This document is a lab manual submitted by Muhammad Noman Saleem, student number 2015-EE-36 (A), to Sir Habib Wajid of the Department of Electrical Engineering at the University of Engineering and Technology in Lahore. The lab manual contains 14 experiments on studying the characteristics and coordination of various types of power system protection relays, including overcurrent, directional overcurrent, over/under voltage, frequency, and reverse power relays. It also covers experiments on ground fault protection, protection of motors and transformers, and coordination of relays in transmission lines.
Download as DOCX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
189 views
Power System Protection Lab
This document is a lab manual submitted by Muhammad Noman Saleem, student number 2015-EE-36 (A), to Sir Habib Wajid of the Department of Electrical Engineering at the University of Engineering and Technology in Lahore. The lab manual contains 14 experiments on studying the characteristics and coordination of various types of power system protection relays, including overcurrent, directional overcurrent, over/under voltage, frequency, and reverse power relays. It also covers experiments on ground fault protection, protection of motors and transformers, and coordination of relays in transmission lines.
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3
Power System Protection Lab
Lab Manuals
Submitted To : Sir Habib Wajid Submitted by : Muhammad Noman Saleem 2015-EE-36 (A)
Department of Electrical Engineering
University of Enginnering and Technology, Lahore Table of Contents
Experiment#1 Study of characteristics of DMT and IDMT type Overcurrent relay
Experiment#2 Study of characteristics of DMT and IDMT type Directional Overcurrent relay Experiment#3 Study of characteristics of DMT and IDMT type Over/Under voltage relay Experiment#4 Study of characteristics of DMT and IDMT type Frequency relay Experiment#5 Study of characteristics of DMT and IDMT type Reverse Power relay Experiment#6(a) Study of performance of Power System with Grounded-Neutral & Ungrounded- Neutral during Ground Faults Experiment#6(a) Study of performance of Ground Fault Neutralizer during Ground Faults Experiment#7 Study of Steady state performance of CT and VT Experiment#8 Coordination of DMT and IDMT type Overcurrent relay Experiment#9 Coordination of DMT and IDMT type Overcurrent and Directional Overcurrent Relays in Parallel Transmission Lines Experiment#10 Neutral Grounding of Synchronous Generator through Grounding Transformer Experiment#11 Protection of Induction-Motor by using Numeric Relay SEL-710 Experiment#12 Reverse Power Protection and Sequential Tripping of a grid connected Generator Experiment#13 Differential Protection for Power Transformer Experiment#14 Ground Fault Detection in an Ungrounded-System