MID 039 - CID 1595 - FMI 05: Troubleshooting
MID 039 - CID 1595 - FMI 05: Troubleshooting
MID 039 - CID 1595 - FMI 05: Troubleshooting
Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758238
Illustration 1 g02026953
This diagnostic code is associated with the "Attachment Valve #3 Extend Pressure" Solenoid. The
FMI 05 diagnostic code means that the Machine ECM has determined that the current is below
normal.
• The energizer circuit of the solenoid for the modulating valve is open.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1595 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
K858-YL) to contact 2 (wire K869-BU).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous test remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-42 (wire K858
-YL) to contact J2-21 (wire K869-BU).
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test
Step 3.
• NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire K858-YL or in wire K869-BU of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1595 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The Machine ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1595 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:44:37 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758305
Illustration 1 g02026953
This diagnostic code is associated with the "Attachment Valve #3 Extend Pressure" Solenoid. The
FMI 06 diagnostic code means that the Machine ECM has determined that the current of the solenoid
is above normal.
• The energizer circuit of the solenoid for the modulating valve is shorted to ground.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1595 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 1595 FMI 06 diagnostic code changes to a CID 1595 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 1595 FMI 06 diagnostic code changes to a CID 1595 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 1595 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-42 (wire
K858-YL) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-42 (wire K858-YL) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1595 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1595 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:44:51 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434667
Illustration 1 g02027013
This diagnostic code is associated with the "Attachment Valve #1 Retract Pressure" Solenoid. The
FMI 03 diagnostic code means that the Machine ECM has determined that the voltage is above
normal.
For machines equipped with the E-Fence feature, reference Troubleshooting, " E-Ceiling and
Cab Avoidance - Troubleshoot"
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
• The solenoid energize circuit for the "Attachment Valve #1 Retract Pressure" is shorted to the
+battery circuit.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1596 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE
+BATTERY CIRCUIT
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-32
(wire K860-BU) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-32 (K860-BU) and the circuit that has a low
resistance measurement.
STOP
A. Inspect the contacts and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Expected Result:
Results:
• YES - The CID 1596 FMI 03 diagnostic code is active. The problem has not been corrected.
The Machine ECM may have failed.
Repair: A failure of the Machine ECM is unlikely. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1596 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the disconnected and reconnected harness connectors. Resume normal machine
operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:45:06 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434677
Illustration 1 g02027013
This diagnostic code is associated with the "Attachment Valve #1 Retract Pressure" Solenoid. The
FMI 05 diagnostic code means that the Machine ECM has determined that the current is below
normal.
For machines equipped with the E-Fence feature, reference Troubleshooting, " E-Ceiling and
Cab Avoidance - Troubleshoot"
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
• The solenoid energize circuit for the "Attachment Valve #1 Retract Pressure" solenoid is open.
• The return circuit of the "Attachment Valve #1 Retract Pressure" solenoid is open.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1596 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
K860-BU) to contact 2 (wire K868-BR).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" to verify
the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous test remains in place.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
D. At the machine harness connector, measure the resistance from signal contact J2-32 (wire K860
-BU) to contact J2-19 (wire K868-BR).
Expected Result:
Results:
• OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test
Step 3.
• NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire K860-BU or in wire K868-BR of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1596 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: A failure of the Machine ECM is unlikely. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1596 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The diagnostic code was probably caused by a poor electrical connection that was
resolved when a harness connector was disconnected and reconnected. Resume normal machine
operation.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:45:26 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434686
Illustration 1 g02027013
This diagnostic code is associated with the "Attachment Valve #1 Retract Pressure" Solenoid. The
FMI 06 diagnostic code means that the Machine ECM has determined that the current of the solenoid
is above normal.
For machines equipped with the E-Fence feature, reference Troubleshooting, " E-Ceiling and
Cab Avoidance - Troubleshoot"
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
• The solenoid energize circuit for the "Attachment Valve #1 Retract Pressure" solenoid is
shorted to ground.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1596 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 1596 FMI 06 diagnostic code changes to a CID 1596 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 1596 FMI 06 diagnostic code changes to a CID 1596 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 1596 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
A. Turn the key start switch and the disconnect switch to the OFF position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
D. At the machine harness connector, measure the resistance from the signal contact J2-32 (wire
K860-BU) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-32 (wire K860-BU) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1596 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The Machine ECM may have failed.
Repair: Is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1596 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Repair: The diagnostic code was probably caused by a poor electrical connection that was
resolved when a harness connector was disconnected and reconnected. Resume normal machine
operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:45:40 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i02413102
Illustration 1 g01207600
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Illustration 2 g01207601
Machine ECM
(Located in the Compartment to the Rear of the Cab on the left side of the machine)
(1) Controller
(2) J1 Connector
(3) J2 Connector
The electronic controls can communicate with each other through the Cat Data Link. Information
from these electronic controls can be accessed through the machine monitor or by using the
Caterpillar Electronic Technician (Cat ET) on a laptop computer.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Illustration 3 g01207656
(located behind the operator's seat, under the Right Side Switch Console)
The service connector for the Cat ET is located in the operators compartment. The connector is
located behind the seat on the right side of the cab.
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:16:53 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 6
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03928549
Diagnostic Capabilities
SMCS - 1400
Monitoring System
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 6
Illustration 1 g01143406
(1) Up key
(8) OK key
The ECM uses the main display module on the Monitoring System for showing diagnostic
information to service personnel. Diagnostic information concerning the ECM is sent on the Cat Data
Link to the Monitoring System. Service personnel must be familiar with the Monitoring System in
order to troubleshoot the ECM.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 6
Illustration 2 g02153474
"Service" screen
For troubleshooting the ECM, access the "Service" screen of the Monitoring System. Select the
"Diagnostic" option. See Illustration 2.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 6
Illustration 3 g00777826
The Caterpillar Electronic Technician (ET) is a software program that is used to access data. The
service technician can use the Caterpillar Electronic Technician in order to perform maintenance
work on the machine. Some of the options that are available with the Caterpillar Electronic
Technician are listed:
• View Diagnostic codes. See Troubleshooting, "Using the Caterpillar Electronic Technician to
Determine Diagnostic Codes".
• Program the ECM (Flash). This is done with the "WINflash" program. See Testing and
Adjusting, "Electronic Control Module (ECM) - Flash Program".
• Print reports.
The following list contains some of the diagnostic functions and programming functions that are
performed by the service tools.
• The status of most of the inputs and the outputs are displayed.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 6
• Display the status of the input and output parameters in real time.
• The number of occurrences and the clock hour of the first occurrence and the last occurrence is
displayed for each logged diagnostic code.
• The definition for each logged diagnostic code and each event is displayed.
See Troubleshooting, "Diagnostic Code List" for the list of diagnostic codes for the ECM.
See Troubleshooting, "Using the Caterpillar Electronic Technician to Determine Diagnostic Codes".
Diagnostic information is accessed with the following drop-down menus:
Illustration 4 g00867289
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 6
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:20:00 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 7
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i02796794
The following table lists the diagnostic codes for the Machine Control (MID 039). When a diagnostic
code becomes active, refer to the Troubleshooting section of this manual for a specific
troubleshooting procedure.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 7
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 7
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 7
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 7
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 7
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 7 of 7
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:20:47 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 7
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03928529
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 7
Illustration 1 g01143406
(1) Up key
(8) OK key
The "DIAGNOSTIC" menu option is entered by selecting "DIAGNOSTIC" from the "SERVICE"
menu. Press the up key (1) or down key (6) until "DIAGNOSTIC" is highlighted in order to select
this option. Then press the "OK" key (8). Refer to Illustration 1.
Note: Refer to Systems Operation, RENR8068, "Service Mode" for instructions to get to the
"SERVICE" menu.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 7
Illustration 2 g02153474
When "DIAGNOSTIC" is selected, the diagnostic information can be checked. The "DIAGNOSTIC"
menu has the following options:
• ACTIVE ERROR
• LOGGED ERROR
• LOGGED EVENT
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 7
Illustration 3 g02153478
The "ACTIVE ERROR" menu displays active errors in the MID: CID - FMI format. Press the up key
(1) or down key (6) in order to scroll through the active errors.
The "LOGGED ERROR" menu displays logged errors in the MID: CID - FMI format. Press the up
key (1) or down key (6) in order to highlight the desired item. Press the "OK" key (8) in order to see
the detail of the logged error. The detail of a logged error will display the following items:
Illustration 4 g02153480
When the detailed view of the "LOGGED ERROR" view is displayed as in Illustration 4, the logged
errors can be deleted. Press the "OK" key (8) in order to delete the logged error. The delete
confirmation screen will appear. To confirm the delete request move the cursor to the "YES" option
and press the "OK" key (8). Refer to Illustration 5.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 7
Illustration 5 g02153482
The "LOGGED EVENT" menu displays logged events in the MID: EID - LEVEL format. Press the
up key (1) or down key (6) in order to highlight the desired item. Press the "OK" key (8) in order to
see the detail of the logged event. The detail of a logged event will display the following items:
EID - Event ID
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 7
Illustration 6 g02153485
When the detailed view of the "LOGGED EVENT" menu is displayed as in Illustration 6, the logged
events can be deleted. Press the "OK" key (8) in order to delete the logged error. The delete
confirmation screen will appear. To confirm the delete request move the cursor to the "YES" option
and press the "OK" key (8). Refer to Illustration 7
Illustration 7 g02153487
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 7 of 7
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:21:12 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04000853
Connect the Caterpillar ET to the machine. Turn the key switch to the RUN position. Start the Cat
ET. The Cat ET will initiate communications with the Electronic Control Modules on the machine.
After communication has been established, the Cat ET will list the Electronic Control Modules.
Choose the desired Electronic Control Module. After the diagnostic codes have been determined with
the Cat ET, see the test procedure for the corresponding diagnostic code.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Illustration 1 g00859671
The following procedures may cause new diagnostic codes to be logged. Therefore, before any
procedures that are performed, make a list of all the active diagnostic codes in order to determine the
system problems. Clear the diagnostic codes that were caused by the procedure, when each procedure
is complete.
Note: Before performing a procedure, always check all the circuit breakers. Repair the cause of any
circuit breaker that is tripped.
A screen is provided in Cat ET for active diagnostic codes. The screen will display the diagnostic
codes that are active. Active diagnostic information shall include a component identifier (CID), a
failure mode identifier (FMI) and a text description of the problem.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Illustration 2 g00859762
A screen is provided in Cat ET for logged diagnostic codes. The screen will display diagnostic codes
that are logged. The Cat ET will log diagnostic codes that are intermittent. The logged diagnostic data
shall include a component identifier (CID), a failure mode identifier (FMI), and a text description of
the problem. Also, the logged diagnostic data shall include the number of occurrences of the problem
and two time stamps. The time stamp displays the first occurrence of the problem and the time stamp
displays the most recent occurrence of the problem.
Diagnostics are logged in non-volatile memory. On powerup, the ECM will clear any diagnostic
codes that have not been detected or active within the last 150 hours of machine operation.
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:21:28 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04161812
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Illustration 1 g02364556
This diagnostic code is associated with the 8VDC Sensor Supply circuit. An FMI 06 diagnostic code
means the ECM has determined the current of the sensor supply circuit is above normal.
Poor connections are often the cause of a problem in electrical circuits. Before performing this
procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 0041 FMI 06 is
still active, before performing this procedure.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
A. Turn the disconnect switch and the key start switch to the ON position.
B. Do not disconnect any of the machine harnesses at this time. Check for +8 VDC at the harness
connector of every sensor supplied by the ECM +8 VDC power supply.
Note: An 8VDC Sensor Supply ground return is also found at contact J1-14 (235-BK).
Always check these parallel ground wires. Make sure to repair or replace any that are
found open.
Expected Result:
Results:
• YES - The voltages are 8.0 ± 0.5 DCV. Check if the diagnostic code is still active. If the code is
still active, go to Test Step 2.
• NO - The voltage at one or more of the sensors is not 8.0 ± 0.5 DCV. There is a problem with
the ECM +8 VDC voltage supply.
Repair: Refer to the complete electrical schematics for the machine. Investigate and repair the
+8 VDC power supply problem.
After +8 DCV power supply problem is repaired, check if the 0041 FMI 06 diagnostic code is
still active. If the diagnostic code is still active, go to Test Step 2.
A. The disconnect switch and the key start switch remain in the ON position.
B. One at a time, disconnect and reconnect each and every sensor supplied by this ECM 8 VDC
Sensor Supply.
C. While each sensor is disconnected, check the status of the CID 0041 FMI 06 diagnostic code.
Expected Result:
The CID 0041 FMI 06 diagnostic code remains active while each sensor is disconnected and
reconnected.
Results:
• YES - None of the disconnected sensors causes the diagnostic code to change. None of the
sensors are causing the problem. Go to Test Step 4.
• NO - While one sensor is disconnected, the CID 0041 FMI 06 diagnostic code becomes
inactive. That sensor is causing the problem.
Go to Test Step 4.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect both the J1 and J2 harness connectors from the machine ECM.
C. At the J1 machine harness connector for the ECM, measure the resistance from connector
contact J1-27 (E472-GN), the ECM 8 VDC Sensor Supply, to all possible sources of ground in
both the J1 and J2 ECM harness connectors.
Expected Result:
Results:
• NO - A resistance is not more than 5000 ohms. The 8 VDC Sensor Supply output is shorted to
ground.
Go to Test Step 4.
A. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are securely fastened.
B. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0041 FMI 06 diagnostic code is no longer active. The code does not exist at
this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
• NO - The CID 0041 FMI 06 diagnostic code is still active. The problem has not been corrected.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 4 again. If the
problem has NOT been found, and the original code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:21:52 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04140751
Illustration 1 g02025054
This diagnostic code is associated with the Fuel Level sensor. An FMI 04 diagnostic code means the
machine ECM has determined the sensor circuit voltage is below normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all the machine harnesses and connectors involved in the circuit. Make
sure to verify that all of the connections in the circuit are clean, secure, and in good condition.
Correct any problems found with any of the connections. Verify the diagnostic code CID 0096
FMI 04 is still active, before continuing with this procedure.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those diagnostic codes when the original diagnostic code has been corrected.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the machine harness connector from the Fuel Level sensor.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The diagnostic code remains active. The sensor is correct. Go to Test Step 2.
Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. The Fuel Level sensor remains disconnect from the harness connector.
D. At the machine harness connector for the Monitor, measure the resistance from the contact for
wire 495-GNof the Monitor harness connector to all possible sources of ground. Measure the
resistance to all other contacts used in the Monitor harness connector.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
• YES - The measurements all are more than 5000 ohms. The harness is correct. Go to Test Step
3.
• NO - A resistance measurement is not more than 5000 ohms. There is a short in the machine
harness.
Repair: The short is between wire 495-GN and the wire with the low resistance. Repair or
replace the machine harness.
Go to Test Step 3.
A. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips on each connector are securely fastened.
B. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0096 FMI 04 diagnostic code is not active and does not exist at this time.
Repair: The cause for that problem has been repaired. Return the machine to normal operation.
STOP
• NO - The CID 0096 FMI 04 code is still active. The cause for the code has not been repaired.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are securely fastened. From Test Step 1, perform this
procedure again. If the cause for this problem was not found this time, and the original
diagnostic code is still active, the ECM may have failed.Prior to replacing an ECM, always
contact your Dealership Technical Communicator for possible consultation with Caterpillar, or
with the Dealer Solutions Network. This consultation may greatly reduce repair time. If the
ECM needs to be replaced, see Testing and Adjusting, "Electronic Control Module (ECM) -
Replace".
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:23:44 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04140752
Illustration 1 g02025054
This diagnostic code is associated with the Fuel Level sensor. An FMI 05 diagnostic code means the
machine ECM has determined the sensor circuit current is below normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all the machine harnesses and connectors involved in the circuit. Make
sure to verify that all of the connections in the circuit are clean, secure, and in good condition.
Correct any problems found with any of the connections. Verify the diagnostic code CID 0096
FMI 05 is still active, before continuing with this procedure.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those diagnostic codes when the original diagnostic code has been corrected.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the machine harness connector from the Fuel Level sensor.
C. At the Fuel Level sensor machine harness connector, place a jumper wire between the contact
for wire 495-GN to the contact for wire 235-BK in the sensor harness connector.
D. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The diagnostic code remains active. The sensor is not the problem. Go to Test Step 2.
Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connecting the Fuel Level sensor to the Monitor module.
D. At the harness connector for the Monitor, measure the resistance from signal contact 1 (wire
495-GN) to 1 (wire 235-BK) in the Monitor harness connector.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Results:
• YES - The resistance is less than 5.0 ohms. The harness is correct. Go to Test Step 3.
• NO - A resistance is more than 5.0 ohms. There is an open circuit in the machine harness.
Repair: The open is in wire 495-GN or in wire 235-BK of the machine harness. Repair or
replace the machine harness.
Go to Test Step 3.
A. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips on each connector are securely fastened.
B. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0096 FMI 05 diagnostic code is not active and does not exist at this time.
Repair: The cause for that problem has been repaired. Return the machine to normal operation.
STOP
• NO - The CID 0096 FMI 05 code is still active. The cause for the code has not been repaired.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are securely fastened. From Test Step 1, perform this
procedure again. If the cause for this problem was not found this time, and the original
diagnostic code is still active, the ECM may have failed.Prior to replacing an ECM, always
contact your Dealership Technical Communicator for possible consultation with Caterpillar, or
with the Dealer Solutions Network. This consultation may greatly reduce repair time. If the
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
ECM needs to be replaced, see Testing and Adjusting, "Electronic Control Module (ECM) -
Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:24:11 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i02488123
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 1 g01242503
This diagnostic code is associated with the Engine Coolant Temperature Sensor.
Note: This diagnostic code comes to the Machine ECM from the Engine ECM through the Cat Data
Link. First check for an Engine ECM diagnostic code MID 036 CID 0110 FMI 04. Diagnose this or
any other diagnostic code before attempting to diagnose the MID 039 CID 0110 FMI 04 diagnostic
code from the Machine ECM. For additional Engine ECM information refer to Troubleshooting,
RENR 5089, "MID 036 CID 0110 FMI 04".
This diagnostic code is recorded when the monitoring system reads a low sensor signal. When this
diagnostic code occurs, the gauge indicates an abnormally high value. The following symptoms could
cause the diagnostic code:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Note: The monitoring system is unable to determine when a sensor is open. Also, the monitoring
system is unable to determine when a harness for the sensor signal is open. This condition is
recognized when the gauge constantly indicates a value at the far left side of the scale.
Service Notes: Ensure that the desired diagnostic code is on hold. Ensure that the code is active. The
schematic that is shown above represents a typical installation of the component. Verify the connector
contact and wire numbers by using the Electrical System Schematic for the machine that is being
serviced.
A. Turn the disconnect switch and the key start switch to the ON position.
C. Disconnect the machine harness from the sensor that is causing the diagnostic code.
Expected Result:
Results:
• YES - The diagnostic code indicator stays ON. The harness wiring or the monitoring system
has failed. Proceed to test step 2.
• NO - The diagnostic code indicator turns OFF. The sensor has failed.
STOP
A. The disconnect switch and the key start switch remain in the ON position.
B. At the machine harness for the sensor, measure the voltage between the frame ground and the
sensor signal wire.
Expected Result:
Results:
• 6.0 ± 0.5 DCV - The voltage is 6.0 ± 0.5 DCV. The voltage is correct. Verify that the
diagnostic code remains.
Repair: It is unlikely that the monitoring system has failed. Exit this procedure and perform
this procedure again. Also, recheck if the diagnostic code indicator is illuminated for this
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
diagnostic code. If the cause of the diagnostic code is not found, replace the monitoring system.
See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• LESS THAN 0.5 DCV - The voltage is less than 0.5 DCV. The harness wiring has failed.
There is an open circuit or a short to ground in the signal wire for the sensor.
Repair: Repair the harness or replace the harness. Exit this procedure and perform this
procedure again. Also, recheck if the diagnostic code indicator is illuminated for this diagnostic
code. It is unlikely that the monitoring system has failed. If the cause of the diagnostic code is
not found, replace the monitoring system. See Testing and Adjusting, "Electronic Control
Module (ECM) - Replace".
STOP
• NOT 6.0 BUT ABOVE 0.5 DCV - The voltage is less than 0.5 DCV. The harness wiring has
failed. There is an open circuit or a short to ground in the signal wire for the sensor.
Repair: Repair the harness or replace the harness. Exit this procedure and perform this
procedure again. Also, recheck if the diagnostic code indicator is illuminated for this diagnostic
code. It is unlikely that the monitoring system has failed. If the cause of the diagnostic code is
not found, replace the monitoring system. See Testing and Adjusting, "Electronic Control
Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:24:33 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 6
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03101426
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 6
Illustration 1 g01242503
This diagnostic code is associated with the "Engine Coolant Temperature" sensor.
This diagnostic code is recorded when the Machine ECM does not receive expected information
through the Cat Data Link from the Engine ECM. The possible causes of this diagnostic code are
listed below:
• The wires for the Cat Data Link to the Engine ECM are open or the wires are shorted.
Test Step 1. VERIFY THE HARDWARE AND THE SOFTWARE PART NUMBERS.
◦ The part number of the flash software for the Engine ECM
◦ The part number of the flash software for the Machine ECM
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 6
Note: Consult your Caterpillar Dealer for the correct part numbers of the flash software.
Expected Result:
Results:
Repair: The installed Engine ECM or the Machine ECM have the wrong part number or the
incorrect flash software is installed. Replace the Engine ECM or replace the Machine ECM that
is incorrect. Replace the ECM with a module that has the correct part number. Flash the correct
software. See Testing and Adjusting, "Electronic Control Module (ECM) - Flash Program" for
additional information.
STOP
B. Inspect all harness connections that are related to the Cat Data Link. Make sure that the
connectors are clean and tight.
C. Check the connectors for proper mating. Ensure that all the seals are present and in place.
E. Check the wires at the connector. Ensure that the wires are secured tightly into the connector.
Take care not to pull the wire out of the connector.
F. Check the exposed wires at the connectors for nicks or signs of abrasion.
I. Check each pin and each socket of the machine harness connectors. Ensure that the contacts are
properly installed. The contacts should mate correctly when the two pieces of the connector are
placed together.
Expected Result:
The connectors of the machine harness are tight and free of corrosion.
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 6
• OK - The connectors of the machine harness are tight and free of corrosion. Proceed to Test
Step 3.
STOP
B. Disconnect the connectors of the machine harness from all electronic control modules that use
the Cat Data Link.
C. At the machine harness connector for the Machine ECM, measure the resistance between
connector contact J1-33 (wire 893-GN) and all of the contacts that are used in the machine
harness connector for the ECM. Perform the same measurements for J1-43 (wire 892-BR).
Expected Result:
Results:
• OK - Each of the resistance measurements is greater than 5000 ohms. The harness circuit
resistance is correct. Proceed to Test Step 4.
• NOT OK - One of the resistance measurements is less than 5000 ohms. The machine harness
has failed.
Repair: There is a short between the Cat contacts of the Data Link (wires 893-GN and 892-
BR) of the Cat Data Link and the circuit with the low resistance measurement. Repair the
machine harness or replace the machine harness.
STOP
B. All related electronic control modules remain disconnected from the machine harness.
C. Check the resistance of the Cat Data Link circuit in the machine harness:
◦ Measure the resistance between connector contact J1-8 (wire 893-GN) of the Engine
ECM and connector contact J1-33 (wire 893-GN) of the Machine ECM.
◦ Measure the resistance between connector contact J1-9 (wire 892-BR) of the Engine
ECM and connector contact J1-43 (wire 892-BR) of the Machine ECM.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 6
Results:
• OK - The resistance is less than 5 ohms. The Cat Data Link circuit in the machine harness is
correct. Proceed to Test Step 5.
• NOT OK - The resistance is greater than 5 ohms. The machine harness has failed.
Repair: The Cat Data Link circuit is open in the machine harness. Repair the machine harness
or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0110 FMI 09 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0110 FMI 09 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 6
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:24:57 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05455410
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Illustration 1 g03445416
This diagnostic code is associated with the "Alternator Charging Voltage" sensor. The FMI 12
diagnostic code means that the ECM has determined that the signal (frequency) of the sensor is below
the normal range.
This diagnostic code is recorded when the Machine ECM does not receive expected information from
the "Monitor Display". The possible causes of this diagnostic code are listed below:
• Harness wires for the "CAN Data Link" to the Machine ECM are open or the wires are shorted.
Note: Check the "R" term voltage at the alternator and all of the ECM contacts with the wire 403-GN.
All "R" term voltage checks should match. If one voltage is missing check for an open harness to that
ECM, see Test Step 4.
Test Step 1. VERIFY THE HARDWARE AND THE SOFTWARE PART NUMBERS
◦ The part number of the flash software for the Machine ECM
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
Note: Consult your Caterpillar dealer for the correct part numbers of the flash software.
Expected Result:
Results:
Repair: The installed Machine ECM has the wrong part number or the incorrect flash software
is installed. Replace the Machine ECM that is incorrect. Replace the ECM with a module that
has the correct part number. Flash the correct software. See Testing and Adjusting, "Electronic
Control Module (ECM) - Flash Program" for additional information.
STOP
B. Inspect all harness connections that are related to the "CAN Data Link". Make sure that the
connectors are clean and that the connectors are tight.
C. Check the connectors for proper mating. Ensure that all the seals are present and in place.
E. Check the wires at the connector. Ensure that the wires are secured tightly into the connector.
Take care not to pull the wire out of the connector.
F. Check the exposed wires at the connectors for nicks or signs of abrasion.
I. Check each pin and each socket of the machine harness connectors. Ensure that the contacts are
properly installed. The contacts should mate correctly when the two pieces of the connector are
placed together.
Expected Result:
Results:
• OK - The machine harness connectors are tight and free of corrosion. Proceed to Test Step 3.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
STOP
B. Disconnect the machine harness connectors from all electronic control modules that use the
"CAN Data Link".
C. At the machine harness connector for the Machine ECM, measure the resistance between
connector contact J2-50 (wire 251-YL) and all of the contacts that are used in the machine
harness connector for the ECM. Perform the same measurements for J2-51 (wire 261-GN).
Expected Result:
Results:
• OK - Each of the resistance measurements is greater than 5000 ohms. The harness circuit
resistance is correct. Proceed to Test Step 4.
• NOT OK - One of the resistance measurements is less than 5000 ohms. The machine harness
has failed.
Repair: There is a short between contacts J2-50 (wire 251-YL) or J2-51 (wire 261-GN) of the
CAN Data Link and the circuit with the low resistance measurement. Repair the machine
harness or replace the machine harness.
STOP
B. All related electronic control modules remain disconnected from the machine harness.
C. Check the resistance of the "CAN Data Link" circuit in the machine harness following the
process below:
◦ Measure the resistance between connector contact 5 in CN-1 connector (wire 251-YL) of
the Monitor Display and connector contact J2-50 (wire 251-YL) of the Machine ECM.
◦ Measure the resistance between connector contact 6 in CN-1 connector (wire 261-GN) of
the Monitor Display and connector contact J2-51 (wire 261-GN) of the Machine ECM.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
• OK - The resistance is less than 5 ohms. The "CAN Data Link " circuit in the machine harness
is correct. Proceed to Test Step 5.
• NOT OK - The resistance is greater than 5 ohms. The machine harness has failed.
Repair: The "CAN Data Link" circuit is open in the machine harness. Repair the machine
harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the contacts.
C. Turn the disconnect switch and the starter keyswitch to the ON position.
Expected Result:
Results:
• YES - The CID 0167 FMI 12 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: ECM failure is unlikely. Perform this procedure again. If the cause of the diagnostic
code is not found, contact your dealer Technical Communicator (TC) for possible consultation
with Caterpillar. This consultation may greatly reduce repair time and expense. if the ECM
must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) -
Replace".
STOP
• NO - The CID 0167 FMI 12 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The diagnostic code was probably caused by a poor electrical connection or a short at
one of the harness connectors that was disconnected and reconnected. Resume normal machine
operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:25:16 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03754249
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 1 g02025075
This diagnostic code is recorded when the ECM detects that the current output of the alternator is
below the expected level.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
B. Enter the diagnostic menu on the monitor. Observe the status of the diagnostic code.
Expected Result:
Results:
Expected Result:
Results:
• NO - The diagnostic code is active. The charging system is not charging at the proper level.
Repair: If the engine low idle speed is too low, the alternator may not be producing the
required output. Ensure that the engine low idle speed is correct and perform this test again. If
the diagnostic code is still active, a charging system component may be defective. Check the
charging system. See Special Instruction, REHS0354, "Charging System Troubleshooting" for
more information.
STOP
A. Turn the disconnect switch and the key switch to the OFF position.
B. Disconnect the connector from the Gateway Worldview Module ECM. Disconnect wire 403-
GN from the alternator "R" terminal.
C. Measure the resistance of wire 403-GN between the Gateway Worldview Module ECM harness
connector contact 54 and the disconnected wire 403-GN at the alternator.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
• YES - The resistance measures 5 ohms or less. The machine harness appears to be correct.
Either the alternator is not working correctly or the ECM may be recording this diagnostic code
incorrectly.
Repair: Check the charging system. See Special Instruction, REHS0354, "Charging System
Troubleshooting" for more information. If the charging system checks are correct, the ECM
may have failed. It is unlikely that the ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is NOT found, replace the ECM. See
Testing and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The resistance measurement is greater than 5 ohms. Wire 403-GN between the ECM and
the alternator is open in the machine harness.
Repair: Refer to the machine electrical schematic and ensure that all harness connectors in the
circuit are tight and in good condition. Repair the machine harness or replace the machine
harness.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:25:28 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04161813
Illustration 1 g02025091
This diagnostic code is for the Ambient Air Temperature sensor. An FMI 03 diagnostic code means
the machine ECM has determined the sensor output signal voltage is above the normal limit.
• Failed sensor.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 0171 FMI 03 is
still active, before performing the following procedures.
System Response:
This failure may cause ambient air temperature to indicate the maximum temperature. The failure
may also cause hydraulic oil temperature to indicate the maximum temperature, intermittently.
A. Turn the disconnect switch and the key start switch to the "ON" position.
C. In the machine harness connector for the Ambient Air Temperature sensor, measure the voltage
between the contact for terminal A (wire A760-GY) and the contact for terminal B (wire 235-
BK) in the sensor connector.
Expected Result:
Results:
• YES - The voltage is 8.0 ± 0.5 DCV. The power supply is not the problem. Go to Test Step 2.
• NO - The voltage is not 8.0 ± 0.5 DCV. There is a problem with the +8 DCV power supply.
Repair: Refer to the complete electrical schematics for the machine. Investigate and repair the
ECM +8 DCV power supply problem.
After +8 DCV power supply problem is repaired, check if the 0171 FMI 03 diagnostic code is
still active. If the diagnostic code is still active, proceed to Test Step 2.
Test Step 2. CHECK THE SENSOR, THE ECM, AND THE MACHINE HARNESS.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the Ambient Air Temperature sensor.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
C. In the harness connector for the sensor, place a jumper wire between the contact for terminal C
(wire N789-BU) and the contact for terminal B (wire 235-BK) in the sensor connector.
D. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 0171 FMI 03 diagnostic code remains active. The sensor is not the problem.
Go to Test Step 3.
• NO - The CID 0171 FMI 03 diagnostic code is no longer active. The diagnostic code has been
replaced by an active CID 0171 FMI 04 diagnostic code. The sensor has failed.
Go to Test Step 5.
A. Turn the disconnect switch and the key start switch to the OFF position.
D. Disconnect both the J1 and J2 harness connector from the machine ECM.
E. At the ECM J1 harness connector, measure the resistance between contact J1-4 (N789-BU) and
contact J1-2 (235-BK) in the J1 harness connector.
Note: An Ambient Air Temperature sensor Ground Return is also found at contact J1-14
(235-BK). Always check these parallel ground wires. Make sure to repair or replace any
that are found open.
Expected Result:
Results:
Repair: The machine harness has failed. There is an open circuit in the machine harness.
Repair or replace the harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
Go to Test Step 5.
A. The disconnect switch and the key start switch remain in the OFF position.
D. At the J1 ECM harness connector measure resistance from contact J1-4 (wire N789-BU) to all
the other contacts used in both the J1 and J2 ECM harness connectors.
Expected Result:
Results:
• YES - All measurements are more than 5000 ohms. Go to Test Step 5.
• NO - All measurements are not more than 5000 ohms. There is a short circuit in the machine
harness.
Go to Test Step 5.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 0171 FMI 03 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
• NO - The CID 0171 FMI 03 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 5 again. If the
problem was again not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:25:45 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04161814
Illustration 1 g02025091
This diagnostic code is for the Ambient Air Temperature sensor. An FMI 04 indicates the machine
ECM has determined the sensor output signal voltage is below the normal limit.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 0171 FMI 04 is
still active, before performing the following procedures.
System Response:
This failure may cause the Ambient Air Temperature sensor to indicate a maximum temperature,
either constantly, or intermittently.
Test Step 1. CHECK THE SENSOR THE ECM, AND THE MACHINE HARNESS.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the machine harness connector from the Ambient Air Temperature sensor.
C. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 0171 FMI 04 code remains active. The sensor is not the problem. Go to Test
Step 2.
• NO - The CID 0171 FMI 04 code is no longer active and has been replaced by an active CID
0171 FMI 04 diagnostic code. The sensor has failed.
Go to Test Step 3.
Test Step 2. CHECK THE SENSOR OUTPUT WIRE FOR A GROUND SHORT.
A. Turn the disconnect switch and the key start switch to the OFF position.
C. Disconnect both the J1 and J2 ECM harness connectors from the ECM.
D. At the J1 harness connector for the ECM, measure the resistance from contact J1-4 (N789-BU)
to all of the other contacts used in both the J1 and J2 ECM harness connectors.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
STOP.
Results:
• NO - A resistance is less than 5000 ohms. There is a short circuit in the machine harness.
Go to Test Step 3.
A. Reconnect all harness connectors. Make sure that all connectors are fully seated. Observe that
the clips for each connector are securely fastened.
B. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0171 FMI 04 code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 0171 FMI 04 diagnostic code is still active. The problem has not been corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Caterpillar Electronic Technician service tool.
The "wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are securely fastened. Perform Test Step 3 again. If
the problem has NOT been found, and this diagnostic code is still active, the ECM may have
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:26:12 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05259917
Illustration 1 g02025148
This diagnostic code is for the Engine Speed sensor. This sensor is located near the top of the
flywheel housing.
The Machine ECM monitors the input signals from the speed sensor in order to determine the rotation
speed of the flywheel. The frequency of the sensor output signal varies as the teeth on the flywheel
pass the sensor. The frequency of the sensor output signal is proportional to the speed of the flywheel.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
An FMI 8 diagnostic code indicates the machine ECM has determined the sensor output signal has an
abnormal frequency, pulse width, or period.
• Open wire connections or intermittent open connections in the speed sensor circuit
• Shorted wire connections or intermittent shorted connections in the speed sensor circuit
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that the 190-8 diagnostic code is still
active, before performing the following procedures.
Note: The engine must be running in order for this diagnostic code to be active.
B. Disconnected the machine harness connector from the Engine Speed sensor.
C. In the harness connector for the sensor, place a jumper wire between the contact for terminal 1
(wire 788-YL) and the contact for terminal 2 (wire A762-PU) in the sensor connector.
D. Disconnect both the J1 and J2 harness connectors from the machine ECM.
E. At the J2 ECM harness connector, measure the resistance between contact J2-16 (wire 788-YL)
and contact J2-25 (wire A762-PU) of the J2 ECM harness connector.
Expected Result:
Results:
• NO - The resistance is not less than 5 ohms. There is an open wire in the sensor circuit.
Go to Test Step 4.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
A. The disconnect switch and the key start switch remain in the OFF position.
D. At the J2 ECM harness connector, measure resistance from contact J2-16 (wire 788-YL) to all
the other contacts used in both the J1 and J2 ECM harness connectors.
E. Again at the J2 ECM harness connector, measure resistance from contact J2-25 (wire A762-
PU) to all the other contacts used in both the J1 and J2 ECM harness connectors.
Expected Result:
Results:
• YES - All measurements are more than 5000 ohms. Go to Test Step 4.
• NO - All measurements are not more than 5000 ohms. There is a short circuit in the harness.
Go to Test Step 3.
A. The keyswitch and the disconnect switch remain in the OFF position.
B. Remove and inspect the sensor. Perform the adjustment procedure . See Testing and Adjusting,
"Speed Sensor - Adjust" and follow the inspection and adjustment steps.
Note: Replace the sensor if the magnetic pickup tip looks damaged or has metal embedded into
the tip. If damage can be seen to the gear teeth, remove the pump for further inspection of the
flywheel and rear gear train. Refer to Disassembly and Assembly, "Pump Drive Group -
Remove".
C. If suspect, replace the sensor and perform the adjustment for the replacement sensor.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
• OK - The diagnostic code moves from active to logged. Sensor failure / incorrect adjustment
was the cause of the fault.
STOP
Repair: Reinstall the original sensor. Refer to Testing and Adjusting, "Speed Sensor - Adjust"
to repeat the procedure.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The 190-8 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The 190-8 diagnostic code is still active. The problem has not been corrected. The ECM
may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing. Refer to Testing and Adjusting , "Electrical
Connector - Inspect ".Perform a 45 N (10 lb.) pull test on each of the wires that are associated
with the sensor circuit. Perform a "wiggle test" on the sensor circuit of the machine wiring
harness, using the Caterpillar Electronic Technician service tool. The "wiggle test" can be used
to detect open or shorted connections in the machine wiring harness. Reconnect all harness
connectors. Make sure that the connectors are fully seated. Observe that the clips for each
connector are fastened. Perform Test Step 5 again. If the problem was again not found, and the
original code is still active, the machine ECM may have failed.Prior to replacing an ECM,
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
always contact your Dealership Technical Communicator for possible consultation with
Caterpillar®. This consultation may greatly reduce repair time. If the ECM needs to be replaced,
see Testing and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:26:29 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03996494
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 1 g01242599
This diagnostic code is recorded when the Monitor does not receive expected information from the
machine ECM for more than 5 seconds.
For machines equipped with the E-Fence feature, reference Troubleshooting, "E-Ceiling and
Cab Avoidance - Troubleshoot"
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1130 FMI 04 is
still active, before performing the following procedures.
System Response:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
This failure results in events that are logged against an ECM that cannot be explained directly. The
Monitor cannot communicate with the Machine ECM, or the ECM appears to communicate
intermittently with the Monitor.
A. The key start switch and the disconnect switch remain in the OFF position.
B. Disconnect the machine harness from all electronic control modules that use the CAN Data
Link.
C. At the machine harness connector for the ECM, measure the resistance between the frame
ground and the CAN Data Link circuits (contacts J2-50 and J2-51).
Expected Result:
Results:
• YES - The resistance is greater than 5000 ohms. The harness circuit resistance is correct.
Proceed to Test Step 2.
Repair: The machine harness has failed. There is a short between the CAN Data Link circuit
and frame ground in the machine harness. Repair, or replace, the machine harness.
STOP
A. The key start switch and the disconnect switch remain in the OFF position.
B. All related control modules remain disconnected from the machine harness.
C. At the harness for the ECM, measure the resistance between the +battery circuit (contact J1-1)
and the CAN Data Link (contacts J2-50 and J2-51).
Expected Result:
Results:
• OK - The resistance is greater than 5000 ohms. The harness circuit resistance is correct.
Proceed to Test Step 3.
Repair: The harness has failed. There is a short between the +battery contact and the CAN
Data Link circuit in the machine harness. Repair, or replace, the machine harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
A. The key start switch and the disconnect switch remain in the OFF position.
B. All related control modules remain disconnected from the machine harness.
C. Check the continuity of the CAN Data Link circuit in the machine harness.
D. Measure the resistance between the contact J2-50 of the Machine ECM (wire 251-YL) and the
corresponding connection (wire 251-YL) of the switch panel. Measure the resistance between
the Machine ECM and the connection of the Monitor.
E. Measure the resistance from contact J2-51 (wire 261-GN) and the corresponding connection
(wire 261-GN) of the switch panel and the "Monitor".
Expected Result:
Results:
Repair: The CAN Data Link circuit in the machine harness is correct. The ECM has failed. Is
unlikely that the ECM has failed. If you have not inspected the harness connectors in a previous
Test Step, do that now. Clean the contacts of the harness connectors. Check the wires for
damage to the insulation caused by excessive heat, battery acid, or chafing.Perform a 45 N (10
lb.) pull test on each of the wires that are associated with the solenoid circuit.Perform a "wiggle
test" on the solenoid circuit of the machine wiring harness, using the Caterpillar Electronic
Technician service tool. The "wiggle test" can be used to detect open or shorted connections in
the machine wiring harness.Reconnect all harness connectors. Make sure that the connectors
are fully seated. Observe that the clips for each connector are securely fastened. Perform Test
Step 4 again. If the problem has NOT been found, and this diagnostic code is still active, the
ECM may have failed.Prior to replacing an ECM, always contact your Dealership Technical
Communicator for possible consultation with Caterpillar, or with the Dealer Solutions Network.
This consultation may greatly reduce repair time. If the ECM needs to be replaced, see Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
Repair: The machine harness has failed. The CAN Data Link circuit is open in the machine
harness. Repair, or replace, the machine harness.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:26:51 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 1
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i02414869
• The Electronic Control Module (ECM) detects an unexpected loss of a continuous J1939 speed
signal on the J1939 data link.
• The expected continuous speed signal has never been received on the J1939 data link.
Check the configuration of the ECM. If the ECM for the engine has been incorrectly configured to
expect a continuous J1939 speed signal, remove "Continuous" for the J1939 speed signal on the main
"J1939" screen on the electronic service tool.
Results:
• OK - STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:27:11 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03917813
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Illustration 1 g01599614
This diagnostic code is recorded when the ECM does not receive expected information. The
information from the Cat Data Link indicates the abnormal values in the readout. The possible causes
of this diagnostic code are listed below. The causes are listed in order of probability:
For machines equipped with the E-Fence feature, reference Troubleshooting, "E-Ceiling and
Cab Avoidance - Troubleshoot"
• The circuit for the Cat Data Link in the machine harness is shorted to ground.
• The circuit for the Cat Data Link in the machine harness is shorted to a power supply source.
• The circuit for the Cat Data Link in the machine harness is open.
System Response:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
Note: The Machine ECM is equipped with LED indicators that serve as a self-diagnostic check. With
the key start switch in the ON position, the technician can observe the status of the indicator lights. If
the technician observes that all of the LED lights are OFF, power is not being supplied to the Machine
ECM. The technician should proceed to check the power supply to the Machine ECM. If the
technician observes that the yellow LED is ON, a communication error exists at the "CAN1" circuit.
The Machine ECM may not be loaded with software if the yellow LED is flashing. The Machine
ECM must be replaced if the red LED is flashing.
A. Check for other diagnostic codes that are related to the Cat Data Link.
Expected Result:
Results:
• YES - Exit this procedure and perform the other procedures for the diagnostic codes that are
shownSTOP
• NO - There are not any other diagnostic codes that are shown. Proceed to Test Step 2.
B. Inspect the connections for the machine harness that are related to the Cat Data Link.
Expected Result:
Results:
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
B. Disconnect the machine harness from all the electronic control modules that use the Cat Data
Link.
C. At the machine harness connector for the ECM, measure the resistance between frame ground
and the circuits of the Cat Data Link, contacts J1-33 (wire 893-GN) and J1-43 (wire 892-BR).
Expected Result:
Results:
• YES - The resistance is greater than 5000 ohms. The harness circuit resistance is correct.
Proceed to Test Step 4.
• NO - The resistance is less than 5000 ohms. The machine harness has failed. There is a short
between the frame ground and the Cat Data Link circuit in the machine harness.
STOP
B. All related control modules remain disconnected from the machine harness.
C. At the machine harness connector for the ECM, measure the resistance between the +battery
circuit J1-1 and J1-13 (wire 184-RD) and the circuits of the Cat Data Link, contacts J1-33 (wire
893-GN) and J1-43 (wire 892-BR).
Expected Result:
Results:
• OK - The resistance is greater than 5000 ohms. The harness circuit resistance is correct.
Proceed to Test Step 5.
• NOT OK - The resistance is less than 5000 ohms. The machine harness has failed. There is a
short circuit. The short circuit is between the +battery and the circuit for the "Cat Data Link" in
the machine harness.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
B. All related control modules remain disconnected from the machine harness.
C. Check the continuity of the Cat Data Link circuit in the machine harness.
D. Measure the resistance from the connector contacts J1-33 (wire 893-GN) and J1-43 (wire 892-
BR) of the ECM to the connector for each of the related circuits for the other electronic control
modules.
Expected Result:
Results:
• YES - The resistance is less than 5 ohms. The Cat Data Link circuit in the machine harness is
correct.
Repair: Is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. Also, recheck if the diagnostic code is active. If the cause of the diagnostic code is not
found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) -
Replace".
STOP
• NO - The resistance is greater than 5 ohms. The machine harness has failed. The Cat Data Link
circuit is open in the machine harness.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:27:27 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 1
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03917949
This diagnostic code is recorded when the ECM reads a problem that is internal to the ECM.
For machines equipped with the E-Fence feature, reference Troubleshooting, "E-Ceiling and
Cab Avoidance - Troubleshoot"
Test Step 1.
Results:
Repair: Replace the Machine ECM. See Testing and Adjusting, "Electronic Control Module
(ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:27:41 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04161815
Illustration 1 g02356600
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is for the ECM +5 VDC sensor supply. An FMI 06 indicates the ECM has
determined the current of the ECM +5 VDC Sensor supply circuit is above normal.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 0262 FMI 06 is
still active, before performing the following procedures.
System Response:
Components that receive power from the +5 VDC sensor supply will not be available.
A. Turn the disconnect switch and the key start switch to the ON position.
B. Do not disconnect any of the machine harnesses at this time. Check for +5 VDC at the harness
connector of every sensor suplied by the ECM +5 VDC power supply.
Expected Result:
Results:
• YES - The voltage at each sensor is 5.0 ± 0.5 DCV. Check if the diagnostic code is still active.
If the code is still active, go to Test Step 2.
• NO - The voltage at one or more of the sensors is not 5.0 ± 0.5 DCV. There is a problem with
the ECM +5 VDC voltage supply.
Repair: Refer to the complete electrical schematics for the machine. Investigate and repair the
+5 VDC power supply problem.
After +5 DCV power supply problem is repaired, check if the 0262 FMI 06 diagnostic code is
still active. If the diagnostic code is still active, goo to Test Step 2.
A. Turn the disconnect switch and the key start switch to the ON position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
B. One at a time disconnect and reconnect each and every sensor supplied by the ECM +5 VDC
sensor power supply.
C. While each sensor is disconnected, check the status of the CID 0262 FMI 06 diagnostic code.
Expected Result:
The CID 0262 FMI 06 diagnostic code remains active while each sensor is disconnected and
reconnected.
Results:
• YES - The CID 0262 FMI 06 diagnostic code remains active while each sensor is disconnected
and reconnected. None of the sensors are causing the problem. Go to Test Step 3.
• NO - While one of the sensors is disconnected, the CID 0262 FMI 06 diagnostic code becomes
inactive. That sensor is causing the problem.
Go to Test Step 4.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect both the J1 and J2 ECM harness connectors from the machine ECM.
C. At the J1 machine harness connector for the ECM, measure resistance from contact J1-5
(sensor supply) A760-GY to all possible sources of ground in both the J1 and J2 ECM harness
connectors.
Expected Result:
Results:
• YES - Each resistance measurement is greater than 5000 ohms. Go to Test Step 4.
• NO - A resistance measurement is less than 5000 ohms. There is a short circuit in the machine
harness.
Go to Test Step 4.
A. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are securely fastened.
B. Turn the disconnect switch and the key start switch to the ON position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Expected Result:
Results:
• YES - The CID 0262 FMI 06 diagnostic code is no longer active. The code does not exist at
this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 0262 FMI 06 diagnostic code is still active. The problem has not been corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 4 again. If the
problem has again not been found, and the original code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:28:02 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755057
Illustration 1 g02025266
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is recorded when the "Monitor" module determines that the current of the action
alarm is above normal. The "Monitor" module indicates the fault to the Machine ECM over the CAN
Data Link.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0271 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the action alarm with the active diagnostic code from the machine harness.
Expected Result:
The status of CID 0271 FMI 06 diagnostic code changes when the action alarm is disconnected.
Results:
• YES - The status of CID 0271 FMI 06 diagnostic code changes when the action alarm is
disconnected. The circuit is correct.
Repair: The action alarm has failed. Repeat this test "CHECK THE ACTION ALARM" in
order to verify the failure of the action alarm. Replace the action alarm.
STOP
• NO - The CID 0271 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE ACTION ALARM FOR A SHORT
TO GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact 12 (wire 410-
WH) to all contacts that are used in the connectors of the machine harness for the ECM.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between contact 12 (wire 410-WH) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0271 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the "Monitor" module has failed. Exit this procedure and perform
this procedure again. Refer to the Electrical System Schematic for this machine and check all
involved wiring harness connectors and wiring. Ensure that the connector contacts are clean
and that the connector contacts are in good condition. Ensure that all wiring of the machine
harness is intact and that all wiring of the machine harness is in good condition. If the cause of
this diagnostic code is not found, replace the "Monitor" module.
STOP
• NO - The CID 0271 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:28:18 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04450529
Illustration 1 g02638020
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
This diagnostic code is associated with the "Variable Fan Speed Control" Solenoid. The FMI 03
means that the ECM has determined that the voltage of the solenoid circuit is above normal. The
solenoid is within the "ATCH Viscus Clutch".
Note: The Machine ECM is equipped with LED indicators that serve as a self-diagnostic check. With
the key start switch in the ON position, the technician can observe the status of the indicator lights. If
the technician observes that all of the LED lights are OFF, power is not being supplied to the Machine
ECM. The technician should proceed to check the power supply to the Machine ECM. If the
technician observes that the yellow LED is ON, a communication error exists at the "CAN1" circuit.
The Machine ECM may not be loaded with software if the yellow LED is flashing. The Machine
ECM must be replaced if the red LED is flashing.
Before performing this procedure, inspect the harness connectors that are involved in the
circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that
all connections in the circuit are clean, that all connections are secure and that all connections
are in good condition. If a problem with a connection is found, correct the problem and verify
that this diagnostic code is active before performing this procedure.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0291 FMI 03 is active before performing this procedure.
System Response:
Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
THE +BATTERY CIRCUIT.
A. Turn the key start switch and the disconnect switch to the ON position.
Note: Use a wire removal tool to remove the appropriate wires from the machine harness
connector for the ECM.
B. Remove the wire for the solenoid signal (H746-YL) of the connector contact J1-7 for the
Machine ECM.
C. Measure the voltage from the wire for the solenoid signal (H746-YL) to frame ground.
D. Remove the wire for the solenoid return (A209-BK) of the connector contact J2-18 for the
Machine ECM.
E. Measure the voltage from the wire for the solenoid return (A209-BK) to frame ground.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - The voltage is 0 VDC. There are no shorts in the wires. Proceed to Test Step 2.
• NOT OK - There is the presence of a voltage in a wire. The short is in the wire with a
measured voltage. The machine harness has failed.
STOP
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0291 FMI 03 is active. The problem has not been corrected. The ECM may
have failed.
Repair: If the cause of the problem is not found, contact the Technical Communicator for your
dealership for possible consultation with Caterpillar. This consultation may greatly reduce
repair time. If the ECM requires replacement, see Troubleshooting, "Electronic Control Module
(ECM) - Replace".
STOP
• NO - The CID 0291 FMI 03 is not active. The problem does not exist at this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:28:32 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04450549
Illustration 1 g02638020
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is associated with the "Variable Fan Speed Control" Solenoid. The FMI 05
indicates that the ECM has determined that an open connection exists in the circuit for the solenoid.
This solenoid is located within the "ATCH Viscus Clutch".
Note: The Machine ECM is equipped with LED indicators that serve as a self-diagnostic check. With
the key start switch in the ON position, the technician can observe the status of the indicator lights. If
the technician observes that all of the LED lights are OFF, power is not being supplied to the Machine
ECM. The technician should proceed to check the power supply to the Machine ECM. If the
technician observes that the yellow LED is ON, a communication error exists at the "CAN1" circuit.
The Machine ECM may not be loaded with software if the yellow LED is flashing. The Machine
ECM must be replaced if the red LED is flashing.
Before performing this procedure, inspect the harness connectors that are involved in the
circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that
all connections in the circuit are clean, that all connections are secure and that all connections
are in good condition. If a problem with a connection is found, correct the problem and verify
that this diagnostic code is active before performing this procedure.
Note: The following procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected.Ensure
that the diagnostic code of CID 0291 FMI 05 is active before performing this procedure.
System Response:
A. Turn the disconnect switch and the key start switch to the ON position. DO NOT start the
engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the "ATCH Viscus Clutch", place a jumper wire from
contact 3 (wire H746-YL) to contact 2 (wire A209-BK).
Expected Result:
The CID 0291 FMI 05 remains active when the jumper wire is installed.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Results:
• YES - The diagnostic code of FMI 05 is active. The jumper wire does not affect the diagnostic
code. Proceed to Test Step 2.
Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous Test Step remains.
D. At the machine harness connector for the ECM, measure the resistance from signal contact J1-7
(wire H746-YL) to contact J2-18 (wire A209-BK).
Expected Result:
Results:
• OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step
3.
• NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open connection is in the wire with the resistance that is measured at more than
5000 ohms. The open is in either signal wire (H746-YL) or return wire (A209-BK) of the
machine harness. Repair the machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Expected Result:
Results:
• YES - The CID 0291 FMI 05 is active. The diagnostic code has not been corrected. The ECM
may have failed.
Repair: If the cause of the problem is not found, contact the Technical Communicator for your
dealership for possible consultation with Caterpillar. This consultation may greatly reduce
repair time. If the ECM requires replacement, see Troubleshooting, "Electronic Control Module
(ECM) - Replace".
STOP
• NO - The CID 0291 FMI 05 is not active. The diagnostic code does not exist at this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection at one
of the harness connectors that was disconnected and reconnected. Resume normal machine
operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:28:56 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04450551
Illustration 1 g02638020
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is associated with the "Variable Fan Speed Control" solenoid. The FMI 06
means that the ECM has determined that there is a short to ground in the solenoid circuit. This
solenoid is located within the "ATCH Viscus Clutch".
Note: The Machine ECM is equipped with LED indicators that serve as a self-diagnostic check. With
the key start switch in the ON position, the technician can observe the status of the indicator lights. If
the technician observes that all of the LED lights are OFF, power is not being supplied to the Machine
ECM. The technician should proceed to check the power supply to the Machine ECM. If the
technician observes that the yellow LED is ON, a communication error exists at the "CAN1" circuit.
The Machine ECM may not be loaded with software if the yellow LED is flashing. The Machine
ECM must be replaced if the red LED is flashing.
Before performing this procedure, inspect the harness connectors that are involved in the
circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that
all connections in the circuit are clean, that all connections are secure and that all connections
are in good condition. If a problem with a connection is found, correct the problem and verify
that this diagnostic code is active before performing this procedure.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0291 FMI 06 is active before performing this procedure.
System Response:
A. Turn the disconnect switch and the key start switch to the ON position. DO NOT start the
engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
CID 0291 FMI 06 changes to CID 0291 FMI 05 when the solenoid is disconnected.
Results:
• YES - CID 0291 FMI 06 changes to CID 0291 FMI 05 when the solenoid is disconnected. The
circuit is correct.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J1-7 (wire
H746-YL) to all contacts that are used in the machine harness connectors for the ECM.
Expected Result:
Results:
• OK - Each resistance is greater than 5000 ohms. The machine harness is correct. Proceed to
Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between contact J1-7 (wire H746-YL) and the circuit with the
low resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors. Check the wires
for damage to the insulation that is caused by excessive heat, corrosion, or chafing.
B. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
C. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are completely fastened.
D. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Results:
• YES - The CID 0291 FMI 06 is active. The diagnostic code has not been corrected. The ECM
may have failed.
Repair: If the cause of the problem is not found, contact the Technical Communicator for your
dealership for possible consultation with Caterpillar. This consultation may greatly reduce
repair time. If the ECM requires replacement, see Troubleshooting, "Electronic Control Module
(ECM) - Replace".
STOP
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:29:08 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755083
Illustration 1 g02025271
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
This diagnostic code is associated with the "Radiator Fan Speed Viscus" clutch. The FMI 03
diagnostic code means that the ECM has determined that the voltage of the clutch circuit is above
normal.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0362 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
The diagnostic code of CID 0362 FMI 03 will be logged in the internal memory of the Machine
ECM.
Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE CLUTCH FOR A SHORT TO
THE +BATTERY CIRCUIT.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-24
(wire G834-PU) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-24 (G834-PU) and the circuit that has a low
resistance measurement.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0362 FMI 03 diagnostic code is active. The problem has not been corrected.
The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0362 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:29:26 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755194
Illustration 1 g02025271
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is associated with the "Radiator Fan Speed Viscus" clutch. The FMI 05
diagnostic code means that the ECM has determined that an open in the circuit exists.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0362 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the clutch with the active diagnostic code from the machine harness.
C. At the machine harness connector for the clutch, place a jumper wire from contact 1 (wire
G834-PU) to contact 2 (wire H747-BR).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The clutch has failed. Repeat this Test Step "CHECK THE CLUTCH" in order to
verify the clutch failure. Replace the clutch. Verify that the new clutch corrects the problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous Test Step remains in place.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
D. At the machine harness connector, measure the resistance from signal contact J2-24 (wire G834
-PU) to contact J2-22 (wire H747-BR).
Expected Result:
Results:
• OK - The resistance is less than 5 ohms. The machine harness is correct. Proceed to Test Step
3.
• NOT OK - The resistance is greater than 5 ohms. The resistance measurement is not correct.
There is an open circuit in the machine harness.
Repair: The open is in wire G834-PU or in wire H747-BR of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0362 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0362 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection at one
of the harness connectors that was disconnected and reconnected. Resume normal machine
operation.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:29:49 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755202
Illustration 1 g02025271
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is associated with the "Radiator Fan Speed Viscus" clutch. The FMI 06
diagnostic code means that the ECM has determined that there is a short to ground in the circuit.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0362 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the "Fan Speed Viscus" clutch from the machine harness.
Expected Result:
The CID 0362 FMI 06 diagnostic code changes to a CID 0362 FMI 05 diagnostic code when the
clutch is disconnected.
Results:
• YES - The CID 0362 FMI 06 diagnostic code changes to a CID 0362 FMI 05 diagnostic code
when the clutch is disconnected. The circuit is correct.
Repair: The clutch has failed. Repeat this test "CHECK THE CLUTCH" in order to verify the
clutch failure. Replace the clutch.
STOP
• NO - The CID 0362 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE CLUTCH FOR A SHORT TO
GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-24 (wire
G834-PU) to all contacts that are used in the machine harness connectors for the ECM.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-24 (wire G834-PU) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0362 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0362 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:30:03 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05422816
Illustration 1 g02166735
Schematic of the Swing Brake solenoid for machine models 311D, 312D, 314D, 315D, and 319D.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 2 g03422237
Schematic of the Swing Brake Cancel solenoid for machine models 312D2, 313D2, and 318D2. (Note change in signal
wire for this schematic.)
This diagnostic code is associated with the Swing Brake solenoid. An FMI 03 diagnostic code means
the ECM has determined the voltage of the solenoid circuit is above normal.
• The Swing Brake solenoid energize circuit has shorted to a voltage source.
• The Machine ECM may have failed, but this situation is unlikely.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem, and verify that diagnostic code CID 0374 FMI 03 is
still active, before performing the following procedures.
System Response:
Diagnostic code CID 0374 FMI 03 will be logged in the internal memory of the Machine ECM.
Test Step 1. CHECK THE SOLENOID, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the disconnect switch and the key start switch to the OFF position.
C. Disconnect the machine harness connector from the Swing Brake solenoid.
D. At the harness connector for the solenoid, place a jumper wire from contact 1 (K906-GN) to
contact 2 (235-BK) in the connector.
E. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• YES - The CID 0374 FMI 03 diagnostic code remains active. The jumper wire did not change
the code. The solenoid is NOT the cause of the problem
Repair: The machine harness has failed, or the ECM may have failed.
Go to Test Step 2.
• NO - The CID 0374 FMI 03 diagnostic code is no longer active, and has been replaced by an
active CID 0374 FMI 05 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness connections, are correct. The solenoid has failed. Perform
Test Step 1 again, to verify the solenoid failure. Replace the solenoid.
Go to Test Step 3
A. Turn the key start switch and the disconnect switch to the OFF position.
B. The harness connector remains disconnected from the Swing Brake solenoid.
D. Disconnect the J1 and J2 machine harness connectors from the Machine ECM.
E. At the ECM J2 harness connector, measure the resistance from contact J2-23 (K907-BU or
K906-GN) to all of the other contacts used in the ECM machine harness connectors.
Expected Result:
Results:
• YES - Each resistance is more than 5000 ohms. The machine harness is correct. Go to Test
Step 3.
• NO - Each resistance is NOT more than 5000 ohms. There is a short in the harness. The short is
between J2-23 (K907-BU or K906-GN) and the circuit with the low resistance measurement.
Go to Test Step 3.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
B. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are securely fastened.
D. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0374 FMI 03 code is not active. The code does not exist at this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
• NO - The CID 0374 FMI 03 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Caterpillar Electronic Technician service tool.
The "wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem has NOT been found, and this diagnostic code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:30:30 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 6
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05422904
Illustration 1 g02166735
Schematic of the Swing Brake solenoid for sales models 311D, 312D, 314D, 315D, and 319D.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 6
Illustration 2 g03422237
Schematic of the Swing Brake solenoid for machine models 312D2, 313D2, and 318D2.
This diagnostic code is associated with the Swing Brake solenoid. An FMI 05 diagnostic code means
the ECM has determined the current of the solenoid circuit is below normal.
• The Machine ECM may have failed, but this situation is unlikely.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 0374 FMI 05 is
still active, before performing the following procedures.
System Response:
Diagnostic code CID 0374 FMI 05 will be logged in the internal memory of the Machine ECM.
Test Step 1. CHECK THE SOLENOID, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the disconnect switch and the key start switch to the OFF position.
C. Disconnect the machine harness connector from the Swing Brake solenoid.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 6
D. At the harness connector for the solenoid, place a jumper wire from contact 1 (K906-GN) to
contact 2 (235-BK) on the connector.
E. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Expected Result:
Results:
• YES - The CID 0374 FMI 05 diagnostic code remains active. The jumper wire did not change
the code. The solenoid is NOT the cause of the problem.
Repair: The machine harness has failed, the Backup EPR Valve switch has failed (if
applicable), or the ECM may have failed.
Go to Test Step 2.
• NO - The CID 0374 FMI 05 diagnostic code is no longer active, and has been replaced by an
active CID 0374 FMI 06 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness connections, are correct. The solenoid has failed. Perform
Test Step 1 again, to verify the solenoid failure. Replace the solenoid.
Go to Test Step 5.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. The harness connector remains disconnected from the Swing Brake solenoid.
C. The jumper wire that was placed into the Swing Brake solenoid harness connector during Test
Step 1 remains in place.
E. Disconnect the J1 and the J2 machine harness connectors from the Machine ECM.
F. At the ECM harness connectors, measure the resistance from contact J2-23 (K907-BU or K906-
GN) to contact J1-2 (235-BK).
Note: A Swing Brake solenoid Ground Return is also found at contact J1-14 (235-BK).
Always check these parallel ground wires. Make sure to repair or replace any that are
found open.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 6
Results:
• YES - The resistance is less than 5 ohms. The machine harness, and the Backup EPR Valve
switch, are correct. Go to Test Step 5.
• NO - The resistance is NOT less than 5 ohms. There is an open in the harness, or the Backup
EPR Valve switch has failed, if applicable. Go to Test Step 3
Test Step 3. CHECK THE MACHINE HARNESS FOR AN OPEN CONNECTION (NOT
APPLICABLE FOR MODELS 312D2, 313D2, OR 318D2).
A. The key start switch and the disconnect switch remain in the OFF position.
B. Disconnect the machine harness connector from the Backup EPR Valve switch. The harness
connector remains disconnected from the Swing Brake solenoid. Remove the jumper wire
inserted during Test Step 1.
C. At the ECM J2 harness connector, measure the resistance from contact J2-23 (K907-BU) to
contact 3 (K907-BU) on the Backup EPR Valve switch harness connector.
D. At the Backup EPR Valve switch harness connector, measure the resistance from contact 2
(K906-GN) to contact 1 (K906-GN) on the Swing Brake solenoid harness connector.
E. At the Swing Brake solenoid harness connector, measure the resistance from contact 2 (235-
BK) to contact 10 (235-BK) on the Backup EPR Valve switch harness connector.
F. At the Backup EPR Valve switch harness connector, measure the resistance from contact 10
(235-BK) to contact J1-2 (235 -BK) on the ECM J2 harness connector.
Note: A Swing Brake solenoid Ground Return is also found at contact J1-14 (235-BK). Always
check these parallel ground wires. Make sure to repair or replace any that are found open.
Expected Result:
Results:
• YES - Each measurement is less than 5 ohms. The machine harness connections are correct.
The Backup EPR Valve switch may have failed. Go to Test Step 4.
• NO - Each measurement is NOT less than 5 ohms. There is an open circuit in the harness
connections for the solenoid circuit. The open is on the connection with the high resistance
measurement.
Go to Test Step 5.
Table 1
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 6
A. The starter key switch and the disconnect switch remain in the OFF position.
F. Again measure the resistance between contact 2 and contact 3 of the switch.
Expected Result:
Results:
• YES - Each measurement agrees with Table 1. The switch is correct. Go to Test Step 5.
• NO - Each measurement does NOT agree with Table 1. The switch has failed.
Go to Test Step 5.
B. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are fastened securely.
D. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 6
Results:
• YES - The CID 0374 FMI 05 diagnostic code is not active. The code does not exist at this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
• NO - The CID 0374 FMI 05 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Caterpillar Electronic Technician service tool.
The "wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 6 again. If the
problem has NOT been found, and this diagnostic code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:30:46 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05422914
Illustration 1 g02166735
Schematic of the Swing Brake solenoid for sales models 311D, 312D, 314D, 315D, and 319D.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 2 g03422237
Schematic of the Swing Brake solenoid for models 312D2, 313D2, and 318D2.
This diagnostic code is associated with the Swing Brake solenoid. An FMI 06 diagnostic code means
the ECM has determined the current of the solenoid circuit is above normal.
• The Machine ECM may have failed. A failure of the Machine ECM is unlikely.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem, and verify that diagnostic code CID 0374 FMI 06 is
still active, before performing the following procedures.
System Response:
Diagnostic code CID 0374 FMI 06 will be logged in the internal memory of the Machine ECM.
Test Step 1. CHECK THE SOLENOID, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the disconnect switch and the key start switch to the OFF position.
C. Disconnect the machine harness connector from the Swing Brake solenoid.
D. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• YES - The CID 0374 FMI 06 diagnostic code remains active. Disconnecting the solenoid did
not change the code. The solenoid is NOT the cause of the problem.
Repair: The machine harness has failed, or the ECM may have failed.
Go to Test Step 2.
• NO - The CID 0374 FMI 06 diagnostic code is no longer active, and has been replaced by an
active CID 0374 FMI 05 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness connections, are correct. The solenoid has failed.Perform
Test Step 1 again, to verify the solenoid failure. Replace the solenoid.
Go to Test Step 3
Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. The harness connector remains disconnected from the Swing Brake solenoid.
D. Disconnect the J1 and the J2 machine harness connectors from the Machine ECM.
E. At the ECM J2 harness connector, measure the resistance from contact J2-23 (K907-BU of
K906-GN) to all of the other contacts of the ECM harness connectors.
Expected Result:
Results:
• YES - Each resistance is more than 5000 ohms. The harness is correct. Go to Test Step 3.
• NO - Each resistance is NOT more than 5000 ohms. There is a short in the harness. The short is
between J2-23 (K907-BU or K906-GN) and the circuit with the low resistance measurement.
Go to Test Step 3.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
B. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are fastened securely.
D. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0374 FMI 06 diagnostic code is not active. The code does not exist at this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
• NO - The CID 0374 FMI 06 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Cat® Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem has NOT been found, and the original code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:31:07 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05264022
(Engine Cooling Fan Speed Sensor - Abnormal Frequency, Pulse Width, or Period)
Illustration 1 g02025271
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is recorded when the ECM receives intermittent signals from the engine cooling
fan speed sensor (CID 0544) while the engine is running. An FMI 08 diagnostic code indicates the
machine ECM has determined the sensor output signal voltage has an abnormal frequency, pulse
width, or period.
This Hall-effect type fan speed sensor is mounted near the center of the viscous fan drive clutch. The
fan speed sensor is not separately serviceable from the fan drive clutch assembly.
The ECM fan speed map uses actual fan speed, coolant temperature, and engine rpm inputs to
determine the targeted fan speed. For more information, refer to Special Instruction, REHS4721,
"Operation, Troubleshooting and Testing of the Viscous Coupling".
• Failed sensor
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that the 544-8 diagnostic code is still
active, before performing the following procedures.
Note: Check for other related diagnostic codes before performing the following diagnostic code
procedure. If a 248-12 diagnostic code for the data link exists, correct the data link problem. Then
view the status of the other diagnostic codes and correct the other active codes.
System Response:
If a fan speed signal is not supplied to the machine ECM, the fan will default to maximum fan speed.
A. Turn the key start switch and the disconnect switch to the OFF position.
Note: The engine cooling fan speed sensor circuit wires are routed through the viscous fan
drive clutch harness connector.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
C. In the harness connector for the Viscus Clutch, place a jumper wire between the contact for
terminal 1 (wire G834-PU) and the contact for terminal 2 (wire A209-BK) in the Viscus Clutch
harness connector.
D. Disconnect both the J1 and J2 harness connector from the machine ECM.
E. At the ECM harness connectors, measure resistance between contact J1-18 (wire A209-BK)
and contact J2-24 (wire G834-PU) in the ECM harness connectors.
Expected Result:
Results:
• NO - The resistance is not less than 5 ohms. There is an open circuit in the harness.
Go to Test Step 3.
A. The disconnect switch and the key start switch remain in the OFF position.
B. The Viscus Clutch, and both ECM harness connectors, remain disconnected.
C. Remove the jumper wire from the Viscus Clutch harness connector.
D. At the J2 ECM harness connector, measure resistance from contact J2-24 (wire G834-PU) to all
the other contacts used in both the J1 and J2 ECM harness connectors.
Expected Result:
Results:
• YES - All measurements are more than 5000 ohms. Go to Test Step 3.
• NO - All measurements are not more than 5000 ohms. There is a short circuit in the harness.
Go to Test Step 3.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The 544-8 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The 544-8 diagnostic code is still active. The problem has not been corrected. The fan
speed sensor, viscous clutch, or machine ECM, may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing. Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit. Perform a "wiggle test" on the sensor
circuit of the machine wiring harness, using the Caterpillar Electronic Technician service tool.
The "wiggle test" can be used to detect open or shorted connections in the machine wiring
harness. Refer to Testing and Adjusting, "Electrical Connector - Inspect " in this
manual.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem was not found, and the original code is still active, the fan speed sensor, viscous
clutch, or machine ECM, may have failed. Is highly recommended that you replace the Fan
Drive Assembly first, and then perform Test Step 3 again. Refer to Special Instruction,
REHS4721, "Operation, Troubleshooting and Testing of the Viscous Coupling". Prior to
replacing an ECM, always contact your Dealership Technical Communicator for possible
consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM
needs to be replaced, see Testing and Adjusting, "Electronic Control Module (ECM) -
Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:31:21 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04165709
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 1 g02357696
This diagnostic code is for the Power Shift Pressure solenoid. An FMI 03 diagnostic code indicates
the machine ECM has determined the solenoid circuit voltage is above the normal limit.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all the machine harnesses and connectors involved in the circuit. Make
sure to verify that all of the connections in the circuit are clean, secure, and in good condition.
Correct any problems found with any of the connections. Verify the diagnostic code CID 0581
FMI 03 is still active, before continuing with this procedure.
Note: The following test procedure may create other diagnostic codes. Ignore all the created
diagnostic codes now, but clear all those codes after the cause for the original diagnostic code has
been corrected.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness from the Power Shift Pressure solenoid.
C. Disconnect both the J1 and J2 harness connectors from the machine ECM.
D. At J2 ECM harness connector, measure resistance from contact J2-4 (wire L969-WH) to all the
other contacts used in both the J1 and J2 ECM Harness connectors.
Expected Result:
Results:
• NO - Each resistance is not greater than 5000 ohms. There is a short circuit in the machine
harness.
Go to Test Step 2.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 0581 FMI 03 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
• NO - The CID 0581 FMI 03 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 2 again. If the
problem is not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, contact your Dealership Technical Communicator for
consultation with Caterpillar, or the Dealer Solutions Network. This consultation may greatly
reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting, "Electronic
Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:31:54 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04161820
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Illustration 1 g02357696
This diagnostic code is for the Power Shift Pressure solenoid. An FMI 05 diagnostic code indicates
the machine ECM has determined the solenoid circuit current is below normal.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all the machine harnesses and connectors involved in the circuit. Make
sure to verify that all of the connections in the circuit are clean, secure, and in good condition.
Correct any problems found with any of the connections. Verify the diagnostic code CID 0581
FMI 05 is still active, before continuing with this procedure.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
Note: The following test procedure may create other diagnostic codes. Ignore all the created
diagnostic codes now, but clear all those codes after the cause for the original diagnostic code has
been corrected.
Table 1
Switch State Switch Contacts Status
Active Contacts 5 & 6 and 11 & 12 Closed
Active Contacts 5 & 4 and 11 & 10 Open
Inactive Contacts 5 & 6 and 11 & 12 Open
Inactive Contacts 5 & 4 and 11 & 10 Closed
A. Turn the starter keyswitch and the disconnect switch to the OFF position.
C. Toggle the switch from one state to the other. On each of the switch two states, check for
continuity on the switch pins listed on Table 1.
Expected Result:
Results:
• NO - The switch continuity is not correct. The Backup Switch has failed.
Go to Test Step 4.
A. The disconnect switch and the starter keyswitch remain in the the OFF position.
C. Disconnect the machine harness from the Power Shift Pressure solenoid.
D. In the machine harness connector for the solenoid, place a jumper wire from the contact for
terminal 1 (wire A768-BU) to the contact for terminal 2 (wire A769-GY) in the solenoid
harness connector.
E. Turn the starter keyswitch and the disconnect switch to the ON position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
Expected Result:
Results:
• YES - The diagnostic code is active. The solenoid is not the problem. Go to Test Step 3.
• NO - The CID 0581 FMI 05 diagnostic code is not active and has been replaced by an active
CID 0581 FMI 05 diagnostic code. The solenoid has failed.
Go to Test Step 4.
A. Turn the starter keyswitch and the disconnect switch to the OFF position.
E. At the J2 harness connector, measure resistance from contact J2-4 (wire L969-WH) to J2-20
(wire L968-OR) in the J2 ECM harness connector.
Expected Result:
Results:
• NO - The resistance is more than 5 ohms. There is an open circuit in the machine harness.
Go to Test Step 4.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
Expected Result:
Results:
• YES - The CID 0581 FMI 05 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 0581 FMI 05 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 4 again. If the
problem is not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, contact your Dealership Technical Communicator for
consultation with Caterpillar, or the Dealer Solutions Network. This consultation may greatly
reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting, "Electronic
Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:32:08 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04161821
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Illustration 1 g02357696
This diagnostic code is for the Power Shift Pressure solenoid. An FMI 06 indicates the machine ECM
has determined that the solenoid circuit current is above normal.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all the machine harnesses and connectors involved in the circuit. Make
sure to verify that all of the connections in the circuit are clean, secure, and in good condition.
Correct any problems found with any of the connections. Verify the diagnostic code CID 0581
FMI 06 is still active, before continuing with this procedure.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
Note: The following test procedure may create other diagnostic codes. Ignore all the created
diagnostic codes now, but clear all those codes after the cause for the original diagnostic code has
been corrected.
Table 1
Switch State Switch Contacts Status
Active Contacts 5 & 6 and 11 & 12 Closed
Active Contacts 5 & 4 and 11 & 10 Open
Inactive Contacts 5 & 6 and 11 & 12 Open
Inactive Contacts 5 & 4 and 11 & 10 Closed
A. Turn the key start switch and the disconnect switch to the OFF position.
C. Toggle the switch from one state to the other. On each of the switch two states, check for
continuity on the switch pins listed on Table 1.
Expected Result:
Results:
• NO - The switch continuity is not correct. The Backup Switch has failed.
Go to Test Step 4.
A. The disconnect switch and the starter keyswitch remain in the OFF position.
C. Disconnect the machine harness from the Power Shift Pressure solenoid.
D. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
Results:
• YES - The diagnostic code is still active. The solenoid is not causing the problem. Go to Test
Step 3.
• NO - The CID 0581 FMI 06 diagnostic code is not active and has been replaced by an active
CID 0581 FMI 05 diagnostic code. The solenoid has failed.
Go to Test Step 4.
A. Turn the key start switch and the disconnect switch to the OFF position.
C. Disconnect both the J1 and J2 harness connector from the machine ECM.
D. At the J2 machine harness connector, measure for resistance from contact J2-4 (wire L969-
WH) to all possible sources of ground in both the J1 and J2 ECM harness connectors.
Expected Result:
Results:
• YES - Each resistance measurement is more than 5000 ohms. Go to Test Step 4.
• NO - Each resistance measurement is not more than 5000 ohms. There is a short circuit in the
machine harness.
Go to Test Step 4.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
Results:
• YES - The CID 0581 FMI 06 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 0581 FMI 06 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 4 again. If the
problem was again not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:32:22 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05428865
Illustration 1 g03426166
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is associated with the "engine speed dial" switch. The FMI 05 diagnostic code
means that the ECM has determined that the current of the switch is below normal.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0586 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the OFF position. Do not start the engine.
B. Disconnect the "engine speed dial" switch from the machine harness.
C. Use the following table for the position of the rotary dial and check the corresponding
resistance for the switch.
Table 1
Rotary Dial Position Check the Resistance Between the Following Contacts on the
Switch.
Contact (1)
1 to
Contact (2)
Contact (1)
3 to
Contact (3)
Contact (1)
7 to
Contact (4)
Contact (1)
10 to
Contact (5)
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
• OK - The resistance is less than 5 ohms. The switch is correct. Proceed to Test Step 2.
• NOT OK - The resistance is greater than 5 ohms. The resistance measurement is not correct.
There is an open circuit in the switch.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. Use the following table for the placement of a jumper wire to the connector for the switch.
Check the corresponding resistance for the contacts of the machine harness connectors.
Table 2
Jumper Location on the
Connections on the Machine Harness
Connector for the Switch
Contact (1)
Contact J1-10 (wire A755-PK) and contact J1-2 or J1-14
to
(wire 235-BK) of the machine harness.
Contact (2)
Contact (1)
Contact J1-19 (wire A756-BU) and contact J1-2 or J1-14
to
(wire 235-BK) of the machine harness.
Contact (3)
Contact (1)
Contact J1-20 (wire A757-GY) and contact J1-2 or J1-
to
14 (wire 235-BK) of the machine harness.
Contact (4)
Contact (1)
Contact J1-11 (wire A758-BR) and contact J1-2 or J1-14
to
(wire 235-BK) of the machine harness.
Contact (5)
Expected Result:
Results:
• OK - The resistance is less than 5 ohms. The machine harness is correct. Proceed to Test Step
3.
• NOT OK - The resistance is greater than 5 ohms. The resistance measurement is not correct.
There is an open circuit in the machine harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0586 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: A failure of the Machine ECM is unlikely. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0586 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection at one
of the harness connectors that was disconnected and reconnected. Resume normal machine
operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:32:44 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05428871
Illustration 1 g03426166
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
This diagnostic code is recorded when the ECM cannot communicate with the Engine Speed Dial
switch.
• The Machine ECM may have failed, but this situation is unlikely.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the Engine Speed Dial switch from the machine harness.
C. Use Table 1 to check resistance on the rotary switch for each position listed on the table.
Table 1
Rotary Dial Position Check the Resistance Between the Following Contacts on the
Switch.
1 Contact (1) to Contact (2)
3 Contact (1) to Contact (3)
7 Contact (1) to Contact (4)
10 Contact (1) to Contact (5)
Expected Result:
Results:
• OK - Each resistance measurement is less than 5 ohms. The switch is correct. Proceed to Test
Step 3.
STOP
A. The disconnect switch and the key start switch remain in the OFF position.
B. Inspect the harness connections. Make sure that the connectors are clean and that the
connectors are tight.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
Expected Result:
Results:
• OK - The machine harness connectors are tight and free of corrosion. Proceed to Test Step 4.
• NOT OK - The machine harness connectors are NOT tight or NOT free of corrosion.
STOP
A. The disconnect switch and the key start switch remain in the OFF position.
B. Disconnect the J1 and J2 machine harness connectors from the Machine ECM.
C. Use the following table for the placement of a jumper wire to the connector for the switch.
Check the corresponding resistance for the contacts of the machine harness connectors.
Table 2
Jumper Location on the
Connectors on the Machine Harness
Connector for the Switch
Contact (1)
Contact J1-10 (wire A755-PK) and contact J1-2 or J1-14
to
(wire 235-BK) of the machine harness.
Contact (2)
Contact (1)
Contact J1-19 (wire A756-BU) and contact J1-2 or J1-
to
14 (wire 235-BK) of the machine harness.
Contact (3)
Contact (1)
Contact J1-20 (wire A757-GY) and contact J1-2 or J1-
to
14 (wire 235-BK) of the machine harness.
Contact (4)
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
Contact (1)
Contact J1-11 (wire A758-BR) and contact J1-2 or J1-14
to
(wire 235-BK) of the machine harness.
Contact (5)
Expected Result:
Results:
• OK - The resistance measurements are all less than 5 ohms. The machine harness is correct.
Proceed to Test Step 4.
STOP
A. The disconnect switch and the key start switch remain in the OFF position.
B. The ECM and the Engine Speed Dial switch remain disconnected from the machine harness.
C. At the machine harness connector for the ECM, measure the resistance between frame ground
and the following connector contacts: J1-10 (wire A755-PK), J1-19 (wire A756-BU), J1-20
(wire A757-GY) and J1-11 (wire A758-BR).
Expected Result:
Results:
• OK - The resistance measurements are all greater than 5000 ohms. The resistance of the
circuits is correct. Proceed to Test Step 5.
• NOT OK - A resistance measurement is less than 5000 ohms. The resistance of the circuit is
not correct.
Repair: There is a short between the frame ground and the circuits that measured less than
5000 ohms in the machine harness. Replace, or repair, the machine harness.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• OK - The diagnostic code of CID 0586 FMI 12 is not active. The code does not exist at this
time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal machine operations.
STOP
• NO - The CID 0586 FMI 12 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Cat® Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem has NOT been found, and this diagnostic code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:32:59 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 6
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05428894
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 6
Illustration 1 g03426211
This diagnostic code is caused by abnormal communications between the Machine ECM and the
Monitor Display module through the Data Link. The update rate is not correct. Check for diagnostic
codes that are related to the data link circuits. Check in the "Machine ECM" and in the Monitor
Display module. If diagnostic codes are present, correct the related diagnostic codes first.
For machines equipped with the E-Fence feature, reference Troubleshooting, "E-Ceiling and
Cab Avoidance - Troubleshoot"
A possible cause of this diagnostic code is that the Machine ECM is operating intermittently.
The Data Link is an input and output of all electronic control modules. The Data Link is designed to
carry communications between the electronic control modules. The Data Link is not a visible
component. The Data Link consists of internal control circuits and the connecting harness wiring
between the components.
System Response:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 6
This failure results in events that are logged against a Machine ECM that cannot be explained
directly. The Machine ECM cannot communicate with the Monitor Display module or the Machine
ECM appears to communicate intermittently with the Monitor Display module.
Test Step 1. VERIFY THE HARDWARE AND THE SOFTWARE PART NUMBERS.
◦ The part number of the flash software for the Machine ECM.
◦ The part number of the flash software for the Monitor Display ECM.
Note: Consult your Caterpillar Dealer for the correct part numbers of the flash software.
Expected Result:
Results:
Repair: The installed Machine ECM or the Monitor Display ECM have the wrong part number
or the incorrect flash software is installed. Replace the incorrect Machine ECM or the Monitor
Display ECM with a module that has the correct part number. Flash the correct software. See
the Testing and Adjusting, "Electronic Control Module (ECM) - Flash Program" section for
additional information.
STOP
B. Inspect all harness connections that are related to the Cat Data Link. Make sure that the
connectors are clean and tight.
C. Check the connectors for proper mating. Ensure that all the seals are present and in place.
E. Check the wires at the connector. Ensure that the wires are secured tightly into the connector.
Take care not to pull the wire out of the connector.
F. Check the exposed wires at the connectors for nicks or signs of abrasion.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 6
I. Check each pin and each socket of the machine harness connectors. Ensure that the contacts are
properly installed. The contacts should mate correctly when the two pieces of the connector are
placed together.
Expected Result:
Results:
• OK - The machine harness connectors are tight and free of corrosion. Proceed to Test Step 3.
STOP
B. Disconnect the machine harness connectors from all electronic control modules that use the Cat
Data Link.
C. At the machine harness for the Machine ECM, measure the resistance between frame ground
and connector contacts J1-33 (wire 893-GN) and J1-43 (wire 892-BR) of the Cat Data Link
circuit.
Expected Result:
Results:
• OK - The resistance is greater than 5000 ohms. The harness circuit resistance is correct.
Proceed to Test Step 4.
• NOT OK - The resistance is less than 5000 ohms. The machine harness has failed.
Repair: There is a short between frame ground and contacts J1-33 (wire 893-GN) and J1-43
(wire 892-BR) of the Cat Data Link circuit in the machine harness. Repair the machine harness
or replace the machine harness.
STOP
B. All related electronic control modules remain disconnected from the machine harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 6
C. At the machine harness connector for the Machine ECM, perform the checks that are listed
here:
◦ Measure the resistance between the connector contact J1-1 (wire 184-RD) and connector
contact J1-33 (wire 893-GN).
◦ Measure the resistance between connector contact J1-1 (wire 184-RD) and connector
contact J1-43 (wire 892-BR).
Expected Result:
Results:
• NOT OK - The resistance is less than 5000 ohms. The machine harness has failed.
Repair: There is a short between the +battery circuit and contacts J1-33 (wire 893-GN) and J1-
43 (wire 892-BR) of the Cat Data Link circuit in the machine harness. Repair the machine
harness or replace the machine harness.
STOP
B. All related electronic control modules remain disconnected from the machine harness.
C. Check the resistance of the Cat® Data Link circuit in the machine harness:
◦ Measure the resistance between connector contact J1-33 (wire 893-GN) of the Machine
ECM and connector contact 7 (wire 893-GN) of the Monitor Display ECM.
◦ Measure the resistance between connector contact 43 (wire 892-BR) of the Machine
ECM and connector contact 8 (wire 892-BR) of the Monitor Display ECM.
Expected Result:
Results:
• OK - The resistance is less than 5 ohms. The Cat Data Link circuit in the machine harness is
correct. Proceed to Test Step 6.
• NOT OK - The resistance is greater than 5 ohms. The machine harness has failed.
Repair: The Cat Data Link circuit is open in the machine harness. Repair the machine harness
or replace the machine harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 6
STOP
Test Step 6. CHECK FOR ADDITIONAL DIAGNOSTIC CODES FOR THE OTHER
ELECTRONIC CONTROL MODULES.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. One at a time, reconnect the electronic control modules that use the Cat Data Link.
C. Turn the disconnect switch and the key start switch to the ON position after reconnecting each
module.
D. After each of the electronic control modules has been reconnected, check for diagnostic codes
that are logged against that electronic control module.
Make sure to turn the key start switch and the disconnect switch to the OFF position
before each control module is reconnected.
Expected Result:
Diagnostic codes are not present for the other electronic control modules.
Results:
• OK - Diagnostic codes are not present for the other electronic control modules. The Monitor
Display module has failed.
Repair: Is unlikely that the Monitor Display module has failed. Exit this procedure and
perform this procedure again. If the failure is not found, replace the Monitor Display module.
STOP
• NOT OK - Diagnostic codes are present for the other electronic control modules. The
"Machine ECM" has failed.
Repair: A failure of the "Machine ECM" is unlikely. Exit this procedure. Perform this
procedure again. If the failure is not found, contact your Dealership Technical Communicator
for possible consultation with Caterpillar. If the "Machine ECM" needs to be replaced,
reference Testing and Adjusting, "Electronic Control Module (ECM) - Replace" section.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:33:14 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755740
Illustration 1 g02025733
This diagnostic code is recorded when the Machine ECM does not receive expected information from
the Engine ECM. The possible causes of this diagnostic code are listed below:
• The wires for the Cat Data Link to the Engine ECM are open or the wires are shorted.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Test Step 1. VERIFY THE HARDWARE AND THE SOFTWARE PART NUMBERS.
◦ The part number of the flash software for the Engine ECM
◦ The part number of the flash software for the Machine ECM
Note: Consult your Caterpillar Dealer for the correct part numbers of the flash software.
Expected Result:
Results:
Repair: The installed Engine ECM or the Machine ECM have the wrong part number or the
incorrect flash software is installed. Replace the Engine ECM or replace the Machine ECM that
is incorrect. Replace the ECM with a module that has the correct part number. Flash the correct
software. See Testing and Adjusting, "Electronic Control Module (ECM) - Flash Program" for
additional information.
STOP
B. Inspect all harness connections that are related to the Cat Data Link. Make sure that the
connectors are clean and tight.
C. Check the connectors for proper mating. Ensure that all the seals are present and in place.
E. Check the wires at the connector. Ensure that the wires are secured tightly into the connector.
Take care not to pull the wire out of the connector.
F. Check the exposed wires at the connectors for nicks or signs of abrasion.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
I. Check each pin and each socket of the machine harness connectors. Ensure that the contacts are
properly installed. The contacts should mate correctly when the two pieces of the connector are
placed together.
Expected Result:
Results:
• OK - The machine harness connectors are tight and free of corrosion. Proceed to Test Step 3.
STOP
B. Disconnect the machine harness connectors from all electronic control modules that use the Cat
Data Link.
C. At the machine harness connector for the Machine ECM, measure the resistance between
connector contact J1-33 (wire 893-GN) and all of the contacts that are used in the machine
harness connector for the ECM. Perform the same measurements for J1-43 (wire 892-BR).
Expected Result:
Results:
• OK - Each of the resistance measurements is greater than 5000 ohms. The harness circuit
resistance is correct. Proceed to Test Step 4.
• NOT OK - One of the resistance measurements is less than 5000 ohms. The machine harness
has failed.
Repair: There is a short between contacts J1-33 (wire 893-GN) or J1-43 (wire 892-BR) of the
Cat Data Link and the circuit with the low resistance measurement. Repair the machine harness
or replace the machine harness.
STOP
B. All related electronic control modules remain disconnected from the machine harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
C. Check the resistance of the Cat Data Link circuit in the machine harness:
◦ Measure the resistance between connector contact J1-23 (wire 893-GN) of the Engine
ECM and connector contact J1-33 (wire 893-GN) of the Machine ECM.
◦ Measure the resistance between connector contact J1-24 (wire 892-BR) of the Engine
ECM and connector contact J1-43 (wire 892-BR) of the Machine ECM.
Expected Result:
Results:
• OK - The resistance is less than 5 ohms. The Cat Data Link circuit in the machine harness is
correct. Proceed to Test Step 5.
• NOT OK - The resistance is greater than 5 ohms. The machine harness has failed.
Repair: The Cat Data Link circuit is open in the machine harness. Repair the machine harness
or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the contacts.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0590 FMI 09 diagnostic code is active. The diagnostic code has not been
corrected. The Machine ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0590 FMI 09 diagnostic code is not active. The diagnostic code does not exist at
this time.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:33:31 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755872
Illustration 1 g02025837
This diagnostic code is associated with the "Travel Speed Solenoid" valve. The FMI 03 diagnostic
code means that the Machine ECM has determined that the voltage of the solenoid circuit is above
normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0598 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
THE +BATTERY CIRCUIT.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-3 (wire
763-BU) to all contacts that are used in the machine harness connectors for the Machine ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-3 (763-BU) and the circuit that has a low resistance
measurement.
STOP
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
• YES - The CID 0598 FMI 03 diagnostic code is active. The problem has not been corrected.
The Machine ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0598 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:33:48 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755892
Illustration 1 g02025837
This diagnostic code is associated with the "Travel Speed Solenoid" valve. The FMI 05 diagnostic
code means that the Machine ECM has determined that the current of the solenoid is below normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0598 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
763-BU) to contact 2 (wire 235-BK).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous Test Step remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-3 (wire 763-
BU) to ground (wire 235-BK).
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step
3.
• NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire 763-BU or in wire 235-BK of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors. Clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0598 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0598 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:34:04 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755896
Illustration 1 g02025837
This diagnostic code is associated with the "Travel Speed Solenoid" valve. The FMI 06 diagnostic
code means that the ECM has determined that the current of the solenoid is above normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0598 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 0598 FMI 06 diagnostic code changes to a CID 0598 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 0598 FMI 06 diagnostic code changes to a CID 0598 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 0598 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-3 (wire
763-BU) to all contacts that are used in the machine harness connectors for the ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-3 (wire 763-BU) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0598 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0598 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:34:30 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434373
Illustration 1 g02025857
This diagnostic code is associated with the Hydraulic Oil Temperature sensor. An FMI 04 diagnostic
code means that the Monitor ECM has determined the voltage of the sensor is below normal. The
ECM records this diagnostic code from information received from the Monitoring System through the
Cat® Data Link.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
System Response:
Diagnostic code CID 0600 FMI 04 will be logged in the internal memory of the Machine ECM.
A. Turn the engine OFF. Turn the disconnect switch and the key start switch to the OFF position.
C. Turn the disconnect switch and the key start switch to the ON position. Turn the engine back
ON.
Expected Result:
Results:
• YES - The CID 0600 FMI 04 diagnostic code is no longer active. The sensor has failed.
STOP
• NO - The CID 0600 FMI 04 diagnostic code remains active. The sensor is not the cause of the
code. Proceed to Test Step 2.
B. Turn the engine OFF. Turn the disconnect switch and the key start switch to the OFF position.
C. At the machine harness connector for the sensor, measure the resistance between the sensor
output signal, contact (wire 491-PK), and frame ground.
Expected Result:
Results:
• OK - The resistance is greater than 5000 ohms. The harness circuit resistance is correct.
Repair: A failure of the Monitor ECM is unlikely.Perform Test Step 2 again. If the problem
has NOT been found, and the diagnostic code is still active, the Monitor ECM may have
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. If the Monitor
ECM needs to be replaced, see Testing and Adjusting , "Electronic Control Module (ECM) -
Replace".
STOP
• NOT OK - The resistance is less than 5000 ohms. The machine harness has failed. There is a
short between frame ground and the sensor output signal circuit in the machine harness.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:34:46 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03755921
Illustration 1 g02025874
This diagnostic code is associated with the "Heavy Lift Solenoid" valve. The FMI 03 diagnostic code
means that the Machine ECM has determined that the voltage of the solenoid circuit is above normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0735 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
THE +BATTERY CIRCUIT.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-31
(wire G723-YL) to all contacts that are used in the machine harness connectors for the ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-31 (G723-YL) and the circuit that has a low
resistance measurement.
STOP
A. Inspect the contacts of the harness connector. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
• YES - The CID 0735 FMI 03 diagnostic code is active. The problem has not been corrected.
The ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the Machine ECM.
See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0735 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:35:06 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756021
Illustration 1 g02025874
This diagnostic code is associated with the "Heavy Lift Solenoid" valve. The FMI 05 diagnostic code
means that the ECM has determined that the current of the solenoid is below normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0735 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
G723-YL) to contact 2 (wire 235-BK).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous Test Step remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-31 (wire G723
-YL) to ground (wire 235-BK).
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step
3.
• NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire G723-YL or in wire 235-BK of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0735 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0735 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:35:26 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756028
Illustration 1 g02025874
This diagnostic code is associated with the "Heavy Lift Solenoid" valve. The FMI 06 diagnostic code
means that the ECM has determined that the current of the solenoid is above normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 0735 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 0735 FMI 06 diagnostic code changes to a CID 0735 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 0735 FMI 06 diagnostic code changes to a CID 0735 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 0735 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-31 (wire
G723-YL) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-31 (wire G723-YL) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 0735 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 0735 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:36:13 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04162072
Illustration 1 g02025913
This diagnostic code is for the right side Auxiliary Pedal position sensor. An FMI 03 diagnostic code
means the machine ECM has determined the sensor output signal voltage is above the normal limit.
• Failed sensor.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1129 FMI 03 is
still active, before performing the following procedures.
A. Turn the disconnect switch and the key start switch to the "ON" position.
C. At the machine harness connector for the right side Auxiliary Pedal position sensor, measure
the voltage between the contact for terminal 1 (wire E472-GN) and contact 2 (wire 235-BK) on
the sensor connector.
Expected Result:
Results:
• YES - The voltage is 8.0 ± 0.5 DCV. The power supply is not the problem. Go to Test Step 2.
• NO - The voltage is not 8.0 ± 0.5 DCV. There is a problem with the +8 DCV power supply.
Repair: Refer to the complete electrical schematics for the machine. Investigate the ECM +8
DCV power supply problem.
After +8 DCV power supply problem is repaired, check if the 1129 FMI 03 diagnostic code is
still active. If the diagnostic code is still active, go to Test Step 2.
Test Step 2. CHECK THE SENSOR, THE ECM, AND THE MACHINE HARNESS.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the right side Auxiliary Pedal position sensor.
C. In the harness connector for the sensor, place a jumper wire between the contact for terminal 3
(wire N795-WH) and the contact for terminal 2 (wire 235-BK) in the sensor connector.
D. Turn the key start switch and the disconnect switch to the ON position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
Expected Result:
Results:
• YES - The CID 1129 FMI 03 diagnostic code remains active. The sensor is not causing the
problem. Go to Test Step 3.
• NO - The CID 1129 FMI 03 diagnostic code is no longer active. The diagnostic code has been
replaced by an active CID 1129 with a different FMI code. The sensor has failed.
Go to Test Step 5.
A. Turn the disconnect switch and the key start switch to the OFF position.
D. Disconnect both the J1 and J2 harness connector from the machine ECM.
E. At the ECM J1 harness connector, measure the resistance between contact J1-54 (N795-WH)
and contact J1-2 (235-BK) in the J1 harness connector.
Note: A Right Side Auxiliary Pedal sensor Ground Return is also found at contact J1-14
(235-BK). Always check these parallel ground wires. Make sure to repair or replace any
that are found open.
Expected Result:
Results:
• NO - The resistance is not less than 5 ohms. There is an open circuit in the machine harness.
Go to Test Step 5.
A. The disconnect switch and the key start switch remain in the OFF position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
D. Measure resistance from contact J1-54 (wire N795-WH) to all the other contacts used in both
the J1 and the J2 ECM harness connectors.
Expected Result:
Results:
• YES - All measurements are more than 5000 ohms. Go to Test Step 5.
• NO - All measurements are not more than 5000 ohms. There is a short circuit in the machine
harness.
Go to Test Step 5.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 1129 FMI 03 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 1129 FMI 03 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 5 again. If the
problem was again not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:36:27 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756088
Illustration 1 g02025913
This diagnostic code is associated with the sensor for the "Right Side Auxiliary" pedal. The FMI 04
diagnostic code means that the Machine ECM has determined that the voltage of the circuit for the
position sensor is below normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1129 FMI 04 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
A. Turn the disconnect switch and the key start switch to the ON position.
C. Observe the status of the diagnostic code. Disconnect the sensor from the machine harness.
Expected Result:
Results:
• OK - The diagnostic code remains active. The sensor is correct. Proceed to Test Step 2.
• NOT OK - The diagnostic code is no longer active. The sensor has failed.
STOP
Test Step 2. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO
GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector for the Machine ECM, measure the resistance from the signal
contact J1-54 (wire N795-WH) of the machine harness to all possible sources of ground.
Measure the resistance to all contacts of the machine harness connectors for the ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
• NOT OK - One or more resistance measurements is not correct. There is a short in the machine
harness.
Repair: The short is between signal contact J1-54 (wire N795-WH) and the circuit with the
low resistance measurement. Repair the machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1129 FMI 04 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1129 FMI 04 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:36:39 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04170111
Illustration 1 g02025913
This diagnostic code is for the right side Auxiliary Pedal position sensor. An FMI 08 diagnostic code
means the machine ECM has determined the sensor output signal has an abnormal frequency, pulse
width, or period.
• Failed sensor.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1129 FMI 08 is
still active, before performing the following procedures.
System Response:
Test Step 1. CHECK THE SENSOR, THE ECM, AND THE MACHINE HARNESS.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the right side Auxiliary Pedal position sensor.
C. In the harness connector for the sensor, place a jumper wire between the contact for terminal 3
(wire N795-WH) and the contact for terminal 2 (wire 235-BK) in the sensor connector.
D. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 1129 FMI 08 diagnostic code remains active. The sensor is not causing the
problem. Go to Test Step 2.
• NO - The CID 1129 FMI 08 diagnostic code is no longer active. The diagnostic code has been
replaced by an active CID 1129 with a different FMI code. The sensor has failed.
Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. Disconnect both the J1 and J1 harness connectors from the machine ECM.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
E. At the ECM J1 harness connector, measure the resistance between contact J1-54 (wire N795-
WH) and frame ground.
F. Again at the ECM J1 harness connector, measure the resistance between contact J1-54 (wire
N795-WH) and all of the other contacts that are used in both the J1 and J2 ECM harness
connectors.
Expected Result:
Results:
• YES - All resistance readings are greater than 5000 ohms. Go to Test Step 3.
• NO - All resistance readings are not greater than 5000 ohms. There is a short circuit in the
machine harness.
Go to Test Step 3.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 1129 FMI 08 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 1129 FMI 08 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem was again not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:36:58 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 5
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434448
Illustration 1 g02157109
This diagnostic code is associated with the Left Side Auxiliary pedal sensor. An FMI 03 diagnostic
code means the Machine ECM has determined the signal output voltage of the sensor is above
normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 5
• The Machine ECM may have failed, but this situation is unlikely.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1130 FMI 03 is
still active, before performing the following procedures.
A. Turn the key start switch and the disconnect switch to the ON position. Do not start the engine.
C. At the back of the harness connector for the Left Side Auxiliary pedal sensor: insert the 7X-
1710 Multimeter Probes along contact 1 (E472-GN), the sensor contact for the +8 VDC supply,
and contact 2 (235-BK), the sensor ground return.
Expected Result:
Results:
• YES - The voltage measurement is 8 ± 0.5 VDC. The power supply is correct. Go to Test Step
2.
• NO - The voltage is NOT 8 VDC. The 8 VDC power supply in the machine ECM has failed, or
the machine harness has failed. Go to Test Step 3
Test Step 2. CHECK THE SENSOR, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the Left Side Auxiliary pedal sensor.
C. At the harness connector for the Left Side Auxiliary pedal sensor, place a jumper wire between
contact 3 (N794-GY) and contact 2 (235-BK) on the connector.
D. Turn the key start switch and the disconnect switch to the ON position. Do not start the engine.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 5
Expected Result:
Results:
• YES - The CID 1130 FMI 03 diagnostic code remains active. The jumper wire did not change
the code. The sensor is NOT the cause of the problem.
Repair: The machine harness has failed, or the ECM may have failed.
Go to Test Step 3.
• NO - The CID 1130 FMI 03 diagnostic code is no longer active, and has been replaced by an
active CID 1130 FMI 04 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness, are correct. The sensor has failed. Replace the sensor.
Go to Test Step 5
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the machine harness connector from the Left Side Auxiliary pedal sensor.
C. At the harness connector for the Left Side Auxiliary pedal sensor, place a jumper wire between
contact 3 (N794-GY) and contact 2 (235-BK) on the connector.
D. At the Machine ECM, disconnect the J1 and J2 machine harness connector from the ECM.
E. At the ECM J1 harness connector, measure the resistance between the pin for contact J1-53
(N794-GY) and the pin for contact J1-2 (235-BK) on the harness connector.
Note: A Left Side Auxiliary sensor Ground Return is also found at contact J1-14 (235-
BK). Always check these parallel ground wires. Make sure to repair or replace any that
are found open.
Expected Result:
Results:
• YES - The resistance is less than 5 ohms. The sensor output circuit is not open. Go to Test Step
4
• NO - The resistance is NOT less than 5 ohms. The sensor output signal is open.
Repair: The open is in wire N794-GY in the harness connector. Repair, or replace, the harness.
Go to Test Step 5.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 5
Test Step 4. CHECK THE SENSOR OUTPUT SIGNAL FOR A SHORT TO A VOLTAGE
SOURCE.
A. The disconnect switch and the key start switch remain in the OFF position.
C. The Left Side Auxiliary pedal sensor harness connector remains disconnected.
E. At the J1 harness connector for the ECM, measure the resistance between contact J1-53 (N794-
GY) and all of the other contacts used in the harness connectors for the ECM.
Expected Result:
Results:
• YES - Each resistance is more than 5000 ohms. The sensor output signal is NOT shorted to a
power supply. Proceed to Test Step 4.
• NO - One of the resistance measurements is NOT greater than 5000 ohms. There is a short in
the harness. The sort is between the sensor output signal wire and the wire with the low
resistance measurement.
B. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
C. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 5
• YES - The CID 1130 FMI 03 diagnostic code is no longer active. The code does not exist at
this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
• NO - The CID 1130 FMI 03 diagnostic code is still active. The problem has NOT been
corrected. The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Cat® Electronic Technician service tool. The "wiggle
test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 5 again. If the
problem has NOT been found, and the original code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting , "
Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:37:20 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03942796
Illustration 1 g02157109
This diagnostic code is associated with the Left Side Auxiliary pedal sensor. An FMI 04 diagnostic
code means the machine ECM has determined the signal output voltage of the sensor is below
normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1130 FMI 04 is
still active, before performing the following procedures.
Test Step 1. CHECK THE SENSOR, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the Left Side Auxiliary pedal sensor.
C. Turn the key start switch and the disconnect switch to the ON position. Do not start the engine.
Expected Result:
Results:
• YES - The CID 1130 FMI 03 diagnostic code remains active. Disconnecting the sensor did not
change the code. The sensor is NOT the cause of the problem.
Repair: The machine harness has failed, or the ECM may have failed.
Go to Test Step 2.
• NO - The CID 1130 FMI 04 diagnostic code is no longer active, and has been replaced by an
active CID 1130 FMI 03 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness, are correct. The sensor has failed. Replace the sensor.
Go to Test Step 3.
Test Step 2. CHECK THE SENSOR OUTPUT SIGNAL FOR A SHORT TO GROUND.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. At the machine ECM, disconnect the J1 and J2 machine harness connectors from the ECM.
C. The harness connector remains disconnected from the Left Side Auxiliary pedal sensor.
D. At the J1 harness connector for the ECM, measure the resistance between contact J1-53 (N794-
GY) and all of the other contacts used in the ECM harness connectors.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• YES - Each resistance is more than 5000 ohms. The sensor output signal circuit is not shorted
to ground. Go to Test Step 3.
• NO - One of the resistance measurements is NOT more than 5000 ohms. There is a short in the
harness. The short is between the sensor output signal wire and the wire with the low resistance.
Repair, or replace, the harness. Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1130 FMI 04 code is no longer active. The code does not exist at this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
• NO - The CID 1130 FMI 04 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Caterpillar Electronic Technician service tool.
The "wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are securely fastened. Perform Test Step 3 again. If
the problem has NOT been found, and this diagnostic code is still active, the ECM may have
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:37:39 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04170112
Illustration 1 g02025956
This diagnostic code is for the left side Auxiliary Pedal position sensor. An FMI 08 diagnostic code
means the machine ECM has determined the sensor output signal has an abnormal frequency, pulse
width, or period.
• Failed sensor.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1130 FMI 08 is
still active, before performing the following procedures.
System Response:
Test Step 1. CHECK THE SENSOR, THE ECM, AND THE MACHINE HARNESS.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the left side Auxiliary Pedal position sensor.
C. In the harness connector for the sensor, place a jumper wire between the contact for terminal 3
(wire N794-GY) and the contact for terminal 2 (wire 235-BK) in the sensor connector.
D. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 1130 FMI 08 diagnostic code remains active. The sensor is not causing the
problem. Go to Test Step 2.
• NO - The CID 1130 FMI 08 diagnostic code is no longer active. The diagnostic code has been
replaced by an active CID 1130 with a different FMI code. The sensor has failed.
Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. Disconnect both the J1 and J2 harness connectors from the machine ECM.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
E. At the ECM J1 harness connector, measure the resistance between contact J1-53 (wire N794-
GY) and frame ground.
F. Again at the ECM J1 harness connector, measure the resistance between contact J1-53 (wire
N794-GY) and all of the other pins that are used in both the J1 and J2 ECM harness connectors.
Expected Result:
Results:
• YES - All resistance readings are greater than 5000 ohms. Go to Test Step 3.
• NO - All resistance readings are not greater than 5000 ohms. There is a short circuit in the
machine harness.
Go to Test Step 3.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 1130 FMI 08 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 1130 FMI 08 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem was again not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:37:50 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756647
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 1 g02026198
This diagnostic code is associated with the "Hydraulic Lock" solenoid. The FMI 03 diagnostic code
means that the ECM has determined that the voltage of the solenoid circuit is above normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
When this diagnostic code occurs, a warning is displayed on the Monitoring System and the Machine
ECM disables the hydraulic system.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1160 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
The diagnostic code of CID 1160 FMI 03 will be logged in the internal memory of the Machine
ECM.
Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
THE +BATTERY CIRCUIT.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector J2 from the solenoid at the ECM.
C. Place a jumper between contacts 3 (wire A588-GN) and 5 (wire E564-PK) of the hydraulic lock
on relay.
D. At the machine harness connector for the ECM, measure the resistance from contact J2-27
(wire A588-GN) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-27 (A588-GN) and the circuit that has a low
resistance measurement.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
D. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1160 FMI 03 diagnostic code is active. The problem has not been corrected.
The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1160 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:38:08 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 6
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434522
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 6
Illustration 1 g02026198
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 6
When this diagnostic code occurs, a warning is displayed on the Monitoring System and the Machine
ECM disables the circuit.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear the diagnostic codes when the original diagnostic code is corrected.
A. Turn the key start switch and the disconnect switch to the OFF position.
C. At the machine harness connector of the solenoid, measure the resistance between contact 1
(wire A588-GN) and contact 2 (wire 200-BK).
Expected Result:
Results:
• OK - The resistance is between 25 and 39 ohms. The resistance is correct. The machine harness
or the hydraulic lock relay has failed. Proceed to Test Step 2.
• NOT OK - The resistance is NOT between 25 and 39 ohms. The resistance is not correct.
STOP
A. Turn the disconnect switch and the key start switch to the ON position.
C. At the machine harness connector for the solenoid, measure the voltage between contact 1 (wire
A588-GN) and contact 2 (wire 200-BK) while the hydraulic lock lever is moved from the
LOCKED position to the RELEASED position.
Expected Result:
The voltage measures 18 VDC to 28 VDC when the lever is in the RELEASED position. The voltage
measures approximately 0.0 ± 0.5 VDC in the LOCKED position.
Results:
• OK - The voltage measures 18 VDC to 28 VDC when the lever is in the RELEASED position.
The voltage measures approximately 0.0 ± 0.5 VDC in the LOCKED position. The voltage is
correct. Proceed to Test Step 3.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 6
• NOT OK - The voltage does not measure 18 VDC to 28 VDC when the lever is in the
RELEASED position. The voltage does not measure approximately 0.0 ± 0.5 VDC in the
LOCKED position. The voltage is not correct. The machine harness or the hydraulic lock relay
may have failed. Proceed to Test Step 4.
C. Turn the disconnect switch and the key start switch to the ON position.
D. Clear all active diagnostic codes from the Monitoring System by pressing the "OK" key on the
keypad.
F. Check the Monitoring System for an active diagnostic code. The diagnostic information may
also be viewed with the Cat® Electronic Technician.
Expected Result:
Results:
• OK - The diagnostic code for the solenoid is not present. The diagnostic code was probably
caused by a poor electrical connection or an open at one of the harness connectors that was
disconnected and reconnected. Resume normal machine operation.STOP
• NOT OK - The diagnostic code is still present. The Machine ECM has failed. A failure of the
Machine ECM is unlikely. Exit this test procedure and perform this procedure again.
Repair: If the cause of the diagnostic code is not found, replace the ECM. See Testing And
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Place a jumper between contacts 3 (wire A588-GN) and 5 (wire E564-PK) of the hydraulic lock
on relay.
C. Place a jumper between contacts 1 (wire A588-PK) and 2 (wire 200-BK) of the machine
harness connector for the solenoid.
D. Disconnect the machine harness connectors J1 and J2 from the Machine ECM.
E. At the machine harness connector J2, measure the resistance between contact J2-27 (wire A588
-GN) and frame ground.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 6
Expected Result:
Results:
• OK - The resistance measures less than 5 ohms. The resistance is correct. Proceed to Test Step
5.
• NOT OK - The resistance is greater than 5 ohms. The resistance is not correct. The machine
harness has failed.
STOP
B. Turn the disconnect switch and the key start switch to the ON position.
C. At the machine harness connector of the hydraulic lock on relay, measure the voltage between
contact 1 (wire E564-PK) and frame ground while the hydraulic lock lever is moved from the
LOCKED position to the RELEASED position.
Expected Result:
The voltage measures 18 VDC to 28 VDC when the lever is in the RELEASED position and the
voltage measures approximately 0.0 ± 0.5VDC in the LOCKED position.
Results:
• OK - The voltage measures 18 VDC to 28 VDC when the lever is in the RELEASED position
and the voltage measures approximately 0.0 ± 0.5 VDC in the LOCKED position. The voltage
is correct.
Repair: The relay has failed. Replace the hydraulic lock relay.
STOP
• NOT OK - The voltage does not measure 18 VDC to 28 VDC when the lever is in the
RELEASED position and the voltage does not measure approximately 0.0 ± 0.5 VDC in the
LOCKED position. The voltage is not correct. The machine harness or the neutral start switch
has failed. Proceed to Test Step 6.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the "neutral start" switch.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 6
C. At the machine harness connector of the "neutral start" switch, measure the resistance between
contacts B and C while the hydraulic lock lever is moved from the LOCKED position to the
RELEASED position.
Expected Result:
The resistance is less than 5 ohms when the lever is in the RELEASED position. The resistance is
greater than 5000 ohms when the lever is in the LOCKED position.
Results:
• OK - The resistance is less than 5 ohms when the lever is in the RELEASED position. The
resistance is greater than 5000 ohms in the LOCKED position. The resistance is correct.
Repair: The machine harness is open. Repair the machine harness or replace the machine
harness.
STOP
• NOT OK - The resistance does not measure less than 5 ohms when the lever is in the
RELEASED position. The resistance is not greater than 5000 ohms in the LOCKED position.
The resistance is not correct.
Repair: The neutral start switch has failed. Replace the neutral start switch.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:38:26 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i02365054
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Illustration 1 g01210462
This diagnostic code is associated with the Hydraulic Lock Solenoid. The FMI 06 means that the
machine ECM determined that the current is above normal.
When this diagnostic code occurs, a warning is displayed on the Monitoring System and the machine
ECM disables the hydraulic system.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear the diagnostic codes when the original diagnostic code has been corrected.
B. Turn the disconnect switch and the key start switch to the ON position. Do NOT start the
engine.
Expected Result:
Results:
• OK - The diagnostic code changed on the Monitoring System. The circuit is correct.
STOP
• NOT OK - The diagnostic code did not change on the Monitoring System. The diagnostic code
remains active. Proceed to Test Step 2.
B. Disconnect the machine harness connectors J1 and J2 from the machine ECM.
D. Place a jumper between contacts 3 (wire A588-GN) and 5 (wire E564-PK) of the hydraulic lock
on solenoid.
E. Place the hydraulic lock lever in the locked position (the down position).
F. At the machine harness connector J2 for the machine ECM, measure the resistance between
contact J2-27 (wire E997-BR) and all sources of ground.
Expected Result:
Results:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
• OK - The resistance measurements are greater than 5000 ohms. The resistance is correct.
Proceed to Test Step 3.
• NOT OK - The resistance is less than 5000 ohms. The solenoid energizer circuit is shorted to
+battery.
STOP
C. Turn the disconnect switch and the key start switch to the ON position.
D. Clear all active diagnostic codes from the Monitoring System by pressing the OK key that is
located on the keypad.
Expected Result:
The diagnostic code for the solenoid is not present. The diagnostic information may also be viewed
with the ET.
Results:
• OK - The diagnostic code for the solenoid is not present. The diagnostic code was probably
caused by a poor electrical connection or an open at one of the harness connectors that was
disconnected and re connected. Resume normal machine operation.STOP
• NOT OK - The diagnostic code for the solenoid is still present. The diagnostic code has not
been corrected. The machine ECM has failed. It is unlikely that the ECM has failed. Exit this
procedure and perform this diagnostic code procedure again.
Repair: If the cause of this diagnostic code is not found, replace the machine ECM. See
Testing And Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:38:43 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756680
Illustration 1 g02026254
This diagnostic code is recorded when the Machine ECM reads the signal voltage of the pressure
sensor as being too high.
• The sensor supply or the ground circuit in the machine harness is open.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
• The signal circuit in the machine harness is open or the sensor is disconnected.
A. Turn the disconnect switch and the key start switch to the ON position.
C. Observe the status of the diagnostic code. Then, disconnect the machine harness from the
sensor.
Expected Result:
If the sensor is not the cause of the diagnostic code, the diagnostic code remains present. If the sensor
has failed, the diagnostic code is NO longer present.
Results:
• OK - The diagnostic code remains present. The sensor has not failed. The machine harness or
the Machine ECM may have failed. Proceed to Test Step 2.
• NOT OK - The diagnostic code is NO longer present. The machine harness is correct and the
Machine ECM is operating properly. The sensor has failed.
Repair: Replace the sensor. Verify that the new sensor corrects the problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the J1 connector for the ECM, measure the resistance from contact J1-37 (wire H446-PK) to
all other J1 and J2 contacts.
Expected Result:
Results:
• YES - The resistance is greater than 5 ohms. The harness is correct. Proceed to Test Step 3.
• NO - The resistance is not greater than 5 ohms for each measurement. There is a short in the
harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Repair: The short is in the wire with the low resistance measurement. Repair the harness or
replace the harness.
STOP
B. The disconnect switch and the key start switch remain in the OFF position.
C. The machine harness connectors remain disconnected from the Machine ECM.
D. At the J1 connector for the ECM, measure the resistance between the return contact J1-18 (wire
A209-BK) and contact 2 (wire A209-BK) at the sensor.
Expected Result:
Results:
• YES - The resistance is less than 5 ohms. The harness resistance is correct. Proceed to Test
Step 4.
• NO - The resistance is greater than 5 ohms. The return circuit of the harness has failed.
Repair: There is an open in the return wire (A209-BK). Repair the machine harness or replace
the machine harness.
STOP
A. Inspect the contacts and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The diagnostic code is NO longer active. The initial diagnostic code was probably
caused by a poor electrical connection or a short at one of the harness connectors that was
disconnected and reconnected. Resume normal machine operation.STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
• NO - The diagnostic code remains active. The Machine ECM has failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. Also, recheck if the indicator is illuminated for this diagnostic code. If the
cause of the diagnostic code is not found, replace the Machine ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:38:59 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756743
Illustration 1 g02026254
This diagnostic code is recorded when the Machine ECM reads the signal voltage of the pressure
sensor as being too low.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
A. Turn the disconnect switch and the key start switch to the ON position.
C. Observe the status of the diagnostic code. Disconnect the machine harness from the sensor.
Expected Result:
The diagnostic code will remain active if the sensor is not the cause of the problem. The sensor is the
cause of the problem if the diagnostic code is NO longer active.
Results:
• OK - The diagnostic code remains active. The sensor has not failed. The machine harness may
have failed or the Machine ECM may have failed. Proceed to Test Step 2.
Repair: The machine harness and the Machine ECM are operating properly. The sensor has
failed. Replace the sensor.
STOP
B. Turn the key start switch and the disconnect switch to the OFF position.
C. Disconnect the machine harness connector J1 and J2 from the Machine ECM.
D. At the J1 machine harness connector, measure the resistance from contact J1-37 (H446-PK) to
all source of ground.
Expected Result:
Results:
• OK - The resistance is greater than 5 ohms. The machine harness is correct. Proceed to Test
Step 3.
Repair: There is a short in the machine harness. The short is between the signal circuit (wire
H446-PK) and the circuit with the low resistance measurement. Repair the machine harness or
replace the machine harness.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
STOP
Expected Result:
Results:
• YES - The diagnostic code is NO longer active. The diagnostic code does not exist at this time.
The initial diagnostic code was probably caused by a poor electrical connection and/or a short
at one of the harness connectors that was disconnected and then reconnected. Resume normal
machine operation.STOP
• NO - The diagnostic code has not been corrected. The Machine ECM has failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
diagnostic code procedure again. Replace the ECM if the cause of the diagnostic code is not
found. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:39:16 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i04170113
Illustration 1 g02026254
This diagnostic code is for the Boom"Overload Pressure" sensor. An FMI 08 diagnostic code means
the machine ECM has determined the sensor output signal has an abnormal frequency, pulse width, or
period.
• Failed sensor.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1178 FMI 08 is
still active, before performing the following procedures.
System Response:
Test Step 1. CHECK THE SENSOR, THE ECM, AND THE MACHINE HARNESS.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connector from the Boom"Overload Pressure" sensor.
C. In the harness connector for the sensor, place a jumper wire between the contact for terminal C
(wire H446-PK) and the contact for terminal B (wire A209-BK) in the sensor connector.
D. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 1178 FMI 08 diagnostic code remains active. The sensor is not causing the
problem. Go to Test Step 2.
• NO - The CID 1178 FMI 08 diagnostic code is no longer active. The diagnostic code has been
replaced by an active CID 1178 with a different FMI code. The sensor has failed.
Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. Disconnect both the J1 and J2 harness connector from the machine ECM.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
E. At the ECM J1 harness connector, measure the resistance between contact J1-37 (wire H446-
PK) and frame ground.
F. Again at the ECM J1 harness connector, measure the resistance between contact J1-37 (wire
H446-PK) and all of the other contacts that are used in both the J1 and J1 ECM harness
connectors.
Expected Result:
Results:
• YES - All resistance readings are greater than 5000 ohms. Go to Test Step 3.
• NO - All resistance readings are not greater than 5000 ohms. There is a short circuit in the
machine harness.
Go to Test Step 3.
A. Reconnect all disconnected machine harness connectors. Make sure that all the connectors are
fully seated. Observe that the clips for each connector are securely fastened.
B. Turn the key start switch and the disconnect switch to the ON position.
Expected Result:
Results:
• YES - The CID 1178 FMI 08 diagnostic code is no longer active and does not exist at this time.
Repair: The cause for the diagnostic code has been corrected. Return the machine back to
normal operations.
STOP
• NO - The CID 1178 FMI 08 diagnostic code is still active. The problem has not been corrected.
The ECM may have failed.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the sensor circuit.Perform a "wiggle test" on the sensor circuit
of the machine wiring harness, using the Caterpillar Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem was again not found, and the original code is still active, the machine ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:39:29 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756751
Illustration 1 g02026360
This diagnostic code is associated with the "Relief-2 Check Solenoid (attachment)". The FMI 03
diagnostic code means that the Machine ECM has determined that the voltage is above normal.
• The solenoid energizer circuit of the modulating valve is shorted to the +battery circuit.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1522 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE
+BATTERY CIRCUIT
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-30
(wire K877-BU) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-30 (K877-BU) and the circuit that has a low
resistance measurement.
STOP
A. Inspect the contacts and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• YES - The CID 1522 FMI 03 diagnostic code is active. The problem has not been corrected.
The Machine ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1522 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:39:45 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756769
Illustration 1 g01247937
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
This diagnostic code is associated with the "Relief-2 Check Solenoid (attachment)". The FMI 05
diagnostic code means that the Machine ECM has determined that the current is below normal.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1522 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
K877-BU) to contact 2 (wire 235-BK).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous test remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-30 (wire K877
-BU) to contact J1-2 (wire 235-BK).
E. At the machine harness connector, measure the resistance from signal contact J2-30 (wire K877
-BU) to contact J1-14 (wire 235-BK).
Expected Result:
Results:
• OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test
Step 3.
• NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire K877-BU or in wire 235-BK of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1522 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
• NO - The CID 1522 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:40:00 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756775
Illustration 1 g02026360
This diagnostic code is associated with the "Relief-2 Check Solenoid (attachment)". The FMI 06
diagnostic code means that the Machine ECM has determined that the current of the solenoid is above
normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1522 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 1522 FMI 06 diagnostic code changes to a CID 1522 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 1522 FMI 06 diagnostic code changes to a CID 1522 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 1522 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-30 (wire
K877-BU) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-30 (wire K877-BU) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1522 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1522 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:40:13 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756786
Illustration 1 g02026385
This diagnostic code is associated with the "Relief-1 Check Solenoid (attachment)". The FMI 03
diagnostic code means that the Machine ECM has determined that the voltage is above normal.
• The energizer circuit of the solenoid for the modulating valve is shorted to the +battery circuit.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1523 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE
+BATTERY CIRCUIT
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the Machine ECM, measure the resistance from contact
J2-29 (wire K876-BR) to all contacts that are used in the machine harness connectors for the
Machine ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-29 (K876-BR) and the circuit that has a low
resistance measurement.
STOP
A. Inspect the contacts and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• YES - The CID 1523 FMI 03 diagnostic code is active. The problem has not been corrected.
The ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1523 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:40:29 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756793
Illustration 1 g02026385
This diagnostic code is associated with the "Relief-1 Check Solenoid (attachment)". The FMI 05
diagnostic code means that the Machine ECM has determined that the current is below normal.
• The energizer circuit of the modulating valve for the solenoid is open.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1523 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
K876-BR) to contact 2 (wire 235-BK).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous test remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-29 (wire K876
-BR) to contact J1-2 (wire 235-BK).
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
E. At the machine harness connector, measure the resistance from signal contact J2-29 (wire K876
-BR) to contact J1-14 (wire 235-BK).
Expected Result:
Results:
• OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test
Step 3.
• NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire K876-BR or in wire 235-BK of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1523 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The Machine ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1523 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:40:47 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756795
Illustration 1 g02026385
This diagnostic code is associated with the "Relief-1 Check Solenoid (attachment)". The FMI 06
diagnostic code means that the Machine ECM has determined that the current of the solenoid is above
normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1523 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 1523 FMI 06 diagnostic code changes to a CID 1523 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 1523 FMI 06 diagnostic code changes to a CID 1523 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 1523 FMI 06diagnostic code remains active. Proceed to Test Step 2.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-29 (wire
K876-BR) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-29 (wire K876-BR) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1523 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1523 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:41:05 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756796
Illustration 1 g02026391
This diagnostic code is associated with the "Travel Straight" Solenoid. The FMI 03 diagnostic code
means that the Machine ECM has determined that the voltage is above normal.
• The solenoid energizer circuit of the modulating valve is shorted to the +battery circuit.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1525 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE
+BATTERY CIRCUIT
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-1 (wire
M740-PK) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-1 (M740-PK) and the circuit that has a low resistance
measurement.
STOP
A. Inspect the contacts and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• YES - The CID 1525 FMI 03 diagnostic code is active. The problem has not been corrected.
The Machine ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1525 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:41:20 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756801
Illustration 1 g02026391
This diagnostic code is associated with the "Travel Straight" Solenoid. The FMI 05 diagnostic code
means that the Machine ECM has determined that the current is below normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1525 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
M740-PK) to contact 2 (wire 235-BK).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous test remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-1 (wire M740-
PK) to contact J1-2 (wire 235-BK).
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
E. At the machine harness connector, measure the resistance from signal contact J2-1 (wire M740-
PK) to contact J1-14 (wire 235-BK).
Expected Result:
Results:
• OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test
Step 3.
• NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire M740-PK or in wire 235-BK of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1525 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The Machine ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1525 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:41:37 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03756804
Illustration 1 g02026391
This diagnostic code is associated with the "Travel Straight" Solenoid. The FMI 06 diagnostic code
means that the ECM has determined that the current of the solenoid is above normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1525 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 1525 FMI 06 diagnostic code changes to a CID 1525 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 1525 FMI 06 diagnostic code changes to a CID 1525 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 1525 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-1 (wire
M740-PK) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-1 (wire M740-PK) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1525 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The Machine ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1525 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:42:02 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434610
Illustration 1 g02153156
This diagnostic code is associated with the Flow Limit Pressure solenoid. An FMI 03 diagnostic code
means that Machine ECM has determined the voltage in the solenoid circuit is above normal.
• The Flow Limit Pressure solenoid energize circuit has shorted to a voltage source.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1590 FMI 03 is
still active, before performing the following procedures.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the machine harness connector from the Flow Limit Pressure solenoid.
C. At the harness connector for the solenoid, place a jumper wire from contact 1 (M737-WH) to
contact 2 (M739-YL) on the connector.
D. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Expected Result:
Results:
• YES - The CID 1590 FMI 03 diagnostic code remains active. The jumper wire did not change
the code. The solenoid is NOT the cause of the problem.
Repair: The machine harness has failed, or the ECM may have failed.
Go to Test Step 2.
• NO - The CID 1590 FMI 03 code is no longer active, and has been replaced by an active CID
1590 FMI 06 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness connections, are correct. The solenoid has failed.Perform
Test Step 1 again, to verify the solenoid failure. Replace the solenoid.
Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
B. The harness connector remains disconnected from the Flow Limit Pressure solenoid.
D. Disconnect the J1 and J2 machine harness connectors from the Machine ECM.
E. At the ECM J2 harness connector, measure the resistance from contact J2-9 (M737-WH) to all
of the other contacts that are used in the machine harness connectors for the ECM.
Expected Result:
Results:
• YES - Each resistance is more than 5000 ohms. The machine harness is correct. Go to Test
Step 3.
• NO - Each resistance is NOT more than 5000 ohms. There is a short in the harness. The short is
between contact J2-9 (M737-WH) and the circuit with the low resistance.
Go to Test Step 3.
B. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are fastened securely.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1590 FMI 03 diagnostic code is no longer active. The code does not exist at
this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
• NO - The CID 1590 FMI 03 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Cat® Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem has NOT been found, and this diagnostic code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace ".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:42:17 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434616
Illustration 1 g02153156
This diagnostic code is associated with the Flow Limit Pressure solenoid. An FMI 05 diagnostic code
means the ECM has determined the current of the solenoid circuit is below normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1590 FMI 05 is
still active, before performing the following procedures.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the machine harness connector from the Flow Limit Pressure solenoid.
C. At the harness connector for the solenoid, place a jumper wire from contact 1 (M737-WH) to
contact 2 (M739-YL) on the connector.
D. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Expected Result:
Results:
• YES - The CID 1590 FMI 05 code remains active. The jumper wire did not change the code.
The solenoid is NOT the cause of the problem.
Repair: The machine harness has failed, or the ECM may have failed.
Go to Test Step 2.
• NO - The CID 1590 FMI 05 code is NOT active, and has been replaced by an active CID 1590
FMI 06 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness connections, are correct. The solenoid has failed. Perform
Test Step 1 again, to verify the solenoid failure. Replace the solenoid.
Go to Test Step 3.
A. Turn the key start switch and the disconnect switch to the OFF position.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
B. The jumper wire that was placed into the Flow Limit Pressure solenoid harness connector
during Test Step 1 remains in place.
D. At the ECM J2 harness connector, measure the resistance from contact J2-9 (M737-WH) to
contact J2-35 (M739-YL) on the connector.
Expected Result:
Results:
• YES - The resistance is less than 5.0 ohms. The machine harness is correct. Go to Test Step 3.
• NO - The resistance is NOT less than 5.0 ohms. There is an open in the harness.
Repair: The open is in wire M737-WH or in wire M739-YL of the machine harness. Repair, or
replace, the harness.
Go to Test Step 3.
B. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are securely fastened.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1590 FMI 05 diagnostic code is no longer active. The code does not exist at
this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
• NO - The CID 1590 FMI 05 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Cat® Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 4 again. If the
problem has NOT been found, and this diagnostic code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:42:32 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i05434619
Illustration 1 g02153156
This diagnostic code is associated with the Flow Limit Pressure solenoid. An FMI 06 diagnostic code
means the ECM has determined the current of the solenoid circuit is above normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes now, but clear those codes after the original diagnostic code has been corrected.
Note: Poor connections are often the cause of a problem in electrical circuits. Before performing
this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the
connections in the circuit are clean, secure, and in good condition. If a problem is found with
any of the connections: correct the problem and verify that diagnostic code CID 1590 FMI 03 is
still active, before performing the following procedures.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID, THE ECM, AND THE CIRCUIT CONNECTIONS IN
THE MACHINE HARNESS.
A. Turn the disconnect switch and the key start switch to the OFF position.
B. Disconnect the machine harness connector from the Flow Limit Pressure solenoid.
C. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Expected Result:
Results:
• YES - The CID 1590 FMI 06 code remains active. Disconnecting the solenoid did not change
the code. The solenoid is NOT the cause of the problem.
Repair: The machine harness has failed, or the ECM may have failed.
Go to Test Step 2.
• NO - The CID 1590 FMI 06 diagnostic code is no longer active, and has been replaced by an
active CID 1590 FMI 05 diagnostic code. The ECM has detected a valid diagnostic code.
Repair: The ECM, and the harness connections, are correct. The solenoid has failed.Perform
Test Step 1 again, to verify the solenoid failure. Replace the solenoid.
Go to Test Step 3
Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO
GROUND.
A. Turn the key start switch and the disconnect switch to the OFF position.
B. The harness connector remains disconnected from the Flow Limit Pressure solenoid.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
C. Disconnect the J1 and J2 machine harness connectors from the Machine ECM.
D. At the ECM J2 harness connector, measure the resistance from the signal contact J2-9 (wire
M737-WH) to all of the other contacts used in the machine harness connectors for the ECM.
Expected Result:
Results:
• YES - Each resistance is more than 5000 ohms. The harness is correct. Go to Test Step 3.
• NO - Each resistance is NOT more than 5000 ohms. There is a short in the harness. The short is
between J2-9 (M737-WH) and the circuit with the low resistance.
Go to Test Step 3.
A. Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that
the clips for each connector are securely fastened.
B. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1590 FMI 06 diagnostic code is no longer active. The code does not exist at
this time.
Repair: The cause for the diagnostic code appears to have been corrected. Return the machine
back to normal operations.
STOP
• NO - The CID 1590 FMI 06 diagnostic code is still active. The problem has NOT been
corrected.
Repair: If you have not inspected the harness connectors in a previous Test Step, do that now.
Clean the contacts of the harness connectors. Check the wires for damage to the insulation
caused by excessive heat, battery acid, or chafing.Perform a 45 N (10 lb.) pull test on each of
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
the wires that are associated with the solenoid circuit.Perform a "wiggle test" on the solenoid
circuit of the machine wiring harness, using the Cat® Electronic Technician service tool. The
"wiggle test" can be used to detect open or shorted connections in the machine wiring
harness.Reconnect all harness connectors. Make sure that the connectors are fully seated.
Observe that the clips for each connector are fastened. Perform Test Step 3 again. If the
problem has NOT been found, and the original code is still active, the ECM may have
failed.Prior to replacing an ECM, always contact your Dealership Technical Communicator for
possible consultation with Caterpillar, or with the Dealer Solutions Network. This consultation
may greatly reduce repair time. If the ECM needs to be replaced, see Testing and Adjusting,
"Electronic Control Module (ECM) - Replace".
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:42:43 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03757890
Illustration 1 g02026777
This diagnostic code is associated with the "Attachment Valve #1 Extend Pressure" Solenoid. The
FMI 03 diagnostic code means that the ECM has determined that the voltage is above normal.
• The energizer circuit of the solenoid for the modulating valve is shorted to the +battery circuit.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1593 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE
+BATTERY CIRCUIT
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the Machine ECM, measure the resistance from contact
J2-38 (wire K856-PU) to all contacts that are used in the machine harness connectors for the
Machine ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-38 (K856-PU) and the circuit that has a low
resistance measurement.
STOP
A. Inspect the contacts and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• YES - The CID 1593 FMI 03 diagnostic code is active. The problem has not been corrected.
The Machine ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1593 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:42:55 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758049
Illustration 1 g02026777
This diagnostic code is associated with the "Attachment Valve #1 Extend Pressure" Solenoid. The
FMI 05 diagnostic code means that the Machine ECM has determined that the current is below
normal.
• The energizer circuit of the solenoid for the modulating valve is open.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1593 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
K856-PU) to contact 2 (wire K868-BR).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous test remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-38 (wire K856
-PU) to contact J2-19 (wire K868-BR).
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test
Step 3.
• NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire K856-PU or in wire K868-BR of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1593 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The Machine ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1593 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:43:09 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758072
Illustration 1 g02026777
This diagnostic code is associated with the "Attachment Valve #1 Extend Pressure" solenoid. The
FMI 06 diagnostic code means that the ECM has determined that the current of the solenoid is above
normal.
• The energizer circuit of the solenoid for the modulating valve is shorted to ground.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1593 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 1593 FMI 06 diagnostic code changes to a CID 1593 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 1593 FMI 06 diagnostic code changes to a CID 1593 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 1593 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-38 (wire
K856-PU) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-38 (wire K856-PU) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1593 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1593 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:43:31 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758079
Illustration 1 g02026896
This diagnostic code is associated with the "Attachment Valve #2 Extend Pressure" Solenoid. The
FMI 03 diagnostic code means that the Machine ECM has determined that the voltage is above
normal.
• The energizer circuit of the solenoid for the modulating valve is shorted to the +battery circuit.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1594 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE
+BATTERY CIRCUIT
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-40
(wire K857-WH) to all contacts that are used in the machine harness connectors for the
Machine ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-40 (K857-WH) and the circuit that has a low
resistance measurement.
STOP
A. Inspect the contacts and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• YES - The CID 1594 FMI 03 diagnostic code is active. The problem has not been corrected.
The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1594 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:43:45 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758092
Illustration 1 g02026896
This diagnostic code is associated with the "Attachment Valve #2 Extend Pressure" Solenoid. The
FMI 05 diagnostic code means that the Machine ECM has determined that the current is below
normal.
• The energizer circuit of the solenoid for the modulating valve is open.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 4
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1594 FMI 05 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
B. Disconnect the solenoid with the active diagnostic code from the machine harness.
C. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire
K857-WH) to contact 2 (wire K868-BR).
Expected Result:
Results:
• YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code.
Proceed to Test Step 2.
Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to
verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the
problem.
STOP
A. Turn the key start switch and the disconnect switch to the OFF position.
C. The jumper wire that was installed in the previous test remains in place.
D. At the machine harness connector, measure the resistance from signal contact J2-40 (wire K857
-WH) to contact J2-19 (wire K868-BR).
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 4
Expected Result:
Results:
• OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test
Step 3.
• NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not
correct. There is an open circuit in the machine harness.
Repair: The open is in wire K857-WH or in wire K868-BR of the machine harness. Repair the
machine harness or replace the machine harness.
STOP
A. Inspect the contacts of the harness connectors and clean the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1594 FMI 05 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure
again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1594 FMI 05 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 4
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:43:59 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758115
Illustration 1 g02026896
This diagnostic code is associated with the "Attachment Valve #2 Extend Pressure" solenoid. The
FMI 06 diagnostic code means that the Machine ECM has determined that the current of the solenoid
is above normal.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1594 FMI 06 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
A. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
C. Disconnect the solenoid with the active diagnostic code from the machine harness.
Expected Result:
The CID 1594 FMI 06 diagnostic code changes to a CID 1594 FMI 05 diagnostic code when the
solenoid is disconnected.
Results:
• YES - The CID 1594 FMI 06 diagnostic code changes to a CID 1594 FMI 05 diagnostic code
when the solenoid is disconnected. The circuit is correct.
Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify
the solenoid failure. Replace the solenoid.
STOP
• NO - The CID 1594 FMI 06 diagnostic code remains active. Proceed to Test Step 2.
A. Turn the key start switch and the disconnect switch to the OFF position.
D. At the machine harness connector, measure the resistance from the signal contact J2-40 (wire
K857-WH) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 3.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-40 (wire K857-WH) and the circuit with the low
resistance measurement.
STOP
A. Inspect the harness connectors and clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
Results:
• YES - The CID 1594 FMI 06 diagnostic code is active. The diagnostic code has not been
corrected. The ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1594 FMI 06 diagnostic code is not active. The diagnostic code does not exist at
this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP
Copyright 1993 - 2017 Caterpillar Inc. Sun Apr 23 08:44:12 UTC+0700 2017
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 1 of 3
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320D EXCAVATOR BZP
Configuration: 320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine
Troubleshooting
320D, 320D2, 321C, 321D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 336D2,
340D, 340D2 and 340D2 Excavators, 324D FM Forest Machine and 323D MHPU, 324D
MHPU, 325D MHPU, 329D MHPU, 330D MHPU and 336D MHPU Mobile Hydraulic Power
Units Machine Electronic Control System
Media Number -RENR9848-24 Publication Date -01/04/2014 Date Updated -30/04/2014
i03758181
Illustration 1 g02026953
This diagnostic code is associated with the "Attachment Valve #3 Extend Pressure" Solenoid. The
FMI 03 diagnostic code means that the Machine ECM has determined that the voltage is above
normal.
• The energizer circuit of the solenoid for the modulating valve is shorted to the +battery circuit.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 3
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic
codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure
that the diagnostic code of CID 1595 FMI 03 is active before performing this procedure.
Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.
System Response:
When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.
Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE
+BATTERY CIRCUIT
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the Machine ECM.
C. At the machine harness connector for the ECM, measure the resistance from contact J2-42
(wire K858-YL) to all contacts that are used in the machine harness connectors for the Machine
ECM.
Expected Result:
Results:
• OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct.
Proceed to Test Step 2.
• NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the
machine harness. The short is between J2-42 (K858-YL) and the circuit that has a low
resistance measurement.
STOP
A. Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
C. Turn the disconnect switch and the key start switch to the ON position.
Expected Result:
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 4/23/2017
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 3
Results:
• YES - The CID 1595 FMI 03 diagnostic code is active. The problem has not been corrected.
The Machine ECM may have failed.
Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this
procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing
and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP
• NO - The CID 1595 FMI 03 diagnostic code is not active. The problem does not exist at this
time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
short at one of the harness connectors that was disconnected and reconnected. Resume normal
machine operation.
STOP