17.887 KN 11.512 KN Calculation of Wind Load For Side Wall Cladding

The document calculates wind loads on various parts of a structure based on wind speed, coefficients, dimensions, and surface areas. It determines: 1) A design wind speed of 60 m/s based on basic wind speed and terrain coefficients. 2) Wind pressures of 3.11 KN/m2 for windward and 2.002 KN/m2 for leeward sides of the roof. 3) Resulting wind forces of 17.887 KN for windward roof and 11.512 KN for leeward roof.

Uploaded by

Antony Jeyendran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
367 views4 pages

17.887 KN 11.512 KN Calculation of Wind Load For Side Wall Cladding

The document calculates wind loads on various parts of a structure based on wind speed, coefficients, dimensions, and surface areas. It determines: 1) A design wind speed of 60 m/s based on basic wind speed and terrain coefficients. 2) Wind pressures of 3.11 KN/m2 for windward and 2.002 KN/m2 for leeward sides of the roof. 3) Resulting wind forces of 17.887 KN for windward roof and 11.512 KN for leeward roof.

Uploaded by

Antony Jeyendran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

CALCULATION OF WIND LOAD

Length of one purlin 5.750 m


Spacing of purlins 1.000 m
Basic wind speed 55 m/s
Coefficient K1 1
Coefficient K2 1.09
Coefficient K3 1 (Plain terrain)

Coefficient K4(Cyclonic) 1

Vz=K1*K2*K3*V 60 m/s (Plain terrain)

Design wind speed 60 m/s

Wind pressure=(0.6*Vz*Vz) 2.16 KN/m2


Height of structure till eave level-H 13.0 m 1L
Width of structure-W 30 m 0.0333333 L/W
H/W 0.4333333333

Internal Pressure Coefficients


Cpi1 0.5
Cpi2 -0.5

External Pressure Coefficients


Roof angle 5.71
H/W 0.4333333333
Wind angle 0
EF 0.9426
GH 0.4
Wind angle 90
EG 0.8
FH -0.4284

Cpe+Cpi(Windward) 1.4426
Cpe+Cpi(Leeward) 0.9284

Wind Pressure-Windward 3.11 KN/m2


Wind Pressure-Leeward 2.002 KN/m2
Surface Area 5.750 m2

Wind Force-Windward 17.887 KN


Wind Force-Leeward 11.512 KN

Calculation of Wind load for Side wall cladding


Internal Pressure Coefficients
Cpi1 0.5
Cpi2 -0.5

External Pressure Coefficients


Roof angle 5.71
H/W 0.4333333333
Wind angle 0
A -0.7
B -0.20
Wind angle 90
A -0.5
B -0.5

Cpe+Cpi(Windward) 1.2
Cpe+Cpi(Leeward) 1

Wind Pressure-Windward 2.59 KN/m2


Wind Pressure-Leeward 2.156 KN/m2
Surface Area 5.750 m2

Wind Force-Windward 14.879 KN


Wind Force-Leeward 12.399 KN

Calculation of Wind load for Front wall cladding


Internal Pressure Coefficients
Cpi1 0.5
Cpi2 -0.5

External Pressure Coefficients


Roof angle 5.71
H/W 0.4333333333
Wind angle 0
C -0.6
D -0.60
Wind angle 90
C 0.7
D -0.1

Cpe+Cpi(Windward) 1.2
Cpe+Cpi(Leeward) 1.1

Wind Pressure-Windward 2.59 KN/m2


Wind Pressure-Leeward 2.372 KN/m2
Surface Area 5.750 m2
Wind Force-Windward 14.879 KN
Wind Force-Leeward 13.639 KN