ETABS 2016 Concrete Frame Design: ETABS 2016 16.0.3 Gilang Ramadhan Andaluna License # 1S5LLY67BDQYHLR

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

ETABS 2016 16.0.

3 Gilang Ramadhan Andaluna License #*1S5LLY67BDQYHLR

ETABS 2016 Concrete Frame Design


IS 456:2000 Column Section Design

Column Element Details Type: Ductile Frame (Summary)


Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
Lantai 1 C8 144 K1 700 x 700 DCon11 0 4000 0,718

Section Properties
b (mm) h (mm) dc (mm) Cover (Torsion) (mm)
700 700 71 40

Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
25742,96 30 1 300 240

Design Code Parameters


ɣC ɣS
1,5 1,15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar % Capacity Ratio
kN kN-m kN-m kN-m kN-m % Unitless
694,9362 0 20,8018 20,8018 20,8018 1,24 0,1

Axial Force and Biaxial Moment Factors


K Factor Length Initial Moment Additional Moment Minimum Moment
Unitless mm kN-m kN-m kN-m
Major Bend(M3) 1 3300 0 0 20,8018
Minor Bend(M2) 1 3300 0 0 20,8018

Shear Design for Vu2 , Vu3


Shear Vu Shear Vc Shear Vs Shear Vp Rebar Asv /s
kN kN kN kN mm²/m
Major, Vu2 88,1124 277,606 176,1208 88,1124 1341,67
Minor, Vu3 88,1124 277,606 176,1208 88,1124 1341,67

Joint Shear Check/Design


Joint Shear Shear Shear Shear Joint Shear
Force VTop Vu,Tot Vc Area Ratio
kN kN kN kN cm² Unitless
Major Shear, Vu2 N/A N/A N/A N/A N/A N/A
Minor Shear, Vu3 N/A N/A N/A N/A N/A N/A

RUN 13.EDB Page 1 of 2 01/01/2017


ETABS 2016 16.0.3 Gilang Ramadhan Andaluna License #*1S5LLY67BDQYHLR

(1.1) Beam/Column Capacity Ratio


Major Ratio Minor Ratio
N/A N/A

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag Asc Puz Pb Pu k
cm² cm² kN kN kN Unitless
4900 60,8 7983,36 4061,67 694,9362 1

Additional Moment (IS 39.7.1)


Consider Length Section KL/Depth KL/Depth KL/Depth Ma
Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 0,825 700 4,714 12 No 0
Minor Bending (M2 ) Yes 0,825 700 4,714 12 No 0

Notes:

N/A: Not Applicable

N/C: Not Calculated

N/N: Not Needed

RUN 13.EDB Page 2 of 2 01/01/2017