Turbine Drains SOP

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 6

Power from knowledge

KSK Mahanadi Power Company Ltd.


6 X 600 MW Power Plant KMPCL/OPR/TURBINE DRAIN
SYSTEM / 01
SOP FOR TURBINE DRAIN SYSTEM

Issue No: 1 Issue Date: Revision: 0 Revision Date: File no: Page 1 of 6

STANDARD OPERATING PROCEDURE

FOR

TURBINE DRAINS SYSTEM

Prepared by: Reviewed by: Approved by:


Signature: Signature: Signature:
Name: TRIVENI KUMAR Name: Name:
Designation: Asst.Manager Designation: Designation:
Power from knowledge
KSK Mahanadi Power Company Ltd.
6 X 600 MW Power Plant KMPCL/OPR/TURBINE DRAIN
SYSTEM / 01
SOP FOR TURBINE DRAIN SYSTEM

Issue No: 1 Issue Date: Revision: 0 Revision Date: File no: Page 2 of 6

STANDARD OPERATING PROCEDURE FOR TURBINE DRAINS SYSTEM


OBJECTIVE : For Smooth Operation of Turbine under low load and Abnormal
Operation Condition .
SCOPE : This SOP is applicable for Turbine Proper and Pipe drains
INTRODUCTION : The main function of drain system is used to drain the condensate
in the steam turbine proper and the piping during the unit starting, shutdown,
Operating at low load or under abnormal Operation conditions , so as to prevent
serious accidents like the steam turbine Rotor bending , the internal parts damaged
due to the steam turbine water induction

RESPONSIBILITY: Unit Control Engineer, Field Engineer and Desk Engineer.

SAFTEY PRECAUTIONS:
Ensure no permit to work is pending on regarding this system by checking with
EE/MRSE.
SAFTEY PPE’s: Ear Plugs, Safety Goggles, Hand Gloves, etc.

SPECIAL TOOLS/ EQUIPMENTS : NIL

PRECHECKS AND ACTION BY FIELD ENGINEER:

Prepared by: Reviewed by: Approved by:


Signature: Signature: Signature:
Name: TRIVENI KUMAR Name: Name:
Designation: Asst.Manager Designation: Designation:
Power from knowledge
KSK Mahanadi Power Company Ltd.
6 X 600 MW Power Plant KMPCL/OPR/TURBINE DRAIN
SYSTEM / 01
SOP FOR TURBINE DRAIN SYSTEM

Issue No: 1 Issue Date: Revision: 0 Revision Date: File no: Page 3 of 6

PRECHECKS AND ACTION BY FIELD ENGINEER


SR Description Ok Not Ok Remarks
No
1. All permits and cross permits have been returned.

2. Area is clear of any other materials.

3. Condenser under adequate vacuum

4. HP Condenser and LP Condenser Flash tank Spray


Attemperator in Service

5. All turbine proper drains Pneumatic and MIV are in Open

All MS , CRH, HRH and Gland steam supply pipe drains


6. Pneumatic and MIV are in Open

All extractions MOV and NRV drains Pneumatic and MIV are in
7. Open

8. Both TDBFP Supply MOV’s and NRV are in Closed

8. All Extractions MOV’s and NRV’s are in Closed

PRECHECKS AND ACTION BY DESK ENGINEER :

PRECHECKS AND ACTION BY DESK ENGINEER


SR No Description Ok Not Ok Remarks

1. All permits and cross permits have been returned.

2. All turbine proper drains Pneumatic and MIV are in Open

3. Condenser under adequate vacuum

Prepared by: Reviewed by: Approved by:


Signature: Signature: Signature:
Name: TRIVENI KUMAR Name: Name:
Designation: Asst.Manager Designation: Designation:
Power from knowledge
KSK Mahanadi Power Company Ltd.
6 X 600 MW Power Plant KMPCL/OPR/TURBINE DRAIN
SYSTEM / 01
SOP FOR TURBINE DRAIN SYSTEM

Issue No: 1 Issue Date: Revision: 0 Revision Date: File no: Page 4 of 6

4. All turbine proper drains Pneumatic valves are in Open

All MS , CRH, HRH and Gland steam supply pipe drains


5. Pneumatic valves are in Open

All extractions MOV and NRV drains Pneumatic valves are in


6. Open

7. Ensure all drains MIV’s are in Open

8. Both TDBFP Supply MOV’s and NRV are in Closed

9. All extraction MOV’s and NRV’s are in Closed

All turbine Proper and Pipe Drain Pneumatic valves Interlocks


10. are in Service

OPERATING PROCEDURE -
RESPONSIBILITY
Sr.
Description SIC / DE FE EE
No.
UCE
PRE- START CHECKS :-
1. All permits and cross permits have been returned.

2. The Air supply Pressure of Pneumatic drain valves is 0.45 – 0.8 MPa (g)

3. Before the unit starting Conforming that the condenser operating


normally and certain vacuum as been established

4. The drain flash tank is equipped with spray attemperator on HP and LP


condenser side ,so as to maintain the temperature below 150 deg C and
Pressure less than 0.14 MPa(g)

5. All Turbine Proper and Pipes Pneumatic and MIV’s are in Open

Prepared by: Reviewed by: Approved by:


Signature: Signature: Signature:
Name: TRIVENI KUMAR Name: Name:
Designation: Asst.Manager Designation: Designation:
Power from knowledge
KSK Mahanadi Power Company Ltd.
6 X 600 MW Power Plant KMPCL/OPR/TURBINE DRAIN
SYSTEM / 01
SOP FOR TURBINE DRAIN SYSTEM

Issue No: 1 Issue Date: Revision: 0 Revision Date: File no: Page 5 of 6

6. All Extractions MOV’s and NRV’s are in Closed

UNIT START UP :-
1. DEH Control system will Open the pneumatic drain valves on each drain
branch automatically

2. Load is Up to 20% rated load , Automatically Close the pneumatic drain


valves on the HP and IP section

3. Load is Up to 30% rated load , Automatically Close the pneumatic drain


valves on the LP section

4. The automatic close through interlock is out of service , Pneumatic


drains are Closed manually

5. HP & LP bypass , CRH ,HRH,TDBFP drain line Provided with drain pot
with water level control for Automatically Open when level is high

SHUTDOWN SEQUENCE :-
1. Load is reduced up to 30% rated load , Automatically Open the
pneumatic drain valves on the LP section

2. Load is reduced Up to 20% rated load , Automatically Open the


pneumatic drain valves on the HP and IP section

3 The automatic Open through interlock is out of service , Pneumatic


drains are Open manually

EMERGENCY SHUT DOWN :-


1. Emergency trip occurs , all Pneumatic drains of turbine Proper and
Pipes line Automatically open

2. All Extractions MOV’s should be Closed

3. Both TDBFP MOV’s should be closed

Prepared by: Reviewed by: Approved by:


Signature: Signature: Signature:
Name: TRIVENI KUMAR Name: Name:
Designation: Asst.Manager Designation: Designation:
Power from knowledge
KSK Mahanadi Power Company Ltd.
6 X 600 MW Power Plant KMPCL/OPR/TURBINE DRAIN
SYSTEM / 01
SOP FOR TURBINE DRAIN SYSTEM

Issue No: 1 Issue Date: Revision: 0 Revision Date: File no: Page 6 of 6

4. HP and LP condenser drain flash tank spray attemperator should be


taken in service

5. Condenser operating under normally certain vacuum

ABRIVIATIONS / NOTATIONS :-

o SOP : Standard Operating Procedure


o SIC : Shift In Charge
o UCE : Unit Control Engineer
o DE : Desk Engineer
o FE : Field Engineer
o DCS : Distributed Control System
o EE : Electrical Shift Engineer

 References : Turbine Proper and Pipes Drain “O & M” Manual.

Prepared by: Reviewed by: Approved by:


Signature: Signature: Signature:
Name: TRIVENI KUMAR Name: Name:
Designation: Asst.Manager Designation: Designation: