Design and installation of a fire detection system can often be a complex
process, with each project often bringing its own challenges in making sure the
system is compliant, reliable and easy to operate. Our team of engineers will
partner with your project management team using our expertise to meet the
specific requirements of your project.
Eaton has a great deal of experience handling major projects across the
globe. We can help not just with the product and technical support but also by
providing guidance and advice to specifiers and project management teams on
topics such as standards and regulations.
We are BAFE SP203 certified for design, commissioning and maintenance of
fire detection systems, giving our customers the peace of mind they need that
our systems conform with all necessary safety requirements.
Technical support
Our dedicated technical support team are able to offer customers around the
world advice and guidance on a wide variety of technical matters via telephone
or email. In the vast majority of cases, a process of systematic questioning
enables the team to diagnose the challenge and advise the customer on the
appropriate solution.
Sometimes more detailed troubleshooting and analysis methods may be
used to determine the actual requirements and the best way of resolving it.
If necessary, the technical support team will also call on the knowledge and
expertise of Eaton’s product management, R&D and design departments to
help resolve the customer’s issue.
In addition, the technical support team can provide customers with assistance
on product information, installation and operating instructions, and the
legislative requirements of your fire detection systems.
Contents
1. Introduction
An introduction to fire systems 10
Conventional and two-wire systems 12
Addressable systems 13
Emergency voice communication systems 14
UL listed fire systems 15
Voice alarm systems 15
6. Appendix
Part code lookup 102
Contact details 111
In the event of a detector or call point being triggered, the By combining both the detection and the alarm annunciation
panel is able to identify which circuit contains the triggered wiring into a single circuit, considerable savings in installation
device and thereby indicate which zone the fire alarm has time and cabling can be achieved.
come from. The indicated zone can then be manually searched
to locate the triggered device. Eaton's BiWire Flexi panel combines two technologies so that
it can be configured to allow either two-wire or conventional
With this type of functionality a conventional system is best devices to work on a zone. This flexibility means it can be easily
used in smaller builds where it wouldn’t be difficult to locate incorporated into system extensions or used as part of a
the triggered device in a given zone. new system.
Zone 1 Zone 2
Zone 3 Zone 4
Zone 1 Zone 2
15 16 1 2
14 3
13 4
12 5
11 6
10 9 8 7
Zone 3 Zone 4
Contents
Intelligent addressable systems
Panels
Devices
CF2000GCPD
Intelligent addressable control panel
AT
PREVEN
LPCB
ION BO
A
S
R
LO D
Intelligent addressable systems
CF2000GCPD
24V dc output
D
Description Code
Intelligent addressable 2 loop control panel CF2000GCPD
Standard repeater panel CF3000PRG
Fire alarm system log book MFALOG
CF1100VDS
Intelligent addressable control panel
“The simplicity of
operation, powerful
cause and effect
programming capability
and competitive pricing
make the system
suitable for a wide
range of small to
medium sized projects.”
Dimensions
D W
Catalogue numbers
Description Code
1 loop control panel CF1100VDS
2 loop control panel CF1200VDS
Add to end of product code if network card required NC
Add to end of product code if dual redundancy NCDR
network card required
Network kit (for retro fit) DF61NETKIT
Passive repeater panel CF3000PRG
Touch-screen repeater panel CTPR3000
Fire routing equipment PCB ZPCB2187FRE
Fire alarm system log book MFALOG
CF3000
Intelligent addressable control panel
AT
PREVEN
LPCB
ION BO
A
S
R
LO D
Intelligent addressable systems
CF3000
Detectors
Our addressable range has multiple options for intelligent addressable
detectors. All detectors are designed for optimum functionality in mid-large
sized builds. They are all soft addressed and have integral short circuit isolators.
We also offer a loop connected remote indicator, designed to offer discreet
remote indication and an ability to monitor multiple detectors. This helps to
minimise wiring requirements.
Typical applications: Typical applications: Typical applications: *The CAPT340 has day/
night modes available,
Suitable for most applications. Responds quickly to fast clean Environments where the ambient programmeable from the site
burning fires. conditions might cause false installer software. The day
Fastest response to slow alarms with smoke detectors.
burning or smouldering fires Maintains the advantage of mode uses the heat aspect of
which give rise to large visible optical detectors when detecting Examples include areas with high the detector for areas which
smoke particles. smouldering fires. levels of dust or fumes. may have smoky environments
during, for example working
The CAH330 can operate in 3 hours. The night mode uses a
modes: rate of rise, fixed heat combination of A2S and smoke
77°C and fixed heat 90°C. detection. If not programmed,
the detector defaults to dual
These modes are set by mode.
the panel.
Dimensions Performance
Dia
Feature CAP320 CAPT340 CAH330 CAH330 CAH330
ERTI
N C F
IO I
C
T
AT
PREVEN
24 LPCB
ION BO
A
S
R
LO D
Intelligent addressable systems
Devices - indicators
Indicators
Our indicators are designed as additional indication devices when detectors
have been triggered. These products are designed to be used as indicators only,
and not visual alarm devices (see p26 and 29 for EN54-23 certified VADs).
Description Code
W
Dia
Diameter
Description (mm) Depth (mm)
Staff warning device 101 33
Height
Description (mm) Width (mm) Depth (mm)
Remote indicators 87 87 30
Bases
We stock a variety of bases, providing a wide functionality for different
situations. The standard base (CAB300) provides a foundation for our
addressable detectors. The range of bases also includes capability for additional
sounder and sounder beacon operation. Both our sounder base (CAS380) and
VAD sounder beacon base (CASBB394) can be used as standalone devices
when fitted with our cover plate (CASC).
0.5Hz
FLASH
CASBB384
The CASBB384 sounder beacon
base is also available for indication
purposes, where EN 54-23 is not
a requirement.
Features
CAB300 CAS380 CASBB384 CASBB394
First fix base
Selectable tones
ERTI
N C F
IO I
C
T
AT
PREVEN
26 LPCB
ION BO
A
S
R
LO D
Intelligent addressable systems
Accessories - bases
Performance
CAS380 CASBB384 CASBB394
Sound output
Low volume 84dB at < 4mA 83dB @ <6.6mA 83dB at < 8.6mA
Medium volume 92dB at < 8mA 90dB @ <8mA 90dB at < 10mA
High volume 95dB at < 12mA 93dB @ <9mA 93dB at < 11mA
Dimensions
Dia
D D
D
Dia Dia
Catalogue numbers
Description Code
Callpoints
Two versions of the intelligent addressable callpoint are available, the surface/
flush mounted CBG370S or the weatherproof CBG370WP. Both have an
integral short circuit isolator and are very simple to install. The callpoints are
packaged with 2 frangible glass elements and test key, with a comprehensive
range of further accessories available.
ERTI
N C F
IO I
C
T
AT
PREVEN
28 LPCB
ION BO
A
S
R
LO D
Intelligent addressable systems
Devices - wall sounders
CASB393WP CASB383-WP D
H H
0.5Hz
FLASH
AT
PREVEN
LPCB
ION BO
A
S
R
LO D
Intelligent addressable systems
Devices - wall sounders
NEW
PRODUCT
Typical applications:
Wall sounder VAD Wall sounder VAD
This EN 54-23 compliant sounder (weatherproof)
beacon visual alarm device (VAD)
is suitable for fire notification Description H (mm) W (mm) D (mm)
in commercial buildings. The
weatherproof variant, with an Wall sounder VAD 147 106 92
IP66 ingress protection rating, Wall sounder VAD 151 111 100
can be used in wet and outdoor (weatherproof)
environments.
Red (CASB483/WP) or white
(CASB493/WP) flash options
available.
NEW
PRODUCT
Typical applications:
Wall VAD (shallow base) Wall VAD (deep base)
A low-profile, low-current solution
to the latest EN 54-23 fire
standard, this fire alarm beacon
Description H (mm) W (mm) D (mm)
VAD. It is also compatible with a
range of bases making it suitable Wall VAD (shallow base) 93 93 38
for a variety of applications.
Wall VAD (deep base) 93 93 67
Red (CAB482W) or white
(CAB492W) flash options
available.
-
Ceiling VAD Dimensions
CAB492CS/CAB482CS
NEW
PRODUCT
Typical applications:
Ceiling VAD
This EN 54-23 certified, low-
current fire alarm beacon is
suitable for ceiling mounting. It is Description H (mm) W (mm) D (mm)
compatible with a shallow base Ceiling VAD 93 93 38
providing flexibility as to where
the VAD can be installed.
Red (CAB492CS) or white
(CAB482CS) flash options
Catalogue numbers
Description Code Description Code
Wall sounder VAD, red, white flash 8500110FULL-0199X Wall VAD, red, white flash, deep base 812034FULL-0210X
Wall sounder VAD, red, red flash 8500111FULL-0197X Wall VAD, Wall VAD, red, red flash, shal¬low base 812035FULL-0211X
Wall sounder VAD, red, white flash, waterproof 8500114FULL-0200X Wall VAD, Wall VAD, red flash, deep base 812036FULL-0212X
Wall sounder VAD, red, red flash, waterproof 8500115FULL-0201X Ceiling VAD, red, white flash, shallow base 812050FULL-0269X
Wall VAD, red, white flash, shallow base 812033FULL-0209X Ceiling VAD, red, red flash, shallow base 812037FULL-0214X
H D
Features Features
MAB50R MAB100R
Operating range 5 to 50 metres 50 to 100 metres Duct width range 300mm to 1500mm
5 to 50 metres
Tolerance to beam misalignment Detector ± 0.8˚, Detector ± 0.8˚,
at 35% Prism ± 5.0˚ Prism ± 5.0˚ Duct air speed range 1m/s to 20m/s
Detector ± 0.8˚
Fire alarm thresholds 2.50dB (25%) 2.50dB (25%) Prism ± 5.0˚
3.74dB (35%) 3.74dB (35%)
6.02dB (50%) 6.02dB (50%) Temperature range -20°C or +60°C
Optical wavelength 880nm 880nm Optical wavelength 880nm
Interfaces
We supply an extensive range of interfaces to support our control panels.
Interfaces allow for a wide variety of installations to be simplified without the
use of specialist or customised equipment. For assistance deciding which
interfaces will benefit you the most, contact our technical support team at
[email protected]
Zone monitor unit Spur isolator unit Shop monitor unit 3 channel I/O unit
CZMU352 CSI350 MSU840 CIO351
Description H (mm) W (mm) D (mm) 3 channel input/output unit resets on silence alarms CIO351S
Interfaces continued
4 way sounder controller unit
CSC354CPR
Typical applications:
The 4 way sounder controller unit (CSC354CPR) adds functionality
to your addressable panel by powering up to 4 lines of conventional
output devices.
The CSC354CPR gives access to Eaton’s extensive range of
conventional devices, including EN54-23 certified VADs, beacons,
signboards, bells and sounders.
It is ideal in situations where there is a requirement for devices with
a high current draw or where conventional sounder circuits are in a
remote location away from the fire alarm control panel.
Typical applications:
These addressable mimic relay boards (CIOP4) and (CIOP8) are 4 and 8
way soft addressing output modules, incorporating integral short circuit
isolators.
The units are suitable for switching low voltage (24V dc at 1A
maximum), via a set of latching relay contacts.
The flexibility of these modules is further enhanced by the fact that
each output can be programmed for a range of triggers such as
disablement, fault, fire, test panel, test zone prealarm, fire routing
equipment, fire protecting equipment and reset with up to 16 different
trigger sources per output.
These units have an additional 4 inputs which can initiate a reset,
silence, evacuate and test function.
Mimic relay
Typical applications:
The CIOP-7273 door release module allows addressable systems
to comply with the demands of class A doors and their release in
the event of the full range of scenarios as detailed in BS7273-4
standard the code of practice governing door holders and door release
mechanisms in the UK .
The units are 2 way soft addressed output modules that incorporate
integral short circuit isolators. They are suitable for switching low
voltage (24V DC @ 2A maximum) via a set of non-latching
relay contacts.
Compatible with the current range of Eaton intelligent addressable
control panels, their flexibility is further enhanced by the fact that each
output can be programmed for the full range of triggers required by
BS7273-4 such as disablement, fault and fire with additional triggers of
pre-alarm, fire routing equipment, fire protecting equipment. The trigger
source can be global, by panel, by loop, by zone or by address.
Units can be programmed using Eaton Site Installer software via the
RS232 port; external power is required for these modules.
Typical applications:
FC18 and FC6 fan controller units work in conjunction with the Eaton's
range of intelligent addressable control panels, providing the capability
to control and display the status of AHU fans.
The units are connected to the control panel by means of the comms
loop, utilizing only one address whilst providing the ability to monitor
and control up to 18/6 AHU fans. Each FC18 and FC6 unit incorporates
its own CPU specifically configured to control the relevant input and
output logic making programming quick and easy using Eaton site
installer software.
Recently upgraded to be compatible with new Smoke Management
protocols. Both FC6 and FC18 are ideal for use in conjunction with
updated CF3000 panels and the new MCOM-FC interface module.
FC6 Fan controller unit (surface mount) FC18 Fan controller unit (rack mount)
Micro zone Micro single channel Micro single channel MCOM variants
monitor unit input unit output unit The MCOM-R gives a 5 second
MIU872 MCIM MCOM pulse on reset, and is used
for connecting/resetting beam
Typical applications: Typical applications: Typical applications: detectors.
The micro zone monitor The micro single channel input The micro single channel output The MCOM-S is identified by
unit (MIU872) is suitable for unit (MCIM) is suitable for unit (MCOM) is suitable for the panel as a sounder and does
interfacing a zone of up to 20 monitoring a set of normally switching low voltage (24V dc at not reset when put into 'silence'
conventional detectors onto an open, volt free contacts such as 1A maximum), via a set of non mode, only resets once panel has
intelligent addressable control sprinkler system flow switches latching relay contacts. been reset.
panel. and auxiliary panel fire/fault The MCOM-FC is identified by the
signals. Other examples include It is also suitable for switching
It will operate with any HVAC control circuits, plant panel as a sounder. It will activate
non-fire input signals such as flow from its associate cause and
conventional detector in valve open contacts, generator shutdown control circuits, fire
configuration with a schottky door closure etc. effect programming. It will reset
start up, fire door closed etc. from a global reset not a global
diode type base (CDBB300).
silence command. Suitable for
use with fan controller devices for
smoke management.
Catalogue numbers
Description Code
Network interfaces
Eaton offer multiple network interfaces which allow our panels and devices a
wider variety of functionality. These network interfaces allow the connection of
the Eaton network system to a computer network, and PC based applications
such as site monitor, site graphic and web server.
Lon to RS232 adaptor Dual-channel LonWorks TCP/IP interface Lon network booster
EC0232 BMS interface EC400 EC540
EC200
LonWorks
LonWorks Bus
LonWorks Bus
LonWorks Bus
BACnet gateway Modbus gateway Single mode Lon to Dual channel Lon to
EC650B EC700 fibre optic adapter fibre optic adapter
CFSFL01 CFSFL02
Catalogue numbers
Dual-channel lonworks BMS interface (non handshake) EC200 TCP/IP interface EC400
Dual-channel lonworks BMS interface (handshaking) EC200H Lon network booster EC540
Ancillaries
A range of ancillaries are available to complement and extend the capability of
our existing hardware.
Catalogue numbers
Description Code
Software
Eaton offer a number of specialised programs to aid with the installation,
maintenance, functionality and servicing of our addressable systems. Installed
using the USB analogue systems panel interface (see p45) and a PC or
laptop, these software programs help to solidify our addressable systems'
capabilities and make it easier for users to control and organise the system on
their site.
Testing equipment
As well as offering complete fire systems, Eaton can also provide testing
equipment to ease the process of installation, commissioning, maintenance
and fault finding.
Catalogue numbers
Description Code
UL Systems
Underwriters Laboratories Inc. (UL) is an Shangri-la at the Fort and Times Square projects in
independent product safety certification South East Asia and several major projects in the
organisation, established in 1894, to develop Middle East including a major projects within the
standards and test procedures for products, prestigious Riyadh Financial District in the Kingdom
materials, components, assemblies, tools and of Saudi Arabia.
equipment. Chiefly dealing with product safety
The Eaton UL range is designed to provide a
it also evaluates and certifies the efficiency of
solution for all sizes of project, from the simple
a company’s business processes through its
small stand alone system to the large multi
magnificent system registration programs.
panel networked system with PA/VA and BMS
Since the launch of our UL Listed fire product integration.
range, several prestigious projects worldwide have
been supplied including Hyatt Resort and Spa,
Contents
UL listed fire systems range
Panels
Devices
SIGNALING
4AC5
FIRE ALARM
EQUIPMENT
ULCF3000 series
UL listed control panels
4AC5
FIRE ALARM
EQUIPMENT
Dimensions
D2
D2
W
W
H
H
D1
D1
Description H (mm) W (mm) D1 (mm) D2 (mm)
ULCF3000 397 497 75 130
ULCF3000RM 398 505 48 118
Catalogue numbers
Description Code Description Code
2 loop panel ULCF30002G 4 loop panel, integral printer, red metal box ULCF30004GPRM
4 loop panel ULCF30004G 2 loop panel, network card, red metal box ULCF30002GNCRM
2 loop panel, integral printer ULCF30002GP 4 loop panel, network card, red metal box ULCF30004GNCRM
4 loop panel, integral printer ULCF30004GP 2 loop panel, integral printer, network card, ULCF30002GPNCRM
red metal box
2 loop panel, network card ULCF30002GNC
4 loop panel, integral printer, network card, ULCF30004GPNCRM
4 loop panel, network card ULCF30004GNC red metal box
2 loop panel, integral printer, network card ULCF30002GPNC Rack mounted 2 loop panel ULR3000L2
4 loop panel, integral printer, network card ULCF30004GPNC Rack mounted 4 loop panel ULR3000L4
2 loop panel, red metal box ULCF30002GRM Rack mounted 2 loop panel c/w network card ULR3000L2NC
4 loop panel, red metal box ULCF30004GRM Rack mounted 4 loop panel c/w network card ULR3000L4NC
2 loop panel, integral printer, red metal box ULCF30002GPRM Loop connected repeater panel ULCF3000PRG
Touchscreen network repeater panel ULCTPR3000
Detectors
Our UL range has multiple options for intelligent addressable detectors. All
detectors are designed for optimum functionality in mid-large sized builds. They
are all soft addressed and have integral short circuit isolators.
SIGNALING
4AC5
UL intelligent addressable systems
Devices - detectors
Performance
Heat Class ULCAP320 ULCAPT340 ULCAH330
Heat element rating N/A 135°F ROR + Fixed 135°F, Fixed 135°, Fixed 194°F
Dimensions
Dia
D1
D2
Catalogue numbers
Description Code
Detectors
Our UL range has multiple options for conventional detectors. All detectors
have a removable detector chamber and drift compensation. The range of
detectors for different applications allow for all build requirements to be met.
As there is no UL certified conventional panel a ULMIU872 micro interface
(p59) is required in conjunction with a UL intelligent addressable panel to
use conventional detectors.
Performance
Heat class UCPD-2W UCPT-2W UCHT-2W
Mounting position Ceiling in open areas Ceiling in open areas Ceiling in open areas
SIGNALING
4AC5
UL intelligent addressable systems
Devices - conventional detectors
Conventional
detector base
CB2E
Typical applications:
The CB2E has been specifically
designed for compatibility with
our UL range of conventional
detectors. It can be be used
in all builds with conventional
detectors.
Wall mount horn Ceiling mount horn Wall mount horn Ceiling mount horn
HNR CN128972 strobe/synchronised strobe/synchronised
strobe strobe
CN127249/STR CN127464/CN127488
Dimensions
Dia D
W W D D
SIGNALING
4AC5
UL intelligent addressable systems
Devices - horns and strobes
Typical applications:
The outdoor synchronised strobes are UL certified to meet adverse
weather conditions. They are perfect for builds where outdoor
indication is required.
These units use a universal, common mounting base making them
ideal for retrofit jobs, limited space environments and pre-existing wire
configurations.
W D
Description Code
Description H (mm) W (mm) D (mm) WPSBB -R Exposed conduit, surface mount CN109751
back box (RED)
RSSWP* 131 131 110
WPSBB-R + WP-KIT Concealed conduit surface CN109751 + CN104486
*Both wall mount and ceiling mount variants
mount back box (RED)
Pull stations
The addressable pull stations are constructed of high quality, die cast metal for
long lasting performance. The range consists of the UL listed MPS range of pull
stations and the UL listed fast response input initiating module (ULMCIM-C).
D
Description Code
Single action pull station, supplied with back box (addressable) UMPS-100
H (mm) W (mm) D (mm) Back box for conventional, surface mounting SGB32S
SIGNALING
4AC5
UL intelligent addressable systems
Product Name
Interfaces
We supply an extensive range of interfaces to support our UL control panels.
Interfaces allow for a wide variety of installations to be simplified without the
use of specialist or customised equipment. For assistance deciding which
interfaces will benefit you the most, contact our technical support team;
[email protected]
4 Way Sounder Shop monitor unit Spur isolator unit 3 channel I/O unit
Controller Unit ULCSUM355 ULCSI350 ULCIO351
ULCSC354
H
H
W
Typical applications: W
SIGNALING
4AC5
UL intelligent addressable systems
Devices - micro interfaces
Micro interfaces
Whilst our standard UL interfaces are designed to be installed in the position
required on the loop, our range of micro interfaces can sit within a panels’
enclosure.
W H
Catalogue numbers
4 way sounder controller unit ULCSC354 ULMCOM Micro single channel output unit ULMCOM
(recognised as output unit)
Shop monitor unit ULCSUM355
ULMCOM-S Micro single channel output unit ULMCOM-S
Spur isolator unit ULCSI350 (recognised as sounder)
3 Channel input/output unit resets on reset ULCIO351 ULMCIM Micro single channel input unit ULMCIM
(recognised as input unit)
3 Channel input/output unit rests on silence alarms ULCIO351S
ULMCIM-C Micro single channel input unit ULMCIM-C
120V/230V ac relay u.nit ULCMIO353 (recognised as callpoint)
Micro zone monitor unit ULMIU872 Mini module box unit (empty box) ULBU
SIGNALING
4AC5
60 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018
Two-wire and conventional systems
Contents
Contents
Two-wire and conventional fire systems
Two-wire and conventional fire system
Conventional panels
Conventional devices
Detectors and indicators 74 Bases 76 Beam detectors 76
EFBW series
BiWire Flexi control panel
Description Code
2 zone BiWire Flexi panel* EFBW2ZFLEXI
4 zone BiWire Flexi panel* EFBW4ZFLEXI
8 zone BiWire Flexi panel* EFBW8ZFLEXI
2 zone relays + FRE/FPE BWOB2Z
4 zone relays + FRE/FPE BWOB4Z
8 zone relays + FRE/FPE BWOB8Z
BiWire repeater panel* EFBWCV-REPEATER
BiWire End of line module BWEOLM-3
Conventional End of line module EOLM-1
12V, 5Ah battery (1pc*) *2 required MB512
H (mm) W (mm) D (mm) * Panels are shipped without batteries inside them. Batteries should be
ordered separately.
Complete Panel 336 375 134
Back Box 273 338 88-
EFBW series
BiWire Ultra control panel
“Two-wire
panel, offering
significant cable
and install cost
savings without
sacrificing
performance”
Eaton’s BiWire Ultra fire detection system, available Features
in 2, 4 and 8 zone, is unlike any other standard
conventional system as the panel, detectors, • Detectors and sounders share the same
sounders and EN54-23 approved beacons all share wiring
the same zone wiring. This delivers significant • One man test facility
savings in both cable and installation costs without • Class change input
sacrificing the systems capability. • Interlink relay functionality for connecting 2
BiWire Ultra panels together
Testing is simple, it only takes one person to review
and ensure the healthy state of the system. Benefits
• Reduced cost of installation
Its modern design and simple interface makes it an
ideal choice for small businesses, primary schools, • Simple system testing by a single fire alarm
retail stores, restaurants and small nursing homes. technician
• Capability to sound class change bell in
EFBW2ZONE EFBW4ZONE EFBW8ZONE schools
No. of zones 2 4 8 • Interlink relay allows for greater system
Detectors per zone 32 32 32 flexibility
Maximum loading 200mA 200mA 200mA • Comprehensive protection for safety of
per zone
building occupants
Repeater Port
Dimensions
Catalogue numbers
Description Code
Compatible devices
Eaton’s BiWire Ultra System can support up to 416 devices* in total. Certified to EN54 parts 2 and 4 it is
designed to meet the recommendations in BS5839.
The new BiWire Ultra system offers innovative devices with the latest technology, including a unique set of
beacons that comply with EN54-23, the latest beacon standard.
*8 Zone panel
• Weatherproof option
Benefits
• Certified for Fire use
• Ideal for high noise environments
• Suitable for open areas, as well as outdoor use
• Easy to maintain and service
Dimensions D
EF5021BWS / EF5021BWSB
Features
D
• Available in both sounder only and sounder VAD
• Certified to EN54-3 & EN54-23
• Standalone base sounder or base sounder VAD offers the
flexibility of use with or without the detector
ERTI
N C F
IO I
C
T
AT
PREVEN
LPCB
ION BO
A
S
R
LO D
Two-wire systems
BiWire Ultra series
5 in 1 Detector
EFBW5IN1DET
Features
• Five modes in one detector
• Offers a range of detector types
• 360° indicator LED using lightpipe technology
• Quick and simple to install
• Easy to maintain/service
Benefits
• Suitable for a broad range of applications
• Wide viewing angle for increased LED visibility
• Positive “lock” indication
• Discreet design for incorporation into any decor Dia
Dimensions
Diameter (mm) Depth (mm) Depth (mm) D1
Description (incl base) (incl base) (excl base) D2
5 in 1 Detector 104 55 42
Catalogue numbers
Description Code
BiWire Ultra base sounder first fix EF5021BWS External Relay 230V BWEXTR230V
BiWire Ultra base sounder VAD first fix EF5021BWSB 2 Zone Option Board BWOB2Z
EFCV8Z
Conventional control panel
Eaton’s 8 zone conventional fire system panel intrinsically safe conventional zone circuits, making
delivers a straightforward, intuituve interface that it suitable for industrial applications.
makes programming and maintenance simple.
Benefits
Approved to EN54-2&4, it offers a comprehensive
• Zones switchable between standard
set of functionalities in a modern, robust
conventional and intrinsically safe zones
and discrete enclosure. It’s appearance and
(using isolator barrier)
performance makes the panel well suited for
life safety notification in a wide variety of small • One man test facility
to medium sized buildings, particularly schools, • Class change input
warehouses, retail stores and office buildings. • Interlink relay functionality for connecting 2
panels together
With the addition of an isolator barrier the panel • Interlink relay allows forgreater system
has the additional flexibility to monitor standard or flexibility
EFCV8ZONE
• Supports an expansion card for Fire Routing
Equipment, Fire Protection Equipment and
No. of zones 8
fire relays per zone
Detectors per zone 32
Maximum loading per zone 32mA
• Modern and discreet enclosure
Repeater Port
No. of sounder circuits 4
Maximum loading per sounder circuit 250mA
Description Code
Eaton 8 Zone Conventional Panel* EFCV8Z-NB
Eaton 8 Zone Conventional Panel EFCV8Z
End of Line Module EOLM-1
8 Zone Relays + FRE/FPE BW0B8Z
12V, 5Ah battery (1pc*) *2 required MB512
FX2200CPD series
Conventional control panel
“A flexible
conventional
solution that
ensures ease
of use and high
reliability"
The FX2200CPD range of conventional control project specific requirements to be easily met, in a
panels provide a solution to any conventional competitive and cost effective package.
system requirement. The advanced features include
a simple “one-shot” user test facility, class change Benefits
contacts, battery voltage alarms and charger
• Compact design
temperature compensation, all included as standard
to ensure ease of use and high reliability. • Surface or semi-flush mounting
• Numerical access code (no lost keys)
Attention to detail is emphasised by the neat log • 2 or 4 zones panels
book holder feature, allowing essential records to • Flexible, high specification system
be stored close to hand, ready for quick reference.
• Simple “one-shot” auto-reset user test facility
For larger installations, custom configuration of
the panels offers even greater flexibility, allowing • Maintenance free poly switch circuit
protection, with auto reset
FX2202 FX2204
No. of zones 2 4
Detectors per zone 32 32
No. of alarm circuits 2 (4 on FX2202CR) 2 (4 on FX2204CR)
Features
• Charger with built in temperature
compensation
• Displays essential information at other key
locations in a large building/site
• Zone fire and fault conditions
• Test mode in operation
• Zones or alarm lines in disabled mode
MUTE SCROLL
Conventional Repeater Panel FXRP2200
H
BUZZER
1 2 3 4 5
Steel Back Box (for use with FX2202/4/8) FX22003300 MB
Fire Alarm System Log Book MFALOG
12V 3.2Ah SLA *1 required MB3A212
D2
FXP5000 series
Conventional control panel
“Contemporary
and compact panel
design that provides
a solution to any
conventional system
NEW
PRODUCT requirement”
FXP50016
No. of zones 16
Detectors per zone 30
No. of alarm circuits 4
Zonal relay card
Dimensions
D1 W2
D2
H1
H2
W1
Catalogue numbers
Description Code
16 zone control panel FXP50016
Fire alarm system log book MFALOG
16 zone panel* EFCV16Z-NB
12V 4Ah SLA battery *2 required MB412
Typical applications:
The remote indicator is ideal for
H
applications such as void spaces
or outside locked or inaccessible
rooms to provide indication of
the activation of an automatic
detector.
W
ERTI
N C F
IO I
C
T
AT
PREVEN
LPCB
ION BO
A
S
R
LO D
Conventional systems
Devices - detectors and remote indicators
Performance
On
D1
D2 On
1 2 3 4
Off
Diameter (mm) Depth (mm) Depth (mm)
Description (incl base) (incl base) (excl base) Description SW1 SW2 SW3 SW4
Multimode detector* 104 42 55 Optical mode - OFF OFF OFF
Optical smoke 104 33 45
Photo-thermal mode - OFF OFF ON
detector
* All other conventional detectors share same dimensions Rate of rise mode - ON OFF OFF
Catalogue numbers
Description Code
H D
Dimensions Features
MBD50R MBD100R
Operating range 5 to 50 metres 50 to 100 metres
Tolerance to beam misalignment Detector ± 0.8˚, Detector ± 0.8˚,
at 35% prism ± 5.0˚ prism ± 5.0˚
D
D Fire alarm thresholds 2.50dB (25%) 2.50dB (25%)
3.74dB (35%) 3.74dB (35%)
6.02dB (50%) 6.02dB (50%)
Optical wavelength 880nm 880nm
Dia
Dia
ERTI
N C F
IO I
C
T
AT
PREVEN
LPCB
ION BO
A
S
R
LO D
Conventional systems
Devices - duct probe detector
Features
Catalogue numbers
Description Code
Callpoints
Two versions of the conventional callpoint are available, the surface or flush
mounted FX201 or the weatherproof FX203. Both have an integral short circuit
isolator and are very simple to install. The callpoints are packaged with 2
frangible glass elements and test key, with a comprehensive range of further
devices available.
Catalogue Numbers
Callpoint shown with protective
hinged cover
Description Code
AT
PREVEN
LPCB
ION BO
A
S
R
LO D
Conventional systems
Devices - bells
Bells
Bells still remain a popular choice for many
applications where they can sometimes be used as
a signal for non-fire purposes, such as class change
in a school.
Typical applications:
Can be used for non-fire
applications, such as class change
in a school. Bells can be used for non fire applications
such as class change in a school
Catalogue numbers
Dia
Description Code
Sounders
We have an extensive range of conventional sounders, designed to meet
every specification’s functional and aesthetic needs. Completely EN54 Pt. 3
certified, each sounder offers a unique solution to your conventional system
requirements.
Sound output
FX003 FX002 FX007 MLC624 FXN824
Sound output 98dB(a) at 1 Metre 105dB(a) max (+/-2) 120dB(a) (+/-2) 100dB(a) at 24V dc 80/90dB(a) (+/-3) @
(+/-2) at 24V dc Max at 1m (tone 5) 1 Metre
114dB(a) (+/-2) Max
at 1m (tone3)
Tones 32 32 32 3 8
Dimensions
D D
D
W
D Dia
H D
Dia
Dia
W
Flush sounder Wall sounder Surface sounder Weatherproof surface Base mountable
sounder sounder
Low current wall sounder 105 105 95 Base mountable sounder 111 26
Catalogue Numbers
Description Code
RoLP LX wall Symphoni LX wall Symphoni LX WP wall These products are all red
FXROLPWR FXSYG1WR (weatherproof) flash, for more options
please contact:
FXSYG1WR-WP
[email protected]
Performance
Solista LX wall Solista LX ceiling RoLP LX wall Symphoni LX wall Symphoni LX
WP wall
Sound output N/A N/A 102dB(A) (Typical tone 100dB(A) (Typical tone 100dB(A) (Typical tone
3 - RoLP) 3 - Symphoni) 3 - Symphoni)
Minimum current consumption 10mA 10mA 22mA 15mA 15mA
EN54-23 coverage reference W-2.4-7.5 C-3-7.5 W-2.4-7.5 W-2.4-7.5 W-2.4-7.5
Coverage volume 135m3 (15m3) 132m3 (21m3) 135m3 (15m3) 135m3 (15m3) 135m3 (15m3)
Flash rate 1Hz (switchable to 1Hz (switchable to 1Hz (switchable to 1Hz (switchable to 1Hz (switchable to
0.5Hz) 0.5Hz) 0.5Hz) 0.5Hz) 0.5Hz)
Dimensions
Dia
Dia D1 Dia
Dia D1 W
W D
H
Dia
Dia
W
SHALLOW BASE SHALLOW BASE
D2 D2
SHALLOW
SHALLOW
SHALLOW
SHALLOW
BASE
D
BASE
D
D2
D2
DEEP
DEEP
D
BASE
BASE
DEEP BASE
DEEP BASE
D D
D
D1
D1
BASE
BASE
WW D
W
W D
H
H
H
W
W
D
D
D
D
H
H
Dia D W H
Description (mm) (mm) (mm) (mm)
Solista LX wall deep base 93 66 - -
Catalogue numbers
Description Code Description Code
cc2478 Fire Systems & VADs Design Guide.qxp_Layout 1 12/02/2014 09:37 Page 1
FXSOLWRS Solista wall red body shallow base 812013FULL-0237X Deep base for Solista LX ceiling FX000WWP
Fire Systems Design Pocket Guide
BS 5839 Part 1:2013 and CoP 0001 for Visual Alarm Devices
Indicators
In areas which do not have to meet the new regulations regarding EN54-23 visual
alarm devices, our range of indicators can still provide reliable light indication.
Catalogue numbers
Description Code
Sounder indicators
In areas which do not have to meet the new regulations regarding EN54-23
visual alarm devices, our range of sounder indicators can still provide excellent
sound quality and light indication.
Dia
Dia
In regions where the EN54‑23 The weatherproof version of the Xenon sounder indicator 93 92
VADs standard is not a sounder indicator is IP65 rated Weatherproof xenon sounder indicator 93 121
requirement, the xenon sounder which allows for installation in
indicator provides an alternative harsher environments.
option to the xenon indicator
- where an audible warning
is required in addition to light
indication.
Holding force 40kg 40kg 45kg 40kg Mains powered heavy duty door retainer MDR240
Power 1.2VA 40mA 1.2VA 40mA 24V dc heavy duty door retainer MDR24L
consumption
Floor mounting bracket for heavy duty door retainers ZMDRFBB
Power supply
Specifically recommended as an auxiliary power
supply unit for fire detection system components
such as electromagnets, notification devices, etc.
Using the unit in large systems eliminates the
problem of long power cable runs which simplifies
installation.
Typical applications:
The new range of EN 54-4 certified safety power supplies offer a
compact, robust and versatile power solution to installers, allowing
them to safely power fire detection and signaling systems in small to
large installations.
Catalogue numbers
Description Code
Typical applications:
The 5900 LX wall alarm device series comprises three versions that are
Features
available with optical, acoustic and optical-acoustic warnings. • Certified to UNI EN54-3 and UNI EN54-23
The optical warning is provided by a highly effective LED flash that • Protection rating IP54
can cover an area of 8.5m x 8.5m at an installation height of 4.2m.
The acoustic warning is provided by a high power internal siren with a • Operating temperature -10°C to +50°C
sound pressure of 85 dB at 1m. • Flash colour – white
The device has a display which shows “FIRE ALARM” backlit by LEDs • Housing – Self-extinguishing white thermos plastic
in the event of an alarm.
Its IP54 protection rating means that the device can be used in both
indoors and outdoors environments, including damp, dusty settings.
Features Dimensions
5945-CSA 5955-CSA 5965-CSA
Optical alarm warning
Acoustic alarm warning
Display lighting - LEDs
Nominal voltage 24V DC
Power consumption @24V 120mA 100mA 130 mA
Contents
Emergency voice communications
Panels
Devices
Outstations 95
VoCALL Network
*Possible to connect up to 4x masters
Our range of EVCS control units cover functionality for all builds, whether small
and basic or larger and more complex. All parts are designed to fully comply with
BS5839 part 9 2011 with EN54-4-A2 compliant power supplies and chargers.
Network master
handset Features
CFVCWM Up to 4 network master handsets per system
Controls up to 152 lines (19 x 8 line exchange units)
Monitored handset
Large high contrast display (4 x 20 character)
Dual network ports
Remote powered handsets, no mains required
Full system event log (fault & configuration)
Dimensions
W D
*Please check with our technical team if dimensions are critical as they may have changed
from time of print
Each system can have up to 4 VoCALL Network 8 line network exchange unit
Master Handsets which gives great flexibility to CFVCX8
larger installations allowing all calls to be monitored
from various control points.
• Wall or desk mount
• Graphical display
• Calls can be made by dialling or selecting the
outstation name
Catalogue numbers
Description Code
VoCALL Compact 5
EFVCC5
Typical applications:
The VoCALL Compact 5 Line Unit is
ideal for smaller installations which
require just a limited number of
outstations and Emergency Assist
Alarms.
The EFVCC5 is a standalone unit
containing the systems master handset,
EN54-4 approved power supply and
connectivity for the 5 outstations.
20mm knockouts are provided for all
system cabling and the housing is of
ample size to support 2x 3.2Ah backup
batteries.
NEW
PRODUCT
Features
Compact 5
Bs5839 pt9 2011 compliant
Monitored handset
Monitored supply and charger
Relay outputs
No programming
Functional with emergency assist alarms
Dimensions
H1 H2 W1 W2 D1 D2 W D
Dimensions (mm) (mm) (mm) (mm) (mm) (mm)
VoCALL Compact 5 surface mounted 280 - 397 - 77 -
VoCALL Compact 5 flush mounted 280 309 397 427 77 16 H
Catalogue numbers
Description Code
Outstations
For disabled refuge systems we offer a number of devices for call functions.
Outstations can offer functionality as a fire telephone or disabled refuge call
point. All outstations are available as a wall mountable unit, or with an optional
bezel to allow the product to be flush mounted.
Dimensions
W2 D1 W2 D1 W D
W1
W1
H1 H2
H1 H2 H
D2
Backbox
Backbox D2
Type A outstation Type B outstation Jack plate
Catalogue numbers
VoCALL Type A outstation, surface mount, red CFVCSHP VoCALL Type B outstation, surface mount, stainless steel CFVCSHFSS
VoCALL Type A outstation, surface mount, stainless steel CFVCSHPSS VoCALL flush mounting bezel for use with any Type B CFVCFHB
outstation, stainless steel
VoCALL Type A outstation, flush mount, red CFVCFHP
VoCALL jack plate CFVCRJP
VoCALL Type A outstation, flush mount stainless CFVCFHPSS
VoCALL roaming handset CFVCRHS
VoCALL Type B outstation, surface mount, red CFVCSHF
Typical applications:
Disabled Toilets.
Includes:
• Power supply unit
• Over door indicator
• Cancel button
• Pull cord unit
• Disabled sticker pack
4 way splitter
Catalogue numbers
Description Code
Stand alone
Emergency assist alarm - stand alone kit CFEAPULLKIT
For use with EVC panel or 4 way splitter
Emergency assist alarm - kit without PSU CFVCEA
Accessories
4 way splitter CFEASL4
PSU for 4 way splitter CFEAPSU
Emergency assist pull cord unit CFEAPULL
Pull cord accessory pack CFEACORD
Disabled sticker (pack of 5) CFEADS
Page
No. Description Cooper Code Menvier Code JSB Code
Addressable
P22 2 Loop Control Panel, Integral Printer, Extended Battery CF30002GPEB DF60002PEB DF60002PEB
P22 4 Loop Control Panel, Integral Printer, Extended Battery CF30004GPEB DF60004PEB DF60004PEB
P24 Optical Smoke Detector (CAP320, MAP820, FXN723) 400002FIRE-0002X 400002FIRE-0008X 400002FIRE-0005X
P26 Australian sounder base (Only for Australian Market) CAS380AU CAS380AU CAS380AU
Page
No. Description Cooper Code Menvier Code JSB Code
P29 VAD wall sounder beacon bell tone CASB393B CASB393B CASB393B
P29 Weatherproof VAD wall sounder beacon bell tone CASB393WPB CASB393WPB CASB393WPB
P34 3 Channel Input/Output Unit Rests on silence alarms CIO351S MIO324S FXN510S
P36 4 Way Mimic Relay Board, 4 Inputs, 4 Outputs CIOP4 CIOP4 CIOP4
P36 8 Way Mimic Relay Board, 8 Inputs, 8 Outputs CIOP8 CIOP8 CIOP8
Product code cross reference
Page
No. Description Cooper Code Menvier Code JSB Code
P37 FC6 Fan controller unit (surface mount) FC6 FC6 FC6
P37 FC18 Fan controller unit (rack mount) FC18 FC18 FC18
P39 MCOM Micro Single Channel Output Unit (recognised as output 400010FIRE-0024X 400010FIRE-0024X 400010FIRE-0024X
unit)
P39 MCOM-S Micro Single Channel Output Unit (recognised as 400012FIRE-0026X 400012FIRE-0026X 400012FIRE-0026X
sounder)
P39 MCOM-R Micro Single Channel Output Unit (5 second reset 400011FIRE-0025X 400011FIRE-0025X 400011FIRE-0025X
pulse)
P39 MCOM--FC Micro Single Channel Output Unit (fan controller) MCOM-FC MCOM-FC MCOM-FC
P39 MCIM Micro Single Channel Input Unit 400008FIRE-0022X 400008FIRE-0022X 400008FIRE-0022X
P39 Mini module box unit (empty box) ULBU ULBU ULBU
P40 Dual-channel LonWorks BMS Interface (non handshake) EC200 EC200 EC200
P40 Single Mode Lon to Fibre Optic Adaptor CFSFL01 CFSFL01 CFSFL01
P40 Dual Channel Lon to Fibre Optic Adaptor CFSFL02 CFSFL02 CFSFL02
P42 Safety Power Supply 24V / 1.5A (batteries not supplied) SPS-2423 SPS-2423 SPS-2423
P42 Safety Power Supply 24V / 2.5A (batteries not supplied) SPS-2433 SPS-2433 SPS-2433
P42 Safety Power Supply 24V / 4.5A (batteries not supplied) SPS-2453 SPS-2453 SPS-2453
P44 Graphical Visualisation Software license 1-2 panels EFGVS1-2 EFGVS1-2 EFGVS1-2
including an EC0232 interface
P44 Graphical Visualisation Software license above 10 panels EFGVS11-PLUS EFGVS11-PLUS EFGVS11-PLUS
including an EC0232 interface
P44 Graphical Visualisation Software license up to 10 panels with EFGVS7-10-TCPIP EFGVS7-10-TCPIP EFGVS7-10-TCPIP
TCP/IP interlink
Product code cross reference
Page
No. Description Cooper Code Menvier Code JSB Code
P44 Graphical Visualisation Software license above 10 panels with EFGVS11-PLUS-TCPIP EFGVS11-PLUS-TCPIP EFGVS11-PLUS-TCPIP
TCP/IP interlink
P44 Graphical Visualisation Designer Software license - no panel EFGVS-DESIGN EFGVS-DESIGN EFGVS-DESIGN
connectivity
P44 Graphical Visualisation Premium Designer Software license EFGVS- EFGVS- EFGVS-
including an EC0232 interface PREMIUMDESGN PREMIUMDESGN PREMIUMDESGN
UL Approved
P49 2 Loop Panel, Integral Printer, Network Card ULCF30002GPNC ULDF60002GPNC ULFX60002GPNC
P49 2 Loop Panel, Integral Printer, Red Metal Box ULCF30002GPRM ULDF60002PRM ULFX60002PRM
P49 2 Loop Panel, Network Card, Red Metal Box ULCF30002GNCRM ULDF60002NCRM ULFX60002NCRM
P49 2 Loop Panel, Integral Printer, Network Card, Red Metal Box ULCF30002GPNCRM ULDF60002PNCRM ULFX60002PNCRM
P49 4 Loop Panel, Integral Printer, Network Card ULCF30004GPNC ULDF60004GPNC ULFX60004GPNC
P49 4 Loop Panel, Integral Printer, Red Metal Box ULCF30004GPRM ULDF60004PRM ULFX60004PRM
P49 4 Loop Panel, Network Card, Red Metal Box ULCF30004GNCRM ULDF60004NCRM ULFX60004NCRM
P49 4 Loop Panel, Integral Printer, Network Card, Red Metal Box ULCF30004GPNCRM ULDF60004PNCRM ULFX60004PNCRM
P49 Rack Mounted 2 Loop Panel c/w Network Card ULR3000L2NC ULR3000L2NC ULR3000L2NC
P49 Rack Mounted 4 Loop Panel c/w Network Card ULR3000L4NC ULR3000L4NC ULR3000L4NC
P50 Optical Smoke Detector (ULCAP320, ULMAP320, ULFX320) 400005FIRE-0011X 400005FIRE-0014X 400005FIRE-0017X
Page
No. Description Cooper Code Menvier Code JSB Code
P55 Exposed Conduit, Surface Mount Back Box (RED) CN109751 CN109751 CN109751
P55 Concealed Conduit Surface Mount Back Box (RED) CN109751 + CN109751 + CN109751 +
CN104486 CN104486 CN104486
P56 Conventional Single Action Pull Station (back box ordered SG42BK2 SG42BK2 SG42BK2
seperately)
P56 Conventional Double Action Pull Station (back box ordered SG42BK1 SG42BK1 SG42BK1
seperately)
P56 Back box for conventional, surface mounting SGB32S SGB32S SGB32S
P58 3 Channel Input/Output Unit Resets on silence alarms ULCIO351S ULCIO351S ULCIO351S
P58 ULMCOM Micro Single Channel Output Unit (recognised as 400015FIRE-0029X 400015FIRE-0029X 400015FIRE-0029X
output unit)
P58 ULMCOM-S Micro Single Channel Output Unit (recognised as 400016FIRE-0030X 400016FIRE-0030X 400016FIRE-0030X
sounder)
P58 ULMCIM Micro Single Channel Input Unit (recognised as input 400013FIRE-0027X 400013FIRE-0027X 400013FIRE-0027X
unit)
P58 ULMCIM-C Micro Single Channel Input Unit (recognised as 400014FIRE-0028X 400014FIRE-0028X 400014FIRE-0028X
callpoint)
P58 Mini Module Box Unit (Empty box) ULBU ULBU ULBU
Conventional
Page
No. Description Cooper Code Menvier Code JSB Code
P67 BiWire Ultra wall sounder VAD, weatherproof EF009SBWP EF009SBWP EF009SBWP
P67 BiWire Ultra base sounder first fix EF5021BWS EF5021BWS EF5021BWS
P67 BiWire Ultra base sounder VAD first fix EF5021BWSB EF5021BWSB EF5021BWSB
P67 BiWire Ultra Slim Base sounder with cover EF5023S EF5023S EF5023S
P71 Steel back box (for use with FX2202/4/8) FX22003300 MB FX22003300 MB FX22003300 MB
Page
No. Description Cooper Code Menvier Code JSB Code
P78
CXPC
MBG917
CXPC
FX203
CXPC
P78
MBGBEZ
MBGSP
MBGBEZ
MBGSP
MBGBEZ
P78
P78
P78
safety solutions
Resettable Element Kit (pack of 10)
FX5G
MBG119
MBGREKIT
FX5G
MBG119
MBGREKIT
FX5G
MBG119
P80 MFSSBB Back Box For FX003, Red 591001FULL-0016 591001FULL-0016 MFSSBB
P80 FX002SB Low Profile Surface Sounder, Red FX002SB FX002SB FX002SB
P80 MDS824COV Blanking Plate for MDS824 (pack of 5) 590037FULL-0305 590037FULL-0305 MDS824COV
P82 FXSOLWRS Solista Wall Red Body Shallow Base 812013FULL-0237X 812013FULL-0237X FXSOLWRS
P82 FXSOLWRD Solista Wall Red Body Deep Base 812005FULL-0107X 812005FULL-0107X FXSOLWRD
P82 FXROLPWR RoLP Wall Red Body Base & Sounder 8500025FULL-0025X 8500025FULL-0025X FXROLPWR
P82 FXROLPWR-B RoLP Wall Red Body Base 8500040FULL-0219X 8500040FULL-0219X FXROLPWR-B
P82 FXSYR-B Symphoni LX Wall Base Red Body 8500095FULL-0231X 8500095FULL-0231X FXSYR-B
P82 FXSYG1WR-WP Symphoni LX Wall Weatherproof Red Body 8500050FULL-0249X 8500050FULL-0249X FXSYG1WR-WP
P82 FXSYR-B-WP Symphoni LX Wall Weatherproof Base Red Body 8500100FULL-0247X 8500100FULL-0247X FXSYR-B-WP
Page
No. Description Cooper Code Menvier Code JSB Code
P84 FL-RL-R-D Weatherproof IP65 xenon sounder indicator 640031FULL-0111X 640031FULL-0111X FL-RL-R-D
P86 Mains Powered Heavy Duty Door Retainer MDR240 MDR240 MDR240
P86 Floor Mounting Bracket for Heavy Duty Door Retainers ZMDRFBB ZMDRFBB ZMDRFBB
P86 Floor Mounting Bracket for Compact Door Retainers FX021LCFB FX021LCFB FX021LCFB
P86 Spare Striker Plate For Either Magnet ZMDRSWIV ZMDRSWIV ZMDRSWIV
P87 Safety Power Supply 24V / 1.5A (batteries not supplied) SPS-2423 SPS-2423 SPS-2423
P87 Safety Power Supply 24V / 2.5A (batteries not supplied) SPS-2433 SPS-2433 SPS-2433
P87 Safety Power Supply 24V / 4.5A (batteries not supplied) SPS-2453 SPS-2453 SPS-2453
P91 VoCALL 10 Line Networkable Master System Handset CFVCWM CFVCWM CFVCWM
P93 VoCall Compact 5 Line Master Exchange Unit, Graphite EFVCC5 EFVCC5 EFVCC5
P93 VoCall Compact 5 Line Master Exchange Unit, Stainless Steel EFVCC5-FB EFVCC5-FB EFVCC5-FB
P95 VoCall Type A Outstation, Surface Mount, Red CFVCSHP CFVCSHP CFVCSHP
P95 VoCall Type A Outstation, Surface Mount, Stainless Steel CFVCSHPSS CFVCSHPSS CFVCSHPSS
P95 VoCall Type A Outstation, Flush Mount, Red CFVCFHP CFVCFHP CFVCFHP
P95 VoCall Type A Outstation, Flush Mount, Stainless Steel CFVCFHPSS CFVCFHPSS CFVCFHPSS
P95 VoCall Type B Outstation, Surface Mount, Red CFVCSHF CFVCSHF CFVCSHF
P95 VoCall Type B Outstation, Surface Mount, Green CFVCSHFG CFVCSHFG CFVCSHFG
P95 VoCall Type B Outstation, Surface Mount, Stainless Steel CFVCSHFSS CFVCSHFSS CFVCSHFSS
P95 VoCall Flush Mounting Bezel Type B Outstation, Stainless Steel CFVCFHB CFVCFHB CFVCFHB
P98 Emergency assist alarm - stand alone kit CFEAPULLKIT CFEAPULLKIT CFEAPULLKIT
P98 Emergency assist alarm - kit without PSU CFVCEA CFVCEA CFVCEA
Contact
110 EATON
EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018
EATON - FIRE
- FIRE AND
AND VOICE
VOICE ALARM
ALARM SYSTEMS
SYSTEMS CF-CC2556
2014 January
CF-CC2556 June 2018
2014 110
Notes
EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 April 2018 111
At Eaton, we’re energized by the challenge of powering a world
that demands more. With over 100 years experience in electrical
power management, we have the expertise to see beyond today.
From groundbreaking products to turnkey design and engineering
services, critical industries around the globe count on Eaton.
We power businesses with reliable, efficient and safe electrical
power management solutions. Combined with our personal
service, support and bold thinking, we are answering tomorrow’s
needs today.
Follow the charge with Eaton, visit eaton.eu
Eaton
Electrical Sector EMEA
Route de la Longeraie 7
1110 Morges, Switzerland
Eaton
Eaton Electrical Systems Ltd.
Wheatley Hall Road
Doncaster
South Yorkshire
DN2 4NB
United Kingdom
Tel: +44 (0)1302 303 999
Fax: +44 (0)1302 303 333
Email: [email protected]
Web: w ww.cooperfire.com
www.uk.eaton.com
© 2018 Eaton
All Rights Reserved
Pub Reference: CF-CC2556 / CSSC-910
April 2018