0% found this document useful (0 votes)
168 views112 pages

Fire Solutions Catalogue 2018

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 112

Fire and voice alarm systems

Product catalogue

Complete fire systems


for the protection of
life and property
We make what matters work.*

* Every day, people depend on things like technology,


transportation, energy and infrastructure to keep their
daily lives on track. But without power, none of it would be
possible. That’s why companies around the world turn to
Eaton. We’re dedicated to improving people’s lives and the
environment with innovative technologies that help manage
power more safely, reliably and sustainably. To meet
today’s challenges, and tomorrow’s. Because this is what
really matters. And we’re here to make sure it works.

To learn more go to: Eaton.com/whatmatters

We make what matters work.


Introduction
Section Name

4 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Introduction
Distinctive capabilities

Excellence and innovation in


fire safety solutions.
When it comes to protecting life and property there’s no room to compromise.
You need a partner that can support you with tried and tested products, global
capabilities and local delivery.
Eaton is a leading manufacturer and global supplier of high quality fire systems.
With our ability to provide complete systems, not just components, you can
be confident in the knowledge that all of our products have been specifically
designed and tested to ensure that they are all fully compatible to form a
reliable and compliant fire detection and alarm system.
Our large multi-disciplined research and development team is responsible for
the integration of the latest technology into the full range of fire products,
ensuring that our products are designed to the latest fire industry standards
and manufactured to the highest levels of quality. The many innovative,
new and improved products featured in this catalogue demonstrate our
commitment to staying at the leading edge of technological development for
fire detection and alarm equipment.

Our core values and aims are:


• Investment in people
• To partner with our customers to develop open, long term relationships
• To have an unpretentious, straightforward and honest approach to
business
• The continued investment in research and development
• Investment in manufacturing facilities to ensure they remain world class
• To produce products that are in full compliance with standards
• To operate in an environmentally friendly way - in the products we design
and the facilities in which we make them
• To have high ethical standards

Our solutions and services are recognised by a wide range of accreditation


bodies, so you can count on products that comply with national and industry
standards, while receiving full support, from initial system design to monitoring
and service.

ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO
S

A
S

R
LO D

SIGNALING

4AC5
FIRE ALARM
EQUIPMENT

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 5


Introduction
Distinctive capabilities

Ankara Esenboğa International Airport


Ankara, Turkey

St Pancras Station
London, UK

Doncaster Cultural and Civic Quarter


Doncaster, UK

6 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Introduction
Distinctive capabilities

Manufacturing fire solutions is just


one small element of what we do.
Services
We believe that ownership of fire detection systems extends beyond the
initial purchase of the products themselves. We therefore offer customers a
wide range of services to ensure that their installations not only meet basic
operational and safety requirements on day one, but will continue to do so
throughout their lifetime.
From training and support on how to select products for a specific application
through to the provision of routine on-site testing and maintenance. You can be
sure that Eaton is ready to support you, whatever your needs.

Major projects
Design and installation of a fire detection system can often be a complex
process, with each project often bringing its own challenges in making sure the
system is compliant, reliable and easy to operate. Our team of engineers will
partner with your project management team using our expertise to meet the
specific requirements of your project.
Eaton has a great deal of experience handling major projects across the
globe. We can help not just with the product and technical support but also by
providing guidance and advice to specifiers and project management teams on
topics such as standards and regulations.
We are BAFE SP203 certified for design, commissioning and maintenance of
fire detection systems, giving our customers the peace of mind they need that
our systems conform with all necessary safety requirements.

Technical support
Our dedicated technical support team are able to offer customers around the
world advice and guidance on a wide variety of technical matters via telephone
or email. In the vast majority of cases, a process of systematic questioning
enables the team to diagnose the challenge and advise the customer on the
appropriate solution.
Sometimes more detailed troubleshooting and analysis methods may be
used to determine the actual requirements and the best way of resolving it.
If necessary, the technical support team will also call on the knowledge and
expertise of Eaton’s product management, R&D and design departments to
help resolve the customer’s issue.
In addition, the technical support team can provide customers with assistance
on product information, installation and operating instructions, and the
legislative requirements of your fire detection systems.

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 7


Introduction
Contents

Mariner's Quay Apartment Complex


Newport

8 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Introduction
Contents

Contents
1. Introduction
An introduction to fire systems 10
Conventional and two-wire systems 12
Addressable systems 13
Emergency voice communication systems 14
UL listed fire systems 15
Voice alarm systems 15

2. Intelligent addressable systems


Fire panels and repeater panels 18
Addressable devices 24

3. UL intelligent addressable systems


Fire panels and repeater panels 48
UL listed devices 50

4. Two-wire and conventional systems


Two-wire control panel 62
Two-wire devices 66
Fire panels and repeater panels 68
Conventional devices 74

5. Emergency voice communications


VoCALL control panels 90
VoCALL devices 96
Emergency assist alarm 98

6. Appendix
Part code lookup 102
Contact details 111

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 9


Introduction
An introduction to fire systems

An introduction to fire systems


Eaton manufacture and supply a range of different
types of fire systems, meaning we can provide a
high quality fire solution whatever your need is.
There are a vast array of fire detection systems
and devices on the market today, ranging from
the relatively simple to the most technically
sophisticated. Modern automatic fire detection
systems are available in two types, conventional
and addressable - which, broadly speaking, tend
to be used in smaller and larger installations
respectively. For more detail you can read our fire
systems guide over the next few pages.

The basics of fire detection


A control panel is the hub of the detection system.
All the devices which are part of the fire detection
system are connected to this central panel which
processes the signals received from the input
devices and gives out signals to the output devices.
Input devices such as detectors measure signals of
combustion and communicate with panels, which
in turn trigger output devices such as an audible or
visual alarm device. Fire alarm panels can be further
sub segmented into addressable or conventional
panels.
There are various types of fire detection systems
each suited to different applications or building
types. A fire detection system can vary significantly
in both complexity and price, from a single panel
with a detector and sounder in a small commercial
property to a complex intelligent addressable
system in a multi-occupancy building.
A fire detection system can comprise of detection
devices, notification devices and manual callpoints.
The size of the building determines the number
of detectors that would be required. The system
works via the control panel receiving signals from
the detection devices and then sending transmitting
signals to the notification devices.

10 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April


January
2018
2018
Introduction
An introduction to fire systems

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 11


Introduction
Conventional fire systems

Conventional systems (p68-88) Two-wire systems (p62-67)


The philosophy of a conventional system revolves around Two-wire systems are based on standard conventional system
dividing the building into a number of areas called zones. The technology, but it also incorporates additional functionality to
detectors and call points within each zone are then wired on a enable the callpoints, detectors and sounders for each separate
dedicated separate circuit. zone to be wired on a single common circuit.

In the event of a detector or call point being triggered, the By combining both the detection and the alarm annunciation
panel is able to identify which circuit contains the triggered wiring into a single circuit, considerable savings in installation
device and thereby indicate which zone the fire alarm has time and cabling can be achieved.
come from. The indicated zone can then be manually searched
to locate the triggered device. Eaton's BiWire Flexi panel combines two technologies so that
it can be configured to allow either two-wire or conventional
With this type of functionality a conventional system is best devices to work on a zone. This flexibility means it can be easily
used in smaller builds where it wouldn’t be difficult to locate incorporated into system extensions or used as part of a
the triggered device in a given zone. new system.

Zone 1 Zone 2

Zone 3 Zone 4

Typical conventional system architecture Typical two-wire system architecture

Example conventional system layout Example two-wire system layout

12 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Introduction
Addressable fire systems

Addressable systems (p17-45)


Intelligent addressable systems overcome the limitations of
conventional systems as each fire detector or call point is
electronically coded with a unique identification or 'address'
which is programmed into the device during installation.

By using each devices' unique address, the control panel


is able to conduct two way communication with any of the
addressable devices connected to the system.

Under normal conditions the control panel continuously


interrogates each device in sequence and analyses the reply to
determine the status of each detector or call point. The panel
checks whether each device is functioning correctly and also
the amount of smoke or heat that the device is
currently sensing.

With the functionality of being able to pinpoint exactly which


device is being triggered in an alarm or for a fault, addressable
systems are perfect for mid to large size builds with multiple
rooms and floors.

Zone 1 Zone 2

15 16 1 2

14 3

13 4

12 5

11 6

10 9 8 7

Zone 3 Zone 4

Typical addressable system architecture

Example addressable system layout

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 13


Introduction
Emergency voice communication systems

Emergency voice communication systems (EVCS) (p91-99)


What is disabled refuge? building. Fire telephones can also be used for fire
wardens to call the control point during fire drills
A disabled refuge is a relatively safe area within and primary evacuation phases before the fire
a building or exit staircase for mobility impaired services arrive and assume control.
occupants, allowing building management and
emergency services to safely assist these people What is a disabled refuge EVC system?
from the building.
An EVC System (Emergency Voice Communication
Mobility impairment is defined as not being able to System) is a fixed, monitored and maintained,
walk 200m continuously without aid, and includes bi-directional, full duplex voice communication
arthritis sufferers, people with leg and back injuries system. These systems are designed to assist the
and women over 6 months term pregnancy. orderly evacuation of disabled or mobility impaired
people and enhance fire fighters' communication
What is a fire telephone? during emergencies.
Fire telephones are hardwired full duplex A disabled refuge system is not just for use during
communications systems with monitoring and a fire and must be available at all times. Building
battery backup and are required in buildings over regulations insist all new non-domestic buildings
four storeys in many countries in the world (in the with more than one storey provide ‘refuge’ areas
UK this is governed by BS9999, 2017). These are – relatively safe places where people who cannot
provided as a backup to traditional fireman’s radio easily use fire escapes and evacuation lifts, can call
systems, which can fail to operate in many high rise for assistance and wait until help arrives. Simple,
environments due to the large amount of steel in effective two-way communication (refuge system)
the building, and the “corona” effect of fire on radio in these areas is essential, firstly to assist rescue
broadcasts. teams in determining where assistance is required
and secondly to reassure people help is on the way.
Fire telephones are also required in fire fighting
lift lobbies when these lifts are provided within a

14 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Introduction
UL listed fire systems and voice alarm systems

UL listed fire systems (p48-59)


Underwriters Laboratories Inc. (UL) is an in South East Asia and several major projects in
independent product safety certification the Middle East including the prestigious Riyadh
organisation, established in 1894, to develop Financial District in the Kingdom of Saudi Arabia.
standards and test procedures for products,
The Eaton UL range is designed to provide a
materials, components, assemblies, tools and
solution for all sizes of project, from the simple
equipment. Chiefly dealing with product safety
small stand alone system to the large multi
it also evaluates and certifies the efficiency of
panel networked system with PA/VA and BMS
a company’s business processes through its
integration.
magnificent system registration programs.
Since the launch of our UL Listed fire product SIGNALING
range, several prestigious projects worldwide have
been supplied including Hyatt Resort and Spa,
Shangri-la at the Fort and Times Square projects
4AC5
FIRE ALARM
EQUIPMENT

Public address/voice alarm systems


Under BS5839 Pt.8 2013, voice alarm (VA) systems are recommended for all public buildings and multi-
storey buildings over four floors. VA systems are the quickest way to evacuate the public and staff
from a building.
Following fire detection, automated messages control the flow of people in stair wells and corridors
allowing an orderly evacuation without panic. These messages are supplemented by spoken messages
from the fire service or management suite confirming the validity and need to leave the building. This
positive confirmation speeds evacuation and avoids the “false alarm” mentality reducing the risk of death
from fire.

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 15


16 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018
Intelligent addressable systems
Contents

Contents
Intelligent addressable systems

Panels

CF2000 addressable panel 18 CF1100VDS addressable panel 20 CF3000 addressable panel 22

Devices

Detectors and indicators 24 Bases 26 Callpoints 28

Wall sounders and VADs 29 Beam detector 33 Duct probe 33

Interfaces 34 Micro interfaces 38 Networking interfaces 40

Ancillaries 42 Software 44 Test equipment 45

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 17


Intelligent addressable systems
CF2000GCPD

CF2000GCPD
Intelligent addressable control panel

“The CF2000GCPD serves


as the optimum solution for
buildings requiring smaller
addressable systems.”

The Eaton CF2000GCPD is an entry level intelligent Benefits


addressable control panel which can be configured • Configurable as a 1 or 2 loop panel
for either 1 or 2 loop operation, and is certified to
• Up to 200 addresses per loop (up to 60
EN54 parts 2 & 4.
sounders/beacons and up to 20 I/Os, subject
The panel has a graphic display, providing a
to loop loading calculations)
simple menu driven end user interface. With the
CF2000GCPD’s ability to support Eaton cause and • Soft addressing
effect programming and a range of user controllable • Menu-driven graphic screen
functions it makes the panel suitable for a varied • Multi-language selection capability
range of projects from small warehouses to small/ • Integral battery and power supply
medium office developments as well as many small • 2x7Ah batteries included
industrial applications.
• Easy to operate end user controls
As with all Eaton intelligent addressable panels, the
CF2000GCPD uses "spur tolerant" soft addressing • Full system integrity with Eaton developed
to minimise installation time and remove the protocol
potential for errors often associated with many • Core range of compatible devices
forms of manual addressing. • 4 sounder circuits
• Monitored for open and short circuit (max
3.0A combined) ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO

18 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Intelligent addressable systems
CF2000GCPD

Dimensions Compatible repeater panels

W The CF2000GCPD has a standard repeater panel


available. Ideal for larger sites, the repeater allows you to
display the system information from multiple locations.

24V dc output
D

H (mm) W (mm) D (mm) Features CF3000PRG


400 320 170 Active or passive option 
Integral battery and power supply 
Supervisor and engineer modes through
Catalogue numbers code access

Description Code
Intelligent addressable 2 loop control panel CF2000GCPD
Standard repeater panel CF3000PRG
Fire alarm system log book MFALOG

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 19


Intelligent addressable systems
CF1100VDS

CF1100VDS
Intelligent addressable control panel

“The simplicity of
operation, powerful
cause and effect
programming capability
and competitive pricing
make the system
suitable for a wide
range of small to
medium sized projects.”

The CF11000VDS is a high specification addressable Benefits


panel for medium sized builds that is equipped with • Soft addressing
a versatile touch screen user interface. It is available
• Large versatile touch screen user interface
as a 1 (CF1100VDS) or 2 (CF1200VDS) loop panel.
• Multi-language selection capability
The powerful cause and effect programming • Integral battery and power supply
capability and competitive pricing make the system • 2x7Ah batteries included
suitable for a wide range of small to medium sized • Flexible distributed network capability
projects. The panels can operate as standalone or as
• Full range of compatible devices
part of a network with our other addressable panels
(additional network card required). • Flexible and easy to design, system cause
and effect using site installer software
• Compatible with our addressable repeaters
CF1100VDS CF1200VDS* (see p21)
No. of loops 1* 2*
Addresses per loop 200** 200**
No. of conventional sounder circuits 2*** 2***
* No zonal LEDs
** Up to 60 sounders/beacons and up to 20 I/Os
***Monitored for open and short circuit (max 1.5A combined)

20 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015


Approved product
Intelligent addressable systems
CF1100VDS

Dimensions
D W

H (mm) W (mm) D1 (mm)


Panel 375 357 95
Cutout 345 325 50

CF1100VDS pictured with a range of compatible devices

Catalogue numbers
Description Code
1 loop control panel CF1100VDS
2 loop control panel CF1200VDS
Add to end of product code if network card required NC
Add to end of product code if dual redundancy NCDR
network card required
Network kit (for retro fit) DF61NETKIT
Passive repeater panel CF3000PRG
Touch-screen repeater panel CTPR3000
Fire routing equipment PCB ZPCB2187FRE
Fire alarm system log book MFALOG

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 21


Intelligent addressable systems
CF3000

CF3000
Intelligent addressable control panel

“The large capacity,


ability to support
complex cause and
effect programming
and wide range of
user controllable
functions make the
system suitable for
a diverse range of
projects”

The CF3000 series are high specification intelligent Benefits


addressable control panels, which are fully certified • Soft addressing
to EN54 parts 2 and 4.
• Large versatile touch screen user interface
Each panel is networkable with up to 126 other • Multi-language selection capability
Eaton addressable control panels, only requiring • Integral printer (optional)
the addition of one of our network cards for this • Integral battery and power supply
functionality. Using our latest software, the panels • 2x 12Ah batteries included
can be set up for smoke management protocols,
• Extended battery option allows for 72 hours
when used in conjunction with FC6 or FC18
standby (subject to loop loading calculations)
fan controller units, and the new MCOM-FC
interface module. • Flexible distributed network capability
CF30002G CF30004G • Full range of compatible devices
No. of Loops 2 4 • Easy to design system cause and effect using
Addresses per Loop 200* 200* site installer software
No. of Conventional 4** 4** • Additional functionality through FRE & FPE
Sounder Circuits
(Fire Routing Equipment & Fire Protection
* Up to 60 sounders/beacons and up to 20 I/Os
**Monitored for open and short circuit (max 1.5A combined) Equipment) which are both monitored outputs
ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO

22 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Intelligent addressable systems
CF3000

Class change functionality Compatible repeater panels


Our CF3000 panel has a variety of easy to use
The CF3000 has both a passive and a touchscreen
additional software options on top of the
repeater panel available. Ideal for larger sites, the
standard class change facility; this provides repeater allows you to display the system information at
benefits for a number of regions. Contact us for multiple locations.
more information.

Features CF3000PRG CTPR3000


Active or passive option  
No programming required * 
Programmable input  
Integral battery and power  
supply
Supervisor and engineer  
modes through code access
Fire and fault volt free  
programmable relays
Adjustable volume from panel  
*Programming not required on network version.

Dimensions Catalogue numbers


Description Code
D2
2 loop control panel CF30002G
W
4 loop control panel CF30004G
2 loop control panel, integral printer CF30002GP
4 loop control panel, integral printer CF30004GP
Add to end of product code if network card required NC
Add to end of product code if loop card required LC
H
Network kit (for retro fit) DF6000NETKIT
Printer kit (for retro fit) CF3000PKIT
Hinged protective cover kit CF3000COV
Passive repeater panel CF3000PRG
Touch-screen repeater panel CTPR3000
Fire alarm system log book MFALOG
D1

H (mm) W (mm) D1 (mm) D2 (mm)


Standard 397 497 55 125

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 23


Intelligent addressable systems
Devices - detectors

Detectors
Our addressable range has multiple options for intelligent addressable
detectors. All detectors are designed for optimum functionality in mid-large
sized builds. They are all soft addressed and have integral short circuit isolators.
We also offer a loop connected remote indicator, designed to offer discreet
remote indication and an ability to monitor multiple detectors. This helps to
minimise wiring requirements.

Optical smoke detector Photo-thermal detector Heat detector


CAP320 CAPT340* CAH330

Typical applications: Typical applications: Typical applications: *The CAPT340 has day/
night modes available,
Suitable for most applications. Responds quickly to fast clean Environments where the ambient programmeable from the site
burning fires. conditions might cause false installer software. The day
Fastest response to slow alarms with smoke detectors.
burning or smouldering fires Maintains the advantage of mode uses the heat aspect of
which give rise to large visible optical detectors when detecting Examples include areas with high the detector for areas which
smoke particles. smouldering fires. levels of dust or fumes. may have smoky environments
during, for example working
The CAH330 can operate in 3 hours. The night mode uses a
modes: rate of rise, fixed heat combination of A2S and smoke
77°C and fixed heat 90°C. detection. If not programmed,
the detector defaults to dual
These modes are set by mode.
the panel.

Dimensions Performance
Dia
Feature CAP320 CAPT340 CAH330 CAH330 CAH330

Mode Optical Photo- Rate of rise Fixed heat Fixed heat


thermal 77°C 90°C

Area 100m2 100m2 50m2 50m2 50m2


coverage*

D1 Heat class N/A A2S A2R BS CS


D2
Alarm N/A 60 ˚C 60 ˚C 77 ˚C 92 ˚C
temperature

*(subject to local standards)

Diameter (mm) Depth (mm) Depth (mm) Catalogue numbers


Description (incl base) (excl base) (incl base) Description Code
Optical 104 33 45 Optical smoke detector - CAP320 CAP320
Photo-thermal 104 43 55
Photo-thermal detector - CAPT340 CAPT340
Heat 104 43 55
Multi-mode heat detector - CAH330 CAH330

ERTI
N C F
IO I
C
T

AT
PREVEN

24 LPCB
ION BO

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Intelligent addressable systems
Devices - indicators

Indicators
Our indicators are designed as additional indication devices when detectors
have been triggered. These products are designed to be used as indicators only,
and not visual alarm devices (see p26 and 29 for EN54-23 certified VADs).

Addressable remote Standard remote Staff warning device


indicator indicator CAB382
MRIAD CIR301

Typical applications: Typical applications: Typical applications:


Monitoring multiple detectors The CIR301 can only be As this product does not meet
within a specific area. connected to one detector and is EN54-23 requirements as a
powered by this detector. beacon we recommend it as an
Must be configured through site internal warning device in
installer. The remote indicator can There is a weather resistant offices, schools or manned
be programmed as a sounder. version also available. (Not IP65). reception areas.
Remote indicator lens detail

Dimensions Catalogue numbers


D

Description Code

Loop connected remote indicator MRIAD

Standard remote indicator CIR301


H
D
Weather resistant standard remote indicator CIR301WP

CAB382 Staff warning device CAB382

W
Dia

Staff warning device Remote indicators

Diameter
Description (mm) Depth (mm)
Staff warning device 101 33

Height
Description (mm) Width (mm) Depth (mm)
Remote indicators 87 87 30

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 25


Intelligent addressable systems
Accessories - bases

Bases
We stock a variety of bases, providing a wide functionality for different
situations. The standard base (CAB300) provides a foundation for our
addressable detectors. The range of bases also includes capability for additional
sounder and sounder beacon operation. Both our sounder base (CAS380) and
VAD sounder beacon base (CASBB394) can be used as standalone devices
when fitted with our cover plate (CASC).

Standard base Sounder base Sounder beacon base Sounder base


CAB300 CAS380 CASBB394 (CASBB384) with cover
CAS380 + CASC

0.5Hz
FLASH

Typical applications: Typical applications: Typical applications: Typical applications:


General use product, Areas of limited extent, where The CASBB394 is an EN 54-23 Optional cover plate can be used
recommended for use in all lower output volume is required certified Visual Alarm Device to enable the sounder to operate
environments (VAD) sounder beacon base. as a dedicated discreet stand
Areas with limited cable space alone device
It is compatible with the Eaton
Concrete ceilings, to save cabling range of intelligent addressable
detectors and can also be used as
a dedicated discreet standalone
device.

CASBB384
The CASBB384 sounder beacon
base is also available for indication
purposes, where EN 54-23 is not
a requirement.

Features
CAB300 CAS380 CASBB384 CASBB394
First fix base    

Loop integrity switch    


Multiple cable entry points    

Selectable tones    

VAD sounder beacon base shown with optical detector

ERTI
N C F
IO I
C
T

AT
PREVEN

26 LPCB
ION BO

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Intelligent addressable systems
Accessories - bases

Performance
CAS380 CASBB384 CASBB394

Sound output

Low volume 84dB at < 4mA 83dB @ <6.6mA 83dB at < 8.6mA

Medium volume 92dB at < 8mA 90dB @ <8mA 90dB at < 10mA

High volume 95dB at < 12mA 93dB @ <9mA 93dB at < 11mA

Flash rate n/a 1 Hz flash 0.5 Hz flash*

*Polar dispersion infromation available on datasheet

Dimensions
Dia

D D
D

Dia Dia

Standard base Sounder base Sounder beacon


base

Description Diameter (mm) Depth (mm)


Standard base 104 22
Sounder base 102 40
Sounder beacon base 115 44

Catalogue numbers

Description Code

Standard base CAB300

Sounder base CAS380

VAD sounder beacon base CASBB394

Sounder beacon base CASBB384

Cover plate (pack of 5) CASC

Australian sounder base* CAS380AU*

Base shroud BAR3000

* Only for Australian market

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 27


Intelligent addressable systems
Devices - callpoints

Callpoints
Two versions of the intelligent addressable callpoint are available, the surface/
flush mounted CBG370S or the weatherproof CBG370WP. Both have an
integral short circuit isolator and are very simple to install. The callpoints are
packaged with 2 frangible glass elements and test key, with a comprehensive
range of further accessories available.

Surface/flush mounted Weatherproof callpoint Dimensions


callpoint CBG370WP
CBG370S W

Typical applications: Typical applications: Description H (mm) W (mm) D (mm)


General use product, suitable for Builds requiring a callpoint in Surface mounted 87 87 36
use in most indoor applications. harsh conditions. For example,
Flush mounted 87 87 57
outside or in a wash down area.
Weatherproof 87 87 59

Features Further accessories:


CBG370S CBG370WP
Fast fit clip  
High Visibility LED  
Heavy duty terminals  
Ingress protection IP24 IP65

Catalogue numbers Callpoint shown with protective


hinged cover
Description Code

Surface/flush callpoint CBG370S

Weatherproof callpoint CBG370WP

CXPC Protective hinged cover (pack of 10) CXPC

MBGBEZ Recessing bezels (pack of 10) MBGBEZ

MBGREKIT Resettable element kit (pack MBGREKIT


of 10)

UBSG Spare break glasses (pack of 5) UBSG

MFBGKEY3 Callpoint keys (pack of 10) MFBGKEY3 Callpoint recessing bezel

ERTI
N C F
IO I
C
T

AT
PREVEN

28 LPCB
ION BO

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Intelligent addressable systems
Devices - wall sounders

Wall sounders and VADs


There are also two versions of our intelligent addressable wall sounder, the internal (CAS381) and the
weatherproof (CAS381WP). Their highly efficient design offers excellent sound output levels despite the
low current consumption. They both contain an integral short circuit isolator and have multiple tones and
volume levels which can be controlled from the panel globally, or individually via site installer.
We also offer a new open class Visual Alarm Device (CASB393), combining the high output sound of the
wall sounders with a stronger LED to meet the EN54-23 VADs requirements. The open class functionality
allows the VADs to be installed in open areas such as warehouses or airport terminals.

Wall sounder VAD wall Wall sounder Dimensions


CAS381/ sounder beacon beacon
CAS381WP CASB393/ CASB383/ D
w

CASB393WP CASB383-WP D

H H

0.5Hz
FLASH

Internal wall sounder / Weatherproof wall


Typical Typical Typical sounder beacon sounder/sounder beacon
applications: applications: applications:
Both an indoor and The CASB393 is an The CASBB383 wall Description H (mm) W (mm) D (mm)
weatherproof variant of the addressable open class sounder beacon is also
Wall sounder 105 105 95
wall sounder are available, VAD suitable for all available for indication
allowing for consistent markets where purposes, where WP wall sounder 108 108 103
performance for any EN 54-23 VADs are EN 54-23 is not VAD sounder beacon 108 108 96
application where a wall now a requirement. a requirement.
sounder is required. White flash only. Red flash only. WP VAD sounder beacon 110 110 105

CAS381/ CASB383/ CASB393/ CAS381B/ CAS381AU/ CASBB384-B


Tones CAS381WP CASB383-WP CASB393WP CAS381WPB CAS381AU-WP
Continuous      
Two tone @ 1Hz cycle      
Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap      
Pulsed 1Hz (Virtual Tone)      
Pulsed sweep ISO8201 3x500ms 800-970Hz 1½ Sec Gap      
Bell tone      

Sound output Catalogue numbers


CAS381/ CASB383/ CASB393/ Description Code
CAS381WP CASB383-WP CASB393WP Internal wall sounder CAS381
Low volume 87dB at < 2mA 92dB at < 6.5mA 87dB at < 8.6mA Weatherproof wall sounder CAS381WP
VAD wall sounder beacon CASB393
Medium volume 93dB at < 3mA 97dB at < 7.5mA 93dB at < 10mA
Weatherproof VAD wall sounder beacon CASB393WP
High volume 100dB at < 6mA 100dB at < 8.5mA 100dB at < 11mA Internal wall sounder bell tone CAS381B
Weatherproof wall sounder bell tone CAS381WPB
Flash rate n/a 0.5Hz Flash
Australian internal wall sounder CAS381AU
Australian weatherproof wall sounder CAS381AU-WP
Wall sounder beacon CASB383
Wall sounder beacon weatherproof CASB383-WP
Sounder beacon base bell tone CASBB384-B
VAD wall sounder beacon bell tone CASB393B
Weatherproof VAD wall sounder beacon bell tone CASB393WPB
ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 29


S

A
S

R
LO D
Intelligent addressable systems
Devices - wall sounders

Wall sounder VAD Dimensions


CASB493/CASB493WP
CASB483/ CASB483WP

NEW
PRODUCT

Typical applications:
Wall sounder VAD Wall sounder VAD
This EN 54-23 compliant sounder (weatherproof)
beacon visual alarm device (VAD)
is suitable for fire notification Description H (mm) W (mm) D (mm)
in commercial buildings. The
weatherproof variant, with an Wall sounder VAD 147 106 92
IP66 ingress protection rating, Wall sounder VAD 151 111 100
can be used in wet and outdoor (weatherproof)
environments.
Red (CASB483/WP) or white
(CASB493/WP) flash options
available.

Wall VAD Dimensions


CAB492W/CAB482W

NEW
PRODUCT

Typical applications:
Wall VAD (shallow base) Wall VAD (deep base)
A low-profile, low-current solution
to the latest EN 54-23 fire
standard, this fire alarm beacon
Description H (mm) W (mm) D (mm)
VAD. It is also compatible with a
range of bases making it suitable Wall VAD (shallow base) 93 93 38
for a variety of applications.
Wall VAD (deep base) 93 93 67
Red (CAB482W) or white
(CAB492W) flash options
available.

30 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Intelligent addressable systems
Devices - wall sounders

-
Ceiling VAD Dimensions
CAB492CS/CAB482CS

NEW
PRODUCT

Typical applications:
Ceiling VAD
This EN 54-23 certified, low-
current fire alarm beacon is
suitable for ceiling mounting. It is Description H (mm) W (mm) D (mm)
compatible with a shallow base Ceiling VAD 93 93 38
providing flexibility as to where
the VAD can be installed.
Red (CAB492CS) or white
(CAB482CS) flash options

CASB493/CASB493WP CAB492W/CAB482W CAB492CS/CAB482CS


Tones CASB483/CASB483WP
Flash rate (low power consumption) 0.5Hz 0.5Hz 0.5Hz
Operating current (depending on setting and LED colour) 13.4-47.5mA 12.5-45mA 12.5-45mA
IP protection IP21C Shallow base: IP33C IP21C
WP variant : IP66 Deep base: IP65

Catalogue numbers
Description Code Description Code
Wall sounder VAD, red, white flash 8500110FULL-0199X Wall VAD, red, white flash, deep base 812034FULL-0210X
Wall sounder VAD, red, red flash 8500111FULL-0197X Wall VAD, Wall VAD, red, red flash, shal¬low base 812035FULL-0211X
Wall sounder VAD, red, white flash, waterproof 8500114FULL-0200X Wall VAD, Wall VAD, red flash, deep base 812036FULL-0212X
Wall sounder VAD, red, red flash, waterproof 8500115FULL-0201X Ceiling VAD, red, white flash, shallow base 812050FULL-0269X
Wall VAD, red, white flash, shallow base 812033FULL-0209X Ceiling VAD, red, red flash, shallow base 812037FULL-0214X

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 31


Addressable fire systems
Devices - beam detectors

Beam detectors, typically used in large open


areas, such as airports, shopping centres and
warehouses

32 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Intelligent addressable systems
Devices - duct probe detector

Beam detectors Duct probe mounting kit


There are two available loop powered reflective The presence of smoke in a ventilation duct is
beam detectors in the intelligent addressable detected by sampling the airflow through the duct
range. The MAB50R has a range of up to 50 metres via two sampling tubes. A detector and base are
and the MAB100R has a range of up to 100 metres. mounted within the sampling chamber, which
Neither requires a power supply and are both is located on the external skin of the duct, with
equipped with a simple set up mode to enable easy sample and exhaust probes passing into the duct
and quick alignment during installation. in an area of low turbulence. The unit requires
an addressable optical detector and base and is
The beam detector is loop powered with one
supplied with full fixing instructions.
unique address, and has the ability to add address
text at the panel. There is a maximum limit of 20
per loop (based on loop loading calculations).

Addressable reflective Dimensions Duct probe unit


beam detector MDP201
H (mm) W(mm) D (mm)
MAB50R / MAB100R
210 130 120

H D

Typical applications: Typical applications: Duct probe unit shown with


optical detector fitted
Large open areas such as Allows access to the automatic Detecting presence of smoke in
warehouses, manufacturing plants, gain control data from the detector. ventilation ducts.
shopping centres, airports etc. The beam detector will show fire, Requires base and detector to be
fault and pre-alarm. ordered separately.

Features Features
MAB50R MAB100R
Operating range 5 to 50 metres 50 to 100 metres Duct width range 300mm to 1500mm
5 to 50 metres
Tolerance to beam misalignment Detector ± 0.8˚, Detector ± 0.8˚,
at 35% Prism ± 5.0˚ Prism ± 5.0˚ Duct air speed range 1m/s to 20m/s
Detector ± 0.8˚
Fire alarm thresholds 2.50dB (25%) 2.50dB (25%) Prism ± 5.0˚
3.74dB (35%) 3.74dB (35%)
6.02dB (50%) 6.02dB (50%) Temperature range -20°C or +60°C
Optical wavelength 880nm 880nm Optical wavelength 880nm

Beam detectors have 3 operating modes:


Catalogue numbers
Prism targeting mode designed to provide simple initial alignment Description Code
of beam and reflector assembly.
Reflective beam detector (50m range) MAB50R
Alignment mode enables accurate fine tuning of beam alignment
without the need for additional calibration equipment or a second Reflective beam detector (100m range) MAB100R
operator.
Mounting bracket MRBFP
Normal running mode during standard operation.
Wall sounder detail
Spare reflector MABR

Duct probe unit MDP201

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 33


Intelligent addressable systems
Devices - interfaces

Interfaces
We supply an extensive range of interfaces to support our control panels.
Interfaces allow for a wide variety of installations to be simplified without the
use of specialist or customised equipment. For assistance deciding which
interfaces will benefit you the most, contact our technical support team at
[email protected]

Zone monitor unit Spur isolator unit Shop monitor unit 3 channel I/O unit
CZMU352 CSI350 MSU840 CIO351

Typical applications: Typical applications: Typical applications: Typical applications:


The unit connects a zone of The spur isolator unit enables a The shop monitor unit is The 3 channel input/output
suitable conventional detectors spur of intelligent addressable designed to allow small units unit enables simple interfacing
(20 detectors per zone) and a devices to be connected to with conventional fire systems between the fire system and
separate zone of conventional a main analogue loop. This to be fully integrated with a other equipment such as nurse
callpoints (if required) to an simplifies the installation of main intelligent addressable fire call systems or access control
addressable panel. remote parts of buildings or system. systems. The inputs are fully
system extensions. monitored for open and short
It allows for easier connection to It is ideal for connecting individual circuits.
existing conventional detection The CSI350 doesn't take an shop units into a main shopping
zones, as long as the devices address in the number sequence. centre system. Relay contacts are rated at 30V dc
used are compatible. 1A. See below for further options.
Recommended no more than Recommended for use with

a zones worth of devices per conventional VADs (see p82).
isolator. Please note: A PSU (see p38) is
required to operate conventional
sounder circuits.
The MSU840 can have 2 sounder
circuits, each with up to 0.3A of
power.

Dimensions Catalogue numbers


D Description Code
1 2
Zone monitor unit CZMU352

Shop monitor unit MSU840


W
H Spur isolator unit CSI350

3 channel input/output unit resets on reset CIO351


(recognised as 1 address)

H 3 channel input/output unit resets on reset CIO351SST


W (recognised as 3 addresses)
D

Description H (mm) W (mm) D (mm) 3 channel input/output unit resets on silence alarms CIO351S

Interface style 1 1 88 147 60 230V ac relay unit CMIO353

Interface style 2 2 129 180 60

34 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Addressable fire systems
Devices - interfaces

230V ac relay unit 4 to 20mA interface


CMIO353 CGI420

Typical applications: Typical applications:


Enables simple interfacing Designed to interface with gas
between the fire system and detection modules and are
other equipment such as nurse compatible with Eaton intelligent
call systems or access control addressable control panels.
systems.
The supply to the gas detector is
The ability of the output unit to taken directly from the interface.
switch 230V ac mains at 8A makes
the unit ideal for plant control or
mains powered door holders.
The input is monitored for open
and short circuits therefore can
be used for fire input applications
such as monitoring sprinkler flow
switches.
If you require higher current
switching (10A) please see page
86 for MAR724.
Intelligent addressable systems
Devices - interfaces

Interfaces continued
4 way sounder controller unit
CSC354CPR

Typical applications:
The 4 way sounder controller unit (CSC354CPR) adds functionality
to your addressable panel by powering up to 4 lines of conventional
output devices.
The CSC354CPR gives access to Eaton’s extensive range of
conventional devices, including EN54-23 certified VADs, beacons,
signboards, bells and sounders.
It is ideal in situations where there is a requirement for devices with
a high current draw or where conventional sounder circuits are in a
remote location away from the fire alarm control panel.

Dimensions Catalogue numbers


Description H (mm) W (mm) D (mm) Description Code
4 way sounder controller Unit 300 300 74 4 way sounder controller unit) CSC354CPR

Mimic relay boards


CIOP4 / CIOP8

Typical applications:
These addressable mimic relay boards (CIOP4) and (CIOP8) are 4 and 8
way soft addressing output modules, incorporating integral short circuit
isolators.
The units are suitable for switching low voltage (24V dc at 1A
maximum), via a set of latching relay contacts.
The flexibility of these modules is further enhanced by the fact that
each output can be programmed for a range of triggers such as
disablement, fault, fire, test panel, test zone prealarm, fire routing
equipment, fire protecting equipment and reset with up to 16 different
trigger sources per output.
These units have an additional 4 inputs which can initiate a reset,
silence, evacuate and test function.

Dimensions Catalogue numbers


Description H (mm) W (mm) D (mm) Description Code
CIOP4/8 mimic relay board 180 244 63 Technical input/output unit CFC301

4 way mimic relay board, 4 inputs, 4 outputs CIOP4

8 way mimic relay board, 8 inputs, 8 outputs CIOP8


D

4 to 20mA interface CGI420

Mimic relay

36 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2018


Intelligent addressable systems
Devices - interfaces

Door release module


CIOP-7273

Typical applications:
The CIOP-7273 door release module allows addressable systems
to comply with the demands of class A doors and their release in
the event of the full range of scenarios as detailed in BS7273-4
standard the code of practice governing door holders and door release
mechanisms in the UK .
The units are 2 way soft addressed output modules that incorporate
integral short circuit isolators. They are suitable for switching low
voltage (24V DC @ 2A maximum) via a set of non-latching
relay contacts.
Compatible with the current range of Eaton intelligent addressable
control panels, their flexibility is further enhanced by the fact that each
output can be programmed for the full range of triggers required by
BS7273-4 such as disablement, fault and fire with additional triggers of
pre-alarm, fire routing equipment, fire protecting equipment. The trigger
source can be global, by panel, by loop, by zone or by address.
Units can be programmed using Eaton Site Installer software via the
RS232 port; external power is required for these modules.

Dimensions Catalogue numbers


Description H (mm) W (mm) D (mm) Description Code
BS 7273-4:2015 compatible 129 180 60 BS 7273-4:2015 compatible door release module CIOP-7273
door release module

Fan controller unit


FC6 and FC18

Typical applications:
FC18 and FC6 fan controller units work in conjunction with the Eaton's
range of intelligent addressable control panels, providing the capability
to control and display the status of AHU fans.
The units are connected to the control panel by means of the comms
loop, utilizing only one address whilst providing the ability to monitor
and control up to 18/6 AHU fans. Each FC18 and FC6 unit incorporates
its own CPU specifically configured to control the relevant input and
output logic making programming quick and easy using Eaton site
installer software.
Recently upgraded to be compatible with new Smoke Management
protocols. Both FC6 and FC18 are ideal for use in conjunction with
updated CF3000 panels and the new MCOM-FC interface module.

Dimensions Catalogue numbers


Description H (mm) W (mm) D (mm) Description Code
FC6 Fan controller unit 125 155 42 Fan controller unit (surface mount) FC6
(surface mount)
Fan controller unit (rack mount) FC18
FC18 Fan controller unit 133 482 30
(rack mount)
Fan Controller Unit FC6-AU
(Australia standard - supplied w/o back box)

FC6 Fan controller unit (surface mount) FC18 Fan controller unit (rack mount)

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 37


Micro interfaces
Whereas our standard interfaces are designed to be installed in the position
required on the loop, our range of micro interfaces are compact enough to sit
within a panels’ enclosure, or in our dedicated mini module enclosure (ULBU)
which can house up to 3 mini modules.

Micro zone Micro single channel Micro single channel MCOM variants
monitor unit input unit output unit The MCOM-R gives a 5 second
MIU872 MCIM MCOM pulse on reset, and is used
for connecting/resetting beam
Typical applications: Typical applications: Typical applications: detectors.

The micro zone monitor The micro single channel input The micro single channel output The MCOM-S is identified by
unit (MIU872) is suitable for unit (MCIM) is suitable for unit (MCOM) is suitable for the panel as a sounder and does
interfacing a zone of up to 20 monitoring a set of normally switching low voltage (24V dc at not reset when put into 'silence'
conventional detectors onto an open, volt free contacts such as 1A maximum), via a set of non mode, only resets once panel has
intelligent addressable control sprinkler system flow switches latching relay contacts. been reset.
panel. and auxiliary panel fire/fault The MCOM-FC is identified by the
signals. Other examples include It is also suitable for switching
It will operate with any HVAC control circuits, plant panel as a sounder. It will activate
non-fire input signals such as flow from its associate cause and
conventional detector in valve open contacts, generator shutdown control circuits, fire
configuration with a schottky door closure etc. effect programming. It will reset
start up, fire door closed etc. from a global reset not a global
diode type base (CDBB300).
silence command. Suitable for
use with fan controller devices for
smoke management.

38 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Intelligent addressable systems
Devices - micro interfaces

Installation into mini module box Features


1. Fit the unit in position in accordance to the mounting diagram below. MIU872 MCOM MCIM
2. Connect the unit according to standard connections.
Soft addressed   
3. Up to 3 units can be fitted inside a micro module box unit
Short circuit isolators   
Single address   

Catalogue numbers
Description Code

FR4 PCB Interface Plate Micro zone monitor unit MIU872


Secured to box with
2 self tapping screws.
MCOM Output Module MCOM

MCOM-S Output Module Sounder MCOM-S

MCOM-R Output Module Resettable MCOM-R


60mm
MCOM-FC Output Module Fan Controller MCOM-FC

MCIM Micro single channel input unit MCIM


180mm
130mm
Mini module box unit (empty box) ULBU

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 39


Intelligent addressable systems
Devices - network interfaces

Network interfaces
Eaton offer multiple network interfaces which allow our panels and devices a
wider variety of functionality. These network interfaces allow the connection of
the Eaton network system to a computer network, and PC based applications
such as site monitor, site graphic and web server.

Lon to RS232 adaptor Dual-channel LonWorks TCP/IP interface Lon network booster
EC0232 BMS interface EC400 EC540
EC200

Typical applications: Typical applications: Typical applications: Typical applications:


The EC0232 Lon to RS232 The EC200 dual-channel The EC400 is a high performance, The Lon network booster (EC540)
adapter allows connection of LonWorks BMS interface is an reliable and secure network is the solution to interconnect
our system network (LonWorks) "add-on" to the network which infrastructure device for accessing multiple EIA-709 channels.
devices to PC based applications translates the pre-configured Eaton Lon Network of intelligent
such as site monitor, site graphics network variables to a set of addressable control panels over This unit provides up to 5 ports
and web server. un-configured network variables intranet or ethernet. and routes packets between
which can then be bound to a these ports. In spite of its small
In addition to the standard BMS, giving full access to the fire The EC400’s built in configuration size the (EC540) provides best
adaptor, Eaton offer 2 variants network data. server manages up to 256 IP class performance and flexibility
for use with a HMX PA/VA Fibre Optic Point to Point
devices on 1 Link
IP channel without a in use.
system - the ECO232PAVA dedicated management PC.
with no handshaking, and the In order to provide the optimal
LonWorks Lon-Fiber Lon-Fiber diagnostic
Easy to understand LonWorks router configuration the (EC540)
EC0232PAVA3D with a 3 min
time delay. NODE ADAPTOR Fibre ADAPTOR
LEDs allow and supports 2 to 5 ports as well as
installers to installNODE
LonWorks

LonWorks

troubleshoot the device without the 2 operating modes "smart


Control Panel CFSFL02 CFSFL02 Control Panel
expert knowledge and dedicated switch mode" and "configured
& &
Network Card troubleshooting tool. Network Cardrouter mode".

Fibre Optic Multi-Drop Link


Fibre optic multi-drop link - Fibre Fibre Fibre
example network diagram

CFSFL02 CFSFL02 CFSFL02 CFSFL02


Lon-Fiber Lon-Fiber Lon-Fiber Lon-Fiber
ADAPTOR ADAPTOR ADAPTOR ADAPTOR

LonWorks LonWorks LonWorks LonWorks


NODE NODE NODE NODE
LonWorks Bus

LonWorks Bus

LonWorks Bus

LonWorks Bus

Control Panel Control Panel Control Panel Control Panel


& & & &
Network Card Network Card Network Card Network Card

LonWorks LonWorks LonWorks LonWorks


NODE NODE NODE NODE
Control Panel Control Panel Control Panel Control Panel
& & & &
Network Card Network Card Network Card Network Card

40 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Intelligent addressable systems
Devices - network interfaces

BACnet gateway Modbus gateway Single mode Lon to Dual channel Lon to
EC650B EC700 fibre optic adapter fibre optic adapter
CFSFL01 CFSFL02

Typical applications: Typical applications: Typical applications: Typical applications:


The BACnet gateway (EC650B) The modbus gateway is part of The single mode Lon to fiber The dual channel Lon to fiber
is a CEA- 709/BACnet gateway the InfraLINK range of network optic adapter (CFSFL01) allows optic adapter (CFSFL02) allows
which maps CEA-709 network infrastructure components from connection of the system connection of the system
variables (NVs) to standard partners. network (LonWorks) devices network (LonWorks) devices
BACnet server objects. When through optical fibre, and to allow through optical fibre, and to allow
ordered with this part code All of the modbus gateways both point to point or multi drop both point to point or multi drop
(EC650B), the LonWorks to feature a robust hardware platform topology. topology.
BACnet address mapping is pre- with high performance CPU and
loaded and ready for use with UART for fast communications
the the intelligent addressable without loss of data. The
CF3000 system interface board. LonWorks to modbus address
mapping is pre-loaded and ready
for use with the CF3000 fire
system interface board.

Catalogue numbers

Description Code Description Code

Dual-channel lonworks BMS interface (non handshake) EC200 TCP/IP interface EC400

Dual-channel lonworks BMS interface (handshaking) EC200H Lon network booster EC540

Dual-channel lonworks BMS interface EC200S Bacnet gateway EC650B


(self configuring for use with EC700)
Modbus gateway EC700
Lon to RS232 adapter EC0232
Single mode lon to fibre optic adaptor CFSFL01
Lon to RS232 adapter EC0232PAVA
(For HMX pa/va system - no handshake) Dual channel lon to fibre optic adaptor CFSFL02

Lon to RS232 adapter EC0232PAVA3D


(For HMX pa/va system - 3 min time delay)

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 41


Intelligent addressable systems
Devices - ancillaries

Ancillaries
A range of ancillaries are available to complement and extend the capability of
our existing hardware.

Loop splitter unit Mimic PCB SPS Range -


ZPCB2222 ZPCB2252MML / SPS-2423
ZPCB2252MSL SPS-2433
SPS-2453

Typical applications: Typical applications: Typical applications:


Allows expansion of the CF3000 Up to 250 outputs can be Offers a compact, robust and
intelligent addressable panel from connected to the mimic versatile power solution to
4 to 16 loops. PCBs (ZPCB2252MML) and installers, allowing them to safely
(ZPCB2252MSL). This offers more power fire detection and signaling
This interface is mainly applicable capability to the extensive options systems in small to large
in countries where the mixing of already offered by the CF3000 installations.
detectors, sounders, callpoints control panel.
and interfaces are not permissible Compact and discrete design
on the same loop or the number These boards are typical used for allows for these SPS to be
of devices per loop is limited to a geographical LED mimic displays. installed in a visible location such
small number. as a hotel lobby for instance.

Catalogue numbers
Description Code

Loop splitter unit ZPCB2222

Mimic PCB (master) ZPCB2252-MML

Mimic PCB (slave) ZPCB2252-MSL

Safety power supply 24V / 1.5A (batteries not supplied) SPS-2423

Safety power supply 24V / 2.5A (batteries not supplied) SPS-2433

Safety power supply 24V / 4.5A (batteries not supplied) SPS-2453

42 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Addressable fire systems
Devices - Wall Sounders

Wall sounder detail

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 43


Intelligent addressable systems
Devices - software and testing equipment

Software
Eaton offer a number of specialised programs to aid with the installation,
maintenance, functionality and servicing of our addressable systems. Installed
using the USB analogue systems panel interface (see p45) and a PC or
laptop, these software programs help to solidify our addressable systems'
capabilities and make it easier for users to control and organise the system on
their site.

Graphical visualisation Site monitor


software EF-SITEMONITOR
EFGVS

Typical applications: Typical applications:


Eaton Fire Graphic Visualisation Site monitor / webserver software
Software (EFGVS) is a state of is designed to monitor Eaton
the art and powerful supervision fire systems and allow quick PC
management tool for Eaton Fire based administration.
addressable systems.
Using a simple interface,
Users can monitor, visualise in 2D authorised users can view control
and 3D, control and interrogate panel event history, event status,
their systems to ensure alarms device properties and other
are located quickly and dealt with information depending on access
efficiently. permissions defined by the
system administrator.
Ergonomic and intuitive, EFGVS
includes a comprehensive list The software also work’s remotely
of advanced features offering and is accessible through the
the system designer and site desktop client software or a web
supervisor a very efficient tool browser. Multi-user access is
ensuring all information and supported.
controls be available at their
fingertips.
Catalogue numbers
Description Code Description Code

Graphical Visualisation Software license 1-2 Graphical Visualisation Premium Designer


EFGVS1-2 EFGVS-PREMIUM
panels including an EC0232 interface Software license including an EC0232 interface

Graphical Visualisation Software license up to 6 Interface to connect panel network (LONWorks)


EFGVS3-6 EC0322
panels including an EC0232 interface to PC (RS232)

Graphical Visualisation Software license up to Site monitor / webserver software EF–SITEMONITOR


EFGVS7-10
10 panels including an EC0232 interface
All software products except the server-linking option (-TCPIP) and the basic
Graphical Visualisation Software license above
10 panels including an EC0232 interface
EFGVS11-PLUS EFGVS-DESIGN versions, include EC0232 (p36) as standard

Graphical Visualisation Software license up to


EFGVS7-10-TCPIP
10 panels with TCP/IP interlink

Graphical Visualisation Software license above


EFGVS11-PLUS-TCPIP
10 panels with TCP/IP interlink

Graphical Visualisation Designer Software


EFGVS-DESIGN
license - no panel connectivity

44 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Intelligent addressable systems
Devices - software and testing equipment

Testing equipment
As well as offering complete fire systems, Eaton can also provide testing
equipment to ease the process of installation, commissioning, maintenance
and fault finding.

Loop tester kit USB analogue systems Addressable device


LP800KIT panel interface programmer
USBINT2 CF800PROG

Typical applications: Typical applications: Typical applications:


The loop tester kit is a hardware/ The analogue systems panel The addressable device programmer is a versatile tool to aid the
software combination that can interface is a universal serial installation, commissioning, maintenance and servicing of current
be used to test, commission bus converter that provides intelligent addressable devices and fire systems.
and fault find a loop of up to 200 conversions from RS232 to USB,
intelligent addressable devices TTL to USB or TTL to RS232. This unit is light, robust and easy to operate using a user friendly menu
(detectors, sounders, ancillary structure on 2 x 40 character LCD display. It is powered from a single
devices) without having to These options provide the PP3 size, heavy duty battery or an external supply.
connect the loop to the intelligent connectivity required between
a PC and intelligent addressable CF800PROG can:
addressable control panel.
control panels, wireless control Program detector modes (see p24).
The loop tester is connected panels, and wireless survey tools
between the loop and PC, and including our range of software Change address details
allows the engineer to quickly solutions (see page 44). Change heat detector settings
identify and locate any loop
device that is operating outside Read analogue levels
its operating conditions.

Catalogue numbers
Description Code

Loop tester kit LP800KIT

Addressable device programmer CF800PROG

USB panel interface USBINT2

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 45


UL intelligent addressable systems
Product Name

UL Systems
Underwriters Laboratories Inc. (UL) is an Shangri-la at the Fort and Times Square projects in
independent product safety certification South East Asia and several major projects in the
organisation, established in 1894, to develop Middle East including a major projects within the
standards and test procedures for products, prestigious Riyadh Financial District in the Kingdom
materials, components, assemblies, tools and of Saudi Arabia.
equipment. Chiefly dealing with product safety
The Eaton UL range is designed to provide a
it also evaluates and certifies the efficiency of
solution for all sizes of project, from the simple
a company’s business processes through its
small stand alone system to the large multi
magnificent system registration programs.
panel networked system with PA/VA and BMS
Since the launch of our UL Listed fire product integration.
range, several prestigious projects worldwide have
been supplied including Hyatt Resort and Spa,

46 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


UL intelligent addressable systems
Contents

Contents
UL listed fire systems range

Panels

ULCF3000 series panels 48

Devices

Addressable detectors 50 Conventional detectors 52

Horns and strobes 54 Pull stations 56

Interfaces 58 Micro interfaces 59

SIGNALING

4AC5
FIRE ALARM
EQUIPMENT

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 47


UL intelligent addressable systems
ULCF3000 series

ULCF3000 series
UL listed control panels

ULCF3000RM (wall mount red metal)

ULCF3000 (wall mount graphite)

The ULCF3000 series panels are UL listed, high Benefits


specification, wall or rack mounted fire panels. • Soft addressing
Combining sophisticated functionality with simple
• Large versatile touchscreen user interface
operation and aesthetically pleasing design,
the panels are available in a number of loop • Integral printer (optional)
configurations. Each panel is networkable with up • Integral battery and power supply
to 126 other Eaton UL fire panels. • 2 x 12Ah batteries included
• Flexible distributed network capability
The control panel has the ability to support complex
• Full range of compatible devices
cause and effect programming. A wide range of
user controllable functions make the system ideal • 4 notification appliance circuits
for a diverse range of projects, from industrial (NACs) outputs
applications through to large multi-site • 2 or 4 class A style 7 SLC loops SIGNALING
commercial developments. • PAS (Positive Alarm Sequence)

4AC5
FIRE ALARM
EQUIPMENT

48 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


UL intelligent addressable systems
ULCF3000 series

Dimensions
D2
D2
W
W

H
H

D1
D1
Description H (mm) W (mm) D1 (mm) D2 (mm)
ULCF3000 397 497 75 130
ULCF3000RM 398 505 48 118

Compatible repeater panels Features


ULCF3000PRG ULCTPR3000
The ULCF3000 has both a standard and a touchscreen Active or passive option  
repeater panel available. Ideal for larger sites, the
No programming required * 
repeater allows you to display the system information
Multi language capability  
from multiple locations.
Allows networking with other  
Eaton fire panels
Integral power supply  
*Except local text information

Catalogue numbers
Description Code Description Code
2 loop panel ULCF30002G 4 loop panel, integral printer, red metal box ULCF30004GPRM
4 loop panel ULCF30004G 2 loop panel, network card, red metal box ULCF30002GNCRM
2 loop panel, integral printer ULCF30002GP 4 loop panel, network card, red metal box ULCF30004GNCRM
4 loop panel, integral printer ULCF30004GP 2 loop panel, integral printer, network card, ULCF30002GPNCRM
red metal box
2 loop panel, network card ULCF30002GNC
4 loop panel, integral printer, network card, ULCF30004GPNCRM
4 loop panel, network card ULCF30004GNC red metal box
2 loop panel, integral printer, network card ULCF30002GPNC Rack mounted 2 loop panel ULR3000L2
4 loop panel, integral printer, network card ULCF30004GPNC Rack mounted 4 loop panel ULR3000L4
2 loop panel, red metal box ULCF30002GRM Rack mounted 2 loop panel c/w network card ULR3000L2NC
4 loop panel, red metal box ULCF30004GRM Rack mounted 4 loop panel c/w network card ULR3000L4NC
2 loop panel, integral printer, red metal box ULCF30002GPRM Loop connected repeater panel ULCF3000PRG
Touchscreen network repeater panel ULCTPR3000

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 49


UL intelligent addressable systems
Devices - detectors

Detectors
Our UL range has multiple options for intelligent addressable detectors. All
detectors are designed for optimum functionality in mid-large sized builds. They
are all soft addressed and have integral short circuit isolators.

Addressable Optical smoke detector Photo-thermal detector Heat detector


detector base ULCAP320 ULCAPT340 ULCAH330
UCAB300

Typical applications: Typical applications: Typical applications: Typical applications:


Specifically designed for use Suitable for most applications. Responds quickly to fast clean Environments where the ambient
with all of our UL addressable burning fires. conditions might cause false
detectors the UCAB base will be Fastest response to slow burning alarms with smoke detectors.
used in all builds. or smouldering fires which Maintains the advantage of
give rise to large visible smoke optical detectors when detecting Examples include areas with high
particles. smouldering fires. levels of dust or fumes.

Detector detail Addressable base detail

SIGNALING

50 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018

4AC5
UL intelligent addressable systems
Devices - detectors

Performance
Heat Class ULCAP320 ULCAPT340 ULCAH330

Heat element rating N/A 135°F ROR + Fixed 135°F, Fixed 135°, Fixed 194°F

Heat detector spacing N/A 50ft (heat alone 50ft


operation)

Heat class N/A A2S A2R

Dimensions

Dia

D1
D2

Diameter (mm) Depth (mm) Depth (mm)


Description (incl base) (excl base) (incl base)
Optical 104 33 45
Photo-thermal 104 43 55
Heat 104 43 55

Catalogue numbers
Description Code

ULCAP320 Optical smoke detector ULCAP320

ULCAPT340 Photo-thermal detector ULCAPT340

ULCAH330 Heat detector ULCAH330

Addressable detector base UCAB300

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 51


UL intelligent addressable systems
Devices - conventional detectors

Detectors
Our UL range has multiple options for conventional detectors. All detectors
have a removable detector chamber and drift compensation. The range of
detectors for different applications allow for all build requirements to be met.
As there is no UL certified conventional panel a ULMIU872 micro interface
(p59) is required in conjunction with a UL intelligent addressable panel to
use conventional detectors.

Optical smoke Photo-thermal Fixed heat detector


detector detector (135°F)
UCPD-2W UCPT-2W UCHT-2W

Typical applications: Typical applications: Typical applications:


Suitable for most applications. Responds quickly to fast clean Environments where the ambient
burning fires. conditions might cause false
Fastest response to slow burning alarms with smoke detectors.
or smouldering fires which Maintains the advantage of
give rise to large visible smoke optical detectors when detecting Examples include areas with high
particles. smouldering fires. levels of dust or fumes.

Performance
Heat class UCPD-2W UCPT-2W UCHT-2W

Heat element rating N/A 135°F 135°F

Heat detector spacing N/A 50ft (heat alone operation) 50ft

Mounting position Ceiling in open areas Ceiling in open areas Ceiling in open areas

SIGNALING

52 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018

4AC5
UL intelligent addressable systems
Devices - conventional detectors

Conventional
detector base
CB2E

Typical applications:
The CB2E has been specifically
designed for compatibility with
our UL range of conventional
detectors. It can be be used
in all builds with conventional
detectors.

Dimensions Catalogue numbers


Dia
Description Code

2 wire detector, optical UCPD-2W

2 wire detector, opto-heat UCPT-2W

D1 2 wire detector, fixed heat 135°f UCHT-2W


D2
Standard detector base CB2E

Diameter (mm) Depth (mm) Depth (mm)


Description (incl base) (incl base) (excl base)
Optical 104 45 33
Photo-thermal 104 55 43
Heat 104 55 43

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 53


UL intelligent addressable systems
Devices - horns and strobes

Horns and strobes


Our UL range incorporates a variety of audio and visual notification devices.
Each device has up to 48% savings in current draw compared to similar
products. The whole range is easy to install and has voltage test points for
quick troubleshooting and easy spot checking, saving time on both installation
and maintenance.

Wall mount horn Ceiling mount horn Wall mount horn Ceiling mount horn
HNR CN128972 strobe/synchronised strobe/synchronised
strobe strobe
CN127249/STR CN127464/CN127488

Typical applications: Typical applications: Typical applications:


The horns are ideal for retrofit The horns are ideal for retrofit With the range of settings for both audio and visual purposes, these
jobs, limited space environments jobs, limited space environments products are effectively 9 models in 1 appliance. With this functionality,
and pre-existing wire and pre-existing wire and both ceiling and wall mount options available, it will meet almost
configurations. configurations. any build requirements.
The synchronised option enhances both the sound and light output by
keeping the outputs of multiple devices in sync.

Dimensions
Dia D
W W D D

Description H (mm) W (mm) D (mm) Description Diameter (mm) Depth (mm)


Wall mount horn 133 116 56 Ceiling mount horn 166 34
HNR CN128972
Wall mount horn strobe/ 131 131 110 Ceiling mount horn/ 166 34
synchronised strobe synchronised strobe
CN126292/STR CN127464/CN127488

SIGNALING

54 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018

4AC5
UL intelligent addressable systems
Devices - horns and strobes

Wall mount outdoor Ceiling mount outdoor


synchronised strobe synchronised strobe
CN129013 CN124338

Typical applications:
The outdoor synchronised strobes are UL certified to meet adverse
weather conditions. They are perfect for builds where outdoor
indication is required.
These units use a universal, common mounting base making them
ideal for retrofit jobs, limited space environments and pre-existing wire
configurations.

Dimensions Catalogue Numbers

W D
Description Code

Wall mount horn HNR

Ceiling mount horn CN128972

Wall mount horn strobe CN127249

Ceiling mount horn strobe CN127464


H
Wall mount synchronised strobe STR

Ceiling mounted synchronised strobe CN127488

Wall mount outdoor synchronised strobe CN129013

Ceiling mount outdoor synchronised strobe CN124338

Description H (mm) W (mm) D (mm) WPSBB -R Exposed conduit, surface mount CN109751
back box (RED)
RSSWP* 131 131 110
WPSBB-R + WP-KIT Concealed conduit surface CN109751 + CN104486
*Both wall mount and ceiling mount variants
mount back box (RED)

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 55


UL intelligent addressable systems
Devices - pull stations

Pull stations
The addressable pull stations are constructed of high quality, die cast metal for
long lasting performance. The range consists of the UL listed MPS range of pull
stations and the UL listed fast response input initiating module (ULMCIM-C).

Single action Single action


addressable pull conventional
station pull station
UMPS-100/ SG42BK2
UMPS-100WP

Typical applications: Typical applications:


Indoor/weatherproof pull station Cost effective conventional
for use with addressable systems version of the single action
(UMPS-100/UMPS-100WP). pull station, must be used in
conjunction with ULMIU872.
A dual action model is also Back box ordered seperately.
available (UMPS-200, not shown),
where the push bar rotates
inward allowing the pull handle Pull station detail
to be grasped in a one
handed motion.

Dimensions Catalogue numbers

D
Description Code

Single action pull station, supplied with back box (addressable) UMPS-100

Weatherpoof single action pull station UMPS-100WP

Double action pull station UMPS-200

H Weatherproof double action pull station UMPS-200WP

Micro zone monitor unit ULMIU872

Micro single channel input unit (recognised as callpoint) ULMCIM-C

Conventional single action pull station SG42BK2


(back box ordered seperately)
W
Conventional double action pull station SG42BK1
(back box ordered seperately)

H (mm) W (mm) D (mm) Back box for conventional, surface mounting SGB32S

118 80 80 Back box for conventional, weatherproof SGB-32C

SIGNALING

56 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018

4AC5
UL intelligent addressable systems
Product Name

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 57


UL intelligent addressable systems
Devices - interfaces

Interfaces
We supply an extensive range of interfaces to support our UL control panels.
Interfaces allow for a wide variety of installations to be simplified without the
use of specialist or customised equipment. For assistance deciding which
interfaces will benefit you the most, contact our technical support team;
[email protected]

4 Way Sounder Shop monitor unit Spur isolator unit 3 channel I/O unit
Controller Unit ULCSUM355 ULCSI350 ULCIO351
ULCSC354

Typical applications: Typical applications: Typical applications: Typical applications:


The unit connects 4 lines of The shop monitor unit is The spur isolator unit enables a The 3 channel input/output
conventional output devices on a designed to allow small units spur of intelligent addressable unit enables simple interfacing
single address to an addressable with conventional fire systems devices to be connected to between the fire system and
panel. Ideal for when specialist to be fully integrated with a main a main analogue loop. This other equipment such as nurse
devices with a high current draw intelligent addressable simplifies the installation of call systems or access control
are required, such as Eaton’s UL fire system. remote parts of buildings or systems. The inputs are fully
ceiling and wall horns/strobes. system extensions. monitored for open and short
Or where conventional sounder It is ideal for connecting individual
circuits.
circuits are in a remote location shop units into a main shopping
away from the fire alarm centre system.
control panel.

230V ac relay unit Dimensions


ULCMIO353
D
D

H
H

W
Typical applications: W

Enables simple interfacing


between the fire system and other Description H (mm) W (mm) D (mm)
equipment such as nurse call Interface units 129 180 60
systems or access control systems.
4 way sounder controller unit 300 300 74
The ability of the output unit to
switch mains also makes the unit
ideal for plant control or mains
powered door holders.
The input is monitored for open
and short circuits so can be used
for fire input applications such as
monitoring sprinkler flow switches.

SIGNALING

58 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018

4AC5
UL intelligent addressable systems
Devices - micro interfaces

Micro interfaces
Whilst our standard UL interfaces are designed to be installed in the position
required on the loop, our range of micro interfaces can sit within a panels’
enclosure.

Micro single channel Micro single channel Micro zone


output units input units monitor unit
ULMCOM/ULMCOM-S ULMCIM/ULMCIM-C ULMIU872 Dimensions

W H

H (mm) W (mm) D (mm)


Typical applications: Typical applications: Typical applications:
65 35 18.5
The Micro Single Channel Output The Micro Single Channel Input The Micro Zone Monitor Unit
Unit (ULMCOM) is suitable for Unit (ULMCIM) is suitable for (ULMIU872) is suitable for
switching low voltage (24V dc at monitoring a set of normally monitoring a zone of up to 20 UL
1A maximum), via a set of non open, volt free contacts such as approved conventional detectors.
latching relay contacts. sprinkler system flow switches
and auxiliary panel fire/fault
It is also suitable for switching
signals. Other examples include
HVAC control circuits, plant
non-fire input signals such as flow
shutdown control circuits, fire
valve open contacts, generator
door closure etc.
start up, fire door closed etc.
Please be aware, we offer
The ULMCOM-S is identified by
the panel as a sounder.
The ULMCIM-C is identified an enclosure for our micro
by the panel as a call point and interfaces, see p38.
is designed for use with
pull stations.

Catalogue numbers

Description Code Description Code

4 way sounder controller unit ULCSC354 ULMCOM Micro single channel output unit ULMCOM
(recognised as output unit)
Shop monitor unit ULCSUM355
ULMCOM-S Micro single channel output unit ULMCOM-S
Spur isolator unit ULCSI350 (recognised as sounder)

3 Channel input/output unit resets on reset ULCIO351 ULMCIM Micro single channel input unit ULMCIM
(recognised as input unit)
3 Channel input/output unit rests on silence alarms ULCIO351S
ULMCIM-C Micro single channel input unit ULMCIM-C
120V/230V ac relay u.nit ULCMIO353 (recognised as callpoint)

Micro zone monitor unit ULMIU872 Mini module box unit (empty box) ULBU

SIGNALING

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 59

4AC5
60 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018
Two-wire and conventional systems
Contents

Contents
Two-wire and conventional fire systems
Two-wire and conventional fire system

BiWire Flexi controls panels 62

Two-wire fire system


BiWire Ultra controls panels 64 BiWire Ultra devices 66

Conventional panels

Conventional fire system


EFCV8 series panel 69 FXP2200 series panel 70 FXP5000 series panel 72

Conventional devices
Detectors and indicators 74 Bases 76 Beam detectors 76

Duct probe detector 77 Callpoints 78 Bells 79

Sounders 80 Visual alarm devices 82 Indicators 84

Sounder indicators 85 Door retainers 86 Auxiliary power supply 87

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 61


Conventional and two-wire systems
BiWire Flexi series

EFBW series
BiWire Flexi control panel

BiWire Flexi combines two technologies to provide Features


a truly versatile fire safety solution. • Configure zone wiring to work as either a
conventional or two-wire system
The panel can be configured to allow either two- • Available in 2, 4 and 8 zone variants
wire or conventional devices to work on a zone.
• Allows the connection of an existing
Each zone is individually configurable so a mixture
conventional system to a BiWire system
of types can therefore be installed on the same
system. This provides the flexibility to utilise all the • Compatible with two-wire and conventional
time-saving benefits of a two-wire system with the EN 54-23 certified visual alarm devices (VADs)
ability to use a wide range of conventional devices,
where required. Benefits
• Reduces stock-holding and enables the
The BiWire Flexi fire alarm system is certified to fire system to adapt to the demands of the
EN54 part2 and part 4 and is designed to meet the customer or application
recommendations of BS5839. • Can be used in a wide variety of applications
and is very simple to install
• Save time, money and effort when
undertaking system extensions and upgrades

62 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional and two-wire systems
BiWire Flexi series

Dimensions Catalogue numbers

Description Code
2 zone BiWire Flexi panel* EFBW2ZFLEXI
4 zone BiWire Flexi panel* EFBW4ZFLEXI
8 zone BiWire Flexi panel* EFBW8ZFLEXI
2 zone relays + FRE/FPE BWOB2Z
4 zone relays + FRE/FPE BWOB4Z
8 zone relays + FRE/FPE BWOB8Z
BiWire repeater panel* EFBWCV-REPEATER
BiWire End of line module BWEOLM-3
Conventional End of line module EOLM-1
12V, 5Ah battery (1pc*) *2 required MB512
H (mm) W (mm) D (mm) * Panels are shipped without batteries inside them. Batteries should be
ordered separately.
Complete Panel 336 375 134
Back Box 273 338 88-

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 63


Two-wire systems
BiWire Ultra series

EFBW series
BiWire Ultra control panel

“Two-wire
panel, offering
significant cable
and install cost
savings without
sacrificing
performance”
Eaton’s BiWire Ultra fire detection system, available Features
in 2, 4 and 8 zone, is unlike any other standard
conventional system as the panel, detectors, • Detectors and sounders share the same
sounders and EN54-23 approved beacons all share wiring
the same zone wiring. This delivers significant • One man test facility
savings in both cable and installation costs without • Class change input
sacrificing the systems capability. • Interlink relay functionality for connecting 2
BiWire Ultra panels together
Testing is simple, it only takes one person to review
and ensure the healthy state of the system. Benefits
• Reduced cost of installation
Its modern design and simple interface makes it an
ideal choice for small businesses, primary schools, • Simple system testing by a single fire alarm
retail stores, restaurants and small nursing homes. technician
• Capability to sound class change bell in
EFBW2ZONE EFBW4ZONE EFBW8ZONE schools
No. of zones 2 4 8 • Interlink relay allows for greater system
Detectors per zone 32 32 32 flexibility
Maximum loading 200mA 200mA 200mA • Comprehensive protection for safety of
per zone
building occupants
Repeater Port   

64 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Two-wire systems
BiWire Ultra series

Dimensions

Catalogue numbers
Description Code

2 zone BiWire Ultra panel* EFBW2ZONE-NB

4 zone BiWire Ultra panel* EFBW4ZONE-NB

8 zone BiWire Ultra panel* EFBW8ZONE-NB

BiWire End of line module BWEOLM-3


Description Height (mm) Width (mm) Depth (mm) Repeater panel* EFBWREPEATER
Complete Panel 336 375 134 12V, 5Ah battery (1pc*) *2 required MB512
Backbox 273 338 88
* Panels are shipped without batteries inside them. Batteries should be
ordered separately.

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 65


Two-wire systems
BiWire Ultra series

Compatible devices
Eaton’s BiWire Ultra System can support up to 416 devices* in total. Certified to EN54 parts 2 and 4 it is
designed to meet the recommendations in BS5839.

The new BiWire Ultra system offers innovative devices with the latest technology, including a unique set of
beacons that comply with EN54-23, the latest beacon standard.
*8 Zone panel

Wall sounder VAD Features


EF009SB
• Certified to EN54-3 and EN54-23
• High sound output and durable design

• Weatherproof option

Benefits
• Certified for Fire use
• Ideal for high noise environments
• Suitable for open areas, as well as outdoor use
• Easy to maintain and service

Dimensions D

Description H (mm) W (mm) D (mm)


Wall sounder VAD 110 110 100
Weatherproof variant
Weatherproof 106 106 91

Base sounder and base sounder VAD


Dia

EF5021BWS / EF5021BWSB
Features
D
• Available in both sounder only and sounder VAD
• Certified to EN54-3 & EN54-23
• Standalone base sounder or base sounder VAD offers the
flexibility of use with or without the detector

• Cover plate (optional)


Description Dia (mm) D (mm)
Benefits
Base sounder and base sounder VAD 115 44
• First fix base, offers a compact design and reduces time of
installation of the base with the detector
• Easy to maintain and service

ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO

66 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Two-wire systems
BiWire Ultra series

5 in 1 Detector
EFBW5IN1DET
Features
• Five modes in one detector
• Offers a range of detector types
• 360° indicator LED using lightpipe technology
• Quick and simple to install

• Easy to maintain/service

Benefits
• Suitable for a broad range of applications
• Wide viewing angle for increased LED visibility
• Positive “lock” indication
• Discreet design for incorporation into any decor Dia

Dimensions
Diameter (mm) Depth (mm) Depth (mm) D1
Description (incl base) (incl base) (excl base) D2

5 in 1 Detector 104 55 42

Surface/flush and weatherproof callpoint


W
EF201BWCP / EF203BWCPWP
Features
• Fast fit clip on front cover
• Heavy duty terminals H
• Two models available:
- Internal
- Weatherproof (IP65)
• Single tool for test and access
D
• Robust construction

Benefits Description H (mm) W (mm) D (mm)


• Quick and simple to install Flush mounted 87 87 36
• Easy to maintain and service
Surface mounted 87 87 57
• Versatile installation
• Weatherproof variant suitable for outside use Weatherproof 87 87 59

Catalogue numbers
Description Code

Wall sounder EF009 Optical BiWire Detector EFBWOPTDET

Wall sounder, weatherproof EF009WP Callpoint EF201BWCP

Wall sounder VAD EF009SB Callpoint weatherproof EF203BWCPWP

Wall sounder VAD, weatherproof EF009SBWP External Relay 24V BWEXTR24V

BiWire Ultra base sounder first fix EF5021BWS External Relay 230V BWEXTR230V

BiWire Ultra base sounder VAD first fix EF5021BWSB 2 Zone Option Board BWOB2Z

Standard base FXN520 4 Zone Option Board BWOB4Z

Detector 5 in 1 EFBW5IN1DET 8 Zone Option Board BWOB8Z

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 67


Conventional systems
EFCV series

EFCV8Z
Conventional control panel

Eaton’s 8 zone conventional fire system panel intrinsically safe conventional zone circuits, making
delivers a straightforward, intuituve interface that it suitable for industrial applications.
makes programming and maintenance simple.
Benefits
Approved to EN54-2&4, it offers a comprehensive
• Zones switchable between standard
set of functionalities in a modern, robust
conventional and intrinsically safe zones
and discrete enclosure. It’s appearance and
(using isolator barrier)
performance makes the panel well suited for
life safety notification in a wide variety of small • One man test facility
to medium sized buildings, particularly schools, • Class change input
warehouses, retail stores and office buildings. • Interlink relay functionality for connecting 2
panels together
With the addition of an isolator barrier the panel • Interlink relay allows forgreater system
has the additional flexibility to monitor standard or flexibility
EFCV8ZONE
• Supports an expansion card for Fire Routing
Equipment, Fire Protection Equipment and
No. of zones 8
fire relays per zone
Detectors per zone 32
Maximum loading per zone 32mA
• Modern and discreet enclosure
Repeater Port 
No. of sounder circuits 4
Maximum loading per sounder circuit 250mA

68 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional systems
EFCVSeries

Dimensions Catalogue numbers

Description Code
Eaton 8 Zone Conventional Panel* EFCV8Z-NB
Eaton 8 Zone Conventional Panel EFCV8Z
End of Line Module EOLM-1
8 Zone Relays + FRE/FPE BW0B8Z
12V, 5Ah battery (1pc*) *2 required MB512

* Panels are shipped without batteries inside them. Batteries should be


ordered separately.

H (mm) W (mm) D (mm)


Complete Panel 336 375 134
Back Box 273 338 88

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 69


Conventional systems
FX2200 series

FX2200CPD series
Conventional control panel

“A flexible
conventional
solution that
ensures ease
of use and high
reliability"

The FX2200CPD range of conventional control project specific requirements to be easily met, in a
panels provide a solution to any conventional competitive and cost effective package.
system requirement. The advanced features include
a simple “one-shot” user test facility, class change Benefits
contacts, battery voltage alarms and charger
• Compact design
temperature compensation, all included as standard
to ensure ease of use and high reliability. • Surface or semi-flush mounting
• Numerical access code (no lost keys)
Attention to detail is emphasised by the neat log • 2 or 4 zones panels
book holder feature, allowing essential records to • Flexible, high specification system
be stored close to hand, ready for quick reference.
• Simple “one-shot” auto-reset user test facility
For larger installations, custom configuration of
the panels offers even greater flexibility, allowing • Maintenance free poly switch circuit
protection, with auto reset

FX2202 FX2204
No. of zones 2 4
Detectors per zone 32 32
No. of alarm circuits 2 (4 on FX2202CR) 2 (4 on FX2204CR)

70 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional systems
FX2200 series

Compatible Repeater Panel

To complement the FX2200 range a repeater panel is


available for connection to the 4 zone control panel.
Specifically designed for ease of installation, it requires
only 2 interconnecting wires from the main panel, saving
material cost and labour time. Further repeater panels
can be cascaded which does not affect standby time
as each has its own mains supply and standby battery.
The repeater displays all the same functions as the main
panel and includes an indicator test facility.

Features
• Charger with built in temperature
compensation
• Displays essential information at other key
locations in a large building/site
• Zone fire and fault conditions
• Test mode in operation
• Zones or alarm lines in disabled mode

Dimensions Catalogue numbers


D1
W
Description Code
Conventional 2 Zone Panel FX2202CPD
Conventional 2 Zone Panel* FX2202CPD-NB
Conventional 4 Zone Panel FX2204CPD
Conventional 4 Zone Panel* FX2204CPD-NB

MUTE SCROLL
Conventional Repeater Panel FXRP2200
H
BUZZER

1 2 3 4 5
Steel Back Box (for use with FX2202/4/8) FX22003300 MB
Fire Alarm System Log Book MFALOG
12V 3.2Ah SLA *1 required MB3A212

* Panels are shipped without batteries inside them. Batteries should be


ordered separately.

D2

H (mm) W (mm) D1 (mm) D2 (mm)


2 / 4 zone panel 270 332 45 47
Cut-out 265 327 - -
Note: If surface mounting add D1 and D2 to obtain depth dimension

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 71


Conventional systems
FXP5000 series

FXP5000 series
Conventional control panel

“Contemporary
and compact panel
design that provides
a solution to any
conventional system
NEW
PRODUCT requirement”

The new FXP5000 conventional control panel is Benefits


currently available in a 16 zone version. The panel • Zonal relay card as standard
features an array of user friendly features and are
• One man test facility
available at very competitive prices. The attractive
flush or surface mountable plastic enclosure, • Non latching zone feature
with metal back box, has been designed through • Class change input
intensive voice of the customer research to provide • Fire and fault relays
ample space for termination of cables. • Discreet enclosure
• Supplied complete with battery for 24 hour
standby

FXP50016
No. of zones 16
Detectors per zone 30
No. of alarm circuits 4
Zonal relay card 

72 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional systems
FXP5000 series

Dimensions
D1 W2

D2

H1

H2

W1

Description H1 (mm) W1 (mm) D1 (mm) H2 (mm) W2 (mm) D2 (mm)


Total height Total width Total depth Back box Back box width Back box
height depth
16 Zone 276 375 136 232 335 96

Catalogue numbers
Description Code
16 zone control panel FXP50016
Fire alarm system log book MFALOG
16 zone panel* EFCV16Z-NB
12V 4Ah SLA battery *2 required MB412

* Panels are shipped without batteries inside them. Batteries should be


ordered separately.

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 73


Conventional systems
Devices - detectors and remote indicator

Detectors and remote indicator


The conventional range offers a multi-mode, 5 in 1 detector (FXN922), covering many building needs.
It’s quick and simple to install with a stylish low profile design. The detector is mounted on our standard
conventional base (FXN520) but can also be used in conjunction with our relay base (FXN520R) for local
switching. Each detector is fitted with a 360˚ viewable LED for indication.
This multi-mode detector can be configured to operate as either an optical detector, photo-thermal
detector or 1 of 3 heat detector modes (A1R, BS, CS) using the four position switches located at the back
of the detector. The FXN922 is certified for use in all 5 modes.

Multimode detector Optical smoke Photo-thermal


FXN922 detector mode detector mode
Typical applications: Typical applications:
Suitable for most applications. Responds quickly to fast clean
burning fires.
Fastest response to slow burning
or smouldering fires which Maintains the advantage of
give rise to large visible smoke optical detectors when detecting
particles. smouldering fires.

Rate of rise heat Fixed heat detector


detector mode (77°) mode
Typical applications: Typical applications:
Environments where the ambient Environments where a change in
conditions might cause false temperature is a likely occurrence.
alarms with smoke detectors. Using a fixed heat negates
false alarms from insignificant
Examples include areas with high temperature rises.
levels of dust or fumes.

Fixed heat detector Note:


(92°) mode
We can also supply separate
Typical applications: detectors for each individual
mode if they are required.
Environments where the ambient These are displayed in the
heat levels are likely to be above catalogue numbers in the
Base not included. See p76 normal temperatures, such as table over the page.
for compatible bases. restaurant kitchens.

Remote indicator Dimensions


FX251D D

Typical applications:
The remote indicator is ideal for
H
applications such as void spaces
or outside locked or inaccessible
rooms to provide indication of
the activation of an automatic
detector.
W

Description H (mm) W (mm) D (mm)


Remote indicator 87 87 49

ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO

74 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Conventional systems
Devices - detectors and remote indicators

Performance

Feature Optical Photo-thermal Rate of rise Fixed heat Fixed heat


smoke mode mode mode 77 ˚C mode 92 ˚C mode

Area coverage 100m2 100m2 50m2 50m2 50m2


(subject to local standards)

Heat class N/A A2S A1R BS CS

Alarm temperature N/A 60 ˚C 60 ˚C 77 ˚C 92 ˚C

Dimensions Switch settings


Dia

On

D1
D2 On

1 2 3 4
Off
Diameter (mm) Depth (mm) Depth (mm)
Description (incl base) (incl base) (excl base) Description SW1 SW2 SW3 SW4
Multimode detector* 104 42 55 Optical mode - OFF OFF OFF
Optical smoke 104 33 45
Photo-thermal mode - OFF OFF ON
detector
* All other conventional detectors share same dimensions Rate of rise mode - ON OFF OFF

Fixed heat 77° mode - OFF OFF ON

Fixed heat 92° mode - ON ON OFF

Catalogue numbers
Description Code

5 in 1 Multi-Mode Detector FXN922

Optical Smoke Detector FXN533

Photo-Thermal Detector FXN632

Rate of Rise Heat detector FXN525

Fixed Heat Detector 77 ˚C FXN524

Fixed Heat Detector 92 ˚C FXN526

Remote Indicator FX251D

Weatherproof Remote Indicator CIR301WP

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 75


Conventional systems
Devices - bases and beam detectors

Bases Beam detectors


There are two types of conventional detector There are two zone powered reflective beam
bases, compatible with our range of detector detectors designed to be fully compatible with our
heads to provide a wide functionality for different conventional control panels. The MBD50R has a
applications. The standard base (FXN520) is a range of up to 50 meters and the MBD100R has a
general use product, providing a foundation for our range of up to 100 metres. Neither require a power
conventional detectors, whereas the relay base supply and both are equipped with a simple set up
(FXN520R) provides a local relay signal in the event mode to enable easy and quick alignment during
of its host detector being triggered, making it ideal installation.
for instigating a local response.

Standard base Relay base Conventional reflective Dimensions


FXN520 FXN520R beam detector
MBD50R / MBD100R

H D

Typical applications: Typical applications: Typical applications:


General use product, suitable for Areas where a local response is Large open areas such as H (mm) W(mm) D (mm)
use in most indoor applications. required. warehouses, manufacturing 210 130 120
plants, shopping centres, airports
etc.

Dimensions Features
MBD50R MBD100R
Operating range 5 to 50 metres 50 to 100 metres
Tolerance to beam misalignment Detector ± 0.8˚, Detector ± 0.8˚,
at 35% prism ± 5.0˚ prism ± 5.0˚
D
D Fire alarm thresholds 2.50dB (25%) 2.50dB (25%)
3.74dB (35%) 3.74dB (35%)
6.02dB (50%) 6.02dB (50%)
Optical wavelength 880nm 880nm
Dia
Dia

Standard base Relay base Beam detectors have 3 operating modes:


Prism targeting mode designed to provide simple initial alignment of
Description Dia (mm) D (mm) beam and reflector assembly.
Standard base 104 22 Alignment mode enables accurate fine tuning of beam alignment
Relay base 102 40 without the need for additional calibration equipment or a second
operator.
Normal running mode during standard operation.

ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO

76 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Conventional systems
Devices - duct probe detector

Duct probe detector


The presence of smoke in a ventilation duct is
detected by sampling the airflow through the duct
via two sampling tubes. An optical detector and
base are mounted within the sampling chamber,
which is located on the external skin of the duct,
with sample and exhaust probes passing into the
duct in an area of low turbulence.

Duct probe unit


MDP201

Typical applications: Duct probe unit shown with


optical detector - detector
Detecting presence of smoke in and base must be ordered
ventilation ducts. separately.

Features

Duct width range 300mm to 1500mm


5 to 50 metres
Duct air speed range 1m/s to 20m/s
Detector ± 0.8˚
Prism ± 5.0˚
Temperature range -20°C or +60°C

Catalogue numbers
Description Code

Standard base FXN520

Relay base FXN520R

Reflective beam detector (50m range) MBD50R

Reflective beam detector (100m range) MBD100R


Duct probe units can be used to detect the
Mounting bracket MRBFP presence of smoke in a ventilation duct
Duct probe unit MDP201

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 77


Conventional systems
Devices - callpoints

Callpoints
Two versions of the conventional callpoint are available, the surface or flush
mounted FX201 or the weatherproof FX203. Both have an integral short circuit
isolator and are very simple to install. The callpoints are packaged with 2
frangible glass elements and test key, with a comprehensive range of further
devices available.

Surface/flush mounted Weatherproof callpoint Dimensions


callpoint FX203
FX201 W

Typical applications: Typical applications: Description H (mm) W (mm) D (mm)


General use product, suitable for Builds requiring a callpoint in Surface mounted 87 87 57
use in most indoor applications. harsh conditions. For example,
Flush mounted 87 87 36
outside or in a wash down area.
Weatherproof 87 87 59

Features Further accessories:


FX201 FX203
Fast fit clip  
Heavy duty terminals  
Ingress protection IP24D IP65

Catalogue Numbers
Callpoint shown with protective
hinged cover
Description Code

Surface/flush callpoint FX201

Weatherproof callpoint FX203

CXPC Protective hinged cover (pack of 10) CXPC

Spacer plates (pack of 10) MBGSP

MBGBEZ Recessing bezels (pack of 10) 4990005FUL-0194

MBGREKIT Resettable element kit (pack of 10) 4990010FUL-0045

FX5G Spare break glasses (pack of 10) FX5G


Callpoint recessing bezel
Earth continuity links (pack of 5) MBG119

MFBGKEY3 Callpoint keys (pack of 10) 4990009FUL-0040


ERTI
N C F
IO I
C
T

AT
PREVEN

LPCB
ION BO

78 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


S

A
S

R
LO D
Conventional systems
Devices - bells

Bells
Bells still remain a popular choice for many
applications where they can sometimes be used as
a signal for non-fire purposes, such as class change
in a school.

Internal 6 inch bell


FX006

Typical applications:
Can be used for non-fire
applications, such as class change
in a school. Bells can be used for non fire applications
such as class change in a school

Dimensions Sound output


FX006 MWB824
D

Sound Output 93-95dB(A) at 24V dc 95dB(A) (+/-2)

Catalogue numbers
Dia

Description Code

FX006 Internal 6 inch bell FX006

Internal 6 inch bell

Description Dia (mm) D (mm)


6 inch internal bell 152 63

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 79


Conventional systems
Devices - sounders

Sounders
We have an extensive range of conventional sounders, designed to meet
every specification’s functional and aesthetic needs. Completely EN54 Pt. 3
certified, each sounder offers a unique solution to your conventional system
requirements.

Flush sounder Surface sounder Weatherproof High output wall


FX003 FX002SB surface sounder sounder
FX002DB FX007

Typical applications: Typical applications: Typical applications: Typical applications:


Ideal for retail, hotel and This all-purpose sounder has been The weatherproof sounder With a maximum output of
residential applications such as designed to be both robust and is perfect for harsh weather 120dB(a), this sounder is ideal for
sheltered housing. aesthetically pleasing to meet conditions where a sounder is areas with high ambient noise
many build requirements. needed. With selectable tones levels like warehouses.
a high volume can be easily
achieved meaning this sounder
functions well in outdoor settings.

Low current Base mountable


wall sounder sounder
MLC624 FXN824

Typical applications: Typical applications:


Designed to provide a high With a slim and aesthetically
sound output with a low current pleasing design this base sounder
consumption the MLC624 is is ideal for applications such as
perfect for areas where high hotel bedrooms where a detector/
sound levels need to be achieved sounder or a detector/sounder-
but sounder circuit capacity is beacon is required.
limited.
Please note a detector base is still Wall sounder detail
required when used in conjunction
with a detector

80 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional systems
Devices - sounders

Sound output
FX003 FX002 FX007 MLC624 FXN824

Sound output 98dB(a) at 1 Metre 105dB(a) max (+/-2) 120dB(a) (+/-2) 100dB(a) at 24V dc 80/90dB(a) (+/-3) @
(+/-2) at 24V dc Max at 1m (tone 5) 1 Metre
114dB(a) (+/-2) Max
at 1m (tone3)

Tones 32 32 32 3 8

Dimensions
D D
D
W

D Dia

H D

Dia
Dia
W

Flush sounder Wall sounder Surface sounder Weatherproof surface Base mountable
sounder sounder

Description H (mm) W (mm) D (mm) Description Dia (mm) D (mm)


Flush sounder 86 86 36 Surface sounder 93 63
High output wall sounder 105 105 95 Weatherproof surface sounder 93 93

Low current wall sounder 105 105 95 Base mountable sounder 111 26

Catalogue Numbers

Description Code

FX003 Flush sounder, red 550001FULL-0001X

FX003W Flush sounder, white 550015FULL-0017X

MFSSBB Back box for FX003, red 591001FULL-0016

FX002SB Low profile surface sounder, red FX002SB

FX002DB Weatherproof deep base surface sounder back FX002DB


box, red (IP65)

FX007 High output wall sounder 651004FULL-0009X

MLC624 Low current wall sounder 650001FULL-0003X

FXN824 Base mountable sounder 666058FULL-0098X

MDS824COV Blanking plate for FXN824 (pack of 5) 590037FULL-0305

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 81


Conventional systems
Devices - EN54-23 visual alarm devices

Visual alarm devices (VADs)


From 31st December 2013 a new beacon standard, Solista LX wall Solista LX ceiling
EN 54-23 became mandatory throughout the EU FXSOLWRS FXSOLCWS
where Construction Product Regulation (CPR)
applies. It directly affects the use of visual alarm
devices (VADs) in fire detection and alarm systems 1Hz 1Hz
FLASH FLASH
for non-domestic premises. Its purpose is to
standardise the requirements, test methods and
functional criteria of VADs to ensure that their
visual performance is measured and presented in a
uniform manner.
Eaton's LX range has been designed to comply
with the new EN 54-23 standard. With current
consumption as low as 10mA, the range has Typical applications: Typical applications:
been developed to provide the lowest current With both a shallow base and The ceiling option Solista helps
consumption with the highest possible coverage. deep base option the Solista to cover different types of room
Three years in the making, the LX range, available meets requirements of a large sizes to meet the requirements of
range of builds. the CoP 0001 design guidelines.
for wall and ceiling applications, features a number
of patented technologies including an innovative
lens and flash pattern.

RoLP LX wall Symphoni LX wall Symphoni LX WP wall These products are all red
FXROLPWR FXSYG1WR (weatherproof) flash, for more options
please contact:
FXSYG1WR-WP
[email protected]

1Hz 1Hz 1Hz


FLASH FLASH FLASH

Typical applications: Typical applications: Typical applications:


The RoLP LX Wall is ideal for The Symphoni LX Wall base can The Symphoni LX WP Wall device
dual use applications where a be used in combination with any offers a weatherproof alternative
visual alarm device is required in standard Symphoni sounder. to the Symphoni LX Wall device.
addition to an audible alarm. With an ingress protection rating
Its high sound output makes it of IP66, it is suited for wet and
The RoLP LX Wall is available suitable for open areas or areas outdoor environments.
to use with any standard RoLP where there is higher than normal
sounder. background noise.

Performance
Solista LX wall Solista LX ceiling RoLP LX wall Symphoni LX wall Symphoni LX
WP wall
Sound output N/A N/A 102dB(A) (Typical tone 100dB(A) (Typical tone 100dB(A) (Typical tone
3 - RoLP) 3 - Symphoni) 3 - Symphoni)
Minimum current consumption 10mA 10mA 22mA 15mA 15mA
EN54-23 coverage reference W-2.4-7.5 C-3-7.5 W-2.4-7.5 W-2.4-7.5 W-2.4-7.5
Coverage volume 135m3 (15m3) 132m3 (21m3) 135m3 (15m3) 135m3 (15m3) 135m3 (15m3)
Flash rate 1Hz (switchable to 1Hz (switchable to 1Hz (switchable to 1Hz (switchable to 1Hz (switchable to
0.5Hz) 0.5Hz) 0.5Hz) 0.5Hz) 0.5Hz)

82 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional systems
Devices - EN54-23 visual alarm devices

Dimensions
Dia
Dia D1 Dia
Dia D1 W
W D

DEEP BASE DEEP BASE

H
Dia

Dia

W
SHALLOW BASE SHALLOW BASE
D2 D2
SHALLOW
SHALLOW

SHALLOW
SHALLOW

BASE

D
BASE

D
D2
D2

DEEP

DEEP

D
BASE
BASE

DEEP BASE
DEEP BASE

D D

D
D1
D1
BASE

BASE

Solista LX wall Solista LX ceiling RoLP LX wall

WW D
W
W D

H
H
H

W
W

D
D

D
D

H
H

Symphoni LX wall Symphoni LX WP wall

Dia D W H
Description (mm) (mm) (mm) (mm)
Solista LX wall deep base 93 66 - -

Solista LX wall shallow base 93 38 - -

Solista LX ceiling shallow base 93 37

RoLP LX wall - 95 95 135

Symphoni LX wall - 92 106 147

Symphoni LX WP wall - 92 106 147

Catalogue numbers
Description Code Description Code
cc2478 Fire Systems & VADs Design Guide.qxp_Layout 1 12/02/2014 09:37 Page 1

FXSOLWRS Solista wall red body shallow base 812013FULL-0237X Deep base for Solista LX ceiling FX000WWP
Fire Systems Design Pocket Guide
BS 5839 Part 1:2013 and CoP 0001 for Visual Alarm Devices

For more guidance


FXSOLWRD Solista wall red body deep base 812005FULL-0107X Fire Installers Mate
on EN-54-23 and A guide to fire system design

FXSOLCWS Solista LX ceiling 812022FULL-0123X placement of VADs,


FXROLPWR RoLP wall red body base and sounder 8500025FULL-0025X refer to our Fire
FXROLPWR-B RoLP wall red body base only 8500040FULL-0219X
Installer's Mate
pocket guide.
FXSYG1WR Symphoni LX wall red body 8500045FULL-0233X

FXSYR-B Symphoni LX wall base red body 8500095FULL-0231X


(Part code CFS-
CC2478-FIM)
FXSYG1WR-WP Symphoni LX wall weatherproof 8500050FULL-0249X
red body

FXSYR-B-WP Symphoni LX wall weatherproof 8500100FULL-0247X


base red body

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 83


Conventional systems
Devices - indicators

Indicators
In areas which do not have to meet the new regulations regarding EN54-23 visual
alarm devices, our range of indicators can still provide reliable light indication.

Low profile Weatherproof


LED indicator LED indicator
MLB124SB MLB124DB

Typical applications: Typical applications:


In regions where the EN54‑23 The weatherproof version of the
VADs standard is not a LED indicator provides an IP65
requirement, the LED indicator can option ideal for outdoor use.
be used as an indicating device.

Dimensions Note: From 31st December 2013 a new beacon


standard, EN 54-23 became mandatory across
Europe where Construction Product Regulation
D (CPR) applies. If you are in a region where this
standard applies please understand that these
D

indicators do not meet the requirements of the new


Dia Dia
standards - see p82 for compliant beacons and
Weatherproof LED indicator
sounder beacons
Low profile LED indicator

Description W (mm) D (mm)


Low profile LED indicator 95 53
Weatherproof LED indicator 95 80

Catalogue numbers
Description Code

MLB124SB Low profile LED beacon 811012FULL-0006

MLB124DB Weatherproof LED beacon 811013FULL-0007

84 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional systems
Devices - sounder indicators

Sounder indicators
In areas which do not have to meet the new regulations regarding EN54-23
visual alarm devices, our range of sounder indicators can still provide excellent
sound quality and light indication.

Xenon sounder Weatherproof Xenon


indicator sounder indicator Dimensions
FL-RL-R-S FL-RL-R-D D D

Dia
Dia

Xenon sounder indicator Weatherproof xenon


sounder indicator

Typical applications: Typical applications: Description Dia (mm) D (mm)

In regions where the EN54‑23 The weatherproof version of the Xenon sounder indicator 93 92
VADs standard is not a sounder indicator is IP65 rated Weatherproof xenon sounder indicator 93 121
requirement, the xenon sounder which allows for installation in
indicator provides an alternative harsher environments.
option to the xenon indicator
- where an audible warning
is required in addition to light
indication.

Sound output Note: From 31st December 2013 a new beacon


XENON sounder indicator, standard, EN 54-23 became mandatory across
FL-RL-R-S/FL-RL-R-D Europe where Construction Product Regulation
Sound output 101dB(a) at 24V dc (typical tone 3)
(CPR) applies. If you are in a region where this
standard applies please understand that these
Tones 32
indicators do not meet the requirements of the new
standards - see p82 for compliant beacons and
sounder beacons
Catalogue numbers
Description Code

FL-RL-R-S Conventional xenon sounder indicator FL-RL-R-S

FL-RL-R-D Weatherproof IP65 xenon sounder indicator 640031FULL-0111X

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 85


Conventional systems
Devices - door retainers and relay unit

Door retainers and relay unit


Door retainers enable doors to be held open under normal conditions but
automatically be released in the event of fire alarm activation.
Eaton have a range of door retainers which are robust and simple to install.
Both floor and wall mounted retainers, with either mains or 24V dc power
supplied variations, are available.

Heavy duty Compact door retainer Heavy duty relay unit


door retainer FX021240LC/ MAR724
MDR240/MDR24L FX02124VLC

Typical applications: Typical applications: Typical applications:


Robust and simple to install, the Equally as reliable, the compact Designed for interfacing heavy loads such as door release units or plant
heavy duty door retainer is ideal door retainer is also a good choice shut down equipment with fire alarm systems.
for a wide range of applications, for nursing homes, hospitals and
such as nursing homes, hospitals, also busy corridors. This unit is simple to fix and install and the neat unobtrusive design
schools and industrial premises. makes it suitable for use in a wide range of areas.
The heavy duty relay unit is powered by 24V dc external supply and is
provided with 2 separate sets of changeover contacts.
Can switch 230V ac mains at 10A

Performance Catalogue numbers


MDR240 MDR24L FX021240LC FX02124VLC Description Code

Holding force 40kg 40kg 45kg 40kg Mains powered heavy duty door retainer MDR240

Power 1.2VA 40mA 1.2VA 40mA 24V dc heavy duty door retainer MDR24L
consumption
Floor mounting bracket for heavy duty door retainers ZMDRFBB

Mains powered compact door retainer FX021240LC

24V dc compact door retainer FX02124VLC

Floor mounting bracket for compact door retainers FX021LCFB

Spare striker plate for either magnet ZMDRSWIV

Heavy duty relay unit MAR724

86 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Conventional systems
Devices - power supply

Power supply
Specifically recommended as an auxiliary power
supply unit for fire detection system components
such as electromagnets, notification devices, etc.
Using the unit in large systems eliminates the
problem of long power cable runs which simplifies
installation.

EN54 pt.4 approved power supply unit


SPS Range

Typical applications:
The new range of EN 54-4 certified safety power supplies offer a
compact, robust and versatile power solution to installers, allowing
them to safely power fire detection and signaling systems in small to
large installations.

Compact and discrete design allows for these SPS to be installed in


a visible location such as a hotel lobby for instance. Comprehensive
yet simple status indicators on the front of the unit help installers,
commissioners and maintainers assess status of the unit.

Catalogue numbers
Description Code

Safety power supply 24V / 1.5A (batteries not supplied) SPS-2423

Safety power supply 24V / 2.5A (batteries not supplied) SPS-2433

Safety power supply 24V / 4.5A (batteries not supplied) SPS-2453

Door retainers enable doors to be held open under


normal conditions but automatically be released in
the event of fire alarm activation.

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 87


Conventional systems
Devices – Optical/acoustic sign boards

Optical/acoustic sign boards


Optical and acoustic sign boards are designed to show the state of alarm in
fire detection units. Eaton’s 5900 LX wall alarm device series comply with
standards EN54-23 (optical part) and EN54-3 (acoustic part).

Series 5900 LX certified alarm panel


5945-CSA/5955-CSA/5965-CSA

Typical applications:
The 5900 LX wall alarm device series comprises three versions that are
Features
available with optical, acoustic and optical-acoustic warnings. • Certified to UNI EN54-3 and UNI EN54-23
The optical warning is provided by a highly effective LED flash that • Protection rating IP54
can cover an area of 8.5m x 8.5m at an installation height of 4.2m.
The acoustic warning is provided by a high power internal siren with a • Operating temperature -10°C to +50°C
sound pressure of 85 dB at 1m. • Flash colour – white
The device has a display which shows “FIRE ALARM” backlit by LEDs • Housing – Self-extinguishing white thermos plastic
in the event of an alarm.
Its IP54 protection rating means that the device can be used in both
indoors and outdoors environments, including damp, dusty settings.

Features Dimensions
5945-CSA 5955-CSA 5965-CSA
Optical alarm warning   
Acoustic alarm warning   
Display lighting - LEDs   
Nominal voltage 24V DC   
Power consumption @24V 120mA 100mA 130 mA

Description H1 (mm) H2 (mm) W (mm) D1 (mm) D2 (mm)


Sign board 170 132 365 72 50
Catalogue numbers
Description Code

Optical alarm warning sign board 5945-CSA

Acoustic alarm warning sign board 5955-CSA

Optical- acoustic warning sign board 5965-CSA

88 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 89
Emergency voice communications
Contents

Contents
Emergency voice communications

Panels

Network exchange units 91 Non network exchange units 93

Devices

Outstations 95

Emergency assist alarm 97

90 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Emergency voice communications
Network exchange units

VoCALL Network
*Possible to connect up to 4x masters

Our range of EVCS control units cover functionality for all builds, whether small
and basic or larger and more complex. All parts are designed to fully comply with
BS5839 part 9 2011 with EN54-4-A2 compliant power supplies and chargers.

Network master
handset Features
CFVCWM Up to 4 network master handsets per system 
Controls up to 152 lines (19 x 8 line exchange units) 
Monitored handset 
Large high contrast display (4 x 20 character) 
Dual network ports 
Remote powered handsets, no mains required 
Full system event log (fault & configuration) 

Dimensions
W D

Description H (mm) W (mm) D (mm)


VoCALL Network Master Handset 300 300 65

*Please check with our technical team if dimensions are critical as they may have changed
from time of print

Each system can have up to 4 VoCALL Network 8 line network exchange unit
Master Handsets which gives great flexibility to CFVCX8
larger installations allowing all calls to be monitored
from various control points.
• Wall or desk mount
• Graphical display
• Calls can be made by dialling or selecting the
outstation name

Up to 8 lines can be connected


The VoCALL Network 8 Line
to each distributed exchange, and
Exchange Unit is a small wall
each cable is fully monitored for
mounted unit which can be
open, short or earth faults. Up to
distributed throughout a site and
152 outstation Exchange Units can
concealed from view in convenient
be attached to a VoCALL Network
locations such as risers, stairwells
via 19 x 8 line exchange units.
and cupboards.
The VoCALL netwrok suppots 4
master panels.

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 91


Emergency voice communications
Network exchange units

VoCALL Compact 9 Line Master


and 10 Line Slave Exchange Unit
CFVCCM9*/ CFVCCS10*

*See website for further details

Catalogue numbers
Description Code

VoCALL 8 line network master handset CFVCWM

VoCALL 8 line network exchange unit CFVCX8

VoCALL Compact 9 Line Master Unit CFVCCM9

VoCALL 10 Line Slave Exchange Unit CFVCCS10

92 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Emergency voice communications
Master exchange units (non-networkable)

Standalone master exchange units


(non-networkable)
Our range of EVCS control units cover functionality for all builds, whether small
and basic or larger and more complex. All units are fitted with EN54-4 compliant
power supplies and chargers. The EFVCC5 is our non-networkable standalone
panel for small and medium sized applications.

VoCALL Compact 5
EFVCC5

Typical applications:
The VoCALL Compact 5 Line Unit is
ideal for smaller installations which
require just a limited number of
outstations and Emergency Assist
Alarms.
The EFVCC5 is a standalone unit
containing the systems master handset,
EN54-4 approved power supply and
connectivity for the 5 outstations.
20mm knockouts are provided for all
system cabling and the housing is of
ample size to support 2x 3.2Ah backup
batteries.

NEW
PRODUCT

Features
Compact 5
Bs5839 pt9 2011 compliant 
Monitored handset 
Monitored supply and charger 
Relay outputs 
No programming 
Functional with emergency assist alarms 

Dimensions
H1 H2 W1 W2 D1 D2 W D
Dimensions (mm) (mm) (mm) (mm) (mm) (mm)
VoCALL Compact 5 surface mounted 280 - 397 - 77 -
VoCALL Compact 5 flush mounted 280 309 397 427 77 16 H

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 93


Emergency voice communications
Master exchange units (non-networkable)

Catalogue numbers

Description Code

VoCALL compact 5 line master exchange unit, non-network, EFVCC5


surface mount, graphite

VoCALL compact 5 line master exchange unit, non-network, EFVCC5-FB


flush mount, stainless steel

94 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Emergency voice communications
Devices - outstations

Outstations
For disabled refuge systems we offer a number of devices for call functions.
Outstations can offer functionality as a fire telephone or disabled refuge call
point. All outstations are available as a wall mountable unit, or with an optional
bezel to allow the product to be flush mounted.

Type A outstation Type B outstation Type B outstation Roaming handset


CFVCSHP CFVCSHF CFVCSHFG and jack plate
CFVCRJP/CFVCRHS

Typical applications: Typical applications: . Typical applications:


All builds which require a disabled Type B outstations can only be When used together, the roaming
refuge EVC system. used where the background noise handset and jack plate form a Type
is below 40dBA (therefore there A outstation. This can be used in
The Type A should be used for can be no sounder or voice alarm countries whose fire codes allow
evacuation or firefighting use. coverage in the area). for roaming handsets.
Note: (These units are not suitable
There is a weatherproof, IP65 for installation in the UK under
rated version of the Type A BS5839 Pt9.)
outstation available with a
lockable door. Please enquire for
more information.

Dimensions
W2 D1 W2 D1 W D

W1
W1
H1 H2
H1 H2 H

D2
Backbox
Backbox D2
Type A outstation Type B outstation Jack plate

Description H1 (mm) H2 (mm) W1 (mm) W2 (mm) D1 (mm) D2 (mm)


Type A outstation backbox 320 - 152 - 85 -
Type A outstation flush mounted 320 334 152 191 85 2
Type B outstation backbox 135 - 135 - 45 -
Type B outstation flush mounted 135 154 135 154 45 2
Jack plate 86 - 86 - 25 -

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 95


Emergency voice communications
Devices - outstations

Catalogue numbers

Description Code Description Code

VoCALL Type A outstation, surface mount, red CFVCSHP VoCALL Type B outstation, surface mount, stainless steel CFVCSHFSS

VoCALL Type A outstation, surface mount, stainless steel CFVCSHPSS VoCALL flush mounting bezel for use with any Type B CFVCFHB
outstation, stainless steel
VoCALL Type A outstation, flush mount, red CFVCFHP
VoCALL jack plate CFVCRJP
VoCALL Type A outstation, flush mount stainless CFVCFHPSS
VoCALL roaming handset CFVCRHS
VoCALL Type B outstation, surface mount, red CFVCSHF

VoCALL Type B outstation, surface mount, green CFVCSHFG

96 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


Emergency voice communications
Emergency assist alarm

Emergency assist alarm equipment


Emergency assist alarms are required by building regulation document M.
We offer either a stand-alone kit or a kit which integrates the Emergency Assist
equipment with our VoCALL products.

Our emergency assist alarm


kits supply everything
you need to install a fully
compliant system.

VoCALL kit Stand alone kit


This Emergency Assist Alarm - VoCALL kit has The Emergency Assist Alarm - stand alone kit
been specifically designed to integrate disabled provides the perfect solution for conformity with
call functions into the VoCALL network or VoCALL the building regulations document M and Equality
compact ranges. Act 2010.
It is fully monitored and battery backed by the The Emergency Assist Alarm - stand alone kit
VoCALL system. The Emergency Assist Alarm comprises of all the components needed to install
shows up as a call on the VoCALL system, but has a fully compliant system, with additional parts
no speech path so a conversation cannot be had available separately.
with the occupant, use of the Type B Outstations
would allow this. 4 Way Splitter
The 4 Way Splitter unit allows up to 4 stand alone
disabled toilets to be monitored in one specific
area. Staff can then, at the designated area such
as a reception or security desk, react to an alarm
swiftly and efficiently.

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 97


Emergency voice communications
Emergency assist alarm

EAA VoCALL kit


CFVCEA
Typical applications: Accessories:
Disabled Toilets.
Includes:
• Over door indicator
• Cancel button
• Pull cord unit
• Disabled sticker pack
Does not include PSU as the kit
is powered by a master unit (the
Compact 5, see p93)
Pull cord unit

EAA standalone kit


CFEAPULLKIT

Typical applications:
Disabled Toilets.
Includes:
• Power supply unit
• Over door indicator
• Cancel button
• Pull cord unit
• Disabled sticker pack
4 way splitter

Catalogue numbers
Description Code
Stand alone
Emergency assist alarm - stand alone kit CFEAPULLKIT
For use with EVC panel or 4 way splitter
Emergency assist alarm - kit without PSU CFVCEA
Accessories
4 way splitter CFEASL4
PSU for 4 way splitter CFEAPSU
Emergency assist pull cord unit CFEAPULL
Pull cord accessory pack CFEACORD
Disabled sticker (pack of 5) CFEADS

Emergency assist alarm stand alone kit, basic usage schematic

98 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018


EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 99
100 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018
Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

Addressable

P18 2 Loop Control Panel CF2000GCPD DF2000GCPD FX2000GCPD

P19 Passive Repeater Panel CF3000PRG DF6000PR FX6000PR

P19 Fire Alarm System Log Book MFALOG MFALOG MFALOG

P20 1 Loop Control Panel CF1100VDS DF6100VDS FX6100VDS

P20 2 Loop Control Panel CF1200VDS DF61002VDS FX61002VDS

P21 Add to end of product code if network card required NC NC NC

P21 Network kit (for retro fit) DF61NETKIT DF61NETKIT DF61NETKIT

P21 Passive Repeater Panel CF3000PRG DF6000PR FX6000PR

P21 Touch-Screen Repeater Panel CTPR3000 DTPR6000 DTPR6000

P21 Fire routing equipment PCB ZPCB2187FRE ZPCB2187FRE ZPCB2187FRE

P21 Fire Alarm System Log Book MFALOG MFALOG MFALOG

P22 2 Loop Control Panel CF30002G DF60002 FX60002

P22 2 Loop Control Panel, Integral Printer CF30002GP DF60002P FX60002P

P22 2 Loop Control Panel, Extended Battery CF30002GEB DF60002EB DF60002EB

P22 2 Loop Control Panel, Integral Printer, Extended Battery CF30002GPEB DF60002PEB DF60002PEB

P22 4 Loop Control Panel CF30004G DF60004 FX60004

P22 4 Loop Control Panel, Integral Printer CF30004GP DF60004P FX60004-P

P22 4 Loop Control Panel, Extended Battery CF30004GEB DF60004EB DF60004EB

P22 4 Loop Control Panel, Integral Printer, Extended Battery CF30004GPEB DF60004PEB DF60004PEB

P23 Add to end of product code if network card required NC NC NC

P23 Touch-Screen Repeater Panel CTPR3000 DTPR6000 DTPR6000

P23 Hinged Protective Cover Kit DF3000COV DF6000COV DF6000COV

P23 Network kit (for retro fit) DF6000NETKIT DF6000NETKIT DF6000NETKIT

P23 Printer kit (for retro fit) CF3000PKIT DF6000PKIT DF6000PKIT

P24 Optical Smoke Detector (CAP320, MAP820, FXN723) 400002FIRE-0002X 400002FIRE-0008X 400002FIRE-0005X

P24 Photo-Thermal Detector (CAPT340, MAOH850, FXN722) 400004FIRE-0004X 400004FIRE-0010X 400004FIRE-0007X

P24 Heat Detector (CAH330, MAH830, FXN725) 400003FIRE-0003X 400003FIRE-0009X 400003FIRE-0006X

P25 Loop connected remote indicator MRIAD MRIAD MRIAD

P25 Standard remote indicator CIR301 FX251D FX251D

P25 Weather resistant standard remote indicator CIR301WP CIR301WP CIR301WP

P25 Staff warning device CAB382 CAB382 CAB382

P26 Standard base CAB300 MAB800 FXN720

P26 Sounder base CAS380 MAS850 FXN538

P26 VAD Sounder Beacon Base (CASBB394) 666129FULL-0198X 666129FULL-0198X 666129FULL-0198X

P26 Sounder beacon base CASBB384 MASB870 FXN537

P26 Cover plate CASC CASC CASC

P26 Australian sounder base (Only for Australian Market) CAS380AU CAS380AU CAS380AU

P26 Addressable relay base MAB800R MAB800R MAB800R

P26 Base shroud BAR3000 BAR3000 BAR3000


Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

P28 Surface/Flush Callpoint CBG370S MBG813 FXN501

P28 Weatherproof Callpoint CBG370WP MBG817 FXN503

P28 Protective Hinged Cover (pack of 10) CXPC CXPC CXPC

P28 Spacer Plates (pack of 10) MBGSP MBGSP MBGSP

P28 Recessing Bezels (pack of 10) MBGBEZ MBGBEZ MBGBEZ

P28 Resettable Element Kit (pack of 10) MBGREKIT MBGREKIT MBGREKIT

P28 Spare Break Glasses (pack of 5) UBSG UBSG UBSG

P28 Callpoint Keys (pack of 10) MFBGKEY3 MFBGKEY3 MFBGKEY3

P29 Internal Wall Sounder CAS381 MAS850LPS FXN538LPS

P29 Weatherproof Wall Sounder CAS381WP MAS850LPSWP FXN538LPSWP

P29 Weatherproof wall sounder beacon CASB383-WP CASB383-WP MASB860WP

P29 Wall sounder beacon CASB383 MASB860 FXN539LPS

P29 VAD Wall Sounder Beacon CASB393 MASB880 FXN559

P29 Weatherproof VAD Wall Sounder Beacon CASB393WP MASB880WP FXN559WP

P29 Internal wall sounder bell tone CAS381B CAS381B CAS381B

P29 Weatherproof wall sounder bell tone CAS381WPB CAS381WPB CAS381WPB

P29 Australian internal wall sounder CAS381AU CAS381AU CAS381AU

P29 Australian weatherproof wall sounder CAS381WPAU CAS381WPAU CAS381WPAU

P29 VAD wall sounder beacon bell tone CASB393B CASB393B CASB393B

P29 Weatherproof VAD wall sounder beacon bell tone CASB393WPB CASB393WPB CASB393WPB

P30 Wall Sounder VAD CASB493 CASB493 CASB493

P30 Wall VAD CAB492W CAB492W CAB492W

P30 Ceiliing VAD CAB492W CAB492W CAB492W

P33 Reflective Beam Detector (50m range) MAB50R MAB50R MAB50R

P33 Reflective Beam Detector (100m range) MAB100R MAB100R MAB100R

P33 Mounting Bracket MRBFP MRBFP MRBFP

P33 Spare reflector MABR MABR MABR

P33 Duct Probe Unit MDP201 MDP201 MDP201

P34 Zone Monitor Unit CZMU352 CZMU352 CZMU352

P34 Shop Monitor Unit MSU840 MSU840 MSU840

P34 Spur Isolator Unit CSI350 CSI350 CSI350

P34 3 Channel Input/Output Unit Resets on reset CIO351 CIO351 CIO351


(recognised as 1 address)

P34 3 Channel Input/Output Unit Resets on reset CIO351SST CIO351SST CIO351SST


(recognised as 3 addresses)

P34 3 Channel Input/Output Unit Rests on silence alarms CIO351S MIO324S FXN510S

P35 230V ac Relay Unit CMIO353 CMIO353 CMIO353

P35 4 way sounder controller unit CSC354CPR CSC354CPR CSC354CPR

P35 Technical Input / Output Module CFC301 CFC301 CFC301

P36 4 Way Mimic Relay Board, 4 Inputs, 4 Outputs CIOP4 CIOP4 CIOP4

P36 8 Way Mimic Relay Board, 8 Inputs, 8 Outputs CIOP8 CIOP8 CIOP8
Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

P37 Door release module CIOP-7273 CIOP-7273 CIOP-7273

P37 FC6 Fan controller unit (surface mount) FC6 FC6 FC6

P37 FC18 Fan controller unit (rack mount) FC18 FC18 FC18

P37 4 to 20mA Interface CGI420 CGI420 CGI420

P39 Micro Zone Monitor Unit MIU872 MIU872 MIU872

P39 MCOM Micro Single Channel Output Unit (recognised as output 400010FIRE-0024X 400010FIRE-0024X 400010FIRE-0024X
unit)

P39 MCOM-S Micro Single Channel Output Unit (recognised as 400012FIRE-0026X 400012FIRE-0026X 400012FIRE-0026X
sounder)

P39 MCOM-R Micro Single Channel Output Unit (5 second reset 400011FIRE-0025X 400011FIRE-0025X 400011FIRE-0025X
pulse)

P39 MCOM--FC Micro Single Channel Output Unit (fan controller) MCOM-FC MCOM-FC MCOM-FC

P39 MCIM Micro Single Channel Input Unit 400008FIRE-0022X 400008FIRE-0022X 400008FIRE-0022X

P39 Mini module box unit (empty box) ULBU ULBU ULBU

P40 Dual-channel LonWorks BMS Interface (non handshake) EC200 EC200 EC200

P40 Dual-channel LonWorks BMS Interface (handshaking) EC200H EC200H EC200H

P40 Dual-channel LonWorks BMS Interface EC200S EC200S EC200S


(self configuring for use with EC700)

P40 Lon to RS232 Adapter EC0232 EC0232 EC0232

P40 Lon to RS232 Adapter EC0232PAVA EC0232PAVA EC0232PAVA


(for HMX PA/VA system - no handshake)

P40 Lon to RS232 Adapter EC0232PAVA3D EC0232PAVA3D EC0232PAVA3D


(for HMX PA/VA system - 3 min time delay)

P40 TCP/IP Interface EC400 EC400 EC400

P40 Lon Network Booster EC540 EC540 EC540

P40 BACnet Gateway EC650B EC650B EC650B

P40 Modbus Gateway EC700 EC700 EC700

P40 Single Mode Lon to Fibre Optic Adaptor CFSFL01 CFSFL01 CFSFL01

P40 Dual Channel Lon to Fibre Optic Adaptor CFSFL02 CFSFL02 CFSFL02

P42 Loop Splitter Unit ZPCB2222 ZPCB2222 ZPCB2222

P42 Mimic PCB (master) ZPCB2252-MML ZPCB2252-MML ZPCB2252-MML

P42 Mimic PCB (slave) ZPCB2252-MSL ZPCB2252-MSL ZPCB2252-MSL

P42 Safety Power Supply 24V / 1.5A (batteries not supplied) SPS-2423 SPS-2423 SPS-2423

P42 Safety Power Supply 24V / 2.5A (batteries not supplied) SPS-2433 SPS-2433 SPS-2433

P42 Safety Power Supply 24V / 4.5A (batteries not supplied) SPS-2453 SPS-2453 SPS-2453

P44 Graphical Visualisation Software license 1-2 panels EFGVS1-2 EFGVS1-2 EFGVS1-2
including an EC0232 interface

P44 Graphical Visualisation Software license up to 6 panels EFGVS3-6 EFGVS3-6 EFGVS3-6


including an EC0232 interface)

P44 Graphical Visualisation Software license up to 10 panels EFGVS7-10 EFGVS7-10 EFGVS7-10


including an EC0232 interface

P44 Graphical Visualisation Software license above 10 panels EFGVS11-PLUS EFGVS11-PLUS EFGVS11-PLUS
including an EC0232 interface

P44 Graphical Visualisation Software license up to 10 panels with EFGVS7-10-TCPIP EFGVS7-10-TCPIP EFGVS7-10-TCPIP
TCP/IP interlink
Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

P44 Graphical Visualisation Software license above 10 panels with EFGVS11-PLUS-TCPIP EFGVS11-PLUS-TCPIP EFGVS11-PLUS-TCPIP
TCP/IP interlink

P44 Graphical Visualisation Designer Software license - no panel EFGVS-DESIGN EFGVS-DESIGN EFGVS-DESIGN
connectivity

P44 Graphical Visualisation Premium Designer Software license EFGVS- EFGVS- EFGVS-
including an EC0232 interface PREMIUMDESGN PREMIUMDESGN PREMIUMDESGN

P44 Interface to connect panel network (LONWorks) EC0322 EC0322 EC0322


to PC (RS232)

P44 Site monitor / webserver software SITEMONITOR SITEMONITOR SITEMONITOR

P45 Loop Tester Kit LP800KIT LP800KIT LP800KIT

P45 Addressable Device Programmer CF800PROG CF800PROG CF800PROG

P45 USB panel interface USBINT2 USBINT2 USBINT2

UL Approved

P49 2 Loop Panel ULCF30002G ULDF60002G ULFX60002G

P49 2 Loop Panel, Integral Printer ULCF30002GP ULDF60002GP ULFX60002GP

P49 2 Loop Panel, Network Card ULCF30002GNC ULDF60002GNC ULFX60002GNC

P49 2 Loop Panel, Red Metal Box ULCF30002GRM ULDF60002RM ULFX60002RM

P49 2 Loop Panel, Integral Printer, Network Card ULCF30002GPNC ULDF60002GPNC ULFX60002GPNC

P49 2 Loop Panel, Integral Printer, Red Metal Box ULCF30002GPRM ULDF60002PRM ULFX60002PRM

P49 2 Loop Panel, Network Card, Red Metal Box ULCF30002GNCRM ULDF60002NCRM ULFX60002NCRM

P49 2 Loop Panel, Integral Printer, Network Card, Red Metal Box ULCF30002GPNCRM ULDF60002PNCRM ULFX60002PNCRM

P49 4 Loop Panel ULCF30004G ULDF60004G ULFX60004G

P49 4 Loop Panel, Integral Printer ULCF30004GP ULDF60004GP ULFX60004GP

P49 4 Loop Panel, Network Card ULCF30004GNC ULDF60004GNC ULFX60004GNC

P49 4 Loop Panel, Red Metal Box ULCF30004GRM ULDF60004RM ULFX60004RM

P49 4 Loop Panel, Integral Printer, Network Card ULCF30004GPNC ULDF60004GPNC ULFX60004GPNC

P49 4 Loop Panel, Integral Printer, Red Metal Box ULCF30004GPRM ULDF60004PRM ULFX60004PRM

P49 4 Loop Panel, Network Card, Red Metal Box ULCF30004GNCRM ULDF60004NCRM ULFX60004NCRM

P49 4 Loop Panel, Integral Printer, Network Card, Red Metal Box ULCF30004GPNCRM ULDF60004PNCRM ULFX60004PNCRM

P49 Rack Mounted 2 Loop Panel ULR3000L2 ULR3000L2 ULR3000L2

P49 Rack Mounted 2 Loop Panel c/w Network Card ULR3000L2NC ULR3000L2NC ULR3000L2NC

P49 Rack Mounted 4 Loop Panel ULR3000L4 ULR3000L4 ULR3000L4

P49 Rack Mounted 4 Loop Panel c/w Network Card ULR3000L4NC ULR3000L4NC ULR3000L4NC

P49 Loop repeater panel ULCF3000PRG ULDF6000PRG ULFX6000PRG

P49 Network touchscreen repeater panel ULCTPR3000 ULDPTR6000 ULFPTR6000

P50 Addressable Detector Base UCAB300 UCAB300 UCAB300

P50 Optical Smoke Detector (ULCAP320, ULMAP320, ULFX320) 400005FIRE-0011X 400005FIRE-0014X 400005FIRE-0017X

P50 Photo-Thermal Detector (ULCAPT340, ULMAPT340, ULFX340) 400006FIRE-0012X 400006FIRE-0015X 400006FIRE-0018X

P50 Heat Detector (ULCAH330, ULMAH330, ULFX330) 400007FIRE-0013X 400007FIRE-0016X 400006FIRE-0019X

P52 2 Wire Detector, Optical UCPD-2W UCPD-2W UCPD-2W

P52 2 Wire Detector, Opto-Heat UCPT-2W UCPT-2W UCPT-2W

P52 2 Wire Detector, Fixed Heat 135°F UCHT-2W UCHT-2W UCHT-2W


Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

P53 Standard Detector Base CB2E CB2E CB2E

P54 Wall Mount Horn HNR HNR HNR

P54 Ceiling Mount Horn CN128972 CN128972 CN128972

P54 Wall Mount Horn Strobe CN127249 CN127249 CN127249

P54 Wall Mount Synchronised Strobe STR STR STR

P55 Ceiling Mount Horn Strobe CN127464 CN127464 CN127464

P55 Ceiling Mounted Synchronised Strobe CN127488 CN127488 CN127488

P55 Wall Mount Outdoor Synchronised Strobe CN129013 CN129013 CN129013

P55 Ceiling Mount Outdoor Synchronised Strobe CN124338 CN124338 CN124338

P55 Exposed Conduit, Surface Mount Back Box (RED) CN109751 CN109751 CN109751

P55 Concealed Conduit Surface Mount Back Box (RED) CN109751 + CN109751 + CN109751 +
CN104486 CN104486 CN104486

P56 Single Action Pull Station UMPS-100 UMPS-100 UMPS-100

P56 Weatherpoof Single Action Pull Station UMPS-100WP UMPS-100WP UMPS-100WP

P56 Double Action Pull Station UMPS-200 UMPS-200 UMPS-200

P56 Weatherproof Double Action Pull Station UMPS-200WP UMPS-200WP UMPS-200WP

P56 Conventional Single Action Pull Station (back box ordered SG42BK2 SG42BK2 SG42BK2
seperately)

P56 Conventional Double Action Pull Station (back box ordered SG42BK1 SG42BK1 SG42BK1
seperately)

P56 Back box for conventional, surface mounting SGB32S SGB32S SGB32S

P56 Back box for conventional, weatherproof SGB-32C SGB-32C SGB-32C

P58 4 Way Sounder Controller Unit ULCSC354 ULCSC354 ULCSC354

P58 Shop Monitor Unit ULCSUM355 ULCSUM355 ULCSUM355

P58 Spur Isolator Unit ULCSI350 ULCSI350 ULCSI350

P58 3 Channel Input/Output Unit Resets on reset ULCIO351 ULCIO351 ULCIO351

P58 3 Channel Input/Output Unit Resets on silence alarms ULCIO351S ULCIO351S ULCIO351S

P58 120V/230V ac Relay Unit ULCMIO353 ULCMIO353 ULCMIO353

P58 Micro Zone Monitor Unit ULMIU872 ULMIU872 ULMIU872

P58 ULMCOM Micro Single Channel Output Unit (recognised as 400015FIRE-0029X 400015FIRE-0029X 400015FIRE-0029X
output unit)

P58 ULMCOM-S Micro Single Channel Output Unit (recognised as 400016FIRE-0030X 400016FIRE-0030X 400016FIRE-0030X
sounder)

P58 ULMCIM Micro Single Channel Input Unit (recognised as input 400013FIRE-0027X 400013FIRE-0027X 400013FIRE-0027X
unit)

P58 ULMCIM-C Micro Single Channel Input Unit (recognised as 400014FIRE-0028X 400014FIRE-0028X 400014FIRE-0028X
callpoint)

P58 Mini Module Box Unit (Empty box) ULBU ULBU ULBU

Conventional

P63 2 zone BiWire Flexi panel EFBW2ZFLEXI EFBW2ZFLEXI EFBW2ZFLEXI

P63 4 zone BiWire Flexi panel EFBW4ZFLEXI EFBW4ZFLEXI EFBW4ZFLEXI

P63 8 zone BiWire Flexi panel EFBW8ZFLEXI EFBW8ZFLEXI EFBW8ZFLEXI

P63 2 zone relays + FRE/FPE BWOB2Z BWOB2Z BWOB2Z


Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

P63 4 zone relays + FRE/FPE BWOB4Z BWOB4Z BWOB4Z

P63 8 zone relays + FRE/FPE BWOB8Z BWOB8Z BWOB8Z

P63 BiWire End of line module BWEOLM-3 BWEOLM-3 BWEOLM-3

P63 Conventional End of line module EOLM-1 EOLM-1 EOLM-1

P63 12V, 5Ah battery (1pc*) MB512 MB512 MB512

P65 2 zone BiWire Ultra panel EFBW2ZONE-NB EFBW2ZONE-NB EFBW2ZONE-NB

P65 4 zone BiWire Ultra panel EFBW4ZONE-NB EFBW4ZONE-NB EFBW4ZONE-NB

P65 8 zone BiWire Ultra panel EFBW8ZONE-NB EFBW8ZONE-NB EFBW8ZONE-NB

P65 BiWire End of line module BWEOLM-3 BWEOLM-3 BWEOLM-3

P65 Repeater panel EFBWREPEATER EFBWREPEATER EFBWREPEATER

P65 12V, 5Ah battery (1pc*) MB512 MB512 MB512

P67 BiWire Ultra wall sounder EF009 EF009 EF009

P67 BiWire Ultra wall sounder, weatherproof EF009WP EF009WP EF009WP

P67 BiWire Ultra wall sounder VAD EF009SB EF009SB EF009SB

P67 BiWire Ultra wall sounder VAD, weatherproof EF009SBWP EF009SBWP EF009SBWP

P67 BiWire Ultra base sounder first fix EF5021BWS EF5021BWS EF5021BWS

P67 BiWire Ultra base sounder VAD first fix EF5021BWSB EF5021BWSB EF5021BWSB

P67 BiWire Ultra Slim Base sounder with cover EF5023S EF5023S EF5023S

P67 BiWire Ultra detector 5 in 1 EFBW5IN1DET EFBW5IN1DET EFBW5IN1DET

P67 Optical BiWire detector EFBWOPTDET EFBWOPTDET EFBWOPTDET

P67 BiWire Ultra callpoint EF201BWCP EF201BWCP EF201BWCP

P67 BiWire callpoint, weatherproof EF203BWCPWP EF203BWCPWP EF203BWCPWP

P67 8 Zone Conventional Panel (no battery) EFCV8Z(-NB) EFCV8Z(-NB) EFCV8Z(-NB)

P69 End of Line Module EOLM-1 EOLM-1 EOLM-1

P69 8 Zone Relays + FRE/FPE BW0B8Z BW0B8Z BW0B8Z

P69 12V, 5Ah battery (1pc*) MB512 MB512 MB512

P71 Conventional 2 Zone Panel (no battery) FX2202CPD(-NB) FX2202CPD(-NB) FX2202CPD(-NB)

P71 Conventional 4 Zone Panel (no battery) FX2204CPD(-NB) FX2204CPD(-NB) FX2204CPD(-NB)

P71 Steel back box (for use with FX2202/4/8) FX22003300 MB FX22003300 MB FX22003300 MB

P71 Repeater Panel FXRP2200 FXRP2200 FXRP2200

P71 Fire Alarm System Log Book MFALOG MFALOG MFALOG

P71 12V 3.2Ah SLA MB3A212 MB3A212 MB3A212

P73 16 Zone Control Panel CF50016 CF50016 CF50016

P73 Fire Alarm System Log Book MFALOG MFALOG MFALOG

P73 16 Zone Control Panel EFCV16Z-NB EFCV16Z-NB EFCV16Z-NB

P73 12V 4Ah SLA battery MB412 MB412 MB412

P75 5 in 1 Multi-Mode Detector FXN922 400017FIRE-0031X 400017FIRE-0031X

P75 Optical Smoke detector CPD321 MPD821 FXN533

P75 Photo-Thermal detector CPT341 MPT951 FXN632

P75 Rate of rise heat detector CFR330 MFR830 FXN525


Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

P75 Fixed Heat detector 77°C CMT360 MMT860 FXN524

P75 Fixed Heat detector 92°C CHT390 MHT890 FXN526

P75 Remote Indicator CIR301 FX251D FX251D

P75 Weatherproof Remote Indicator CIR301WP CIR301WP CIR301WP

P76 Standard Base CDBB300 CDB300 FXN520

P76 Relay Base FXN520R FXN520R FXN520R

P76 Reflective Beam Detector (50m range) MBD50R MBD50R MBD50R

P76 Reflective Beam Detector (100m range) MBD100R MBD100R MBD100R

P76 Mounting Bracket MRBFP MRBFP MRBFP

P77 Duct Probe MDP201 MDP201 MDP201

P78 Surface/Flush Callpoint CX201 MBG914 FX201

P78

P78 Excellence and


Weatherproof Callpoint

Protective Hinged Cover (pack of 10)


CX203

CXPC
MBG917

CXPC
FX203

CXPC

P78

P78 innovation in fire


Spacer Plates (pack of 10)

Recessing Bezels (pack of 10)


MBGSP

MBGBEZ
MBGSP

MBGBEZ
MBGSP

MBGBEZ

P78

P78

P78
safety solutions
Resettable Element Kit (pack of 10)

FX5G Spare Break Glasses (pack of 10)

Earth Continuity Links (pack of 5)


MBGREKIT

FX5G

MBG119
MBGREKIT

FX5G

MBG119
MBGREKIT

FX5G

MBG119

P78 MFBGKEY3 Callpoint Keys (pack of 10) 4990009FUL-0040 4990009FUL-0040 4990009FUL-0040

P79 FX006 Internal 6 Inch Bell FX006 FX006 521601FULL-1601

P80 FX003 Flush Sounder, Red 550001FULL-0001X 550001FULL-0001X FX003

P80 FX003W Flush Sounder, White 550015FULL-0017X 550015FULL-0017X FX003W

P80 MFSSBB Back Box For FX003, Red 591001FULL-0016 591001FULL-0016 MFSSBB

P80 FX002SB Low Profile Surface Sounder, Red FX002SB FX002SB FX002SB

P80 FX002DB Weatherproof Surface Sounder, Red FX002DB FX002DB FX002DB

P80 FX007 High Output Wall Sounder 651004FULL-0009X 651004FULL-0009X FX007

P80 MLC624 Low Current Wall Sounder 650001FULL-0003X 650001FULL-0003X 650001FULL-0003X

P80 FXN824 Base Mountable Sounder 666058FULL-0098X 666058FULL-0098X MDS824

P80 MDS824COV Blanking Plate for MDS824 (pack of 5) 590037FULL-0305 590037FULL-0305 MDS824COV

P82 FXSOLWRS Solista Wall Red Body Shallow Base 812013FULL-0237X 812013FULL-0237X FXSOLWRS

P82 FXSOLWRD Solista Wall Red Body Deep Base 812005FULL-0107X 812005FULL-0107X FXSOLWRD

P82 FXSOLCWS Solista LX Ceiling 812022FULL-0123X 812022FULL-0123X FXSOLCWS

P82 FXROLPWR RoLP Wall Red Body Base & Sounder 8500025FULL-0025X 8500025FULL-0025X FXROLPWR

P82 FXROLPWR-B RoLP Wall Red Body Base 8500040FULL-0219X 8500040FULL-0219X FXROLPWR-B

P82 FXSYG1WR Symphoni LX Wall Red Body 8500045FULL-0233X 8500045FULL-0233X FXSYG1WR

P82 FXSYR-B Symphoni LX Wall Base Red Body 8500095FULL-0231X 8500095FULL-0231X FXSYR-B

P82 FXSYG1WR-WP Symphoni LX Wall Weatherproof Red Body 8500050FULL-0249X 8500050FULL-0249X FXSYG1WR-WP

P82 FXSYR-B-WP Symphoni LX Wall Weatherproof Base Red Body 8500100FULL-0247X 8500100FULL-0247X FXSYR-B-WP

P82 Deep base for Solista LX Ceiling FX000WWP FX000WWP FX000WWP

P84 MLB124SB Low Profile LED indicator 811012FULL-0006 811012FULL-0006 MLB124SB


Product code cross reference

Page
No. Description Cooper Code Menvier Code JSB Code

P84 MLB124DB Weatherproof LED Beacon 811013FULL-0007 811013FULL-0007 MLB124DB

P84 FL-RL-R-S Conventional xenon sounder indicator FL-RL-R-S FL-RL-R-S FL-RL-R-S

P84 FL-RL-R-D Weatherproof IP65 xenon sounder indicator 640031FULL-0111X 640031FULL-0111X FL-RL-R-D

P86 Mains Powered Heavy Duty Door Retainer MDR240 MDR240 MDR240

P86 24V dc Heavy Duty Door Retainer MDR24L MDR24L MDR24L

P86 Floor Mounting Bracket for Heavy Duty Door Retainers ZMDRFBB ZMDRFBB ZMDRFBB

P86 24V dc Compact Door Retainer FX02124VLC FX02124VLC FX02124VLC

P86 Mains Powered Compact Door Retainer FX021240LC FX021240LC FX021240LC

P86 Floor Mounting Bracket for Compact Door Retainers FX021LCFB FX021LCFB FX021LCFB

P86 Spare Striker Plate For Either Magnet ZMDRSWIV ZMDRSWIV ZMDRSWIV

P86 Heavy Duty Relay Unit MAR724 MAR724 MAR724

P87 Safety Power Supply 24V / 1.5A (batteries not supplied) SPS-2423 SPS-2423 SPS-2423

P87 Safety Power Supply 24V / 2.5A (batteries not supplied) SPS-2433 SPS-2433 SPS-2433

P87 Safety Power Supply 24V / 4.5A (batteries not supplied) SPS-2453 SPS-2453 SPS-2453

P88 Optical / Acoustic sign boards 5945-CSA 5945-CSA 5945-CSA

Emergency Voice Communications and Emergency Assist Alarms

P91 VoCALL 10 Line Networkable Master System Handset CFVCWM CFVCWM CFVCWM

P91 VoCALL 8 Line Network Exchange Unit CFVCX8 CFVCX8 CFVCX8

P92 VoCALL Compact 9 Line Master Unit CFVCCM9 CFVCCM9 CFVCCM9

P92 VoCALL 10 Line Slave Exchange Unit CFVCCS10 CFVCCS10 CFVCCS10

P93 VoCall Compact 5 Line Master Exchange Unit, Graphite EFVCC5 EFVCC5 EFVCC5

P93 VoCall Compact 5 Line Master Exchange Unit, Stainless Steel EFVCC5-FB EFVCC5-FB EFVCC5-FB

P95 VoCall Type A Outstation, Surface Mount, Red CFVCSHP CFVCSHP CFVCSHP

P95 VoCall Type A Outstation, Surface Mount, Stainless Steel CFVCSHPSS CFVCSHPSS CFVCSHPSS

P95 VoCall Type A Outstation, Flush Mount, Red CFVCFHP CFVCFHP CFVCFHP

P95 VoCall Type A Outstation, Flush Mount, Stainless Steel CFVCFHPSS CFVCFHPSS CFVCFHPSS

P95 VoCall Type B Outstation, Surface Mount, Red CFVCSHF CFVCSHF CFVCSHF

P95 VoCall Type B Outstation, Surface Mount, Green CFVCSHFG CFVCSHFG CFVCSHFG

P95 VoCall Type B Outstation, Surface Mount, Stainless Steel CFVCSHFSS CFVCSHFSS CFVCSHFSS

P95 VoCall Flush Mounting Bezel Type B Outstation, Stainless Steel CFVCFHB CFVCFHB CFVCFHB

P95 VoCall Jack Plate CFVCRJP CFVCRJP CFVCRJP

P95 VoCall Roaming Handset CFVCRHS CFVCRHS CFVCRHS

P98 Emergency assist alarm - stand alone kit CFEAPULLKIT CFEAPULLKIT CFEAPULLKIT

P98 Emergency assist alarm - kit without PSU CFVCEA CFVCEA CFVCEA

P98 4 way splitter CFEASL4 CFEASL4 CFEASL4

P98 PSU for 4 way splitter CFEAPSU CFEAPSU CFEAPSU

P98 Emergency assist pull cord unit CFEAPULL CFEAPULL CFEAPULL

P98 Pull cord accessory pack CFEACORD CFEACORD CFEACORD

P98 Disabled sticker (pack of 5) CFEADS CFEADS CFEADS


Spring Mews
London, UK
Introduction Contact details
Section Name Sales and technical support

Contact

Eaton Sales Service Online Resources


Eaton Electrical Systems Ltd T: +44 (0)1633 628 566 T: +44 (0)1302 303 352
Wheatley Hall Road Visit www.uk.eaton.com for the
F: +44 (0)1302 367 155 F: +44 (0)1302 303 332 following resources:
Doncaster E: [email protected] E: [email protected]
South Yorkshire
DN2 4NB • 24/7 online product support
Technical Export • Catalogue and literature
United Kingdom
www.cooperfire.com T: +44 (0)1302 303 350 T: +44 (0)1302 303 344 • Product profiles
www.uk.eaton.com F: +44 (0)1302 303 332 F: +44 (0)1302 303 345 • Datasheets, installation and
E: [email protected] user manuals
E: [email protected]

110 EATON
EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018
EATON - FIRE
- FIRE AND
AND VOICE
VOICE ALARM
ALARM SYSTEMS
SYSTEMS CF-CC2556
2014 January
CF-CC2556 June 2018
2014 110
Notes

EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 111
At Eaton, we’re energized by the challenge of powering a world
that demands more. With over 100 years experience in electrical
power management, we have the expertise to see beyond today.
From groundbreaking products to turnkey design and engineering
services, critical industries around the globe count on Eaton.
We power businesses with reliable, efficient and safe electrical
power management solutions. Combined with our personal
service, support and bold thinking, we are answering tomorrow’s
needs today.
Follow the charge with Eaton, visit eaton.eu

Eaton
Electrical Sector EMEA
Route de la Longeraie 7
1110 Morges, Switzerland

Eaton
Eaton Electrical Systems Ltd.
Wheatley Hall Road
Doncaster
South Yorkshire
DN2 4NB
United Kingdom
Tel: +44 (0)1302 303 999
Fax: +44 (0)1302 303 333
Email: [email protected]
Web: w ww.cooperfire.com
www.uk.eaton.com

© 2018 Eaton
All Rights Reserved
Pub Reference: CF-CC2556 / CSSC-910
April 2018