1-5/8" CELLFLEX Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PRODUCT DATASHEET

LCF158-50CPR

1-5/8" CELLFLEX® Premium Attenuation Low-Loss Foam-Dielectric


Coaxial Cable
CELLFLEX®1-5/8" premium attenuation low loss flexible cable

FEATURES / BENEFITS
Ultra Low Attenuation
The further reduced attenuation of CELLFLEX® premium attenuation coaxial cable results in extremly
efficient signal transfer in your RF system, especially at high frequencies.
Complete Shielding
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
Low VSWR 1-5/8" CELLFLEX® Low-Loss Foam
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise. Dielectric Coaxial Cable
Outstanding Intermodulation Performance
CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless
cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.

Technical Features

APPLICATIONS
Applications Main feed line, Riser-rated In-Building, CPR classified cable
STRUCTURE
Cable Type Foam-Dielectric, Corrugated
Size 1-5/8"
Jacket Option Black
Inner Conductor mm (in) 17.6 (0.69) Corrugated Copper Tube
Dielectric mm (in) 42.4 (1.67) Foam Polyethylene
Outer Conductor mm (in) 46.4 (1.83) Corrugated Copper
Jacket mm (in) 50.2 (1.98) Polyethylene, PE, Metalhydroxite Filling
ELECTRICAL SPECIFICATIONS
Impedance ȍ 50 +/- 1
Maximum Frequency GHz 2.75
Velocity % 90.0
Capacitance pF/m (pF/ft) 74 (22.5)
Inductance µH/m (µH/ft) 0.185 (0.056)
Peak Power Rating kW 310.0
RF Peak Voltage Volts 5600.0
Jacket Spark Volt RMS 10000.0
Inner Conductor dc Resistance ȍm ȍft) 1.3 (0.4)
Outer Conductor dc Resistance ȍm ȍft) 0.47 (0.14)
Premium for 380-410, 694-960, 1695-2200, 2400-2496 MHz
Return Loss (VSWR) Performance
Standard for 500-694, 1452-1496, 2300-2400, 2496-2700 MHz
Maximum Return Loss dB (VSWR) Premium: 24 (1.135) and Standard: 20 (1.222)
Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request.
Temperature & Power Standard
MECHANICAL SPECIFICATIONS
Cable Weight, Nominal kg/m (lb/ft) 1.25 (0.84)
Minimum Bending Radius, Single Bend mm (in) 200 (8)
Minimum Bending Radius, Repeated Bends mm (in) 500 (20)
Bending Moment Nm (lb*ft) 42
Tensile Strength N (lb) 2500 (562)
Recommended / Maximum Clamp Spacing m (ft) 1.2 / 1.5 (4 / 5)

LCF158-50CPR REV: B REV DATE: 23.July.2019 www.rfsworld.com

All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 1 of 2
PRODUCT DATASHEET
LCF158-50CPR

1-5/8" CELLFLEX® Premium Attenuation Low-Loss Foam-Dielectric


Coaxial Cable
ATTENUATION AND POWER RATING
Frequency Attenuation Power TESTING AND ENVIRONMENTAL
MHz dB/100m dB/100ft kW Fire Performance Flame Retardant, LS0H
0.5 0.04 0.013 258.00 Flame Retardant Jacket Specifications Meets/Exceeds: IEC 60754-1, -2; IEC 60332-1, -3.C; UL 1581;
1 0.06 0.019 182.00 UL 1666; NEC type CATVR; CPR:
1.5 0.08 0.023 148.00 https://products.rfsworld.com/userfiles/cpr/rfs-products-cpr-
compliance.pdf
2 0.09 0.027 128.00
Installation Temperature -15 to 60 (5 to 140) °C(°F)
10 0.20 0.06 56.90
Storage Temperature -70 to 85 (-94 to 185) °C(°F)
20 0.28 0.086 39.90
30 0.34 0.105 32.50 Operation Temperature -50 to 85 (-58 to 185) °C(°F)
50 0.45 0.137 25.00
88 0.60 0.184 18.60
100 0.64 0.196 17.40
108 0.67 0.205 16.70
150 0.80 0.243 14.00
174 0.86 0.263 13.00
200 0.93 0.283 12.10
300 1.16 0.352 9.66
400 1.35 0.412 8.30
450 1.44 0.439 7.78
500 1.53 0.465 7.33
512 1.55 0.471 7.23
600 1.69 0.515 6.63
700 1.84 0.561 6.09
750 1.91 0.583 5.87
800 1.98 0.604 5.66
824 2.02 0.615 5.55
894 2.11 0.644 5.31
900 2.12 0.646 5.29
925 2.15 0.656 5.21
960 2.20 0.67 5.10
1000 2.25 0.686 4.98
1250 2.56 0.779 4.38
1400 2.73 0.832 4.11
1500 2.84 0.866 3.95
1700 3.06 0.932 3.66
1800 3.16 0.963 3.55
2000 3.36 1.03 3.34
2100 3.46 1.06 3.24
2200 3.56 1.08 3.15
2400 3.75 1.14 2.99
2500 3.84 1.17 2.92
2600 3.93 1.20 2.85
2700 4.02 1.23 2.79
2750 4.07 1.24 2.75

Attenuation at 20°C (68°F) cable temperature;


tolerance +/- 5% max.; Mean power rating at
40°C (104°F) ambient temperature

External Document Links Notes

LCF158-50CPR REV: B REV DATE: 23.July.2019 www.rfsworld.com

All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 2 of 2

You might also like