[LM 0218] FEBRUARY 2018 Sub.

Code: 1836

B.Sc. RADIOLOGY IMAGING TECHNOLOGY


(New Syllabus 2014-2015)
THIRD YEAR
PAPER I – EQUIPMENTS OF MODERN IMAGING MODALITIES

Q.P. Code: 801836


Time: Three Hours Maximum: 100 Marks
Answer all questions
I. Elaborate on: (3 x 10 = 30)

1. Explain in detail the basic imaging concepts in MR imaging.


2. Describe about the various flat panel detectors in X-ray imaging.
3. Describe in detail the various parts of mammography equipment.

II. Write notes on: (8 x 5 = 40)

1. Gradient echo sequence.


2. CR reader.
3. Types of magnets in MRI.
4. Multi detector CT.
5. Ultrasound transducer.
6. 3 Artefacts in CT.
7. Effect of contrast agents used in MRI.
8. Factors affecting image quality in CT.

III. Short answers on: (10 x 3 = 30)

1. Linear attenuation co-efficient.


2. TR and TE.
3. T1w imaging.
4. Zebra artifact in MRI: cause and remedy.
5. Phased array transducer.
6. Curie temperature.
7. Precessional frequency.
8. Resonance.
9. Tomography.
10. Filtration in X-ray imaging.

*********
[LN 0818] AUGUST 2018 Sub. Code: 1836

B.Sc. RADIOLOGY IMAGING TECHNOLOGY


(New Syllabus 2014-2015)
THIRD YEAR
PAPER I – EQUIPMENTS OF MODERN IMAGING MODALITIES

Q.P. Code: 801836


Time: Three Hours Maximum: 100 Marks
Answer all questions
I. Elaborate on: (3 x 10 = 30)

1. Discuss in detail the various generations of the CT scanners. Mention the


advantages of the multislice CT scanner over conventional CT.
2. Describe in detail the various parts of a mammography equipment.
3. Describe about the different flat panel detectors used in X-ray imaging.

II. Write notes on: (8 x 5 = 40)

1. Explain the principle of PET-CT.


2. Explain Fraunhoffer Zone in Ultrasound.
3. Spin echo sequence.
4. Superconductive magnet.
5. Factors affecting image quality in computed radiography.
6. Larmor frequency in MRI.
7. Factors affecting image quality in MRI.
8. Nuclear imaging in myocardial perfusion.

III. Short answers on: (10 x 3 = 30)

1. Piezo-electric effect.
2. Flip angle.
3. Ring artifacts.
4. CT number.
5. What is wrap around artifact in MRI?
6. Scintillation detector.
7. B mode in ultrasound.
8. T2w imaging.
9. What is the basic principle of DSA?
10. What are the uses of PACS?

*********
[LO 0219] FEBRUARY 2019 Sub. Code: 1836

B.Sc. RADIOLOGY IMAGING TECHNOLOGY


(New Syllabus 2014-2015)
THIRD YEAR
PAPER I – EQUIPMENTS OF MODERN IMAGING MODALITIES

Q.P. Code: 801836


Time: Three Hours Maximum: 100 Marks
Answer all questions
I. Elaborate on: (3 x 10 = 30)

1. Describe an Ultrasound transducer with suitable diagram.


Enumerate the various types of Ultrasound transducers.
2. Describe in detail the function of a digital subtraction angiography machine.
3. Discuss in detail the principle and working of a gamma camera.

II. Write notes on: (8 x 5 = 40)

1. Enumerate the various interactions of Ultrasound waves with matter.


2. Artifacts encountered during MR imaging.
3. What is radio frequency pulse? Add a note on chemical shift imaging.
4. CR image reader.
5. Explain in detail about indirect flat panel detectors.
6. Explain CT windowing
7. Explain Xenon gas detectors in CT.
8. Discuss about two radio isotopes used as a therapeutic agent in nuclear medicine.

III. Short answers on: (10 x 3 = 30)

1. What is FID in MRI?


2. Define pixel in CT.
3. Various filters used in X-ray imaging.
4. Compare conventional mammography with digital mammography.
5. Role of Ultrasound in obstetrics.
6. MR angiography techniques.
7. Define Pitch in CT.
8. CR image plate phosphor.
9. Tesla.
10. Quadrature body coil. 

*********