Dia in MM Pipe Thick in MM Insulatio N Thick in MM

The document specifies chilled water pipes made of mild steel up to 150mm diameter conforming to IS 1239 and IS 3589 for larger diameters. The pipes will be insulated with polyurethane foam of 40±2 kg/m3 density and covered with 0.5mm thick GI cladding. Insulation thickness varies from 30mm to 75mm depending on pipe diameter. Insulation can be supplied in pre-formed pipe sections or injected on site. Quantities of insulated pipes of various diameters are also provided.

Uploaded by

lmsanthosh kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views2 pages

Dia in MM Pipe Thick in MM Insulatio N Thick in MM

The document specifies chilled water pipes made of mild steel up to 150mm diameter conforming to IS 1239 and IS 3589 for larger diameters. The pipes will be insulated with polyurethane foam of 40±2 kg/m3 density and covered with 0.5mm thick GI cladding. Insulation thickness varies from 30mm to 75mm depending on pipe diameter. Insulation can be supplied in pre-formed pipe sections or injected on site. Quantities of insulated pipes of various diameters are also provided.

Uploaded by

lmsanthosh kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Chilled water Mild steel pipes (Heavy Class) with all necessary

fittings like bends, elbows, tees, reducers, hanger, supports,etc


1 and shall be clause B/Calss C as per IS 1239 upto 150mm dia
and as per IS 3589. for 200mm dia & above.

Insulation of Polyurethane foam pipe sections with density of


40±2 kg/m3 and finally finished with G.I. Colour Coated sheet
Cladding of 26 G (0.5 mm)

Dia in Pipe thick nInsulatio


thick in
mm in mm mm
a 15 - 30 RMT
b 20 - 30 RMT
c 25 - 30 RMT
d 32 - 40 RMT
e 40 - 40 RMT
f 50 - 40 RMT
g 65 - 40 RMT
h 80 - 40 RMT
i 100 - 40 RMT
j 125 - 40 RMT
k 150 - 50 RMT
l 200 5.0 50 RMT
m 250 5.0 50 RMT
n 300 5.6 50 RMT
o 350 5.6 50 RMT
p 400 6.3 50 RMT
q 450 6.3 50 RMT
r 500 6.3 50 RMT
s 600 6.3 75 RMT
Insulation Offer shall be in
two options as below:

Option 1 : PUF Insulation by


pipe sections.

Option 2 : PUF Insulation