - 1,5 47 - 1,85 75 - 2,95 69,5 - 2,73 126 - 4,96 132 - 5,2
I (Inlet flange) mm-inch - - 67 - 2,63 78 3,07 110 - 4,33 105 - 4,13 160 - 6,3 160 - 6,3
I (Outlet flange) mm-inch - - - - 110 - 4,33 105 - 4,13 160 - 6,3 180 - 7
Flange Bores - - No. 2xØ11 No. 2xØ10,5 No. 4xØ17 No. 4xM12 No. 8xØ18 No. 8xØ18
mm-inch - - N°2x 0,43 N°2x 0,41 N°4x 0,67 N°4x 0,71 N°4x 0,71
Weight kg-lb - - 0,6 - 1,32 1 - 2,2 3,2 - 7,05 3,2 - 7,05 7,5 - 16,53 8 - 17,63
Attention: The drawing below is not suitable for all models. Please log on to our webiste for specific drawings.
www.vmcitaly.com
SERVICE KITS VMC
APPLICATION: This valve is controlled by a thermostat. The oil cooler is bypassed when it is necessary to achieve and maintain minimum
oil temperature. This process helps to protect the compressor during the starting phase in cold condition. The valve provides a proper
start up and operation of compressor unit.
INSTALLATION: The Thermostatic Valve is installed between the air-end, separator and cooler. The oil filter nipple is included in the
Thermostatic Valve (VTFT model only). VMC offers a wide range of oil-filter nipples.
REPLACEMENT: It depends on compressor applications and working conditions. Valve inspection and its replacement is recommended
after 8.000 running hours. VMC original spare parts have to be used.
www.vmcitaly.com
SERVICE KITS VMC
2701380 (71°C)
2701385 (83°C)
2701390 (55°C)
2701280 (55°C)
2701290 (71°C)
2701285 (83°C)
SERIE VTS/VTFT 45 K1
2701495 (55°C)
2701490 (71°C)
2701498 (83°C)
2701685 (63°C)
2701680 (71°C)
2701687 (83°C)
SERVICE KITS VMC
K2
2701380 (71°C)
2701385 (83°C)
2701390 (55°C)
VTDM 28 K1 2201150
K3 2700590
K2
2701380 (71°C)
2701385 (83°C)
2701390 (55°C)
VTDM 39 K1 2201250
K3 2700595
K2
2701380 (71°C)
2701385 (83°C)
2701390 (55°C)
VTD2M45 K2 220350
K3 2700595
K1
2701495 (55°C)
2701490 (71°C)
2701498 (83°C)
VTD3M50 K2 220450
K3 2700595
K1
2701495 (55°C)
2701490 (71°C)
2701498 (83°C)
NIPPLES
A T D mm B1 mm SW K3
00375 M22X1,5 M27X1,5 115 19,2 32 2700590
00376 M24X1,5 M27X1,5 195 19,8 32 2700590
00381 M39X1,5 G1 1/4 155 35,8 50 2700595
00749 M32X1,5 G1 1/4 137 28,1 50 2700595
01467 1' 3/8 16UN G1 1/4 137 28,1 50 2700595
01469 1' 12UNF M27X1,5 115 20 32 2700590
01477 M32X1,75 G1 1/4 137 28,1 50 2700595
01478 M39X1,75 G1 1/4 155 35,8 50 2700595
01479 1' 1/2 16UN G1 1/4 155 35,8 50 2700595